Alumasc Exteriors - LCC Socketless Cast Iron

Page 1

Engineered Drainage Harmer LCC

7/11/02

10:45 am

Page 1

Engineered Drainage Systems

Uniclass

G5811

CI/SfB (52.3) October 2002

Harmer Socketed Soil and Waste Systems

Harmer LCC


Engineered Drainage Harmer LCC

7/11/02

10:45 am

Page 2

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Contents

Contents page

Introduction to Harmer LCC

3

Pipe Dimensions and Weights

4

Harmer LCC Pipes and Fittings â–

Pipes and Fittings

Imperial Conversion Table

2

Alumasc Technical Helpline 01744 648400

6

19


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 3

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Introduction

Harmer LCC Socketed Soil and Waste Systems Introduction Harmer LCC is a traditional socketed cast iron pipe and fittings system manufactured to original imperial dimensions. It has been created specifically for use in building refurbishment and historic building contracts where there is a need to faithfully reproduce period detail. Alumasc has taken the original processes for the casting of iron, and combined them with modern manufacturing techniques to produce a product fully attuned to today’s refurbishment requirements.

Features Harmer LCC incorporates all the inherent characteristics of cast iron, plus dimensional accuracy and a consistent standard of finish for the final site installation. An extensive range of fittings and accessories provides great flexibility in installation, while special detailing requirements can be catered for through Alumasc’s fabrication and pattern making workshops. Alumasc has also perfected the welding of cast iron, so that fittings or offsets to suit a particular situation can be specially fabricated where the alternative of making a pattern would not be economic.

Key Benefits ■ Ideal for itemised replacement of existing LCC systems

General Description

Imperial Dimensions

Harmer LCC soil and waste pipes and fittings are factory-dipped in bitumen in accordance with BS 416. Where gloss painting is required, it is advisable to contact Alumasc Technical Services on 01744 648400.

All products are made to the original imperial dimensions. This ensures a compatible interchange between old and new pipes and fittings and makes it more likely that, where an existing installation is being repaired or replaced, the original fixing holes can be re-used.

Standards

Pipe Fixing and Support

Harmer LCC waste pipes and fittings comply with the requirements of BS 416: Discharge, ventilating pipes and fittings, sand cast or spun in cast iron, Part 1, 1990. Harmer LCC systems also comply with the relevant sections of the Building Regulations throughout the United Kingdom.

Holderbats for plugging and screwing to walls are available. Bobbins should be used to pack out the holderbat to give a 32mm painting gap for pipes up to 75mm (3") diameter, and 38mm for the 88mm (3 1/2") and 100mm (4”) diameter pipes. For fixing centres reference should be made to BS 8000: Maximum distance between sanitary pipe supports, Table 1.

Finishes

Installation BS 8000: Workmanship on building sites, Part 13, Code of practice for above ground drainage and sanitary appliances, 1989 is applicable.

Suitability Cast iron should not be used for conveying acid wastes or laid unprotected in any soil conditions where corrosion could occur.

On-site Storage To avoid accidental damage to collars or pipe ends, pipes should be stored horizontally, blocked up clear of the ground and preferably under cover.

Pipe Joints Pipe joints should be made using a caulking of 6mm diameter yarn, now available only in glass fibre instead of the traditional tarred yarn, with a minimum 38mm thickness of lead wool, well compacted.

Testing The Building Regulations 1991, Requirement H1, Approved Document paragraph 1.7(a) requires that all the pipes, fittings and joints should be capable of withstanding an air or smoke test of at least 38mm gauge, for 3 minutes.

■ Manufactured to original imperial dimensions ■ Supplied ready painted ■ Comprehensive range of fittings ■ Unique specials manufacture and fabrication

Alumasc Technical Helpline 01744 648400

3


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 4

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Pipe Dimensions and Weights

Pipes f Manufacturing dimensions

e b a

v h d

g k

j u c

100mm Dia Pipe a Internal diameter 100 b External diameter 114 c Thickness 6 d Diameter over spigot bead 104 Socket e Internal diameter 127 f External diameter 136 g Thickness 6 h Internal depth 76 j External diameter over socket beads 133 k Caulking clearance 6 Ears u Length of flange overall 212 v Centre to centre of holes 180

88mm Dia

76mm Dia

63mm Dia

50mm Dia

85 100 6 111

76 88 6 98

60 76 6 85

50 63 6 69

114 130 6 76 146 6

100 117 6 69 139 3

88 104 6 69 114 3

73 88 6 63 100 3

193 161

177 146

161 130

146 114

63mm Dia

50mm Dia

1830 1730 14.0 kg 14.5 kg

1830 1737 11.5 kg 12.0 kg

1219 1130 9.5 kg 10 kg

1219 1137 8 kg 8.5 kg

914 730 7 kg 7.5 kg

914 737 5.7 kg 6.2 kg

610 530 4.7 kg 5.2 kg

610 537 4 kg 4.5 kg

1830 1663 15.3 kg 15.8 kg

1830 1669 12.5 kg 13 kg

Pipe lengths and weights

Single socket

100mm Dia 88mm Dia 76mm Dia 1830 (6ft) pipe Length of pipe overall 1830 1830 1830 Effective length of pipe 1725 1725 1730 Weight of 6' pipe without ears 21.7 kg 19.0 kg 16.7 kg Weight of 6' pipe with ears 22.2 kg 19.5 kg 17.2 kg 1219 (4ft) pipe Length of pipe overall 1219 1219 1219 Effective length of pipe 1125 1125 1130 Weight of 4' pipe without ears 14.5 kg 12.7 kg 11.2 kg Weight of 4' pipe with ears 14.8 kg 13 kg 11.5 kg 914 (3ft) pipe Length of pipe overall 914 914 914 Effective length of pipe 725 725 730 Weight of 3' pipe without ears 10.8 kg 9.5 kg 8.3 kg Weight of 3' pipe with ears 11.3 kg 10 kg 8.8 kg 610 (2ft) pipe Length of pipe overall 610 610 610 Effective length of pipe 525 525 530 Weight of 2' pipe without ears 7.3 kg 6.3 kg 5.5 kg Weight of 2' pipe with ears 7.8 kg 6.8 kg 6 kg Double socket pipe, in 1830 (6ft) overall pipe lengths only 6 ft Double collar – Length of pipe overall 1830 1830 1830 – Effective length of pipe 1650 1650 1663 – Weight without ears 23.7 kg 20.5 kg 18.2 kg – Weight with ears 24.2 kg 21 kg 18.7 kg

Double socket (1830mm pipe length only)

4

Alumasc Technical Helpline 01744 648400


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 5

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Pipes & Fittings

Harmer LCC Pipes & Fittings

Alumasc Technical Helpline 01744 648400

5


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 6

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Pipes and Fittings

Fittings Harmer LCC soil and waste systems comprise a range of pipes available with or without ears, and in five sizes (50, 63, 75, 87 and 100mm diameter), together with a comprehensive range of fittings and fixings.

L3

T 6F

T

5/

4F L3

L3

5/

3F 5/

5/ L3

0/

T

T 2F

T 6F

T

T

4F

L3

L3

L3

L3

0/

0/

3F

T 2F

T

0/

6F

T L2

5/ L2

5/ L2

5/

4F

T 3F

2F

T

L2

0/ L2

L2

5/

6F

T 4F

T

0/

3F

T

0/

2F

L2

0/ L2

Code Ref

T

Pipes with Ears

Pipe Dia mm

50

50

50

50

63

63

63

63

75

75

75

75

87

87

87

87

Pipe Length

610

914

1219

1830

610

914

1219

1830

610

914

1219

1830

610

914

1219

1830

6F

T L4

0/ L4

0/ L4

1. Pipes without Ears If pipes without ears are required, add suffix NE to the order code.

0/

4F

T 3F

T 2F 0/ L4

Code Ref

T

Notes

Pipe Dia mm

100

100

100

100

Pipe Length

610

914

1219

1830

2. Double Collared Pipes If double collared pipes are required with ears, add suffix DCE to the order code. Add suffix DC if no ears required. Only available in 6ft lengths. 3. Pipe nails are available to order. 4. When specifying loose couplings, slip couplings and access pipes with ears, quote the full product code suffixed with /E.

Built-in Holderbats

50

88

100

Note: Cast iron bobbins are available spacing from 13mm to 50mm in 6mm increments.

Note All dimensions are given in millimetres. An imperial to metric conversion table is given on page 19.

6

Alumasc Technical Helpline 01744 648400

50

63

75

T

T

HB L4

0/

5/ L3 88

Note: Cast iron bobbins are available spacing from 13mm to 50mm in 6mm increments.

/S

/S

T

HB

/S

T

HB 0/ L3

L2

0/ L2

Code Ref For Pipe Size

5/

HB

HB

/S

/S

T

I /B HB

0/ L4

L3

L3 75

/B

I

HB 5/

HB 0/

HB 5/ L2

63

/B

I /B

I /B HB 0/ L2

Code Ref For Pipe Size

I

Screw To Wall Cast Iron Holderbats

100


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 7

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Loose Couplings SO C L3 0/ SO C L3 5/ SO C L4 0/ SO C

C SO

5/

b

L2

0/ L2

Code Ref

b

a

Pipe Dia mm

50

63

75

87

100

a

45

45

38

38

35

b

95

95

90

86

80

SO C/ S L3 0/ SO C/ S L3 5/ SO C/ S L4 0/ SO C/ S

a

L2

0/ L2

Code Ref

5/

SO

C/

S

Slip Couplings

Pipe Dia mm

50

63

75

87

100

a

95

95

89

95

79

Blank End BE L4 0/ BE

a

5/

BE

L3

0/ L3

Code Ref Pipe Dia mm

75

87

100

a

76

76

70

SR /2 0 L4 0/ SR /3 0

a

L4

0/ L3

Code Ref

0/

SR

/2

0

Socket Reducer

Pipe Dia mm

75

100

100

a

51

76

51

b

76

76

70

L4 0/ AP

AP L3 0/ AP L3 5/ AP

L2

0/ L2

Code Ref

5/

AP

Access Pipes

Pipe Dia mm

50

63

75

87

a

63

69

69

76

76

b

234

254

266

273

285

c

63

76

88

95

100

a

100 c

b

Note When specifying fittings with ears, quote the full product code suffixed with /E.

Alumasc Technical Helpline 01744 648400

7


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 8

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

a

L2

0/ L2

Code Ref

5/

B/

92

B/ 92 L3 0/ B/ 92 L3 5/ B/ 92 L4 0/ B/ 92

92.5째 Bends

Pipe Dia mm

50

63

75

87

100

a

152

165

174

187

193

b

139

155

161

177

180

c

88

95

104

111

117

c

b

AR 92

92

AL

AR

L4

0/

B/

B/ L4

0/

B/

92

L3

L3

5/

5/

B/

92 B/ 0/

L3

92

AL

AR

AL 92

AR

0/ L3

5/

B/

92

AL

B/

92 B/

L2

5/ L2

L2

0/ L2

Code Ref

0/

B/

B/

92

92

AL

AR

92.5째 Bends with left hand/right hand side access

Pipe Dia mm

50

50

63

63

75

75

87

87

100

100

a

152

152

165

165

174

174

187

187

193

193

b

139

139

155

155

161

161

177

177

180

180

c

88

88

95

95

104

104

111

111

117

117

d

63

63

76

76

88

88

95

95

100

100

a c

d b

B/ 0/

L4

L3

L3

92

H B/

5/

B/ 0/

B/ 5/ L2

92

H 92

H 92

H 92 B/ 0/ L2

Code Ref

H

92.5째 Bends with heel access

Pipe Dia mm

50

63

75

87

100

a

152

165

174

187

193

b

139

155

161

177

180

c

88

95

104

111

117

d

63

76

88

95

100

Note If bends with ears are required, add LE to the order code for left hand side and RE for right hand side bend.

8

Alumasc Technical Helpline 01744 648400

a c

d b


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 9

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

R

BL

a

L4

5/

0/

BL

R BL

L3

0/ L3

Code Ref

R

92.5째 Long Radius Bends

Pipe Dia mm

75

87

100

a

279

292

298

b

292

298

304

c

209

215

222

c

b

2

0/ L4

L3

L3

11 B/

B/ 5/

B/ 0/

B/ 5/ L2

11

2 11

2 11

2 11 B/ 0/ L2

Code Ref

2

112.5째 Bends

Pipe Dia mm

50

63

75

87

100

a

152

165

174

184

193

b

139

155

161

177

180

c

88

95

104

111

120

a c

b

2H 11

0/ L4

L3

L3

B/

B/ 5/

B/ 0/

B/ 5/ L2

11

2H 11

2H 11

2H 11 B/ 0/ L2

Code Ref

2H

112.5째 Bends with heel access

Pipe Dia mm

50

63

75

87

100

a

152

165

174

184

193

b

139

155

161

177

180

c

88

95

104

111

120

d

63

66

73

95

100

a c

d b

Alumasc Technical Helpline 01744 648400

9


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 10

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

5 B/

B/

a

0/

5/

L4

L3

0/ L3

13

13

5 13

5

B/

13

5

B/

13

5/

B/

L2

0/ L2

Code Ref

5

135째 Bends

Pipe Dia mm

50

63

75

87

100

a

127

136

142

171

177

b

142

158

161

161

165

c

88

95

104

111

120

c

b

5H 13

0/

c

Pipe Dia mm

50

63

75

87

100

a

127

136

142

171

177

b

142

158

161

161

165

c

88

95

104

111

120

d

63

66

73

95

100

20

25

20

L4

L3

L3

a

B/

B/ 5/

B/ 0/

B/ 5/ L2

13

5H 13

5H 13

5H 13 B/ 0/ L2

Code Ref

5H

135째 Bends with heel access

d

b

35 DI

0/ L4

0/ L4

a

M/

30 M/

25

DI

M/

20

DI 0/ L4

L4

5/

0/

DI

DI

M/

M/

30

25 M/

5/

L3

L3

L3

5/

DI

M/ DI

M/ DI 0/

L3

L3

5/ L2

Code Ref

0/

DI

DI

M/

M/

20

Diminishing Pieces

Pipe Dia mm

63

75

75

87

87

87

100

100

100

a

69

69

69

76

76

76

76

76

76

100 76

b

304

304

304

304

304

304

304

304

304

304

c

50

50

63

50

63

75

50

63

75

87

b

c

Note If bends with ears are required, add LE to the order code for left hand side and RE for right hand side bend.

10

Alumasc Technical Helpline 01744 648400


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 11

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

/2

/2 L2

5/

OF

OF 5/ L2

50

50

50

50

50

50

50

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

69

69

69

69

69

69

69

69

69

b

241

257

273

304

336

361

400

431

463

257

273

288

320

352

384

415

447

479

Offset

75

112

150

237

300

375

475

554

600

75

112

150

237

300

375

475

554

600

75

75

75

75

75

75

75

87

87

87

87

87

87

87

87

69

69

69

69

69

69

69

69

76

76

76

76

76

76

76

76

76

b

266

282

298

330

361

393

425

457

488

282

298

314

346

377

409

441

473

504

Offset

75

112

150

237

300

375

475

554

600

75

112

150

237

300

375

475

554

600

/2

OF 0/

OF L4

L4

0/

OF

87

/2

1 /2

8 /1

5 /1 L4

L4

0/

0/

OF

OF

/1

9 /0

L4

L4

OF 0/

OF 0/

OF

L4

0/ L4

0/

6 /0

4 /0

3 /0 OF 0/ L4

OF

L3

5/

5/ L3

L3

75

69

4

75

a

2

Pipe Dia mm

Code Ref

4

1 OF

OF 5/

OF

/2

/1

5 /1

2 /1

L3

L3

5/

5/

OF

OF

/0

6 /0

L3

L3

OF 5/

OF L3

5/

4 /0

3 5/

OF L3

L3

L3

/0

4 5/

OF 0/

OF 0/

OF

/2

1 /2

8 /1

5

L3

L3

0/

0/

OF

OF

/1

/1

9

L3

L3

0/

OF 0/

OF 0/

OF

L3

0/ L3

/0

6 /0

4 /0

3 /0 OF 0/ L3

63

8

50

63

9

50

a

2

Pipe Dia mm

Code Ref

4

1

8 /1

5

OF 5/ L2

5/ L2

L2

L2

5/

5/

OF

OF

/1

/1

2

9 /0

6

OF

/0

4

OF 5/ L2

5/ L2

5/ L2

L2

/0

3

OF

/0

4

OF

/2

1

OF 0/

OF 0/ L2

L2

L2

0/

0/

OF

OF

/1

/2

8

5 /1

/1

9

0/

L2

0/ L2

L2

OF

/0

6

OF

/0

4 0/

OF

OF

/0

3 /0

0/

OF

L2

0/ L2

Code Ref

2

112.5째 Swan Necks

Pipe Dia mm

100

100

100

100

100

100

100

100

a

76

76

76

76

76

76

76

76

100 76

b

288

307

323

355

387

419

450

482

514

Offset

75

112

150

237

300

375

475

554

600

a

b

offset

Note If swan necks with ears are required, add LE to the order code for left hand side and RE for right hand side bend.

Alumasc Technical Helpline 01744 648400

11


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 12

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

50

63

/9 0/

L4

L3

75

a

BR

BR

/9

5/

BR

/9 L3

L2

0/

5/

0/

BR

/9 BR Pipe Dia mm

L2

Code Ref

/9

92.5째 Equal Single Branches

87

b

100

a

63

69

69

76

76

b

234

260

285

304

330

c

177

196

212

225

241

d

88

95

111

117

130

c

a

d

75

9

a

A/ BR

BR

0/

5/

L4

L3

L3

63

A/

9 BR

0/

BR 5/ L2

50

A/

9 A/

9 A/ BR 0/ L2

Code Ref Pipe Dia mm

9

92.5째 Equal Single Branches with access

87

b

100

a

63

69

69

76

76

b

234

260

285

304

330

c

177

196

212

225

241

d

88

95

111

117

130

e

146

161

177

190

206

c

e

a

d

63

1 BR

BR

87

L4

0/

5/ L3

L3 75

a

/1

/1

1 BR

0/

BR 5/ L2

0/ 50

/1

1 /1

1 /1 BR Pipe Dia mm

L2

Code Ref

1

112.5째 Equal Single Branches

b

100

a

63

69

69

76

76

b

234

260

285

304

330

c

155

174

184

120

184

d

79

85

100

107

146

c a

d

Note When specifying fittings with ears, quote the full product code suffixed with /E.

12

Alumasc Technical Helpline 01744 648400


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 13

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

63

11 BR

0/

5/

L4

L3

75

a

A/

A/

11

BR

A/

11 0/ L3

5/ L2

0/ 50

BR

A/

11

BR

A/ BR Pipe Dia mm

L2

Code Ref

11

112.5째 Equal Single Branches with Access

87

b

100

a

63

69

69

76

76

b

234

260

285

304

330

c

155

174

184

120

184

d

79

85

100

107

146

e

146

161

177

190

206

c

e

a

d

75

3

a

/1 BR

BR

0/ L4

L3

L3

63

/1

3 5/

BR 0/

BR 5/ L2

50

/1

3 /1

3 /1 BR 0/ L2

Code Ref Pipe Dia mm

3

135째 Equal Single Branches

87

b

100

a

63

69

69

76

76

b

234

260

285

304

330

c

120

130

133

146

146

d

114

130

152

158

184

a c d

13 A/

0/

b

L4

L3

L3

a

BR

BR 5/

BR 0/

BR 5/ L2

A/

13 A/

13 A/

13 A/ BR 0/ L2

Code Ref

13

135째 Equal Single Branches with Access

Pipe Dia mm

50

63

75

87

a

63

69

69

76

100 76

b

234

260

285

304

330

c

120

130

133

146

146

d

114

130

152

158

184

e

146

161

177

190

206

a c

f d

Alumasc Technical Helpline 01744 648400

13


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 14

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

L4

L4

0/

0/

BR

U/

98

97 U/

96

BR

U/

95 0/ L4

L3

L4

5/

0/

BR

BR

BR

U/

97 U/

U/

95

5/ L3

5/ L3

0/ L3

BR

U/

96

BR

U/

95

BR

U/

95

BR

U/

0/

BR

L3

5/ L2

Code Ref

96

92.5째 Unequal Single Branches

Pipe Dia mm

63

75

75

87

87

87

100

100

100

a

69

69

69

76

76

76

76

76

76

100 76

b

260

260

273

266

285

292

279

285

292

304

c

196

196

206

206

209

215

219

209

215

209

d

95

100

104

107

111

117

114

117

123

123

e

63

63

69

63

69

69

63

69

69

76

f

50

50

63

50

63

75

50

63

75

88 a f

b

c e

d

8

7

/9 UA

L4

0/

BR

BR

UA

/9

6 /9 UA

L4

0/

0/

BR

UA BR

L4

0/ L4

5/ L3

5 /9

7 /9 UA

BR

BR

UA

/9

5 UA

L3

5/ L3

L3

5/

BR

UA BR

UA

0/

BR 0/ L3

/9

6 /9

5 /9

5 /9 UA BR 5/ L2

Code Ref

6

92.5째 Unequal Single Branches with Access

Pipe Dia mm

63

75

75

87

87

87

100

100

100

a

69

69

69

76

76

76

76

76

76

100 76

b

260

260

273

266

285

292

279

285

292

304

c

196

196

206

206

209

215

219

209

215

209

d

95

100

104

107

111

117

114

117

123

123

e

63

63

69

63

69

69

63

69

69

76

f

50

50

63

50

63

75

50

63

75

88

g

165

165

170

165

176

187

177

180

182

178

a f

b

c

g

e

d

Note When specifying fittings with ears, quote the full product code suffixed with /E.

14

Alumasc Technical Helpline 01744 648400


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 15

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

8

BR 0/

b

L4

Pipe Dia mm

63

75

75

87

87

100

100

a

69

69

69

76

76

76

76

76

b

276

260

276

263

288

279

288

304

c

187

174

187

180

184

190

184

193

d

104

92

104

98

111

104

114

111

e

63

63

69

63

69

63

69

76

f

50

50

63

50

76

50

76

88

f

U/

U/ BR 0/

L4

L3

a

11

11

11

7

5

7

U/ 5/

5/ L3

L3

BR

BR

U/ BR 5/

U/

11

11

5

6 11 U/

BR L3

L3

0/

0/

5/ L2

Code Ref

BR

BR

U/

U/

11

11

5

5

112.5째 Unequal Single Branches

100 c

e

d

18

a

f

/1

17

UA

/1

b

0/

BR

BR

UA

/1 UA L4

L4

0/

BR 5/ L3

L3

L3

15

17

UA

BR

UA

5/

BR

/1

15 /1

16 /1 UA

5/

BR 0/ L3

L3

L2

Code Ref

0/

5/

BR

BR

UA

UA

/1

/1

15

15

112.5째 Unequal Single Branches with Access

Pipe Dia mm

63

75

75

87

87

100

100

a

69

69

69

76

76

76

76

100 76

b

276

260

276

263

288

279

288

304

c

187

174

187

180

184

190

184

193

d

104

92

104

98

111

104

114

111

e

63

63

69

63

69

63

69

76

f

50

50

63

50

75

50

75

88

g

165

165

165

165

184

174

180

177

c

e

g

d

8 U/

13

13

7

f

a b

BR

U/

13

0/ L4

L4

L3

5/

0/

BR

BR

U/

U/

5/ L3

5

7 13

5 U/

5/ L3

0/ L3

BR

13

6 13

BR

U/ BR

U/

L3

0/

5/ L2

Code Ref

BR

BR

U/

13

13

5

5

135째 Unequal Single Branches

Pipe Dia mm

63

75

75

87

87

100

100

100

a

69

69

69

76

76

76

76

76

b

260

260

280

266

292

279

292

304

c

130

130

130

133

133

139

127

127

d

133

133

133

146

161

152

171

177

e

63

63

69

63

69

63

69

76

f

50

50

63

50

75

50

75

88

e

c

d

Alumasc Technical Helpline 01744 648400

15


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 16

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

38 /1

37

UA

b

0/ L4

0/ L4

5/ L3

f

a

BR

UA

/1

BR

UA BR

BR

5/

/1

35

37 /1

35

L3

L3

5/

UA

/1

36

UA

/1

BR

UA BR 0/

L3

L3

0/

5/ L2

Code Ref

BR

BR

UA

UA

/1

/1

35

35

135째 Unequal Single Branches with Access

Pipe Dia mm

63

75

75

87

87

100

100

100

a

69

69

69

76

76

76

76

76

b

260

260

280

266

292

279

292

304

c

130

130

130

133

133

139

127

127

d

133

133

133

146

161

152

171

177

e

63

63

69

63

69

63

69

76

f

50

50

63

50

75

50

75

88

g

165

165

165

165

184

174

180

177

e

c f d

9

L4

L3

0/

5/

BR

BR

a

D/

D/

9 D/

9

L2

L3

5/

0/

BR

BR

D/

9 D/ BR 0/ L2

Code Ref

9

92.5째 Equal Double Branches

Pipe Dia mm

50

63

75

87

100

a

63

69

69

76

76

b

234

260

285

304

330

c

177

196

212

225

241

d

88

95

111

117

130

b c a d

9A D/

0/ L4

L3

L3

Pipe Dia mm

50

63

75

87

100

a

63

69

69

76

76

b

234

260

285

304

330

c

177

196

212

225

241

d

88

95

111

117

130

e

146

161

177

190

209

Note When specifying fittings with ears, quote the full product code suffixed with /E.

16

a

BR

BR 5/

BR 0/

BR 5/ L2

D/

9A D/

9A D/

9A D/ BR 0/ L2

Code Ref

9A

92.5째 Equal Double Branches with Access

Alumasc Technical Helpline 01744 648400

b c a d


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 17

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

11

BR 0/

5/

L4

L3

0/ L3

5/

a

D/

D/

11

BR

D/

11

BR

D/

11

BR

D/ BR

L2

0/ L2

Code Ref

11

112.5째 Equal Double Branches

Pipe Dia mm

50

63

75

87

100

a

63

69

69

76

76

b

234

260

285

304

330

c

155

174

184

193

209

d

79

85

98

111

120

b a

c e d

A 11

BR 0/

b

L4

L3

L3

a

D/

D/ BR

D/

5/

BR

D/

0/

BR 5/ L2

11

A 11

A 11

A 11 D/ BR 0/ L2

Code Ref

A

112.5째 Equal Double Branches with Access

Pipe Dia mm

50

63

75

87

100

a

63

69

69

76

76

b

234

260

285

304

330

c

155

174

184

193

209

c

a e d

d

79

85

98

111

120

e

146

161

177

190

209

50

63

D/ BR

0/ L4

L3 87

a

13

13 BR

5/

BR L3

75

D/

13 D/

13 D/

0/

BR 5/ L2

L2

Code Ref Pipe Dia mm

0/

BR

D/

13

135째 Equal Double Branches

100

a

63

69

69

76

76

b

234

260

285

304

330

c

120

130

136

146

146

d

114

130

149

158

184

b

a c

d

Alumasc Technical Helpline 01744 648400

17


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 18

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Fittings

Fittings

50

A D/

BR 0/

b

L4

L3

75

a

13

13

A BR 5/

BR 0/ L3

5/ 63

D/

13

A

D/

13

A

D/

13

BR

D/ BR

L2

0/ L2

Code Ref Pipe Dia mm

A

135째 Equal Double Branches with Access

87

100

a

63

69

69

76

76

b

234

260

285

304

330

c

120

130

136

146

146

d

114

130

149

158

184

e

146

161

177

190

209

d

a

Bossed Pipes 00 /2 BP

BP

L4

0/

0/ L4

L4

/1

/1

50

25

00 0/

5/ L3

L3

BP

BP

/1 BP 5/

/2

50

25 /1 BP

L3

L3

5/

0/

0/

BP

BP

/1

/1

50

25

c

L3

Code Ref Pipe Dia mm

75

75

83

83

83

100

100

100

a

76

76

76

76

76

76

76

76

b

381

381

381

381

381

381

381

381

c

139

139

139

139

139

139

139

139

b

SH

a

0/ L4

L3

L3

L2

5/

SH 0/

SH 5/

SH 0/ L2

SH

Shoes

Code Ref Pipe Dia mm

50

63

75

87

100

a

63

69

69

76

76

b

127

149

177

200

228

b

P Traps

18

L4

0/

PT

c

Code Ref Pipe Dia mm

100

a

76

b

136

c

343

a c

Alumasc Technical Helpline 01744 648400

a b


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 19

Engineered Drainage Systems Socketed Soil and Waste Systems Harmer LCC Imperial Conversion Table

Imperial Conversion Table in

mm

1 /8

3.2 6.4 9.5 12.7 15.9 19.1 22.2

1 /4 3 /8 1 /2 5 /8 3 /4 7 /8

1

25.4

11 /8 11 /4 13 /8 11 /2 15 /8 13 /4 17 /8

28.6 31.8 34.9 38.1 41.3 44.5 47.6

2

50.8

21 /8 21 /4 23 /8 21 /2 25 /8 23 /4 27 /8

54.0 57.2 60.3 63.5 66.7 69.9 73.0

3

76.2

31 /8 31 /4 33 /8 31 /2 35 /8 33 /4 37 /8

79.4 82.6 85.7 88.9 92.1 95.3 98.4

4 41 /8 41 /4 43 /8 41 /2 45 /8 43 /4 47 /8

5 51 /8 51 /4 53 /8 51 /2 55 /8 53 /4 57 /8

in 6 61 /8 61 /4 63 /8 61 /2 65 /8 63 /4 67 /8

7 71 /8 71 /4 73 /8 71 /2 75 /8 73 /4 77 /8

8 81 /8 81 /4 83 /8 81 /2 85 /8 83 /4 87 /8

9

mm 152.4 155.6 158.8 161.9 165.1 168.3 171.5 174.6

177.8 181.0 184.2 187.3 190.5 193.7 196.9 200.0

203.2 206.4 209.6 212.7 215.9 219.1 222.3 225.4

228.6

91 /8 91 /4 93 /8 91 /2 95 /8 93 /4 97 /8

231.8 235.0 238.1 241.3 244.5 247.7 250.8

10

254.0

in 12

ft 1

in 0

mm 304.8

121/8 121/4 123/8 121/2 125/8 123/4 127/8

1 1 1 1 1 1 1

0 1 /8 0 1 /4 0 3 /8 0 1 /2 0 5 /8 0 3 /4 0 7 /8

308.0 311.2 314.3 317.5 320.7 323.9 327.0

13

1

1

330.2

131/8 131/4 133/8 131/2 135/8 133/4 137/8

1 1 1 1 1 1 1

1 1 /8 1 1 /4 1 3 /8 1 1 /2 1 5 /8 1 3 /4 1 7 /8

333.4 336.6 339.7 342.9 346.1 349.3 352.4

14

1

2

355.6

141/8 141/4 143/8 141/2 145/8 143/4 147/8

1 1 1 1 1 1 1

2 1 /8 2 1 /4 2 3 /8 2 1 /2 2 5 /8 2 3 /4 2 7 /8

358.8 362.0 365.1 368.3 371.5 374.7 377.8

15

1

3

381.0

151/8 151/4 153/8 151/2 155/8 153/4 157/8

1 1 1 1 1 1 1

3 1 /8 3 1 /4 3 3 /8 3 1 /2 3 5 /8 3 3 /4 3 7 /8

384.2 387.4 390.5 393.7 396.9 400.1 403.2

15

1

3

381.0

101.6 104.8 108.0 111.1 114.3 117.5 120.7 123.8

101/8 101/4 103/8 101/2 105/8 103/4 107/8

257.2 260.4 263.5 266.7 269.9 273.1 276.2

127.0 130.2 133.4 136.5 139.7 142.9 146.1 149.2

11 111/8 111/4 113/8 111/2 115/8 113/4 117/8

279.4 282.6 285.8 288.9 292.1 295.3 298.5 301.6

Alumasc Technical Helpline 01744 648400

19


Engineered Drainage Harmer LCC

7/11/02

10:46 am

Page 20

Alumasc is now firmly established as one of the leading manufacturers of premium building and construction products. A unique heritage combined with vast experience and craftsmanship derived from all corners of the industry, gives the platform to provide specifiers with one of the most diverse product portfolios available on the market. Highly regarded throughout the UK and Europe, a number of Alumasc brands are now established as world leaders in their field.

Alumasc has a firm commitment to customer service and operational excellence. This together with the company’s combined experience ensures that Alumasc understands individual needs, providing a first class service from initial design through to completion and beyond.

Architectural Rainwater Systems

Head Office Alumasc Exterior Building Products Ltd

Engineered Drainage Systems

White House Works, Bold Road, Sutton, St Helens, Merseyside WA9 4JG

Flat Roofing & Waterproofing Systems

Tel: +44 (0)1744 648400 Fax: +44 (0)1744 648401

Metal Roofing Systems Email: info@alumasc-exteriors.co.uk Façade Systems

All reasonable care has been taken in the preparation of this manual, all information, recommendations and guidance notes on the use of The Products are made without guarantee since the conditions of use are beyond the control of Alumasc Exterior Building Products Limited (The Company). The customer is responsible for ensuring that each product is fit for its intended purpose and that conditions for use are suitable. The information contained in this brochure and advice arising therefrom is free of charge and accordingly on the terms that no liability nor liability for negligence will attach to The Company or its servants in relation to any such service arising out of or in connection with this brochure. The Company pursues a policy of constant product development and information contained in this publication is therefore subject to change without notice.

1002/3.1K

www.alumasc-exteriors.co.uk


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.