GbR
bambach tensio-technik Inhalt
1 2 2 3 4 5 6 6 7 8 8 9 10 10 11 13 14 16 17 19
Inhalt Surface-Tensio Insertion-Tensio small Premium Insertion-Tensio Premium Insertion-Tensio - with exchangeable clay tip Insertion-Tensio Blumat Steck-Tensio Ceramic Steck-Tensio ‚massiv‘ Manometer M-Sensores (Switching Sensors) TensioSwitch (Switching Sensors) TensioTrans (Analogue Sensor) E-Sensors (Analogue Sensor) TensioMark (Analogue Sensor) Capacitive Sensors TensioAlarm (wireless module) SensorMatic 10 (switching module) TensioController (irrigation computer) TensioLogger INL (Internetlogger) Additional Accessories
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Surface-Tensio
www.tensio.de
Surface-Tensio Surface-tensiometers are suitable for use as tensiostats for controlling irrigation when used together with a switching sensor. This option comes into consideration for capillary matting with drip irrigation, controlled flow or thin layer cultivation with drip irrigation. In combination with a sensor or manometer, surface-tensiometers, can be used solely for moisture measurement on irrigation or technical fleece, on a substrate surface or in a substrate. Surfaces-tensiometers of this design are suited only briefly for suction pressure above ca. 300 hPa; otherwise frequent refilling is necessary.
1110-IT90
Clay base- Ø ca. 70 mm, top surface sealed with a robust shrink wrap (Model FV) or with a porous surface (Model FO), heightavailable from 65 mm (GL connection) up to 110 mm (IT45 connection), without viewing window Connections: GL = Standard GL 14 threaded neck, IT = here with integrated T-piece connection of 45° or 90° with 2x GL 14 threading
Article number
1100-GL
Typ
GL
IT90
IT45
FO FV
1100-GL 1110-GL
1100-IT 90 1110-IT 90
1100-IT 45 1110-IT 45
Tip for ordering- all tensiometers consist of a two part construction: below is a tensiometer and above a manometer or sensor. The parts can be combined variably and must be chosen to fit together.
1205
1202
Small insertion-tensiometers can be distinguished by the two different sized clay tips: either Model KVO.. with a 10 mm Ø tip for the smallest containers (for pots of ca. 5 cm or more) or the Model KV.. series with a 15 mm Ø for standard pots (KV2) up to midsize containers or shallow rooted bed plantings (KV3). The maximum suction pressure by the smaller models is limited to 200 hPa due to its design and corresponding smaller water volume. In certain cases, it is advisable to use a capillary tube extension. Small insertion-tensiometers are often used as tensiostats with switching sensors for watering purposes. However, it is often combined with electronic sensors for control purposes or even just for recording moisture trends. Using a T-piece joint, it is possible to add manometers, for example, in order to control switching points.
1201
Insertion-Tensio small
It is generally not necessary to correct for the water column in these small tensiometers.
2
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Premium Insertion-Tensio
www.tensio.de
Article number
Model KV01 KV02 KV1 KV2 KV3
GL 1201 1202 1205 1206-GL 1210-GL
BL 1206-BL -
1210-GL
1206-BL
Model KV01: length-8.5 cm, tube- Ø 15 mm, shrink-wrapped, without viewing window, clay tip- Ø 10x30 mm, use only with capillary tube extension; Model KV02: length- 12.5 cm, tube- Ø 15 mm, shrink-wrapped, with viewing window, clay tip- Ø 10x30 mm, limited volume, max. ca. 200 hPa; Model KV1: length- 12 cm, tube- Ø 18 mm, shrink-wrapped, without viewing window, clay tip- Ø 15x40 mm, limited volume, max. ca. 200 hPa, preferably for use with capillary tube extension; Model KV2: length ca. 16 cm (15 cm- BL), length with IT ca. 19 cm, tube- Ø 18 mm, shrink-wrapped, with viewing window, clay tip- Ø 15x40 mm; Model KV3: length- 21.5 cm (GL), length with IT ca. 25 cm, tube- Ø 20 mm, shrink wrapped, with viewing window, clay tip- Ø 15x40 mm. Connections: GL = Standard GL 14 threaded neck, BL= threading for digital manometer, IT = here with integrated T-piece connection of 45° with 2x GL 14 threading, BL + GL can be combined as option
1206-GL
Insertion-Tensio small
IT45 1206-IT45 1210-IT45
1230-24 + 1721
A unique feature of the newly designed series of premium tensiometers Model LM … is the large volume, robust tube and the sturdy, cylindrical clay tip. In addition to mechanical stability, the series has the advantage of having a longer use time (less maintenance) due to its larger capacity. Premium Insertion Tensiometers are suitable, in combination with a manometer or electronic sensor, for soil measurement in all desired depths of more than ca. 15 cm insertion depth. Tensiometer tubes generally project above the ground 8-10 cm. It is advisable to plan the total length correspondingly in order to avoid any unnecessary temperature influences caused by overly long, projecting tubes. With its various connection possibilities, the Model LM is suitable for use with switching sensors for controlling watering, as well as for on-site control when combined with a digital manometer.
1230-24
Premium Insertion-Tensio
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
3
Premium Insertion-Tensio - with exchangeable clay tip -
www.tensio.de
Premium Insertion-Tensio Acrylic glass tube- Ø 25x3 mm, clay tip- cylindrical with tapered end, Ø 20x65 mm, tube fully shrink-wrapped, with a viewing window (ca. 6 cm), viewing window ca. 3 cm by a total length of 24 cm. Connections: BL= threading for Blumat digital manometer, GL = Standard GL 14 threaded neck for sensors and mechanical manometers, IT = here with integrated T-piece connection of 45° with GL + BL for combining with switching sensors and digital manometers.
Article number
Model LM-BL LM-GL LM-IT
Total length in cm (for IT connection + 3 cm) 24 34 44 54 1230-24 1230-34 1230-44 1230-54 1232-24 1232-34 1232-44 1232-54 1234-24 1234-34 1234-44 1234-54
1234-24
1232-24
Note to length of insertion-tensiometers: the tensiometers tube projects above the ground only about 8-10 cm for control purposes, therefore, the maximum insertion depth (measuring depth) is correspondingly less than the total length given (does not apply to the small tensiometers).
64 1230-64 1232-64 1234-64
84 1230-84 1232-84 1234-84
94 1230-94 1232-94 1234-94
Premium Insertion-Tensio - with exchangeable clay tip Unlike the Model LM, the premium Insertion-Tensio Model LW has an exchangeable clay tip, which has a screw-neck on top for screwing into an axial o-ring gasket. This makes for a reliable seal, however, special care must be taken to only turn the tensiometer to the right when inserting or removing it from the soil. The advantage of the exchangeable clay tip is its easy replacement in case of damage, and also the possibility of varying the insertion depth by using the premium tip with tensiometer tubes of different lengths (tubes without a tensiometer tip).
Series LW-...
Acrylic glass tube- Ø 25x3 mm, clay tip- cylindrical with tapered end, Ø 20x65 mm, tube fully shrink-wrapped, with a viewing window of ca. 6 cm. Connections (top): BL= threading for Blumat digital manometer, GL = Standard GL 14 threaded neck for sensors and mechanical manometers, IT = here with integrated T-piece connection of 45° with GL + BL for combining with switching sensors and digital manometers. Connections (bottom): tube with integrated GL 14 threading + O-ring gasket, clay tip with GL 14 connection.
4
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Insertion-Tensio Blumat
www.tensio.de
Premium Insertion-Tensio - with exchangeable clay tip -
Article number
Model LW-BL LW-GL
Total length in cm (for IT connection + 3 cm) 27 37 47 57 1230-27 1230-37 1230-47 1230-57 1232-27 1232-37 1232-47 1232-57
67 1230-67 1232-67
87 1230-87 1232-87
97 1230-97 1232-97
Insertion-Tensio Blumat
Article number
Model BL
1720
BD1
Total length in cm 23 1240-23
33 1240-33
43 1240-43
1720
Acrylic glass tube- Ø 20x3 mm, Blumat clay tip, cylindrical with tapered end, max. Ø 22x55 mm; Connection: BL = threading for digital manometer.
1240-23
The insertion-tensiometer „Blumat“ Model BL is designed to be a reasonably priced, light weight sensor, planned for use together with a digital manometer. The design is based on a slim 18 mm tube and uses a conical clay tip from the Blumat series of the corresponding size (not extra type tested). In contrast to the original “Blumat Digital” Model BD 1, the Insertion-Tensio Blumat is designed for professional use with a transparent tube and can be used in greater depths. The insertion-tensiometer Blumat, together with a digital manometer, presents a dependable moisture measuring device for all measuring needs in standard depths for not overly dry locations. In order to avoid temperature influences while measuring, it is advisable to plan the total length of the tensiometer to fit the measuring depth and thereby avoid overly long tubes projecting above the ground.
53 1240-53
Soil moisture sensor Blumat Digital (original model), including transparent plastic tube and measuring head, length 22 cm
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
5
Steck-Tensio Ceramic
www.tensio.de
Steck-Tensio Ceramic The special feature of the insertion-tensiometer “Ceramic”, of the Model LK-series, is the unique ceramic tip K100 (comparable to the tip type P80). The basis for this end piece is mulliteceramic, a high quality silicate, which surrounds an inert, lowsorption chamber. Suitable for all soil measurements with tensiometers, used especially for scientific purposes and there where similar types of tensiometers are in place, for example, the P80 tip. Due to the unique properties of the end piece, the bottom part can be used as a suction-tensiometer, suitable for suctioning moisture from soil when combined with the set “Suction-Tensio” with capillary tubing and collection vessel (available upon request), especially recommended when heavy metals are a factor.
Article number
Model LK-GL
1252-22
Acrylic glass tube- Ø 20x3 mm, rounded ceramic tip-K100 (similar to P80), Ø 20x50 mm, tube fully shrink-wrapped, with a viewing window (ca. 6 cm) Connections: GL = Standard GL 14 threaded neck for sensors and mechanical manometers Total length in cm 22 32 42 52 62 1252-22 1252-32 1252-42 1252-52 1252-62
Steck-Tensio ‚massive‘
1264-35
Acrylic glass tube- Ø 30x4 mm, rounded clay tip- Ø 30x75 mm, nominal height marking on the tube (=insertion depth).
1262-35
The tensiometer Model M… convinces with its high capacity, large volume design, with its robust 30 mm tube. A special feature of the series is the large volume clay cone with a corresponding large reaction surface. Suitable for all measuring situations, it is especially well suited for dry locations with hPa values often in the upper range. The large capacity requires refilling much less frequently.
Connections: GL = Standard GL 14 threaded neck for sensors and mechanical manometers, IT = here with integrated T-piece connection of 45° with GL + BL for combining with switching sensors and digital manometers.
Article number
6
Model M-GL M-IT
Total length in cm 35 45 1262-35 1262-45 1264-35 1264-45
(IT connection length + 3 cm) 55 65 85 1262-55 1262-65 1262-85 1264-55 1264-65 1264-85
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Manometer
www.tensio.de
Manometer Analogue, mechanical manometer The classic tensiometer is made up of two parts: below a tensiometer and above a manometer. The manometer is a pressure gauge which shows the suction tension on the tensiometer directly, without any preparation. The instruments are maintenance free and long lasting, when handled carefully. The measuring element is a capsule pressure gauge, which has an overload capacity of up to -1 bar (1000 hPa). The accuracy is generally 2.5% of the measuring range. The manometers are individually calibrated and the deviation is noted on the test certificate. Settings are adjustable. These special manometers can be used for all tensiometer measuring needs. Together with switching sensors (+ T-connectors), they can be used for control measuring or for evaluating the settings of the switching points. However, please note that for direct switching tensiostats, the reaction time for the manometer to turn off is somewhat slower.
1705
1707
Digital Manometer The digital manometer is made up of a piezoresistive pressure gauge (comparable to electronic-sensors) and a battery powered display. The instrument is activated with an on/off button. Otherwise, the use corresponds to that of the mechanical manometer. It is also possible to use the digital manometer in conjunction with switching sensors (M-sensor or TSW) via a Tconnector. The manometer is maintenance free, and should be operated in the range from -5° to +40°C. The replaceable lithium battery (CR 2032) has a life of 30,000 cycles. Connection for Model M: screw on cap with GL 14 female threading Connection for Model BD: Blumat threading (21 mm), both with plastic casing
Article
Model
1705
M 400
1707
M 600
1721
BD2
1721
0-400 hPa, ±5-(10) hPa, calibrated, readable in intervals of 5 hPa, zero point adjustable, overloadable 0-600 hPa, ± 5-(15) hPa, calibrated, readable in 10 hPa intervals, zero point adjustable, overloadable Digital manometer, 0-750 hPa, resolution/display unit 10 hPa, display duration- 10 sec., includes zero point reset
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
7
M-Sensores (Switching Sensors)
www.tensio.de
M-Sensores (Switching Sensors) “M-sensors” are sub-pressure electro-mechanical (vacuum) switches. With an M-sensor, it is possible to upgrade a tensiometer bottom to a “tensiostat” with switching capabilities. These sub-pressure sensors are membrane switches typically used for low voltage (such as 24 V) for defined switching ranges, and have no specific protection against moisture. The switching points are continuously adjustable, however, without a scale; a typical switching point is marked. For automatic watering, M-sensors are generally connected to an automatic watering system. (The sensor switches on, the system switches off.) Direct switching is also possible via a 24 V transformer; in this case, the tensiostat switches on and off. The length of watering required should be seen independently of the suction tension. When used outdoors, M-sensors must be carefully protected from moisture (see our new protective housing), otherwise, the lifespan of the sensor will be shortened. Mechanical, potential free membrane switch (passive) for NO switching (shut-off) or NC (opener) infinitely variable adjustment, without scale, calibrated, typical (average) value marked, switching differential ca. 15-20% of the end value; connections: electrical flat-pin plug socket of 6.3 mm for tensiometer screw cap GL 14; delivered with protective cap (IP 44= protection only against splashing water).
Article number
Model MS
1515
S-MS
1515
1510-.....
1510-....
Lowest switching sensitivity in hPa (maximum) 10 (50) 50 (125) 100 (300) 200 (500) 300 (700) 1510-10 1510-50 1510-100 1510-200 1510-300 Protective housing for MS with O- ring gasket + pressure compensator (aeration), IP 65, with screw on cables, recommended for avoiding corrosion when used outdoors.
TensioSwitch (Switching Sensors) TensioSwitch (TSW) and TensioTrans (TT) - see below- are electronic sensors for tensiometers using a new technology of the same design, however, with different sensor outputs. With the switching output function of the TSW, the tensiometer becomes a complete and independent “tensiostat” and, therefore, is an alternative to the M-Sensor. The advantage of the TSW lies in the hands-free switching feature. When negative pressure is increasing, the electrical switching function is referred to as a “switchable connection to ground” (npn). A red LED lights up when the switch is in the “on” position. The switching point is adjustable between about -25 to -400 hPa by means of a continuously variable adjusting screw; the switching differential remains a constant 7-10 hPa. TensioTrans has an analogue output sends a signal of 0-10 V. The tensiometer is outfitted to receive constant electronic readings; these signals must be further processed by a digital device.
8
The measuring range is for 1000 hPa with an accuracy level of 1 %. TT is an alternative to “E-Sensors”. The new technology behind both sensors is the so-called “Hall Effect”. The suction tension of the tensiometer (negative pressure) is detected by a low-pressure capsule gauge and relayed over a magnet to the switching electronics. Both kinds of sensors require an electrical supply of 10-30 V DC (direct current from mains) to power the electronics. A standard circular plug for sensors serves as the electrical connection. The black lacquered brass housing is especially durable and is protected against splashing water. The protective cap pro-
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
TensioTrans (Analogue Sensor)
www.tensio.de
TensioSwitch (Switching Sensors)) vides a further safeguard. For watering purposes, the TSW can either directly switch a 12 or 24 V DC solenoid valve (Tensiostat switches on and off) or it can control a pump over its own relay. A direct connection to certain automatic watering systems is possible (Tensiostat switches on, watering system off). Otherwise, the connection can be made via a small relay (Model KR 12) in the junction box. The TT is usually connected to a data-logger, for example, the Tensio-Logger, or to a climate computer with a watering module as well as to the TensioController. It is used for recording the moisture gradient or for controlling and monitoring the watering operations.
Article
Model
TSW 400 1520 ST5
1522
KR 12
1807
Description TensioSwitch, switching points continuously adjustable from 0-400 hPa (above ca. 25 hPa), factory set at 100 hPa. Connection for TSW + TT, angular, round sensor plug M 12x1, shielded, 7 m long moulded cable connector. Junction box with small relay for TSW, 85x85x40 mm, with aligned terminal clamps + mini-relays (12 V DC), potential-free, switching load- 20 A, NO (off)/ NC (on) switching.
1721 1234-...
Electronic switch (hands-free) as ground switch (npn), NO switching type- (shut-off), switching differential remains a constant 7-10 hPa, switching state displayed with LEDs, 10-30V DC power supply, pressure measurement with a bourdon pressure gauge, black varnished brass housing (IP65), Ø- ca. 37 mm, height ca. 71 mm, weight 110 g, electrical connection with sensor plug M 12x1, 3-wired cable, connection for tensiometers with screw-on cap, includes help for adjusting.
1520 + 1522
1807
1531 + 1522
TensioTrans (Analogue Sensor) Electronic pressure gauge for tensiometers, comparable to Esensors, designed like the TensioSwitch (see above), however, with analogue output (also see E-sensors). Article TT
Model 1531
Description TensioTrans, measuring range 0-1000 hPa, signal 0-10 V, power supply 10-30 V DC.
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
9
E-Sensors (Analogue Sensor)
www.tensio.de
E-sensors are electronic pressure gauges, which act as “analogue sensors” to continuously measure the suction pressure of the tensiometer. The measurement signals are further processed in the digital unit for either display or switching purposes. The device consists of a piezo-resistent pressure sensor for differential measurement of pressure with an additional measurement converter for each type of signal; the unit can be ordered optionally without the converter function; the accuracy of measurement is, in general, 0.5 %. The plastic housing is ventilated and has a white protective covering. The electronics are additionally protected by an insolating moulding, the unit can be factory calibrated and repaired. The sensors are resistant to disturbance according to CE norms and have an inverse-polarity protection. A permanent cable socket is provided for electrical connection. In order to have continuous moisture measurement and to observe the course of moisture levels over time, a connection must be made to a PC, climate computer or data logger with an input corresponding to the signal (also see TensioLogger and TensioController). In this case, the power supply usually comes from an external mains connection.
1610-... + 1110
1610-....
E-Sensors (Analogue Sensor)
Types of signals: Model ES-C: 4-20 mA sign., 14-26 V DC; Model ES-CV: without measurement converter, proportional signal by 12 V DC, ref. -350 hPa = 60 mV sign., 1000 hPa = 90 V sign.; Model ES-CVR: 0.1-2.5 V, 4-15 V DC; general accuracy of 0.5 %, plastic housing with protective covering, Ø- 26 mm, height- ca. 70 mm, weight- ca. 27 g, electrical connections with 5 m long solid cable, wiring- 2-4 strands, all connections made for Tensiometer screw-on caps (GL 14).
Article number
Model ES-C ES-CV ES-CVR
Measuring range (0 ...) with max. pressure in hPa 350 500 1000 1600-350 1600-500 1600-1000 1606-350 — 1606-1000 1610-350 Upon request 1610-1000
TensioMark (Analogue Sensor) TensioMark is a new electronic, maintenance-free soil moisture sensor that directly determines the suction tension of the soil (matrix potential) in defined intervals and transmits either analogue or digital measurement signals. The sensor is similar to a tensiometer, however, requires no water column, making it suitable for year-long measuring. The measuring principle is based on the direct correlation of the thermal capacity of a substrate to a specific moisture level. By means of short pulses of heat within an equilibrium body, the thermal capacity of a constant, defined reference substrate can be determined and, using these known values, correlated to the suction tension of the soil. This value represents the availability of water in the soil. The equilibrium body, in this case, a highly porous, tensi-
10
ometer-like chamber, stands in a constant, fast reacting exchange with the surrounding soil. Due to the indirect measurement in an equilibrium chamber, the soil type and density, as well as salinity have no affect on the results. Temperature also has no influence, because it is offset in the measuring process. TensioMark is produced as an insertion sensor in tube form; the relevant electronics are located in the head of the tube. The length of the tube corresponds to the insertion depth desired. The electrical connection uses a 4-pole socket.
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Capacitive Sensors
www.tensio.de
The standard model with an analogue signal of 0-10 V is connected to a data-logger, for example, TensioLogger, or a climate computer, for continuous moisture measurement. With a constant power supply, measurements are made every 15 minutes. TensioMark works together with the TensioLogger INL, as well as the digital signal for SDI 12 protocol; at the same time, the sensor delivers soil temperature values. Analogue signals are required for use with the switching units “SensorMatic 10” or “TensioController” for controlling watering. The special advantage of the TensioMark is its maintenance free, easy operation for long term use with dependable suction tension measurement. The results are comparable to those of a tensiometer, without requiring a water column for measuring purposes! The set-up follows the same rules as for tensiometers.
1621-R25
TensioMark (Analogue Sensor)
Power supply: 9-12 V DC, analogue signal: 0-10 V or SDI 12, measuring range: 1=1000, 2=2000, 3=3000 hPa; Design: tube sensor for underground use (RU), tube Ø: 25 mm, completely shrink-wrapped, length: 15 cm, connector + 3 m special capillary cabling; Tube sensor: Ø 25 mm, completely shrink-wrapped, connector + 3m connecting cable, 3x0.14 mm²; Cable Mini-Sensor (KM): (cable between tip of sensor and electronic housing), sensor tip: Ø 10/15 mm, connector + 3 m connecting cable 3x0.14 mm².
1621-KM7
1621-R10
Article number
Model TM 1 TM 2 TM 3
1625
TDM
Max. insertion depth of Model in cm RU R 10 R 25 R 45 R 65 KM 7 1621-RU 1621-R10 1621-R25 1621-R45 1621-R65 1621-KM7 1622-RU 1622-R10 1622-R25 1622-R45 1622-R65 1622-KM7 1623-RU 1623-R10 1623-R25 1623-R45 1623-R65 1623-KM7 Unit for displaying measurements from TensioMark, consists of measuring unit with LCD display (multimeter) + connections box for battery power supply of the TensioMark
Capacitive Sensors These sensors measure the absolute water content in a given soil volume. This is a “volumetric” measurement and is not comparable to the “water availability” based measurement of tensiometers. The measured results are expressed in % water volume (m³) per m³ soil; prerequisite is that the values can be digitally displayed over a measuring unit or PC and that a calibration curve for the specific soil type is available. The results are dependent on the soil type and can not be compared with results from other locations. Also, the salinity of the soil should not be too high (< 8 dS/m), however, the sensors will give an indication of differing sensitivity to salt. “Capacitance”
measurement is based upon the dielectrical characteristic of the soil for which various measuring techniques can be applied. The following examples function as FDR-sensors, in which high frequency electromagnetic waves react to varying soil moisture levels. It is important that the sensors are carefully installed in the soil, since cavities around the measuring electrodes disturb the waves. The advantage of capacitance sensors- as
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
11
Capacitive Sensors
www.tensio.de
Capacitive Sensors a rule, they are maintenance free and are suitable as analogue sensors for controlling watering, since, in this case, only the relative change in the moisture level is of importance and not the comparison to other soil types. Additionally, using the method of capacitance measurement plus the corresponding calibration curve allows the soil to be judged directly as to the useable moisture capacity of the field, and, therefore, to the amount of water which needs to be irrigated. Soil Moisture Sensor VH 400 Manufactured by Vegetronix Power supply: 3.5 – 20 V DC, signal: 3-0 V (100-0 % water volume) Signal range for useable moisture levels for potted plants (peat substrates): ca. 2.6 – 1.5 V Design: an electrode in rule form, 94x7 mm, with housing of ca. 40 x 23 x 13 mm. Special advantages: maintenance free and easy to use, low price, quick reacting, completely insensitive to salinity. Use: control of automatic watering systems, especially for not overly coarse substrates in container plantings, also suitable for higher water volumes. Connection to data logger (TensioLogger INL), SensorMatic 10 or TensioController possible.
VH 400
10 HS
Soil Moisture Sensor 10HS Manufactured by Decagon (from the ECH2O series) Power supply: 3-15 V DC, signal: 1.2 - 0.3 V Measuring range: 57 – 0 % water volume (definition 0.1 % by mineral soils) Design: 2 electrodes, length: 10 cm, total length: ca. 15 cm, width: ca. 3 cm Use: good measuring results for field use, suitable for ranges that are not overly moist, especially recommended for use with the handheld read-out unit, as well as for connection to a data logger (TensioLogger INL or the data logger from Decagon, when requested) or SensorMatic 10.
12
Article
Model
1640
VH 400
1642
10 HS
1650
EC-HH
EC-HH
Description Soil moisture sensor VH 400 as analogue sensor for control purposes, signal 3-0 V, ready to use with 5 m of cable Soil moisture sensor 10 HS as analogue sensor, signal 1.2 – 0.3 V, recommended for manual read-out, ready to use with 5 m of cable Handheld read-out device for the soil moisture sensor 10HS with corresponding calibration for mineral soils, digital display in Vol. %, no memory function
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
TensioAlarm (wireless module)
www.tensio.de
TensioAlarm (wireless module)
Transmitter (manufactured by Scout, Coniugo) with a MotorolaGSM-Module + SIM card + mini-antenna, with 4 inputs for 4 SMS capable telephone numbers, set via SIM card; additional electronics from Tensio-Technik for controlling sensor technology. Steps: The sensor measures the soil moisture and at the desired moisture level triggers a contact switch, or alternatively, the switching process is initiated by the additional electronics; the transmitter is hereby turned on for 2 min. in which time the SMS is sent. The SMS receiver must now start the watering! Reminders will be sent or the module can be placed on standby. Power supply: integrated battery pack fastened in the lid, 9 V (6x1.5 AA). Sensor inputs: Model TA-M- 1 or 2 digital switching sensors inputs with NO switching function (normally open, switch closes) or Model TA-A- 1 or 2 analogue sensor inputs with 0-10 V signals (also, as alternative, 0-3 V); max. 2 temperature sensors (silicon sensors KTY) can be added to both models, these will be automatically recognized by unit. Setting: The switching point for switching sensors is set externally on the sensor and is registered every 5 sec. On analogue moisture sensors, a threshold value and the thereby resulting switching points are set internally using two screw contacts with 15 steps (each step=50 hPa); temperature sensors are likewise set using 15 steps of 0-30°C. The sensors can be read-out in 4
Article
Model
1570
TA-M
1571
TA-A
1510-... + 1515
1232-24
TensioAlarm is a special battery powered, wireless module that sends a message via SMS after receiving a signal from soil moisture sensors, alerting the user to start the watering process. The desired moisture level at which watering should begin can be set using 2 sensors; additionally, the soil temperature can be monitored with 1-2 temperature sensors. TensioAlarm makes it possible to start watering in time and need based, making it especially useful for non-automatic systems. It also is suitable for use as an additional, independent monitoring unit for controlling automatic systems, for example, in combination with the switching module “SensorMatic 10” or the control unit “TensioController”.
1570
different intervals of 0.5, 2, 6, or 24 hours; a warning alarm can be sent either by the individual sensor or as a group, both options set with a sliding switch. The SMS reminder is sent in predefined intervals of 1, 3 or 24 hours, the batteries are controlled daily and a SMS warning is sent went weak. Equipment: grey plastic housing, 130x130x75 mm, + screw-on cable connections, IP 65, integrated battery pack in lid, optionally with lithium batteries.
Description TensioAlarm for connecting 1-2 switching sensors + 1-2 temperature sensors, includes 6 batteries; sensors not included, SIM card not included. Recommended sensor: M-sensor 100-300 hPa or 200-500 hPa + Insertion-Tensio of length desired TensioAlarm for connecting 1-2 analogue sensors with 0-10 V signal + 1-2 temperature sensors; includes 6 batteries, sensors and SIM card not included. Recommended sensor: TensioMark 0-1000 hPa.
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
13
SensorMatic 10 (switching module)
www.tensio.de
SensorMatic 10 (switching module)
Power supply: standard 9 V DC, 6 x 1.5 V AA batteries, optionally with external battery up to 12 V or external mains connection 15-25 V DC, (for example, with a connecting plug), optional configuration for 12-27 V AC. Operates in 5 sec. intervals, in between, device is on standby. Sensor input: 1-2 sensors with 0-10 V signals for TensioTrans or TensioMark, or 0-3 V for Sensor VH 400, or 0-1.2 V for HS 10; also possible, potential free switching input for M-Sensors as well as the switching signals from TensioSwitch. The sensors are powered over the SensorMatic at the time of sensor query; the query takes place for analogue sensors in 120 min. intervals, for switching sensors the cycle is every 5 sec. Sensor output: standard 9 V latching solenoid valve (for battery operation only), alternatively, with a standard solenoid valve with 24 V DC (closed system without current, monostable, powered only during the watering cycle) or also as a potential free switching output (max. load 200 mA) with NO (closer) or NC (opener) switching functions. Setting: duration of watering adjustable in 15 steps (1-30 min + ∞); moisture levels in 15 switching thresholds (applicable for both sensors) corresponding to the individual sensor elements and the relevant moisture level for the desired application; each setting adjustable using rotary switch. Programs for switching on and off: “Set Time”: sensor switches on, after set time switches off; “Max. Time”: sensor switches on and off, however, at the latest, after the set time has been reached (maximum time), “Pulse”: watering is divided over several cycles (set time + same amount of time as pause in watering), continues until sensor stops; set using a sliding switching. In addition, there is the possibility, independent of the program, to set manually, as well as an option for setting a cut-off time.
1510-... + 1515
1232-24
SensorMatic 10 is a sensor controlled switching module used as a 1 channel time relay for controlling watering with soil moisture sensors as the starter. SensorMatic 10 is designed as a watering control especially for professional demands in greenhouses or field use, as well as in gardens, indoor plantings and the watering needs of other small layouts. A unique feature is the combination variability, which allows for sensors with analogue signals as well as for switching signals, also there is a choice between mains power or battery power, and the possibility of switching output for various solenoid valves. In addition, all settings can be performed mechanically, without a PC. The unit is pre-configured as desired, in order to meet individual needs.
SensorMatic Model AP
SensorMatic Model CP
Control functions: includes monitoring of switching thresholds, sensor error control (unplug sensor), values above or below measuring range (too dry or too wet), as well as battery strength, optional LED display for each dysfunction message,
14
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
SensorMatic 10 (switching module)
www.tensio.de
SensorMatic 10 (switching module) in certain cases, watering stop function; push-button control function. Additional functions: standard model includes push-button check of current moisture level for external measuring and a locking mechanism to avoid more than one unit watering at the same time. Other helpful user specific functions including control over a floating switching in case of water back-up, a pulse counter or the relaying of error messages to a SMS-module can be added as part of an optional configuration (see Extra User Functions).
Article
Model
1550.
SM-AP
1552.
SM-AM
1554.
SM-BP
1556.
SM-BM
1558.
SM-CP
1560.
SM-CM
Configuration (standard version): grey plastic housing- 130 x 130 x 75 mm, + cable connectors, IP 65, hinged lid with integrated battery pack and LED display.
Description SensorMatic 10 for 9 V latching solenoid valve and battery operation, controlled via external switching sensors- M-Sensor or TSW ( setting on sensor), input not for analogue sensors SensorMatic 10 as described under 1550, however, for a normal (standard) solenoid valve with 24 V DC + external mains connection SensorMatic 10 for 9 V latching solenoid valve and battery operation, controlled via the analogue sensors, TensioTrans or TensioMark (0-10 V), input can be changed for switching sensors SensorMatic 10 as described under 1554, however, for a normal solenoid valve with 24 V DC + external mains connection SensorMatic 10 for 9 V latching solenoid valve and battery operation, controlled via capacitance analogue sensors with reflected measuring range (max. value = wet) SensorMatic 10 as described under 1558, however, for a normal solenoid with 24 V DC + external mains connection
Sensor Type 1550.1 1550.2
for M-Sensor for TensioSwitch
1552.1 1552.2
for M-Sensor for TensioSwitch
1554.1 1554.2
for Tensio-Trans for TensioMark
1556.1 1556.2
for Tensio-Trans for TensioMark
1558.1 1558.2
for HS10 (1,2-0 V) for VH400 (3-0 V)
1560.1 1560.2
for HS10 (1,2-0 V) for VH400 (3-0 V)
Extra User Functions* Nr. 1 2 3 4 5 6 7 8 9
Model -AC -counter
Description External mains connection 12-27 V AC (alternating current) Pulse counter, registers the number of watering sequences 2nd switching output (24 V) for control of pump or other instrument, in -pump planning stage -start Potential free switching output as external starter for automats -SMS Activation of external GSM-module (SMS warning) -floater Input for floating switch- for limiting water flow in case of back-up Customized cut-off times (user defined), standard: 4 h off, 5 h on, 5 h off -lock 10 h on Customized sensor query intervals (user defined), standard: 120 min., also -Interval available: 240 min. for Model SM-BP Customized length of watering (user defined), -time standard: 1,2,3,4,5,6,8,10,12,14,16,18,20,30, ∞ * Combining and assembling of different extra user functions only after consultation
Only for sensor type… ..M (standard-valve) ..M (standard-valve) ..M (standard-valve) ..M (standard-valve)
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
15
TensioController (irrigation computer)
www.tensio.de
TensioController (irrigation computer) Independent watering computer based on PLC (Programmable Logic Control), made by Fatek, modular design for universal use with automatic watering systems either in greenhouse or field applications (dependent on the power supply), especially suited for use with various analogue sensors, also, for use exclusively for timed watering. Special advantages: diverse configuration possibilities according to operational needs; clear and simple operation with customized software, supplemental parts, and exchangeable modules; non-standard programming is possible. Components: CPU for operations with relay outputs for valves (each unit requires 1 CPU), module for analogue sensors, touchscreen control possible when a PC is not in use, supplemental modules for valves; operates with 24 V DC on mains or solar power; outputs for solenoid valves (relays)- monostable, 12-24 V DC or AC (additional mains connector required, if necessary), includes outputs for pumps or warning module, also includes digital inputs for counting procedures (flow volume, precipitation) or switching sensors (Tensiometer, rain sensor). Configuration: diverse combinations of possible modules, which can later be expanded or replaced with other modules. For example: Smallest unit: CPU with 4 outputs for valves + input module for 4 analogue sensors. Largest unit: CPU + 14 modules with 160 outputs for valves and 20 analogue moisture sensors +additional connections (i.e. pump controller), in special cases, up to 250 outputs for connecting valves. Operation: via touchscreen, available in various sizes, standard size- 3.5” (9 cm), located in housing together with modules for basic control purposes or can be located in separate housing allowing for on-site use (with cable connection, max. distance100 m). Direct operation via laptop or netbook connection on housing (USB-connection) is an optional possibility. Optional remote control from a normal office PC is possible over a bus connection (RS485) or network connection (Ethernet) using the appropriate transmission software for the monitor. Assembly: one or two part plastic housing (polycarbonate, grey), for example, 30x30 cm or 30x45 cm, + extras to fit the number of modules in use, with hinged lid, with a corresponding number of terminals (mounted on rail system); housing protection level- IP 65, also suitable for use outdoors. Control variables: watering can be controlled using the following factors, dependent upon the number and kinds of sensors available for use independently or in combination time, soil moisture level, solar radiation, or humidity. Soil moisture sensors can be tensiometers with E-Sensors (4-20 mA) or TensioTrans (0-10 V), also the maintenance-free TensioMark (0-10 V) and the VH400 (0-3 V) are possible; solar radiation sensors: 4-20 mA or 0-10 V for 0-1500 W/m², humidity sensors: 4-20 mA for 0-100%. Software: groupings of sensors and valves in 20 (up to 30) sectors, each with I or more sensor probes + max. 8 valves + pump controller (or main valve), allocated as desired. When more than one probe per sector is in use, the result will be the
16
Assembly in metal board
Assembly for 12 solenoid valves and 6 sensors in plastic housing with touch screen 3,5 inch as a sample
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
TensioLogger INL (Internetlogger)
www.tensio.de
TensioController averaged value. Valves and sectors can be operated serially or parallel, watering operates according to pre-set threshold value of sensor (target value) + time and pause settings. Watering status, active valve and current results are displayed. Monitoring functions: warning sent when minimum threshold level reached (over watering) and maximum (dry), plus a pressure gauge is included for control of the pump flow and operating pressure; alarm outputs (complete system alarm or individual alarms for single sensors or pumps) for local warning display (individual signal generator) or as an option via SMS-alarm per GSM modem.
Article 1930 1932 1934 1938 1940
Model TC-10MAR TC-14MAR TC-20MAR TC-32MAR TC-40MAR
1945
TC-P35
1950 1952 1955 1957
TC-4AD TC-6AD TC-8EY TC-16EY
1960
TC-P57TK
1965
TC-Case
Description CPU with 4 outputs for valves (relays), DC/AC; non- expandable CPU with 6 outputs for valves (relays), DC/AC; non- expandable CPU with 8 outputs for valves (relays), DC/AC CPU with 12 outputs for valves (relays), DC/AC CPU with 16 outputs for valves (relays), DC/AC Touchscreen (LCD Touch Panel), 3.5”, serial connection, rail mounting for adding modules Input module for 4 analogue sensors, optionally with signals in mA or V Input module for 6 analogue sensors, optionally with signals in mA or V Expansion module with 8 outputs for valves (relays), DC/AC Expansion module with 16 outputs for valves (relays), DC/AC System control module with touchscreen (LCD Touch Panel), 5.7”, serial connection, mounted completely in the 25x18x9 cm housing, includes mains connection, with 10 m long cable for use separately. Assembly of central case for CPU + module + necessary additional parts; standard housing- 30x30x13 cm; separate calculation according to number and size of modules.
TensioLogger INL (Internetlogger) TensioLogger INL is a data recording device (data-logger), which enables the recording of soil moisture data in regular intervals, especially for digital sensors using SDI 12-protocol, for example, the moisture sensor TensioMark, but can also be used with analogue as well as electronic sensors (E-sensors), and for transmitting and monitoring data via internet. Operation/ Power supply: The Logger works in SDI 12 mode with a corresponding bus connection (3-wired cable), requires 8-14 V DC, powered over an integrated battery pack with about 10.5 V and 2.5 Ah (7x 1.5 V Lithium batteries). An external connection for batteries or mains connector is included as an alternative. The Logger offers 24, or optionally 48 channels, for connect-
ing SDI 12-sensors, either directly or over biased terminal nodes. When a sensor is used for measuring different factors, then 1 channel will be required for each factor, for example, a TensioMark unit in SDI 12mode used for measuring the soil moisture as well as the soil temperature (further sensors for climate or soil moisture available upon request). Analogue sensors with 0-2.5 V signals, power supply of 5 V, are connected over a special interface (with an analogue-digital-transformer), for example, for use with tensiometers of the E-sensor series CVR.
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
17
TensioLogger INL (Internetlogger)
www.tensio.de
TensioLogger INL - Internetlogger For other analogue sensors, it may be necessary to customize the signal of the external power source to fit the individual situation. In addition, there are a maximum of 4 counter inputs for counting events, such as the pulses from a precipitation gauge. Storage/ Transmission: 2 MB of permanent data memory is available, sufficient for up to about 250 000 values; data are saved in “csv” format. 1636 In the “standard” version Model INL 1630 02, data are read-out over a wireless USB-interface (Dangle), for example, 1621 USB-Dongle with a laptop or netbook (max. distance 30 m). More comfortable, however, is the option by Model INL 01 with an inchosen intervals when defined threshold tegrated GSM-modem. New data is sent via a GPRS-Service to levels have been exceeded or undercut. a Server at preset intervals and can then be viewed with the Design: TensioLogger INL has a two-part Internet-Browser (Software CSView) and further processed, for construction with a plastic housing, senexample, with Excel. Prerequisite: modem must have a SIMsors are connected over separate conneccard and a Server must be set-up (on one’s own computer or tion nodes- so that the Logger housing has on the Service-Domain). few direct cable inputs (making it better Settings: Parameters can be set either on site or over the Insealed)- and over plug connectors from ternet-Browser using the included GP-Shell software. Setting which the sensors can be easily detached. the parameters allows specific tasks to be assigned to specific Multiple connection nodes are joined in channels and sensors, for the alignment of the sensors, for setrows via plugs and SDI 12 bus connection ting the frequency of data retrieval, as well as for choosing (distance of max. 100 m). the transfer modality. A separate alarm can be activated for each channel to send a warning to up to 4 e-mail addresses in
Article
Model
1630
INL 01
1631
INL 02
1635 1636
18
INL-Kn 01 INL-Kn 02
Description TensioLogger with 48 channels and GSM modem for data transfer; includes: 1 digital connection box, USB-Dangle, external antenna, GP-Shell software for setting parameters + CSView for viewing data, integrated 10 V lithium battery pack, housing: ca. 190x120x90 mm with hinged lid TensioLogger with 48 channels without modem, for on-site data readouts; includes: 1 digital connection box, USB-Dangle, external antenna, GP-Shell software for setting parameters, integrated 10 V lithium battery pack, housing: ca. 190x120x90 mm with hinged lid Connection box with nodes for 6 digital sensors, box- 90x130x57 mm, with plug connection to Logger, includes biased electronic, removable sensor connections Connection box with nodes for 6 analogue sensors + 1 channel for counting, box: 90x130x57 mm with plug connection to Logger, includes interface-electronic
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
Additional Accessories
www.tensio.de
Additional Accessories Article
Model
KS
1306
AT LR 24 STN 12
1750 1801 1805
N 24
1806
SG
1302
Extension for capillary tubing, two-part with connecting tube, for small tensiometers* Removable T-piece connector, 90° or 45° 24 V DC load relays, 20 mA,, plug-ins in housing, for control of pumps* 12 V DC mains connector plug (13 V), 1 A, powered by TM, TSW, SM* 24 V DC mains connector, 1 A, (opt. 12 V) plug-ins in housing, IP 66 for use in wet rooms For Suction-Tensio set: collecting vessel + capillary tubing for suctioning of soil fluids
1806
1306
1801
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de
19
bambach GbR • Tensio-Technik • Peter-Spring-Str. 18 • 65366 Geisenheim • Germany
Partner (BGB company): Edith Bambach, Daniela Bambach • Phone: +49(0)6722-972168 • Fax: +49(0)6722-75157 • info@tensio.de VAT-Id: DE 815129733 • Tax-No.: 037 303 30035 • Bank: Nassauische Sparkasse Wiesbaden • BIC: NASS DE55 • IBAN: DE89510500150450038024 Offices: bambach GbR • Karlsbader Str. 28 • 74211 Leingarten • Phone: +49(0)7131-6421200 • Fax: +49(0)7131-740981 • shop@blumat.de