Weather system Vantage Pro 2................................................................................................................. 5 LCD -1H & LCD - 3H Snow switch.................................................................................................. 6 RF-Antenna .............................................................................................................................................. 7 Multi-modem V3 ...................................................................................................................................... 8 Semi-conductive heater, LM Midi ........................................................................................................... 9 Small compact thermostat, TH-H / TH-K .............................................................................................. 10 CONTROL – Hygrostat- HY-WE .......................................................................................................... 11 Electrical socket - SD 035 Series ........................................................................................................... 12 Transformer EPNW ................................................................................................................................ 13 Power supply for DIN-rail 240/2410...................................................................................................... 14 Residential/Commercial Protection ................................................................................................... 15-16 Temperature sensor thermoelement type K and extension cable ........................................................... 17 Moisture and Temperature Sensor with Serial Interface ........................................................................ 18 Notes ....................................................................................................................................................... 19

2 | P a g e A c c e s s o r i e s


DLT – Data ‐logger and data transfer unit. Power supply 24 Vdc ‐ Fanless – Diskless ‐ DIN rail mounting

Product overview The DLT is a compact embedded PC, for Din rail mounting. Thanks to the used low power consumption CPU processor without active cooling, DLT is particularly suited for applications where reliability and performances are major requirements. The processor is scalable: this grants long life applications. Total connectivity is guaranteed by the huge amount of communication interfaces like 2 serial channels, selectable as RS-232/422/485, 10/100 Mbit/s Ethernet and 2 USB ports. The integrated video controller operates as standard VGA (CRT monitor as well as LCD panels…).

Features             

Scalable CPU, ETX technology, fanless, entry level GEODE GX1 300 MHz 24 VDC power supply SDRAM socket Compact flash socket Internal 2,5” hard disk, optional VGA Mouse and Keyboard interfaces Fast Ethernet 2 x serial channels RS232/422/485 2 x USB port PC/104 slot 0° to 55 °C operating temperature Compact aluminium housing, DIN rail mounting

Specifications Power supply • 24 VDC ±20%, 35 W, module protection by microfuse Processor • Scalable CPU, GEODETM GX1 300MHz, entry level • Fan less cooling with heatsink Memory resources • CompactFlash socket, extractable • 128/256 MB SDRAM on DIMM socket, on board ETX module • Hard Disk 2,5” (optional), on EIDE interface (max 2) Real time clock • On board • Button battery, replaceable Watchdog • Software Serial Interface • COM1, COM2 user selectable RS‐232/422/485 Parallel port • Internal interface Ethernet • 1 x 10/100Base‐T USB • 2 x USB ports Video controller • Standard VGA • 2 x EIDE interfaces EIDE PC/104 • PC/104 standard slots Connectors • COM 1, COM 2 2 x DB9 • VGA HD‐15 • USB 2 x USB • Ethernet 1 x RJ‐45 • LPT1 Standard 26‐pin, Internal, on demand • Mouse 1 x PS2 1 x PS2 • Keyboard • EIDE Primary Standard 44‐pin, step 2 (Lap‐top version) • EIDE Secondary Standard 44‐pin, step 2 (Lap‐top version) • Power supply Phoenix Contact Combicon Operating temperature • From 0°C to +55°C Storage temperature • From ‐25°C to +85°C Relative humidity • From 10% to 90% non‐condensing Mechanical construction • Compact aluminum housing for DIN‐rail mounting Dimensions • 155 x 135 x h98 mm

A c c e s s o r i e s P a g e | 3


DLT‐Screen ‐ Alternative 7” Fanless Panel PC Panel PC provides water proof/touch screen/fanless function.

With the VESA75 mounting spec and the small size panel, it is ideal for car PC application. Open-frame mechanical design is available upon customer’s request.

Technical data Dimension: .... 7” panel: 10 H x 188 W x 125 D mm .........................Case: 125 H x 188 W x 40.5 D mm Weight: ..................................... 1.2 Kgs (incl. M/B) Material:.................................................Aluminium Storage ....................................................... CF Card Part.no: ....................................................... 3950186 Optional Accessory: Wall-Mount Kit .............................Part.no 3950187

System information (please refer to M/B spec.) Main board Max. Memory CPU LCD Panel Resolution Brightness (cd/m² Contrast ratio Number of colors: Touch Screen Mounting Spec. Panel frame waterproof Expansion slot

3V700C-1R50E 3V700C-1R1OU DDR II Ram DDR II Ram 1GB 1GB VIA Eden VIA Eden ULV 500MHz 1GHz CPT CPT 800 x 480 800 x 480 250 400:1 262K 4 wires/Resistance type VESA75 IP65 Mini PCI

Dimension


Weather system Vantage Pro 2 First and only weather station in its class to use frequency hopping spread spectrum radio technology to transmit weather data wirelessly up to 1000' (300 m). Vantage Pro 2 weather stations are available in both wireless and cabled versions. All include the Davis innovative integrated sensor suite, which combines the rain collector, temperature and humidity sensors and anemometer all into one package - making setup easier than ever and improving performance and reliability.

Contents of the Free Mini Installation Kit      

1 x 1 metre (2.6ft) aluminium mast 1 x 6 inch stand-off bracket 2 x U-bolts and nuts (44mm) 4 x Exterior coach screw 4 x 10mm nylon wall plugs 2 x 6mm nylon wall plugs 10 x Cable ties 1 x Instruction manual

Delivered With Vantage Pro 2 console/receiver Integrated sensor suite and mounting hardware Integrated sensor suite includes: • Rain collector • Temperature and humidity sensors • Anemometer - 40' (12m) anemometer cable • Solar panel

Technical Data Sensor suite is solar powered Electronic components are housed in a weatherresistant shelter Console may be powered using the included ACpower adapter or with three C batteries (not included)

Customs-/Tariff code

85389099

Designed to meet the guidelines of the World Meteorological Organization, the Davis aluminium plated tipping bucket is corrosion-resistant and laser calibrated for accuracy

Anemometer The anemometer includes both wind speed and direction sensors Rugged components stand up to hurricane force winds, yet are sensitive to the lightest breeze The anemometer is wind-tunnel tested to speeds in excess of 170 miles per hour (274 km/h) Temperature and Humidity Sensors These are located within the radiation shield The shield protects the sensors from solar radiation and other sources of radiated and reflected heat

Wireless Integrated Sensor Suite The ISS runs on solar power Lithium battery provides back-up at night and on wintry, cloudy days (Solar panel is not included with cabled version) Part.no ................................................................................ 3950188

Wireless range is up to 1000' (300 m) outdoors - in line of sight Typical range through walls under most conditions is 200' to 400' (60 to 120m) Add wireless repeaters for distances up to 1.7 miles (2.7 km)

Rain Collector With it's self emptying tipping bucket is exceptionally accurate You can read rainfall amount in 0.01" or 0.2mm increments

A c c e s s o r i e s P a g e | 5


LCD ‐1H & LCD ‐ 3H Snow switch

Features & Advantages        

Description

Minimum energy costs Automatic snow melting Snow melt only when necessary Sense both temperature and precipitation Performance optimized for hydronic applications Simple installation Reliable Low cost

LCD-1H & LCD- The LCD–1H & 3H Snow Switch saves energy by providing snow melting only when required during snowfall and for a time thereafter to ensure complete melting. As heavy, wet spring and autumn snow often occurs above freezing, the LCD–1H & LCD–3H detects precipitation as snow at temperatures below 38°F (3.3°C). The LCD–1H's internal, isolated 3 amp relay contact remains closed for a 5-hour hold-on time after snowfall stops to ensure complete snow melting and pavement drying. The LCD–3H remains closed for 1-hour hold-on time. The LCD–1H & 3H Snow Switch achieves high performance at low cost through microprocessor control. Members of the LCD product family have provided more than 70 million hours of reliable snow melting control. For complete information describing application, installation and features, please contact Customer Service or check on the web at www.networketi.com. Installation The LCD–1H Snow Switch housing has one 1/2” (16mm) NPT threaded opening. Choose an unobstructed elevated location exposed to snowfall. Rigidly mount in upright, plumb position as shown. Connect the black and white wires to the 24 VAC power supply. Yellow wires are from an isolated 3 Amp resistive/1 Amp inductive relay contact. Order info Order #

Description

16793

LCD-1H snow switch (5 hour hold-on timer)

19435

LCD-3H snow switch (1 hour hold-on timer)

6 | P a g e A c c e s s o r i e s


RF‐Antenna Technical data Frequency: ..................... 800/900/1800/1900/2100 MHz Unit: ......................................................................... M/M Tolerance: ..................................................... x.xx±0…15 Surface roughness:......................................................... S .................................................................................  Part.no................................................................ 3950144 Customs/Tariff-code .......................................... 8538909

No. NAME

FINISH

QTY

01

Top cap

Black

1

02

Base

Black

1

03

Screw set

Nickel plating 1

04

RG‐174 A/U cable Black

05

SMA 180* Male

Nickel plating 1

06

Heat‐shrink tube

Black

07

Washer

Nickel plating 1

08

Nut hexagonical

Nickel plating 1

1

1

A c c e s s o r i e s P a g e | 7


Multi‐Modem V3

Technical data MultiModem Kit-V3 ......................Part.no 3950152 MultiModem Kit-V3 with temp.sensor ........ part.no 3950172 Power supply Voltage range ...................................9-28 V DC/AC Current consumption nom. ......... @ 12 VDC 25mA Current consumption max ................ @ 12 VDC 1A Air temperature when in use: ............... -20 - + 55°C Data transmission Transparent transmission ............300 – 115 200 bps GSM Tri-Band.................................. 900/1800/1900 MHz GPRS ......................................................... Class 10 Interface Serial RS232 ........................ 9-pole D-SUB Female 2 Alarm inputs ....................................... 4-28 V DC 1 Grounding output .............................. max 100mA Size L x B x H ...................................... 67 x 67 x 42 mm Weight ........................... 140g in aluminium casing Mounting....................... on DIN-rail or with screws Included accessories .......................... GSM antenna ............................................................. RS232 cable ........................................................... 230V adaptor .......................................Installation & user manual Optional accessories ...... integrated battery back-up .............................................. External relay cabling GSM/GPRS The modem handles data speeds between 300 and 115 200 Bps and has a full serial RS 232-port. The unit can be configured with standard AT commands and a user friendly PC-programme. The GSM-module is a Siemens Tri-band modem with GPRS Class 10. CPU The unit is equipped with a microprocessor which can store software for various applications. Inputs Two alarm inputs generate text messages to predefined mobile numbers when triggered. Messages can be sent both when an input goes “high” and “low” i.e. when voltage is applied and when voltage is removed from the input. Output A grounding output, activated via SMS or call, can be used to control equipment or an external relay. (A cabling with an external alternating relay is available as an option).

8 | P a g e A c c e s s o r i e s

Customs Code 85389099 Access control If activated, access list functions in the unit will monitor whether an incoming call/SMS or data call is authorised to communicate with the Multimodem V3. Up to 100 numbers can be stored in the access list. On-line affirmation The on-line affirmation feature will update the GSM-module on the network at regular intervals. This will ensure that the module is on-line with the GSM network at all times. The unit can at the same time, via dial-up and CID, confirm to a monitoring software that it is operating. The “alive” feature is free of charge. Applications The Multimodem is suitable to connect to machines with a serial communication interface and/or for monitoring of passive sensors and alarm transmission via SMS. The unit works as a regular GSM/GPRS modem, it is however adapted for industrial use and has a very high level of reliability, not attainable with a normal GSM modem. Configuration The Multimodem is easily configured with the free pc-programme Configuration Tool. Templates of settings can be saved for similar installations or as a customer log. Antenna placement is easily optimized using the programme’s signal strength indicator, ideal to ensure reliable operation. Battery back-up An integrated, charge controlled, back-up battery is availabe as an option. The unit will send SMS if external power (230V) fails and when it returns if this option is installed.


Semi‐conductive heater

LM Midi

The extremely compact, high performance switchgear cabinet h eating ”LM-Midi” is the ideal heater for the prevention of condensation in large, scolding and control governors, as well as in switch boards. ‐ ‐ ‐ ‐

With high thermal radiation by aluminium housing and the arrangement of the cooling finns Perpendicularly and horizontally applicable Thermostatic regulation by an internal thermostat High-quality cable glands made of nickel plated brass

Technical data Voltages .................................... 230 V, 24 V, 48 V AC/DC ............................................................ resistance heating ............................................. Special voltages on request Performances (P1) ..................... 125 W / 180 W / 250 W Dimensions (LxBxH) ........................... 216 x 80 x 62 mm* Mounting ........................... Clip for DIN‐rail EN 60715 or ...................................................................... screw fixing Weight .................................................................... 674 g Protection type ......................................................... IP52 Connection ............................. Cable silicone 3 x 0,75mm ...................................................... standard length 0,5m ........................................................... or plug connection Internal thermostat .............................. on: approx. 28°C .................................................... (unit self temperature) .......................................................... Hysteresis: 40K ±7K .............................................. Life span: ~ 100,000 cycles ............................. Without internal thermostat possible  Standard version

A c c e s s o r i e s P a g e | 9


Small compact thermostat

TH‐H / TH‐K

The small thermostats are particularly suitable for the use in switchgear cabinets and/or into other closed housings. Type "THK", used for the control of cooling, exhaust or as signal generators. Type "THH", finds employment as control for heaters or for switchting signal devised.

Technical data Hysteresis .......................................... 7K (± 3K tolerance) Setting range ......................................................... 0‐60°C .................................(other settings possible: ‐20…40°C) Dimensions (LxBxH) .............................. 60 x 33 x 42 mm Mounting ................................ Clip for DIN‐rail EN 60715 Weight ........................................... TH‐H: 44g; TH‐K: 46 g Protection type ......................................................... IP30 Connection .............................................. 2‐pole terminal ................................................. clamping torque: 0,4 Nm .......................................... Conductor size max: 2.5 mm² EMC ............... EN55014‐1‐2; EN61000‐3‐2; EN61000‐3‐3 Max. switching capacity ...................... AC 250 V, 10 (2) A ............................................................ AC 120 V, 15 (2) A .......................................................................... DC 30 VA Contact ................................................................ Bimetal ..................................................... TH‐H: normally closed ........................................................ TH‐K: normally open Storage temperature: ........................................ 45..80°C Certifications: ........................... UL, CSA (Controller VDE) Service life: ............................................ > 100,000 cycles

10 | P a g e A c c e s s o r i e s


CONTROL – Hygrostat‐

HY‐WE

The Hygrostat “HY/WE” is an electromechanical regulator for relative humidity. The hygrostat does not require any power supply. The switch contact can be directly used for control of electric loads.

The switch point setting (10% to 80 % rH) is done by a rotary switch. At the end position, the switch is always closed or open, independent of the air humidity value.

Tecnical data Operating voltage ........................................ 24…240V AC Setting range ............ 10 – 80% rel atmospheric humidity Dimensions: ........................................... 60 x 96 x 45 mm Mounting ............................................. DIN rail EN 60715 Weight .................................................................... 164 g Protection type ......................................................... IP30 Operation range ............................ 10…90 % rH, 20…40°C ...................................................... without condensation Switching current ..................................... humidify: 2,2A ................................................................ dehumidify: 5A Contact ............................................ Change‐over switch Connection ......................................................... 3 clamps ................................................. clamping torque: 0,4 Nm Hysteresis................ 5% nominal, response time: 15 min Sensor .................................................... Polyamide band Certifications: ......................... UL, CSA – (Controller VDE)

A c c e s s o r i e s P a g e | 11


Electrical socket

SD 035 Series

• Quickly connected • Available with or without fuse • Clip fixing

The DIN-rail mounted electrical socket can be quickly fitted and connected in enclosures allowing the use of auxiliary products such as hand l amps, measuring devices, soldering irons etc. The unit is available with and without fuse and in all major world socket standards.

Technical data Connection: ............................3x pressure lamps for ........................ stranded and rigid wire 0.5-2.5mm² Mounting: ......... clip for 35mm DIN-rail, EN50022 Casing: ........................ plastic UL94 V-0, light grey Dimensions: ................................... 92 x 62 x 48mm Weight: .............................................. approx. 0.2kg Fitting position: ........................................... variable Operating/Storage temp: ....................... -40 to 60°C Prot.type/prot.class: ....................... IP 20/I (earthed) Approvals:............... -/- (USA/canada only: UL File E222026). Customs/Tariff code: ............................... 85389099 Part.no ....................................... Se table to the right

Socket Germany France Switzerland GB/Ireland USA/Canada Italy

Operating voltage max. AC 250V AC 250V AC 250V AC 250V AC 125V AC 250V 1)

With fuse 1) Art.no/ nom.current 03500.0-00/6.3A 03501.0-00/6.3A 03502.0-00/6.3A 03503.0-00/6.3A 03504.0-00/6.3A 03505.0-00/6.3A

Fuse Ø 5 x 20mm

12 | P a g e A c c e s s o r i e s

Without fus Art.no/ nom.curren 03500.0-01/1 03501.0-01/1 03502.0-01/1 03503.0-01/1 03504.0-01/1 03505.0-01/1


Transformer EPNW

Can be used i n every part of the world thanks to its wide input-voltage range and to it having been tested and assessed by international agencies (EN/CE/UL)

Stable and short-circuit proof output with adjustable output voltage

Over-voltage protection, primary and secondary

DIN-rail mounting is as easy as could be

Compact dimensions and low weight

Wide temperaturer ange, with over-temperature protection

Very good price/performance relation

A good choice for power distribution applications in building automation and for switch-cabinet installations in automation engineering

Technical data Brief description ......... Single‐phase power unit 24 V/1A Input Input voltage range .................................... 85 – 264 V AC .................................................................. 120 ‐370 V DC Input current ............................................... 0,88 A/115 V .................................................................... 0,48 A/230 V Output Rated output voltage .................................. 24 V DC ± 1% Output voltage setting range ........ 21,6 V DC … 26,4 VDC Rated output current ......................................... 1,5 A DC General data Temperature range .................... ‐20…+60°C from 50°C derating ‐2% /K Over‐temperature protection ......................................... ‐ efficiency ............................................ 83 % at 100% load Safety ......................... UL60950‐1, EN60950‐1, EN50178 .................................... (See special technical data sheet) EMC ............................... See special technical data sheet Dimensions (W x H x D) ............... 78 x 93 (103) x 56 mm Weight .................................................................... 235 g

Construction

Dimensions

A c c e s s o r i e s P a g e | 13


Power supply for DIN‐rail 240/2410       

Only 45mm wide Input: 120/230 VAC Internal fuse Mains buffering 40ms Overtemperature protection Overvoltage protection primary and secondary Can be operated in any assembly position

Technical data Input Input voltage range Ue .................... AC 180 – 264 V, 50/60 Hz ................................ mechanical switchover to AC 90-132 V > Efficiency........................................................................ > 87% Input current limit.- ..................... < 25 Apeak type – in cold state ..................................................... < 50 Apeak type – in hot state Internal fuse ......................................................... 6.3 AT 250V Output Tolerance to V0 ........................................................ +3% /-0% Operation indicator ....................................................grön LED Ripple................................................................ < 30mV at 0°C Noise voltage ............................................................ < 120 mV Temp. coefficient ...................................................... 0.025%/K Switch on/switch off ..................... no V0 overshoot (soft-start) Start-up delay ................................................................. < 30ms Strength against......................................................... < 35 VDC Reverse-voltage Parallel connection ................................................................ no Regulation Line regulation ........................... < 0.2% for V0 at Vimin - Vimax Load regulation .......................... < 0.5% for V0 at I0 0 – 100% Response time ........................................... < 1ms at lo 20- 80% Protection and controlling Overvoltage protection................................ 105 – 125 % Uamax Load regulation .................................................... 105 – 140% i Overtemperature protection . Switches off if inside temperature becomes too high, automatic restart. Mains buffering.............................................................. > 30ms EMC Mains feed back .............. EN 61000-3-2 Class A external PFA Flicker ................................................................. EN 61000-3-3 Interference suppression/ .................... EN61000-6-2 Intensity4 Interference immunity ........... EN61000-4-2 Noice level 10V/m .......................................................... EN61000-4-3 Intensityy4 ........................................................... EN61000-4-4 Intensity 4 ........................................................... EN61000-4-5 Intensity 4 .................................................. EN61000-4-6 Noise level 10V ........................................................................... EN61000-4-11 Interference emission ........................................... EN61000-6-3 ...................................................................... EN55022 Class B .................................................Radiation depends on assembly

14 | P a g e A c c e s s o r i e s

The distance between the surrounding components and the air admission and air exit holes should be at least 20mm. Please ensure that exhaust air is not immediately sucked in again. Safety ..................... IEC 60950, EN 60950, VDE 0805 Safety Class 1 ................................................................................................... ................... UL508-listed/ UL 60950/CSA 22-2-60950, SELV .............................................................. according to EN 60950 Ensure fire protection by means of the surrounding housing system. Operting data Temperature range ......................... -25°C to 70°C, integral fan, ................................................................. air intake bottom-up Derate ......................................2.5%/K at +80°C (see diagram) Weight: ............................................................................. 0.6kg Mechanics Connection ......................... mains input: 3-pole terminal block, .................................................................... pluggable RM 7.62 .......................................... Load output: 4-pole terminal block, .................................................................... pluggable RM 5.08 Assembly: ........................... All systems can be snapped onto a ................................. symmetrical 35mm DIN-rail according to ............................ EN 50022 with a diameter of 1 to 2.5 mm or ......................................... directly be screwed onto to the wall. ...................................... Please notice the assembly conditions.


Residential/Commercial Protection

Applications  

Commercial applications requiring high sensitivity earth leakage protection from electrical shock and fire hazards. Installations exposed to high and low ambient temperatures. The hydraulic magnetic design allows the device to always keep rated current.

Features           

CE approved. UL1077 and UL1053 certified. VDE certified to DIN EN 60 947-1 and 60 9472. Small frame size (26mm wide). Energy limiting capability on both switch and circuit breaker versions. Switch version fitted with short circuit protection for additional safety. Top busbar design enables easier installation Single pole plus switched neutral earth leakage protection Trip point is unaffected by ambient temperature Current ratings up to 63A Trip indication (mid trip handle position)

Product type

QA17A

QA17C

QF17A

QF17C

Standard Ampere Ratings(A)

5 to 63 A

40 and 63 A

5 to 63 A

40 and 63 A

Sensitivity (mA)

30, 100, 300

30, 100, 300

30, 100, 300

30, 100, 300

Number of poles

1 + N

1 + N

1 + N

1 + N

Equipment type

Earth Leakage

Earth Leakage

Earth Leakage/GFCS

Earth Leakage/GFCS

Rated Voltage (V)

240

240

240

240

Rated Interrupting/

3 kA

6 kA

Withstand Capacity (kA)

3 kA

6 kA

Weight(kg)

0,26

0,24

0,26

0,24

Tripping Curves(1) (Standard)

2(1), 3

2

Operating Temperature

‐40 to +60°C

‐40 to +80°C

‐40 to +80°C

‐40 to +80°C

A c c e s s o r i e s P a g e | 15


Residential/Commercial Protection Dual

Din

16 | P a g e A c c e s s o r i e s


Temperature sensor thermoelement type K and extension cable

Range of application

Construction

Extension cable. Fabricate: Velox Delivery: ready-made lengths of 5-10-25-50-100m.

Technical data: Conductor: ..................... +Pol NiCr 1.00mm² (32x0,20mmØ) ........................................................... -Pol Ni 1,00mm² (32x0.20 mmØ)

Outer insulation: ..................... PVC, Wdd.-0,40mm Colour code: ................................... + green, - white Sheath: ..................................PUR, Wdd. – 0.80mm Colour: ........................................................... Green Outer Ø: ........................................................ 5.4mm Temperature sensor Ø 8mm

Rated voltage ..........................................max. 600V Testvoltage ................................................. 2000 V Temperature range: .............................. 5°C - +70°C Tolerance: acc. IEC 584, Sheet 3, Kl 1 ±60V(±1,5 K) Part.no: ................................................... 3950110X Customs/Tariff-code ................................ 85445980 Description: ....................... Thermoelement Type K

Heating element

Heating element

Temperature sensor placement

Temperature sensor

A c c e s s o r i e s P a g e | 17


Moisture and Temperature Sensor with Serial Interface

Performance Data • Combined temperature and humidity • • • • •

measurements Sensor in a high-grade steel enclosure with a sinter cap Resolution: 01 % rF, 0.01°C Accuracy: 2% rF, 0.3°C Windows software "Recorder“ included Calibration by means of salt reference cells

Typical Areas of Application • Supervision of storage spaces, in the foodstuff •

sector, quality assurance or in air-conditioning systems Humidity measurement systems for customer specific projects, micro-controller applications, under Windows or Linux

Windows‐Software • Display of humidity and temperature data • Calculation and display of dew-point, absolute • •

humidity, vapour pressure, saturation pressure and enthalpy Tabular presentation of measurement data Saving of data to a hard disk

This product provides a powerful system for measuring and recording temperature and relative air humidity. The compact sensor has the external dimensions Ø12 x 150 mm and is housed in an enclosure of high-grade steel. The interface converter included allows working directly from the PC or directly with customer-specific controlling and regulating systems. The front end containing the sensors is protected by a polyethylene sinter filter against water splashes and mechanical damage. The temperature sensor used is a precision NTC. Humidity is measured using a capacitative polymer sensor that will remain stable over a long time. The micro-controller on the interface converter compensates for any linearity error and temperature drift of the sensor element. The mathematical operations used guarantee excellent measuring accuracy and long-term stability, even under extreme operating conditions.

BILD The current measurement data is input as an ASCII string into the connected computer via the serial interface (RS 232 compatible). By means of the PC, the measurement data is recorded and displayed as a graphic. An easy-to-use Windows program for displaying and saving measurement data is included. Documentation describing the ASCII Protocol for data communication is provided and makes possible the integration into programs of one's own. The sensor is supplied factory calibrated. The user can check the accuracy of the sensor by means of the reference cells that are available as an accessory. Re-calibration is also possible.

Technical Specification Customs/Tariff-code ................................85389099 Humidity: measuring range .................... 0..100% rF Humidity: resolution ................................. 0.01% rF Accuracy, typically ...................... ±2% rF (at 23°C) Temperature: measuring range ................. -40..80°C Temperature: resolution ............................... 0.01°C

Description

Construction

18 | P a g e A c c e s s o r i e s

Accuracy ..................... ±0.3°K between 0 and 40°C Operating voltage DC .. 8 V DC, Protection against incorrect polarity connection Operating current .................................... ca. 30 mA Interface....... RS 232 compatible, 4800 Baud, 8 N 1 Sensor dimensions ............................150 x Ø12 mm EMV- compatibility ....... interference transmission: ......................................................... DIN EN 50081 ............... resistance to interference: DIN EN 50082 Connector ................... Data DB9 jack, pins 2 and 5 Power supply socket 3.5 mm Comes complete with humidity sensor in a highgrade steel enclosure, interface adapter with PC connection cable, Windows software, and extensive documentation. For accessories, please refer to the Summary List of Reference Numbers


Notes ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. ................................................................................................................................................................................................. .................................................................................................................................................................................................

A c c e s s o r i e s P a g e | 19


Telephone: +46-301-418 50 Email: info@vkts.se – Homepage: www.vkts.se Industrihuset, S‐438 96 HÄLLINGSJÖ, Sweden, Fax: +46‐301‐418 70 Södra Hedensbyn 43, S‐931 91 SKELLEFTEÅ, Sweden, Fax: +46‐910‐881 33

20 | P a g e A c c e s s o r i e s


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.