http://uk.latest.monier.aoe-works.de/fileadmin/bu-files/uk/Current_Web_Structure/Literature/Download

Page 1

February 2009 Uniclass L521 Cl/SfB (47)

N

GUIDE TO ROOFING SYSTEMS


CONTENTS

02

46

Know-How Introduction to Redland Training and Innovation Sustainability Dry-Fixing Advantages Effective Ventilation DesignMaster, SpecMaster FixMaster & QuantMaster EcoMaster & ViewMaster www.redland.co.uk

Profile Range 2 4 6 10 11 14 16 17

18

46 48 50 52 54 56 57 58 59 60 61

62

Slate Range Choice at a glance Natural Slate Cambrian Slate Landmark Slate Saxon Richmond Stonewold II Mini Stonewold MockBond Mini Stonewold

Choice at a glance Old Hollow Clay Pantile Cathedral Clay Pantile Landmark Double Pantile Landmark Double Roman Grovebury 50 Double Roman Regent Renown Norfolk Pantile 49 Tile

18 20 22 24 26 28 29 30 31

Metal Range

Redland Metal Roofing

62

64 Solar Range Solar Water Heating Systems

64

32

68

Plain Tile Range

Essential Roof Components

Choice at a glance Rosemary Clay Classic Rosemary Clay Craftsman Heathland Downland Plain Tile DuoPlain

32 34 36 38 40 42 44

Choice at a glance Underlays Eaves Systems Verge Systems Hip Systems Valley Systems Abutment Systems Safety Hook Ridge Systems Ventilation Tiles Ornamentals Fittings Colour Range

68 70 72 74 78 84 86 89 90 100 106 108

Product Codes Performance and Appearance Index

110 118 120


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:20

Page 2

Redland is a brand of the worldwide Monier Group. With operations in 46 countries and over 200 production sites, Monier is the leading worldwide supplier of pitched roofing materials. Operating in the UK and Ireland, our goal is to deliver high-quality roofing solutions that perfectly meet our customers’ expectations.

Redland draws on the expertise and experience gathered from more than 85 years as an industry leader. Our range of tiles, slates, renewable energy systems, fittings and accessories, combined with market-leading technical support services, enable us to deliver total pitched roofing solutions you can rely on.

“At Redland it is our aim to deliver high-quality roofs that are easy to specify, buy, install and own.”

“easy to specify” We provide services to help the specifier design and specify a pitched roof. Our roofing know-how allows us to guarantee performance and remove the specifier’s design liability.

“easy to buy” Our products are widely available, our well trained staff are easy to contact, we know our products and we understand customer needs.We aim to deliver on time and in full.

“easy to install” Our roofing know-how has enabled us to design products that are easy to install and fit together to form a roof system. Our fixing instructions are clear, and we provide customer support to help overcome difficult technical problems.

“easy to own” When correctly fixed our roofs do not fail.They last for a long time. If they should fail, we will replace the products free of charge and include any costs for labour and scaffolding. Our guarantees are relevant and credible.

For further information on Redland: Visit www.redland.co.uk or telephone our Customer Service Hotline on 08705 601000 2 KNOW-HOW

KNOW-HOW 3


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:20

Page 4

THE RIGHT STUFF When you deal with us you are dealing with people whose capability is unmatched in the industry. You can be sure that the advice you receive from our sales office, warehouse or logistics personnel is based on a passion for excellence in roofing systems. ST 4 Solar Water Heating System

Our Wind Tunnel – purpose built for testing roofing performance

INNOVATIVE THINKING At Redland we pride ourselves on our continuous development programme for new and enhanced products and services. Our roofing know-how from local and international markets, along with our extensive research and development facilities, creativity and a passion for innovation means that we can offer systems at the forefront of roofing technology. Technical Solutions Hotline

The Training and Resource Centre

Our Technical Solutions Hotline provides you with access to a wealth of roofing expertise and a comprehensive package of technical services.With their in-depth knowledge of our products and the wider aspects of roofing, the Redland Technical Solutions team is uniquely qualified to assist you with your project.

Underpinning our roofing expertise is our purpose-built Training and Resource Centre, where Redland personnel, customers and specifiers regularly undertake in-depth classroom and practical ‘hands on’ training. Since the Training and Resource Centre was established, thousands of people have received training within our state-of-theart workshops and conference rooms.

Continuing Professional Development We are a member of the RIBA CPD providers network and offer a range of CPD seminars designed to help specifiers identify potential roofing problems and provide practical solutions.

In addition to products that enhance the roof ’s function, we have also developed products such as Rapid Vented Ridge and Rapid Hip that are quick and easy to install, reducing the completion time on site.These systems provide a visually appealing, weathertight roof.

Besides roofing systems, we continue to develop our market-leading technical services. Our website has been further enhanced. It now contains over 5,000 downloadable CAD drawings and includes the innovative ViewMaster service: online software that allows you to select different tiles and colours in order to visualise the appearance of the roof.

Rapid Vented Ridge – Universal System

We also provide training to achieve professional Licentiate or Associate membership of the Institute of Roofing. Each ‘fastrack’ course takes just 10 days (over a 10 week period).

For further information on Technical Solutions: See pages 14-16 Technical Solutions Hotline 08708 702595 Email technical.redland@monier.com Redland is recognised as an Investor in People, meeting a wide range of criteria on managing staff training, development and communication issues

4 KNOW-HOW

Thanks to Redland’s long-standing experience and expertise in the area of training, it holds a position on the National Roof Training Committee, which was formed from the Roofing Industry Alliance (RIA) initiative, in order to help improve skill levels and professionalism within the industry.

For further information on our training courses: visit www.redland.co.uk/training e-mail training.redland@monier.com telephone our Training and Resource Centre on 01285 863545 For CPD modules at your premises: telephone our Customer Service Hotline on 08705 601000

KNOW-HOW 5


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:21

Page 6

SUSTAINABILITY OUR GOALS AND VALUES

REDUCING OUR FOOTPRINT

Sustainable construction requires consideration of not only the environmental impacts of construction but also the social and economic impacts as well. Reducing the built environment’s impact on carbon dioxide and other emissions to help tackle climate change and pollution, the efficient use of scarce resources, and improving health and safety represent just some of the challenges facing the construction industry. As a responsible manufacturer, Redland is committed to helping meet these challenges. Drawing upon its heritage, Redland is a name that can be trusted to help meet the contemporary challenges of sustainable construction. Since its foundation in 1919 Redland has dedicated itself to meeting the challenges faced by the construction industry. In 1926 Redland played an integral part in the construction of post-war Britain, supplying concrete roof tiles that were desperately needed in the absence of coal-fired clay tiles that were unavailable due to the general strike. A generation later Redland was instrumental in re-roofing London, with its mass-

produced Redland 49 concrete tile, establishing itself as a staple of the London landscape. With its Queen’s Award-Winning Cambrian Slate launched in the mid1980s – a product ahead of its time in terms of its high recycled waste content – Redland demonstrated that a traditional slate roof appearance could be achieved with a more cost-effective single lapped tile. In 1997 – before the Kyoto international agreement on reducing carbon dioxide emissions was signed – Redland was the first roof tile

manufacturer to launch a roofintegrated photovoltaic solar panel for generating electricity from a renewable source. Redland’s goal is to be the preferred supplier for its customers in terms of meeting their sustainable roofing needs while reducing our environmental and other impacts. To achieve this goal Redland invests significantly every year in our core values of roofing know-how, industrial excellence and customer focus.

Cambrian Slate

As well as working with the Environment Agency to help protect and improve the environment, Redland operates an environmental policy and management system across all its sites in the UK and Ireland, covering energy efficiency, waste minimisation, water efficiency and pollution reduction. Our continuous improvement process ensures that the embodied environmental impacts of Redland products are minimised.

• Raw materials – Our concrete, clay and Cambrian products are manufactured from raw materials that are over 80% (by volume) sourced from suppliers operating to the ISO 14001 environmental management standard. Redland is working with its supply chain to increase these percentages. • Energy efficiency – Every year we benchmark all our UK plants against over 200 Monier Group roofing plants around the world, to help improve energy efficiencies and learn from sharing best practice. Our UK plants currently rank among the best in the world as we constantly strive to further minimise our impact on the environment. • Recycling waste material at our plants – The recycling of broken concrete and clay tiles and waste mortar for use in our tile production continues to increase, thus minimising the amount of waste solids having to be removed from site. Polymer coatings are recycled at all concrete plants where used. Cambrian Slate itself includes a minimum of 60% recycled Welsh slate taken from slate waste piles.

Furthermore, our Cambrian plant has reduced its reject rate, with only 1% of total raw materials going to landfill. • Waste water recycling and treatment – Surplus water used during production is recycled and used in the manufacturing of other products. We have also installed water treatment plants and/or settlement lagoons at plants to ensure that any water runoff is correctly treated before it enters into the water courses. • Packaging – We annually review our packaging and the energy used to wrap our products. Supplier packaging is recycled wherever possible.We have also introduced a pallet returns system where our customers are encouraged to return the wooden pallets on which our products were packaged. These pallets are then reused for future product packaging. We currently reuse 100,000 pallets per year.

• Logistics – Our 8 plants and 4 depots are strategically positioned throughout the UK to reduce the amount of transportation of products around the country, thereby reducing congestion and pollution. Our haulier sees the use of biofuel as a major step forward in reducing their carbon footprint and currently have 750 of their 8000 vehicles running on a 50:50 standard diesel to biofuels mix. • Recycling used product at the end of its life – All our concrete tiles can be recycled for use as aggregate in building applications such as roads and paths, and all our plastic components are also fully recyclable. Clay tiles can be reused.

Making Redland tiles in the 1920's

“meeting the needs of the present without compromising the ability of future generations to meet their own needs” 6 KNOW-HOW

KNOW-HOW 7


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:22

Page 8

SUSTAINABILITY ROOFING MATERIALS Fossil fuel energy use, and the carbon dioxide emissions produced as a result, is thought to be the single largest threat to our planet. In the UK about 50% of all energy use results from the construction and operation of buildings. Although the embodied energy of building products is less significant than the energy used to operate buildings, the focus on reducing the impact of building products is likely to increase. The manufacture of building products generates various environmental impacts in terms of energy, waste, water use and pollution. Although the sustainability of building products is difficult to quantify, the Building Research Establishment Environmental Assessment Method (BREEAM) has become the standard tool in the UK for quantifying the overall embodied environmental impact of building materials, the building elements (roofs, walls, floors, windows, etc) they make up, and buildings as a whole. The BRE produce a guide using BREEAM called the Green Guide to Specification, which summarises the full life cycle impact of building elements (roofs, walls, floors, etc), depending on the materials used as part of standard construction details.The current Green Guide grades these elements on an A+, A, B, C, D, E scale where A+ represents the lowest environmental impact and E the highest.

• Redland Concrete and Clay Tiles As members of the Concrete Tile Manufacturers Association and Clay Roof Tile Council, data supplied for Redland concrete and clay roof tiles enabled the 2008 BRE Green Guide to Specification to award the highest A+ rating (lowest environmental impact) for generic concrete interlocking and plain tiles in all roof constructions. Clay tiles achieve either an A+ or A rating depending on roof construction. • Redland Cambrian Slates are the most eco-friendly resin slates available.The 2008 Green Guide to Specification awards generic resin slates an A rating when part of standard roof constructions.

8

8 KNOW-HOW

• Redland Natural Slate – Redland supplies only the highest quality natural slates from Spain and Argentina through a partnership agreement with slate specialists SSQ Group. Generic natural slate from the UK achieves an A rating in the 2008 BRE Green Guide to Specification for standard roof constructions. • Redland Metal Roofing – Redland’s metal roofing range of coated steel profiled sheet products is manufactured within strict environmental targets. The 2008 Green Guide to Specification awards generic coated steel profiled sheet products an A rating for common constructions such as double skin construction. Steel can also be recycled an unlimited number of times without losing its quality.

RENEWABLE ENERGY For a typical building only 10% of the energy it has consumed over its lifetime is a result of its construction. Approximately 90% of energy consumption results from the provision of heat and power.To reduce energy consumption and carbon dioxide emissions therefore requires buildings that are energy efficient in use. However, to operate a building without producing carbon dioxide emissions requires renewable, zero carbon sources of energy to provide both heat and power. Harnessing solar energy is one of the most attractive means of generating zero carbon, renewable energy for use in buildings, and the roof is the ideal surface for solar energy collection.

ST 4 Solar Water Heating System

The solar water heating roof panel system from Redland has been specifically designed by the Redland roofing experts for integration into pitched roofs.The solar water heating system generates domestic hot water and when connected to the household hot water system, can significantly reduce consumption of natural gas or other fossil fuels.The system is supplied with a standard hydraulic control kit containing controls, valves, pump, sensors and expansion vessel, as well as a fixing system that allows seamless, guaranteed secure and weathertight integration into the roof surface. The Redland solar water heating system can also be used for space heating or swimming pools.

KNOW-HOW 9


ONCE DRY-FIXED,THEY STAY FIXED

EFFECTIVE VENTILATION

Redland leads the way in the development of mechanical or ‘dry-fix’ roofing systems to provide neat, maintenance-free and cost effective roofing solutions that will stay put no matter what the weather brings.

Good roof design does not just mean choosing the right tile or slate. The protection of the supporting structure from the harmful effects of condensation is equally important.The proven method for preventing condensation is through the use of effective roof ventilation.

Our dry-fix systems eliminate the need for mortar bedding ridge, hips and verges, and have a number of advantages: • Fully tested against the elements to secure the roof in severe weather conditions • Eliminate problems of mortar failure due to poor workmanship • Maintenance-free • Quick and easy to fix with no special tools required • Can be laid even when bad weather is expected • Incorporate ventilation at the ridge • Compatible with most tiles and slates • Comply with BS 5534 requirements for mechanical fixing, and BS 5250 for ventilation Like all of our products, the durability of our dry-fix systems has been extensively tested under all climatic conditions, from the UV rays of the blazing sun to sub-zero temperatures. They are also laid on roofs in our purpose built wind tunnel to assess their performance against the UK and Ireland’s most severe storm conditions.This thorough approach has enabled us to achieve Agrément Certification for the majority of our dry fixed systems. Based upon our industry leading know-how we are able to guarantee that a complete Redland roof covering will remain secure and weathertight for 15 years.

Storm damage can be prevented by using our dry-fix systems.

Condensation in roof spaces has become an increasing problem for several reasons. Part L of the building regulations is driving up standards for the airtightness of dwellings at the same time as encouraging use of increased levels of insulation. These changes in building standards – to reduce energy consumption – coupled with householders’ increasing use of appliances such as dishwashers and tumble dryers, have contributed to the increasing presence of water vapour in colder roof spaces. BS 5250, Code of practice for control of condensation in buildings, sets out best practice recommendations for managing condensation risk in roofs and complying with Part C of the building regulations. Specification of the most appropriate form of roof ventilation depends largely on how airtight the ceiling is. Broadly speaking, ventilation solutions can be divided into those designed for roof constructions with a well-sealed ceiling (Breathing Roof Solutions) and those where the ceiling airtightness is not as good (Traditional Ventilation Solutions). Well-sealed ceilings With traditional construction methods it is not possible to guarantee a completely sealed ceiling. It is also not possible to guarantee that the ceiling will remain sealed for the design life of the building.

With care over design and good workmanship, however, it is possible to achieve a well-sealed ceiling such that less ventilation is needed than provided by traditional ventilation solutions. BS 9250:2007, Code of practice for design of the airtightness of ceilings in pitched roofs, describes both the detailed requirements and robust details for achieving a well-sealed ceiling. Requirements include the presence of well-sealed pipe and cable penetrations including light fittings, in addition to a well-sealed loft hatch. Redland’s range of Breathing Roof solutions provide the optimum specification when a well-sealed ceiling is installed.

For further information on dry-fix systems refer to the following pages: Verge Hip

10 KNOW-HOW

74 - 77 78 - 83

Abutment 86 - 87 Ridge 90 - 99

KNOW-HOW 11


RED1094_GTRS_GB_Intro.qxd

3/2/09

16:18

Page 12

Breathing Roof Solutions The diagrams below show a summary of the products we provide to satisfy the requirements of BS 5250 5mm

Insulation at Ceiling Joist Level – Well Sealed Ceiling • Standard duo-pitch roof with Spirtech 250 underlay • Underlay Support Tray at eaves

5mm

REDLAND BREATHING ROOF SOLUTIONS Redland’s range of Breathing Roof solutions provides specifiers with simple, robust and guaranteed BS 5250-compliant specifications, designed to meet changes in building standards. When used in conjunction with a well-sealed ceiling Redland Breathing Roof solutions combine all the benefits of a vapour permeable underlay with the reliability and security of a dry-fix ventilated ridge system to control condensation risk, even under severe conditions such as when newly built dwellings are drying out. Redland Breathing Roof solutions use Spirtech 250 vapour permeable underlay laid short at the ridge, in combination with Dry or Rapid Vented Ridge to provide a secure, weathertight system against both storm damage and roof condensation. A fundamental requirement of Breathing Roof solutions is the achievement of a well-sealed ceiling. Failure to achieve this level of ceiling airtightness significantly increases the risk of roof condensation.

Performance Redland is able to provide a complete 15 Year Roof System Guarantee for its Breathing Roof solutions and, when part of a SpecMaster project (see page 15), a full 15 Year SpecMaster Guarantee covering design liability as well. Benefits • Suitable for most roof designs • Guaranteed weathertightness • Dry-fix technology ensures guaranteed, securely fixed ridge tiles • Improved energy-efficiency resulting from reduced heat loss through the roof • Single point of manufacturer responsibility, from the underlay to the tile • No eaves ventilation product required, simplifying eaves details • High-level ventilation ensures water vapour loads are managed effectively

Top Edge Abutment Ventilation Unit (see page 87)

Rapid Vented Ridge (see page 92) DryVent Ridge (see page 90)

5mm

Insulation at Ceiling Joist Level – Well Sealed Ceiling • Lean-to or mono-pitch roof with Spirtech 250 underlay • Underlay Support Tray at eaves

Rapid Ridge (see page 92) Dry Ridge (see page 90)

Rapid Vented Ridge (see page 92) DryVent Ridge (see page 90)

Insulation at Rafter Level – Well Sealed Ceiling • Duo-pitch roof with a 50mm air gap between insulation and Spirtech 250 underlay • Underlay Support Tray at eaves

Insulation at Rafter Level – Well Sealed Ceiling with Vapour Control Layer • Duo-pitch roof with a 50mm air gap between insulation and Spirtech 250 underlay • Underlay Support Tray at eaves

Traditional Ventilation Solutions The diagrams below show a summary of the products we provide to satisfy the requirements of BS 5250 5mm

Rapid Vented Ridge (see page 92) DryVent Ridge (see page 90)

Top Edge Abutment Ventilation Unit (see page 87)

RedVent Eaves (see page 73)

10mm

10mm

Insulation at Ceiling Joist Level – • Standard duo-pitch roof with Veltitech underlay • Where rafter pitch is 15º or less the low-level ventilation gaps must be increased from 10mm to 25mm. High-level ventilation is required on rafter pitches above 35˚ and/or at spans more than 10m

Rapid Vented Ridge (see page 92) DryVent Ridge (see page 90)

5mm

ThruVent or RedLine Ventilation Tile (see page 100-105)

5mm

RedVent Eaves (see page 73)

10mm

Insulation at Ceiling Joist Level – • Lean-to or mono-pitch roof with Veltitech underlay • Where rafter pitch is 15º or less the low-level ventilation gaps must be increased from 10mm to 25mm

Rapid Vented Ridge (see page 92) DryVent Ridge (see page 90)

5mm

5mm RedVent 25 (see page 73)

RedVent Eaves (see page 73)

10mm

Breathing Roof systems are covered by the comprehensive Redland 15 Year Roof System Guarantee when used with Redland tiles, slates, fittings and accessories.

12 KNOW-HOW

10mm

Insulation at Ceiling Joist Level – • Duo-pitch roof with dividing walls with Veltitech underlay • Where rafter pitch is 15º or less the low-level ventilation gaps must be increased from 10mm to 25mm.

25mm

25mm

Insulation at Rafter Level – • Duo-pitch roof with a ventilated 50mm air gap between insulation and Veltitech underlay • Underlay Support Tray at eaves

KNOW-HOW 13


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:24

Page 14

TIME SAVING, FLEXIBILITY, PEACE OF MIND Redland has developed a comprehensive range of FREE technical services that will save you time and give you peace of mind that your project is in safe hands.

DesignMaster

QuantMaster

A comprehensive CAD library of over 5,000 quality roofing drawings

A roof materials quantity estimating service

• • • •

• Quantifies all roof materials including tiling battens and leadwork • Eliminates potential costs of over-ordering or downtime resulting from under–ordering • To obtain a QuantMaster send your drawings to Redland Technical Solutions

Saves time preparing working drawings Prevents risk of incorrect application Drawings available in both DWG and DXF formats Each drawing includes a complementary NBS-based specification clause • Available for download at www.redland.co.uk/designmaster or DesignMaster CD-ROM available

FixMaster

SpecMaster

Redland’s fixing specification service tailored to customers’ needs

A complete guaranteed roof specification service

• Removes the potential for roof failure

• Relieves the burden of the specification writing process

• Offers the choice of either a fixing specification tailored to a specific roof design and location or a generic fixing specification

• Tailored specification clauses in NBS-based format

• Full assessment of the impact of all nearby man-made and natural topographical features and complies with all British standards • To obtain a tailored fixing specification: Complete an online data sheet at www.redland.co.uk/fixmaster or contact the Technical Solutions Hotline • To obtain a generic fixing specification: Download zonal fixing specifications for all our tiles from www.redland.co.uk/literature

• Fully compliant with all relevant British Standards • 15 year design liability guaranteed for all roofs designed and built in accordance with SpecMaster • New build and re-roofing projects • Provides peace of mind for you and your clients • To obtain a SpecMaster: complete an online data sheet at www.redland.co.uk/specmaster or contact the Technical Solutions Hotline

Workmanship Warranty

NEW

Independently insured cover for the workmanship element of your SpecMaster project is now available via Redland's partnership with Auditing Workmanship & Materials Ltd. Contact Redland Technical Solutions for more information.

For further information on Technical Solutions: Technical Solutions Hotline 08708 702595 Email: technical.redland@monier.com Redland Technical Solutions, Monier Ltd, Broadway Lane, South Cerney, Cirencester, Gloucestershire GL7 5UH

14 KNOW-HOW

KNOW-HOW 15


RED1094_GTRS_GB_Intro.qxd

3/2/09

14:24

Page 16

www.redland.co.uk

SUSTAINABLE TECHNOLOGY GETTING YOU CONFUSED?

Our website is the most information-rich roofing site online, and provides invaluable help in the selection and specification of our roofing materials.Whether it’s help with product selection, the ability to download CAD drawings or just a comprehensive source of information you require, this site will soon become a firm favourite.

EcoMaster A complete guaranteed specification service for projects involving Redland renewable energy systems • Relieves the burden of the specification process for Redland solar water heating systems

• 15 year roof system guarantee for all roofs designed and built in accordance with EcoMaster

• Calculation of estimated energy benefit of Redland solar water heating installation

• Specific product guarantees for renewable energy systems

• Fully compliant with all relevant British Standards, Good Practice Guides and Building Regulations

• To obtain an EcoMaster: complete an on-line datasheet at www.redland.co.uk/ecomaster or contact the Technical Solutions Hotline

• Access to an approved installer network

• Provides peace of mind for you and your clients

STRUGGLING TO VISUALISE YOUR NEW ROOF?

• The ability to download CAD drawings, literature and BBA certificates • ViewMaster allows you to see how different tiles and colours alter the appearance of the roof • Product finder, a searchable database for products by colour and finish • Photo gallery, an easy-to-navigate database of all our tiles and slates in use on actual projects

• Technical sections on tiles, slates, fittings and accessories as well as FAQs • Online forms to request fixing and roofing specifications • Colour swatches and photographs of all our tile profiles

• Online request facility for literature and tile samples • Section on CPD and training courses available • News section with the latest information on our products and services

ViewMaster The online software that enables you to ‘try before you buy’

1

Go to ViewMaster and choose the house type that best resembles yours.

2

Choose a tile type and tile colour.

ViewMaster is a quick and easy way to see how different Redland product combinations look when laid on a roof.

3

Then click on ridge type and make your selection.

To access ViewMaster visit: www.redland.co.uk/viewmaster

4

Finally you have the option to select a solar water heating system.

Images tailored to your specific roof and property can also be obtained from selected merchants and contractors. For further information contact Technical Solutions.

1

16 KNOW-HOW

2

You can click ‘reset all criteria’ at any point and start again to view different product combinations.

3

4

KNOW-HOW 17


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 18

SLATE RANGE

The Redland range now includes two high quality, single source natural slates.The Redland Del Carmen and Redland Riverstone slates are sourced exclusively from select quarries in Spain and Argentina and are characterised by high performance properties and appealing aesthetics. Our flagship Cambrian Slate is made using over 60% recycled Welsh slate. It is light in weight and gives the visual appearance and surface variation of quarried slate. Landmark Slate is an attractive, cost-effective alternative to natural slate, with a special surface finish that gives a long-lasting colour. The authentic look of Saxon and Richmond Slates is enhanced by a thin leading edge, whilst Mini Stonewold offers an extremely cost-effective slating solution.

The slate range delivers the simple beauty of a slated roof, underwritten by the comprehensive Redland 15 Year Roof System Guarantee for total peace of mind.

HOW ARE YOU VENTILATING YOUR ROOF? Eaves Ventilation Systems 72 - 73 Ridge Ventilation Systems 90 - 95, 98 Top Edge Abutment Ventilation System 87 Ventilation Tiles 100, 104

RedVent Eaves Ventilation System see page 72

RedLine Ventilation Tile see page 100

HOW ARE YOU PREVENTING STORM DAMAGE? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

76 78 - 83 86 - 88 90 - 99 110 - 117

Natural Slate

Cambrian Slate

Landmark Slate

Saxon

Richmond

Stonewold II

Mini Stonewold

MockBond Mini Stonewold

Page No.

20

22

24

26

28

29

30

31

Min. Pitch

From 25º

15º

22.5º

25º

22.5º

17.5º

17.5º

17.5º

Weight*

35.7 – 55.4 kg/m2

17kg/m2

52kg/m2

50kg/m2

49kg/m2

50kg/m2

49kg/m2

49kg/m2

Cover

18.8 – 30.8 slates/m2

13.3 slates/m2

11.1 slates/m2

11.1 slates/m2

11.1 slates/m2

8.2 slates/m2

9.9 slates/m2

9.9 slates/m2

Premium quality single source natural slates

Authentic slate look with minimum 60% recycled slate content

Rich, long lasting colours on a thin leading edge slate

Thin leading edge slate with a distinctive riven surface

Thin leading edge slate

Large format interlocking slate

Standard format interlocking slate

Small format look from a standard interlocking slate

Appearance

DryVent Ridge System see page 90

Rapid Hip System see page 80

Weight and cover based on maximum gauge. Minimum pitches are based on maximum rafter lengths of 10m. For rafter lengths greater than this please contact our Technical Solutions Hotline on 08708 702595. All slates must be laid broken bonded, normally from right to left. * All weights nominal.

18 SLATE RANGE

SLATE RANGE 19


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 20

NATURAL SLATE How are you ventilating your roof? The premium quality Redland Del Carmen Ultra and Redland Riverstone Ultra slates are sourced exclusively from select quarries in Spain and Argentina. Both are characterised by high performance properties and appealing aesthetics. Both come with the added benefit of the Redland 15 Year Roof System Guarantee.

Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 112

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Fixing Nails

110 78 - 81 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data DEL CARMEN Grade Ultra Thickness Standard 5-6mm Size 500 x 250mm Minimum Pitch (moderate exposure)# 25˚ Holing Gauge (from head of slate) 195 Cover Covering capacity at 80mm headlap* 18.8 slates/m2 Weight (approx.) single slate 1.9kg per m2 at 80mm headlap* 35.7kg Number of Slates/Pallet (average) 740 RIVERSTONE Grade Thickness Size Minimum Pitch (moderate exposure)# Holing Gauge (from head of slate) Cover Covering capacity at 80mm headlap* Weight (approx.) single slate per m2 at 80mm headlap* Number of Slates/Pallet (average)

Riverstone Apartments, Budleigh Salterton, Devon Del Carmen – Apartments and retail development,Thames Edge, Staines

Riverstone was selected for its distinctive grey/green colour and a dressed edge finish. Riverstone is mined from the long-established San Luis quarry in Argentina’s La Florida region using the latest extraction techniques.

30.8 slates/m2 1.8kg 55.4kg 780

Ultra Standard 4-7mm 400 x 250mm 30˚ 152mm 24.7 slates/m2 1.5kg 37.1kg 680

# For high exposure pitch requirements please contact Technical Solutions. * Headlap will vary dependent on pitch and slate size at the standard holing gauge. Please contact Technical Solutions.

Redland Del Carmen and Redland Riverstone are sold by Redland through a partnership agreement with slate specialists SSQ Group.

Del Carmen

20 SLATE RANGE

Ultra Heavy 7-9mm 400 x 200mm 30˚ 152

Riverstone

Product Codes

110 - 112 SLATE RANGE 21


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 22

CAMBRIAN SLATES How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

Cambrian Slates embody the beauty and character of natural slate. Made in Wales from over 60% recycled Welsh Slate, Cambrian tops the range in both looks and performance and has a proven track

70 - 71 72 - 73 90 - 95, 98 87 104

How are you preventing storm damage?

record even on pitches as low as 15°. Whilst light

Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

in weight, Cambrian’s unique three-point fixing makes it suitable for even the most exposed sites.

76 78 - 83 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 15° 25°

300 x 336mm at 75mm headlap at 50mm headlap

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch (subject to fire resistance requirements above 69˚) 90° Maximum Headlap 90mm Minimum Gauge/Batten Spacing 210mm Maximum Gauge/Batten Spacing below 25° 225mm 25° and over 250mm Hanging Length (approx.) 294mm Cover Linear cover of 1 slate 300mm Covering capacity at maximum gauge 13.3 slates/m2 (all figures are net and do not allow for wastage)

Because of its high slate content, Cambrian weathers like natural slate

Cambrian, Slate Grey Library, Bournemouth University

22 SLATE RANGE

Saunders Architects selected Cambrian Slates for the new library at Bournemouth University because it is a high building located on an exposed site close to the sea. Cambrian’s high natural slate content ensures even weathering which will help to blend the roof into the environment. The three point fixing guarantees minimal maintenance.

Through coloured

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Pack Packs/Pallet

1.24 tonnes 17kg/m2 0.76 tonnes 4.0m/m2 38 x 25mm 50 x 25mm 30 x 2.65mm# 600 10 60

* All weights nominal #

Heather 28

Langdale Green 29

Slate Grey 30

Annular ring-shanked nail

Product Codes

110 - 112 SLATE RANGE 23


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 24

LANDMARK SLATE How are you ventilating your roof? Landmark Slate is an attractive, cost-effective alternative to natural slate. For a fraction more than the price of a standard concrete slate, Landmark will give you a good-looking roof with looks that will last over three times as long. Landmark Slate’s special surface finish gives you a roof with an authentic slate aesthetic which will weather in sympathy with the building but won’t break the bank.

Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

76 78 - 81 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch

412 x 334mm 22.5º

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

The Ambi-Dry Verge System (see page 76) provides a neat, maintenance - free finish to the verge

Landmark Slate, Brecon Grey Private houses, St Mary’s Island, Chatham, Kent

The classic look and long-lasting colour of Landmark Slates adds to the vernacular style of these modern homes at a Countryside Properties’ development in Chatham, designed to reflect the spirit of a traditional Kent fishing village.

Through coloured

Terracotta Brindle 43

24 SLATE RANGE

Brecon Grey 47

ColourFusionTM

Snowdon Grey 49

Maximum Pitch (subject to fixing specification) Minimum Headlap Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Hanging Length (approx.) Cover (all figures are net and do not allow for wastage) Linear cover of 1 slate Covering capacity at max. gauge Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Pack Packs/Pallet

90° 112mm 159mm 253mm 300mm 392mm 301mm 11.1 slates/m2 4.70 tonnes 52kg/m2 1.00 tonne 3.33m/m2 38 x 25mm 50 x 25mm 50 x 3mm 210 35 6

* All weights nominal

Product Codes

110 - 112 SLATE RANGE 25


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 26

SAXON How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

Designed with a riven surface and chamfered edge to give the appearance of authentic quarried slate, Saxon matches this visual appeal with the convenience and performance of a machine-made,

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage?

interlocking slate.With a minimum pitch of 25º,

Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

Saxon offers even more design flexibility to produce roofscapes of quality and distinction.

76 78 - 81 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch

412 x 334mm 25°

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Saxon with its riven surface and chamfered edge gives the appearance of quarried slate

Saxon, Slate Blue Apartments, Poole, Dorset

26 SLATE RANGE

Saxon’s riven slate appearance adds character to the intricate roofscape of this prestigious housing development on the Dorset coast. Dry Hip, Dry Verge and Dry Ridge Systems were used to ensure the long-term durability of the vulnerable roof perimeters at this exposed site.

Through coloured

Slate Blue 57

Highland Black 63

Painted

Welsh Blue 64

Maximum Pitch (subject to fixing specification) Minimum Headlap Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Hanging Length (approx.) Cover (all figures are net and do not allow for wastage) Linear cover of 1 slate Covering capacity at max. gauge Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Packs Packs/Pallet

90° 112mm 159mm 253mm 300mm 386mm 300mm 11.1 slates/m2 4.68 tonnes 50kg/m2 1.14 tonnes 3.33m/m2 38 x 25mm 50 x 25mm 50 x 3mm 240 40 6

* All weights nominal

Product Codes

110 - 112 SLATE RANGE 27


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 28

RICHMOND

STONEWOLD II How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

76 78 - 81 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch

412 x 334mm 22.5º

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch (subject to fixing specification) Minimum Headlap Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Hanging Length (approx.) Cover Linear cover of 1 slate Covering capacity at max. gauge

Richmond provides a cost effective roofing solution where an authentic slate appearance is called for. Its unique design offers a thin leading edge and hidden interlock without compromising strength, durability and weathertightness.

The original interlocking concrete roofing slate, that makes the roof easy to build even at pitches as low as 17.5°. It provides a cost-effective slated roof effect.

Size (overall) Minimum Pitch

300mm 11.1 slates/m2

430 x 380mm 17.5º

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch Minimum Headlap Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Hanging Length (approx.) Cover Linear cover of 1 slate Covering capacity at max. gauge

90° 112mm 159mm 253mm 300mm 390mm

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Pack Packs/Pallet

Technical Data

44° 75mm 125mm 305mm 355mm 379mm 343mm 8.2 slates/m2

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm after centres up to 600mm Number of Slates/Pallet Slates/Pack Packs/Pallet

4.58 tonnes 49kg/m2 1.11 tonnes 3.33m/m2 38 x 25mm 50 x 25mm 50 x 3mm 240 40 6

Through coloured

Through coloured

6.34 tonnes 50kg/m2 1.23 tonnes 2.82m/m2 38 x 25mm 50 x 25mm 192 32 6

* All weights nominal

* All weights nominal

Product Codes 28 SLATE RANGE

110 - 112

Slate Grey 30

Farmhouse Red 39

Breckland Brown 52

Slate Grey 30

Terracotta 34

Tudor Brown 36

Product Codes

110 - 112 SLATE RANGE 29


RED1094_GTRS_GB_Range.qxd

30/1/09

17:37

Page 30

MOCKBOND MINI STONEWOLD

MINI STONEWOLD

How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

76 78 - 81 86 - 88 90 - 99 112

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 17.5° 22.5°

418 x 334mm at 100mm headlap at 75mm headlap

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 22.5° 22.5° and over Hanging Length (approx.) Cover Linear cover of 1 slate Covering capacity at maximum gauge

90° 125mm 293mm

Through coloured

Based on the Mini Stonewold slate the MockBond variant has a dummy bond line down its centre. This creates the impression of two small units suggesting the appearance of a small format slate when laid.

Through coloured

Painted

NEW

NEW 318mm 343mm 397mm 294mm 9.9 slates/m2

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Pack Packs/Pallet

A flat concrete slate which can be laid at pitches as low as 17.5°, for new build or re-roofing applications. Our most economical concrete slate with interlocking edges for simple construction.

Anthracite 13

Slate Grey 30

Terracotta 34

Anthracite 13

30 SLATE RANGE

Terracotta 34

5.10 tonnes 49kg/m2 1.12 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 50 x 3.35mm 216 36 6

Tudor Brown 36

Farmhouse Red 39

Breckland Brown 52

Tudor Brown 36

NEW

* All weights nominal

Product Codes

Slate Grey 30

Farmhouse Red 39

Breckland Brown 52

Technical Data Size (overall) Minimum Pitch and Headlap 17.5° 22.5°

418 x 334mm at 100mm headlap at 75mm headlap

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 22.5° 22.5° and over Hanging Length (approx.) Cover Linear cover of 1 slate Covering capacity at maximum gauge

90° 125mm 293mm 318mm 343mm 397mm 294mm 9.9 slates/m2

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Slates Number of Slates/Pallet Slates/Pack Packs/Pallet

5.10 tonnes 49kg/m2 1.12 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 50 x 3.35mm 216 36 6

* All weights nominal

110 - 112

Breckland Black 53

Black 63

Breckland Black 53

Product Codes

110 - 112 SLATE RANGE 31


PLAIN TILE RANGE

The Rosemary name is synonymous with clay plain tiles, adding distinction and character to pitched roofs for over 160 years. For a cost-effective solution with a traditional aesthetic appeal, Heathland and Downland concrete plain tiles combine the character and appearance of hand-made clay plain tiles with the performance of a machine-made tile.The classic concrete Plain Tile is a cross-cambered tile, offered in a wide variety of natural colours.

The range is complemented by the DuoPlain tile, which combines the classic proportions of traditional plain tiles with all the benefits of a large-format, interlocking tile.

Adaptability is the key feature of the plain tile range, with a wide range of clay and concrete tiles suited to almost any pitched roof design.

HOW ARE YOU VENTILATING YOUR ROOF? Eaves Ventilation Systems 72 - 73 Ridge Ventilation Systems 90 - 95, 98 Top Edge Abutment Ventilation System 87 Ventilation Tiles 102 - 105

RedVent Eaves Ventilation System see page 72

RedLine Plain Tile Ventilation Unit see page 102

Rosemary Clay Classic

Heathland

Downland

Plain Tile

DuoPlain

Page No.

34

36

38

40

42

44

Min. Pitch

35º

35º

35º

35º

35º

25º

67kg/m2

78kg/m2

77kg/m2

77kg/m2

77kg/m2

55kg/m2

60 tiles/m2

60 tiles/m2

60 tiles/m2

60 tiles/m2

60 tiles/m2

17.7 tiles/m2

Handcrafted appearance clay tiles in warm, rustic colours and natural textures

Finest machine-made clay tiles in single or double camber

Handmade clay look with uneven edges and a sanded finish

Random textured surface and deckled leading edge

Traditional cross cambered plain tile

Plain tile appearance from an interlocking large format tile

Weight*

ADDING CHARACTER TO YOUR ROOF Adding character to your roof Ornamental Tiles, Ridges and Finials

Rosemary Clay Craftsman

Cover Appearance

106

3 Hole Crested Ridge see page 107

Arrowhead and Club Ornamental Tiles see page 107

Weight and cover based on pitches below 90º * All weights nominal.

32 PLAIN TILE RANGE

PLAIN TILE RANGE 33


ROSEMARY CLAY CRAFTSMAN How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

Drawing on the Rosemary heritage and pedigree, new Rosemary Clay Craftsman tiles combine warm, rustic colours with beautiful natural textures to create roofscapes of outstanding handcrafted

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof

character. Made from the finest selected clays,

Ornamental Tiles, Ridges and Finials

Craftsman tiles feature a variable hanging length, leading edge distortion, subtle textured surfaces and rich, natural colours, resulting in a tile of the highest handcrafted aesthetics, which accurately replicates the look of traditional old clay tiles.

106

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch Maximum Pitch (subject to fixing specification) Minimum Headlap below 90° at 90° Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 90° at 90º Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity below 90º at 90º

265 x 165mm 35º 90° 65mm 35mm 88mm 88mm 100mm 115mm 255mm 165mm 60 tiles/m2 52 tiles/m2

(all figures are net and do not allow for wastage)

Rosemary Craftsman, New development, Esher, Surrey

34 PLAIN TILE RANGE

Rosemary Clay Craftsman tiles were the perfect choice for housebuilder Beaufield Homes.With a reputation for developing prestige properties with high levels of craftsmanship and attention to detail, the authentic handmade look and beautiful natural textures of Craftsman were ideally suited.

Sanded finish

NEW

NEW

Penhurst 88

Ashcombe 89

Weight (approx.) per 1000 below 90º at 90º per pallet, including pallet (approx.) Battens Required (at max. gauge) below 90º Batten Size Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

Product Codes

1.11 tonnes 67kg/m2 58kg/m2 0.97 tonnes 10.0m/m2 38 x 25mm 40 x 2.65mm 864 9 96

113 - 115 PLAIN TILE RANGE 35


ROSEMARY CLAY CLASSIC How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

The Rosemary name is synonymous with clay plain tiles, adding Rosemary Classic, Red Holly Lodge, Highgate, London

distinction and character to pitched roofs for over 160 years. Today, a range of single and cross-camber tiles combine the quality of hand-crafted clay with the reliability of modern

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof

machine-made techniques. Produced from the finest clays,

Ornamental Tiles, Ridges and Finials

106

Rosemary is offered in a range of weathered, brindled and single colours that create striking and attractive roofs.

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch Maximum Pitch (subject to fixing specification) Minimum Headlap below 90° at 90° Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 90° at 90º Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity below 90º at 90º

265 x 165mm 35º 90° 65mm 35mm 88mm 88mm 100mm 115mm 255mm 165mm 60 tiles/m2 52 tiles/m2

(all figures are net and do not allow for wastage)

Rosemary, Medium Mixed Brindle, Private House, Belton, Lincolnshire

36 PLAIN TILE RANGE

Rosemary Clay tiles created the striking octagonal roof of ‘The Dovecote’ whilst also helping it blend in with surrounding older buildings, many of which have clay tiled roofs. Small format Rosemary tiles offered the versatility and flexibility to achieve decorative vertical details such as the tiling to the dormer faces and cheeks.

Cross Camber

Smooth finish

Sanded finish

NEW

Red 80

Light Mixed Brindle 81

Medium Mixed Brindle 82

Blue Brindle 87

Burnt Blend 91

Copper Brindle 93

Russet Mix 94

Dark Antique 95

Weight (approx.) per 1000 (Colour 93, 95) below 90º at 90º per pallet, including pallet (approx.) Battens Required (at max. gauge) below 90º Batten Size Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet (Colour 93, 95) Tiles/Pack Packs/Pallet

Product Codes

1.32 tonnes (1.11) 78kg/m2 (67) 68kg/m2 (58) 1.12 tonnes (1.00) 10.0m/m2 38 x 25mm 40 x 2.65mm 840 (880) 14 (11) 60 (80)

113 - 115 PLAIN TILE RANGE 37


HEATHLAND How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

A plain tile with an uneven leading edge, irregular sides and textured sanded surface, which provides a hand-made clay appearance.The tile combines this natural weathered look with the performance of a

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof

machine-made tile and therefore represents a cost

Ornamental Tiles, Ridges and Finials

106

effective option.To achieve this hand-made character a slight size variation has been purposely designed.

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch Maximum Pitch (subject to fixing specification) Minimum Headlap below 90º at 90º Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 90° at 90º Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity below 90º at 90º

265 x 165mm 35º 90° 65mm 35mm 88mm 88mm 100mm 115mm 248mm 165mm 60 tiles/m2 52 tiles/m2

(all figures are net and do not allow for wastage)

Heathland, Ember New Westbury development, Greenfields, Burghfield Common, Berkshire

Heathland, Ember Private House, Prestbury, Cheshire

The housebuilder specifically selected Heathland tiles in Ember for this impressive private house in Prestbury. The textured sanded surface of Heathland gives a pre-weathered look to the roof.

Through coloured

Autumn 23

38 PLAIN TILE RANGE

Sunset 24

Sanded finish

Ember 25

Weight (approx.) per 1000 below 90º at 90º per pallet, including pallet (approx.) Battens Required (at max. gauge.) below 90º Batten Size Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

Product Codes

1.29 tonnes 77kg/m2 67kg/m2 1.01 tonnes 10.0m/m2 38 x 25mm 40 x 2.65mm 768 16 48

113 - 115 PLAIN TILE RANGE 39


DOWNLAND How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

A cross cambered plain tile with a soft deckled leading edge and textured sanded surface, which provides a soft undulating appearance.Available in a choice of warm natural colours, it possesses the

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof

rich visual character of clay, whilst offering modern

Ornamental Tiles, Ridges and Finials

106

standards of performance and economy.

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch Maximum Pitch (subject to fixing specification) Minimum Headlap below 90° at 90° Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 90° at 90º Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity below 90° at 90º

265 x 165mm 35º 90° 65mm 35mm 88mm 88mm 100mm 115mm 248mm 165mm 60 tiles/m2 52 tiles/m2

(all figures are net and do not allow for wastage)

Downland, Manor House Mix with Hedgerow Brown banding Public house, Chesterfield, Derby 40 PLAIN TILE RANGE

The Tom Cobleigh owned Donkey Derby pub in Chesterfield makes a feature of its large roof, attracting interest and attention on its busy roadside site with decorative banded tiling using Downland tiles in Manor House Mix and Hedgerow Brown.Three-hole crested ornamental ridges and balltop finials complete the rooftop decoration.

Through coloured

Hedgerow Brown 18

Sanded finish

Manor House Mix Woodland Brown 21 20

Weight (approx.) per 1000 below 90° at 90º per pallet, including pallet (approx.) Battens Required (at max. gauge) below 90° Batten Size Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

Product Codes

1.29 tonnes 77kg/m2 67kg/m2 1.01 tonnes 10.0m/m2 38 x 25mm 40 x 2.65mm 768 16 48

113 - 115 PLAIN TILE RANGE 41


PLAIN TILE How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

A cross-cambered concrete tile of traditional RedLine Plain Tile Ventilation Units (see page 102) provides unobtrusive ventilation and are available in most Plain Tile colours.

appearance, designed to be easy to fix. Available in a wide range of natural colours to offer a variety of design options.

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof Ornamental Tiles, Ridges and Finials

106

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch Maximum Pitch (subject to fixing specification) Minimum Headlap below 90° at 90º Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 90° at 90° Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity below 90° at 90º

268 x 165mm 35º 90° 65mm 35mm 88mm 88mm 100mm 115mm 248mm 165mm 60 tiles/m2 52 tiles/m2

(all figures are net and do not allow for wastage)

Plain Tile, Breckland Brown Supermarket, Ashbourne, Derbyshire

Sainsbury’s town stores are individually designed to fit into their local surroundings. Hadfield Cawkwell Davidson architects specified Redland Plain Tiles for the pitched roof, canopies and porticoes of this store because they were an excellent match for the surrounding area. Sanded

Acrylic coated

Granular

Through coloured

NEW

Brown 02

42 PLAIN TILE RANGE

Antique Red 03

Cotswold 12

Natural Red 27

Slate Grey 30

Terracotta 34

Tudor Brown 36

Farmhouse Red 39

Breckland Brown 52

Breckland Black 53

Rustic Red 78

Weight (approx.) per 1000 below 90° at 90º per pallet, including pallet (approx.) Battens Required (at max. gauge) below 90° Batten Size Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

Product Codes

1.29 tonnes 77kg/m2 67kg/m2 1.01 tonnes 10.0m/m2 38 x 25mm 40 x 2.65mm 768 16 48

113 - 115 PLAIN TILE RANGE 43


DUOPLAIN How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

DuoPlain combines the classic proportions and good looks of traditional plain tiles with all the time and cost-saving benefits of a modern, large-format, interlocking tile. Engineered for strength, ease of handling and ease of installation, it fulfils the three main demands of a modern roofing site.Available in five popular colours,

70 - 71 72 - 73 90 - 95, 98 87 102 - 105

Adding character to your roof

Tuscan Red, Flame Red, Rustic Brown, Charcoal Grey and Rustic Red, DuoPlain

Ornamental Tiles, Ridges and Finials

106

also comes with a full range of matching fittings and accessories.

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch

268 x 330mm 25º

(The minimum pitch is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, please contact the Technical Solutions Hotline on 08708 702595)

Maximum Pitch (subject to fixing specification) Minimum Headlap Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Hanging Length (approx.) Cover (all figures are net and do not allow for wastage) Linear cover of 1 tile Covering capacity at max. gauge Weight (approx.) per 1000 at max.gauge per pallet, including pallet (approx.) Battens Required (at max. gauge) Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

DuoPlain’s distinctive double camber gives the appearance of traditional plain tiles. Shown here with the specially designed RedLine DuoPlain Ventilation Tile for unobtrusive roofspace ventilation.

DuoPlain, Charcoal Grey Redrow Homes, Stone, Staffordshire

Painted

DuoPlain tiles helped Redrow Homes to build quicker and therefore improve cost efficiencies on this new development in Staffordshire.The tile design meant contractors needed to fit only a third of the tiles to achieve the authentic look of a traditional double-lapped plain tile roof. Tuscan Red 11

44 PLAIN TILE RANGE

Flame Red 38

Rustic Brown 40

Acrylic coated

90° 80mm 95mm 173mm 188mm 243mm 300mm 17.7 tiles/m2 3.11 tonnes 55kg/m2 0.91 tonnes 5.26m/m2 38 x 25mm 50 x 25mm 45 x 3mm 288 6 48

Through coloured

Charcoal Grey Rustic Red 78 77

Product Codes

113 - 115 PLAIN TILE RANGE 45


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 46

PROFILE RANGE

Based on traditional designs, the profile range comprises precision-made interlocking clay and concrete tiles in a wide variety of colours and finishes. Shapes, colours and textures can be selected from this extensive range to enhance the appearance of virtually any building design. As well as their aesthetic appeal, interlocking clay and concrete tiles are designed for ease of laying, which saves installation time on site.

As well as their aesthetic appeal, interlocking clay and concrete tiles are designed for ease of laying, which saves installation time on site.

Manufactured to stringent quality standards, the profile range is suitable to be laid at low pitches – Regent having a minimum pitch of 12.5º.

HOW ARE YOU VENTILATING YOUR ROOF? Eaves Ventilation Systems 72 - 73 Ridge Ventilation Systems 90 - 95, 98 Top Edge Abutment Ventilation System 87 Ventilation Tiles 100, 104

Landmark Old Hollow Cathedral Double Clay Pantile Clay Pantile Pantile

RedLine Ventilation Tiles see page 100

DryVent Ridge System see page 90

Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

Dry Hip System see page 78

Regent

Renown

Norfolk Pantile

49 Tile

52

54

56

57

58

59

60

61

Min. Pitch 30º

22.5º

15º

17.5º

15º

17.5º

12.5º

17.5º

17.5º

17.5º

38kg/m2

46kg/m2

46kg/m2

48kg/m2

43kg/m2

46kg/m2

43kg/m2

46kg/m2

49kg/m2

9.7 tiles/m2

9.7 tiles/m2

9.7 tiles/m2

9.7 tiles/m2

9.7 tiles/m2

16.3 tiles/m2 16.3 tiles/m2

Rich, long lasting clay colours on a Double Roman profile

Traditional Double Pantile

Traditional Double Roman

Deep Low profile section, tile with bold roll tile strong lines

Appearance Long-lasting Natural

Cloaked Verge System see page 74

50 Double Roman

50

Cover 16.4 tiles/m2 12.2 tiles/m2 9.7 tiles/m2

74 - 77 78 - 81 86 - 88 90 - 99 116 - 117

Grovebury

Page No. 48

Weight* 33kg/m2

HOW ARE YOU PREVENTING STORM DAMAGE?

Landmark Double Roman

good looks and weathered colours

Rich, long clay lasting clay interlocking colours on Pantile a Double Pantile

Classic single Pantile

Small, low profile tile with unique camber

Weight and cover based on pitches below 90°. All tiles must be laid straight bonded, from right to left. * All weights nominal.

46 46 AA PROFILE RANGE

AA 47 PROFILE RANGE 47


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 48

OLD HOLLOW CLAY PANTILE

NEW How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ventilation Tiles

Redland Old Hollow Clay Pantiles are traditional overlapping single pantiles manufactured to have a

70 - 71 72 - 73 104

How are you preventing storm damage?

reclaimed appearance on the roof and backed by the Redland 15 Year Roof System Guarantee.

Eaves,Verge and Tile Clips

117

With its distinctive pattern of rolls and troughs, Old Hollow perfectly replicates the traditional old English pantile shape, producing roofscapes of outstanding charm and character. Old Hollow is available in two colours, both with a random coloured finish and textured surface, giving an aged appearance from day one.

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 30° 35° Maximum Pitch (subject to fixing specification) Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 35° 35° and over Hanging Length (approx.) Cover Linear cover of 1 tile below 35° 35° and over Covering capacity below 35° 35° and over

343 x 242mm at 48mm headlap at 38mm headlap 90º 295mm 295mm 305mm 310mm 206mm 202mm 16.4 tiles/m2 16.2 tiles/m2

(all figures are net and do not allow for wastage)

Old Hollow Clay Pantile, Vintage Red

Weathered finish

Weight per 1000 below 35° 35° and over per pallet, including pallet (approx.) Battens Required at max. gauge below 35° 35° and over Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

2.0 tonnes 33kg/m2 32kg/m2 0.70 tonnes 3.39m/m2 3.28m/m2 38 x 25mm 50 x 25mm 55 x 2.65mm* 336 6 5

* Annular ring-shanked nail

Vintage Blue 60

48 PROFILE RANGE

Vintage Red 80

Product Codes

116 - 117 PROFILE RANGE 49


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 50

CATHEDRAL CLAY PANTILE How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

Cathedral Clay Pantiles combine the character of a natural clay tile with the performance of a modern interlocking tile, to produce a striking and attractive roof. Precision manufactured using the latest in clay

70 - 71 72 - 73 92 87 104

How are you preventing storm damage?

technology, Cathedral is available in three rich

Verge System Ridge Systems Eaves,Verge and Tile Clips

colours,Terracotta, Brindle and Black, that will mellow with age.

80 92 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 22.5° 30° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

409x 264mm at 59mm headlap at 49mm headlap 90° 69mm 340mm 350mm 360mm 359mm 224mm 12.4 tiles/m2

(all figures are net and do not allow for wastage)

Cathedral Clay Pantile, Terracotta

Engobe finish Smooth finish

3.1 tonnes 38kg/m2 0.91 tonnes 2.74m/m2 38 x 25mm 50 x 25mm 60 x 2.65mm* 288 6 48

* Annular ring-shanked nail with washer (Included with tile)

Black 79

50 PROFILE RANGE

Weight per 1000 at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

Terracotta 80

Brindle 82

Product Codes

116 - 117 PROFILE RANGE 51


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 52

LANDMARK DOUBLE PANTILE How are you ventilating your roof? Landmark Double Pantiles have a special surface finish that means they look great from day one and will retain their intended look for at least 25 years. Landmark Double Pantiles are a cost-effective alternative to clay pantiles and enable you to design in context with the traditional appeal of clay without the usual cost penalties.

Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

74 - 77 78 - 81 86 - 88 90 - 99 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 15° 17.5° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 17.5° 17.5° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

418 x 332mm at 100mm headlap at 75mm headlap 90° 125mm 293mm 318mm 343mm 394mm 300mm 9.7 tiles/m2

(all figures are net and do not allow for wastage)

A low maintenance roof, thanks to the Redland mechanically fixed ridge and verge systems, is an added attraction for homebuyers.

Landmark Double Pantile, Terracotta Brindle Private Houses, Coach House Mews, Bournemouth 52 PROFILE RANGE

Developer Bryant Homes chose Landmark Double Pantiles for this development because the tiles provide an attractive and cost-effective alternative to clay. The long-lasting colour of the tiles was also a key factor in their decision to specify Landmark.

Through coloured ColourFusionTM

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

4.7 tonnes 46kg/m2 1.00 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 70 x 3.75mm 210 35 6

* All weights nominal

Rich Terracotta 42

Terracotta Brindle 43

Brown Brindle 44

Product Codes

116 - 117 PROFILE RANGE 53


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 54

LANDMARK DOUBLE ROMAN How are you ventilating your roof? Landmark Double Roman tiles combine our special long-lasting Landmark surface finish with the popular Double Roman profile.Available in two authentic clay colours, they are ideal for maintaining the look of a traditional Double Roman roof at a considerable saving over new or reclaimed clay.

Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge Systems Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

74 - 77 78 - 81 86 - 88 90 - 99 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 17.5° 22.5° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 22.5° 22.5° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

418 x 330mm at 100mm headlap at 75mm headlap 90° 125mm 293mm 318mm 343mm 397mm 300mm 9.7 tiles/m2

(all figures are net and do not allow for wastage)

Landmark Double Roman, Terracotta Brindle

Through coloured

Terracotta Brindle 43

54 PROFILE RANGE

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet ColourFusionTM

Brown Brindle 44

4.7 tonnes 46kg/m2 1.14 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 60 x 3.35mm 240 40 6

* All weights nominal

Product Codes

116 - 117 PROFILE RANGE 55


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 56

GROVEBURY

50 DOUBLE ROMAN How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

74 - 77 78 - 81 86 - 88 90 - 99 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap Through coloured 15° 17.5° Granular 22.5° 30° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Through coloured below 17.5° 17.5° and over Granular below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

418 x 332mm at 100mm headlap at 75mm headlap at 100mm headlap at 75mm headlap 90° 125mm 293mm

A concrete interlocking tile that uses gentle flowing lines to create a double pantile appearance.They are quicker and easier to lay than single pantiles.

Granular

Granular

Through coloured

Through coloured

NEW

318mm 343mm 318mm 343mm 394mm 300mm 9.7 tiles/m2

A classic interlocking concrete tile with a distinctive ‘Roman’ profile. It is available in a wide range of colours to blend harmoniously with any environment.

Brown 02

Antique Red 03

Anthracite 13

Brown 02

Antique Red 03

Cotswold 12

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

56 PROFILE RANGE

Size (overall) Minimum Pitch and Headlap Through coloured 17.5° 22.5° Granular 22.5° 30° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Through coloured below 22.5° 22.5° and over Granular below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

418 x 330mm at 100mm headlap at 75mm headlap at 100mm headlap at 75mm headlap 90° 125mm 293mm 318mm 343mm 318mm 343mm 397mm 300mm 9.7 tiles/m2

(all figures are net and do not allow for wastage)

5.10 tonnes 48kg/m2 1.12 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 70 x 3.75mm 216 36 6

Slate Grey 30

Terracotta 34

Tudor Brown 36

Slate Grey 30

Terracotta 34

Tudor Brown 36

* All weights nominal

Product Codes

Technical Data

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

4.58 tonnes 43kg/m2 1.17 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 60 x 3.35mm 252 42 6

* All weights nominal

116 - 117

Farmhouse Red 39

Breckland Brown 52

Breckland Black 53

Farmhouse Red 39

Breckland Brown 52

Breckland Black 53

Product Codes

116 - 117 PROFILE RANGE 57


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 58

REGENT

RENOWN How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Top Edge Abutment Ventilation System Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 87 100, 104

How are you preventing storm damage? Verge System Hip Systems Abutment Systems Ridge Systems Eaves,Verge and Tile Clips

74 - 77 78 - 81 86 - 88 90 - 99 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap Through coloured 12.5°* 17.5° Granular 22.5° 30°

418 x 332mm at 100mm headlap at 75mm headlap at 100mm headlap at 75mm headlap

Traditionally shaped, this concrete tile provides a striking, bold effect that can be laid as low as 12.5º. Manufactured with a choice of through coloured or granular finishes to easily blend into both historical and modern environments.

A neat low-profile tile that comes in a variety of through coloured and granular faced finishes. Designed to blend unobtrusively into any environment.

Technical Data

*When roof slope includes inclined valleys, minimum pitch is 15º

Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Through coloured below 17.5° 17.5° and over Granular below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

90° 125mm 293mm Granular

Through coloured

Granular

Acrylic coated

Through coloured

Acrylic coated

NEW

318mm 343mm 318mm 343mm 397mm 300mm 9.7 tiles/m2

Brown 02

Antique Red 03

Slate Grey 30

Brown 02

Antique Red 03

Cotswold 12

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

4.89 tonnes 46kg/m2 1.25 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 75 x 3.75mm 252 42 6

Terracotta 34

Tudor Brown 36

Farmhouse Red 39

Slate Grey 30

Terracotta 34

Tudor Brown 36

Anthracite 13

Size (overall) Minimum Pitch and Headlap Through coloured 17.5° 22.5° Granular 22.5° 30° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Through coloured below 22.5° 22.5° and over Granular below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

418 x 330mm at 100mm headlap at 75mm headlap at 100mm headlap at 75mm headlap 90° 125mm 293mm 318mm 343mm 318mm 343mm 397mm 300mm 9.7 tiles/m2

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

4.58 tonnes 43kg/m2 1.11 tonnes 2.92m/m2 38 x 25mm 50 x 25mm 50 x 3mm 240 40 6

* All weights nominal

* All weights nominal

Product Codes 58 PROFILE RANGE

116 - 117

Breckland Brown 52

Breckland Black 53

Rustic Red 78

Farmhouse Red 39

Breckland Brown 52

Rustic Red 78

Product Codes

116 - 117 PROFILE RANGE 59


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 60

NORFOLK PANTILE

49 TILE How are you ventilating your roof? Vapour Permeable Underlays Eaves Ventilation Systems Ridge Ventilation Systems Ventilation Tiles

70 - 71 72 - 73 90 - 95, 98 100, 104

How are you preventing storm damage? Hip Systems Ridge Systems Eaves,Verge and Tile Clips

78 - 81 90 - 99 117

Specification Support GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available PRODUCT VISUALISER www.redland.co.uk/viewmaster SAMPLES www.redland.co.uk/samples or call 08705 601000

Technical Data Size (overall) Minimum Pitch and Headlap 17.5° 22.5° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing below 22.5° 22.5° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

381 x 227mm at 100mm headlap at 75mm headlap 90° 125mm 256mm

A classic single pantile shape in a modern interlocking concrete tile with a weathertight performance.Available in a range of subtle through coloured finishes.

281mm 306mm 362mm

A visually appealing, small interlocking cambered tile that has defined the roofscapes of London and the South East for more than 50 years.This tile has been improved and its ease of installation is a major benefit in new build or re-roofing applications.Available in a range of attractive colours.

Granular

Through coloure

Acrylic coated

200mm 16.3 tiles/m2

(all figures are net and do not allow for wastage)

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

2.91 tonnes 46kg/m2 1.33 tonnes 3.26m/m2 38 x 25mm 50 x 25mm 45 x 3mm 450 50 9

Brown 02

Through coloured

Antique Red 03

Size (overall) Minimum Pitch and Headlap Through coloured 17.5° 25° Granular 22.5° 30° Maximum Pitch (subject to fixing specification) Maximum Headlap Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing Through coloured below 25° 25° and over Granular below 30° 30° and over Hanging Length (approx.) Cover Linear cover of 1 tile Covering capacity at max. gauge

382 x 226mm at 100mm headlap at 75mm headlap at 100mm headlap at 75mm headlap 90° 125mm 257mm 282mm 307mm 282mm 307mm 360mm 200mm 16.3 tiles/m2

(all figures are net and do not allow for wastage)

Slate Grey 30

Terracotta 34

Tudor Brown 36

Terracotta 34

Tudor Brown 36

* All weights nominal

Slate Grey 30

Technical Data

Farmhouse Red 39

Weight per 1000* at max. gauge (approx.) per pallet, including pallet (approx.) Battens Required at max. gauge Batten Size Rafter centres up to 450mm Rafter centres up to 600mm Nail Size for Tiles Number of Tiles/Pallet Tiles/Pack Packs/Pallet

3.12 tonnes 49kg/m2 1.42 tonnes 3.26m/m2 38 x 25mm 50 x 25mm 50 x 3mm 450 50 9

* All weights nominal

Product Codes 60 PROFILE RANGE

116 - 117

Farmhouse Red 39

Breckland Brown 52

Breckland Black 53

Breckland Brown 52

Rustic Red 78

Product Codes

116 - 117 PROFILE RANGE 61


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 62

REDLAND METAL ROOFING Nullam diam lacus, auctor in, faucibus vel, ultricies

Lightweight roofingheavyweight performance

id, sapien. Donec pede. Pellentesque blandit varius

As TerraPLEGEL Hi Load is mechanically fixed and spans in long lengths it is difficult to remove and damage

diam. Mauris accumsan pede eu neque. Cras eleifend, elit at gravida sodales, pede libero

For over 25 years this lightweight metal roofing

consectetuer felis, id tempus justo risus sed orci.

roofs around the world.

Donec mollis quam non mauris. Mauris nec metus quis neque facilisis pellentesque. Cras vitae libero. Nullam erat. Nunc quam ipsum, vulputate sed, semper eget, auctor nec, turpis.

• Weighing as little as 4.8 kg/m2, makes it ideal for

system has been a popular choice for pitched

flat to pitched roof conversions • Manufactured in long lengths up to 6.4 metres, fewer battens/purlins are required compared with other tile-effect systems • Cost-effective and quick and easy to fix, which reduces labour costs • 10º minimum pitch • Offered in a variety of profiles, colours, finishes and thicknesses, Redland Metal Roofing suits most pitched roofs • Exceptional strength allows full roof walkability • Awarded British Board of Agrément certificate no. 90/2509 and complies with BS 5427-1: 1996 • Guaranteed for up to 30 years

For more information on the Redland Metal Roofing range: Request a brochure by telephoning our Customer Service Hotline on 08705 601000 or visit www.redland.co.uk/brochures

TerraPLEGEL Hi Load, Dutch Pantile, Grey Post-war modular housing 62 REDLAND METAL ROOFING

An eaves to ridge sheet means quicker installation and less supporting structure

TerraPLEGEL, Dutch Pantile, Red 740 and Dark Green 830. Flat to pitched roof conversions, Newham, London

The London Borough of Newham chose the Redland Metal Roofing system for flat-to-pitch conversions on these apartment blocks.The light weight, coupled with its close resemblance to profiled roof tiles, made it an ideal refurbishment solution.

REDLAND METAL ROOFING 63


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 64

SOLAR WATER HEATING SYSTEMS ST 4 and ST 6 Solar Water Heating Systems The ST 4 and ST 6 solar water heating systems harness the power of the sun to provide environmentally friendly hot water. The hot water generated reduces the energy demand on the conventional boiler system. • A correctly sized Solar Water Heating System can generate up to 70% of the household hot water requirement. • Fully integrated roof solution, providing superb aesthetics. • Market-leading wind uplift security and weathertightness (flashings integrated to the panels). ST 6 Solar Water Heating System

• Redland 15 year Roof System Guarantee. • Designed to comply with BS 6399-2:1997 and BRE Digest 489(2004) for wind loading and BS 476-3:2004 for resistance to external fire spread. Fully tested in accordance with pr EN 15601 for wind-driven rain.

Specification Support SOLAR HOT WATER SYSTEM SPECIFICATION AND PERFORMANCE www.redland.co.uk/ecomaster or call 08708 702595 GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 PRODUCT VISUALISER www.redland.co.uk/viewmaster

Our Solar Water Heating Systems are easy to install

ST 4 Solar Water Heating System

64 SOLAR RANGE

SOLAR RANGE 65


RED1094_GTRS_GB_Range.qxd

30/1/09

17:38

Page 66

SOLAR WATER HEATING SYSTEMS Working Principles ST4 or ST6 solar water heating panel

The sun’s heat is collected, stored and used

Technical Data – Panel

when needed. 1

A typical Solar Water Heating System layout

Pipes run between panel head and upper gutter so they can penetrate roof where required

is shown detailing the various components.

Type

Upper gutter

Absorption - Ratio of transformation from short wave to long wave radiation (absorber).

> 93%

Heat emission - Ratio of radiation as heat losses (absorber)

<5%

Absorber Material

Upper panel fixing screw

An electronic controller constantly compares

2

ST4 or ST6 Panel

the temperature of the liquid in the panel

Apron flashing Gutter Support Batten

Lower gutter

with the temperature of the water in the

Lower panel fixing screw

cylinder. When the temperature difference

Underlay

equals a pre-defined value, the liquid is

Rafter

Upper fixing bar with screws and packing pieces

Panel position determined by tile and batten gauge

the cylinder in the same way as a central

3

A conventional heating system is still

8

Panel schematic of ST4

required to supplement the solar panels for

270

those periods of the year when there is not

2376 2190 (Tile Opening Width) 2030

Additional Components Redland can also specify and offer the components required for connecting the panel pipes to the hot water system, this includes, connectors, flexible pipes, pumps, control stations, remote displays, data loggers, expansion vessels and heating medium (antifreeze solutions).

66 SOLAR RANGE

Typical Tile Opening Slope-height) 2150 to 2360

2375 2035 70

Flexible S/S Twin Pipe Coil

4

Pump and Control Station

5

Expansion Vessel

6

Datalogger (optional)

7

Remote Display (optional)

8

High Sensor

9

Low Sensor

10 Hot water cylinder (not supplied) 11 Boiler (not supplied)

Sensor connecting wires Typical Tile Opening Slope-height) 2150 to 2360

3

Connectors

270

ST4 or ST6 Panel (with flexible pipes) and Installation Pack

120kg /panel 180kg /panel 27.6kg/m2 27.9kg/m2 700mm

Cold feed Hot water Expansion Tank Pipe Wires for optional equipment

Collector and boiler flow pipes

Redland Slate and Profile ranges

Maximum roof pitch

Not more than the maximum tile pitch

Minimum roof pitch

22º and not less than the minimum tile pitch

3369 3183 (Tile Opening Width) 3023

2375 2035

2

10 years

Maximum Rafter spacing

Panel schematic of ST6 Collector Sensor

25 years

Panel Performance Guarantee

Tile compatibility

KEY 1

Panel Design Lifespan

Installed Panel weight ST 4 ST 6

7

240

Panel Fixing Tool Pack – Contains the tools required when fixing the Panel Installation Pack, including screwdriver socket, driver bit and drill bit.The same pack can be used for fixing several panels.

6

90% 4.9 kJ/(m2K)

Technical Data – Roof Integration

Specification Support SOLAR HOT WATER SYSTEM SPECIFICATION AND PERFORMANCE www.redland.co.uk/ecomaster or call 08708 702595 GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 PRODUCT VISUALISER www.redland.co.uk/viewmaster

70

Panel Installation Pack – Contains all parts required to perfectly integrate and securely fix the panel within the roof. One pack is required per panel.

11

10

> 90 %

Nominal Panel Weight (empty) ST 4 ST 6

240

Solar Water Heating Panel – Flat Plate aluminium box with a glass covering, dark in colour to help absorb heat and fullyinsulated inside to minimise heat loss.The panels possess integrated flashings (side gutters, upper and lower gutter, front apron flashing) to ensure that the roof is weathertight. Two panel sizes are available. Panels can be connected together. The system performance is directly proportional to the panel surface area.

9

4

Redland Specific Products

> 91 %

Radiation transmission factor Ratio of transmission through the solar-glazing no visible light.

Performance – Panel Performance

enough sun. 5

Light transmission factor Ratio of transmission through the solar-glazing visible light.

Thermal capacity or thermal inertia The quantity of heat required to raise the temperature of the absorber by one degree. A low value is advantageous in cloudy conditions.

Lower fixing bar with screws and packing pieces

heating boiler.

Copper

Total Radiation transmission Ratio of transmission through the solar-glazing.

circulated through the panel and the lower coil in the cylinder, heating the water in

Flat plate collector

Tile support & clip batten

Collector and boiler return pipes

Active panel area

Frame

Apron Flashing

Gutter Flashing

SOLAR RANGE 67


SPECIFIC TION SUPPORT

EVERYTHING YOU NEED UNDER ONE ROOF

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

From roof tiles and underlays to eaves systems and ridges, we have a comprehensive range of roof products and systems. All elements of our roofs are carefully designed, tested and manufactured to give value, visual appeal and a long-lasting weathertight performance.

12

4 6 11

68 INTRODUCTION

Tiles, Slates & Metal Roofing 18 - 65

2

Underlays 70 - 71

3

Eaves Systems 72 - 73

4

Verge Systems 74 - 77

5

Hip Systems 78 - 83

6

Valley Systems 84 - 85

7

Abutment Systems 86 - 88

8

Ridge Systems 90 - 99

9

Ventilation Tiles 100 - 105

8

1

2

1

10

9 3

7

5

10

Clips & Nails 110 - 117

11

Internal/External Angles 115

12

Ornamental Tiles 106 - 107

INTRODUCTION 69


SPECIFIC TION SUPPORT

SPIRTECH 250, VELTITECH & UNDERLAY SUPPORT TRAY

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Eaves (Spirtech 250) (see p.74-75 for alternative Eaves solutions)

Ridge (Spirtech 250) (see p.90-99 for alternative Ridge Solutions)

Spirtech 250 is a high quality, quadruple layer vapour permeable underlay. It provides exceptional strength and durability, with excellent vapour transmission properties. Veltitech is a high quality alternative to bituminous felt, with market-leading strength and durability. The Underlay Support Tray provides both continuous support for the underlay at the eaves and a UV resistant drip into the gutter. Features Spirtech 250 • With its high vapour transmission capacity, excellent nail hole sealing and abrasive resistant surface, Spirtech 250 is ideal for all types of pitched roofing • Manufactured from spun bond polypropylene with an additional reinforcement grid, it is strong and durable yet lightweight and easy to install Veltitech • Robust construction allows Veltitech to withstand the highest wind loading found in the UK • Passes GS BAU Step Through Test and has a matt non-slip surface • Absorbent fleece on the back of the underlay helps to prevent condensation dripping onto the insulation

70 UNDERLAY

Underlay Support Tray • Replaces the need for a timber tilting fillet or additional length of UV resistant underlay • Easy to install • Guaranteed weathertight and secure for 15 years Authority & Performance • Spirtech 250 and Veltitech comply with BS 5250:2002, BS 5534:2003 and BS EN 13859-1:2005 • Awarded British Board of Agrément Certification, certification numbers 05/4283 and 06/4306 • Backed by Redland’s 15-year product guarantee • Mechanically fix all tiles at the eaves Compatibility • Spirtech 250 and Veltitech can be used with the complete Redland range of tiles and slates • Not adversely affected by any of the standard construction materials used in the roof or by any of the commonly used timber preservatives • Eaves Clips and Reform Eaves Filler Units can be easily fixed through the Underlay Support Tray • Fascia board height will vary with rafter pitch, roof construction and tile type. Please contact Technical Solutions • Spirtech 250 can be used without Eaves Ventilation when used in conjunction with a well sealed ceiling and ridge or other high level ventilation

Guidance Notes: Spirtech 250 • Spirtech 250 must always be used in accordance with Redland’s recommendation for correct ventilation. • All penetrations in the ceiling should be well sealed. • Leave the underlay short of the apex by 30mm where the insulation is either installed at ceiling level or rebated between the rafters. • Ventilate at high-level to a minimum value of 5,000mm2 per metre using Rapid Vented Ridge or DryVent Ridge. However, tile vents can be used if it is not possible to install a dry-fix ventilated ridge system. • When laid unsupported Spirtech 250 must be draped across supports with a 10mm drape and not pulled taut. • At the eaves avoid carrying Spirtech 250 into the gutter by fitting Underlay Support Trays. • Spirtech 250 must be stored flat or upright on a clean, level surface, under cover and out of direct sunlight. • It is best practice to apply the external roof covering as soon as the installation of Spirtech 250 is complete. Guidance Notes: Veltitech • When fitted in a roof with insulation at ceiling level, the roof void should be ventilated to a capacity of 10,000mm2/m at low level and if pitch is 15º or lower this should be increased to 25,000mm2/m.This should be installed on both sides of the roof. • For buildings with a rafter span over 10m or roof pitch over 35° the roof void should also be ventilated to a capacity of 5,000mm2/m. • It is best practice to apply the external roof covering as soon as the installation of Veltitech is complete. Guidance Notes: Underlay Support Tray • Minimum pitch will depend on the minimum pitch of the roof covering. • Maximum pitch is 55° for use with RedVent 25 Over-Fascia Vent or 80° without. A softwood clip batten should always be used when using a Redvent 25 Over-Fascia Vent. • Fix Underlay Support Tray to top of fascia board at centres not greater than 300mm. Underlay Support Trays must butt up against one another and not overlap. For Cambrian, DuoPlain and plain tiles remove section of tray by cutting along the score line. Lay underlay over Underlay Support Tray with bottom edge in line with top of fascia. Components for Underlay Support Tray • 1.5 metre lengths (uPVC-black)

Technical Data Spirtech 250

Veltitech

Colour

Dark Grey

Dark Grey

Material

4 layer Spunbond Polypropylene fleece, Polypropylene grid, Polypropylene vapour transmission film

3 layer Polypropylene mesh, Polypropylene Coating, Spunbond Polypropylene fleece

Weight

152 g/m2

185 g/m2

Roll length

50 m

30 m

Roll width

1.5 m

1.5 m

Roll area

75 m2

45 m2

Physical Properties

Test Method

Spirtech 250

Veltitech

Water vapour permeability

DIN 52 615

900g/m2.24 hrs

-

Water vapour resistance

BS 7374

<0.25 MNs/g

-

Tensile strength - along the roll - across the roll

BS EN 12311-2 BS EN 12311-2

450 N / 5cm 360 N / 5cm

650 N / 5cm 650 N / 5cm

Nail tear force - along the roll - across the roll

BS EN 12310-2 BS EN 12310-2

340 N 360 N

300 N 300 N

Resistance to water penetration

BS EN 20811

3.0 m

3.0 m

Fire rating

BS EN 13501-1

E

E

Resistance to ultraviolet (UV) light

BS EN 1297

4 months

4 months

UNDERLAY 71


SPECIFIC TION SUPPORT

REDVENT EAVES VENTILATION SYSTEM

REDVENT 25 OVER-FASCIA VENT

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

The RedVent Eaves Ventilation System provides continuous over-fascia eaves ventilation for use when insulation is laid between or on top of the horizontal ceiling joists. Features • Ventilates to comply with BS 5250, therefore reducing the risk of harmful condensation in the roof • Guaranteed weathertight and secure for 15 years • Awarded British Board of Agrément Certification, certificate number 88/2000 • Suitable for rafter spacing between 350-600mm centres (subject to pack used). Use extension trays where the top of the insulation is greater than 450mm from the fascia when measured up the rafter • Removes the need for unsightly grilles in the soffit board which over time could become clogged • Eliminates the need for a tilting fillet and reduces the required height of the fascia board • Can be installed with or without a soffit board Compatibility • Suitable for use with most pitched roofing materials • Compatible with all of the Redland range of Eave Tile Clips • Where Eaves Clips or Reform Eaves Filler Units are required for use with a particular tile profile, it is acceptable to fix them through the Fascia Grille of the RedVent Eaves Ventilation System Performance • Minimum pitch will depend on the minimum pitch of the roof covering • Maximum pitch varies with tile used. Please contact Technical Solutions Hotline 08708 702595 • The effective ventilation area per metre run of eaves is 14,600mm2 • Mechanically fix all tiles at the eaves • Fit to straight and level softwood fascia

72 EAVES

The RedVent 25 Over-Fascia Vent provides unobtrusive continuous ventilation at the eaves for use where the insulation is installed either between or above the rafters. Features • Ventilates to comply with BS 5250, therefore reducing the risk of harmful condensation in the roof • Guaranteed weathertight and secure for 15 years • Used for any combination of rafter spacing • Can be installed with or without a soffit board • Eaves closure is achieved for Regent, Grovebury, Landmark Double Pantile and Norfolk Pantile by specifying the corresponding Reform Eaves Filler Unit • Eaves closure is achieved for Old Hollow and Cathedral Clay Pantiles by specifying the corresponding Comb Filler Unit

Compatibility • Suitable for use with most pitched roofing materials • Where Eaves Clips, eaves filler units or underlay support tray are required a 25mm x 25mm softwood clip batten should be secured through the RedVent 25 Over-Fascia Vent into the fascia board with 90mm x 3.35mm galvanised nails Performance • Minimum pitch will depend on the minimum pitch of the roof covering • Maximum pitch varies with tile used. Please contact Technical Solutions Hotline 08708 702595 • The effective ventilation area per metre run of eaves is 25,000mm2

RedVent 25 Over-Fascia Vent, eaves 15º pitch (Grovebury) Guidance Notes • Install a 4mm thick tilting fillet with a positive fall to support underlay over the Fascia Vent. • Do not extend underlay into the gutter unless 25mm spacer blocks are positioned behind the gutter brackets. • Suitable for softwood fascia boards 25mm thick and above. • No rafter tray required when underlay is fully supported by insulation. • For fascia board heights contact Technical Solutions. • The gutter’s size and position will need to be calculated to ensure that rainwater discharges directly into it. Components Each RedVent 25 Over-Fascia Vent pack contains: • 12 Fascia Grilles (Polypropylene – black) sufficient for 6 metres of eaves.

EAVES 73


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

CLOAKED VERGE SYSTEM The Cloaked Verge System continues the tiling over the gable end using a one piece concrete tile. The system has very high resistance to storm damage and with no mortar required it removes concerns about mortar failure.

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Concrete Cloaked Verge System with Vertical Tiling (Regent)

Concrete Cloaked Verge System with Timber Sarking (Regent)

Guidance Notes • When setting out the roof, the verge overhang should be the same at both verges.The use of Half Tiles (Two Thirds Tile for Cathedral) in each course will allow the overhang to be reduced to a minimum. • Cloaked Verge Tiles are not suitable for raking verges. • Every Cloaked Verge Tile must be nail fixed, and the integral nylon plug must interlock with the Cloaked Verge Tile in the course below. • The left-hand Cloaked Verge Tile on the eaves course must be clipped to the adjacent tile using a ‘C’ clip (9179).This is supplied in every Block-end Ridge Tile pack (not applicable to Cathedral). • Finish ridge with Block End Ridge Tiles. • An undercloak should be installed between the battens and the structure, touching the inside face of the cloaked verge tile, to prevent bird ingress. • At top edge abutments, a lead flashing should dress down the face of the cloak to provide a full weathertight covering.The flashing length will be dependent on the rafter pitch. • In cases where no batten end fixing is available on roof pitches of 30º and above, a second batten is required to support the main batten. It is essential to secure the second batten over at least two rafters. • Where timber sarking is used over the main roof area, the tiling battens should rest on the external brickwork or cladding (see detail shown). On overhanging verges, the final counterbatten should be 6mm thinner to allow for undercloak. • At the eaves, for Landmark Double Pantile, Regent and Grovebury Tiles, Reform Eaves Filler Units should be cut to fit the inside profile of the Cloaked Verge Tiles. Components Cloaked Verge Tiles are made of concrete (clay for Cathedral), in colours to match the main roof tiles.The system consists of Left-hand and Right-hand Cloaked Verge Tiles and Half Tiles (Two Thirds Tile for Cathedral). Block-end Ridge Tiles will be required for all ridge situations.

Features • Easy to lay as it interlocks to the next tile • The quickest and easiest method of installing profiled verge tiles • Provides a neat finish to the verge • Awarded British Board of Agrément Certification, certificate number 89/2189 (for concrete Cloaked Verge) • Tried and tested and complies with BS 5534 requirements for mechanical fixing • Complies with BS EN 490:2004 (concrete Cloaked Verge) and BS 8000-6:1990 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles

Performance • There is no maximum pitch on lean-to roofs or where lead roll details are used • On duo-pitch roofs above 45º the top cloaked verge tiles must be cut to a mitre • Minimum pitch will depend upon the minimum pitch for the tile profile and surface finish • Minimum headlap will depend upon tile profile and rafter pitch • Maximum headlap is 125mm (71mm for Cathedral) • Maximum pitch of cloaked verge depends upon maximum pitch of ridge/monoridge system

Compatibility • Available for all our profiled tiles except Norfolk Pantile, 49 Tile, Redland Metal Roofing and Old Hollow Pantile

74 VERGE

VERGE 75


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

AMBI-DRY VERGE SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Ambi-Dry Verge System with Overhang (Richmond)

Ambi-Dry Verge System with Vertical Slating (Cambrian)

The Ambi-Dry Verge System provides a neat, maintenance-free verge for slates and six of our popular profile tiles.With very high resistance to storm damage and with no mortar required, it removes concerns about mortar failure. Features • Secure fixing system provides high resistance to wind uplift for both verge tiles and the Ambi-Dry units • Guaranteed weathertight and secure for 15 years when used with compatible tiles and slates from the Redland range • Quick to install and can be laid at various headlaps • Can be adapted on site to fit either the left or right-hand verge • Eliminates the need for an undercloak • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification, certificate number 89/2189 • Available in terracotta, brown and grey

Components Each Ambi-Dry Verge System contains: • Ambi-Dry Verge Unit x 10 (uPVC) • Ambi-Dry Verge Clips or batten end clips x 10 (stainless steel) Each Ambi-Dry Eaves/Ridge Pack consists of: • Eaves Stop End x 1 (uPVC) + Closer Clip (stainless steel) • Ridge Comb x 1 (uPVC) + Closer Clip (stainless steel)

Compatibility and Performance Ambi-Dry Verge - Maximum Pitches

Cambrian Landmark Slate Saxon Richmond Stonewold II Mini Stonewold (inc Mockbond) Landmark Double Pantile Landmark Double Roman Grovebury 50 Double Roman Regent Renown

Duo-pitch Roofs 60º 65º 65º 65º 44º 67.5º 67.5º 62.5º 67.5º 62.5º 67.5º 60º

Mono-pitch Roofs 67.5º 50º 72.5º 72.5º 44º 72.5º 57.5º 67.5º 57.5º 67.5º 52.5º 65º

Guidance Notes • To ensure that the Ambi-Dry Verge System is located correctly, all battens for Cambrian, Landmark Slate, Richmond, Saxon and Stonewold II should oversail the bargeboard, brickwork or cladding by 50mm (60mm for other tiles) and be sawn off square (see details opposite). • For Cambrian use Standard States and Slate-and-a-halves alternately on both verges. • For all other slates use Standard Slates with interlock removed and Left-hand Half Slates alternately on left-hand verges. Use Standard Slates and Right-hand Half Slates alternately on right-hand verges. • The Ambi-Dry Verge System is not suitable for raking verges. • At the eaves, an Eaves Stop End should be used to prevent both the ingress of water and birds while providing the fixing position for the ambi-dry eaves clip. • Each Ambi-Dry Verge Unit is secured at the head by the verge/batten end clip and by lugs locating into channels on the top and bottom, along the length of the unit. It is essential that all three points of contact are engaged. • When used at a top edge abutment, or similar situation, a lead flashing should be dressed over the head of the top verge unit.The flashing length will be dependent on the rafter pitch. • At the ridge, a Ridge Comb Closer should be used to prevent the ingress of birds and a Block End Ridge tile should be used. • Where timber sarking is used over the main roof area, the tiling battens should rest on the extreme brickwork or cladding (see detail shown). Suitable for 25mm thick batten only. • Ambi-Dry Verge units for Cambrian, Stonewold II, Richmond, Saxon and Landmark Slate are fixed by Verge Clip included in the pack • Ambi-Dry Verge units for Mini Stonewold, Landmark Double Pantile, Landmark Double Roman, 50 Double Roman, Grovebury, Regent and Renown are fixed by a batten end clip included in the pack.

Ambi-Dry Verge System (Mini Stonewold)

Ambi-Dry Interlocking Verge Unit

• There is no maximum pitch on lean-to roofs or where lead roll details are used • Minimum pitch will depend upon the minimum pitch recommended for the roof tiles

Mini Stonewold Half Tile Mini Stonewold Tile with Left-hand interlock removed Spirtech 250 underlay extending over external brickwork

Brickwork built up to underside of tile batten

76 VERGE

VERGE 77


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

DRY HIP SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Dry Hip System with Third Round Hip Tile (Grovebury)

Guidance Notes • The Dry Hip System is suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions at all pitches and plan angles. • Dry hip can be adapted to ventilate the batten cavity when used with Spirtech underlay. Hip tile support must be fixed to an additional hip batten fixed over the rollable membrane. • Care must be taken when using timber sarking that the hip rafter is raised using timber batten(s) to ensure that the wood screw penetrates the hip batten by a minimum of 15mm. • All profiles require a standard 50 x 50mm hip batten, with the exception of Richmond, Saxon and Landmark Slate when this batten is reduced to 50 x 38mm. • For Cambrian slate contact Technical Solutions. • The system should start at the eaves with a Block-end Hip Tile. • For pitches up to 60º (and plan angle is 90º) where two hips intersect with a Dry or DryVent Ridge a Hip/Ridge junction should be used. • For pitches above 60º where the Dry Hip System does not finish at a conventional ridge intersection with two hips, the Hip/Ridge junction should be completed with a lead saddle. • Cambrian Double Slates will be required on all courses on either side of each hip below 25º. At pitches greater than this Cambrian Slate-and-a-halves can be used. • For number of spacer blocks and maximum centres required see fixing instructions. • For use with unequal pitches please contact Technical Solutions. • For DuoPlain use standard tiles and tile and a half adjacent to the hip to avoid small pieces of tile.

Dry Hip System with Universal Angle Hip Tile (Cambrian)

S/S Wood Screw with Neoprene Washer

The Dry Hip System has delivered years of troublefree service on tens of thousands of properties throughout the UK.With very high resistance to storm damage and no mortar required, concerns about mortar failure can be ignored. The Dry Hip System also has exceptional durability with a design life exceeding 30 years. Features • Provides a neat and attractive finish to the hip line • Hip Tiles are secured to the appropriate size hip batten using stainless steel wood screws, which give exceptional resistance to wind uplift • Quick to lay and can be used even when bad weather is expected • Awarded British Board of Agrément Certification, certificate number 89/2189 • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Compatibility • Suitable for use with the Dry and Dry Vent Ridge Systems – see page 90 • Not suitable for use with Cathedral Clay Pantile, Norfolk Pantile, 49 Tile, Rosemary, Heathland, Downland, Plain Tile, Redland Metal Roofing and Old Hollow Clay Pantile

Rollable weathertight membrane (grey)

Universal Angle Hip Universal Angle Block-end Hip

Hip Tile Support 25 x 50mm SW noggins cut between rafters and nailed with 50mm galvanised nails

Cambrian Slate cut to rake of hip

Spirtech 250 or Veltitech

Performance • Pitch range varies according to plan angle and tile profile. Please contact Technical Solutions • Minimum pitch will depend upon the minimum pitch of the roof tiles • This system is designed for use where pitches to either side of the hip are equal*

• • • • • • • • •

Components Each Dry Hip Pack contains sufficient components to secure 2.7 metres of concrete Hip Tiles. Each pack contains: Rollable weathertight membrane (grey) – 280mm x 2.75m Hip Tile Supports (Polypropylene – black) Hip Batten Straps (stainless steel) Spacer Blocks (PVC – black) Head Clips (stainless steel) Tail Clips (aluminium) 100mm Wood Screws (stainless steel) Rafter Nails (stainless steel) Hip Batten Nails (stainless steel) In addition, concrete Hip Tiles with nail holes will be required in a colour to suit, with matching Block-end Hip Tiles at the eaves. A 50 x 50mm or 50 x 38mm hip batten must be fixed.

* Where pitches are unequal, please contact Technical Solutions

234 226

305

450 31 67

Universal Angle Hip Tile

237

445

233

450

70 Third Round Hip Tile

78 HIP

Hip Tile Support

Hip/Ridge Junction

HIP 79


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

RAPID HIP SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Rapid Hip System with Third Round Hip Tile (Grovebury) S/S Hip Batten Fixing Strap nailed to hip rafter and hip batten with S/S Ring Shank Nails

S/S Woodscrew with Neoprene Washer Hip Tile Support

50 x 50mm S.W. hip batten

Rollable membrane

Third Round Hip Third Round Block-end Hip

S.W. counterbatten min. 38mm wide abutting spacer batten Grovebury Tile cut to rake of hip and mechanically fixed

Hip Batten Spacing Blocks S.W. spacer batten fixed to hip rafter to a height level with top of counterbattens Spirtech 250 underlay to overlap on adjacent slope by a min. 150mm

Aluminium Tail Clips Insulation board

Hip rafter

Rapid Hip System with Universal Angle Hip Tile (Cambrian)

Guidance Notes • The Rapid Hip System is suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions at all pitches and plan angles. Rapid Hip ventilates the batten cavity when used with Spirtech underlay. • Care must be taken when using timber sarking that the hip rafter is raised using timber batten(s) to ensure that the wood screw penetrates the hip batten by a minimum of 15mm. • All profiles require a standard 50 x 50mm hip batten, with the exception of Richmond, Saxon and Landmark Slate when this batten is reduced to 50 x 38mm for pitches up to 40º and 50 x 25mm above 40º. (Use a 50 x 38mm hip batten for Cambrian Slates above 25º). • Ensure that the tile overhang at each eaves is the same. • The system should start at the eaves with a Block-end Hip Tile. • For pitches up to 60º (and plan angle is 90º) where two hips intersect with a ridge, Hip/Ridge Junction should be used. • For pitches above 60º, plan angle other than 90º or where the Rapid Hip System does not finish at a conventional ridge intersection with two hips, the Hip/Ridge junction should be completed with a lead saddle. • Cambrian Double Slates will be required on all courses on either side of each hip below 25º. At pitches greater than this Cambrian Slate-and-a-halves can be used. • For number of spacer blocks and maximum centres required see fixing instructions. • Where pitches are unequal, please contact Technical Solutions. • For DuoPlain use tile and a half on each course either side of the hip to avoid small pieces of cut tile.

S/S Wood Screw with Neoprene Washer

The Rapid Hip System is an easy and quick-to-fit, maintenance-free hip system with very high resistance to storm damage.With no mortar required it removes concerns about mortar failure.The system also ventilates the batten cavity when used with Spirtech underlay. Features • Hips are up to a third quicker to complete than when mortar bedded. • Hip Tiles are secured to the appropriate size hip batten using stainless steel woodscrews, which give exceptional resistance to wind uplift • Provides a neat and attractive finish to the hip line • Easy to install and can be used even when bad weather is expected • Ventilates the batten cavity to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof (when used with Spirtech Vapour Permeable Underlay) • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates Compatibility • Suitable for use with the Rapid Range of Ridge Systems – see page 92 • Suitable for use with the Redland range of tiles and slates with the exception of Rosemary, Heathland, Downland, Plain Tile and Redland Metal Roofing

80 HIP

Performance • Pitch range varies according to plan angle and tile profile. Please contact Technical Solutions • Minimum pitch will depend upon the minimum pitch of the roof tiles. • This system is designed for use where pitches to either side of the hip are equal*

Rollable weathertight membrane (grey)

Universal Angle Hip Universal Angle Block-end Hip

Hip Tile Support Tray 25 x 50mm SW noggins cut between rafters and nailed with 50mm galvanised nails

Cambrian Slate cut to rake of hip and mechanically fixed

Spirtech 250 or Veltitech

• • • • • • • • •

Components Each Rapid Hip Pack contains sufficient components to secure 5 metres of concrete Hip Tiles: Rollable weathertight membrane (grey) – 280mm x 5m GRP Hip Tile Support Tray (grey) Hip Batten Straps (stainless steel) Spacer Blocks (PVC – black) Head Clips (stainless steel) Tail Clips (aluminium) 100mm Woodscrews (stainless steel) Rafter Nails (stainless steel) Hip Batten Nails (stainless steel) In addition, concrete Hip Tiles with nail holes will be required in a colour to suit, with matching Block-end Hip Tiles at the eaves. A 50 x 50mm, 50 x 38mm or 50 x 25mm hip batten must be fixed.

* Where the roof pitches are unequal, please contact Technical Solutions

235 226

305

450

67 237

2700

Universal Angle Hip Tile

233

450

70 Third Round Hip Tile

GRP Hip Tile support Tray

Hip/Ridge Junction

HIP 81


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

CAMBRIAN MITRED HIP SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Cambrian Mitred Hip System

Stainless Steel Screw and Clip

Guidance Notes • The Cambrian Mitred Hip System is suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions. • Suitable for hips with an equal pitch on both slopes. • Care must be taken when using timber sarking that the hip rafter is raised using timber batten(s) to ensure that the wood screw penetrates the hip batten by a minimum of 15mm. • Cambrian Double Slates will be required on all courses on either side of each hip below 45º pitch. At pitches of 45º and above, Cambrian Slate-anda-Halves can be used. At pitches of 45º and below use a double slate for the top course at the ridge/hip junction. • At the junction between two mitred hips and a Universal Angle duo ridge, a Cambrian Mitred Hip Block-end Ridge (product code 7211) should be used. • Where a hip starts or finishes at a position other than a duo ridge or eaves, a lead saddle will be required.

Cambrian Double Slate or Slate-and-a-half cut to rake of hip, see guidance notes

Cambrian Mitred Hip Weathering Unit

Spirtech 250 or Veltitech

Components The Cambrian Mitred Hip System contains sufficient components in each pack for ten courses of slates. Each pack contains: • Hip Weathering Units (Polypropylene – grey) • Tail Clips and Screws (stainless steel) In addition, Cambrian Double Slates or Slate-and-a-halves will be required for the mitred cuts on each side of the hip, to allow sufficient fixing at the head of the slate.

Trussed rafter

Specifically designed for use with Cambrian Slates to achieve a neat mitred hip detail, whilst ensuring very high resistance to storm damage over a wide range of rafter pitches and plan angles.

Plan Angle Against Roof Pitch Showing Approved Usage Roof Pitch (degrees)

Features • Provides a neat and attractive finish to the hip line • Easy to install and can be used even when bad weather is expected • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years with Cambrian Slates

Performance • At 90° plan angle, the minimum pitch is 15° and the maximum pitch is 80°. For other plan angles, refer to the table on the next page

Roof Plan Angle (degrees) 90 95 100 105 110

• • • • • • • • • • • • • • • • • • • • • • • • • • •

15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90

-

-

-

-

-

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

490

115

120

125

130

135

140

145

150

155

-

-

• • • • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • • • •

-

-

-

-

-

-

-

-

• • • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • •

27

• • • • • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • • • • • • •

255

• • • • • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • • • • •

• • • • • • • • • • • • •

450 300

12 140 312 Weathering Unit

82 HIP

312

600 Clip

Cambrian Mitred Hip Block-end Ridge

Cambrian Double Slate

HIP 83


SPECIFIC TION SUPPORT

CAMBRIAN GRP VALLEY

125 GRP VALLEY

Designed as a cost effective alternative to lead, the 125 GRP Valley is easy to fix, durable and lightweight. It is ideal for all types of roof design which have a junction between two roof slopes. Features • Easily cut and available in 3 metre lengths • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Fire tested to BS 476-3 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Performance • Minimum pitch 17.5° at 90° plan angle • Maximum pitch 45° at 90° plan angle • For pitch range at plan angle other than 90° please contact Technical Solutions • Width of valley gutter 125mm • Where roof plan area discharging into the valley is greater than 25m2, minimum rafter pitch is 30° • Valley can accommodate a 5° pitch variance between slopes

120

Compatibility • Suitable for all of the Redland range of tiles and slates except Cambrian Slates (for Cambrian see the Cambrian GRP Valley on the next page) and Redland Metal Roofing • A specific version of this valley is available for Natural Slate

Cement: sand mortar (to comply to tensile bond strength in BS 5534) bedding the continuous valley length onto GRP sanded strip Norfolk Pantile cut to rake of valley and mechanically fixed

125mm width between vertical faces of valley Spirtech 250 or Veltitech underlay turned up onto S.W. support batten S.W. batten supported on edge of valley support board

125 GRP Valley nailed to 25mm thick S.W valley battens

Trussed rafters 250mm x 19mm valley support board cut between trussed rafters and supported on 25mm thick noggins nailed to rafters. Top surface of support board must be flush with top of trussed rafters

84 VALLEY

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

The Cambrian GRP Valley is a cost effective, dry-fix valley which does not require any mortar in its fixing. An alternative to lead, the Cambrian GRP Valley offers a combination of exceptional ease of fixing with an extremely durable and lightweight design. Features • The only GRP Valley compatible with Cambrian Slates • Easily cut and available in 3 metre lengths • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Fire tested to BS 476-3 • Guaranteed weathertight and secure for 15 years when used with Cambrian Slates

Performance • Minimum pitch 17.5° at 90° plan angle • Maximum pitch 45° at 90° plan angle • For pitch range at plan angle other than 90° please contact Technical Solutions • Width of valley gutter 125mm • Where roof plan area discharging into the valley is greater than 25m2, minimum rafter pitch is 30° • Valley can accommodate a 5° pitch variance between roof slopes

130

400

400 Cambrian GRP Valley

125 GRP Valley

125 GRP Valley Guidance Notes • Lay the 125 GRP Valley on timber support boards, laid between rafters on noggins. • At ridge/valley intersections, a lead saddle is required. • At the eaves, cut the GRP Valley to a “V” to allow water to flow into gutters. The fascia board will require cutting to suit. • Where the valley discharges onto tiling, a lead flashing is required. • Cement: sand mortar must comply to tensile bond strength in BS5534:2003 Components • 3 metre lengths (grey glass reinforced polyester).

Cambrian GRP Valley 125mm width between vertical faces of valley Cambrian Slate-and-a-half or Double Slate cut to rake of valley S.W. batten supported on edge of valley support board

S/S Cambrian Verge Clip Cambrian GRP Valley nailed to 25mm thick S.W. valley batten

Trussed rafters Spirtech 250 or Veltitech underlay turned up face of batten

Guidance Notes • Lay the Cambrian GRP Valley on timber support boards, laid between rafters on noggins. • At ridge/valley intersections, a lead saddle is required. • At the eaves, cut the Cambrian GRP Valley to a ‘V’ to allow water to flow into gutters. The fascia board will require cutting to suit. • Where the valley discharges onto tiling, a lead flashing is required. • Cambrian Double Slates will be required on all courses on both sides of the valley below 25˚. At pitches of 25˚ and above, Cambrian Slate-anda-halves can be used. Components • Supplied in 3 metre lengths (grey glass reinforced polyester).

250mm x 19mm valley support board cut between trussed rafters and suppor ted on 25mm thick noggins nailed to rafters. Top surface of support board must be flush with top of trussed rafters

VALLEY 85


SIDE ABUTMENT GRP SECRET GUTTER

The Side Abutment GRP Secret Gutter offers a secondary line of defence against wind driven rain where a roof slope abuts a vertical wall. Being easy to cut and install makes this product an ideal solution for these otherwise complicated details. Features • Lightweight, easy to handle 3 metre lengths • Tried and tested and complies with BS 5534:2003 • Fire tested to BS 476-3 • Guaranteed weathertight and secure for 15 years when used with the Redland range of slates and DuoPlain

• For all other slates use Standard Slates with interlock removed and Left-hand Half Slates alternately on left-hand abutments. Use Standard Slates and Right-hand Half Slates alternately on right-hand abutments • Gutter Overlap: 150mm overlap for rafter pitch 30º and above. 200mm overlap for rafter pitch 22.5º - 29.5º. 250mm overlap for rafter pitch 17.5º - 22º. 300mm overlap for rafter pitch 15º - 17º. Performance • Minimum pitch 15° • Maximum pitch 90°

Compatibility • Suitable for all interlocking slates in the Redland range and DuoPlain • For Cambrian use Standard Slates and Slate-and-a-halves on alternate courses

Cavity tray Code 4 lead step and cover flashing turned into brickwork under cavity tray by a min. 25mm. Lead to dress over slate by not less than 150mm Copper clip Saxon Slate. Must be mechanically fixed 65mm min.

50mm

Spirtech 250 or Veltitech underlay turned up wall by 50mm

TOP EDGE ABUTMENT VENTILATION SYSTEM

100

25

95 Abutment GRP Secret Gutter

The Top Edge Abutment Ventilation System provides a continuous, unobtrusive, ventilation path from the roof void to the outside. The innovative design enables the system and leadwork to be installed far quicker than when traditional methods are used. Features • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates Compatibility • Available for all tiles and slates in the Redland range except Cathedral Clay Pantile, 49 Tile, Redland Metal Roofing & Old Hollow Pantile • For Natural Slate contact Technical Solutions

Performance • Minimum pitch will depend upon the minimum pitch of the roof tiles but must not be less than 15° • Maximum pitch 60° (Stonewold II 44º) • The effective ventilation area per metre run of abutment is 5,000mm2 13 5 90

10 36 10

64

15

Lead Support Tray (PVC – grey)

76

21

50 Spacer Block

17 22

10 22

64

6

Ratchet Clip (uPVC – grey)

For Profile Filler Unit and dimensions refer to p. 90 Dry Ridge System.

Abutment GRP Secret Gutter

Top Edge Abutment Ventilation System

Guidance Notes • At eaves level, a lead secret gutter outlet should be installed to allow discharge over the fascia or similar, into the eaves gutter. For a lead free alternative consider using Rapid Flashing. • Finish underlay against wall. • Finish tiling battens 55mm from wall and nail to final rafter. • Mechanically fix all slates adjacent to the abutment. • Where final rafter is less than 50mm from the wall, nail a 50 x 50mm batten to the side and flush with the top of the rafter to support ends of the tiling battens.

Guidance Notes • Ensure that the air passage from the roof void is not obstructed. • The Abutment Ventilation System is suitable for both traditional timber rafter construction, timber trussed rafter and rigid sarking constructions. • The system is designed to fit a straight and level abutment wall. • Full fixing instructions are including with each pack. • The lead-side lap should be a minimum of 150mm. (max length 1.5m) • The lead cover flashing is not supplied in the pack. Code 4 lead should be used and fitted in accordance with the Lead Sheet Association, telephone +44 (0)1622 872432. • Mechanically fix all tiles on the top course. • Use top slates as the top course for Saxon, Landmark Slate and Richmond.

Components • Supplied in 3 metre lengths (glass reinforced polyester).

Abutment GRP Secret Gutter Trussed rafter

86 ABUTMENT

ABUTMENT 87


SPECIFIC TION SUPPORT

SAFETY HOOK SYSTEM

RAPID FLASHING

Rapid Flashing can be used instead of lead on chimneys and side abutment details.The unrivalled speed and ease of installation enables standard flashing details to be completed twice as quickly as with lead, offering a viable and safer alternative to traditional methods. Features • Lighter weight than lead and easy to use • Can be moulded quickly and easily, without the need for special tools • Manufactured from environmentally-friendly materials • No welding is required, thanks to the self-fusing properties of the material • Insensitive to extremes of cold and heat (-40º to +100ºC) • UV resistant • Guaranteed weathertight and secure for 15 years when used in conjunction with the Redland range of tiles and slates

Compatibility • Compatible with all Redland tiles and slates • Not suitable for use with the Top Edge Abutment Ventilation System Performance • Suitable for all pitches and plan angles • Awarded British Board of Agrément Certification, certificate number 09/4622

Rapid Flashing Cavity tray Rapid Flashing Mini Stonewold Slate must be mechanically fixed 50 x 25mm S.W. tiling batten finished 50mm from wall

65mm min.

50mm

Abutment GRP Secret Gutter Trussed rafter

88 ABUTMENT

Veltitech or Spirtech 250 underlay turned up wall by 50mm

Guidance Notes • Must be installed on dry and clean tiles. • Rapid Flashing can be inserted into the mortar joint of brickwork as per traditional practice. • Clips must be inserted to secure Rapid Flashing to the mortar joint and then sealed with a silicone sealant. • A Side abutment secret gutter must be used with all interlocking flat tiles. Components • Supplied in 280mm and 370mm wide rolls (dark grey colourfast plastic with aluminium rib mesh insert and butyl sealing edge). • Available in: 280mm width x 5m roll length 280mm width x 10m roll length 370mm width x 5m roll length

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

The Safety Hook System combines a fall arrest anchor, ladder hook and crawling board clamp. It is designed for the attachment of roof ladders, for supporting work platforms and as a structural anchorage point for industrial safety belts and harnesses.

625 100 Safety Fixing Rail 100

Features • Roof anchor point for safety harness, offers multidirectional fall protection – eaves, verges and over ridge • Fixed support for securing roof ladders and crawling boards, offering down slope fall protection • An easy to install and cost effective solution for roof safety • Guaranteed secure and weathertight for 15 years when used with the Redland range of tiles and slates Compatibility • Suitable for cold and warm roofs with an air gap between the top of the rafters and the insulation. For warm roof construction with full-fill or above rafter insulation contact Technical Solutions • Not suitable with rigid sarking • Suitable for use with Landmark Double Pantile, Landmark Double Roman, 50 Double Roman, Grovebury, Regent, Renown and Mini Stonewold (including MockBond) Performance • Designed to accept a single static load at the anchorage point of 10kN • Suitable for rafter spacings between 350-600mm, rafter widths of 35-50mm and rafter depths of 95-200mm • Designed, manufactured and tested to BS EN 517:2006, BS EN 795 and BS 7883:2005 • Facilitates compliance with the HSE’s Health and Safety in Roof Work HSG 33 Guide, 1998

100 83

83

40

83 Outer Rafter Bracket

Inner Rafter Bracket

30

576

Safety Hook

Guidance Notes • The Roof Safety Hook must be installed in a position such that the user is afforded maximum security at all times. The choice of location must take regard of how the roof is to be accessed, free movement over the roof and securing of work platforms. • Roof Safety Hook installations should be inspected every twelve months and maintained if necessary (as set out in EN 517-B). • The following standards should also be followed when using the product: EN 355; EN 364; EN ISO 1140; EN ISO 1461.

• • • • •

Components Each Safety Hook System pack contains: 1 x Safety Hook (Hot-dipped Galvanised Steel 50mm). 1 x Safety Fixing Rail (Pre-galvanised Steel 50mm). 2 x Inner/Outer Rafter Brackets (Pre-galvanised Steel 50mm). 4 x 70mm Bolts/Nuts/Washers, 4 x 16mm A2 Bolts/Nuts/Washer. 1 x Self-adhesive Foam Strip (15 x 40 x 150mm).

SAFETY HOOK 89


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

DRY & DRYVENT RIDGE SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Guidance Notes • Dry & DryVent Ridge is suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions. The system is designed to fit a straight and level ridge line. • When used with traditional timber rafters, the height of the ridge board above the apex of the rafters (x) will alter the number of 38mm x 25mm tile battens required to construct the ridge tree.This ensures that the ridge tile securing screw achieves a minimum 15mm of penetration (see detail shown). • Where timber sarking is used with DryVent Ridge, sarking and underlay are left short of apex to allow 10mm air gap. • Counterbattens are extended to form an apex to support the ridge tree batten. • Special DryVent Ridge Packs (9085) are required when using Ornamental Universal Angle Ridge Tiles. Batten heights remain as given in the table below. • Where Gas Flue Ridge Terminals are used with DryVent Ridge, refer to Guidance Notes on page 96. • If this system is to be used with natural/fibre cement slates or unequal pitches, please contact our Technical Solutions Hotline. • Counterbattens/rafters on adjacent roof slopes must be aligned. • Detailing may vary for different profiles. Please refer to the fixing instructions. • When no high level ventilation is desired, the underlay is taken over the apex of the ridge, as in a mortar bedded detail. • Finish ridge ends with mortar or Ridge Block End tile. • Mechanically fix all tiles in the top course. • For Landmark Slate and Richmond at pitches below 25º extend and fold back the underlay to finish on the leading edge of Profile Filler Unit. • Rosemary Eave/Top Tile does not hang on the final plain tile course as for concrete plain tiles. Instead the Eave/Top Tile must be twice nailed to an additional batten that is turned on its side. Top and second top batten positions from apex are 35mm and 75mm respectively. • Use top slates on the top course for Saxon, Landmark Slate and Richmond. • A 38mm wide timber ridge batten must be fixed, the height of which will depend upon the profile of the tiles and the pitch of the roof (see table below).

DryVent Ridge System (Cambrian)

S/S Clamping Plate

S/S WoodScrew with Neoprene Washer and Foam Grommet

S.W. ridge batten 38mm wide. For height refer to table below

S/S Ridge Batten Fixing Strap fixed to each rafter with S/S Ring Shank Nails

Polypropylene Ridge to Ridge Seal

uPVC Profile Filler Unit

Universal Angle Ridge

Spirtech 250 or Veltitech underlay left short of apex to allow for ventilation

Cambrian Slate

DryVent Ridge System with Traditional Ridge Tree (Plain Tile) T imber ridge tree

Height of ridge batten taken from Ridge Batten Height Table and then reduced by dimension x to allow for the height of the ridge tree

Spirtech 250 or Veltitech

The DryVent Ridge System provides a continuous weathertight ventilation path from the roof void to the outside. The system can also be easily converted when no high level ventilation is required at the ridge. Both solutions provide an exceptionally durable method of securing ridge tiles.They are maintenancefree and require no mortar, delivering high resistance to storm damage. Features • Provides a neat and attractive finish to the ridge line • Easy to install and can be used even when bad weather is expected • Ventilates and complies with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification, certificate number 88/2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Performance • For minimum and maximum pitches, refer to the table on the next page • Must not be used below 15°

• • • •

Components for Dry & DryVent Ridge Pack Sufficient components to secure 6 Ridge Tiles, each pack contains: Profile Filler Units (uPVC – grey) Ridge to Ridge Seal (Polypropylene – black) Ridge Batten Straps (S/S) and Ring Shank Nails (S/S) 100mm woodscrews and Clamping Plates (S/S), Washer and Grommet (neoprene and foam) In addition, concrete or clay ridge tiles will be required in colour to suit, with matching Block-end Ridge Tiles at all gable ends.

Pitch Range and Ridge Batten Height for Dry & DryVent Ridge System (38mm wide ridge batten) Pitch (degrees) 12.5 15 17.5

20

22.5

25

27.5

30

32.5

35

37.5

40

42.5

45

47.5

50

52.5

55

57.5

60

62.5

65

67.5

70

Half Round Landmark Double Pantile, Grovebury - 100 100 Landmark Double Roman 75 50 Double Roman 75 Regent 100 100 100 Renown 75 Norfolk Pantile 100 Natural Slate# Cambrian 50 50 Saxon Landmark Slate, Richmond Stonewold II 75 Mini Stonewold 75 DuoPlain Plain Tile, Heathland and Downland -

75 75 75 100 75 100 50 50 50 -

75 75 75 75 50 75 50 50 50 50 -

75 75 50 75 50 75 25 25 50 50 50 50 50 -

75 50 50 75 50 75 25 25 50 50 50 50 50 -

75 50 50 75 50 75 25 25 50 50 50 50 50 -

75 50 50 75 50 75 25 25 25 25 50 50 50 -

50 50 50 75 50 75 25 25 25 25 25 25 25 50

50 50 50 50 25 50 25 25 25 25 25 25 25 25

50 50 50 50 25 50 25 25 25 25 25 25 25 25

50 25 25 50 25 50 25 25 25 25 25 25 25 25

50 25 25 50 25 50 25 25 25 25 25* 25 25 25

50 25 25 50 25 50 25 25 25 25 25 25 25

50 25 25 50 25 50 25 25 25 25 25 25 25

50 25 25 50 25 50 25 25 25 25 25 25

25 25 25 25 25

25 25

25 25

25

-

-

-

Universal Angle Natural Slate# Cambrian Saxon Landmark Slate, Richmond Stonewold II Mini Stonewold Plain Tile

-

50 -

50 75 75 -

50 75 75 -

50 50 50 75 -

25 50 50 50 50 50 -

25 25 50 50 50 50 -

25 25 50 50 50 50 -

25 25 50 50 50 50 -

25 25 25 25 25 25 50

25 25 25 25 25 25 25

25 25 25 25 25 25 25

25 25 25 25 25 25 25

25 25 25 25 25* 25 25

25 25 25 25 25

25 25 25 25

25 25 25 25

25 25 25 25

25

-

-

-

-

-

Rosemary Half Round Natural Slate# Cambrian Saxon Landmark Slate, Richmond Rosemary Clay Plain Tile

-

75 -

75 -

75 -

75 75 -

75 75 75 75 -

50 75 75 75 -

50 50 75 75 -

50 50 75 75 -

50 50 75 75 75

50 50 50 50 75

25 25 50 50 75

25 25 50 50 50

25 25 50 50 50

25 25 25 25 50

25 25 25 25 50

25 25 25 25 50

25 25 25 25 25

25 25 25 25

25 25 25

25 25 25

25 25 25

25

25

Profile 38 256

25

300 128

Half Round Ridge Tile (clay)

Batten Strap

246 51

24

21

Flat Tiles/Slates Landmark Double Pantile Landmark Double Roman Regent Grovebury 50 Double Roman Renown Norfolk Pantile

10 Ridge to Ridge Seal (Half Round concrete shown)

Profile Filler Unit (Grovebury shown)

Profile Filler Unit

58

K

J

Compatibility • Available for all tiles and slates in the Redland range except Cathedral Clay Pantile, 49 Tile, Redland Metal Roofing and Old Hollow Pantile • Suitable for use with concrete Half Round and Universal Angle Ridge Tiles and Rosemary Clay Half Round Ridge Tiles (300mm)

x see guidance notes

J

K

21 59 47 59 59 47 40 61

450 298 298 298 298 298 298 198

50 25

Clamping Plate

* 44º maximum pitch # 500 x 250 Standard Pre-holed at 190mm from head. Pitch range depends upon exposure level. Note: For Top Batten Distance from Apex please refer to the relevant product Fitting Instructions. For pitches outside the above range please contact Technical solutions. Pitches between those shown use the taller ridge batten height figure.

90 RIDGE

RIDGE 91


SPECIFIC TION SUPPORT

RAPID RIDGE & RAPID VENTED RIDGE SYSTEMS

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Rapid Ridge System (Grovebury Tile)

Guidance Notes • The Rapid Ridge and Rapid Vented Ridge Systems are suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions.The systems are designed to fit a straight and level ridge line. • When used with traditional timber rafters, the height of the ridge board above the apex of the rafters will alter the number of 38mm x 25mm tile battens required to construct the ridge tree.This ensures that the ridge tile securing screw achieves a minimum 15mm penetration. • Where timber sarking is used with Rapid Vented Ridge, sarking and underlay are left short of apex to allow 10mm air gap. Counterbattens are extended to form an apex to support the ridge tree batten. • Counterbattens/rafters on adjacent roof slopes must be aligned and extended to form an apex. • Ridge Ventilation Terminals are not suitable with Rapid Ridge or Rapid Vented Ridge Systems. • End ridges can be finished with a mortar bedded end or a Block-end Ridge Tile. • For use with unequal pitches please contact Technical Solutions. • For use with Natural Slate please contact Technical Solutions. • Mechanically fix all tiles on the top course. • Use top slates on the top course for Saxon, Landmark Slate and Richmond.

S/S Woodscrew with Neoprene Washer and Foam Grommet

S/S Clamping Plate

S.W. ridge batten 38mm wide. For height refer to table below

Polypropylene Ridge to Ridge Seal

S/S Ridge Batten Fixing Strap fixed to each rafter with S/S Ring Shank Nails

Half Round Ridge

DryRoll weathertight membrane Veltitech underlay to overlap apex by 150mm

Grovebury Tile. Must be mechanically fixed

Components for Rapid Vented Ridge Systems Each pack contains sufficient components to secure a 5 metre ridge line. 5 metres of rollable membrane. 11 ridge to ridge seals with stainless steel woodscrews and clamp plates. 9 stainless steel ridge batten straps with 18 stainless steel ring shank nails. 2 stainless steel end ridge fixings. (Not included in Rapid Vented Ridge Universal System). • Gas Flue Ridge Terminal Conversion Roll (available separately).

Rapid Vented Ridge System (Mini Stonewold)

S/S Woodscrew with Neoprene Washer and Foam Grommet S.W. ridge battens 38mm wide. For height refer to table below

S/S Clamping Plate S/S Ridge Batten Fixing Strap nailed to each rafter with S/S Ring Shank Nails Polypropylene Ridge to Ridge Seal

The Rapid Vented Ridge System is a cost effective solution for providing both high-level ventilation and mechanically fixing ridge tiles.The system is a genuine alternative to a mortar bedded ridge with the added advantage of being quicker and requiring less skill to install.The Rapid Range also includes Rapid Ridge, which is a non-ventilating dry-fix system.The illustration shows the Rapid Vented Ridge ventilating the roof void. Features • The new Rapid Vented Ridge Universal System uses a flexible Ridge-to-ridge seal to enable use with both Half Round and Universal Angle concrete ridge tiles • Traditional appearance • Up to 33% quicker to fit than a mortar bedded ridge • Easy to install and can be laid even when bad weather is expected • Rapid Vented Ridge and Rapid Vented Ridge Universal System ventilate and comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof void • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Rapid Ridge Tile Natural Slate Concrete Slate and Profile Tiles Plain Tiles* Cathedral# Old Hollow Pantile Metal Roofing Ridge Concrete Half Round Ridge* Concrete Universal Angle Ridge Clay Half Round Ridge Ridge Vent Terminal Gas Flue Ridge Terminal†

Universal Angle

Half Round

Universal Angle

Universal System

• • -

• • -

• • • -

• • • -

• • -

-

-

• •

• •

• •

Performance • For minimum and maximum pitches, refer to the table on the next page

NEW 253

58

10 Half Round Ridge Seal

92 RIDGE

253

54

12 Universal Angle Ridge Seal

51

65 Universal System Ridge Seal

• • • • • •

Rollable weathertight membrane

Rapid Vented Ridge

Half Round

# Cathedral Clay tiles are compatible with concrete Half Round Ridge tiles. * For Rosemary Clay Tiles, Downland and Heathland please contact Technical Solutions † Gas Flue Conversion Roll required

246

Spirtech 250 or Veltitech underlay left short of apex to allow ventilation

Universal Angle Ridge

Compatibility

• • • • •

Mini Stonewold Slate. Must be mechanically fixed

Components for Rapid Ridge Each pack contains sufficient components to secure a 10 metre ridge line. 10 metres of DryRoll membrane. 22 ridge to ridge seals with stainless steel woodscrews and clamp plates. 17 stainless steel ridge batten straps with 34 stainless steel ring shank nails. 2 stainless steel end ridge fixings. Gas Flue Ridge Terminal Conversion Roll (available separately).

Pitch Range and Ridge Batten Height for Rapid Ridge, Rapid Vented and Vented Universal System (38mm wide batten) Profile Half Round Landmark Double Pantile, Grovebury Landmark Double Roman 50 Double Roman Regent Renown Norfolk Pantile 49 Tile Cathedral Clay Pantile Cambrian Saxon Landmark Slate, Richmond Stonewold II Mini Stonewold Plain Tile DuoPlain Natural Slate# Universal Angle Cambrian Saxon Landmark Slate, Richmond Stonewold II Mini Stonewold Plain Tile Natural Slate#

Pitch (degrees) 12.5 15 17.5 100 -

75 75 50 -

-

50 -

20

22.5

25

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 50 50 50 75 75 75 75 50 50 50 50 75 75 50 25/50 25/50 25 50 50 50 50/75 50 50 50 50/75 50 50 50 50 25/50 50 50 50/75 50/75 75 50 -

50 50 50 50 -

50 50 50 50 50 25/50

27.5

30

32.5

35

37.5

40

75 50 50 75 50 75 50 75 25 50 50 50 50 50 25/50

75 50 50 75 50 75 50 75 25 50 50 50 50 50 25

75 50 50 75 50 75 50 75 25 50 50 25 25 50 25

50 50 50 75 50 75 50 75 25 50 50 25 25 25 50 25

50 50 50 75 50 75 50 50 25 50 50 25 25 25 25/50 25

50 50 50 50 50 75 25 50 25 25 25 25 25 25 25/50 25**

25 50 50 50 50 25/50

25 50 50 50 50 25

25 50 50 50 25 25

25 50 50 25 25 50 25

25** 25 25 25 25 25 25

25 50 50 25 25 25 25**

42.5

45

47.5

50

52.5

55

57.5

50 50 50 50 50 50 25 50 25** 25 25 25 25 25 25 25

50 50 50 50 25 50 25 50 25 25 25 25* 25 25 25 25

50 50 50 50 25 50 25 50 25 25 25 25 25 -

50 25 25 25 25 50 25** 25** 25** 25 25** -

50 25 25 25 25 25 25 25 25 25 -

50 25 25 25 25** 25 -

25 -

25 25** 25** 25 25 25 25

25 25 25 25* 25** 25 -

25 25 25 25 -

25 25 25 25 -

25 25** -

25 -

25 -

* 44° Maximum Pitch ** Maximum Pitch for Rapid Ridge (Non-Vented) Pitches between those shown use taller Ridge Batten Height For Top Batten distance from Apex please refer to the relevant product Fitting Instructions. Rapid / Rapid Vented (where different) indicated thus 50 / 75 # 500 x 250mm Standard Pre-Holed at 195mm from head. Pitch range depends upon exposure level. For pitches outside above range please contact Technical Solutions

RIDGE 93


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

RIDGE VENTILATION TERMINAL

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Half Round Ridge Ventilation Terminal (concrete) with DryVent Ridge System (Regent)

Shown for roof space ventilation

Ridge batten removed to accommodate Ridge Ventilation Terminal duct

Guidance Notes • Ridge Ventilation Terminals are suitable for timber trussed rafter and timber sarking constructions.Where traditional timber rafter construction is used, trimmers will be required for each terminal position to allow a 300mm section of the ridge board to be removed. • Where Ridge Ventilation Terminals are used in conjunction with Dry Ridge or DryVent Ridge and are required in close proximity, at least one rafter spacing will be required between each terminal to allow adequate fixing of the ridge batten after a section has been removed. • The position of the Ridge Ventilation Terminal should not be within 600mm of a gas flue such that foul gases can vent back into the building. • The Ridge Ventilation Terminal is not suitable where exhaust gases exceed 80ºC. Please use the Gas Flue Ridge Terminal (see page 96). • For soil pipe termination do not install within 3 metres horizontally and 900mm vertically of an opening e.g. roof windows and roof space ventilation. • When connected to pipework or ducting, it is recommended that where water is likely to accumulate joints are sealed and a condensation trap is fitted.

Half Round Ridge Ventilation Terminal (concrete) Terminal Adaptor Flexible Pipe. For use with soil pipes or mechanical ventilation

Regent Tile. Must be mechanically fixed

Spirtech 250 or Veltitech

Trussed rafter

Components Each Ridge Ventilation Terminal is supplied ready assembled from the following: • Terminal cap and duct (uPVC – grey) • Ridge Tile (concrete/clay – various) Where the Ridge Ventilation Terminal needs to be connected to a duct or pipe of 110mm diameter, a Terminal Adaptor and Flexible Pipe are available.

Section through Ridge Ventilation Terminal with Dry Ridge System (underlay omitted for clarity)

Terminal Adaptor

Ridge Ventilation Terminal

S.W. ridge batten

The Ridge Ventilation Terminal can be used for soil pipe, roof space ventilation or mechanical extraction. It can be incorporated into a dry or mortar bedded ridge. Features • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification, certificate numbers 89/2135 and 88/2000 • Complies with BS EN 490:2004 and BS EN 12056-2:2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Performance • Minimum and maximum pitch will depend on the tile profile and whether ridge tiles are dry fixed or mortar bedded • The effective ventilation area for each terminal is 8,400mm2 • To achieve roof space ventilation of 5,000mm2/m run, they should be spaced at 1.68m centres • The pressure/air flow resistance of the terminal is as follows: At 15 litres/sec – 6.5 Pa At 30 litres/sec – 26 Pa At 60 litres/sec – 104 Pa

Clamping Plate and Woodscrews

Ridge batten fixing straps

Flexible Pipe. For use with soil pipes or mechanical ventilation

A

Compatibility • Available in concrete Half Round and Universal Angle Ridge Tiles and Rosemary Clay Half Round Ridge Tiles • Not suitable for use with Rapid Ridge, Rapid Vented Ridge, Rapid Vented Ridge Universal System or on hip details • Cannot be used where the exhaust gas temperature may exceed 80ºC

274

V 200

W 365

100 X

Ridge Tile

U

V

W

X

98 106 128 98 98

256 255 256 256 256

450 450 450 450 450

52 34 52 52 52

Adaptor

U

228 268

38 Ridge Ventilation Terminal (Half Round shown)

Half Round Universal Angle Clay Half Round Downland Heathland

110 660

118

Pipe

94 RIDGE

RIDGE 95


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

GAS FLUE RIDGE TERMINAL

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Gas Flue Ridge Terminal with Dry Ridge System (Mini Stonewold)

Guidance notes • Gas Flue Ridge Terminals are suitable for timber trussed rafter and timber sarking constructions.Where traditional timber rafter construction is used, trimmers will be required for each terminal position to allow a 400mm section of the ridge board to be removed. • Terminals should be located in such a position in the ridge that the wind can blow freely across at all times and blockages of the flue by snow, leaves etc. are unlikely. • Care must be taken to ensure that the products of combustion cannot enter windows or air inlet grilles, or cause discomfort to any person. • Gas Flue Ridge Terminals must have a minimum 600mm of ridge tile between units. • The top batten should be placed so as to leave a minimum air gap of 25mm to the Extension Adaptor. The underlay and any timber sarking should be cut back to the line of the batten. • The ‘R’ type adaptor and Extension Adaptor must be connected to the Terminal with the nuts and washers provided. A gasket must be placed between each component to provide an effective seal. • When fitting Gas Flue Ridge Terminals, a non-vented ridge is required within 600mm on either side of the Gas Flue to comply with Building Regulations:

50mm gap from top batten to center line of ridge Gas Flue Extension Adaptor Universal Angle Gas Flue Ridge Terminal

Spirtech 250 or Veltitech underlay cut back to line of top batten

Sealing Gasket uPVC Profile Filler Unit with gas flue blanking plates

Mini Stonewold Slate. Must be mechanically fixed

‘R’ type adaptor (not supplied by Redland, can be purchased from most roofing merchants)

Gas Flue Terminal

Vented Ridge

Section through Gas Flue Ridge Terminal with Dry Ridge System (underlay omitted for clarity)

600 Ridge Batten Fixing Straps

The Gas Flue Ridge Terminal is designed for use on duo-pitched roofs in conjunction with concrete Half Round and Universal Angle Ridge Tiles on Dry-fix or bedded ridges.The Terminal is of low air-flow resistance design, to enable flue gases to escape even under high wind speed conditions. Features • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Complies with BS 5440-2:2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates Compatibility • Available in concrete Half Round and Universal Angle Ridge Tiles • Conversion Roll pack required for Rapid Ridge and Rapid Vented Ridge. Gas Flue Blanking Plates packs required for Dry & DryVent Ridge (except with Norfolk Pantile). Norfolk Pantile Gas Flue Dry Grill Fillers required for Norfolk Pantile Dry & DryVent Ridge • Not suitable for gas fired condensing boilers. For condensing boilers use a Redland Ridge Tile Outlet (not available with Heathland or Downland)

Performance • Minimum and maximum pitch will depend on the tile profile and whether ridge tiles are dry fixed or mortar bedded • The Terminal is licensed by British Gas for gas appliances of rated input not exceeding 60kW, but it is not suitable for terminating flues from traditional coal or oil burning appliances. Please check suitability with your gas coal effect fire supplier • This product is only suitable where the flue can be terminated through a 100mm or 125mm type ‘R’ adaptor (not supplied by Redland)

Gas Flue Ridge Terminal

450

600

S.W. Ridge batten 1650mm of non-vented ridge required by Gas Flue Terminal (to comply with Building Regulations)

Components Each Gas Flue Ridge Terminal is supplied ready assembled from the following components: • Ridge Tile (concrete – various colours) • Bird Screen (stainless steel) • Sealing Gasket (neoprene – black) In addition, there is an Extension Adaptor which has British Gas approval, that should be pre-assembled to the Terminal. Assembly of the ‘R’ type adaptor (not supplied by Redland) can then be achieved from within the roof space. Clamping Plate and Woodscrews

‘R’ type adaptor

A Gas Flue Ridge Terminal with Landmark Double Pantiles and Dry Vent Ridge System with Gas Flue Blanking Plates

256 450

450

355

221

9 295

20

Y

118 Ridge Tile Outlet (Half round shown)

84

200

10

295 256 Gas Flue Ridge Terminal Half Round Universal Angle

96 RIDGE

Non Vented Ridge

Y 170 167

10

330 Sealing Gasket

330 Extension Adaptor

RIDGE 97


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

DRYVENT MONORIDGE SYSTEM

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

DryVent Monoridge System (Cambrian)

uPVC Monoridge to Ridge Seal Universal Angle Monoridge

25mm board, screw fixed into trussed rafters

uPVC Profile Filler Unit Spirtech 250 or Veltitech underlay left 10mm short of apex to allow for ventilation

50mm S/S Woodscrew with Neoprene Washer

Trussed rafter

DryVent Monoridge System onto vertical tiling (Richmond)

Ensure air passage from roof void is not obstructed

The DryVent Monoridge System provides a continuous weathertight ventilation path from the roof void to the outside.The mechanically-fixed system complies with the requirements of the Building Regulations. Features • Provides a neat and attractive finish • Easy to install and can be laid even when bad weather is expected • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Performance • Minimum pitch will depend upon the minimum pitch of the roof tiles but must not be less than 15° • Maximum pitch for DuoPlain, Landmark Double Pantile, Landmark Double Roman, Grovebury, Renown and 50 Double Roman is 47.5°; maximum pitch for Landmark Slate, Richmond, Saxon and Mini Stonewold & MockBond is 52.5° (Stonewold II 44º). For all other interlocking tiles, maximum pitch is 45° • Maximum pitch for Plain Tiles is 55° • The effective ventilation area per metre run of ridge is 5,000mm2

25mm board, screw fixed into trussed rafters Richmond Slate. Must be mechanically fixed

50mm S/S Woodscrew with Neoprene Washer

Spirtech 250 or Veltitech

Guidance Notes • The DryVent Monoridge System is suitable for traditional timber rafter, timber trussed rafter and rigid sarking constructions. • The system is designed to fit a straight and level ridge line. • When used in association with vertical Plain Tiles, a lead flashing should be dressed over the top of the vertical tiling by a minimum of 150mm. • Care must be taken to ensure that the air passage from the roof void is not obstructed. Allow 10mm air gap between top tile batten and monoridge fixing batten. • Underlay is left 10mm short of apex. • Where the system forms the junction with a flat roof, the flat roof covering should lap behind the downstand leg of the monoridge. Ensure there is sufficient clearance between the downstand leg and the flat roof tilting fillet. • The system may be used with both Half Round and Universal Angle Monoridge Tiles. • When using the system with Rosemary clay plain tiles, use Landmark Monoridge Tiles. • Use Top Slates as the top course for Saxon, Landmark Slate and Richmond. • For Landmark Slate and Richmond at pitches below 25º, extend and fold back the underlay to finish on the leading edge of Profile Filler Unit. • Mechanically fix all slates on the top course. • Rosemary Eave/Top Tile does not hang on the final plain tile course. Instead the Eave/Top tile must be twice nailed to an additional batten that is turned on its side. Top and second top batten positions from apex are 10mm and 50mm respectively.

• • • • •

Components Each pack contains sufficient components to secure 6 concrete Monoridge Tiles. Each pack contains: Profile Filler Units (uPVC – grey). Monoridge, Ridge to Ridge Seal (polypropylene – black). Fixing Screws (stainless steel) and Washers (neoprene). In addition, concrete Monoridge Tiles will be required in a colour to suit, with matching Mono Block-end Ridge Tiles, left or right-hand, at all gable ends. A timber batten, 25mm thick, must be fixed vertically to allow monoridge tile fixing.

Compatibility • Available for all tiles and slates in the Redland range except Cathedral Clay Pantile, 49 Tile, Redland Metal Roofing & Old Hollow Clay Pantile • Suitable for use with concrete Half Round and Universal Angle Ridge Tiles 450

154

150

P 256

273 90 19

110

Monoridge Tile (Universal Angle shown)

98 RIDGE

Monoridge Tile

P

Half Round Universal Angle

98 106 Ridge to Ridge Seal

RIDGE 99


SPECIFIC TION SUPPORT

REDLINE VENTILATION TILES FOR INTERLOCKING TILES AND SLATES

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

RedLine Ventilation Tile connected to Flexible Pipe (Regent)

• • • • •

Polypropylene Underlay Seal lapped in with roofing underlay

Spirtech 250 or Veltitech

• • •

Regent RedLine Ventilation Tile. Must be nailed and clipped

Components • RedLine Ventilation Tiles are manufactured from UV protected, Medium Density Polyethylene and are available for most colours in our range. Redland Duoplain tile ventilation units are manufactured from PVC. For colour availability see table. • The RedLine Ventilation Tile can be used with the Flexible Pipe (9172) or Push fit Flexible Pipe (9194) for connecting to a 110mm soil vent. • Every RedLine Ventilation Tile is supplied complete with a Underlay Seal (polypropylene-black). • All RedLine Ventilation Tiles come with fixing instructions.

Flexible Pipe for use with soil vent and mechanical extraction systems

RedLine Ventilation Tile to parapet wall gutter (Mini Stonewold) RedLine Underlay Seal omitted for clarity. RedLine Ventilation Tile positioned as close as possible to top of insulation, but not on eaves course

* # †

100 VENTILATION TILES

Tilting fillet

B

A

53 Breckland Black

56 Georgian Brown †

63 Black

77 Charcoal Grey

78 Rustic Red

106

• • • • -

• • -

• -

• -

• • •

Use 30 Slate Grey RedLine Vent Use 38 Flame Red RedLine Vent Use 36 Tudor Brown

29 29 29 29 29 29 32 32 22 35

116 116 116 116 116 116 128 128 88 140

60L/sec 464 464 464 464 464 464 512 512 352 560

118 Tile Profile

- - - - - - - - - - - - • • • - • • • • - - • • • - • • • • - - - - - - - • - - - • • • • • - - - - •

- - • • • - - - - • • - • - - - - - • - - - - - • - - - - - • - - - - - - - - - - • • - - - - - - • - - - - - - • - - - - -

Landmark Double Pantile Landmark Double Roman Regent Grovebury 50 Double Roman Renown Landmark Slate Saxon/Richmond Mini Stonewold Duo Plain

Parapet wall gutter

Compatibility & Colour Table

Landmark Double Pantile Landmark Double Roman Regent Grovebury 50 Double Roman Renown Landmark Slate Richmond/Saxon Mini Stonewold DuoPlain

Air flow rate 15L/sec 30L/sec

Profile

Veltitech

52 Breckland Brown

DuoPlain • Minimum pitch 25°, Maximum pitch 90° • The effective ventilation area is 7,850mm2 • To achieve roof space ventilation of 5,000mm2/m run, Redline DuoPlain Tile Ventilation Units should be spaced at 1.57m centres • To achieve 10,000mm2 run, space at 0.78m centres

Performance • The pitch range of each RedLine Ventilation Tile will depend upon the minimum and maximum pitch of the relevant tile profile • Maximum headlap is the same as that for the relevant tile profile • The effective ventilation area for each unit is a minimum of 6,000mm2 • To achieve roof space ventilation of 5,000mm2/m run, RedLine Ventilation Tiles should be spaced at 1.2m centres • To achieve 10,000mm2/m run, space at 0.6m centres • The pressure/air flow resistance of each RedLine Ventilation Tile is shown in the table on the next page • Each RedLine Ventilation Tile is supplied complete with fixings and an underlay seal

Tuscan Red# Anthracite* Slate Grey Terracotta Tudor Brown Flame Red Farmhouse Red Rustic Brown Rich Terracotta Terracotta Brindle Brown Brindle Brecon Grey Snowdon Grey

Features • No unsightly caps • Identical interlocks to the tiles ensure a simple and weathertight installation • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification, certificate numbers 89/2135 and 88/2000 • Complies with BS EN 12056-2:2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Pressure/Air Flow Resistance (Pa)

Mini Stonewold RedLine Ventilation Tile. Must be nailed and clipped

11 13 30 34 36 38 39 40 42 43 44 47 49

The RedLine Ventilation Tile provides roof space ventilation through the leading edge of the tile ensuring that the clean lines of the roof are maintained. It is ideal for use where alternative eaves and ridge ventilation systems are not appropriate and can also be used for mechanical extraction and soil pipe ventilation.

Guidance Notes Suitable for roof space ventilation and mechanical extraction. Suitable for soil vent pipe termination for single and two storey housing. Each RedLine Ventilation Tile should be nailed and clipped. The Underlay Seal must always be installed to maintain the integrity of the roofing underlay. When using the RedLine Ventilation Tile for roof space ventilation where insulation is between the rafters, ensure the spigot pipe is clear of the insulation and cut if necessary. RedLine Ventilation Tiles are not suitable for hot flue gases, please use the Gas Flue Ridge Terminal (see page 96). RedLine Ventilation Tiles must not be laid adjacent to one another. For soil pipe termination do not install within 3 metres horizontally and 900mm vertically of an opening e.g. roof windows and roof space ventilation. When connected to pipework or ducting, it is recommended that where water is likely to accumulate joints are sealed and a condensation trap is fitted.

C

Landmark Double Pantile Landmark Double Roman Regent Grovebury 50 Double Roman Renown Landmark Slate Richmond/Saxon Mini Stonewold

A

B

C

108 114 113 108 114 110 137 137 119

172 168 180 172 168 159 170 170 149

34 31 32 34 31 31 35 35 30

385

440

RedLine Vent

20

Underlay Seal

332

330

660

118 Flexible Pipe

176

660 315 120 195 110

RedLine DuoPlain Tile Base Unit RedLine DuoPlain Tile Underlay Seal

118 Flexible Pipe

RedLine DuoPlain Tile Ventilation Adaptor

VENTILATION TILES 101


SPECIFIC TION SUPPORT

REDLINE PLAIN TILE VENTILATION UNITS

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

RedLine PlainTile Ventilation Unit (Plain Tile) • • • • • Underlay Seal RedLine Plain Tile Ventilation Unit (Secured with four nails) Veltitech

• Trussed rafter

Pressure/Air Flow Resistance (Pa)

RedLine Underlay Seal omitted for clarity

Features • Minimal visual impact • Easy to install • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification, certificate numbers 89/2135 and 88/2000 • Complies with BS EN 12056-2:2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates

Air flow rate 15 L/sec 30 L/sec

Performance • For concrete and Rosemary clay plain tiles 35° - 90° • Minimum headlap 65mm below 90°. Maximum headlap 88mm • The effective ventilation area is 6,000mm2 • To achieve roof space ventilation of 5,000mm2/m run, RedLine Plain Tile Ventilation Units should be spaced at 1.2m centres • To achieve 10,000mm2/m run, space at 0.6m centres • The pressure/air flow resistance of each RedLine Plain Tile Ventilation Unit is shown in the table on the next page

Plain Tile

Underlay Seal RedLine Plain Tile Ventilation Unit (Secured with four nails) Spirtech 250 or Veltitech

160

Vent Colour Brown Antique Red Cotswold Natural Red Slate Grey Terracotta Tudor Brown Farmhouse Red Breckland Brown Breckland Black Rustic Red

911902 911903 911912 911927 911930 911934 911936 911939 911952 911953 911978

Heathland

Autumn Sunset Ember

Autumn Autumn Autumn

911923 911923 911923

Downland

Hedgerow Brown Manor House Mix Woodland Brown

Hedgerow Brown Manor House Mix Brown

911918 911920 911902

Rosemary Clay Classic

Red Light Mixed Brindle Medium Mixed Brindle Blue Brindle Burnt Blend Copper Brindle Russet Mix Dark Antique

Red Medium Mixed Brindle Medium Mixed Brindle Blue Brindle Autumn Hedgerow Brown Hedgerow Brown Dark Antique

911980 911982 911982 911987 911923 911918 911918 911995

Rosemary Clay Craftsman

Penhurst Ashcombe

Autumn Autumn

911923 911923

274

RedLine Plain Tile Underlay Seal

RedLine Plain Tile Base Unit

660

274 118 Flexible Pipe 200

544

Brown Antique Red Cotswold Natural Red Slate Grey Terracotta Tudor Brown Farmhouse Red Breckland Brown Breckland Black Rustic Red

385

75

60 L/sec

Tile Colour

Flexible Pipe

17

136

Plain Tile RedLine Ventilation Adaptor

508

34

Redline Vent Codes

Trussed rafter

295

Compatibility • Available for all our plain tiles. For colour availability please refer to the table on the next page

Components • RedLine Plain Tile Ventilation Units are manufactured from UV protected, Medium Density Polypropylene. For colour availability see table below. • The RedLine Plain Tile Ventilation Unit can be used with Adaptor (9175) and Flexible Pipe (9172) for connecting to a 110mm soil vent pipe or mechanical ventilation duct. Each are sold separately. • Each RedLine Plain Tile Ventilation Unit is supplied with a clear PVC underlay seal. • All units are supplied with fixing instructions.

RedLine PlainTile Ventilation Unit connected to Flexible Pipe

This range of ventilators maintains the beauty of the plain tiled roof.They are ideal for roof space ventilation where alternative eaves and ridge ventilation systems are not appropriate.They can also be used for mechanical extraction and soil pipe ventilation when fitted with their adaptors.

Guidance Notes Suitable for roof space ventilation and mechanical extraction. Suitable for soil vent termination for single and two storey housing. Each RedLine Plain Tile Ventilation Unit should be secured with four nails. A RedLine Underlay Seal must always be installed to maintain the integrity of the roofing underlay. When using the RedLine Plain Tile Ventilation Unit for roof space ventilation where insulation is between the rafters, ensure the spigot pipe is clear of the insulation and cut if necessary. RedLine Plain Tile Ventilation Units are not suitable for hot flue gases, please use the Gas Flue Ridge Terminal (see page 96). For soil pipe termination do not install within 3 metres horizontally and 900mm vertically of an opening e.g. roof windows and roof space ventilation. When connected to pipework or ducting, it is recommended that where water is likely to accumulate joints are sealed and a condensation trap is fitted.

Product Code

110 RedLine Plain Tile Ventilation Adaptor

102 VENTILATION TILES

VENTILATION TILES 103


SPECIFIC TION SUPPORT GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595

THRUVENT

CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

4.5k ThruVentTile connected to Flexible Pipe (49 Tile)

49 Tile ThruVent Tile Spirtech 250 or Veltitech

Underlay Seal Flexible Pipe. For use with soil pipes and mechanical ventilation

Components • The ThruVent Tile is manufactured in concrete with a PVC ventilation unit and cap.The caps are colour co-ordinated to the colour of the tile base • The Plain Tile ThruVent consists of a three tile moulded unit, batten support brackets and clips. • Each ThruVent Tile is supplied with a Polypropylene – black Underlay Seal. • A Flexible Pipe is available for connecting to a 110mm soil vent pipe or mechanical ventilation duct.

8.8k ThruVent (50 Double Roman)

Underlay Seal omitted for clarity 50 Double Roman ThruVent Tile

Applications • Roof space ventilation, for control of condensation • Mechanical extraction ventilation terminal • Soil ventilation. Use 4.5k for low rise building (up to 2 storey). No building height restriction applies to the new 8.8k ThruVent

Roof space ventilation (mm2/m)

ThruVent spacing (m)

4.5k 4.5k 8.8k 8.8k 8.8k

5,000 10,000 5,000 10,000 25,000

0.9 0.45 1.76 0.88 0.35

Underlay Seal

Hi-Flow ThruVent Tile • Effective ventilation area of 14 - 15,000mm2 • Suitable for low level ventilation at valleys where insulation is positioned between the rafters (partial-fill). Install one Hi-Flow ThruVent tile per rafter space either side of the valley to provide effective ventilation equivalent to 25,000mm2/m

NEW

Range Slate Plain Tile

Profile

Slate

Profile

Slate

*

104 VENTILATION TILES

8.8k ThruVent (Regent)

Profile

Pressure/Air Flow Resistance (Pa) Compatible Tile Profile 15L/sec 30L/sec 60L/sec Cambrian Slate 22 88 352 Heathland 25 100 400 Downland 25 100 400 Plain Tile 25 100 400 Cathedral Clay Pantile 23 92 368 Norfolk Pantile 23 92 368 49 Tile 29 116 464 Landmark Slate 2 8 31 Saxon 2 8 31 Richmond 2 8 31 Stonewold II 3 12 49 Mini Stonewold 4 15 62 Landmark Double Pantile 2 8 32 Landmark Double Roman 2 10 38 Grovebury 2 8 32 50 Double Roman 2 10 38 Regent 2 8 34 Renown 3 12 47 Cambrian Slate 3.5 14 56 Landmark Slate 3.5 14 56 Richmond 3.5 14 56 Saxon 3.5 14 56

Effective ventilation area 4,500mm2, Downpipe diameter 75mm

**

4.5k ThruVent (Cambrian)

Guidance Notes (Hi-Flow ThruVent) • Hi-Flow ThruVent Tile installed in first full slate adjacent to valley. • Our Underlay Seal must always be installed to maintain the integrity of the roof underlay. • Each Hi-Flow ThruVent must be mechanically fixed. • Keep spigot clear of the insulation and cut if necessary. • Not suitable for hot flue gases, use the Gas Flue Ridge Terminal. • When connected to pipework or ducting, it is recommended that where water is likely to accumulate joints are sealed and a condensation trap is fitted.

S

T

4.5k ThruVentTile (A=180, B=120, C=175, D=83) Cambrian 124 60 Cathedral Clay Pantile 105 9 Norfolk Pantile 122 33 49 Tile 107 40

4.5k ThruVent*

ThruVent

Spirtech 250 or Veltitech

8.8k ThruVent**

Features • Easy to install • Ventilates to comply with BS 5250:2002, therefore reducing the risk of harmful condensation in the roof • Tried and tested and complies with BS 5534:2003 requirements for mechanical fixing • Awarded British Board of Agrément Certification certificate numbers 89/2135 and 88/2000 for 4.5k Vents • Complies with BS EN 490:2004 and BS EN 12056-2:2000 • Guaranteed weathertight and secure for 15 years when used with the Redland range of tiles and slates • Available for all tiles and slates in the Redland range except Old Hollow, DuoPlain, Redland Metal Roofing and Natural Slate

Performance • Minimum and maximum pitch will depend on the profile and surface finish • Minimum and maximum headlap will depend on the tile profile. • For Rosemary clay plain tiles, a concrete Plain Tile 4.5k ThruVent must be used. Alternatively the Redline Plain Tile Ventilation Unit can be used, refer to the previous page for colour availability • To achieve the specified roof space ventilation the ThruVents should be spaced according to the table below:

Hi-Flow***

The ThruVent Tile is a means of incorporating ventilation within the roof slope where alternative eaves and ridge ventilation systems are not appropriate. It can also be used for mechanical extraction and soil pipe ventilation. Manufactured mainly from concrete, the ThruVent Tile provides a neat, secure fit with surrounding tiles or slates.

Guidance Notes 4.5k and 8.8k (ThruVent) • The Underlay Seal provided should always be installed to maintain the integrity of the roofing underlay. • Where Plain Tile ThruVents are positioned between each rafter spacing, they should be staggered on alternate courses. • Where ThruVent Tiles are used in combination with insulation between the rafters, ensure that the pipe on the under-side is clear of the insulation, by cutting the pipe where necessary. • ThruVent Tiles are not suitable for hot flue gases, please use the Gas Flue Ridge Terminal (see page 96). • Plain Tile ThruVents are installed to 100mm gauge only. • For soil pipe termination do not install within 3 metres horizontally and 900mm vertically of an opening e.g. roof windows and roof space ventilation. • For details to install above a parapet wall gutter (see page 101). • When connected to pipework or ducting, it is recommended that where water is likely to accumulate joints are sealed and a condensation trap is fitted.

***

A

8.8k ThruVent Tile (A=303, B=202, C=200, D=109) Landmark Slate 88 24 Saxon 88 24 Richmond 88 24 Stonewold II 177 46 Mini Stonewold 114 22 Landmark Double Pantile 85 31 Landmark Double Roman 98 23 Grovebury 85 31 50 Double Roman 98 23 Regent 86 21 Renown 103 26 440

T

B

S

C

D 4.5k & 8.8k ThruVent Tile 230 165

100

385

265

100

175

20

Underlay Seal 690

118

100 165

89

32

185

Flexible Pipe for 4.5k ThruVent Tile

Effective ventilation area 8,800mm2, Downpipe diameter 100mm

For 8.8k ThruVent Flexible Pipe see page 85

4.5k Plain Tile ThruVent

Effective ventilation area 14,000mm , except Cambrian 15,000mm , No downpipe 2

2

VENTILATION TILES 105


SPECIFICATION SUPPORT

ORNAMENTAL TILES, FINIALS AND RIDGES

GUARANTEED ROOF SPECIFICATION www.redland.co.uk/specmaster or call 08708 702595 CAD DRAWINGS www.redland.co.uk/designmaster or CD-ROM available

Finials

Product Codes

Overall Size (l x w x h mm)

Height of Finial (mm)

Weight (kg)

Scroll Universal Angle Ridge

7529

300 x 259 x 306

200

8.5

Universal Angle Ridge Block-end

7530

300 x 259 x 430

200

12.8

Half Round Ridge

7527

300 x 256 x 298

200

8.1

Half Round Ridge Block-End

7528

300 x 256 x 415

200

11.6

Short Ball Top Universal Angle Ridge

7485

300 x 259 x 376

270

7.4

Universal Angle Ridge Block-end

7487

300 x 259 x 500

270

11.7

Half Round Ridge

7481

300 x 256 x 368

270

7.0

Half Round Ridge Block-end

7483

300 x 256 x 485

270

10.5

Tall Ball Top Universal Angle Ridge

7486

300 x 259 x 476

370

7.8

Universal Angle Ridge Block-end

7488

300 x 259 x 600

370

12.1

Half Round Ridge

7482

300 x 256 x 468

370

7.4

Half Round Ridge Block-end

7484

300 x 256 x 585

370

10.9

Fleur-de-Lys

Redland offers concrete finials in four designs for both Universal Angle and Half Round Ridges.These finials have been designed to replicate the most popular ornamental features found within the built environment, with the added benefit of being fully compatible with all our ridge fixing systems.

With decorative effects being incorporated more frequently into roof designs, we are the only company to offer Ornamental Plain Tiles with a guaranteed performance in all weathers down to 40 degrees pitch. Following extensive testing at our wind tunnel facility, the guarantee is offered across both concrete plain tile and Rosemary clay plain tile ranges.

Universal Angle Ridge

7491

300 x 259 x 526

420

7.8

Universal Angle Ridge Block-end

7492

300 x 259 x 650

420

12.1

Half Round Ridge

7489

300 x 256 x 518

420

7.4

Half Round Ridge Block-end

7490

300 x 256 x 635

420

10.9

Product Codes

Overall Size (l x w x h mm)

Height of Crest (mm)

Weight (kg)

Ornamental Ridge Cockscomb Ridge

Our concrete ornamental ridge fittings are compatible with mortar bedding, dry-fix and ventilated systems, enabling a complete roof, covered by our 15 Year Roof System Guarantee, to be easily achieved without compromising good looks. Guidance Notes • Fixings - all Finials and Ornamental Ridges should be fixed using 100mm stainless steel woodscrews

Universal Angle Ridge

7468

450 x 259 x 206

100

7.7

Universal Angle Ridge Block-end

7538

450 x 259 x 330

100

9.6

Half Round Ridge

7458

450 x 256 x 198

100

7.6

Half Round Ridge Block-end

7540

450 x 256 x 315

100

8.8

Three Hole Crested Ridge

A

Universal Angle Ridge

7462

450 x 259 x 256

150

8.5

Universal Angle Ridge Block-end

7558

450 x 259 x 380

150

10.4

Half Round Ridge

7455

450 x 256 x 248

150

8.4

Half Round Ridge Block-end

7560

450 x 256 x 370

150

9.6

Fleur-de-Lys Ridge

106 ORNAMENTALS

Universal Angle Ridge

7467

450 x 259 x 256

150

8.1

Universal Angle Ridge Block-end

7568

450 x 259 x 380

150

10.0

Half Round Ridge

7457

450 x 256 x 248

150

8.0

Half Round Ridge Block-end

7570

450 x 256 x 370

150

9.2

Club

Arrowhead

Bullnose

Fishtail

Available in Clay (6521) and Concrete (6251)

Available in Clay (6581) and Concrete (6451)

Available in Clay (6541)

Available in Clay (6561)

ORNAMENTALS 107


-

Half Round Monoridge Half Round Block-end Monoridge LH Half Round Block-end Monoridge RH

• • •

• • •

• • •

• • •

• • •

• • •

• • •

• • •

• • •

• • •

• • •

Universal Angle Hip Universal Angle Block-end Hip Universal Angle Mitred Hip Block-end

-

-

-

-

• • • • •

-

-

-

-

-

-

-

Universal Angle Ridge Universal Angle Block-end Ridge Universal Angle Ridge Vent Terminal Universal Angle Gas Flue Ridge Terminal Universal Angle Ridge Outlet Universal Angle Cockscomb Ridge Universal Angle Cockscomb Block-end Ridge Universal Angle 3 Hole Crested Ridge Universal Angle 3 Hole Crested Block-end Ridge Universal Angle Fleur-de-Lys Ridge Universal Angle Fleur-de-Lys Block-end Ridge Universal Angle Block-end Short Ball Top Finial Universal Angle Block-end Tall Ball Top Finial Universal Angle Block-end Scroll Finial Universal Angle Block-end Fleur-de-Lys Finial Universal Angle Short Ball Top Finial Universal Angle Tall Ball Top Finial Universal Angle Scroll Finial Universal Angle Fleur-de-Lys Finial

-

-

-

-

• • • • -

-

-

-

-

-

-

-

Universal Angle Monoridge Universal Angle Block-end Monoridge LH Universal Angle Block-end Monoridge RH

-

-

-

-

• • •

-

-

-

-

-

-

-

Hi Pitch Universal Angle Ridge Hi Pitch Universal Angle Block-end Ridge Hi Pitch Universal Angle Ridge Vent Terminal

-

-

-

-

-

-

-

-

-

-

-

-

Hi Pitch Universal Angle Monoridge Hi Pitch Universal Angle Block-end Monoridge LH Hi Pitch Universal Angle Block-end Monoridge RH

-

-

-

-

-

-

-

-

-

-

-

-

Plain Angle Ridge/Hip Bonnet Hip Arris Hip Baby Ridge Pascal Roll

-

-

• • •

-

-

• • •

-

-

-

-

-

-

-

-

Dentil Slip

• • •

• • •

-

• • •

Hogsback Ridge

-

-

-

-

Club Tile Arrowhead Tile Bullnose Tile Fishtail Tile

• •

• •

• •

-

-

-

External Angle LH 90° External Angle RH 90° Internal Angle LH 90° Internal Angle RH 90° External Angle LH 135° External Angle RH 135°

• • • • • •

• • • • • •

-

108 FITTINGS COLOUR RANGE

-

-

• • •

• • •

-

-

-

-

-

-

-

-

-

-

-

• • •

• • •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• • •

-

-

-

-

-

-

-

-

• •

• •

-

• •

-

-

• •

-

-

-

-

• • • •

• • • •

-

-

• • • •

-

-

• • • •

-

-

• • • •

-

-

-

• • •

• • •

-

• • •

• • •

-

-

• • •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• • •

-

-

• • • • •

• • • • •

-

-

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

-

-

• • • •

• • • •

-

-

-

-

-

-

• • •

• • •

-

• •

34 Terracotta

-

30 Slate Grey

Valley Trough Tile Curved Valley Tile Angular Valley Tile

-

-

-

-

-

-

-

-

-

-

• •

• •

• •

• •

• •

• •

• •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• -

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• •

-

• •

-

• •

-

-

-

-

-

• • • • • •

-

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

-

-

-

-

-

-

• • • • • •

• • • • • •

-

-

-

-

-

• • • • • •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• • •

-

-

-

-

-

-

-

-

-

-

95 Dark Antique

-

-

-

-

• • • • • •

94 Russet Mix

-

-

• • • • • •

93 Copper Brindle

-

-

91 Burnt Blend

-

-

89 Ashcombe

-

-

88 Penhurst

-

• •

-

-

-

-

-

-

-

-

-

-

• •

87 Blue Brindle

-

• • • • • • • • • • • • • • • • • • • • • • • • • •

82 Brindle

-

82 Medium Mixed Brindle

-

81 Light Mixed Brindle

-

• •

-

• • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

80 Vintage Red

-

-

-

• • • • • •

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

-

80 Red

• • • •

80 Terracotta

• • • •

79 Black

• • • •

-

-

• • • • • •

78 Rustic Red

• • • •

-

-

-

• • • • • •

77 Charcoal Grey

• • • •

64 Welsh Blue

• • • •

-

63 Highland Black/Black

• • • •

Half Round Ridge Half Round Block-end Ridge Half Round Ridge Vent Terminal Half Round Gas Flue Ridge Terminal Half Round Ridge Outlet Half Round Cockscomb Ridge Half Round Cockscomb Block-end Ridge Half Round 3 Hole Crested Ridge Half Round 3 Hole Crested Block-end Ridge Half Round Fleur-de-Lys Ridge Half Round Fleur-de-Lys Block-end Ridge Half Round Block-end Short Ball Top Finial Half Round Block-end Tall Ball Top Finial Half Round Block-end Scroll Finial Half Round Block-end Fleur-de-Lys Finial Half Round Short Ball Top Finial Half Round Tall Ball Top Finial Half Round Scroll Finial Half Round Fleur-de-Lys Finial

-

60 Vintage Blue

57 Slate Blue

-

53 Breckland Black

25 Ember

-

52 Breckland Brown

24 Sunset

-

49 Snowdon Grey

23 Autumn

-

47 Brecon Grey

21 Woodland Brown

-

44 Brown Brindle

20 Manor House Mix

-

43 Terracotta Brindle

18 Hedgerow Brown

• • • • • •

42 Rich Terracotta

13 Anthracite

• • • • • •

40 Rustic Brown

12 Cotswold

• • • • • •

39 Farmhouse Red

11 Red

• • • • • •

36 Tudor Brown

03 Antique Red

• • • • • •

Third Round Hip Third Round Block-end Hip

27 Natural Red

02 Brown

FITTINGS COLOUR RANGE

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• • •

• • •

• • •

• •

• •

• • •

• • •

• • •

• • •

-

-

-

-

-

-

-

• • •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• •

• •

-

• •

• -

• -

• •

• •

• •

• •

-

• •

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

• • • • • • • • •

-

• • • • • • • • •

• • • • • • • • •

-

• • • • • • • •

• • • • • • •

• • • • • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • •

-

-

-

-

-

-

-

-

-

-

-

-

FITTINGS COLOUR RANGE 109


Mini Stonewold/ MockBond Mini Stonewold

Stonewold II

Richmond

Landmark Slate

Saxon

Cambrian

Natural Slate

Mini Stonewold/ MockBond Mini Stonewold

Stonewold II

Richmond

Landmark Slate

Saxon

For fittings colour range availability refer to table on page 108-109.

Cambrian

Product codes are given with dimensions below in small text. All dimensions are in mm (unless stated) in the order: length, width and height (where applicable).

Natural Slate

PRODUCT CODES – SLATE RANGE

)

Slates Standard Slate (shown above) Cambrian Slate-and-a-half

For sizes see page 21 –

Hip Systems (continued) 4701

4951

4601

4851

4161

4261/4271

300 x 336

412 x 334

412 x 334

412 x 334

430 x 380

418 x 334

4702

7779

7779

7779

8327

7779

7779

7779

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

7784

7784

7784

8317

7784

7784

7784

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

Cambrian GRP Valley 125 GRP Valleys Natural Slate GRP Valley

– – 9413

9553 – –

– 9595 –

– 9595 –

– 9595 –

– 9595 –

– 9595 –

Top Edge Abutment Ventilation System

9548

9548

9548

9548

9548

9548

9548

9955/9956 9957

9955/9956 9957

9955/9956 9957

9955/9956 9957

9955/9956 9957/9

9955/9956 9957/9958

9955/9956 9957/9958

Abutment GRP Secret Gutter

9596

9596

9596

9596

9596

9596

9596

Dry & DryVent Ridge System – Universal Angle Dry & DryVent Ridge System – Half Round Dry & DryVent Ridge System – Rosemary Half Round

9059 9058 9056

9059 9058 9056

9059 9058 9056

9059 9058 9056

9059 9058 9056

9059 9058 9056

9059 9058 9056

Rapid Ridge System – Universal Angle Rapid Ridge System – Half Round Rapid Vented Ridge – Universal Angle Rapid Vented Ridge – Half Round Rapid Vented Ridge – Universal System Rapid Ridge Gas Flue Conversion Roll

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

9306 9303 9308 9302 9311 9486

7254

7254

7254

8330

7254

7254

7254

Universal Angle Block-end Hip Third Round Block-end Hip

300 x 486

Valley Systems Cambrian Left-hand Verge Slate

4703

300 x 300

Cambrian Left-hand Verge Slate-and-a-half

4704

Abutment Systems

300 x 450

Cambrian Double Slate

4705 300 x 636

Half Slate Pair

(left-hand) (right-hand)

R/H

Rapid Flashing (5m/10m x 280mm) Rapid Flashing (5m x 370mm) 4954

4604

4854

4164

4263

412 x 150 412 x 182

412 x 150 412 x 184

412 x 150 412 x 182

430 x 172 430 x 208

418 x 147 418 x 187

L/H

Top Slate

Eaves Slate

Underlays

Spirtech 250 vapour permeable underlay Veltitech non-breathable underlay

Eaves Systems

RedVent Eaves Ventilation System 350-450mm RedVent Eaves Ventilation System 450-600mm Extension Trays 350-450mm Extension Trays 450-600mm

4955

4605

4855

412 x 334

412 x 334

412 x 334

4964

4614

4864

412 x 334

412 x 334

412 x 334

9077

9077

9077

9077

9077

9077

9077

50m x 1.5m

50m x 1.5m

50m x 1.5m

50m x 1.5m

50m x 1 5m

50m x 1.5m

50m x 1.5m

9072

9072

9072

9072

9072

9072

9072

30m x 1.5m

30m x 1.5m

30m x 1.5m

30m x 1.5m

30m x 1 5m

30m x 1.5m

30m x 1.5m

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

RedVent 25 Over-Fascia Vent Underlay Support Tray

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

Ambi-Dry Verge System Ambi-Dry Eaves/Ridge System Continous Dry Verge

– – 9412

9570 9491 –

9573 9487 –

9573 9487 –

9573 9487 –

9576 9495 –

9550 9552 –

Cambrian Mitred Hip System

9504

Ridge Systems

Ridge Ventilation Terminal – Universal Angle

450 x 259 x 140 450 x 259 x 140

Ridge Ventilation Terminal – Hi–Pitch Universal Angle

Hip Systems

Dry Hip System Rapid Hip Universal Angle Hip/Ridge Junction

9048 9503 9520

9048 9503 9520

9047 9524 9520

9047 9524 9520

9047 9524 9520

9046 9028 9520

9046 9028 9520

7253

7255 7253

450 x 256 x 150 450 x 256 x 150

Ridge Ventilation Terminal – Rosemary Half Round

8486

8486

450 x 256 x 180 450 x 256 x 180

Ridge Ventilation Terminal Adaptor Flexible Pipe (100 to 100) Gas Flue Ridge Terminal – Universal Angle

Verge Systems

7255

678 x 255 x 187 678 x 255 x 187

Ridge Ventilation Terminal – Half Round

9175 9172

9175 9172

7242

7242

450 x 259 x 172 450 x 259 x 172

Gas Flue Ridge Terminal – Half Round

7241

7241

450 x 256 x 176 450 x 256 x 176

Third Round Hip without nail holes Third Round Hip with nail holes Hip Iron

110 PRODUCT CODES

7777 7778

7777 7778

8322 8321

7777 7778

7777 7778

7777 7778

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

450 x 226 x 75

8122 7411

8122 7411

8122 7411

8312 8311

8122 7411

8122 7411

8122 7411

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

450 x 233 x 70

9258

9258

9258

9258

9258

9258

9258

7253

450 x 256 x 150 450 x 256 x 150

8486

8486

450 x 256 x 180 450 x 256 x 180

9175 9172

9175 9172

7242

8329

450 x 259 x 172 450 x 259 x 172

7241

7255

678 x 255 x 187

8310

8309

450 x 256 x 176 450 x 256 x 176

7253

7255 678 x 255 x 187

7253

7253

450 x 256 x 150 450 x 256 x 150 450 x 256 x 150

8486

8486

8486

450 x 256 x 180 450 x 256 x 180 450 x 256 x 180

9175 9172

9175 9172

9175 9172

7242

7242

7242

450 x 259 x 172 450 x 259 x 172 450 x 259 x 172

7241

7241

7241

450 x 256 x 176 450 x 256 x 176 450 x 256 x 176

9143 9099

9143 9099

9143 9099

9143 9099

9143 9099

9143 9099

9143 9099

Ridge Tile Outlet – Universal Angle

8192

8192

8192

8192

8192

8192

Ridge Tile Outlet – Half Round

8191

8191

8191

8191

8191

8191

Universal Angle Ridge

7146

7146

7146

8319

7146

7146

450 x 259 x 106 450 x 259 x 106

Hi–Pitch Universal Angle Ridge

7151

7151

335 x 255 x 153 335 x 255 x 153

Half Round Ridge

Universal Angle Block-end Ridge

Half Round Block-end Ridge Rosemary Half Round Block-end Ridge

7151

335 x 255 x 153

7146

450 x 259 x 106 450 x 259 x 106 450 x 259 x 106

7151

335 x 255 x 153

7151 335 x 255 x 153

8101

8101

8101

8302

8101

8101

8101

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

8450

8450

8450

8450

8450

8450

8450

7518

7518

450 x 259 x 106 450 x 259 x 106

Hi–Pitch Universal Angle Block-end Ridge

450 x 259 x 106 450 x 259 x 106

450 x 256 x 98

300 x 256 x 128 300 x 256 x 128

7777 7778

7255 678 x 255 x 187

450 x 259 x 140 450 x 259 x 140 450 x 259 x 140

Gas Flue Ridge Terminal Extension Adaptor Gas Flue Blanking Plates

Rosemary Half Round Ridge

Universal Angle Hip without nail holes Universal Angle Hip with nail holes

450 x 259 x 140 450 x 259 x 140

300 x 256 x 128 300 x 256 x 128

7518

8320

450 x 259 x 106 450 x 259 x 106

7518

7518

7518

450 x 259 x 106 450 x 259 x 106 450 x 259 x 106

7401

7401

7401

365 x 255 x153

365 x 255 x153

365 x 255 x153

7519

7519

7519

8303

7519

7519

7519

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

450 x 256 x 98

8456

8456

8456

8456

8456

8456

8456

300 x 256 x 128 300 x 256 x 128

300 x 256 x 128 300 x 256 x 128 300 x 256 x 128

7401

365 x 255 x153

300 x 256 x 128 300 x 256 x 128

7401 365 x 255 x153

300 x 256 x 128 300 x 256 x 128 300 x 256 x 128

PRODUCT CODES 111


DryVent Monoridge System – Universal Angle DryVent Monoridge System – Half Round

Universal Angle Monoridge

450 x 154 x 273 450 x 154 x 273

7148

7148

Hi-Pitch Universal Angle Monoridge

7154

7154

335 x 154 x 320 335 x 154 x 320

Half Round Monoridge

7203

7203

450 x 154 x 273 450 x 154 x 273

Universal Angle Block-end Monoridge Left-hand Universal Angle Block-end Monoridge Right-hand

7297 7298

7297 7298

450 x 154 x 273 450 x 154 x 273

Hi-Pitch Universal Angle Block-end Monoridge Left-hand Hi-Pitch Universal Angle Block-end Monoridge Right-hand

7785 7786

7785 7786

365 x 154 x 320 365 x 154 x 320

Half Round Block-end Monoridge Left–hand Half Round Block-end Monoridge Right–hand

7266 7267

7266 7267

450 x 154 x 273 450 x 154 x 273

Ventilation Tiles

7148

8324

450 x 154 x 273 450 x 154 x 273

7154

335 x 154 x 320

7203

8304

7297 7298

8325 8326

450 x 154 x 273 450 x 154 x 273

7785 7786

– –

365 x 154 x 320

7266 7267

7154

7203

8305 8306

Eaves/Top Tile

7154 335 x 154 x 320

7203

Rosemary Red Rosemary Russet Mix Rosemary Light, Medium Mixed & Blue Brindle Rosemary Burnt Blend/Copper Brindle/Dark Antique

7203

450 x 154 x 273 450 x 154 x 273 450 x 154 x 273

7297 7298

7297 7298

7297 7298

7785 7786

– –

7266 7267

7785 7786 365 x 154 x 320

7266 7267

7266 7267

450 x 154 x 273 450 x 154 x 273 450 x 154 x 273

6921

As per colour

6661

6651

6151

6101

265 x 165

265 x 165

265 x 165

265 x 165

268 x 165

268 x 330

– – – –

6501 6701 6801 6601

– – – –

– – – –

– – – –

– – – – – – – – – –

6924

As per colour

6664

6654

6154

200 x 165

215 x 165

215 x 164

200 x 165

200 x 165

– – – –

6504 6704 6804 6604

– – – –

– – – –

– – – –

6929

As per colour

6669

6659

6159

6102

265 x 248

265 x 248

265 x 246

265 x 248

268 x 248

268 x 480

Rosemary Red Rosemary Russet Mix Rosemary Light, Medium Mixed & Blue Brindle Rosemary Burnt Blend/Copper Brindle/Dark Antique

– – – –

6509 6709 6809 6609

– – – –

– – – –

– – – –

– – – –

Left-hand Verge (Three Quarter) Tile

Right-hand Verge (Three Quarter) Tile

Tile-and-a-half

450 x 154 x 273 450 x 154 x 273 450 x 154 x 273

365 x 154 x 320

450 x 154 x 273 450 x 154 x 273

Rosemary Red Rosemary Russet Mix Rosemary Light, Medium Mixed & Blue Brindle Rosemary Burnt Blend/Copper Brindle/Dark Antique

450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 335 x 154 x 320

450 x 154 x 273 450 x 154 x 273

Standard Tile (shown above)

DuoPlain Tile

7148

Tiles

Plain Tile

9084 9084

Downland

9084 9084

Heathland

9084 9084

9084 9084

Rosemar y Classic

9084 9084

Ridge Systems (continued)

Rosemar y Craftsman

Mini Stonewold/ MockBond Mini Stonewold

7148

Stonewold II

7148

Richmond

9084 9084

PLAIN TILE RANGE

Landmark Slate

9084 9084

Saxon

For fittings colour range availability refer to table on page 108-109.

Cambrian

Product codes are given with dimensions below in small text. All dimensions are in mm (unless stated) in the order: length, width and height (where applicable).

Natural Slate

PRODUCT CODES – SLATE RANGE

6103 268 x 222

RedLine Ventilation Tile with Underlay Seal RedLine Ventilation Flexible Pipe

– –

– –

9120 9194

9120 9194

9120 9194

– –

9118 9194

Underlays

9077

9077

9077

9077

9077

9077

50m x 1.5m

50m x 1.5m

50m x 1.5m

50m x 1.5m

50m x 1.5m

50m x 1.5m

9072

9072

9072

9072

9072

9072

30m x 1.5m

30m x 1.5m

30m x 1.5m

30m x 1.5m

30m x 1.5m

30m x 1.5m

RedVent Eaves Ventilation System 350-450mm RedVent Eaves Ventilation System 450-600mm Extension Tray 350-450mm Extension Tray 450-600mm

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

RedVent 25 Over-Fascia Vent Underlay Support Tray

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

– –

– –

– –

– –

– –

9534 9562

Spirtech 250 Veltitech

Natural Slate Standard Vent Tile 4.5k ThruVent Tile with Underlay Seal Flexible Pipe (75 to 100) 8.8k ThruVent Tile with Underlay Seal Flexible Pipe (100 to 100)

9414 – 9188 – –

– 7705 9188 – –

– – – 7937 9172

– – – 7940 9172

– – – 7936 9172

– – – 7934 9172

– – – 7935 9172

Natural Slate Hi-Capacity Vent Tile Hi-Flow ThruVent Tile with Underlay Seal

9416 –

– 7349

– 7361

– 8336

– 7360

– –

– –

9332

9332

9332

9417

50 x 3

50 x 3

50 x 3

9192 (inc nails) –

9296 9332

9296 9332

9296 9332

9296 9332

9527 9332

50 x 3

50 x 3

50 x 3

50 x 3

50 x 3

9299

9299

9299

9240

9530 (inc nails)

6104 268 x 255

Eaves Systems

Fixing Slate Nails (Alum. Alloy) Natural Slate Nails (Copper)

9338

Hip Systems

50 x 3.35

30 x 3

Natural Slate Nails (Copper)

9418 38 x 3

Eaves Clip Eaves Clip Nails (Alum. Alloy)

Slate Clip

– –

9196 (inc nails)

Dry Hip System Rapid Hip System Bonnet Hips

35˚ - 42.5˚ 43˚ - 60˚ 35˚ - 50˚

8428 8429 –

8428 8429 –

– – 7671

– – 7602

– – 8125

– – –

Arris Hips

35˚ 40˚ 45˚ 50˚ 35˚ - 42˚ 42.5˚ - 50˚

– – – – – –

8411 8412 8413 8414 – –

– – – – – –

– – – – – –

– – – – 7128 7127

– – – – – –

8454/NA

Third Round Hips (without/with nail holes)

300 x 233 x 70

Verge Clip

9193 (inc nails)

9481

9481

9481

9297

9529

25 x 2.65 Clout

25 x 2.65 Clout

25 x 2.65 Clout

25 x 2.65 Clout

25 x 2.65 Clout

9258 –

Hip Iron Third Round Hip Block-end Baby Ridge*

Double Battening Clip (Alum. Alloy)

9204

40 x 2.65

9447 9567 9566 9584

9447 9567 9566 9584

9447 9567 9566 9584

9447 9567 9566 9584

9447 9567 9566 9584

9447 9567 9566 9584

9447 9567 9566 9584

9889

Safety Systems Safety Hook

112 PRODUCT CODES

9258 –

9258 –

8212/8211 450 x 233 x 70

9258 –

9258 7404

8482

8482

7675

7606

7107

7408

300 x 140 x 70

300 x 140 x 70

300 x 140 x 70

300 x 140 x 70

300 x 140 x 70

300 x 140 x 70

7126

300 x 150 x 70

Valley Systems

Bedded Hip and Ridge Mechanical Fixing Stainless Steel Batten Straps Universal Angle Clamping Plates Half Round Clamping Plates Woodscrews (100 x 4),Washers & Grommets

Pascal Roll*

9258 –

8122/7411 450 x 233 x 70

Curved Valley Tiles

40˚ - 50˚ 35˚ - 50˚

8432 –

8432 –

– 7672

– 7603

– 8133

– –

Angular Valley Tiles

35˚ 40˚ - 50˚

8431 8437

– –

– –

– –

– –

– –

9595

9595

9595

9595

9595

9595

GRP 125 Valley * Not suitable for main roof areas (should be used on porches/bay windows only)

PRODUCT CODES 113


DuoPlain Tile

9548

Plain Tile

9548

Downland

9548

Heathland

DuoPlain Tile

9548

9119 9175 9172

9119 9175 9172

9119 9175 9172

9119 9175 9172

9119 9175 9172

9113 – 9172

4.5k ThruVent Tile with Underlay Seal (concrete)

7677

7620

7347

ThruVent Flexible Pipe (75 to 100)

9188

9188

9188

8441/8440

8441/8440

7673/7674

7604/7605

8134/8135

165 x 83

165 x 83

165 x 83

165 x 83

165 x 83

8443/8442

8443/8442

7680/7681

7623/7624

7136/7137

164 x 92

164 x 92

164 x 92

164 x 92

164 x 92

7684/7685

7627/7628

7142/7143

168 x 92

168 x 92

168 x 92

Rosemar y Classic

Plain Tile

9548

Abutment Systems

Rosemar y Craftsman

Downland

9548

Rosemar y Classic

For fittings colour range availability refer to table on page 108-109.

Rosemar y Craftsman

Product codes are given with dimensions below in small text. All dimensions are in mm (unless stated) in the order: length, width and height (where applicable).

Heathland

PRODUCT CODES – PLAIN TILE RANGE

Ventilation Tiles Top Edge Abutment Ventilation System

9955/9956

9955/9956

9955/9956

9955/9956

9955/9956

9955/9956

Rapid Flashing (5m x 370mm)

9957

9957

9957

9957

9957

9957

Abutment GRP Secret Gutter

9596

Rapid Flashing (5m/10m x 280mm)

RedLine Plain Tile Ventilation Unit with Underlay Seal RedLine Ventilation Adaptor Flexible Pipe (100 to 100)

Ridge Systems Dry & DryVent Ridge System – Half Round

9056

9056

9057

9057

9058

9058

Internal and External Vertical Angles External Angle 90° (left/right-hand) Rapid Ridge System – Half Round Rapid Vented Ridge – Half Round Rapid Vented Ridge – Universal System

Ridge Ventilation Terminal – Half Round Ridge Ventilation Terminal Adaptor Flexible Pipe (100 to 100)

– – –

– – –

– – –

– – –

9303 9302 9311

9303 9302 9311

8486

8486

7678

7621

7253

7402

450 x 256 x 180

450 x 256 x 180

450 x 256 x 150

450 x 256 x 150

450 x 256 x 150

450 x 256 x 150

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

7679

7622

7241

7410

450 x 256 x 176

450 x 256 x 176

450 x 256 x 176

450 x 256 x 176

Internal Angle 90° (left/right-hand)

External Angle 135° (left/right-hand)

Fixing Gas Flue Ridge Terminal – Half Round Gas Flue Ridge Terminals Extension Adaptor Gas Flue Blanking Plates Rapid Range Gas Flue Conversion Roll

Ridge Tile Outlet – Half Round

Hogsback Ridge

Plain Angle Ridge

– – –

90˚

85˚

– – –

9143 9099 –

9143 9099 –

9143 9099 9486

9143 9099 9486

9331

9331

9331

9331

9331

40 x 2.65

40 x 2.65

40 x 2.65

40 x 2.65

40 x 2.65

Tile Nail (Alum. Alloy)

9334

Eaves Screw (Stainless Steel)

9104

Top Tile Clip

9282

9282

9282

Tile Nail (Alum. Alloy)

– 45 x 3 40 x 4.17

8191

7405

Tile-to-Tile Clip

9197

7102

Universal Verge Clip (left/right-hand)

9198

9447 9566 9584

9447 9566 9584

9447 9566 9584

9447 9566 9584

9447 9566 9584

9447 9566 9584

8480

8480

300 x 292 x 119

300 x 292 x 119

450 x 286 x 178

120˚

7105

450 x 286 x 103

140˚

7106

450 x 286 x 71

Half Round Ridge

Half Round Block-end Ridge

8450

8450

7670

7601

8101

8201

300 x 256 x 128

300 x 256 x 128

300 x 256 x 98

300 x 256 x 98

450 x 256 x 98

450 x 256 x 98

DryVent Monoridge System – Half Round

Half Round Monoridge

Half Round Block-end Monoridge (left/right-hand)

114 PRODUCT CODES

7691

7663

7519

7409

300 x 256 x 98

300 x 256 x 98

450 x 256 x 98

450 x 256 x 98

9084

9084

9084

9084

7683

7625

7203

7403

450 x 154 x 273

450 x 154 x 273

450 x 154 x 273

450 x 154 x 273

7266/7267

7266/7267

7266/7267

7406/7407

Bedded Hip and Ridge Mechanical Fixing Stainless Steel Batten Straps Half Round Clamping Plates Woodscrew (100 x 4),Washers & Grommets

PRODUCT CODES 115


Underlays

2201

3401

1501

5101

1101

418 x 330

418 x 332

418 x 330

381 x 227

382 x 226

9077

9077

9077

9077

9077

9077

9077

9077

9077

9077

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

50m x 1 5m

7241

7241

7241

7241

49 Tile

8309

50 Double Roman

8309

Norfolk Pantile

5741 418 x 332

Renown

5201 418 x 330

Regent

5901 418 x 332

Grovebur y

5921 409 x 264

Cathedral Clay Pantile

Old Hollow Clay Pantile

49 Tile

Norfolk Pantile

Renown

Regent

50 Double Roman

Grovebur y

Landmark Double Roman

5991 343 x 242

Landmark Double Roman

Standard Tile (shown above)

Landmark Double Pantile

Tiles

Landmark Double Pantile

For fittings colour range availability refer to table on page 108-109.

Cathedral Clay Pantile

Product codes are given with dimensions below in small text. All dimensions are in mm (unless stated) in the order: length, width and height (where applicable).

Old Hollow Clay Pantile

PRODUCT CODES – PROFILE RANGE

Ridge Systems (continued) Gas Flue Ridge Terminals – Half Round

Gas Flue Ridge Terminals Extension Adaptor

8309 9143

9143

9143

9143

7241 9143

9143

9143

9143

7241 9143

Gas Flue Blanking Plates

9098

9098

9098

9098

9098

9098

9089

Ridge Tile Outlet – Half Round

8191

8191

8191

8191

8191

8191

8302

8302

8302

8101

8101

8101

8101

8101

8101

450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176 450 x 256 x 176

Spirtech 250 vapour permeable underlay

9072

9072

9072

9072

9072

9072

9072

9072

9072

9072

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

30m x 1 5m

RedVent Eaves Ventilation System 350-450mm RedVent Eaves Ventilation System 450-600mm Extension Trays 350-450mm Extension Trays 450-600mm

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

9189 9190 9498 9499

Half Round Ridge

RedVent 25 Over-Fascia Vent Underlay Support Tray

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

9593 9076

Veltitech non-breathable underlay

Eaves Systems

450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98

7835#

7831#

Half Round Block-end Ridge

8303

8303#

8303

7519

7519

7519

7519

7519

7519

Capped Half Round Block-end Ridge

7832/7833#

DryVent Monoridge System – Half Round

9080

9082

9080

9082

9079

09081

0083

Half Round Monoridge

8304•

8304

8304

7203

7203

7203

7203

7203

7203

Capped Half Round Ridge

450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98 450 x 256 x 98

Verge Systems Cloaked Verge System

5927/5928# 8333/8334 8343/8344 7273/7274 7275/7276 7271/7272 100 7277/7278

(left/right-hand)

Left-hand Verge Tile

5992#

5926#

5929#

450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273

Half Tile/Two-Thirds Tile

8331

418 x 182

7770

7730

7750

7710

418 x 182

418 x 180

418 x 182

418 x 180

Ambi-Dry Verge System

9550

9550

9550

9550

9550

9550

Ambi-Dry Eaves/Ridge Pack

9552

9552

9552

9552

9552

9552

Dry Hip System Rapid Hip System Third Round Hip/Ridge Junction

– – –

– 9870 9521

9046 9028 9521

9046 9028 9521

9046 9028 9521

9046 9028 9521

9046 9028 9521

9046 9028 9521

– 9502 9521

– 9502 9521

Half Round Block-end Monoridge

Hip Systems

8305/8306• 8305/8306 8305/8306 7266/7267 7266/7267 7266/7267 7266/7267 7266/7267 7266/7267 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273 450 x 154 x 273

7172

7172

7173

7172

7173

7172

7174

7172

RedLine Ventilation Tile with Underlay Seal

9114

9117

9114

9117

9115

9116

RedLine Ventilation Flexible Pipe (100 to 100)

9194

9194

9194

9194

9194

9194

7834 9188 – –

7830 9188 – –

– – 7938 9172

– – 7939 9172

– – 7931 9172

– – 7933 9172

– – 7930 9172

– – 7932 9172

7329 9188 – –

7334 9188 – –

Dentil Slip

Third Round Hip (without/with nail holes)

(left/right-hand)

Ventilation Tiles

8312/8311• 8312/8311 8312/8311 8122/7411 8122/7411 8122/7411 8122/7411 8122/7411 8122/7411 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70

Hip Iron Third Round Block-end Hip

9258

9258

9258

9258

9258

9258

9258

9258

9258

9258

8317•

8317

8317

7784

7784

7784

7784

7784

7784

4.5k ThruVent Tile with Underlay Seal Flexible Pipe (75 to 100) 8.8k ThruVent Tile with Underlay Seal Flexible Pipe (100 to 100)

450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70 450 x 233 x 70

Valley Systems 125 GRP Valley

9595

9595

9595

9595

9595

9595

9595

9595

9595

9595

Fixing Tile Nails (Alum. Alloy) Top Edge Abutment Ventilation System

Rapid Flashing (5m/10m x 280mm) Rapid Flashing (5m x 370mm)

9541

9543

9541

9543

9542

9544

9545

Ridge Systems Dry & DryVent Ridge System – Half Round

9094

9095

9094

9095

9096

9097

9055

9178 9332

9178 9332

50 x 3

50 x 3

Reform Eaves Filler Unit Eaves Comb Filler

– 9965

– 9965

Tile Clip

9637

9636

Tile Clip Nail (Alum. Alloy)

9634

60 x 2.65

Eaves Clip Eaves Clip Nails (Alum. Alloy)

9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9955/9956 9957 9957 9957 9957 9957 9957 9957 9957 9957 9957

9638 55 x 2 65

Abutment Systems

Verge Clip (left/right-hand)

9336 70 x 3 75

9333

60 x 3.35

9336

9333

9337

9332

9334

9332

70 x 3 75

60 x 3 35

75 x 3 75

50 x 3

45 x 3

50 x 3

9186 9332

9178 9332

9527 9332

50 x 3

50 x 3

50 x 3

– –

9207 –

– –

9287(inc nails) 9287(inc na ls) 9287(inc na ls) 9287(inc nails) 9287(inc na ls) – – – – – 9216 – 9246

– – 9288

9216 –

– –

9246

9288

9217 – 9246

9185

9177

9185

9333

9333

9333

9333

9333

9333

9333

9333

60 x 3 35

60 x 3 35

60 x 3 35

60 x 3 35

60 x 3 35

60 x 3 35

60 x 3 35

60x3 35

9639/9640 9632/9633 9121/9298 9297/9121 9121/9298 9297/9121 9121/9298 9297/9297 9148/9149 9297/9297 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout 25 x 2 65 Clout

Rapid Ridge System – Half Round Rapid Vented Ridge System – Half Round Rapid Vented Ridge – Universal System Rapid Range Gas Flue Conversion Roll Ridge Ventilation Terminal – Half Round

– – – – –

– 9304 – 9486 8310•

9303 9304 9311 9486 8310

9303 9304 9311 9486 8310

9303 9304 9311 9486 7253

9303 9304 9311 9486 7253

9303 9304 9311 9486 7253

9303 9304 9311 9486 7253

9303 9304 9311 9486 7253

9303 9304 9311 9486

Bedded Hip and Ridge Mechanical Fixing

7253

Stainless Steel Batten Straps

9447

9447

9447

9447

9447

9447

9447

9447

9447

Half Round Clamping Plates

9566

9566

9566

9566

9566

9566

9566

9566

9566

Woodscrews (100 x 4),Washers & Grommets

9584

9584

9584

9584

9584

9584

9584

9584

9584

Safety Hook

9889

9889

9889

9889

9889

9889

450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150 450 x 256 x 150

Ridge Ventilation Terminal Adaptor Flexible Pipe (100 to 100)

116 PRODUCT CODES

– –

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

9175 9172

• Terracotta and Brindle codes. Consult Customer Service Hotline for Black product codes.

Note all fittings are concrete unless marked # which are clay.

Safety Systems • Terracotta and Brindle codes. Consult Customer Service Hotline for Black product codes. Note all fittings are concrete unless marked

#

which are clay.

PRODUCT CODES 117


PERFORMANCE AND APPEARANCE Authority

Movement

All concrete slates and tiles conform to BS EN 490:2004: Concrete roofing tiles and fittings for roof covering and wall cladding – Product specifications. All clay tiles conform to BS EN 1304:2005: Clay roofing tiles and fittings – Product definitions and specifications. Redland Natural Slates have been tested in accordance with BS EN 12326-1:2004: Slate and stone products for discontinuous roofing and cladding. Product specification. As there is no British Standard for Cambrian Slate, it has been designed to meet the relevant performance requirements of BS 5534:2003: Code of practice for slating and tiling (including shingles) and has been awarded British Board of Agrément certificate No. 87/1907.

Designed vertical and horizontal laying tolerances will accommodate normal thermal and other movements.

Sustainability As members of the Concrete Tile Manufacturers Association and Clay Roof Tile Council, data supplied for our concrete and clay roof tiles enabled the 2008 BRE Green Guide to Specification to award the highest A+ rating for generic concrete and A+ or A rating for clay tiles depending on roof construction. Redland Cambrian Slates are the most eco-friendly resin slates available.The 2008 Green Guide to Specification awards generic resin slates an A rating when part of standard roof constructions.

Fire Resistance Cambrian Slates are classified as follows: EXT.S.A.A. when tested for fire protection to BS 476-3:2004: Fire tests on building materials and structures – Classification and method of test for external fire exposure to roofs. Class 2 when tested for surface spread of flame to BS 476-7:1997: Fire tests on building materials and structures – Method of test to determine the classification of the surface spread of flame of products. Fire propagation index 12.3 when tested to BS 476-6:1989: Fire tests on building materials and structures – Method of test for fire propagation for products. Under the Building Regulations there are no restrictions on the use of Cambrian Slates as a roofing material but for mansards above 69° or vertical slating, it is essential to comply with Approved Document B. All other slates and tiles are non-combustible and are classified S.A.A. when tested for fire protection and spread of flame to BS 476-3:2004: Fire tests on building materials and structures. There are no restrictions on their use under the Building Regulations.

Environmental Effects

Roof System Guarantee All of our products are designed and tested to work together. So not only is every product guaranteed weathertight, all the junctions between them are similarly guaranteed. If any Redland product fails during its first 15 years, we will not only replace it, we will also pay for the cost of labour and associated materials. Besides guaranteeing the tiles and slates, this guarantee includes all our fittings and accessories. Indeed, the guarantee is so comprehensive that it is transferable to all future owners. A complete Redland roof is a completely guaranteed roof.

Composition and Manufacture Concrete tiles and slates are manufactured by a high-pressure extrusion and compaction process. Rosemary clay plain tiles are extruded; Old Hollow and Cathedral clay pantiles are pressed. Redland Del Carmen natural slate is quarried in the Cabrera Mountains in north-western Spain and Redland Riverstone is mined from the San Luis quarry in central Argentina’s La Florida region. Cambrian Slates are manufactured from crushed Welsh natural slate (minimum content over 60%), stone, resin and glass-fibre reinforcement.

Performance All slates and tiles have been rigorously tested in our wind tunnel where combinations of high wind and driving rain are used to determine the products’ performance with respect to wind loading and weathertightness. Slates and tiles will meet the requirements of BS 5534:2003: Code of practice for slating and tiling, providing our fixing recommendations are complied with – refer to FixMaster on page 15. The information contained in this Guide relating to Cambrian, concrete slates and DuoPlain is based on a maximum rafter length of 10 metres. For rafter lengths greater than this, telephone the Technical Solutions Hotline on +44 (0)8708 702595 for advice.

Frost: unaffected by frost action. Heat: unaffected by temperature extremes. Sunlight: unaffected by prolonged exposure to ultraviolet light and sunlight. Atmospheric pollution: suitable for all rural, marine and normal industrial environments. Resistant to all but the most highly polluted atmospheres, where sulphur dioxide levels exceed 70 microgrammes/m3 of air. Redland Natural Slates are classified S1 under BS 12326 for resistance to pollution.

Biological Effects Birds and rodents: tiles and slates are not attacked, or degraded by birds, rodents or insects. Mosses and lichens: tile and slate durability is not affected by the growth of lichens and mosses. However, the removal of growths may be necessary when the flow of rainwater off the roof is impeded and valleys, gutters or downpipes become blocked.

Health & Safety Data sheets covering properties, storage and safe use of our products are available on request from Redland’s Safety Manager, telephone our Customer Service Hotline for details.When cutting tiles or slates using an angle grinder on a scale to generate large concentrations of dust, the measures defined in the Health and Safety Executive Guidance Note EH 40 must be followed.

Appearance Under normal production conditions colour variation may occur in slates, tiles and fittings. Natural weathering may also cause changes in colour and appearance. In both cases this is acceptable under BS EN 490. Scratches and abrasions caused by packing, loading and transportation are also permissible as long as the overall slate or tile quality is not affected.

Strength and Durability

Cambrian Slates can be pre-weathered during manufacture if required. After installation slight lightening may occur due to natural weathering. Landmark slates and tiles are designed to change over time, just as natural slate and clay mellow and develop character. With the exception of Landmark, efflorescence, which is a surface phenomenon associated with concrete products, may result in a temporary lightening of the surface colour.This will be removed by weathering.

Slates and tiles do not delaminate and despite having high strength properties, are easy to cut. All Redland clay and concrete slates and tiles exceed the minimum strength requirements as laid down in BS EN 1304 or BS EN 490 respectively. Redland Natural Slates exhibit high flexural strength and are tested in accordance with BS EN 12326-1:2004.

Natural Slates are devoid of artificial pigments but some natural colour variation, variability in grain and inclusions can occur. Redland Natural Slate products attain a T1 classification in BS EN 12326 and therefore oxidisation, change of appearance and colour changes which may affect the structure or form runs of discolouration are unlikely to occur.

The minimum pitch may be affected by roof features such as dormers, roof windows and chimneys. For advice on the inclusion of such features in a roof slope contact the Technical Solutions Hotline.

118 PERFORMANCE AND APPEARANCE

For the best visual effect on the roof, slates and tiles must be selected randomly from a minimum of three different pallets. When laying tiles in prominent areas it is advisable to ensure that there are sufficient stocks of mixed tiles available to complete the elevation. Slates or tiles of the same colour or profile, which are manufactured at different plants, must not be mixed on the same roof area.

Fixing Specification Every Redland Del Carmen and Redland Riverstone slate must be fixed with either copper or stainless steel nails or stainless steel hooks. There is only one recommended fixing specification for Cambrian Slates – they must be twice nailed and clipped using proprietary nails and clips. In addition, verge clips are required for every verge, raking valley cut and rooflight abutment. For information on how to obtain recommended fixing specifications for all other Redland slates and tiles, refer to FixMaster on page 15.

General Guidance

Special Notes on laying Natural Slates • All slates must be sorted into a minimum of three thicknesses prior to laying. • Thick slates should be laid at the eaves with the thinnest used on upper roof sections using slates of consistent thickness in any one course. • Fix each slate with two nails through prepared holes. • At all eaves, a double course of slates is required. • All slates should be laid broken bond and double lapped. • Form verges by using Standard Slates and Slate-and-a-halves in alternate courses. • At ridges and top edge abutments, a shouldered slate should be used in the course below the top course to enable the short top course slates to be nailed directly to the batten. • At hips and valleys, care should be taken to preserve an adequate bond by using Slate-and-a-halves. • When used with mechanically fixed ridge or top edge abutment systems, further fixing may be required. Please contact Technical Solutions. • Please contact Technical Solutions for use on Vertical or on Curved Roofs.

• •

For advice on the replacement of individual slates, contact the Technical Solutions Hotline. All mortar bedded hips/ridge must be mechanically fixed.

Special Notes on laying Plain Tiles At eaves, use double courses with purpose made Eaves/Top Tiles for the undercourse. • At verges and abutments to maintain broken bond, use Standard Plain Tiles and Tile-and-a-halves in alternate courses. • Adjacent to hips, valleys and angles use Tile-and-a-halves. • At side abutments, allow for stepped flashing and soakers. • At top courses use double courses with purpose made Eaves/Top Tiles for the top course. • For Winchester Cuts use two Tile-and-a-halves per course. Winchester Cut detail must not be used to abut roof pitches below 40º or in exposed locations. In these cases soldier or double soldier courses must be used. • For Heathland, Downland and concrete Plain Tiles secure top course with a Top Tile Clip with mortar bedded ridges and top edge abutments.

Special Notes on laying DuoPlain All tiles must be laid broken bond with a three-quarter tile offset, normally from right to left. On gable-to-gable roofs try and lay out the tiles so that the eaves course starts with a Standard Tile and finishes with a LH Verge (three quarter) Tile. • At right-hand verges use Standard Tiles and RH Verge (three quarter) tiles in alternate courses. • At left-hand verges use Standard Tiles with interlocks removed and LH Verge (Three Quarter) Tiles in alternate courses. If it is not possible to end the eaves course in this way, cut verge tiles of the required length from Tile-and-a-halves. • Do not use any cut pieces of tile smaller than a LH Verge (Three Quarter) Tile. • At hips and valleys use Tile-and-a-halves on each course either side. • At side abutments, allow for cover flashing and secret gutter.

Special Notes on laying Profile Tiles Tiles must be laid straight bonded, normally from right to left. Reform Eaves Filler Units must be used at all eaves situations with Landmark Double Pantile, Grovebury, Regent and Norfolk Pantile • Eaves Comb Fillers must be used at all eaves situations with Cathedral and Old Hollow Clay Pantiles. • At left-hand verges, use Standard Tiles with interlocks removed. At right-hand verges, use Standard Tiles. Half Tiles must not be used at verges. Use Left-hand Verge Tiles with Cathedral and Old Hollow Clay Pantiles. • Dentil slips must be used for mortar bedded ridges and hips with Cathedral and Old Hollow Clay Pantiles, Landmark Double Pantile, Landmark Double Roman, Grovebury, Regent, 50 Double Roman and Norfolk Pantile. • Half Tiles should be used with Landmark Double Pantile, Landmark Double Roman, Grovebury, 50 Double Roman, Regent and Renown to avoid the use of small pieces of tiles. Use Two-Thirds Tile with Cathedral Clay Pantile. • As Old Hollow Clay Pantiles have no interlocks, it is very important that perpendicular lines are struck prior to laying to ensure the correct side overlap is achieved.

Special Notes on laying Cambrian and Concrete Slates • All slates must be laid broken bonded, normally from right to left. MockBond Mini Stonewold should be laid with a 3/4 tile offset, as opposed to a standard 1/2 tile offset. • At the eaves for Saxon, Landmark Slate and Richmond use Eaves Slates. For all other slates use Standard Slates. • At right-hand verges for Cambrian Slates, use Standard Slates and Slate-and-a-halves in alternate courses. For all other slates except MockBond Mini Stonewold use Standard Slates and Right-hand Half Slates in alternate courses. For MockBond Mini Stonewold use standard slates (with interlocks removed) or Right-hand Half Slates and site cut 3/4 width slates in alternate courses. • At left-hand verges for Cambrian Slates, use Left-hand Verge Slates and Lefthand Verge Slate-and-a-halves in alternate courses. For all other slates except MockBond Mini Stonewold use Standard Slates with interlocks removed, and Left-hand Half Slates in alternate courses. For MockBond Mini Stonewold use Standard Slates (with interlocks removed) or Left-hand Half Slates and site cut 3/4 width slates in alternate courses. • At side abutments, allow for cover flashing and secret gutter. • At top courses and top edges for Saxon, Landmark Slate and Richmond use Top Slates. For all other slates use Standard Slates.

• •

Additional Notes when laying Cambrian Slates • For rafter pitches below 45º with mitred hip, Double Slates will be required on all courses either side of the hip. At pitches greater than this Slate-and-a-halves can be used. • For rafter pitches below 25º for valleys, dry and mechanically fixed bedded hip, Double Slates will be required on all courses either side of the valley or hip. At pitches greater than this Slate-and-a-halves can be used.

Roofing practice in Scotland includes the use of timber sarking and counterbattens. Insulation board is also widely used as rigid sarking throughout the UK.The presence of sarking board in either of these forms will affect many of our standard details. It must be noted that the combined thickness of the sarking and counterbatten chosen may alter details slightly. For insulation board, advice on the size and fixing of the counterbattens should be obtained from the specific insulation manufacturer.

Timber Sarking

PERFORMANCE AND APPEARANCE 119


RED1094_GTRS_GB_Codes.qxd

29/12/08

11:48

Page 120

INDEX A

H

Abutments Abutment GRP Secret Gutter Top Edge Ventilating Abutment Rapid Flashing Ambi-Dry Verge System Arrowhead Ornamental Tile

Heathland Hip Systems Dry Hip System Rapid Hip System Cambrian Mitred Hip

86 87 88 76 107

B Ball Top Finials (Short & Tall) Breathing Roof Bullnose Ornamental Tile

107 12 107

C CAD drawings (DesignMaster) Cambrian Slates Cambrian GRP Valley Cambrian Mitred Hip Cathedral Clay Pantile Classic Clay Tiles Cathedral Old Hollow Rosemary Cloaked Verge System Club Ornamental Tile Cockscomb Ridge Colour range - fittings CPD Craftsman Crested Ridge

15 22 85 82 50 36 50 48 34 74 107 107 108 4 34 107

D DesignMaster (CAD drawings) 50 Double Roman Downland Dry-fix roofing Abutments Hip Systems Ridge Systems Valleys Verge Systems Dry & DryVent Ridge System Dry Hip System DuoPlain

15 57 40 see A see H see R see V see V 90 78 44

E Eaves Ventilation RedVent Eaves Vent (10mm) RedVent 25 Over-Fascia (25mm) EcoMaster Estimating Service (QuantMaster)

72 73 16 15

F Finials Fixing Specifications (FixMaster) Fleur-de-Lys Finial & Ridge

107 15 107

G Gas Flue Terminals GRP Valley GRP Secret Gutter Grovebury Guarantees (see SpecMaster)

120 INDEX

96 84 86 56 10, 15

S 38 78 80 82

L Landmark Double Pantile Landmark Double Roman Landmark Slate Lead Alternatives Abutment GRP Secret Gutter Rapid Flashing Top Edge Abutment Ventilation 125 GRP Valley Cambrian GRP Valley

52 54 24 86 88 87 84 85

T

62 30 31

U

20 60

V

M Metal Roofing Mini Stonewold MockBond Mini Stonewold

N Natural Slate Norfolk Pantile

O Old Hollow Clay Pantile Ornamental Finials,Tiles & Ridges

48 106

P Performance & Appearance Plain Tiles clay concrete Profile Tiles

118 34 38 46

Q QuantMaster (estimating service)

15

R Rapid Flashing Rapid Hip System Redland 49 Tile Redland 50 Double Roman RedLine Ventilation for Tiles & Slates for Plain Tiles RedVent Eaves Vent (10mm) RedVent 25 Over-Fascia (25mm) Regent Renown Richmond Ridge Systems Dry & DryVent Ridge Rapid Ridge & Rapid Vented Ridge Ridge Ventilation Terminals Ridge Ventilation Terminal Rosemary Classic Rosemary Craftsman

Safety Hook System Saxon Scroll Finial Secret Gutter (GRP) Slates Solar Water Heating Systems Specification writing (SpecMaster) Spirtech 250 Stonewold II Sustainability

88 80 61 57 100 102 72 73 58 59 28 90 92 94 94 34 36

Technical Solutions Three Hole Crested Ridge ThruVent Tiles Top Edge Ventilating Abutment Training & Resource Centre

Underlays Underlay Support Tray Universal Rapid Vented Ridge System

89 26 107 86 18 66 15 70 29 6

14 107 104 87 4

70 70 92

Valleys 125 GRP Valley 84 Cambrian GRP Valley 85 Vapour Permeable Underlay 70 Veltitech 70 Ventilation 11 Ventilation Systems Eaves see E Ridge see R ThruVents see T Vent Tiles see RedLine & ThruVent Verge Systems Ambi-Dry Verge (for slates & 6 profile tiles) 76 Cloaked Verge (for 6 profile tiles) 74 ViewMaster 16

W Website

17

Z Zonal Fixing Specifications

15


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.