W W W . H A N D E L A R C H I T E C T S . C O M
GL A SS
W W W . H A N D E L A R C H I T E C T S . C O M
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
GL A SS
WHY WE LIKE GLASS
W ITHOUT
GUILT
GL A SS
requires a lot of energy to make...
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
contributes to global warming...
In the United States, buildings accounted for 41% of primary energy consumption, representing 7% of global primary energy consumption.1 United States Department of Energy, 2010
1
GL A SS
wrecks art...
W ITHOUT
GUILT
GL A SS
burns people... melts coffee cups...
Las Vegas hotel guests left with severe burns from 'death ray' caused by building's design By Daily Mail Reporter UPDATED:05:53 EST, 29 September 2010 Guests at a new hotel in Las Vegas have complained of receiving severe burns from a 'death ray' of sunlight caused by the unique design of the building. Due to the concave shape of the Vdara hotel, the strong Nevada sun reflects off its all-glass front and directly onto sections of the swimming pool area below. The result has left some guests with burns from the powerful rays and even plastic bags have been recorded as melting in the heat.
Death ray: Guests at the Vdara hotel in Las Vegas have complained of receiving severe burns from the intense spot of sunlight reflected off the building
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
kills birds...
In North America, estimates are that 100 million to 1 billion birds die from glass impact each year.1
Powdermill Avian Research Center
1
GL A SS
UTOPIA
W ITHOUT
GUILT
DYSTOPIA
GL A SS
Fewer small windows in a well-insulated wall.
W ITHOUT
GUILT
GL A SS
Improvements in Technology
W ITHOUT
GUILT
GL A SS
W ITHOUT
CLIMATE MAT TERS
USE MAT TERS
PERFORMANCE
ORIENTATION MAT TERS
SHAPE MAT TERS
GUILT
GL A SS
What metrics do we use? U-Value Shading Coefficient (SC)
R-Value
Visible Light Transmission (VLT) Solar Energy Transmittance Relative-Heat Gain (RHG) Solar Energy Reflectance .5) 9LVLEOH ,QGRRU 5Hテ?FWDQFH Solar Heat Gain
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
What metrics do we use? New York City Green Building Code gives you a bonus for adding insulation but you can still use PTACs.
The average room air conditioner and PTAC leaks as much air as a six square inch hole—and increases total annual heating costs by $130-$180 million in New York City alone. The leaks account for 1% of citywide greenhouse gas emissions. Source: Steven Winter Associates
GL A SS
CLIMATE Mat ters
Solutions vary...
DRY
HOT
TEMPERATE
COLD
WET
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
ORIENTATION Mat ters
Effect of Building Orientation, New York City
S
W
E N
Glazing Type 1: Single Glazing Glazing Type 2: Double Glazed, No Low E-Coating Glazing Type 3: High Performance Double Glazed (Low E-Coating) Glazing Type 4: Triple Glazed, Low E-Coating Source: BuildingGreen.com
GL A SS
W ITHOUT
GUILT
SHAPE Mat ters
Building 1: 100,000 Sq. Ft.
Building 2: 100,000 Sq. Ft.
Building 3: 100,000 Sq. Ft.
Glazing Type 3: High Performance Double Glazed (Low E-Coating) Glazing Type 4: Triple Glazed, Low E-Coating Source: BuildingGreen.com
GL A SS
10 TYPE 2
8
TYPE 3
6
TYPE 4
4 2 0
20% 40% 60% 80% Gross Facade Percentage
NEW YORK
GUILT
TYPE 1 Single Glazing TYPE 2 Double Glazed, No Low E-Coating TYPE 3 High Performance Double Glazed (Low E-Coating) TYPE 4 Triple Glazed, Low E-Coating
12 10 TYPE 1
8
TYPE 2 TYPE 3
6
TYPE 4
4 2 0
20% 40% 60% 80% Gross Facade Percentage
MIAMI
Energy Consumption (106 Btu/yr)
TYPE 1
12
Energy Consumption (106 Btu/yr)
Energy Consumption (106 Btu/yr)
Annual energy consumption is compared for a 100,000 sf square building in three different cities and with four glazing types as the glazing areas is increased from 20% to 80%.
W ITHOUT
12 10 8
TYPE 1 TYPE 2
6
TYPE 3
4
TYPE 4
2 0
20% 40% 60% 80% Gross Facade Percentage
SAN FRANCISCO
Energy consumption is shown in million Btus per year (mmBtu/yr) for the building, including cooling, heating, ventilation, lighting (1.2 watts/ft2), and miscellaneous loads (1.5 W/ft2). Source: BuildingGreen.com
GL A SS
W ITHOUT
GUILT
USE Mat ters
%
U.S. COMMERCIAL SECTOR USE TOP 5 IN 2010
%
30
30
25
25
20
U.S. RESIDENTIAL SECTOR USE TOP 5 IN 2010 28.9%
20
19.7% 15.3%
15
14.1%
10
12.9%
14.0%
15
9.0%
10
8.9%
7.1% 6.5%
5 0
LI
G
HT
IN
G
SP AC E
HE
SP AC E AT I
N
G
VE CO
O
LI
N
N
TI
G
RE LA TI
O
N
5 0 FR
IG
ER
AT I
O
N
SP AC E
HE
SP AC E AT I
N
G
CO
W AT E O
LI
N
G
LI R
HE
AT I
G
N
HT
G
EL IN
G
EC
TR
O
N
IC
S
Source: US Department of Energy
GL A SS
W ITHOUT
GUILT
What is a GL ASS BUILDING?
40 BOND STREET has a total opaque facade area of 65% of the building, and a total vision glass area of 35% of the building.
LEOBEN JUSTICE CENTRE IN AUSTRIA has a total opaque facade of 9% of the building and a total vision glass area of 91% of the building.
GL A SS
W ITHOUT
GUILT
GLAZING TECHNOLOGY DEVELOPMENTS
1928 Safety glass available
1940s Postwar building boom
for PPG. Developed for the automobile industry, the ‘Creighton Process’ bonds two plies of glass with a layer of cellulose acetate.
calls for more plate glass use in commercial construction than ever before. 1945 Double insulating glazing
introduced into the building market. It was first developed for railroad passenger cars.
1900
1910
1920
1930
1940
1950
1918 Hallidie building :
1952 Float glass intro-
development of curtain wall glazing.
duced in England by Pilkington Glass Ltd., revolutionizing glass manufacture.
Ź
GL A SS
W ITHOUT
GUILT
What was the performance of a late 1950s or early 1960s curtainwall? How has the technology improved?
LEVER HOUSE, 1952
U-value of glazing of Lever House in 1952 was 1.01. Source: CTBUH
GL A SS
W ITHOUT
BASELINE
Early 1950’s fleet: Avg of 12 MPG
GUILT
GL A SS
W ITHOUT
GUILT
GLAZING TECHNOLOGY DEVELOPMENTS
1970s Building code changes
1979 Neutral colored, architectur-
following the energy crisis of 1973 begin to force a widespread switch to double glazing.
ally acceptable low-E coatings (softcoat on glass) first become available.
1961 Metalized window films
1979 Argon-filled low-e double
for solar control introduced.
glazing available in Germany.
1960
1970
1980 1978 Southwall Technologies
introduces ‘Heat Mirror.’ in which a low-e coated film is suspended within an insulating glass unit, creating a triple glazed unit with a weight of a double glazed unit. 1966 Ford acquires the rights
to the Pilkington float glass process and begins to produce the first float glass in the U.S..
Ź
GL A SS
W ITHOUT
GUILT
GLAZING TECHNOLOGY DEVELOPMENTS
1984 First prototype of a ‘mini-float’
By 1993 one third of residential windows sold and one fifth of commercial windows sold employ low-E coatings.
plant opened by AFG Technologies.
1989 Pyramid of the Grand
Louvre is clad with insulating units made with a 10mm glass with low iron content.
1980
1990
2000
Ź
1989 ‘Superwindow’ marketed
using two suspended layers of 0.10 emissivity polyester film within Krypton gas filled units. 1989 ’Hard coat’ low-E coating is
produced by Pilkington and LOF.
Between 1974 and 1994 the ratio of glass area/floor area in the typical U.S. house increases by 25%.
2006 Triple-Silver low-E
coatings are introduced, with a new level of spectral selectivity to let in natural light while blocking solar heat.
GL A SS
W ITHOUT
GUILT
U-value of glazing of Lever House in 1952 was 1.01. After curtainwall upgrade in 1998, U-value of glazing of Lever House reduced to ~ 0.220.
LEVER HOUSE, 1998
GL A SS
Early 1950’s fleet: Avg of 12 MPG
W ITHOUT
GUILT
1998 fleet: Avg of 22 MPG Improvement of < 200%
GL A SS
W ITHOUT
AREAS OF IMPROVEMENT GLAZING Insulated glazing, multiple glazing, gasямБlled, vacuum glazing, spacer materials FRAMING All metal, thermally broken, non-metal CASSETTE SYSTEMS SHADING Static, active, adaptive DOUBLE SKIN FACADES COATING TECHNOLOGIES photochromic, thermochromic, electrochromic, bird friendly glass ENERGY GENERATING FACADES DEPOLLUTING COATINGS
GUILT
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Single-Glazed Clear 1.04 U-FACTOR 0
1 0.86
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Single-Glazed Tinted 1.04 U-FACTOR 0
1 0.73
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Double-Glazed (IG) Clear 0.48 U-FACTOR 0
1 0.76
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Double-Glazed (IG) Tinted 0.49 U-FACTOR 0
1 0.63
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Double-Glazed (IG) High-Solar-Gain Low-e 0.26 U-FACTOR 0
1 0.67
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Double-Glazed (IG) Medium-Solar-Gain Low-e 0.25 U-FACTOR 0
1 0.2
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Double-Glazed (IG) Low-Solar-Gain Low-e 0.24 U-FACTOR 0
1 0.26
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Triple-Glazed High-Solar-Gain Low-e 0.16 U-FACTOR 0
1 0.55
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Triple-Glazed Medium-Solar-Gain Low-e 0.15 U-FACTOR 0
1 0.38
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GUILT
GLAZING IMPROVEMENTS
Triple-Glazed Low-Solar-Gain Low-e 0.15 U-FACTOR 0
1 0.24
SHGC 0
1
Source: EfямБcient Windows Collaborative
GL A SS
W ITHOUT
GLAZING IMPROVEMENTS
Quad-Cavity R20 Glazing
0.05 U-FACTOR 0
1
0.12 SHGC 0
1
Source: Southwall Technologies
GUILT
GL A SS
W ITHOUT
GLAZING IMPROVEMENTS
1.04
GUILT
U-FACTOR SHGC
1.04 0.86 0.76
0.73
0.67
0.63
0.55 0.48
0.49 0.38 0.26
0.25
0.2
0.24 0.26
0.24 0.16
0.15
0.15
0.12 0.05
Si n
Q Do Do Tr Tr Do Tr u i i i G G L L L G p p p ub ub gl gl ow ub ow ub ow le ai le la ad ai u b l e een -G n le zin -C le le -G - e le - e le -e -G G G Lo la Lo - G -G -G l l G G g av la la a a w w la la l la la z z z it y ze ze a ed ed - e ed -e ze ze ze ze ze d, d, R2 ,H ,L ,M d d d d d Cl Ti ( ( ( ( ( o 0 i I I I I I e g G) G) G) G) G) nt w ea d h -S ed ,C ,L ,T ,H ,M iu -S r ol m o o in le i ed ar gh la w te S ar r-G -S o iu -S d l ol a m ol ai r-G ar -S ar n -G ol -G ai Lo ar ai n ai w n n -e Si n
Do
Source: EfďŹ cient Windows Collaborative
Do
GLAZING IMPROVEMENTS,WHOLE WINDOW
GL A SS
W ITHOUT
hͲsĂůƵĞ
GUILT
^,'
Single-Glazed, Clear Glass Façade, Metal Frame Single-Glazed, Clear Glass Façade, Non-Metal Frame
шϭ͘ϬϬ 0.71-0.99
шϬ͘ϲϬ шϬ͘ϲϭ
Single-glazed, Tinted Glass Façade, Metal Frame Single-glazed, Tinted Glass Façade, Non-Metal Frame
шϭ͘ϬϬ 0.71-0.99
>0.60 0.41-0.60
Double-glazed, Clear Glass Façade, Metal Frame Double-glazed, Clear Glass Façade, Metal Frame with Thermal Break Double-glazed, Clear Glass Façade, Non-Metal Frame
0.71-0.99 0.56-0.70 0.41-0.55
0.41-0.55 >0.60 0.41-0.60
Double-glazed, Tinted Glass Façade, Metal Frame Double-glazed, Tinted Glass Façade, Metal Frame with Thermal Break Double-glazed, Tinted Glass Façade, Non-Metal Frame
0.71-0.99 0.56-0.70 0.41-0.55
0.41-0.60 0.41-0.60 0.41-0.60
Double-glazed, High-performance Tinted Glass Façade, Metal Frame Double-glazed, High-performance Tinted Glass Façade, Metal Frame with Thermal Break Double-glazed, High-performance Tinted Glass Façade, Non-Metal Frame
0.71-0.99 0.56-0.70 0.41-0.55
0.41-0.60 0.41-0.60 0.26-0.40
Double-glazed, High-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame Double-glazed, High-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame with Thermal Break Double-glazed, High-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame Double-glazed, High-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Themally Improved
0.56-0.70 0.41-0.55 0.41-0.55 0.23-0.30
>0.60 0.41-0.60 0.41-0.60 0.41-0.60
Double-glazed, Medium-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame Double-glazed, Medium-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame with Thermal Break Double-glazed, Medium-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame Double-glazed, Medium-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Thermally Improved
0.56-0.70 0.41-0.55 0.41-0.55 0.23-0.30
0.26-0.40 0.26-0.40 0.26-0.40 0.26-0.40
Double-glazed, Low-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame Double-glazed, Low-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Metal Frame with Thermal Break Double-glazed, Low-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame Double-glazed, Low-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Thermally Improved
0.56-0.70 0.41-0.55 0.41-0.55 0.23-0.30
чϬ͘Ϯϱ чϬ͘Ϯϱ чϬ͘Ϯϱ чϬ͘Ϯϱ
Triple-glazed, High-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Thermally Improved Triple-glazed, Medium-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Thermally Improved Triple-glazed, Low-solar-gain Low-E Glass, Argon/Krypton Gas Façade, Non-Metal Frame, Thermally Improved
чϬ͘ϮϮ чϬ͘ϮϮ чϬ͘ϮϮ
0.41-0.60 0.26-0.40 чϬ͘Ϯϱ
dŚĞƌŵŽ ƵWs Ρ ͗ dƌŝƉůĞͲŐůĂnjĞĚ͕ >ŽǁͲ 'ůĂƐƐ ;ZϭϭͿ͕ ůƵƉůĂƐƚ ƉƌŽĨŝůĞƐ ǁŝƚŚ ƐƚĞĞů ƌĞŝŶĨŽƌĐĞŵĞŶƚ dĞƌŵŽ tŽŽĚΡ dƌŝƉůĞͲŐůĂnjĞĚ͕ >ŽǁͲ 'ůĂƐƐ ;ZϭϭͿ͕ tŽŽĚ &ƌĂŵĞ ǁŝƚŚ ůƵŵŝŶƵŵ ƌĂŝŶ ŐƵĂƌĚƐ dŚĞƌŵŽWůƵƐ ůĂĚΡ ͗ dƌŝƉůĞͲŐůĂnjĞĚ͕ >ŽǁͲ 'ůĂƐƐ ;ZϭϭͿ͕ ůƵŵŝŶƵŵ ůĂĚ tŽŽĚ &ƌĂŵĞ ǁŝƚŚ WƵƌĞŶŝƚΡ ŝŶƐƵůĂƚŝŽŶ
0.14 0.14 0.123
0.5 0.5 0.5
Source: Efficient Windows Collaborative / Zola Windows
SPACER IMPROVEMENTS
GL A SS
Sealant
Desiccant Primary Sealant
Metal with Butyl Tape
Secondary Sealant
Metal Spacer Desiccant
Super Spacer
Primary Sealant
Corrugate metal strip
Butyl Tape
Secondary Sealant
Sealant
Sealant
Spacer System 1. Aluminum box / PIB / silicone 2. Tin U-channel / butyl 3. Stainless box / PIB primary sealant 4. Stainless Steel U-channel / butyl 5. Coated corrugated plastic / butyl 6. Super Spacer Structural foam / butyl
GUILT
Stainless Steel Spacer
Aluminum box PIB / Silicone
W ITHOUT
Effective Thermal Conductivity
Total IGU U-factor
8 .t,
0.329
8 .t,
0.304
8 .t,
0.293
8 .t,
0.287
8 .t,
0.286
8 .t,
0.277
Simulations performed by Enermodal Engineering Ltd. using Windows 5.2 and Therm 5.2 as per NFRC100-2011. Outside temperature 0Ă&#x201A;°F. Inside temperature 70Ă&#x201A;° F. Low-E glass is Cardinal Low-E 272. All air spaces are .500" wide. IGUs are 24" x 48". [Test Reports EIG906w, EIG10005, EIG10009w]
Source: Enermodal Engineering
GL A SS
W ITHOUT
GUILT
FRAMING IMPROVEMENTS
ak
re al b
erm
in
um
m Alu
e ram
th ut
tho
wi
f
m Alu
in
um
e ram
rm
he ht
me
wit
f
Current technology with standard thermal breaks has improved aluminum frame U-factors from roughly 2.0 to about 1.0.
ak
re al b
yl Vin
s
me
fra
a s fr
rid
b Hy
fra
me
ted
la erg
fib
a
ul Ins
Innovative new thermal break designs have been combined with changes in frame design to achieve U-factors lower than 0.5
d
o Wo
me
cla
ra df
df
o Wo
C™
e ram
o
rm he
T
Wood-framed windows perform well with frame U-factors in the range of 0.3 to 0.5.
V uP
erm
Th
d™
oo oW
d™
la oC
erm
Th
High performance passive house windows achieve U-factors lower than 0.13.
Source: Efficient Windows Collaborative
GL A SS
Roughly 100 MPGe
W ITHOUT
GUILT
GL A SS
W ITHOUT
SHADING IMPROVEMENTS
Heat Rejection
Good
Better
Interior Shades
Between-Pane Shades
Best Exterior Shades
GUILT
GL A SS
W ITHOUT
The FC value has been used as the common denominator to evaluate the effectiveness of sun-shading systems. It describes the relationship between the energy transmittance coefficient of a window with or without solar shading.
SOLAR SHADING SYSTEM
Fc values
Without solar shading system
1.00
Internal or Between the Panes Dark colors or higher transparency Light colors or low transparency White or reflective surface with low (<20%) transparency
0.90 0.80 0.75
External Awnings, general Canopies, loggias Awnings with top and side ventilation Roller shutters, folding shutters External venetian blinds and materials with low (<20%) transparency
0.50 0.50 0.40 0.30 0.25
Note: Values refer to a fixed solar shading system. Standard decorative curtains do not qualify as solar shading systems.
Source: plusminus20o/40olatitude by Schuco
GUILT
GL A SS
STATIC SHADING
ADAPTIVE SHADING
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
0% SAVINGS: SHADING BASELINE Traditional code-compliant façade designs sacrifice daylight to reduce HVAC energy use due to solar and conductive loads. The daylit zone is typically at most 15 feet deep and is compromised by manually-operated interior shades that significantly reduce daylight and view.
Window Heat Gain
c/o lowenergyfacades.lbl.gov
GL A SS
W ITHOUT
GUILT
20% SAVINGS: INTEGRATED DAYLIGHTING SOLUTIONS Intelligent, dynamic and/or light-redirecting faรงades combined with automated lighting controls can extend the daylit zone up to 20-30 feet deep by actively balancing daylight and thermal loads on a real-time basis while mitigating sunlight and glare. This approach, however, requires careful space planning.
Automated Shades
The New York Times Headquarters : 100% lighting controls, and automated shades.
c/o lowenergyfacades.lbl.gov
GL A SS
W ITHOUT
GUILT
INTEGRATED DESIGN INTEGRATED FAÇADES WITH LOW-ENERGY COOLING juwi Group Headquarters in Wörrstadt, Germany : 183,000 SF Office Building that generates more energy than it uses. Solar electricity produced on a surface of 32,000 SF.
Combine high-performance façades, daylighting, and low-energy cooling strategies such as natural ventilation and radiant cooling to eliminate the HVAC system entirely in some climates. High-R windows and dynamic façades can significantly reduce thermal loads during critical peak periods while maintaining high daylight efficiency. Use building integrated photovoltaics for energy supply. c/o lowenergyfacades.lbl.gov c/o juwi.com
GL A SS
COATING TECHNOLOGIES
: photochromic, thermochromic (passive); electrochromic (active)
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
ELECTROCHROMIC GLASS
dŝŶƚ >ĞǀĞů LJŶĂŵŝĐ ϲϬ LJŶĂŵŝĐ ϰϬ LJŶĂŵŝĐ ϮϬ LJŶĂŵŝĐ ϰ
dƌĂŶƐŵŝƚƚĂŶĐĞ й
ZĞĨůĞĐƚĂŶĐĞ й
sŝƐŝďůĞ
hs
^ŽůĂƌ
sŝƐŝďůĞ KƵƚ
sŝƐŝďůĞ /Ŷ
^ŽůĂƌ KƵƚ
хϲϬй ϰϬй ϮϬй фϰй
Ϭ Ϭ Ϭ Ϭ
ϯϳ͘ϴ ϭϳ͘Ϯ ϳ͘Ϭ Ϭ͘ϵϯ
ϭϳ͘ϰй ϵ͘ϰй ϳ͘ϰй ϳ͘ϱй
ϭϵ͘Ϯй ϭϳ͘ϵй ϭϲ͘ϵй ϭϲ͘Ϯй
ϭϴ͘ϳй ϭϭ͘ϭй ϭϭ͘ϭй ϭϮ͘ϴй
hͲsĂůƵĞ ; dhͬ,Z͘ &dϮ&Ϳ
SHGC ^,'
Ϭ͘ϯϴ Ϭ͘ϯϴ Ϭ͘ϯϴ Ϭ͘ϯϴ
Ϭ͘ϰϳ Ϭ͘Ϯϳ Ϭ͘ϭϳ Ϭ͘ϭϭ
Dynamic 60:
Dynamic 40:
Dynamic 20:
Dynamic 4:
0.47 SHGC, >60% Transmitted Light
0.27 SHGC, 40% Transmitted Light
0.17 SHGC, 20% Transmitted Light
0.11 SHGC, <4% Transmitted Light Images c/o Soladigm
GL A SS
W ITHOUT
GUILT
SUSPENDED PARTICLE DEVICE (SPD) windows can
instantaneously be adjusted to “tune” the amount of light, glare and heat passing through the windows. Regulating the voltage to the film adjusts microscopic particles’ orientation, instantly and precisely controlling the passage of light, glare and heat through the film. SPD-SMART film is laminated between panes of glass or plastic substrates. Source: SPD-SmartGlass
GL A SS
W ITHOUT
GUILT
PRINTABLE TECHNOLOGIES :
Organic thin-film, or plastic solar cells, use low-cost materials primarily based on nanoparticles and polymers. They are formed on inexpensive polymer substrates which can take advantage of the relatively inexpensive “roll-to-roll” production methods used in newspaper presses.
Source: Nanotechnology for Green Building
GL A SS
DOUBLE SKIN FACADES
W ITHOUT
GUILT
The most energy efficient double skin glass façade is about 22.84% more efficient than the most energy efficient single skin glass façade.1 Building energy modeling of double skin facades is inherently more difficult because of varying heat transfer properties within the cavity, making the modeling of energy performance and the prediction of savings debatable.2
Source: Journal: Energy and Buildings - ENERG BLDG , vol. 37, no. 6, pp. 673684, 2005 2 Source: American Society of Heating, Refrigerating and Air-Conditioning Engineers 1
GL A SS
VENTILATED MICROCAVITIES
Both vents closed
Both vents fully y opened p
W ITHOUT
GUILT
Outside vent closed
Multifunctional windows that offer insulation, sunscreen, ventilation and sound reduction properties. Involves two separate layers of glass (can be either single layer or insulated glass), where each layer is divided to allow small vents to be opened independently.
Source: Hansen Group
GL A SS
W ITHOUT
GUILT
BIRD FRIENDLY GLASS
WHAT WE SEE: light at wavelengths between 400 and 700 nanometers.
WHAT THE BIRDS SEE: the UV range as well, from 320 to 400 nanometers. (A design prototype on Vassarâ&#x20AC;&#x2122;s campus using Ornilux Mikado glass)
Images c/o Ornilux
GL A SS
W ITHOUT
GUILT
ENERGY GENERATING GLASS Transparent Photovolatic Glass Generates 4.275 - 5.3 W/Sq. Ft. vs. 8 - 10 W/Sq. Ft. for typical photovoltaic panel
Images c/o MSK Solar Buildings | Onyx Solar
GL A SS
W ITHOUT
GUILT
VACUUM-FILLED OR AEROGEL IGUS. Aerogel
is just 5 percent solid and 95 percent air, and is said to be the lightest weight solid in the world. A 3.5â&#x20AC;? thick aerogel panel can offer an R-value of R-28. (Source: Sandia National Laboratory)
Nanogel panels provide translucency and insulation. High-insulating Nanogel panels are available with up to 75 percent translucency. (Source: Kalwall)
GL A SS
W ITHOUT
GUILT
NANOPARTICLE
Titanium dioxide nanoparticles acting as a catalyst to form reactive hydroxyl radicals can oxidize and destroy most pollutant molecules, and remove nitric oxide from the atmosphere.
CONVENTIONAL GLASS
GLASS PRODUCT WITH PHOTOCATALYTIC AND HYDROPHILIC PROPERTIES
Source: California Energy Commission
GL A SS
W ITHOUT
GUILT
CASSETTE SYSTEMS : ADAPTIVE OVER TIME
c/o Enclos Corp.
GL A SS
W ITHOUT
GUILT
ADVANCED WINDOWS CAN BECOME ENERGY PRODUCERS (US Mixed and Northern Climates) U-factor Single Glaze U=1
1
Double Glaze U = 0.5
0.5
R6 Window U = 0.17 (Dynamic Niche)
Low “e” U = 0.35
LOSS
R10 Window U = 0.10 (Dynamic Wide Spread)
GAIN
0 1975
1985
1995
2005
2015
2025
Year
Source: US Department of Energy
GL A SS
IMAGING IF WE COULD PUT IT ALL TOGETHER
Bird friendly
S lf Self cleaning and air cleansing
Adaptive over time
Tunable shading
Superior insulating Energy generating qualities
W ITHOUT
GUILT
GL A SS
W ITHOUT
GUILT
GL A SS
W W W . H A N D E L A R C H I T E C T S . C O M