BALJINDER KAUR
PORTFOLIO
TABLE OF CONTENTS _________________________ Collectors Club: Facade Restoration
4-5
145 Hicks Street: Interior Renovation
6-11
Gramercy Park: Interior Renovation
12-29
High Line Project
30-39
Abstract Modeling
40-41
FACADE RESTORATION
4
22 E35TH STREET NEW YORK 10016
FACADE RESTORATION
22 E35TH STREET NEW YORK 10016
5
INTERIOR RENOVATION
6
145 HICKS STREET BROOKLYN NY 11201
INTERIOR RENOVATION
145 HICKS STREET BROOKLYN NY 11201
TENANT SAEFTY PLAN
7
INTERIOR RENOVATION
145 HICKS STREET BROOKLYN NY 11201
DEMOLITION PLAN
8
INTERIOR RENOVATION
145 HICKS STREET BROOKLYN NY 11201
PROPOSED PLAN
9
INTERIOR RENOVATION
10
145 HICKS STREET BROOKLYN NY 11201
INTERIOR RENOVATION
145 HICKS STREET BROOKLYN NY 11201
11
INTERIOR RENOVATION
12
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
13
INTERIOR RENOVATION
14
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
15
INTERIOR RENOVATION
16
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
17
INTERIOR RENOVATION
18
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
19
INTERIOR RENOVATION
20
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
21
INTERIOR RENOVATION
22
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
23
INTERIOR RENOVATION
24
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
25
INTERIOR RENOVATION
26
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
27
INTERIOR RENOVATION
28
7 GRAMERCY PARK WEST NEW YORK 10003
INTERIOR RENOVATION
7 GRAMERCY PARK WEST NEW YORK 10003
29
HIGH LINE BUILDING PROJECT
NYCCT
LOCATION PLAN: Borough: MANHATTAN Block: 690 Lot:29 Police Precinct: 10 Owner: SOMATIC REALTY LLC Address: 131 10 Avenue Lot Area: 23000 sf Lot Frontage: 184' Lot Depth: 125 Year Built: Unknown Number of Buildings: 0 Number of Floors: 0 Gross Floor Area: 0 sf (estimated) Residential Units: 0 Total # of Units: 0 Land Use: Parking Facilities Zoning: C6-2 Commercial Overlay: Zoning Map #: 8B Dept. of City Planning, PLUTO 11v2 copyright 2011
TENANT SAFETY NOTES: 1. GENERAL A.
ALL WORK TO BE DONE IN ACCORDANCE WITH THE N.Y.C BUILDING CODE, ARTICLE 19, AND ALL OTHER AGENCIES HAVING JURISDICTION.
2. STRUCTURAL A. CONTRACTOR TO PROVICE ADEQUATE TEMPORARY BRACING AND SHORING WHENEVER STRUCTURAL WORK IS INVOLVED. B. ALL DEMOLITION OPERATIONS, REPAIR OPERATIONS, AND ALTERATIONS OPERATIONS TO BE DONE IN ACCORDANCE WITH N.Y.C.BUILDING CODE, ARTICLE 19, SUB-ARTICLES 1906.0 AND 1906.6. 3. MEANS OF EGRESS A. ALL MEANS OF EGRESS FROM THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING MATERIALS, TOOLS, ETC. 4. FIRE SAFETY A. B. C. D.
ALL BUILDING MATERIAL STORED AT CONSTRUCTION AREA, AND OR ANY AREA OF THE BUILDING ARE TO BE SECURED IN A LOCKED AREA, ACCESS TO SUCH AREA TO BE CONTROLLED BY OWNER AND/OR GENERAL CONTRACTOR. ALL MATERIAL TO BE STORED IN ORDERLY FASHION. ALL FLAMMABLE MATERIALS TO BE KEPT SEALED IN THEIR RESPECTIVE MANUFACTURERS CONTAINERS, SUCH MATERIAL TO BE KEPT AWAY FROM HEAT, AND STORED IN ADEQUATELY VENTILATED SPACE. CONTRACTOR TO SUBMIT A SCHEDULE OF ANY CUT-OFF FOR WATER, GAS, WATER OR ELECTRICAL SERVICES SHALL BE KEPT TO A MINIMUM.
5. DUST CONTROL A. DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM, AND TO BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. B. THE CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY PARTITIONS OR HEAVYWEIGHT DROP CLOTHS. C. DEBRIS, DUST AND DIRT TO BE CLEANED UP AND CLEARED FROM THE BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION. 6. NOISE AFTER HOURS A. WORK TO BE DONE DURING REGULAR HOURS ONLY, 8AM TO 5PM, EXCLUDING ALL WEEKENDS AND LEGAL HOLIDAYS.
ITEMS SUBJECT TO CONTROLLED INSPECTIONS 1. FIRE STOPS 2. HVAC VENTILATION SYSTEM FIRE DAMPERS 3. EQUIPMENT USE PERMITS 4. NOISE CONTROL FOR HVAC INSTALLATION 5. WELDING 6. HIGH STRENGTH 7. STRUCTURAL STABILITY 8. FINAL INSPECTION DIRECTIVE 14/75
30
HIGH LINE BUILDING PROJECT
NYCCT
SITE PLAN DIAGRAM
AXONOMETRIC DIAGRAM
LOCATION IMFORMATION Adress: 131 10 AVENUE NY 10011
Not To Scale
Lot Coverage 67% As Per ZR 93-42
Block: 690
Not To Scale
Required Setbacks Fornt: As Per ZR 93-512 Rear: As Per ZR 93-512 Side: As Per ZR 93-512
Lot: 29
Lot Area: 23,000 SF
40' Street Wall As Per ZR 93-512 178' Building Height As Per ZR 93-512
NORTH
LEGEND C6-2 Residential District Equivalent R8 Quality Housing Program Zoning Map: 8b Floor Area Ratio(FAR) Commerical FAR: 6.0 Residential FAR: 0.94-6.02 Proposed Area: 122,280 SF Allowed Area: 23,000 X 6.0 = 138,000 SF Allowed FAR: 6.0 Propsed FAR: 122,280/ 23,000= 5.32
W 19 ST 125'
Proposed Building
178'
Zoning Lot Line
Maximum Building Envelope
No Rear Yard As Per ZR 93-512
90'
184'
40' 10 AV
Wthin 10' As Per ZR 93-512
73'
32'-6"
SECTION DIAGRAM Not To Scale
No Side Yard As Per ZR 93-512 W 18 ST
178'
40' W 18 ST
W 19 ST
10 AV W 18 ST
31
HIGH LINE BUILDING PROJECT
NYCCT
ZONING ENVELOPE Not To Scale
138'
46'
178'
73' 40% 45' MAX
Tenth Avenue could rise to between 35 feet and 45 feet in height for 25% of its Tenth Avenue frontage. This lowered streetwall would be required to be located at a street intersection. The remaining 75% of the street wall could rise to the maximum allowable building height.
111' 60% 57'-6"
A maximum of 40% of a building’s High Line frontage would be permitted to rise to the maximum allowable building height directly adjacent to the High Line structure. The remaining 60% (minimum) of a building’s High Line frontage would be permitted to rise no higher than the level of the High Line before setting back a minimum of 25 feet. A minimum of 20% of the lot area would be required to be reserved as landscaped open space.
25' 32'-6" 25%
BUILDING ZONING
32
HIGH LINE BUILDING PROJECT
1 8
2 7
NYCCT
3 6
4 5
5 4
6 3
7 2
8 1
175' - 0"
2
A
3 3 3
001
3
2
UP
3
2
011
3
3
B
010 3 2 3
3
002
3
3
3
3
3
3
3
2
2
2 3
2
2
UP
009
Room B001
2
3
3 2 3 004
C
2 2 3
2 2
3 3
2 3 3
UP
3
3 2
003
005 3
3
2
3
3
006
D
3
Room
3
B002
3 007
3
Room
Room
B003
B004
008
Room 3
3
B005 3
E
3 3
SLAB CELLAR
1
2
3
4
5
6
7
8
175' - 0" 25' - 0"
25' - 0"
25' - 0"
25' - 0"
25' - 0"
25' - 0"
13' - 2"
A
B
22' - 0"
--DN UP DN 202
C
22' - 0"
UP DN
DN
D
201
2 A-601 22' - 0"
25' - 0"
E
1ST FL COMMERCIAL PLAN
33
HIGH LINE BUILDING PROJECT
1 8
2 7
NYCCT
3 6
4 5
5 4
6 3
7 2
8 1
175' - 0" 29' - 6"
25' - 0"
25' - 0"
25' - 0"
25' - 0"
25' - 0"
25' - 0"
A 5
Apartment
109
5 13' - 2"
Apartment
108 498
499
5
511 7/32
"
B 500
5' - 8
5 513
503
Studio
5
3 5
110
Studio 5
2
22' - 0"
5
UP
2
111
C
2 497
504
508
496
5 5
490
UP
2
495
107 2
2
488
486
5
101 487
Studio 102
5
492
2
512
484
Apartment
489
485
507
Apartment
509
Apartment
506
103
Apartment
Apartment
104
105
D
2
493
Apartment
2
106
491
22' - 0"
5
505
" 3/16
502
6' - 1
501 2
22' - 0"
2
5
494
510
2
2
E 5 5
5
5
5
3RD FL RESIDENTIAL PODIUM
1 8
2 7
3 6
4 5
5 4
6 3
7 2
8 1
A
B
C
D
E
34
4TH FL RESIDENTIAL PLAN TYPICAL
HIGH LINE BUILDING PROJECT 1 8
2 7
NYCCT
3 6
4 5
5 4
6 3
7 2
8 1
5 5
5
1206
Complex 4
PH05
Complex
A PH06
4
PH04
5 4
5 5
5
Complex
B
1205
1207
4
4
5 5
5
1201
C 1204
4 4 5
Complex
4
PH03
Pool 1203
PH01 5
4
D
1202
4
4
5
UP
5
Complex 5 5
PH02
E
5
PENTHOUSE PLAN 2 7
3 6
4 5
5 4
6 3
7 2
8 1
A
B
C
D
E
FURNITURE PLAN TYPICAL 35
HIGH LINE BUILDING PROJECT
NYCCT
Insulating Glass
Thermal Breaks
Horizontal Mullion Floor Cap 179' - 11 13/16" Firesafting
Infill Panel
Shelf Angle
Insulation
Hanger Wire
Runner Insulation
Gypsum Board
Base
Sealant 178' - 3 27/32"
Concrete Slab
L1-C1 0' - 0"
CURTAIN WALL DETAIL
COMMERCIAL 2HR WALL
Finish Floor
0' - 5 5/8"
0' - 2" 0' - 1 1/2" 0' - 3 5/8"
Vapor Paper
2 X 5/8" TYP Gypsum Boar 0' - 6"
Subfloor
1 1/2" Metal Furring 5 5/8" CMU 2" Rigid Insulation 1 1/2" Air Space
Concrete Floor Slab
3 5/8" Brick Face Rebar
Rigid Insulation
Bond Beam Block Flashing 3/8"Joint
Backer Rod and Sealant
Concrete Slab Rigid Insulation
Head
Fill Crushed Stone Drain Tile
Parging
Key
Footing
Sealant
Rowlock Sill
Flashing Sill
GROUND DETAIL
36
WINDOW DETAIL
HIGH LINE BUILDING PROJECT
NYCCT
0' - 0 5/8"
0' - 0 5/8"
0' - 5 5/8"
0' - 2"0' - 1 1/2" 0' - 3 5/8"
0' - 1 1/2"
2 X 5/8" TYP Gypsum Board
1 1/2" Metal Furring
2" Rigid Insulation
Barrier Paper
3/4"Finish Floor
Metal Wall Ties @ 16" O.C
Vapor Paper
1 1/2" Air Space
1" Subfloor 3 5/8" Brick Face Two-Way Flat Slab Baseboard Continuous Flashing
Reinforcement
Anchor
WINDOW DETAIL
0' - 6 1/4"
0' - 1"
0' - 0 3/4"
Rebar @6" O.C
Shelf Angle
Drip Edge
Sealant
5 5/8" CMU
Hanger Wire
RESIDENTIAL WALL/FLOOR DETAIL
37
HIGH LINE BUILDING PROJECT
NYCCT
3D VISUAL
38
HIGH LINE BUILDING PROJECT
NYCCT
39
ABSTRACT MODELING
The recess study is developed by paneling tools to create a surface along a path that include both smooth and sharp surfaces. It allows access and movement through directional spaces mounted on the surfaces with holes. 40
This shape constitutes a partition thats joins via curves through intersections. The curves bring life to the wall andcreate a sense of feeling of sensitivity from its puncture within itself.
ABSTRACT MODELING
41