Lighting portfolio ashwini kokate mbs

Page 1


ARCHITECTURAL PORTFOLIO

PROFESSIONAL PROJECTS

1. SIGNIA ISLES SHOW FLAT 2. HOP ‘N’BOP (CHIDREN’S PLAY AREA)

ACADEMIC PROJECTS 1. ENVIRONMENTAL LIGHTING AND DESIGN 2. INFORMAL SCHOOL IN JAISALMER,INDIA 3. OTHER RENDERINGS 4. LIGHTING DESIGN FOR A BAR


DESIGNING THE SAMPLE FLAT THIS PROJECT WAS DONE DURING MY INTERNSHIP, I WAS APART OF THE TEAM THAT DESIGNED THE INTERIORS AS WELL AS THE LIGHTING FOR THE SHOW FLAT . THIS PROJECT REQUIRED A SOLID CONCEPT AND A MUTE BUT SPECIFIC COLOUR PALLETTE.




DESIGNING FOR CHILDREN’S PLAY AREA THIS PROJECT WAS DONE IN THE SPAN OF 3 MONTHS. I WAS HEAVILY INVOLVED IN THE MAKING THE ELECTRICAL DRAWINGS AND SELECTION ELECTRICAL FIXTURES. THIS WAS A VERY CREATIVE PROJECT AND THE SCHEME WAS TO BE KEPT INTO CONSIDERATION WHILE DOING THE PROJECT.



ENVIRONMENTAL LIGHTING AND DESIGN THIS PROJECT WAS PART OF A LIGHTING SEMINAR DONE DURING MY UNDERGARD. THERE WERE A SERIES OF SEMINARS AND LECTURES ON ENVIRONMENTAL LIGHTING AND THE PROJECT CONCLUDED WITH EVERYONE DESIGNING AND EXECUTING THOSE DESIGNS BY MAKING A LAMP.





DESIGN OF INFORMAL SCHOOL IN JAISALMER,INDIA THIS WA S THE UNDERGRADUATE THESIS PROJECT, WHICH WAS EVIRONMENTAL FRIENDLY. COMLETLY DONE AND RENDERED ON REVIT, INCLUDING THE NIGH T VIEWS AND LIGHTING.




LIGHTING RENDERINGS DONE ON REVIT HERE ARE OTHER SAMPLE RENDERINGS DONE ON REVIT, BY USING DIFFERENT LIGHTING FIXTURES AND ADJUSTING THEIR LUX LEVELS.


Lighting rendering and illumination calculation done on revit and


LIGHTING DESIGN FOR A BAR

A LIGTING DESIGN PROJECT DONE FOR A BAR USING Agi 32 SOFTWARE AND REVIT


CONCEPT

The old Brewing Company Inc.


F1

F1

F5

F5

F3

F1

F1 F5 F3

F3

F5 F3

F1

F1 F5

F3

F5

F3

F3

F3

F3

F2 F4 F3 F2

F4

F4

F4

F4

F3

F4

F3 F1

F3 F5

F3

F1 F1

F6

F4

F2

F1

F5

F3

F6

CHANDLIER LIGHT 24” DIA 80 CRI 3000 K 96 watt 5700 net lumen

GLOBE LIGHT 2500 K AMB Amber 120 - 277 Volt Input 80+ CRI

SLIM COVE LIGHT 2700 K 77 CRI 3.5 With/ 12” length F2 WALL MOUNTED LIGHT Delta lighting 2200 K,

FILAMENT LED LIGHT 2200 K, CRI 60 3.5 Watt

HANGING LIGHT 3000 K 120 - 277 Volt Input 19


Illuminance (Fc) ) BAR (4’) Average=14.21 Maximum=18.7 Minimum=4.3 Avg/Min=3.30 Max/Min=4.35 FRONT BAR ( 3’) Average=21.94 Maximum=154 Minimum=9.2 Avg/Min=2.38 Max/Min=16.68 Left Bar_1 (2.5’) Average=12.44 Maximum=48.5 Minimum=8.3 Avg/Min=1.50 Max/Min=5.84

RIGHT BAR_2 (2.5’) Average=15.82 Maximum=152 Minimum=6.4 Avg/Min=2.47 Max/Min=23.67 HUMIDOR (1.5’) Average=63.91 Maximum=121 Minimum=26.1 Avg/Min=2.45 Max/Min=4.62 CORRIDOR (1’) Average=16.25 Maximum=89.5 Minimum=1.9 Avg/Min=8.55 Max/Min=47.11

BACK OF HOUSE (2.5’) Average=28.97 Maximum=117 Minimum=2.4 Avg/Min=12.07 Max/Min=48.63 RESTROOM (3.25’) Average=23.23 Maximum=115 Minimum=3.7 Avg/Min=6.28 Max/Min=31.05 20