T-36 User Guide

Page 1

Controls 24v Controls

T-36 Room Thermostat User Guide

T-36 Room Thermostat

john.ashford@uponor.com

Uponor Limited Head Office Gilmorton Road Lutterworth Leicestershire LE17 4DU

T 01455 550355 F 01455 550366 E enquiries.uk@uponor.com W www.uponor.co.uk


T-36 Operating Buttons

T-36 Menu Tree

T-36 Room Thermostat

Button Description

Parameter and Mode Settings Menu To enter the parameter and mode settings menu: 1. Press and hold the OK button for three seconds to enter the settings menu.

The OK button is used to: 2. Press the + button repeatedly to reach the other menus.

Enter and exit the settings menu Confirm a setting

The menus are presented in the following order: Select comfort or economy mode

The minus and plus sign buttons are used to:

MOD (regulation choices) BAL (balancing mode) ECO (economy mode) CAL (calibration) OFF (standby mode) 3. Press the - button to run the menu sequence in Opposite order.

Set the temperature setpoint Toggle between comfort and economy modes

4. Press and hold the OK button for three seconds to exit the settings menu.

Modify settings in the settings menus Enter and exit the lock mode (press and hold simultaneous for 3 seconds)

john.ashford@uponor.com 2012


T-36 Operating Buttons

Power-up

Run Mode ( Continued )

At power-up the thermostat designation, T-36, and the software version is shown for three seconds.

Example:

Then the thermostat enters into run mode.. Example:

In the example above the following is displayed:

• System works in heating mode • Room temperature is 22.3 °C • System works in comfort mode

Run Mode Run mode display description

• System works in auto-balancing mode, heating demand is on

In run mode the screen displays the following: • Room temperature in degrees Celsius • Heating or cooling icon depending on system working mode • ECO or comfort mode icon depending on system working mode • Heating/Cooling demand icon if a demand is present • Standby icon if the system is set in standby mode

ECO – Economy Mode (T-36 only) The economy mode menu is used to set the setback temperature for economy mode. In heating mode, the setback temperature is negative, in cooling mode it is positive. Activation and deactivation of the economy is done from the run mode screen,

• Holiday mode icon and remaining days if system is set in holiday mode

1. When ECO is displayed, press OK to enter the menu.

• Lock mode icon if the thermostat is set in lock mode

The screen displays the setback temperature.

• Manual override icon if the system is set in forced comfort or ECO mode • If a connected floor sensor is faulty, this is indicated by a flashing star to the left of the displayed room temperature

2. Press the + or - button to change the setting. Default setting: 4 °C Setting range: 0 – 11 °C Setting accuracy: 0.5 °C 3. Press OK to confirm the setting and proceed to the next menu.

john.ashford@uponor.com 2012


T-36 Operating Buttons

Setting forced ECO or comfort mode To set the system in forced ECO or comfort mode: 1. Press the OK button. The house icon starts flashing.

MOD – Regulation Choices The regulation choices menu is used to set the regulation mode of the thermostat. 1. When MOD is displayed, press OK to enter the menu.

2. Press the + or - button to change from comfort to ECO mode or the other way around. 3. Press the OK button. The screen returns to run mode displaying the selected ECO or comfort mode and the manual override icon.

The screen displays one of the following: • RT – room sensor regulation • RFT – room sensor regulation with floor sensor limitation • RS – remote sensor regulation 2. Press the + or - button to change the setting.

To remove forced mode:

3. Press OK to confirm the setting.

1. Press and hold the OK key for 3 seconds.

If RT or RS regulation mode is selected, the next menu is displayed, see section

The manual override icon

disappears and

the system returns to the mode, ECO or Comfort, as defined by the programming. Parameter and Mode Settings Menu To enter the parameter and mode settings menu: 1. Press and hold the OK button for three seconds to enter the settings menu. 2. Press the + button repeatedly to reach the other menus. The menus are presented in the following order:

If RFT regulation mode is selected, the next regulation setting, is displayed. 4. (Heating mode only) The symbol (heating mode) and MAX is displayed (maximum floor temperature limitation). 4.1. Press OK to display the limitation temperature. 4.2. Press the + and - buttons to change the setting. Default setting: 26 °C Setting range: 20 – 35 °C 4.3. Press OK to confirm the setting. 5. (Heating and cooling modes)

Uponor Thermostat T-36

The heating or cooling icon and MIN is displayed (low floor temperature limitation).

• MOD (regulation choices) • BAL (balancing mode) • ECO (economy mode) • CAL (calibration) • OFF (standby mode)

5.1. Press OK to display the limitation temperature. 5.2. Press the + and - buttons to change the setting.

3. Press the -button to run the menu sequence in opposite order.

Default setting: 20 °C Setting range: 10 – 35 °C

4. Press and hold the OK button for three seconds to exit the settings menu.

Press OK to confirm the setting

john.ashford@uponor.com 2012


T-36 Operating Buttons

BAL – Balancing Mode

OFF – Standby Mode

The balancing mode menu is used to select between manual and auto-balancing. The auto-balance function removes the need for manual balancing of the manifold at installation. The principle for automatic balancing is that the energy required by each loop is distributed in pulses. The length of the pulses in each loop is calculated from the actual heat demand of the room. 1. When BAL is displayed, press OK to enter the menu.

In standby mode, the regulation of the room temperature is disabled, but thermostat still displays the current room temperature. Entering standby mode 1. Press OK to confirm the standby mode. The standby icon and the room temperature is displayed. Exiting standby mode 1. Press and hold OK for three seconds. The thermostat name and software version are displayed for two seconds. Then the thermostat enters run mode.

The screen displays one of the following: • MAN – manual balancing • AB – automatic balancing

Lock Mode

2. Press the + or - button to change the setting. 3. Press OK to confirm the setting

The three operating buttons can be locked to prevent unintentional use. Entering lock mode

CAL – Calibration The calibration menu is used to adjust the temperature sensor in the thermostat.

1. Press and hold the + and - buttons simultaneously for three seconds.

1. When CAL is displayed, press OK to enter the menu.

The lock icon appears. Other displayed Information remains and the thermostat operates as set-up.

The room temperature is displayed.

Exiting lock mode

2. Press the + and - buttons to change the setting in 0.1 °C steps.

1. Press and hold the + and - buttons simultaneously for three seconds.

Setting range: -3 °C to +3 °C

The lock

3. Press OK to confirm the setting.

john.ashford@uponor.com 2012

icon disappears.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.