General catalogue COMMERCIAL AND TECHNICAL INFORMATION Domestic Range
Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the highest technological standards. For over 30 years BAXI SPA has provided a wide range of cutting-edge solutions, anticipating market evolutions and paying attention to customer needs.
How to read this catalogue In this catalogue we show the complete range of BAXI products. On each page, in addition to the product benefits, there is a detailed list of the appliance characteristics, a technical chart, and coloured icons. These icons refer to the specific pages of the technical section of the catalogue where, by segment, the technical drawings and all the specific accessories are represented.
In the technical section you will find:
Dimensional Flue pipe technical accessories drawings Graphs Flue systems
2
Hydraulic accessories
Thermoregulation accessories
Other accessories
More details and information on the website By accessing to the www.baxi.it, Reserved Area and then to the Tech Area, just after a quick registration it is possible to display and download the following documents:
• Certifications • Fault Finding List • General Catalogues • General informations catalogues of all Baxi products • Instructions Manuals • PCB Service Instructions • Spare Parts Catalogues • Technical Drawings • Technical INFO
Index Gas condensing boilers Hybrid sistems
4 12
Gas boilers Wall hung boilers
14
Floor standing boilers
26
Solar systems
28
Indirect cylinders
30
Water heaters
36
Technical section
38
3
Gas condensing boilers
Heating only and combi
With DHW ministorage
Combi with DHW storage
- Luna Platinum - Luna Duo-tec - Duo-tec Compact
- Duo-tec Max
- Nuvola Platinum - Nuvola Duo-tec
05 06 07 08 09 10
Combi with DHW storage and solar integration - Luna3 Comfort HT Solar 11
4
Gas condensing boilers
Luna Platinum
Technical pages 40-55 64-68 70-72 73-74 76-77
• • • • • • •
Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting; supplied with the boiler Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency Integrated control of a solar system* Complete soundproofing of the generator Full modulating circulating pump Frontal access for advanced diagnostics Modulation ratio
Control panel
the modulation system is able to adapt the heat output to the energy demanded by the building.
innovative removable control panel distinguished by a clear back-lighting and easiness of use, thanks to the navigation knob and two push-buttons dedicated to the set of the comfort and complete programming of the boiler.
Hydraulic system
3 way electric diverter valve (also heating only models) Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Full modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Cascade installation option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
*in case of contemporary control of a solar system and a zone by the wallmounted control panel, it is necessary to install a programmable clip in/external module THINK.
Combi 24 Product code Maximum DHW heat input
kW
Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60°C Maximum heating heat output 50/30°C Minimum heating heat output 80/60°C Minimum heating heat output 50/30°C
kW kW kW kW kW kW
Heating onlys 33
1.12
1.18
1.24
1.32
7102695 7102703 7102665 7108435 7106583 7108436 24,7 34 20,6 24 20 21,8 2,4 2,7
28,9 33 28 30,6 3,3 3,6
12,4 12 13,1 2 2,2
17,4 16,9 18,4 2,4 2,7
24,7 24 26,1 2,4 2,7
33 32 34,9 3,2 3,5
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
109,8 97,7 105,8 107,7 5 -5 10/0,8 25/80 35/60
109,8 97,8 105,8 107,8 5 -5 8/0,8 25/80 35/60
109,8 97,7 105,8 107,7 5 -5 8/0,8 25/80 35/60
109,8 97,6 105,7 107,6 5 -5 8/0,8 25/80 35/60
109,8 97,6 105,7 107,6 5 -5 10/0,8 25/80 35/60
Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Nominal efficiency 80/60°C Nominal efficiency 50/30°C Efficiency 30% NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range. DHW temperature range DHW production ΔT 25°C (1)
°C l/bar °C °C
109,8 97,7 105,8 107,6 5 -5 8/0,8 25/80 35/60
l/min
13,8
18,9
-
-
-
-
Minimum capacity DHW flow rate Minimum pressure DHW circuit Maximum pressure heating circuit Maximum pressure DHW circuit Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature
l/min bar bar bar m m kg/s kg/s °C
2 0,15 3 8 10 80 0,012 0,001 80
2 0,15 3 8 10 80 0,016 0,002 80
3 10 80 0,006 0,001 75
3 10 80 0,008 0,001 75
3 10 80 0,012 0,001 80
3 10 80 0,016 0,002 80
Dimensions (h x w x d) Net weight Gas type Power consumption
mm kg
36
38
34,5
37,5
Grade of protection
% % % %
W
120
145
IPX5D
IPX5D
760 x 450 x 345 34,5 34,5 Natural Gas 108 122 IPX5D
IPX5D
120
130
IPX5D
IPX5D
(1) without flow restrictor. s
Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. See page 31 for sanitary performance.
5
Luna Duo-tec
Technical pages 40-55 64-68 70-72
• • • • • • •
Modulation ratio the modulation system is able to adapt the heat output to the energy demanded by the building.
on the control panel there is easy access for the diagnostics. With a USB connection it is possible to check single boilers or multiple boilers functions.
Combi
Hydraulic system
Thermoregulation system
Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option
Control system
Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
24
28
33
Heating onlys 40
1.12
1.24
1.28
7101931 7101932 7101933 7102871 7102852 7102853 7105684
Product code Maximum DHW heat input
kW
24,7
28,9
34
41,2
-
-
-
Maximum heating heat input
kW
20,6
24,7
28,9
33
12,4
24,7
28,9
Maximum DHW heat output
kW
24
28
33
40
-
-
-
Maximum heating heat output 80/60°C
kW
20
24
28
32
12
24
28
Maximum heating heat output 50/30°C
kW
21,8
26,1
30,6
34,9
13,1
26,1
30,5
Minimum heating heat output 80/60°C
kW
3,4
3,8
4,7
5,7
2
3,4
4
Minimum heating heat output 50/30°C
kW
3,7
4,1
5,1
6,3
2,2
3,7
4,3
Energetic efficiency (92/42/CEE)
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
Average efficiency (DIN 4702-T8)
%
109,8
109,8
109,8
109,8
109,8
109,8
109,8
Nominal efficiency 80/60°C
%
97,7
97,7
97,7
97,7
97,8
97,6
97,6
Nominal efficiency 50/30°C
%
105,8
105,8
105,8
105,8
105,8
105,7
105,7
Efficiency 30%
%
107,6
107,6
107,7
107,7
107,8
107,6
107,6
5
5
5
5
5
5
5
-5
-5
-5
-5
-5
-5
-5
NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range. DHW temperature range
°C l/bar
8/0,8
8/0,8
10/0,8 10/0,8
8/0,8
8/0,8
8/0,8
°C
25/80
25/80
25/80
25/80
25/80
25/80
25/80
°C
35/60
35/60
35/60
35/60
35/60
35/60
35/60
DHW production ΔT 25°C (1)
l/min
13,8
16,1
18,9
22,9
-
-
-
Minimum capacity DHW flow rate
l/min
2
2
2
2
-
-
-
Minimum pressure DHW circuit
bar
0,15
0,15
0,15
0,15
-
-
-
Maximum pressure heating circuit
bar
3
3
3
3
3
3
3
Maximum pressure DHW circuit
bar
8
8
8
8
-
-
-
m
10
10
10
10
10
10
10
Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length
m
80
80
80
80
80
80
80
Maximum flue mass flow rate
kg/s
0,012
0,014
0,016
0,019
0,006
0,012
0,014
Minimum flue mass flow rate
kg/s
0,002
0,002
0,002
0,003
0,001
0,002
0,002
Maximum flue temperature
°C
80
80
80
80
75
80
80
Dimensions (h x w x d)
mm
Net weight
kg
38,5
38,5
39,5
34,5
36
760 x 450 x 345
Gas type Power consumption Grade of protection
6
76-77
Digital control panel with back-lighted LCD display Wide modulation ratio up to 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency Modulating circulating pump Complete soundproofing of the generator Frontal access for advanced diagnostics Integration with solar system option Diagnostics
3 way electric diverter valve (also heating only models) Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar
74
41
34,5
Natural Gas/LPG W
102
114
133
142
108
102
114
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
(1) without flow restrictor. s
Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. See page 31 for sanitary performance.
Gas condensing boilers
Duo-tec Compact
Technical pages 41-55 64-68 70-72
74
76-77
• Digital control panel with back-lighted wide LCD display • Wide modulation ratio up to 1÷7: better efficiency thanks to
reduced switch-on/switch-off of the boiler • Ultra compact dimensions (700x400x299 mm) • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Modulating circulating pump • Complete soundproofing of the generator Compact dimensions
Modulation ratio the modulation system is able to adapt the heat output to the energy demanded by the building.
Duo-tec Compact is ideal to be installed in narrow space thanks to its compact dimensions
Combi
Hydraulic system
3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar
Thermoregulation system
Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option
Control system
Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
Product code
Heating onlys
24
1.24
7106765
7108974
Maximum DHW heat input
kW
24,7
-
Maximum heating heat input
kW
20,6
24,7
Maximum DHW heat output
kW
24
-
Maximum heating heat output 80/60°C
kW
20
24
Maximum heating heat output 50/30°C
kW
21,8
26,1
Minimum heating heat output 80/60°C
kW
3,4
3,4
Minimum heating heat output 50/30°C
kW
3,7
3,7
Energetic efficiency (92/42/CEE)
HHHH
HHHH
Average efficiency (DIN 4702-T8)
%
109,8
109,8
Nominal efficiency 80/60°C
%
97,7
97,6
Nominal efficiency 50/30°C
%
105,8
105,7
Efficiency 30%
%
107,6
107,6
NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range. DHW temperature range
°C
5
5
-5
-5
l/bar
7/0,8
8/0,8
°C
25/80
25/80
°C
35/60
35/60
DHW production ΔT 25°C (1)
l/min
13,8
-
Minimum capacity DHW flow rate
-
l/min
2
Minimum pressure DHW circuit
bar
0,15
-
Maximum pressure heating circuit
bar
3
3
Maximum pressure DHW circuit
bar
8
-
m
10
10
Coaxial flue system Ø 60/100 max length
m
80
80
Maximum flue mass flow rate
Dual flue system Ø 80 max length
kg/s
0,011
0,012
Minimum flue mass flow rate
kg/s
0,002
0,002
Maximum flue temperature
°C
80
80
Dimensions (h x w x d)
mm
700x400x299
700 x 400 x 299
Net weight
kg
34
30
Gas type Power consumption Grade of protection
Natural Gas/LPG W
104
102
IPX5D
IPX5D
(1) without flow restrictor. s
Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. page 31 for sanitary performance.
7
Duo-tec Max
Technical pages 41-55 64-68 70-72
74
76-77
• Digital control panel with back-lighted LCD display • Mini storage tank integrated in the expansion vessel (patented by Baxi) • *** DHW comfort (EN 13203) • Wide modulation ratio 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Circulating pump with modulation • Complete soundproofing of the generator • Frontal access for advanced diagnostics Sanitary comfort
Modulation ratio
Thanks to the mini storage tank and to the enhanced plate heat exchanger, DHW is quickly available, at a constant temperature also with different flow rates
the modulation system is able to adapt the heat output to the energy demanded by the building.
Combi with DHW integrated mini storage tank
Hydraulic system
3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar
Thermoregulation system
Product code kW
24,7
34
Maximum heating heat input
kW
20,6
28,9
Maximum DHW heat output
kW
24
33
Maximum heating heat output 80/60°C
kW
20
28
Maximum heating heat output 50/30°C
kW
21,8
30,6
Minimum heating heat output 80/60°C
kW
3,4
4,7
Minimum heating heat output 50/30°C
kW
3,7
5,1
Energetic effi ciency (92/42/CEE)
HHHH
HHHH
Average efficiency (DIN 4702-T8)
%
109,8
109,8
Nominal efficiency 80/60°C
%
97,7
97,7
Nominal efficiency 50/30°C
%
105,8
105,8
Effi ciency 30%
%
107,6
107,7
NOx class (EN 483)
Control system
Mini storage tank capacity
Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range. DHW temperature range
5
5
°C
-5
-5
l/bar
8/0,8
8/0,8
l
4
4
°C
25/80
25/80
°C
35/60
35/60
DHW production ΔT 25°C (1)
l/min
13,8
18,9
Minimum capacity DHW flow rate
l/min
2
2
Minimum pressure DHW circuit
bar
0,15
0,15
Maximum pressure heating circuit
bar
3
3
Maximum pressure DHW circuit
bar
8
8
m
10
10
Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length
m
80
80
Maximum flue mass flow rate
kg/s
0,012
0,016
Minimum flue mass flow rate
kg/s
0,002
0,002
Maximum flue temperature
°C
80
80
Dimensions (h x w x d)
mm
760 x 450 x 345
760 x 450 x 345
Net weight
kg
38,5
39,5
Natural Gas/LPG
Natural Gas/LPG
Gas type Power consumption Grade of protection
8
33 7102880
Maximum DHW heat input
Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Safety NTC sensor against flues overheat Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
24 7102879
(1) without flow restrictor.
W
102
133
IPX5D
IPX5D
Gas condensing boilers
Nuvola Platinum
Technical pages 42-55 64-68 70-72 73-74 76-77
• Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting; supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Full modulating circulating pump • High DHW performances: up to 500 lt in 30 minutes (33 kW model) • Integrated sanitary expansion vessel • Frontal access for advanced diagnostics Modulation ratio
Control panel
the modulation system is able to adapt the heat output to the energy demanded by the building.
innovative removable control panel distinguished by a clear back-lighting and easiness of use, thanks to the navigation knob and two push-buttons dedicated to the set of the comfort and complete programming of the boiler.
Hydraulic system
3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger Stainless steel AISI 316L tank Modulating fan with electronic speed adjusting system Automatic by-pass Full modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Tank relief valve set at 8 bar Integrated sanitary 2 litres expansion vessel Sanitary recirculation option
Thermoregulation system
Integrated climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Anti legionella function Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
Combi with DHW storage 24
33 7107052 34
Product code Maximum DHW heat input
kW
7107051 24,7
Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60°C Maximum heating heat output 50/30°C Minimum heating heat output 80/60°C Minimum heating heat output 50/30°C
kW kW kW kW kW kW
20,6 24 20 21,8 2,4 2,7
28,9 33 28 30,6 3,3 3,6
HHHH
HHHH
°C l/bar °C °C l l/bar l/min
109,8 97,7 105,8 107,6 5 -5 7,5/0,8 25/80 35/60 45 2/3,5 16,6
109,8 97,7 105,8 107,7 5 -5 7,5/0,8 25/80 35/60 45 2/3,5 19,5
DHW production at discharge ΔT 30°C (1)
l/min l/30’
13,8 385
18,9 500
Maximum pressure heating circuit Maximum pressure DHW circuit Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature
bar bar m m kg/s kg/s °C
3 8 10 80 0,012 0,001 80
3 8 10 80 0,016 0,002 80
Dimensions (h x w x d) Net weight Gas type Power consumption
mm Kg
950x600x466 62 Natural Gas 120
950x600x466 64 Natural Gas 145
IPX5D
IPX5D
Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Nominal efficiency 80/60°C Nominal efficiency 50/30°C Efficiency 30% NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range DHW temperature range Tank capacity Tank expansion vessel capacity/pre-charge Specific flow rate (EN 625) DHW production ΔT 25°C (1)
Grade of protection
% % % %
W
(1) without flow restrictor.
9
Nuvola Duo-tec
Technical pages 42-55 64-68 70-72
74
76-77
• Digital control panel with back-lighted LCD display • Wide modulation ratio up to 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Modulating circulating pump • High DHW performances: up to 385 lt in 30 minutes (∆T 30°C) • Stainless steel AISI 316L 45 lt cylinder • Frontal access for advanced diagnostics Modulation ratio
Diagnostics
the modulation system is able to adapt the heat output to the energy demanded by the building.
on the control panel there is easy access for the diagnostics. With a USB connection it is possible to check single boilers or multiple boilers functions.
Combi with DHW storage
Hydraulic system
3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger Stainless steel AISI 316L tank Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar Tank relief valve set at 8 bar Sanitary 2 litres expansion vessel available as optional Sanitary recirculation option
Thermoregulation system
Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option
Control system
Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Anti legionella function Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge
Product code
24
7105982
7105983
Maximum DHW heat input
kW
16,5
24,7
Maximum heating heat input
kW
12,4
20,6
Maximum DHW heat output
kW
16
24
Maximum heating heat output 80/60°C
kW
12
20
Maximum heating heat output 50/30°C
kW
13,1
21,8
Minimum heating heat output 80/60°C
kW
2,2
3,4
Minimum heating heat output 50/30°C
kW
2,4
3,7
Energetic efficiency (92/42/CEE)
HHHH
HHHH
Average efficiency (DIN 4702-T8)
%
109,8
109,8
Nominal efficiency 80/60°C
%
97,8
97,7
Nominal effi ciency 50/30°C
%
105,8
105,8
Effi ciency 30%
%
107,8
107,6
NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge
5
5
°C
-5
-5
l/bar
7,5/0,8
7,5/0,8
Heating temperature range.
°C
25/80
25/80
DHW temperature range
°C
35/60
35/60
l
45
45
Tank expansion vessel capacity/pre-charge
l/bar
2/2,5
2/2,5
Specific flow rate (EN 625)
l/min
13,3
16,6
DHW production ΔT 25°C (1)
l/min
9,2
13,8
l/30’
275
385
Maximum pressure heating circuit
bar
3
3
Maximum pressure DHW circuit
bar
8
8
m
10
10
Tank capacity
DHW production at discharge ΔT 30°C
(1)
Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length
m
80
80
Maximum flue mass flow rate
kg/s
0,008
0,012
Minimum flue mass flow rate
kg/s
0,001
0,002
Maximum flue temperature
°C
75
80
Dimensions (h x w x d)
mm
950x600x466
950x600x466
Net weight
Kg
62
62
Natural gas/LPG
Natural gas/LPG
Gas type Power consumption Grade of protection (1) without flow restrictor.
10
16
W
112
102
IPx5D
IPx5D
Gas condensing boilers
Luna3 Comfort HT Solar
Technical pages 43-55 64-68 70-72
75
76-77
• Wide modulation ratio 1÷6: better and noiseless boiler working • 200 lt thermal stratification cylinder made of vitrified steel with solar integration • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Mixed system (low and high temperature) installation option • Built-in climatic regulation (outdoor sensor available as optional) • Controller, expansion vessel and hydraulic group for the solar system, integrated in the boiler casing Stratification cylinder
Modular installation
Hydraulic system
3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger with sound proofing composite casing Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode 200 lt thermal stratification cylinder made of vitrified steel with solar integration through coil exchanger Modulating fan with electronic speed adjusting system Automatic by-pass Multi-speeds low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Circulating pump for the cylinder Cylinder expansion vessel Solar expansion vessel Solar hydraulic group (pump, safety valve, flow rate regulator, air vent) Thermostatic mixing valve on the DHW outlet of the cylinder Sanitary recirculation option
Thermoregulation system
Solar controller (pump and two temperature sensors) Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, central heating and sanitary timers included in the control panel
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in the event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Anti-legionella function Full anti-frost device Thermometer of the cylinder Heating circuit electronic thermometer Heating circuit pressure gauge
The 200 litres cylinder with thermal stratification grants a fast heating of the sanitary water through an enhanced plates exchanger, ensuring high performance and constant availability of domestic hot water.
Luna3 Comfort HT Solar has been designed to grant the maximum installation flexibility also in narrow spaces. It is possible to install the boiler separately from the cylinder.
Combi with DHW storage and solar integration 120-120 MS*
240-240 MS*
Product code Maximum DHW heat input
HLZ kW
71413001-71413011 12,4
71411691-71412971 24,7
Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60 °C Maximum heating heat output 50/30 °C Minimum heat output 80/60 °C Minimum heat output 50/30 °C
kW kW kW kW kW kW
12,4 12 12 13 2** 2,2**
20,5 24 20 21,6 4 4,3
°C l/bar
HHHH 109,8 97,6 105,1 108 5 -5 8/0,5
HHHH 109,8 97,6 105,1 107,5 5 -5 8/0,5
Solar expansion vessel capacity / pre-charge l Heating temperature range °C DHW temperature range °C Cylinder capacity l Cylinder expansion vessel capacity / pre-charge l Specific flow rate (EN 625) l/min DHW production ∆T 25°C (1) l/min
18/2,5 20/80 35/60 200 8/3,5 18,5 6,9
18/2,5 20/80 35/60 200 8/3,5 27 13,8
Maximum pressure heating circuit Maximum pressure DHW circuit Maximum pressure DHW solar circuit Coaxial flue system Ø 60/100 max length Duel flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature
bar bar bar m m kg/s kg/s °C
3 8 6 10 80 0,006 0,002 73
3 8 6 10 80 0,012 0,002 73
Dimensions (h x w x d) Net weight Gas type
mm kg
Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Minimum heat output 80/60 °C Minimum heat output 50/30 °C Energetic efficiency 30% Nox class (EN 483) Minimum working temperature Expansion vessel capacity / pre-charge
Power consumption Grade of protection
% % % %
2056x600x640 170-194 (MS) 170-194 (MS) Nat. gas / LPG
W
297-497 (MS)
297-497 (MS)
IPX5D
IPX5D
(1) without flow restrictor. * Model with mixed system supplied with the boiler. **Boiler working with Natural gas. In case of LPG convertion the minimum output is 3,9 kW (80/60°C) and 4,2 kW (50/30°C)
11
Hybrid Systems
12
- Luna Platinum CSI
13
Hybrid Systems
Luna Platinum CSI
Technical pages
43
The integrated hybrid system consists of: • A condensing gas boiler (3,3 – 33 kW) • A 6 or 8 or 11 kW electric heat pump (depending on the building loads) • A solar thermal system (two 2,5 sqm collectors) • A 300 lt stainless steel integrated cylinder with solar coil • Built-in control of mixed systems: 1 high temperature zone + 2 low temperature zones (independent temperatures) Luna Platinum CSI
Luna Platinum CSI (Complete System Integration)
is an integrated multi-energy and multitechnology system for home comfort. It combines various technologies: solar system, water/air heat pump, gas condensing boiler
is an integrated COMPACT system which combines heating technologies and energy sources to provide energy efficient complete integrated systems and grant maximum comfort (with water production for heating, DHW and cooling), indipendently from outside weather conditions.
Combi with storage and solar integration (buffer tank)
Features
• Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting • Control of solar system integration • Control of low temperature system • Outside temperature check related to heat pump control • Outdoor sensor • Modulation ratio up to 1:10: highest efficiency in low heat demand installations • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Built-in solar system integration • Complete soundproofing of the generator • Circulating pump with full modulation • Frontal access for advanced diagnostics • Heating expansion vessel: 24 lt + 6 lt for cooling • Solar expansion vessel: 18 lt • Anti-legionella system not necessary as the cylinder contains primary water • Specific flow rate ∆t 30°C; 27 l/min*
Product code
633
833
1133
710799401 (with 6 kw h.p.)
710799501 (with 8 kw h.p.)
710874701 (with 11 kw h.p.)
Maximum DHW heat input
kW
34
Maximum heating heat input Range of DHW heat output Range of heating heat output Energetic efficiency (92/42/CEE) DHW production ∆T 30°C
kW kW kW
28,9 3,3-33 3,3-28
Dimensions h x w x d
HHHH
lt/min
27
mm
2060x868x672
Integrable heating pumps
RO.6/1.BT
RO.8/1.BT
RO.11/3.BT
kW
6,80
8,45
11,2
COP ¹ Nominal cooling output ² EER ²
kW
3,90 6,7 3,2
4,00 8,7 3,0
4,4 9,5 3,0
Dimensions hxwxd
mm
735x1190x340
735x1190x340
1235x1190x340
Nominal heating capacity ¹
(1) Outdoor air temperature 7°C (d.b.)/6°C (w.b) and flow temperature 35°C (2) Outdoor air temperature 35°C (d.b.) and flow temperature 18°C
* l/min water at the tap
13
Gas boilers Wall hung boilers
Heating only and combi
- Luna3 Comfort 15 - Luna3 16 Outdoor installation - Luna3 Comfort Air 17
Low NOx
- Luna3 Blue
18
With micro storage
- Luna3 Comfort Max
19
With storage
Outdoor installation
- Nuvola3 Comfort - Nuvola3 BS
- Luna3 Silver Space
20 21 22
Ultra compact dimensions - Ecofour 23 - Fourtech 24 - Mainfour 25
Floor standing boilers
Heating only and combi with storage
Heating only
14
- Slim
- Slim HP
26 27
Gas boilers
Luna3 Comfort
Technical pages 44-57 65-68 70-72
75
76-77
• Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Enhanced heat exchanger • Hydraulic group made of brass and flowmeter with turbine (combi models) • Sanitary pre-heating function • Connection to Baxi integrated solar systems option
Enhanced heat exchanger
Connection to solar systems
Made of copper pipes protected with anticorrosion coating. It has a wide surface of exchange.
Electronics has been designed to allow the boiler to turn on only when the cylinder temperature is lower than the one requested.
Combi Fanned flue
Hydraulic system
240 Fi
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger (combi models) Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar (1)
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel Sanitary timer (indirect cylinder)
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge (1)
In the heating only models, the electric motor is available as optional.
Product code
Natural Gas LPG
Heating only* Open flue
310 Fi
240 i
Open flue
Fanned flue 1.240 Fi
45631358 45224358 45524358 45631158 CSZ 45224158
1.310 Fi
1.240 i
45531358 45531158
45124358
CSE
45624358 45624158
Maximum heat input
kW
26,9
33,3
26,3
26,9
33,3
26,3
Minimum heat input
kW
10,6
11,9
10,6
10,6
11,9
10,6
Maximum heat output
kW
25
31
24
25
31
24
Minimum heat output
kW
9,3
10,4
9,3
9,3
10,4
9,3
Maximum efficiency
%
91,2
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature
%
92,9
93,1
91,2
92,9
93,1
HHH
HHH
HH
HHH
HHH
HH
90,2
90,8
90,29
90,2
90,8
90,29
°C
-5
-5
-5
-5
-5
-5
Expansion vessel/pre-charge
l/bar
8/0,5
10/0,5
8/0,5
8/0,5
10/0,5
8/0,5
Heating system max pressure
bar
3
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/60
35/60
35/60
35/60
35/60
35/60
DHW production ∆T 25°C
l/min
14,3
18
13,7
-
-
-
Minimum capacity DHW flow rate
l/min
2
2
2
-
-
-
Minimum pressure on DHW circuit
bar
0,15
0,15
0,15
-
-
-
Maximum pressure on DHW circuit
bar
8
8
8
-
-
-
Ø mm
-
-
120
-
-
120 -
Flue tube Coaxial flue system Ø 60/100
m
5
4
-
5
4
Dual flue system Ø 80 max length
m
40
25
-
40
25
-
Maximum flue mass flow rate
kg/s
0,017
0,018
0,019
0,017
0,018
0,019
Minimum flue mass flow rate
kg/s
0,017
0,019
0,017
0,017
0,019
0,017
Maximum flue temperature
°C
135
145
110
135
145
110
Dimensions (h x w x d)
mm
Net weight
kg
38
40
38
31
730x400x299
Gas type Power consumption Grade of protection
33
36
Natural Gas/LPG W
135
165
80
135
165
80
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
* Heating only models are connectable to combi 80 lt/UB-UB INOX 80/120 lt. page 31 for sanitary performance.
15
Luna3
Technical pages 44-57 65-68 70-72
• • • • • •
75
Digital control panel with wide LCD display Enhanced heat exchanger Hydraulic group made of brass and flowmeter with turbine (combi models) Sanitary pre-heating function Connection to Baxi integrated solar systems option Built-in climatic regulation (outdoor sensor available as optional)
Wide LCD display
Hydraulic group made of brass
The interaction with the boiler is easier thanks to information clearly displayed in the wide LCD display and dedicated push-buttons for setting and regulation.
Luna3 is provided with 3 way electric valve. Thanks to the flowmeter with turbine, the sanitary water is detected and gauged.
Heating only*
Combi
Hydraulic system
Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger (combi models) Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Remote controller and climatic regulator option Built-in climatic regulation (outdoor sensor available as optional)
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge
Open flue
Fanned flue 240 Fi Product code
Natural Gas LPG
CSB
280 Fi
310 Fi
45624366 CSE 45628366 45631366 45631166 45624166
Fanned flue
240 i
1.310 Fi
45224366 45224166
45531366 45531166
Maximum heat input
kW
26,9
30,1
33,3
26,3
33,3
Minimum heat input
kW
10,6
11,9
11,9
10,6
11,9
Maximum heat output
kW
25
28
31
24
31
Minimum heat output
kW
9,3
10,4
10,4
9,3
10,4
Maximum efficiency
%
Energetic efficiency (92/42/CEE)
92,9
93,1
93,1
91,2
93,1
HHH
HHH
HHH
HH
HHH 90,8
Efficiency at 30%
%
90,2
90,8
90,8
90,29
Minimum working temperature
°C
-5
-5
-5
-5
-5
Expansion vessel/pre-charge
l/bar
8/0,5
10/0,5
10/0,5
8/0,5
10/0,5
Heating system max pressure
bar
3
3
3
3
3
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in heating circuit Regulation of water temperature in DHW circuit
°C
35/60
35/60
35/60
35/60
35/60
DHW production ∆T 25°C
l/min
14,3
16
18
13,7
-
Minimum capacity DHW flow rate
l/min
2
2
2
2
-
Minimum pressure on DHW circuit
bar
0,15
0,15
0,15
0,15
-
Maximum pressure on DHW circuit
bar
8
8
8
8
-
Ø mm
-
-
-
120
-
m
5
4
4
-
4
Flue tube Coaxial flue system Ø 60/100
m
40
25
25
-
25
Maximum flue mass flow rate
Dual flue system Ø 80 max length
kg/s
0,017
0,017
0,018
0,019
0,018
Minimum flue mass flow rate
kg/s
0,017
0,017
0,019
0,017
0,019
Maximum flue temperature
°C
135
140
145
110
145
Dimensions (h x w x d)
mm
Net weight
kg
38
40
33
38
760x450x345
Gas type Power consumption Grade of protection
40 Natural Gas/LPG
W
135
165
165
80
165
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
* Heating only models are connectable to UB-UB INOX 80/120 lt. See page 31 for sanitary performance.
16
76-77
Gas boilers
Luna3 Comfort Air
Technical pages 45-57 65-68 70-72
75
76-77
• Remote control (WIRELESS data transmission) with LCD display, room thermostat heating and sanitary timer function included • Outdoor installation in partially protected places thanks to the grade of protection IPX5D and to the possibility of functioning up to -15°C • Enhanced heat exchanger • Sanitary pre-heating function • Connection to Baxi integrated solar systems option
WIRELESS remote control
OUTDOOR installation
It allows a complete managing of the domestic comfort from inside. The WIRELESS transmission that occurs between the boiler and the remote control makes installation process easier since electric connections between the boiler and the remote control are not necessary.
In partially protected places thanks to the grade of protection IPX5D and to the possibility of functioning up to -15°C
Hydraulic system
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge
Combi Fanned flue 250 Fi
310 Fi
CSB
45625369 45625169
45631369 45631169
Maximum heat input
kW
26,9
33,3
Minimum heat input
kW
10,6
11,9
Maximum heat output
kW
25
31
Minimum heat output
kW
9,3
10,4
Maximum efficiency
%
Product code
Natural Gas LPG
Energetic efficiency (92/42/CEE)
92,9
93,1
HHH
HHH 90,8
Efficiency at 30%
%
90,2
Minimum working temperature
°C
-15
-15
Expansion vessel/pre-charge
l/bar
8/0,5
10/0,5
Heating system max pressure
bar
3
3
°C
30/85 30/45
30/85 30/45
Regulation of water temperature in heating circuit
°C
35/60
35/60
DHW production ∆T 25°C
Regulation of water temperature in DHW circuit
l/min
14,3
18
Minimum capacity DHW flow rate
l/min
2
2
Minimum pressure on DHW circuit
bar
0,15
0,15
Maximum pressure on DHW circuit
8
bar
8
Coaxial flue system Ø 60/100
m
5
4
Dual flue system Ø 80 max length
m
40
25
Maximum flue mass flow rate
kg/s
0,017
0,018
Minimum flue mass flow rate
kg/s
0,017
0,019
Maximum flue temperature
°C
135
145
Dimensions (h x w x d)
mm
Net weight
kg
763x450x345 38
Gas type Power consumption Grade of protection
40 Natural Gas/LPG
W
135
165
IPX5D
IPX5D
17
Luna3 Blue
Technical pages 46-57 65-68 70-72
75
76-77
• Low NOx burner-Class NOx 5 • Constant efficiency at over 93% for all heat inputs (fanned flue models) • Hydraulic group made of brass and flowmeter with turbine (combi models) • Sanitary pre-heating function • Connection to Baxi integrated solar systems option
Low NOx burner
Constant efficiency
The burner has been designed to grant NOx emissions lower than 10mg/kWh
Constant efficiency at over 93% for all heat inputs (fanned flue models)
Hydraulic system
3 way electric diverter valve Water refrigerated Low NOx burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW exchanger (combi models) Modulating fan with electronic speed adjusting system (fanned flue models) Automatic by-pass Multi-speeds low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Remote controller and climatic regulator (supplied as optional)
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Chimney sweeper function Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge
Combi
Heating only*
Fanned flue
Open flue
Open flue
240Fi
280Fi
180i
240i
1.240Fi
1.180i
ESB
45624366
45628366
45218366
45224366
45524366
45118366
Maximum efficiency
%
93,2
93,1
90,3
90,3
93,2
90,3
Minimum heat input
kW
11,9
11,9
10,6
11,9
11,9
10,6
Maximum heat output
kW
24
28
17,5
24
24
17,5
Minimum heat output
kW
10,7
10,7
9,3
10,4
10,7
9,3
Maximum efficiency
%
92,9
91,2
Product code
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature
%
92,9
93,1
91,2
HHH
HHH
HH
HH
HHH
HH
91,2
92,5
89,6
89,6
91,2
89,6
°C
-5
-5
-5
-5
-5
-5
Expansion vessel/pre-charge
l/bar
8/0,5
10/0,5
8/0,5
8/0,5
8/0,5
8/0,5
Heating system max pressure
bar
3
3
3
3
3
3
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in heating circuit Regulation of water temperature in DHW circuit
°C
35/60
35/60
35/60
35/60
35/60
35/60
DHW production ∆T 25°C
l/min
13,7
16
10
13,7
-
-
Minimum capacity DHW flow rate
l/min
2
2
2
2
-
-
Minimum pressure on DHW circuit
bar
0,15
0,15
0,15
0,15
-
-
Maximum pressure on DHW circuit
bar
8
8
8
8
-
-
Ø mm
-
-
110
130
-
110 -
Flue tube Coaxial flue system Ø 60/100
m
4
4
-
-
4
Dual flue system Ø 80 max length
m
20
20
-
-
20
-
Maximum flue mass flow rate
kg/s
0,018
0,017
0,015
0,009
0,018
0,015
Minimum flue mass flow rate
kg/s
0,015
0,014
0,012
0,035
0,015
0,012
Maximum flue temperature
°C
135
140
120
120
135
100
Dimensions (h x w x d)
mm
Net weight
kg
41,5
42
31
39,5
29
760x450x345
Gas type Power consumption Grade of protection
33
Natural Gas/LPG W
135
165
110
110
135
110
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
*Heating only models are connectable to UB-UB INOX 80/120 lt. page 31 for sanitary performance.
18
Fanned flue
Gas boilers
Luna3 Comfort Max
Technical pages 46-57 65-68 70-72
75
76-77
• Micro storage tank integrated in the expansion vessel (patented Baxi) and ***DHW comfort (EN 13203) • Enhanced heat exchanger • Hydraulic group made of brass and flowmeter with turbine (combi models) • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions
Integrated micro storage tank
Sanitary comfort Thanks to the micro storage tank and to the enhanced plate heat exchanger, DHW is quickly available, at a constant temperature also with different flow rates
The special expansion vessel with integrated micro storage, grants DHW always at your disposal, to satisfy, without waiting times any sanitary demand.
Hydraulic system
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Automatic by-pass Multi-speeds low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as option) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge
Combi with DHW micro-storage Fanned flue
Open flue
250Fi
310Fi
240 i
Product code
CSB
45825358
45831358
45324358
Maximum heat input
kW
26,9
33,3
26,3
Minimum heat input
kW
10,6
11,9
10,6
Maximum heat output
kW
25
31
24
Minimum heat output
kW
9,3
10,4
9,3
Maximum efficiency
%
92,9
93,1
91,2
HHH
HHH
HH
90,2
90,8
90,29
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature
% °C
-5
-5
-5
Expansion vessel/pre-charge
l/bar
8/0,5
8/0,5
8/0,5
Micro storage tank capacity
l
3,5
3,5
3,5
°C
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in heating circuit
°C
35/60
35/60
35/60
DHW production ∆T 25°C
Regulation of water temperature in DHW circuit
l/min
14,3
18
13,7
Minimum capacity DHW flow rate
l/min
2
2
2
Minimum pressure on DHW circuit
bar
0,15
0,15
0,15
bar
8
8
8
Ø mm
-
-
120 -
Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100
m
5
4
Dual flue system Ø 80 max length
m
40
25
-
Maximum flue mass flow rate
kg/s
0,017
0,018
0,019
Minimum flue mass flow rate
kg/s
0,017
0,019
0,017
Maximum flue temperature
°C
135
145
110
Dimensions (h x w x d)
mm
Net weight
kg
760x450x345 33
Gas type Power consumption Grade of protection
38
40
Natural Gas/LPG W
135
165
80
IPX5D
IPX5D
IPX5D
19
Nuvola3 Comfort
Technical pages 47-57 65-68 70-72
75
76-77
• Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • High sanitary performances: up to 490 lt in 30 min (∆T 30°C) • 60 lt stainless steel cylinder • Built-in sanitary expansion vessel
High performance
Built-in expansion vessel
Nuvola3 Comfort is the range with integrated storage which grants high sanitary performance and it represents the ideal solution in case of simultaneous big hot water demands.
Nuvola3 Comfort is provided with a built-in sanitary expansion vessel which represents the ideal solution in case of high pressures on the mains sanitary water.
Hydraulic system
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating 60 lt stainless steel AISI 316L cylinder Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Built-in sanitary 2 litres expansion vessel Sanitary recirculation option
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Anti-legionella function Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge
Combi with DHW storage Fanned flue 240 Fi
280 Fi
320 Fi
240 i
280 i
CSB
45714358
45724358 45724158
45728358 45728158
45732358 45732158
45424358
45428358
Maximum heat input
kW
15,3
26,3
30,1
34,5
27,1
31,1
Minimum heat input
kW
6,9
11,9
11,9
11,9
11,9
11,9
Maximum heat output
kW
14
24,4
28
32
24,4
28
Minimum heat output
kW
6
10,4
10,4
10,4
10,4
10,4
Maximum efficiency
%
90,9
92,9
93,1
93,2
90,2
90,6
%
HH 88,3
HHH 90,4
HHH 90,5
HHH 90,5
HH 89,4
HH 89,5
Product code
Natural Gas LPG
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature
°C
-5
-5
-5
-5
-5
-5
Expansion vessel/pre-charge
l/bar
7,5/0,5
7,5/0,5
7,5/0,5
7,5/0,5
7,5/0,5
7,5/0,5
Heating system max pressure
bar
3
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/65
35/65
35/65
35/65
35/65
35/65
l
60
60
60
60
60
60
l/bar
2/3,5
2/3,5
2/3,5
2/3,5
2/3,5
2/3,5
Specific flow according to EN 625
l/min
14,1
18,2
19
21,5
18,2
19
DHW production ∆T 25°C
l/min
8,1
14
16,1
18,3
14
16,1
l/30’
260
390
450
490
390
450
bar
8
8
8
8
8
8
Ø mm
-
-
-
-
140
140 -
Cylinder capacity Cylinder expansion vessel capacity/pre-charge (1)
DHW production at discharge ∆T 30°C Maximum pressure on DHW circuit Flue tube
(1)
Coaxial flue system Ø 60/100
m
5
4
4
4
-
Dual flue system Ø 80 max length
m
30
30
30
30
-
-
Maximum flue mass flow rate
kg/s
0,015
0,018
0,018
0,022
0,022
0,024
Minimum flue mass flow rate
kg/s
0,015
0,017
0,018
0,021
0,021
0,021
Maximum flue temperature
°C
120
134
142
142
110
115
Dimensions (h x w x d)
mm
Net weight
kg
70
70
60
60
950x600x466
Gas type Power consumption Grade of protection (1)
20
Open flue
140 Fi
Without flow restrictor.
70
70
Natural Gas/LPG W
190
190
190
190
110
110
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
Gas boilers
Nuvola3 BS
Technical pages 47-57 65-68 70-72
75
76-77
• 30 lt thermal dynamic stratification cylinder: - immediate DHW delivery thanks to 30 lt storage ready to be used at the needed temperature - less scale formation thanks to the DHW plates exchanger - high sanitary performances thanks to high efficiency of heat exchanger • Vertical hydraulic connections for easier replacement of existing boilers • Digital control panel with wide LCD display with text and symbols clearly showed • Up to 400 litres DHW production in 30’ (ΔT 30°C) any scale formation is blocked thanks to the direct DHW exchange through the plates exchanger
Wide LCD display With dedicated push-buttons for programming and regulation, for a clear display of the information
Hydraulic system
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating 30 lt vitrified stratification cylinder Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Sanitary recirculation option
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Remote controller and climatic regulator (supplied as optional) Control of multi-zones system option
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in the event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Full anti-frost device Anti-legionella function Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge
Combi with DHW storage Fanned flue
Product code
Natural Gas LPG
Open flue
140 Fi
240 Fi
280 Fi
240 i
280 i
CSB
45714351 45714151
45724351 45724151
45728351 45728151
45424351 45424151
45428351 45428151
Maximum heat input
kW
15,3
26,3
30,1
27,1
31,1
Minimum heat input
kW
6,9
11,9
11,9
11,9
11,9
Maximum heat output
kW
14
24,4
28
24,4
28
Minimum heat output
kW
6
10,4
10,4
10,4
10,4
Maximum efficiency
%
90,9
92,9
93,1
90,2
90,6
%
HH 88,3
HHH 90,4
HHH 90,5
HH 89,4
HH 89,5
Energetic efficiency (92/42/CEE) Efficiency at 30%
°C
-5
-5
-5
-5
-5
Expansion vessel/pre-charge
Minimum working temperature
l/bar
7/0,5
7,5/0,5
7,5/0,5
7,5/0,5
7,5/0,5
Heating system max pressure
bar
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/65
35/65
35/65
35/65
35/65
l
30
30
30
30
30
Specific flow according to EN 625
l/min
10,9
14,9
16,7
14,9
16,7
DHW production ∆T 25°C (1)
l/min
8,1
14
16,1
14
16,1
DHW production at discharge ∆T 30°C (1)
l/30’
230
350
400
350
400
bar
8
8
8
8
8
Ø mm
-
-
-
140
140 -
Cylinder capacity
Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100
m
5
4
4
-
Dual flue system Ø 80 max length
m
30
30
30
-
-
Maximum flue mass flow rate
kg/s
0,015
0,017
0,018
0,022
0,024
Minimum flue mass flow rate
kg/s
0,015
0,018
0,018
0,021
0,021
Maximum flue temperature
°C
120
134
142
110
115
Dimensions (h x w x d)
mm
Net weight
kg
63
63
53
53
950x600x466
Gas type Power consumption Grade of protection (1)
63 Natural Gas/LPG
W
190
190
215
140
165
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
Without flow restrictor.
21
Luna3 Silver Space
Technical pages 48-57 65-68 70-72
75
76-77
• Outdoor installation, minimum working temperature: -15°C • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Automatic filling of the heating system • Connection to Baxi integrated solar systems option
Outdoor installation
Automatic filling of the heating system
Ideal for outdoor installation thanks to the minimum working temperature -15°C, grade of protection IPX5D and anti-frost device.
For a perfect managing of the boiler without manual intervention to fill of the system.
Hydraulic system
3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as option) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge
Combi Fanned flue Product code
Natural Gas LPG
CSB
250 Fi
310 Fi
45625367 45625167
45631367 45631167
Maximum heat input
kW
26,9
33,3
Minimum heat input
kW
10,6
11,9
Maximum heat output
kW
25
31
Minimum heat output
kW
9,3
10,4
Maximum efficiency
%
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature Expansion vessel/pre-charge Heating system max pressure
% °C l/bar
92,9
93,1
HHH 90,2
HHH 90,8
-15
-15
8/0,5
8/0,5
bar
3
3
°C
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit DHW production ∆T 25°C
°C l/min
35/60 14,3
35/60 18
Minimum capacity DHW flow rate
l/min
2
2
Minimum pressure on DHW circuit
bar
0,15
0,15
Maximum pressure on DHW circuit
8
Regulation of water temperature in heating circuit
bar
8
Coaxial flue system Ø 60/100
m
5
4
Dual flue system Ø 80 max length
m
40
25
Maximum flue mass flow rate
kg/s
0,017
0,018
Minimum flue mass flow rate
kg/s
0,017
0,019
Maximum flue temperature
°C
135
145
Dimensions (h x w x d)
mm
Net weight
kg
830x550x250 40,5
Gas type Power consumption Grade of protection
22
42 Natural Gas/LPG
W
135
165
IPX5D
IPX5D
Gas boilers
Ecofour
Technical pages 48-57 65-68 70-72
• • • • • •
Control panel Thanks to the control panel with knobs and LCD display, you can easily select temperatures and control the diagnostics.
Ecofour is ideal to be installed in narrow space thanks to its compact dimensions
Combi Fanned flue
Hydraulic system
3 way diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy circulating pump with automatic air vent System to prevent pump and diverter 3 way electric valve operating every 24 hours Heating circuit relief valve set at 3 bar
Efficiency at 30%
Thermoregulation system
Expansion vessel capacity/pre-charge
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge
76-77
Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Hydraulic group made of brass with electric 3 way valve DHW production through stainless steel plate exchanger Full anti-frost device Outdoor sensor option
Compact dimensions
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation(outdoor sensor available as optional)
75
Product code
CSE
Heating only* Open flue
Fanned flue
Open flue
24 F
24
1.24 F
1.14 F
1.24
1.14
46624354
46224354
46524354
46514354
46124354
46114354
Maximum heat input
kW
25,8
26,3
25,8
15,1
26,3
15,4
Minimum heat input
kW
10,6
10,6
10,6
7,1
10,6
7,1
Maximum heat output
kW
24
24
24
14
24
14
Minimum heat output
kW
9,3
9,3
9,3
6,0
9,3
6,0
Maximum efficiency
%
92,93
91,20
92,93
92,50
91,20
90,90
HHH
HH
HHH
HHH
HH
HH
90,37
89,30
90,37
89,80
89,30
88,60
Energetic efficiency (92/42/CEE) Minimum working temperature Maximum capacity of the heating system
% °C
-5
-5
-5
-5
-5
-5
l/bar
6/0,5
6/0,5
6/0,5
6/0,5
6/0,5
6/0,5 100
l
100
100
100
100
100
Heating system max pressure
bar
3
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/60
35/60
5/60
5/60
5/60
5/60
Specific flow according to EN 625
l/min
10.7
10,7
-
-
-
-
DHW production ∆T 25°C
l/min
13,7
13,7
-
-
-
-
Minimum capacity DHW flow rate
l/min
2,0
2,0
-
-
-
-
Maximum pressure on DHW circuit
bar
8
8
-
-
-
-
Flue tube
Ø mm
-
120
-
-
120
110
Coaxial flue system Ø 60/100 max length
m
5
-
5
5
-
-
Dual flue system Ø 80 max length
m
30
-
30
30
-
-
Maximum flue mass flow rate
kg/s
0,014
0,020
0,014
0,012
0,020
0,014
Minimum flue mass flow rate
kg/s
0,014
0,018
0,014
0,012
0,018
0,013
Maximum flue temperature
°C
146
110
149
115
110
99
Dimensions (h x w x d)
mm
Net weight
kg
33
29
28
26
IPX5D
IPX5D
730x400x299
Gas type Grade of protection
32
31
Natural gas/LPG IPX5D
IPX5D
IPX5D
IPX5D
*Heating only models are connectable to UB-UB INOX 80/120 lt. page 31 for sanitary performance.
23
Fourtech
Technical pages 49-57 65-68 70-72
• • • • • • •
Control panel Thanks to the control panel with knobs and LCD display, you can easily select temperatures and control the diagnostics.
Fourtech, distinguished by compact dimensions (730x400x299 mm), is ideal to be installed in narrow space
Combi Fanned flue
3 way electric valve Steel burner Primary exchanger made of copper pipes protected with anti-corrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy circulating pump with automatic air vent System to prevent pump and 3 way electric valve operating every 24 hours Heating circuit relief valve set at 3 bar
Efficiency at 30%
Thermoregulation system
Expansion vessel capacity/pre-charge
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation(outdoor sensor available as optional)
Control system
Overheat limit thermostat to protect primary exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic thermometer Heating circuit pressure gauge
Product code
Natural Gas LPG
CSB
Heating only* Open flue
Fanned flue
Open flue
24 F
24
1.24 F
1.14 F
1.24
1.14
46624368 46624168
46224368 46224168
46524368
46514368
46124368
46114368
Maximum heat input
kW
25,8
26,3
25,8
15,1
26,3
15,4
Minimum heat input
kW
10,6
10,6
10,6
7,1
10,6
7,1
Maximum heat output
kW
24
24
24
14
24
14
Minimum heat output
kW
9,3
9,3
9,3
6,0
9,3
6,0
Maximum efficiency
%
92,93
91,20
92,93
92,50
91,20
90,90
HHH
HH
HHH
HHH
HH
HH
90,37
89,30
90,37
89,80
89,30
88,60
Energetic efficiency (92/42/CEE) Minimum working temperature Maximum capacity of the heating system
% °C
-5
-5
-5
-5
-5
-5
l/bar
6/0,5
6/0,5
6/0,5
6/0,5
6/0,5
6/0,5 100
l
100
100
100
100
100
Heating system max pressure
bar
3
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/60
35/60
5/60
5/60
5/60
5/60
Specific flow according to EN 625
l/min
10.7
10,7
-
-
-
-
DHW production ∆T 25°C
l/min
13,7
13,7
-
-
-
-
Minimum capacity DHW flow rate
l/min
2,0
2,0
-
-
-
-
Maximum pressure on DHW circuit
bar
8
8
-
-
-
-
Flue tube
Ø mm
-
120
-
-
120
110
Coaxial flue system Ø 60/100 max length
m
5
-
5
5
-
-
Dual flue system Ø 80 max length
m
30
-
30
30
-
-
Maximum flue mass flow rate
kg/s
0,014
0,020
0,014
0,012
0,020
0,014
Minimum flue mass flow rate
kg/s
0,014
0,018
0,014
0,012
0,018
0,013
Maximum flue temperature
°C
146
110
149
115
110
99
Dimensions (h x w x d)
mm
Net weight
Kg
33
29
28
26
IPX5D
IPX5D
730x400x299
Gas type Grade of protection
24
76-77
Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Compact hydraulic group with electric 3 way valve DHW production through stainless steel plate exchanger Extractable filter on the CH return circuit to protect the primary exchanger from impurities Full anti-frost device Outdoor sensor option Compact dimensions
Hydraulic system
75
32
31
Natural gas/LPG IPX5D
IPX5D
IPX5D
IPX5D
*Heating only models are connectable to UB-UB INOX 80/120 lt. See page 26 for sanitary performance.
Gas boilers
Mainfour
Technical pages 49-57 65-68 70-72
• • • • • • •
75
76-77
Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Bi-thermic rapid heat exchanger Anti-scale electronic system Full anti-frost device Connection to Baxi integrated solar systems option Outdoor sensor option
Digital control panel The new digital control panel with LCD display and push-buttons makes the boiler’s working check easy and immediate: clear and simple symbols allow to show all boiler’s parameters and anomalies that may occur. Combi Fanned flue
Hydraulic system
Steel burner Bi-thermic rapid heat exchanger made of copper pipes protected with anticorrosion coating Automatic by-pass System to prevent pump sticking operating every 24 hours Heating circuit relief valve set at 3 bar
Thermoregulation system
Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional)
Control system
Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (240F model) Flue thermostat to ensure safe discharge of flue products (24 model) Electronic temperatures control by NTC sensors Full anti-frost device Anti-scale electronic system Electronic thermometer Central heating pressure gauge
Product code
Natural Gas LPG
Openflue
240 F
24
BSE 46624365 46624165
BSB 46224365 46224165
Maximum heat input
kW
25,8
26,3
Minimum heat input
kW
10,6
10,6
Maximum heat output
kW
24
24
Minimum heat output
kW
9,3
9,3
Maximum efficiency
%
92,9
90,6
Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature Expansion vessel capacity/pre-charge
%
HHH
HH
90,2
89,3
°C
-5
-5
l/bar
6/0,5
6/0,5
Heating system max pressure
bar
3
3
Regulation of water temperature in heating circuit
°C
30/85 30/45
30/85 30/45
Regulation of water temperature in DHW circuit
°C
35/55
35/55
DHW production ∆T 25°C
l/min
13,7
13,7
Minimum capacity DHW flow rate
l/min
2
2
Minimum pressure on DHW circuit
bar
0,15
0,15
bar
8
8
Ø mm
-
120 -
Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100 max length
m
5
Dual flue system Ø 80 max length
m
30
-
Maximum flue mass flow rate
kg/s
0,016
0,021
Minimum flue mass flow rate
kg/s
0,016
0,018
Maximum flue temperature
°C
149
120
Dimensions (h x w x d)
mm
Net weight
kg
730x400x299 31
Gas type Power consumption Grade of protection
29 Natural gas/LPG
W
130
80
IPX5D
IPX5D
25
Slim
Technical pages 50-57 65-68 70-72
75
76-77
• Cast iron exchanger • 60 litres stainless steel cylinder (2.300 Fi) • 50 litres cylinder (2.230 i, 2.300 i) • Multifunctional display • Low energy circulating pump (Fi, i models) • System to prevent pump sticking operating every 24 hours • Connection to cylinder option for DHW production (heating only models) Thermoregulation system
Compact dimensions
Built-in climatic regulation (outdoor sensor available as optional) Central heating timer option DHW timer option (DHW production models)
Slim is ideal for installation In compact spaces.
Heating only* Fanned flue 1.230 Fi Product code
WSB
1.230FiN
1.300 Fi
With DHW storage Fanned flue
Open flue 1.300 FiN
1.150 i
1.230 i
1.300 i
1.230 iN
1.300 iN
1.400 iN
1.490 iN
1.620 iN
2.300 Fi
Open flue 2.230 i
2.300 i
43523301 43523347 43530301 43530347 43115301 43123301 43130301 43123347 43130347 43140347 43149347 43162347 43730301 43423301 43430301
Maximum heat input
kW
24,5
24,5
33
33
16,5
24,5
33
24,5
33
44,4
54,1
69
33
24,5
Minimum heat input
kW
13,5
13,5
17
17
9,5
13,5
17
13,5
17
23
27,5
35
17
13,5
17
Maximum heat output
kW
22,1
22,1
29,7
29,7
14,9
22,1
29,7
22,1
29,7
40
48,7
62,2
29,7
22,1
29,7
Minimum heat output
kW
11,8
11,8
14,9
14,9
8,5
11,8
14,9
11,8
14,9
20,6
24,5
31,6
14,9
11,8
14,9
Maximum efficiency
%
90
90
90,3
90,3
90,3
90,2
90
90,2
90
90,1
90
90,1
90,3
90,2
90
%
HH 89,6
HH 89,6
HH 88,8
HH 88,8
HH 88,2
HH 88,5
HH 88,5
HH 88,5
HH 88,5
HH 88,8
HH 88,4
HH 88,9
HH 88,8
HH 88,5
HH 88,5
4
4
5
5
3
4
5
4
5
6
7
9
5
4
5
l
11,8
11,8
14,6
14,6
9
11,8
14,6
11,8
14,6
17,4
20,2
25,8
14,6
11,8
14,6
Expansion vessel/pre-charge
l/bar
10/1
-
10/1
-
10/1
10/1
10/1
-
-
-
-
-
10/1
10/1
10/1
Heating system max pressure
bar
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Energetic efficiency (92/42/CEE) Energetic efficiency 30% Cast irons sections Cast irons boiler water capacity
Regulation of heating water temperature Cylinder temperature regulation
33
°C
30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45
°C
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
5/65
DHW production ∆T 35°C
l/min
-
-
-
-
-
-
-
-
-
-
-
-
12,2
9
12,1
DHW production at discharge ∆T 30°C
l/30’
-
-
-
-
-
-
-
-
-
-
-
-
485
366
475
Maximum pressure on DHW system
bar
-
-
-
-
-
-
-
-
-
-
-
-
8
8
8 140
Flue tube
Ø mm
-
-
-
-
110
130
140
130
140
160
160
180
-
130
Coaxial flue system Ø 60/100 max length
m
5
5
5
5
-
-
-
-
-
-
-
-
5
-
-
Dual flue system Ø 80 max length
m
20
20
20
20
-
-
-
-
-
-
-
-
20
-
-
mm
850 350 600
850 350 600
850 350 600
850 350 600
850 350 520
850 350 600
850 350 680
850 350 600
850 350 680
850 350 635
850 350 715
850 350 875
850 650 600
850 650 600
850 650 600
kg
121
111
144
134
89
113
136
103
126
150
174
224
184
155
176
Dimensions
Net weight
height width depth
Gas type Power consumption Grade of protection
Natural gas/LPG W
170
70
170
70
120
120
120
15
15
15
15
15
170
120
120
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
IPX4D
* Heating only models are connectable to Slim UB-UB INOX 80/120 lt. See page 31 for sanitary performance.
26
Gas floor standing boilers
Slim HP
Technical pages
• • • •
50
75
Body composed by pre-assembled cast iron elements properly designed to optimize the efficiency Stainless steel two-stage atmospheric burner and gas valve 50 mm fiberglass insulation Flue safety thermostat
Control panel Very user friendly control panel which incorporates full safety features, including control and high limit thermostats, thermometer, and burner on/off switch.
Easy mounting of cast-iron elements Safe lightening by intermittent pilot ignition Weather compensated central (cascade installations) Connection to an indirect cylinder option Cascade installation option
Heating only Open flue 1.830 iN
1.990 iN
1.1160 iN
WSO
43108360
43109960
43111660
Power output Power output first stage 60% Power input Power input first stage 60%
kW kW kW kW
82.8 49.7 90 54
99.4 59.6 108 64.8
115.9 69.5 126 75.6
Nominal efficiency Number of elements Number of burners
%
92 6
92 7
92 8
5
6
7
35 5
40 5
44 5
202
202 0.5
252
9.5
11.4
13.3
Product code
Number of burner injectors Water content of the cast-iron body Maximum pressure in the heating circuit
bar
Flue (outside)
Ø Ø
Pilot burner injector G20 Natural gas 20 mbar
Propane gas 37 mbar
G20
Flow rate m³/h 15°C 1013 mbar Pressure at injectors
mbar
Injector mark Flue temperature CO2 Flue flow rate at design rate Pilot burner injector Injector mark Flow rate 15°C 1013 mbar G31 Pressure at injectors
Design rate (Qn) 60%
6
100%
16.5 °C % kg/h Ø
Design rate (Qn) mbar
134 6 235.4
7 60% 100%
320 W 148 7 243.2 0.3 215 Y 8.4
125 5 358.7
9.8
14.5 35
* with antirefouler These models are connectable to indirect cylinders. See pages 33-35.
27
Solar systems
28
Collectors for forced draft installation
29
Solar systems Technical pages
58
Collectors for forced draft installation
SB 25+V/O, SB 20+V/O, SB 100
• Gross surface: 2,51 m² (SB25+V/O), 2,01 m² (SB20+V/O ), 10,05 m2 (SB100) • Meander pipes for a better heat transmission (SB20+,SB25+) • Installation on a pitched, flat built in roof • Solutions for groups from 3 to 7 people • Hydraulic group with electronic regulation available as optional • Connection to the range of cylinders from 200 to 3000 lt, single or double coil option
Product code Gross surface Absorber area Aperture area Collector capacity Maximum working pressure Maximum working temperature ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses
SVB 26
Collectors SB20+V SB20+O 61520430 61520330 2,01 2,01 1,88 1,88 1,9 1,9 1,87 2,16 10 10 212,8 211
LSC m² m² m² lt bar °C
SB25+V 61525430 2,51 2,35 2,37 2,3 10 211
SB25+O 61525330 2,51 2,35 2,37 2,7 10 211
%
82,1
82,5
79,2
W/m²k² W/m²k²
3,67 0,0090
3,549 0,0123
4,085 0,016
SB21+ 61521430 2,01 1,88 1,89 1,52 10 200
SB100 61501010 10,05 9,17 9,43 9 10 192
80,6
76,1
78,9
3,83 0,018
4,33 0,009
3,834 0,011
• Gross surface: 2,57 m2 • Absorption capacity 96% • Type of covering: vacuum tubes sidney type with boronsilicate glass and highly selective internal layer
Product code Gross surface Absorber area Aperture area Collector capacity Maximum working pressure ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses
Collector SVB26 61527010 2,57 2,36 2,23 2,27 10
LSC m² m² m² lt bar %
60,5
W/m²k² W/m²k²
0,85 0,01
* data based on an average temperature of the heat transfer fluid
Collectors for natural draft installation SB 21+
• Gross surface 2,01 m2 • One collector (SB 21+) solution with 150 or 200 liters capacity cylinder • Two collectors (SB 21+) solution with 300 liters capacity cylinder • Installation on flat or pitched roof
Product code Collector Gross surface Absorber area Aperture area Collector capacity Cylinder capacity Maximum working pressure Maximum working temperature ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses
LSC
STS-150L 69000100 1
m² m² m² lt l bar °C
150
Collector STS-200L 69000101 1 2,01 1,88 1,89 1,52 200 10 200
%
76,1
W/m²k² W/m²k²
4,33 0,009
STS- 300L 69000102 (flat roof) 69000103 (pitched roof) 2
300
29
Indirect cylinders
Indirect cylinders
30
- UB - UB inox - Slim - Slim UB inox - Combi 80 lt - Indirect cylinders
31 31 32 33
Indirect cylinders
UB - UB inox
Technical pages
59
78
• 80/120 lt indirect cylinder available in stainless steel AISI 316L or coated steel • Magnesium anode for anticorrosion protection • Nipples in the fixing template • Indirect cylinder temperature controlled directly on the boiler’s control panel
UB Product code 80 Product code 120
Condensig boilers KSG 71403171 KSG 71403181
Cylinder Capacity
Gas boilers
12 kW WH boiler 24 kW WH boiler 28 kW WH boiler 25 kW WH boiler 24 kW WH boiler 31 kW WH boiler 18 kW WH boiler 14 kW WH boiler + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120
l
80/120
80/120
80/120
80/120
80/120
80/120
80/120
DHW production ∆T 25°C in continuous
l/min
6,9
13,8
16,1
14,3
13,7
18
10
8
DHW production ∆T 30°C at discharge
l/30 min
270/330
430/480
480/530
440/490
430/480
490/540
340/390
290/350
bar
8
8
8
8
8
8
8
8
Maximum pressure DHW system UB INOX Product code 80 INOX Product code 120 INOX
Condensig boilers KSG 71408441 KSG 71408451
Cylinder Capacity
80/120
Gas boilers
12 kW WH boiler 24 kW WH boiler 28 kW WH boiler 25 kW WH boiler 24 kW WH boiler 31 kW WH boiler 18 kW WH boiler 14 kW WH boiler + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120
l
80/120
80/120
80/120
80/120
80/120
80/120
80/120
DHW production ∆T 25°C in continuous
l/min
6,9
13,8
16,1
14,3
13,7
18
10
8
DHW production ∆T 30°C at discharge
l/30 min
270/330
430/480
480/530
440/490
430/480
520/570
340/390
290/350
bar
8
8
8
8
8
8
8
8
Maximum pressure DHW system
80/120
Slim UB - Slim UB inox • 80/120 lt indirect cylinder available in stainless steel AISI 316L or coated steel • Magnesium anode for anticorrosion protection • Nipples in the fixing template • Indirect cylinder temperature controlled directly on the boiler’s control panel
SLIM UB Product code 80 Product code 120
Gas boilers KSW 71412241 KSW 71412251
Cylinder Capacity
14,9 kW FS boiler + UB 80/120
22,1 kW FS boiler + UB 80/120
29,7 kW FS boiler + UB 80/120
40 kW FS boiler + UB 80/120
48,7 kW FS boiler + UB 80/120
62,2 kW FS boiler + UB 80/120
80/120
l
80/120
80/120
80/120
80/120
80/120
DHW production ∆T 25°C in continuous
l/min
8,5
12,7
17
19,5
19,5
19,5
DHW production ∆T 30°C at discharge
l/30 min
300/360
400/450
490/550
490/610
490/610
490/610
bar
8
8
8
8
8
8
14,9 kW FS boiler + UB 80/120
22,1 kW FS boiler + UB 80/120
29,7 kW FS boiler + UB 80/120
40 kW FS boiler + UB 80/120
48,7 kW FS boiler + UB 80/120
62,2 kW FS boiler + UB 80/120
80/120
Maximum pressure DHW system SLIM UB INOX Product code 80 INOX Product code 120 INOX
Gas boilers KSW 71408781 KSW 71408791
Cylinder Capacity
l
80/120
80/120
80/120
80/120
80/120
DHW production ∆T 25°C in continuous
l/min
8,5
12,7
17
19,5
19,5
19,5
DHW production ∆T 30°C at discharge
l/30 min
300/360
400/450
500/550
570/620
570/620
570/620
bar
8
8
8
8
8
8
Maximum pressure DHW system
31
Combi 80 lt
Technical pages 45-57 65-68 70-72 76-77
• • •
80 lt stainless steel AISI 316L indirect cylinder Magnesium anode for anticorrosion protection Easy connection to heating only wall hung boilers for a free standing installation
Product code KSL 71408471
Luna3 Comfort + Combi
+
=
1.240 Fi - 1.310 Fi - 1.240 i models
Luna3 Comfort 1.240 Fi Stainless steel cylinder capacity
1.310 Fi
1.240 i
l
80
80
80
°C
35/60
35/60
35/60
DHW production ∆T 25°C in continuous
l/min
14,3
18
13,7
DHW production ∆T 30°C at discharge
l/30 min
420
520
420
Maximum recovering time of the cylinder
min
8
3
8
Maximum pressure DHW system
bar
8
8
8
Cylinder DHW temperature regulation
32
Indirect cylinders
Indirect cylinders
Technical pages 59-60
• Enamelled steel indirect cylinders • DHW sensor for indirect cylinder available as option • It is necessary to install the optional 3 way valve motor (KHG 714106610 ) for connection to Luna3 and Luna3 Comfort models. • It is necessary to use specific kit (KHG 714096311 ) with electric 3 way valve for connection to Ecofour, Fourtech
.
.
DHW indirect cylinders
UB 200 SC/DC Product code
SC DC
LSC
Cylinder capacity
71520701 71520801
lt
200
Insulation Coil
UB 200 SC/DC
polyurethane SC DC
single double
Insulation thickness
mm
50
Working maximum pressure
bar
8
Working maximum pressure in the coil
bar
8
Upper coil thermal exchange (DC)
kW
20
Lower coil thermal exchange (SC/DC)
kW
27
Weight
kg kg
95 107
mm
1275x600
SC DC
Dimensions HxØ
DHW indirect cylinders with wider exchange surface
Product code
SC+ DC+
Cylinder capacity
UB 300 SC+/DC +*
UB 400 SC+/DC +*
71003701 71003801
71004701 71004801
LSC lt
Insulation Coil
400 polyurethane
single double
single double
SC DC
Insulation thickness
mm
50
50
Working maximum pressure
bar
10
10
Working maximum pressure in the coil
bar
10
10
Upper coil thermal exchange (DC)
kW
30
30
Lower coil thermal exchange (SC/DC)
kW
45
55
Weight
kg kg
118 135
144 161
mm
1797x600
1780x700
SC DC
Dimensions HxØ
UB 300 SC+/DC+
300 injection polyurethane
UB 400 SC+/DC+
Stainless steel cylinders for DHW production
Product code Cylinder capacity
UBSS 250 DC
UBSS 260 SC
LSC
71525801
71525701
lt
250
260
polyurethane foam
polyurethane foam
Insulation
double
single
Insulation thickness
Coil mm
45
45
Working maximum pressure
bar
10
10
Working maximum pressure in the coil
bar
10
10
Upper coil thermal exchange (DC)
kW
20
-
Lower coil thermal exchange (SC/DC)
kW
27,8
27,8
Weight
kg
58
48
Dimensions HxØ
mm
1743x545
1804x545
UBSS SC/DC 33
Technical pages 59-60
Cylinders for DHW production for solar integration
UB 200 SOLAR Product code Cylinder capacity
KSL lt
Coil
71413521 200 single
Working maximum pressure
bar
8
Working maximum pressure in the coil
bar
6
Coil thermal exchange (∆T=30° C)
kW
20
Weight
kg
145
Dimensions (h x w x d)
mm
1500x600x640
LSC
71003821
UB 200 SOLAR
• Vitrified steel DHW cylinder with single coil exchanger for solar integration • To be connected to any combi boiler • Mixing valve and diverter valve supplied with the cylinder • Solar circulating group supplied with the cylinder • DHW expansion vessel – 8 lt capacity – supplied with the cylinder • Solar expansion vessel – 18 lt capacity – supplied with the cylinder
Cylinders for DHW production with solar circulating group
UBSI 300 Product code Cylinder capacity
lt
Insulation Coil
• cylinder • hydraulic group • expansion vessel
UBSI 300
34
300 injection polyurethane double
Insulation thickness
mm
55
Working maximum pressure
bar
10
Working maximum pressure in the coil
bar
10
Upper coil thermal exchange
kW
18,5
Lower coil thermal exchange
kW
37,5
Weight
kg
135
Dimensions HxØ
mm
1706x610
Indirect cylinders Enamelled steel cylinders for DHW production
UB 500 DC
UB 800 DC
Product code
SC DC
UB 1000 SC/DC
lt
Insulation SC DC
Insulation thickness
UB 800 DC
71005801 500
UB 2000 SC/DC
mm
UB 3000 SC UB 1500 DC
71008801
UB 1000 SC/DC 71010701 71010801
UB 3000 SC 71030701
71015801
UB 2000 SC/DC 71020701 71020801
800
1000
injection polyurethane
polyurethane stiff bowls
soft polyurethane
1500
2000
3000
soft polyurethane
soft polyurethane
soft polyurethane
double
double
single double
double
single double
50
double
85
100 (SC) 85 (DC)
100
100
100
LSC
Cylinder capacity
Coil
UB 1500 DC
UB 500 DC
Technical pages 59-60
Working maximum pressure
bar
10
10
10
10
10
10
Working maximum pressure in the coil
bar
10
10
10
10
10
10
Upper coil thermal exchange (DC)
kW
30
37
45 60 (DC)
63
74
-
Lower coil thermal exchange (SC/DC)
kW
60
60
63 (SC)
107
115
134
Weight
kg kg
174
235
206 243
386
465 465
670
mm
1780x760
1905x990
2120x940 (SC) 2155x990 (DC)
2285x1200
2550x1300
2980x1400
SC DC
Dimensions HxØ
Cylinders for DHW production and integration with solar systems on the heating circuit
UBTT 1000 Product code Cylinder capacity
UBPT 1000 LSC DHW Heating
Insulation Cylinder Coil
UBPT 2000
UBPU 1500 SC
UBTT 1000
UBPT 1000
UBPT 2000
UBPU 1500
71010501
71010601
71020601
71015302
220 780
1000
2000
1500
soft polyurethane
soft polyurethane
soft polyurethane
soft polyurethane
tank in tank
pipe in tank
pipe in tank
buffer
single (SC)
double (DC)
double (DC)
single (SC) 100
Insulation thickness
mm
100
120
120
Working maximum pressure
bar
3
3
3
3
Working maximum pressure in the coil
bar
10
10
10
10
Upper coil thermal exchange
kW
n.a.
97
135
n.a.
Lower coil thermal exchange
kW
69
97
177
89
Weight
kg
245
210
325
230
Dimensions HxØ
mm
2090x990
2110x1030
2380x1340
2150x1300
35
Waters heaters
Electric waters heaters
Gas storage waters heaters
36
37 37
Water heaters
Electric water heaters
Technical pages 61-62
77
• Polystyrene insulation (10-15 lt) • Polyurethane insulation (30-100 lt) • 40% energy saving • Steel water tank coated with titanium enamel vitrified at 900°C • Magnesium anode • RoHS-WEEE Compliant • Grade of protection: IPX4
Product code Capacity Installation Rating/voltage Adjustable thermostat Height Width Depth
Product code Capacity Installation Connection Rating/voltage Adjustable thermostat Thermometer Height Width Depth
Product code Capacity Installation Connection Rating/voltage Adjustable thermostat Thermometer Height Width Depth
RSA l W/V mm mm mm
ASA l
W/V
mm mm mm
ASA l
W/V
mm mm mm
SR 501 31501811 10 above sink 1.200/230 internal 432 267 250 SV 530 31503811 30 upright 1.200/230 internal 542 340 SV 510 TD 31510715 100 upright right 1.500/230 internal • 920 440
SR 501 CR 31501252 10 above sink 1.200/230 external 432 267 250 SV 530 R 31503252 30 upright 1.200/230 external 542 340 SV 510 TS 31510716 100 upright left 1.500/230 internal • 920 440
SR 501 SL 31501821 10 under sink 1.200/230 internal 432 267 250
SV 550 31505215 50 upright 1.200/230 internal • 520 440
SR 501 CR SL 31501262 10 under sink 1.200/230 external 432 267 250
SV 580 31508215 80 upright 1.200/230 internal • 760 440
SO 580 31508217 80 horizontal 1.200/230 internal • 760 440
SV 510 31510215 100 upright 1.500/230 internal • 920 440
SO 510 31510217 100 horizontal 1.500/230 internal • 920 440
SR 515 31502811 15 above sink 1.200/230 internal 432 350 310 SV 550 TD 31505715 50 upright right 1.200/230 internal • 520 440
SO 580 TD 31508714 80 horizontal right 1.200/230 internal • 760 440
SR 515 CR 31502252 15 above sink 1.200/230 external 432 350 310
SV 550 TS 31505716 50 upright left 1.200/230 internal • 520 440
SO 580 TS 31508718 80 horizontal left 1.200/230 internal • 760 440
SV 580 TD 31508715 80 upright right 1.200/230 internal • 760 440 SO 510 TD 31510714 100 horizontal right 1.500/230 internal • 920 440
SR 515 SL 31502821 15 under sink 1.200/230 internal 432 350 310 SV 580 TS 31508716 80 upright left 1.200/230 internal • 760 440 SO 510 TS 31510718 100 horizontal left 1.500/230 internal • 920 440
Gas storage water heaters • Porcelain enamel vitrified steel boiler to ensure long-lasting product • Adjustable thermostat • Magnesium anode • Wall hung or floor standing installation
WALL HUNG Product code Capacity
ASB lt
FLOOR STANDING
SAG2 50
SAG2 80
SAG2 100
SAG2 125 T
SAG2 155 T
SAG2 195 T
SAG2 300 T
311053130 • 50
311083130 • 80
311103130 • 100
311123140 • 125
311153140 • 155
311193140 • 195
311303140 • 300 17,4
Maximum heat input
kW
4,2
5,8
5.8
7,5
8,5
9
Maximum heat output
kW
3,49
4,82
4,82
6,3
7,2
7,8
14,6
DHW temperature regulation
°C
40-70
40-70
40-70
40-70
40-70
40-70
40-70
l/min
1,7
2,3
2,3
3,0
3,4
3,7
6,9
•
•
•
•
•
•
•
Nat. Gas/LPG
Nat. Gas/LPG
Nat. Gas/LPG
Nat. Gas/LPG
Nat. Gas/LPG
Nat. Gas/LPG
Nat. Gas/LPG
DHW flow rate ΔT 30°C Thermostat Gas type Thermometer
•
•
•
-
-
-
-
Height
mm
613
863
983
1250
1420
1730
1700
Diameter
mm
450
450
450
520
520
520
600
37
Technical Section
38
Technical drawings Graphs Flue systems
39
Flue pipe accessories
63
Hydraulic accessories
70
Thermoregulation accessories
73
Other accessories
77
Products technical data
79
Technical drawings Graphs Flue systems
Condensing gas boilers Gas boilers Flue systems Solar collectors Indirect cylinders Electric water heaters Gas water heaters
40 44 51 58 59 61 62
39
Condensing gas boilers A69
HEAD mH2O
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections
Luna Platinum 177
max min
B 686
Luna Platinum 24, 33, 1.12, 1.18, 1.24, 1.32
FLOW RATE (l/h)
50 45
179 A69
max min
FLOW RATE (l/h)
50 45
179
40
HEAD mH2O
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections
Luna Duo-tec 177
B 686
Luna Duo-tec 24, 28, 33, 40, 1.12, 1.24, 1.28
Technical drawings - graphs - flue systems
Condensing gas boilers Duo-tec Compact 24, 1.24
Duo-tec Compact
400 238
FLOW RATE (l/h)
70
40 30
105 162
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections
B 686
A69
299
Duo-tec Max
Duo-tec Max 24, 33 A69
HEAD mH2O
177
max min
B 686
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections
HEAD mH2O
124
FLOW RATE (l/h)
50 45 179
41
Condensing gas boilers Nuvola Platinum
Nuvola Platinum 24, 33
181
HEAD mH2O
1 2 3 4 5 SC
156,5
DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4” Condensing trap possible to connect on a pipe Ø21
MAX MIN
FLOW RATE (l/h)
117,5
100
110
100
110
62,5
SC
bottom view
Nuvola Duo-tec
Nuvola Duo-tec 16, 24
181
HEAD mH2O
1 2 3 4 5 SC
156,5
DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4” Condensing trap possible to connect on a pipe Ø21
FLOW RATE (l/h)
117,5
100
110
100
110
SC
bottom view
42
max min
62,5
Technical drawings - graphs - flue systems
Condensing gas boilers Luna3 Comfort HT Solar - heating system circuit
600
HEAD mH2O
Luna3 Comfort HT Solar 120, 120 MS, 240, 240 MS 640 600
433,5
273
273
415
I speed.
H
89
I L
FLOW RATE (l/h)
103
95 130 130 E F G A B C D
2056
III speed. II speed.
760 832
190 65105
Luna3 Comfort HT Solar
9085 95 90
HEAD mH2O
95
frontal view
side view
I speed.
back view
A DHW relief valve outlet G 1/2” B Mains water G 1/2” C DHW recirculation G 1/2” D DHW outlet G 1/2” E Heating system flow G 3/4”
F Gas supply pipe G 3/4” G Heating system return G 3/4” H Solar relief valve outlet G 1/2” I Collector inlet G 3/4” L Collector outlet G 3/4”
III speed. II speed.
FLOW RATE - Solar circuit
Hybrid Systems Prevalenza
HEAD mH2O
Luna Platinum CSI 33
70 70
65
2
65
850
1
70 70 70 70
frontal view
72
856
672
back view
side view
Portata FLOW RATE Q (l/h)
HEAD mH2O
65
Prevalenza
65
2
Portata FLOW RATE Q (l/h)
Example : pump head 2nd zone with half-open mixing valve
HEAD mH2O
1
Prevalenza
868
Prevalenza
80 80 80 80 80 80 80 80 80 80 80 80 80
70 70
152
2060
70 70
HEAD mH2O
Portata FLOW RATE Q (l/h)
Zonazone 1 portata 0 rate 0 III 1st flow Zonazone 1 portata 500 l/h 500 l/h II 1st flow rate Zonazone 1 portata 1000 l/h 1000 l/h I 1st flow rate
Portata FLOW RATE Q (l/h)
43
Gas boilers Luna3 Comfort 240 i, 1.240 i
Luna3 Comfort 310 Fi - 1.310 Fi
HEAD mH2O
Luna3 Comfort 240 Fi, 310 Fi, 1.240 Fi, 1.310 Fi
FLOW RATE (l/h)
HEAD mH2O
Luna3 Comfort 240 i - 1.240 i - 1.240 Fi - 240 Fi
FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 425 mm B Distance between hanging points and hydraulic connection
Luna3 240 i
188 100
Luna3 310 Fi - 1.310 Fi - 280 Fi - 240 Fi - 240 i
HEAD mH2O
Luna3 240 Fi, 280 Fi, 310 Fi, 1.310 Fi
FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 425 mm B Distance between hanging points and hydraulic connection
44
Technical drawings - graphs - flue systems
Gas boilers Luna3 Comfort Air 250 Fi, 310 Fi HEAD mH2O
Luna3 Comfort Air 250 Fi - 310 Fi
FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 425 mm B Distance between hanging points and hydraulic connection
Luna3 Comfort + Combi 240 Fi, 310 Fi HEAD mH2O
Luna3 Comfort + Combi 240 Fi - 310 Fi
FLOW RATE (l/h)
frontal view
A B C E F G I
side view
back view
view from above
Heating system flow G 3/4” M Heating system return G 3/4” M Gas supply pipe G 3/4” M Mains water G 1/2” M DHW outlet G 1/2” M DHW recirculation G 1/2” M Relief valve outlet
45
Gas boilers Luna3 Blue 180 i - 1.180 i - 240 i
Luna3 Blue 180 i, 240 i, 1.180 i
188 100
C
HEAD mH2O
Luna3 Blue 240 Fi, 280 Fi, 1.240 Fi
III speed.
II speed. FLOW RATE (l/h)
HEAD mH2O
Luna3 Blue 240 Fi - 1.240 Fi
III speed. II speed. FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”
A B C
Boiler hanging points. Distance between hanging points: 425 mm Distance between hanging points and hydraulic connection Ø 110: 180 i – 1.180 i Ø 130: 240 i
HEAD mH2O
Luna3 Blue 280 Fi
I speed. FLOW RATE (l/h)
Luna3 Comfort Max 240 i
Luna3 Comfort Max 310 Fi
HEAD mH2O
Luna3 Comfort Max 250 Fi, 310 Fi
III speed. II speed.
I speed.
III speed. II speed.
FLOW RATE (l/h)
HEAD mH2O
Luna3 Comfort Max 240 i - 250 Fi
II speed. FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”
46
A B
Boiler hanging points. Distance between hanging points: 425 mm Distance between hanging points and hydraulic connection
III speed.
Technical drawings - graphs - flue systems
Gas boilers Nuvola3 Comfort 240 i, 280 i
Nuvola3 Comfort 140 Fi - 240 Fi/i
HEAD mH2O
Nuvola3 Comfort 140 Fi, 240 Fi, 280 Fi, 320 Fi
Ø100
FLOW RATE (l/h)
HEAD mH2O
Nuvola3 Comfort 280 Fi/i - 320 Fi
FLOW RATE (l/h)
1 2 3 4 5
DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4”
bottom view
Nuvola3 BS 240 i, 280 i
Nuvola3 BS 140/240
HEAD mH2O
Nuvola3 BS 140 Fi, 240 Fi, 280 Fi
Ø100
FLOW RATE (l/h)
Nuvola3 BS 280
6
HEAD mH2O
5 4 3 2 1 0
FLOW RATE (l/h)
1 2 3 4 5
Heating system flow G 3/4” DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Gas inlet G 3/4”
bottom view
47
Gas boilers Luna3 Silver Space 250 Fi, 310 Fi HEAD mH2O
Luna3 Silver Space 250 Fi - 310 Fi
FLOW RATE (l/h)
MR Heating system flow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 524 mm B Distance between hanging points and hydraulic connection
Ecofour 24 F, 1.14 F, 1.24 F
Ecofour 24, 1.14, 1.24
EcoFour
HEAD mH2O
400
400
162
122
Ø120 (24 kW) Ø110 (14 kW)
FLOW RATE (l/h)
B 680
B 680
730
730
A 23
A 23
Ø100
70
65 65
65
70 65
70
9 14 5,5 2,5
MR Heating system fl ow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”
48
1
A B
65 65
65
65
70
95
,5
Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection
Technical drawings - graphs - flue systems
Fourtech 24 F, 1.14 F, 1.24 F
Fourtech 24, 1.14, 1.24 400
400
Fourtech
Ø120 (24 kW) Ø110 (14 kW)
A 23
A 23
Ø100
HEAD mH2O
162
122
B 680
B 680
730
730
FLOW RATE (l/h)
65
70 65
70
9 14 5,5 2,5
MR Heating system fl ow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”
A B
Mainfour 240 F
65 65
65
65
70
9 14 5,5 2,5
Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection
Mainfour 24 400
400
MainFour 24 162
122
Ø100 A 23
A 23
Ø120
HEAD mH2O
70
65 65
70
65
65
65
65
MainFour 240F
70
70
9 14 5,5 2,5
MR Heating system fl ow G 3/4” US DHW outlet G 1/2” GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”
65 65
70 65 65
9 14 5,5 2,5
A B
HEAD mH2O
B 680
B 680
730
730
FLOW RATE (l/h)
FLOW RATE (l/h)
Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection
49
Gas boilers Slim 1.230 Fi, 1.300 Fi
HEAD mH2O
542 - 622 520 - 600
116 119 115
520 - 600
350
Slim 2.300 Fi - 2.230 i - 2.300 i - 1.150 i 1.230 i - 1.300 i - 1.230 Fi - 1.300 Fi
Slim 1.230 FiN, 1.300 FiN
A
A C
850
C
I speed.
III speed.
II speed.
0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4
FLOW RATE (l/h)
B 481 - 564 596 - 676
frontal view
side view
back view
Slim 1.150 i, 1.230 i, 1.300 i
A Heating system flow G 3/4” M B Heating system return G 3/4” M C Gas supply pipe G 1/2” M
481 - 561 507 - 587
B
side view
Slim 1.230 iN, 1.300 iN
back view
Slim 1.400 iN, 1.490 iN, 1.620 iN
L1
Slim 1.150i Slim 1.230i, 1.230iN Slim 1.300i, 1.300iN
520 600 680
dimensions (mm)
L1
Slim 1.400iN Slim 1.490iN Slim 1.620iN
H
L2
1490 1490 1650
635 715 875
dimensions (mm) L2
frontal view
side view
frontal view
Slim 2.300 Fi
side view
back view
Slim 2.230 i, 2.300 i
back view
back view
side view
frontal view
A Heating system flow G 3/4” M B Heating system return G 3/4” M C Gas supply pipe G 1/2” M D Mains water G 1/2” M E DHW outlet G 1/2” M F Recirculation G 1/2” M (Slim 2.260 Fi) Recirculation G 1/2” F (Slim 2.230 i, 2.300 Fi)
Slim HP 1.830 iN, 1.990 iN, 1.1160 iN 1190 B
Number of elements
C 910 Flow outlet 51
45
Ø E
263
Gas inlet
D 874
1004
874
612
699
1100
1100
1160
C
mm
975
975
1000
D
mm
1003
1003
1013
202
202
252
E (outside)
Ø
Blackflow
Ø
Rp 1” ½
Outlet -inlet of gas
Ø
Rp 1” ½
Weight
143
243
50
Bleed tap Ø 1/2
485 60
807
8
537
mm
ΔP to Δt 15
A
7
mm
B
Water content Back outlet
6
A
mbar
31
41
l
35
40
53 44
Kg
330
375
415
Technical drawings - graphs - flue systems
Coaxial flue system Luna Platinum, Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Platinum, Nuvola Duo-tec, Luna3 Comfort HT Solar
L max= 10 m 25 m
n Ø 60/100 mm n Ø 80/125 mm
L max= 10 m 25 m
L max= 10 m 25 m
L max= 9 m 24 m L max= 10 m 25 m
998
998
345
L max= 10 m 25 m
345
405
998
345
998
L max= 9 m 24 m
L max= 10 m 25 m
L max= 9 m 24 m
L max= 8 m 23 m LAS chimney
Tubes maximum length (m) Ø 60/100
Ø 80/125
10
25
Length reduction for a 45° bend insertion (m)
1
0,5
Duo-tec Compact
Luna Platinum - Luna Duo-tec Duo-tec Max
238
140,5
124
131 min
131 min
177
Length reduction for a 90° bend insertion (m)
450
345
frontal view
side view
400 frontal view
Nuvola Platinum - Nuvola Duo-tec
Luna3 Comfort HT Solar 273
433,5
112 min
119
171 side view
side view
156,5
181
466
299
600 frontal view
600
640
frontal view
side view
51
Coaxial flue system Luna3 Comfort - Luna3 Comfort + Combi - Luna3 - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max - Luna3 Silver Space - Ecofour - Fourtech - Mainfour L max
L max
L max
L max
L max
L max
405
345
998
345
998
345
998
998
LAS chimney
L max
L max
L max
L max
Lmax can change according to the flue type and boiler models. See the instruction manual.
Horizontal flue Vertical chimney
Ø 60/100
Ø 80/125
5 4 4 5 4 4 4
9 8 - 10 -
Luna3 24/25 kW Luna3 28/31 kW Luna3 Blue Ecofour - Fourtech - Mainfour Luna3 Luna3 Blue Ecofour - Fourtech - Mainfour
Luna3 Comfort - Luna3 Comfort Air Luna3 Blue - Luna3 Comfort Max - Eco3
100
450
0,5
345
450
550
frontal view
side view
114
122
400
299
frontal view
side view
Luna3 Silver Space
398
side view
Ecofour - Fourtech - Mainfour
52
1
Luna3 Comfort + Combi
188
frontal view
Length reduction for a 45° bend insertion (m)
143 min
143 min
100
Length reduction for a 90° bend insertion (m)
100
143 min
Tubes maximum length (m)
226
76
324
frontal view
250
side view
Technical drawings - graphs - flue systems
Nuvola3 Comfort - Nuvola3 BS
n Ø 60/100 mm n Ø 80/125 mm
L max= 4 m 8m
L max= 4 m 8m
L max= 4 m 8m
L max= 3 m 7m L max= 3 m (320 Fi)
L max= 4 m 8m
L max= 3 m 7m L max= 2 m (320 Fi)
L max= 3 m (320 Fi) LAS chimney
998
998
345
345
345
405
998
998
L max= 3 m (320 Fi)
L max= 4 m 10 m
L max= 4 m 10 m
L max= 3 m 9m
L max= 2 m 8m
Tubes maximum length (m) 100
150
120 min.
Horizontal
600
466
frontal view
Ø 80/125
24/28 kW
4
8
flue
14 kW
5
8
32 kW
3
8
4
10
Vertical chimney
side view
Ø 60/100
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
1
0,5
Slim L max= 3 m
L max= 4 m
L max= 5 m
LAS chimney L max= 4 m
L max= 3 m
L max= 3 m
345
345
998
998
998 405
345
998
L max= 3 m
L max= 3 m L max= 3,5 m L max= 4 m
L max= 4 m
Slim 1.230 Fi/FiN, 1.300 Fi/FiN
Slim 2.300 Fi 100
above view
234
Tubes maximum length (m)
100
100 116
102 min.
234
102 min. 102 min.
102 min.
100
416
side view
above view
5
Length Length reduction reduction for a 90° for a 45° bend insertion bend insertion (m) (m) 1
0,5
Ø flue mm
60 - 100
side view
53
Dual flue system Luna Platinum, Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Platinum, Nuvola Duo-tec, Luna3 Comfort HT Solar L1 = FLUE PIPE / L2 = INTAKE PIPE L1
500 1150
1150 500
L2
15
14
(L1 + L2) max = 80 m L2 max = 15 m
Tubes maximum length (m)
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
Installation with terminal Ø 60
30
3
1,25
Installation with terminal Ø 80
80
0,5
0,25
Installation with chimney terminal
15
0,5
0,25
Luna Platinum - Luna Duo-tec Duo-tec Max 110
110
140,5
159
177 450
345
frontal view
side view
Nuvola Platinum - Nuvola Duo-tec 191
94
110
177
140,5
450 frontal view
side view
with adjustable dual flue kit 110 120 110
181
181
148
188
110 89 110
120
134
120
198
110
with adjustable dual flue kit
156,5 600
466
600
frontal view
side view
frontal view
Duo-tec Compact
side view
Luna3 Comfort HT Solar 124
110 120 110
433,5
198 134
159 min.
110 120 110
466
327 600
238
54
400
299
frontal view
side view
frontal view
640
side view
Technical drawings - graphs - flue systems
Flexible ducting systems gas condensing boilers KHG714093510
.
KHG714093510
.
KHG714093610
.
KHG714093610
.
. KHG714105710 . (1,5 m) KHG714111210
.
KHG714105710 (1,5 m)
.
.
KHG714105810 (20 m)
.
KHG714106210
KHG714105810 (20 m)
KHG714106210
. KHG714059910 . KHG714105910 .
.
. KHG714059910 .
KHG714059211
KHG714059211
drain condensate
KHG714106010
.
KHG714059113
.
KHG714059113
.
Chimney terminal for a gas condensing boilers
130
50
Ø 126 Ø 81,5
Ø 60 1150
Ø 100
.
484
25
KHG 714093910 Reduction kit from Ø 80/125 to Ø 60/100
5
50
200
138
Ø 126
Ø 80 Ø 125
.
KHG 714093510 Coaxial vertical chimney terminal Ø 80/125
Ø 80
.
KHG 714093810 Dual flue tubes adapter for coaxial chimney from Ø 80/80 to Ø 80/125
55
Dual flue system Luna3 Comfort - Luna3 - Luna3 Comfort + Combi - Luna3 Comfort Air - Luna3 Blue - Luna3 Comfort Max Luna3 Silver Space - Ecofour - Fourtech - Mainfour L2
L1
960
L
300
Luna3 Comfort Luna3 Ecofour Blue Fourtech Mainfour 25 kW 31 kW 40
25
20
30
30 (G20) - 25 (G31)
25
L2 MAX m
10
10
10
10
10
10
-
-
-
-
25
22
25 kW
31 kW
10
8
L MAX m
Luna3 Blue
Ecofour Fourtech Mainfour
10
10
1150 500
500 1150
(L1+L2) MAX m
*B22
Luna3 Comfort
Luna3 Silver Space* 25 kW 31 kW
L
L
Luna3 Comfort
L MAX m
25 kW
31 kW
15
12
Luna3 Blue
Ecofour Fourtech
Mainfour
10
15
12
Luna3 Comfort 25 kW
31 kW
14
10
L MAX m
Luna3 Blue
Ecofour Fourtech
Mainfour
9
14
11
If the pipe length is longer than 6 meters the condensation storage kit must be installed. Tube maximum length (m)
Length reduction for a 90° bend insertion (m)
Installation with terminal Ø 80
80
0,5
0,25
Installation with chimney terminal
15
0,5
0,25
188
120
450
450
frontal view
frontal view
94
345
side view
Ecofour - Fourtech - Mainfour 97
= 400
frontal view
130
=
398
120 450
frontal view
frontal view
122
94
Front view
= 400
94
550
side view
Luna3 Silver Space
97
frontal view
94
450
120
120
=
56
97
145
130
145
97
94
120
299
side view
143 min
143 min
120
94
226
94
120 324
frontal view
94
120 226
94
324
frontal view
143 min
94
143 min
94
143 min
94
Luna3 Comfort + Combi
143 min
Luna3 Comfort - Luna3 - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max
Length reduction for a 45° bend insertion (m)
250
side view
Technical drawings - graphs - flue systems
Nuvola3 Comfort - Nuvola3 BS L2 650 1150
960
L
L
L
300
650 1150
L1
(l1 + L2) max= 30 m (25 m - 320Fi)
L max= 15 m - 10 m (mod. Comfort)
L max= 15 m
L max= 15 m
153 120
94 94
135 min.
Length reduction for a 90° Length reduction for a 45° bend insertion (m) bend insertion (m)
frontal view
Ø Flue (mm)
Installation with proof terminal
0,5
0,25
80
Installation with chimney terminal
0,5
0,25
133
side view
960 300
L1
500
L2
500 1150
L2
L max=5,5 m
L1
1150
Slim
L max=4,5 m
FLUE PIPE (L1) MAXIMUM LENGTH WITH A 90° BEND: 10 m. INTAKE PIPE (L2) MAXIMUM LENGTH WITH A 90° BEND: 10 m. Length reduction for a 45° bend insertion (m)
Ø Flue (mm)
20
0,5
0,25
80
6
0,5
0,25
Slim 1.230 Fi/FiN, 1.300 Fi/FiN 97
133
Slim 2.300 Fi
97
97
101,5 min
Installation with chimney terminal
Length reduction for a 90° bend insertion (m)
101,5 min
Installation with proof terminal
Tubes maximum length (m)
119 115
97
119 416
234
235
above view
above view
525
998
467
Chimney terminal for gas boilers
Ø 100
.
.
KHG 714010610 Dual flue horizontal chimney terminal Ø 80/125
Ø 60
KHG 714036410 Vertical chimney terminal for coaxial flue system Ø 60/100
KHG 714036510 Dual flue vertical chimney terminal Ø 80/125
.
57
Collectors for forced natural draft installation SB 25 + V SB 25 + O
SB 20 + V SB 20 + O
0,9 0,8 0,7 0,6
SB25+O
SB25+V
0,5 0,4 0,3 0,2 0,1 0
I
(*)
I
(*)
0,9 0,8 0,7 0,6
SB 25 + V 2187 1147 SB 25 + O 1147 2187 SB 20 + V 1755 1148 SB 20 + O 1148 1755 SB 21 +
SB20+V
0,5
h x w x d (mm)
0,4
87 87 87 87
SB20+O
0,3 0,2 0,1 0
SB 100
SB 100
SB 100
h x w x d (mm) 2064
4896
114
SVB 26
I
(*)
I
(*)
SVB 26
SVB 26
h x w x d (mm) 1560
1647
107
SB 21+
SB 21+
0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2
SB 21+
0,1
h x w x d (mm) 1753
1147
0
87
0.0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
I
58
(*) I = total incidental radiation on the collector surface (W/m2) tm = average temperature of the absorbing surface (째C) ta = room temperature (째C)
(*)
Technical drawings - graphs - flue systems
Indirect cylinders LUNA UB INOX LUNA UB 80, 120
SLIM UB INOX SLIM UB 80, 120
A B
Connection heating system flow/indirect cylinder 3/4”M Connection indirect cylinder return/heating system 3/4” M
G
C D E F
Mains water 1/2” M Domestic hot water outlet 1/2” M Relief valve 1/2” F Recirculation 1/2” M
H
G
G = 45 mm (80 l) 120 mm (120 l) H = 450 mm (80 l) 600 mm (120 l)
LUNA3 COMFORT + COMBI
+
=
Dimensions (mm) Combi
hxwxd 879x450x550
Luna3 Comfort + Combi
1642x450x550
1.240 Fi - 1.310 Fi - 1.240 i models
Dimensions (hxØ) - weight
UB 200 DC
1275x600 mm - 107 kg
UB 200 SC
1275x600 mm - 95 kg
UB 200 SC/DC
Dimensions (hxØ) - weight
UB 300 DC+
UB 300 SC+/DC+
1797x600 mm - 135 kg
UB 300 SC+
1797x600 mm - 118 kg
UB 400 DC+
1780x700 mm - 161 kg
UB 400 SC+
1780x700 mm - 144 kg
UB 400 SC+/DC+
59
Indirect cylinders Dimensions (hxØ) - weight
UBSS 250 DC
1743x545 mm - 58 kg
UBSS 260 SC
1804x545 mm - 48 kg
UBSS SC/DC
Dimensions (hxwxd) - weight
UB 200 SOLAR
1500x600x640 mm - 145 kg
UB 200 SOLAR
Dimensions (hxØ) - weight
UBSI 300
1706x610 mm - 135 kg
UBSI 300
Dimensions (hxØ) - weight
UB 500 DC
UB 1500 DC
UB 800 DC
UB 2000 SC/DC
UB 1000 SC/DC
UB 500 DC
1780x760 mm -174 kg
UB 800 DC
1905x990 mm - 235 kg
UB 1000 SC
2120x940 mm - 206 kg
UB 1000 DC
2155x990 mm - 243 kg
UB 1500 DC
2285x1200 mm - 386 kg
UB 2000 SC
2550x1300 mm - 465 kg
UB 2000 DC
2550x1300 mm - 465 kg
UB 3000 SC
2980x1400 mm - 670 kg
UB 3000 SC
Dimensions (hxØ) - weight
UBTT 1000
60
UBPT 1000
UBPT 2000
UBPU 1500 SC
UBTT 1000
2090x990 mm - 245 kg
UBPT 1000
2110x1030 mm - 210 kg
UBPT 2000
2380x1340 mm - 325 kg
UBPU 1500 SC
2150x1300 mm - 230 kg
Technical drawings - graphs - flue systems
Electric water heaters STORAGE upright 30 lt
upright 50/80/100 lt
50 lt upright 80 lt upright 100 lt upright 80 lt horizontal 100 lt horizontal
H
H1
520 760 920 760 920
360 565 760 395 555
dimensions (mm)
horizontal 80/100 lt
10-15 lt, above and under sink
10 lt
15 lt
A
267
350
B
250
310
C
70
100
D
128
168
dimensions (mm)
61
Electric water heaters Storage thermoelectric upright 50/80/100 lt
horizontal 80/100 lt
272
=
520 760 920 760 920
360 565 760 395 555
165 250 250 250 250
100
35
=
G 1/2
H1
=
15
175
G 1/2 15 105
100
O 440
35
H2
H =
O 440
235
50 lt upright TD/TS 80 lt upright TD/TS 100 lt upright TD/TS 80 lt horizontal TD/TS 100 lt horizontal TD/TS
H1
dimensions (mm)
G 3/4
H2
H1
H
250
355
G 3/4
H
Gas water heaters SAG2 50 - 80 - 100
MODEL SAG2 50
SAG2 300 T
A
B
460
613
C 313
SAG2 80
710
863
518
SAG2 100
830
983
638
SAG2 125 T - 155 T - 195 T
MODEL
A (±3)
B (±3)
SAG2 125 T
1150
1250
SAG2 155 T
1320
1420
SAG2 195 T
1590
1730
62
MODEL
SAG2 300 T
A
1700
B
1500
C
700
D
600
E
375
F
845
G
1235
I
140
M
620
N
100
P
1” 1/4
Q
INLET COLD WATER 1 - SHUT OFF VALVE 2 - PRESSURE REDUCER 3 - SAFETY VALVE 4 - EXPANSION VESSEL
R
HOT WATER OUTLET
S
DRAIN CONNECTION – ½” 5 - DRAIN VALVE
T
RECIRCULATION FITTING
Accessories for gas condensing and gas boilers Flue Systems - Coaxial flue 64
- Dual flue - Flexible ducting system - Special accessories
66 68 68
Other accessories - Replacement kit 69
- Installation templates - Solar integration
69 69
Hydraulic accessories 70 Outdoor installation accessories 73
Thermoregulation accessories
73
Mixing systems accessories 76 Other accessories 77
63
Flue pipe accessories Coaxial flue system for gas condensing boilers Description
*+KHG 714093910 •
64
Code
PP coaxial flue pipes with terminal Ø 60/100 L=750 mm supplied with windproof terminal and sealing collar
KHG 714059613 •
PP coaxial flue pipe extension Ø 60/100 L=1000 mm
KHG 714059516 •
Coaxial flue pipe extension L=500 - Ø 60/100
KHG 714119810 •
PP coaxial flue pipe extension with checking profile - Ø 60/100
KHG 714119510 •
PP coaxial 90° bend Ø 60/100
KHG 714059717 •
Coaxial 90° bend with checking profile - Ø 60/100
KHG 714119310 •
PP coaxial 45° bend Ø 60/100
KHG 714059817 •
PP coaxial flue pipes with terminal Ø 80/125 L=1000 mm supplied with windproof terminal and sealing collar
KHG 714088910 •
PP coaxial flue pipe extension Ø 80/125 L=1000 mm
KHG 714088511 •
PP coaxial flue pipe extension Ø 80/125 L=500 mm
KHG 714088610 •
PP coaxial 90° bend Ø 80/125
KHG 714088711 •
PP coaxial 45° bend Ø 80/125
KHG 714088811 •
Internal sealing collar Ø 100
KHG 714017710 •
PP vertical chimney terminal Ø 80/125*
KHG 714093510 •
PP reduction from Ø 80/125 to Ø 60/100
KHG 714093910 •
Flat roof tile to be used with a vertical chimney terminal Ø 80/125
KHG 714093610 •
Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°
KHG 714093710 •
Flue pipe accessories Coaxial flue system for gas boilers Description
Code
Coaxial flue tube with terminal Ø 60/100
KHG 714101810 •
Coaxial flue tube extension Ø 60/100 L=1000 mm
KHG 714101710 •
Coaxial flue tube extension Ø 60/100 L=500 mm
KHG 714103910 •
Coaxial flue tube extension Ø 60/100 with checking profile
KHG 714104010 •
Starting coaxial 90° bend Ø 60/100
KHG 714101410 •
Coaxial 90° bend Ø 60/100
KHG 714104110 •
Coaxial 90° bend Ø 60/100 with checking profile
KHG 714101510 •
Coaxial 45° bend Ø 60/100
KHG 714101610 •
Reduction from Ø 80/125 to Ø 60/100
KHG 714119410 •
Coaxial flue tube with terminal Ø 80/125
KHG 714140610 •
Coaxial flue tube extension Ø 80/125 L=1000 mm
KHG 714140410 •
Coaxial 90° bend Ø 80/125 with checking profile
KHG 714140510 •
Telescopic coaxial flue pipe Ø 60/100
710806301 •
Coaxial reduction kit Ø 80/125 - Ø 60/100 with draining trap
KHG 714102010 •
Coaxial condensate collector kit Ø 60/100 (it replaces KHG 714087710)
KHG 714119710 •
Internal sealing collar Ø 100
KHG 714017710 •
Adapter for 45° bend/vertical chimney
KHG 714101910 •
Vertical chimney terminal for coaxial flue system
KHG 714036410 •
Flat roof tile
KHG 714036710 •
Pitched roof tile
KHG 714036610 • 65
Flue pipe accessories Dual flue system for gas condensing boilers
* In PP ** +KHG 714093810 • 66
Description
Code
Adjustable dual flue system Ø 80
710268902 •
Dual flue system Ø 80 it includes: flue reduction, intake connection
KHG 714059113 •
Vertical flue system B23 type installation*
KHG 714111011 •
Tube extension Ø 80 L=1000 mm*
KHG 714059411 •
Tube extension Ø 80 L=500 mm*
KHG 714059910 •
90° bend Ø 80*
KHG 714059211 •
45° bend Ø 80*
KHG 714059311 •
Dual flue terminal Ø 80
KHG 714010410 •
Reduction M/F from Ø 80 to Ø 60*
KHG 714075610 •
Tube extension Ø 60 L=1000 mm*
KHG 714075310 •
Tube extension Ø 60 L=500 mm*
KHG 714075210 •
90° bend Ø 60*
KHG 714075410 •
45° bend Ø 60*
KHG 714075510 •
Dual flue terminal Ø 60
KHG 714037210 •
Reduction M/F from Ø 80 to Ø 50*
710717501 •
Tube extension Ø 50 L=500 mm *
710717401 •
Tube extension Ø 50 L=1000 mm *
710705701 •
Tube extension Ø 50 L=2000 mm *
710705801 •
90° bend Ø 50*
710706001 •
45° bend Ø 50*
710705901 •
90° flue terminal Ø 50
710717601 •
Tube Ø 80 centring (pack of 5)
KHG 714037411 •
Clamp centring kit Ø 80
KHG 714106110 •
Tube Ø 60 centring kit (pack of 5)
KHG 714051510 •
Tube Ø 80 supporting bracket (pack of 5)
KHG 714037310 •
Internal sealing collar Ø 80
KHG 714018510 •
External sealing collar Ø 80
KHG 714018411 •
Coaxial vertical chimney terminal 80/125**
KHG 714093510 •
Dual flue pipes adapter for coaxial chimney from Ø 80/80 to Ø 80/125
KHG 714093810 •
Flat roof tile Ø 125 to be used with a vertical chimney terminal
KHG 714093610 •
Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°
KHG 714093710 •
Flue pipe accessories Dual flue system for fanned flue gas boilers Description
Code
Dual flue AFR system kit
KHG 714061512 •
Painted tube Ø 80 L=1000 mm
KHG 714018310 •
Painted tube Ø 80 L=500 mm
KHG 714018210 •
Aluminium tube Ø 80 L=2000 mm
KHG 714038710 •
Aluminium tube Ø 80 L=1000 mm
KHG 714038610 •
Aluminium tube Ø 80 L=500 mm
KHG 714038510 •
90° bend Ø 80
KHG 714018010 •
45° bend Ø 80
KHG 714018110 •
Painted insulated tube Ø 80 L=1000 mm
KHG 714105410 •
Painted insulated tube Ø 80 L=500 mm
KHG 714105310 •
Insulated bend 90° Ø 80
KHG 714105110 •
Insulated bend 45° Ø 80
KHG 714105210 •
Insulated tube adapter
KHG 714030510 •
Adjustable dual flue system Ø 80
KHG 714136210 •
Condensate collector kit (phasing out)
KHG 714054710 •
Condensate collector kit - Ø 80 (it replaces KHG714054710)
KHG 714119610 •
Vertical condensate collector kit Ø 80
KHG 714122810 •
Air inlet/outlet flue socket kit
KHG 714050411 •
Air outlet flue socket kit
KHG 714050311 •
Tube Ø 80 centring kit (pack of 5)
KHG 714037411 •
Clamp centring kit
KHG 714106110 •
Tube Ø 80 supporting bracket (pack of 5)
KHG 714037310 •
Internal sealing collar Ø 80
KHG 714018510 •
Internal sealing collar for insulated tubes Ø 100
KHG 714017710 •
67
Flue pipe accessories Dual flue system for fanned flue gas boilers Description
Code
External sealing collar Ø 80
KHG 714018411 •
Dual flue vertical chimney terminal Ø 80/125
KHG 714036510 •
Flat roof tile
KHG 714036710 •
Pitched roof tile
KHG 714036610 •
Dual flue horizontal chimney terminal
KHG 714010610 •
Dual flue terminal Ø 80
KHG 714010410 •
Dual flue system for fanned flue gas boilers: Luna3 Blue Description
Code
Dual flue system kit
KHG 714017912 •
Painted tube Ø 80 L=1000 mm
KHG 714018310 •
Painted tube Ø 80 L=500 mm
KHG 714018210 •
Bend 90° Ø 80
KHG 714018010 •
Dual flue terminal Ø 80
KHG 714010410 •
Flexible ducting system for condensing boilers Description
Code
PP flexible tube Ø 80 L= 1,5 m
KHG 714105710 •
PP flexible tube Ø 80 L= 20 m
KHG 714105810 •
PP 90° bend Ø 80 with supporting bracket and condensate drainings
KHG 714105910 •
PP 90° bend Ø 80 with supporting bracket
KHG 714106010 •
Flexible centring kit Ø 80 (pack of 3)
KHG 714106210 •
Triple lips gaskets kit Ø 80 (pack of 5)
KHG 714111210 •
Special accessories in case of hard weather conditions Description
68
Code
Horizontal coaxial flue terminal Ø 60/100
KHG 714136110 •
Vertical coaxial flue terminal Ø 60/100 for gas boilers
KUG 714135710 •
Vertical coaxial flue terminal Ø 60/100 for condensing boiler
KUG 714135810 •
Vertical coaxial flue terminal Ø 80/125 for condensing boiler
KUG 714135910 •
Other accessories: replacement kits Description
Universal replacement kit: it includes fittings and flexible stainless steel pipes
Code
KHG 714058811 •
Platinum Duo-tec (1)
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Luna3 Comfort HT Solar
Code
Ecofour Fourtech Mainfour
•
•
Luna Platinum, Duo-tec, Compact, Max
Installation templates Description
Luna3
Nuvola3 BS Nuvola3 Comfort
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Platinum Duo-tec (1)
Luna3 Comfort HT Solar
Luna3 Comfort HT Solar template
KSL 714122011 •
Metal template for Luna3 Comfort fanned flue models s •
KHG 714062010 •
•
Metal template boilers for outdoor models
KHG 714076411 •
Silver Space
Metal template for storage boilers
KHG 714060111 •
Metal template for combi
KSL 714086411 •
Ecofour Fourtech Mainfour
Slim Slim HP
Luna3
Nuvola3 BS Nuvola3 Comfort
•
• Comfort Combi
• For open flue and fanned flue Luna3 models. s
Not available for Luna3 Silver Space.
Accessories for solar integration Description
Code
KHG 714123111 •
Platinum Duo-tec (1)
Luna Platinum, Duo-tec, Compact, Max
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Luna3 Comfort HT Solar
Luna3
Ecofour Fourtech Mainfour
•
•
Nuvola3 BS Nuvola3 Comfort
Solar valve kit
69
Hydraulic accessories Description
Code
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Platinum Duo-tec (1)
710438401 •
Luna Platinum
710351201 •
Duo-tec, Max
710351102 •
Duo-tec, Max
710351001 •
Duo-tec
710698001 •
Duo-tec Compact
Heating systems taps and connection pipes
Heating systems taps and connection pipes
Luna3 Comfort HT Solar
Luna3
Slim Slim HP
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
Connection pipes for combi boiler
Connection pipes for heating only boilers
Telescopic connection pipes with heating and mains water valves
KHG 714110710 •
•
KHG 714107010 •
•
KHG 714110810 •
•
Hydraulic connection kit for combi boiler
Hydraulic connection kit for heating only boiler
Hydraulic connection kit with heating valves
•
KHG 714028910 • Telescopic connection pipes with gas inlet valve
710738801 •
Nuvola3 BS
Telescopic connection pipes
Comfort Combi
KSL 714087111 • Combi universal kit
KHG 714023310 • Vertical tube connection kit: it includes 5 tubes for vertical connection
Luna Platinum, Duo-tec, Compact, Max
KHG 714052610 •* Mains water valve without filter *
* To be used for Slim of connected with female/female adapter available on the market.
70
•
+ KHG 714028910 •
Slim (combi boilers)
•
Hydraulic accessories Description
Code
KHG 714022011 •*
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Platinum Duo-tec (1)
•
Luna3 Comfort HT Solar
Luna3 HT
Luna3
Slim Slim HP
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
•
Slim (combi boilers) + 1.230 - 1.300 Fi / FiN models
•
•
Heating system flow/return valve without filter *
•
KHG 714052510 •
Gas valve kit
710497601 •
Luna Platinum, Duo-tec, Max
Stop valve kit to avoid installation water to get in contact with waterworks
•
KHG 714023211 • Stop valve kit to avoid installation water to get in contact with waterworkss
Nuvola3 Comfort
KHG 714083810 • Stop valve kit for storage boilers to avoid installation water to get in contact with waterworks
KHG 714083910 • Stop valve kit for condensing storage boilers to avoid installation water to get in contact with waterworks
Nuvola Platinum, Nuvola Duo-tec
KHG 714021611 •
•
Expansion vessel (10 lt) n
* To be used for Slim of connected with female/female adapter available on the market. s Not available for Luna3 Silver Space n Not available for Luna3 Silver Space/Luna3 Comfort Max
71
Hydraulic accessories Description
Code
KHG 714079711 •
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Platinum Duo-tec (1)
Luna3 Comfort HT Solar
Luna3
Slim Slim HP
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
Nuvola Duo-tec
Additional expansion vessel (2 lt)
KHG 714034413 •
Nuvola3 BS
Additional expansion vessel (2 lt)
KSL 714086111 •
Comfort Combi
KHG 714085210 •
•
KHG 714022910 •
•
Combi additional expansion vessel (4 lt)
Pump UPS 15/70 AO GRUNDFOS
Flow restrictor 8 l/minss
KHG 714022710 •
Nuvola Platinum, Nuvola Duo-tec
Nuvola3 Comfort
Recirculating kit
KHG 714106610 •
Heating only
KFG 714111910 •
Heating only
3 way valve motor
3 way valve motor and hot water temperature sensor*
Heating only
KHG 714096311 • Electric 3 way kit for external connection
KHW 714087410 • DHW sensor – pump connecting cable
not available for: Luna3 Silver Space * to be used in case of heating only boilers Luna3 models for connection to any solar cylinders
s
72
Slim
Outdoor installation accessories Description
Code
Platinum Duo-tec (1)
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Luna3 Comfort HT Solar
Luna3
KHG 714024811 •
24 kW
KHG 714073410 •
•
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
Upper cover for open flue models
Upper cover for fanned flue models
Thermoregulation accessories Luna Platinum, Nuvola Platinum
(the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description
Code
Outdoor sensor for Platinum/Duo-tec
710487301 •
Wireless outdoor sensor THINK* (ONLY FOR PLATINUM BOILERS)
710302701 •
3LEDs interface THINK with support (ONLY FOR PLATINUM BOILERS)
710234002 •
5LEDs interface THINK with support (ONLY FOR PLATINUM BOILERS)
710244102 •
Wireless aerial-5 LEDs (ONLY FOR PLATINUM BOILERS)
710234301 •
Remote control THINK
710244202 •
Modulating room thermostat THINK (ONLY FOR PLATINUM BOILERS)
710106105 •
Wireless modulating room thermostat THINK* (ONLY FOR PLATINUM BOILERS)
710304401 •
Room thermostat with timer THINK (ONLY FOR PLATINUM BOILERS)
710298005 •
Wireless room thermostat with timer THINK* (ONLY FOR PLATINUM BOILERS)
710297904 •
Room thermostat
KHG 714062810 •
* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 .) when the remote control is installed on the wall, or with the wireless aerial (710234301 .) when the remote control is installed in the boiler control panel
73
Thermoregulation accessories Luna Platinum, Nuvola Platinum
(the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description
Code
Programmable clip-in module THINK (ONLY FOR PLATINUM BOILERS)
710034502 •
Heating flow/return sensor clip-in module THINK (ONLY FOR PLATINUM BOILERS)
KHG 714078910 •
Programmable external module THINK (ONLY FOR PLATINUM BOILERS)
710503704 •
Hot water temperature sensor
KHG 714076810 •
Thermoregulation accessories Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec (the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description
74
Code
Outdoor sensor for Platinum/Duo-tec
710487301 •
Modulating thermostat (ONLY FOR DUO-TEC BOILERS)
710434701 •
Wireless modulating thermostat – it includes wireless transmitter (ONLY FOR DUO-TEC boilers)
710543001 •
Modulating room thermostat with timer (ONLY FOR DUO-TEC BOILERS)
710433601 •
Wireless modulating thermostat with timer (ONLY FOR DUO-TEC BOILERS)
710543201 •
Room thermostat
KHG 714062810 •
Hot water temperature sensor
KHG 714076810 •
Thermoregulation accessories Description
Luna3 Comfort HT Solar
Code
KHG 714062112 •
Luna3
Slim Slim HP
•
Slim
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
•
Outdoor sensor
KHG 714072811
•
•
Outdoor sensor
KHG 714061610 •
Slim
KHG 714061710 •
Slim
Mechanical daily timer kit
Digital weekly timer
KHG 714106411 •
Luna3
Nuvola3 BS
KHG 714114710 •
Luna3
•
Remote controller and climatic regulator
Remote controller and climatic regulator wireless (already included in Luna3 Comfort Air)
KHG 714072612 •
Slim
KHG 714072511 •
Slim
Remote controller and climatic regulator
PCB interface for remote controller
KHG 714086810 •
•
•
Slim
•
•
KHG 714086711 •
•
•
Slim
•
•
KHG 714086910 •
•
•
Slim
•
•
Weekly timer and room thermostat nice time
Weekly timer and room thermostat magic time plus
Room thermostat
Fourtech Mainfour
KHG 714100510 • PCB for remote alarm signal
KHG 714106511 •
•
KHG 714061911 •
heating only
•
PCB interface for zone control
Hot water temperature sensor
LSB 710000090 •
Slim HP
LXO 000655644 •
Slim HP
Electric interface kit
Cascade controller kit
75
Mixing systems accessories
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
(Dimensions mm hxwxd: 600x450x160; MS models- hwxd: 700x450x160) Code
Platinum Duo-tec (1)
Luna3 Comfort HT Solar
Luna3
Slim Slim HP
Ecofour Fourtech Mainfour
Nuvola3 BS Nuvola3 Comfort
Box for universal mixing system kit “MS IN”
KHG 714128110 •
•
•
•
Luna
•
•
Mixing system kit “MS IN” THINK (1 HT zone- 2 LT zones)
7104769
Platinum
Mixing system kit “MS IN” THINK (1 HT zone- 1 LT zone)
7104770
Platinum
3 zones
7104823
2 zones
7104824
1 zone
7104825
• • •
• • •
• • •
• • •
• • •
• • •
Universal mixing system kit “MS IN” (1 HT zone – 1 LT zone)
KHG 71412911
•
•
•
•
•
•
Universal mixing system kit “MS IN” (1 HT zone – 2 LT zones)
KHG 71412801
•
•
•
•
•
•
Mixing system kit “MS IN” ( 2 LT zones)
KHG 71412921
•
•
•
•
•
•
Mixing system kit (*)
KFG 71407961
•
•
•
•
•
•
Additional pump to control a 3rd zone (*)
KHG 714085110 •
Kit for mixing system
Kit for mixing system
Kit for mixing system
Kit for mixing system
Kit for mixing system
Kit for mixing system
Description
Universal mixing system kit “MS IN” :
76
Other accessories Description
n
(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec
Code
Platinum Duo-tec (1)
Luna3 Comfort HT Solar
Luna3
Slim Slim HP
Ecofour Fourtech Mainfour
Installation kit separate installation Luna3 Comfort HT Solar and storage tank
KSL 714124110 •
Bottom cover
KHG 714073810 •
Polyphosphate batcher n
KHG 714023011 •
Luna Platinum
•
•
•
Polyphosphate recharge (pack of 4)
KHG 714024310 •
Luna Platinum
•
•
•
Condensate neutralizer kit (for boilers up to 100 kW)
KHG 714125610 •
•
•
Condensate neutralizer kit recharge (for boilers up to 100 kW)
KHG 714135310 •
•
•
Nuvola3 BS Nuvola3 Comfort
Luna3 HT Solar
•
not available for Luna3 Silver Space/Luna3 Comfort Max
Accessories for electric water heaters Description
Code
KHI 714053511 • 4 lt expansion vessel kit for 50-100 lt electric water heaters
KHI 714063310 • Universal bracket kit for horizontal water heaters
77
Accessories for UB Inox Description
Code
UB inox
Slim UB inox
KHG 714085410 •
•
•
KHG 714084810 •
•
KHG 714106610 •
•
KFG 714111910 •
•
KHG 714096311 •
•
UB Inox additional expansion vessel
Connection kit to indirect cylinder
3 way valve motor
3 way valve motor and hot water temperature sensor*
Electric 3 way kit for external connection
KHW 714085610 •
•
KHW 714096810 •
•
Connection pump kit
Connection kit to indirect cylinder for boilers > 35 kW
KSG 714088210 • Metal template UB Inox 80-120
78
•
•
Products technical data
Condensing gas boilers Gas boilers
80 81
79
80 92/42/EEC
4,1
4,1
2,1
2,1
24,7
20,5
NUVOLA DUO-TEC 24 (DHW)
NA3 COMFORT HT 240 SOLAR (heat.)
LUNA3 COMFORT HT 240 SOLAR (DHW) 24,7
LUNA3 COMFORT HT 120 SOLAR (heat.) 12,4
LUNA3 COMFORT HT 120 SOLAR (DHW) 12,4
3,5
3,5
2,3
2,3
3,5
3,5
3,5
4,8
4,8
3,5
20,6
28,9
DUO-TEC MAX 33 (heat.)
16,5
24,7
DUO-TEC MAX 24 (DHW)
3,5
5,9
NUVOLA DUO-TEC 24 (heat.)
20,6
DUO-TEC MAX 24 (heat.)
NUVOLA DUO-TEC 16 (DHW)
41,2
LUNA DUO-TEC 40 (DHW)
5,9
4,8
12,4
33
LUNA DUO-TEC 40 (heat.)
NUVOLA DUO-TEC 16 (heat.)
34
LUNA DUO-TEC 33 (DHW)
4,8
3,9
24,7
28,9
LUNA DUO-TEC 33 (heat.)
20,6
28,9
LUNA DUO-TEC 28 (DHW)
3,9
DUO-TEC COMPACT 24 (DHW)
24,7
LUNA DUO-TEC 28 (heat.)
3,5
DUO-TEC COMPACT 24 (heat.)
24,7
LUNA DUO-TEC 24 (DHW)
3,5
34
20,6
LUNA DUO-TEC 24 (heat.)
4,1
24,7
28,9
LUNA DUO-TEC 1.28
3,5
DUO-TEC COMPACT 1.24
24,7
LUNA DUO-TEC 1.24
2,1
3,4
2,9
2,5
2,1
3,4
2,9
2,5
2,1
3,3
2,5
2,1
2,1
DUO-TEC MAX 33 (DHW)
34
12,4
28,9
NUVOLA PLATINUM 33 (heat.)
LUNA DUO-TEC 1.12
24,7
NUVOLA PLATINUM 24 (DHW)
NUVOLA PLATINUM 33 (DHW)
34
20,6
28,9
LUNA PLATINUM 33 (heat.)
NUVOLA PLATINUM 24 (heat.)
24,7
LUNA PLATINUM 24 (DHW)
LUNA PLATINUM 33 (DHW)
33
20,6
24,7
LUNA PLATINUM 1.24
LUNA PLATINUM 24 (heat.)
17,4
LUNA PLATINUM 1.18
LUNA PLATINUM 1.32
12,4
LUNA PLATINUM 1.12
12
12
12
24
20
24
20
16
12
24
20
24
33
28
24
20
40
32
33
28
28
24
24
20
28
24
12
33
28
24
20
33
28
24
20
32
24
16,9
2
2
4
4
3,4
3,4
2,2
2,2
3,4
3,4
3,4
4,7
4,7
3,4
3,4
5,7
5,7
4,7
4,7
3,8
3,8
3,4
3,4
4
3,4
2
3,3
2,8
2,4
2
3,3
2,8
2,4
2
3,2
2,4
2
2
97,6
97,6
-
97,6
-
97,7
-
97,8
-
97,7
97,6
-
97,7
-
97,7
-
97,6
-
97,7
-
97,6
-
97,7
97,6
97,6
97,8
-
97,7
-
97,6
-
97,6
-
97,7
97,6
97,6
97,6
97,7
107,5
107,5
-
107,5
-
107,6
-
107,8
-
107,6
107,6
-
107,7
-
107,6
-
107,6
-
107,7
-
107,6
-
107,6
107,6
107,6
107,8
-
107,7
-
107,6
-
107,7
-
107,6
107,6
107,6
108
108
HHHH
HHHH
-
HHHH
-
HHHH
-
HHHH
-
HHHH
HHHH
-
HHHH
-
HHHH
-
HHHH
-
HHHH
-
HHHH
-
HHHH
HHHH
HHHH
HHHH
-
HHHH
-
HHHH
-
HHHH
-
HHHH
HHHH
HHHH
HHHH
HHHH
98,1
98,1
98,1
98,1
98,2
98,2
98,3
98,3
98,2
98,2
98,1
98,2
98,2
98,2
98,2
98,1
98,1
98,2
98,2
98,1
98,1
98,2
98,2
98,1
98,1
98,3
98,2
98,2
98,1
98,1
98,1
98,1
98,2
98,2
98,1
98,1
98,1
98,2
1,9
1,9
1,9
1,9
1,8
1,8
1,7
1,7
1,8
1,8
1,9
1,8
1,8
1,8
1,8
1,9
1,9
1,8
1,8
1,9
1,9
1,8
1,8
1,9
1,9
1,7
1,8
1,8
1,9
1,9
1,9
1,9
1,8
1,8
1,9
1,9
1,9
1,8
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
73
73
73
70
80
80
75
75
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
75
80
80
80
80
80
80
80
80
80
80
75
75
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
30
30
30
30
30
30
30
30
30
30
30
30
0,006
0,006
0,012
0,010
0,012
0,010
0,008
0,006
0,012
0,010
0,012
0,016
0,014
0,012
0,010
0,019
0,016
0,016
0,014
0,014
0,012
0,012
0,010
0,014
0,012
0,006
0,016
0,013
0,011
0,009
0,016
0,013
0,011
0,009
0,015
0,011
0,008
0,006
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
8,4
8,4
8,4
8,4
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
5,9
5,9
5,9
5,9
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
5,2
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
exceeding flue flue CO2 O2 air mass temp. and flow/rate max % kg/s 째C % %
39
39
39
39
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
30
30
30
30
30
30
30
30
30
30
30
30
0,001
0,001
0,002
0,002
0,002
0,002
0,001
0,001
0,002
0,002
0,002
0,002
0,002
0,002
0,002
0,003
0,003
0,002
0,002
0,002
0,002
0,002
0,002
0,002
0,002
0,001
0,002
0,001
0,001
0,001
0,002
0,001
0,001
0,001
0,002
0,001
0,001
0,001
297
180
297
180
102
102
112
112
104
104
102
133
133
102
102
142
142
133
133
114
114
102
102
114
102
108
145
145
130
130
145
145
120
120
130
120
110
95
90
90
90
90
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CL0214
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
0085CM0140
Nr.
Certificate EEC
0085BS0290
0085BS0290
0085BS0290
0085BS0290
0085CL0214LU-
exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W
Power consumption
burner
not working Maximum output Minimum Output
MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating chimney flue CO2 O2 temp. number efficiency heat heat heat temp. Pn 70째C 92/42/EEC losses losses losses max kW kW kW kW % % % % % % 째C % %
Efficiency (Hi) Maximum Output
Heat input Heat output
PRODUCT
Product technical data condensing gas boilers
92/42/EEC
24,5
24,5
SLIM 1.230 Fi
SLIM 1.230 FiN
33
26,3
NUVOLA3 COMFORT 240Fi
SLIM 2.300 Fi
17
30,1
NUVOLA3 COMFORT 280Fi
33
34,5
NUVOLA3 COMFORT 320Fi
33
26,3
NUVOLA3 240Fi BS
SLIM 1.300 Fi
30,1
NUVOLA3 280Fi BS
SLIM 1.300 FiN
13,5
15,1
ECOFOUR 1.14 F
17
17
13,5
11,9
11,9
11,9
11,9
11,9
7,4
10,6
10,6
25,8
7,4
25,8
15,1
FOURTECH 1.14 F
10,6
ECOFOUR 1.24 F
25,8
FOURTECH 1.24 F
10,6
10,6
11,9
11,9
11,9
11,9
10,6
11,9
10,6
11,9
10,6
11,9
11,9
10,6
10,6
11,9
11,9
11,9
10,6
10,6
ECOFOUR 24 F
25,8
25,8
MAINFOUR 240 F
FOURTECH 24 F
30,1
26,9
LUNA3 SILVER SPACE 250Fi
LUNA3 BLUE 280Fi
33,3
LUNA3 COMFORT MAX 310Fi
26,3
26,9
LUNA3 COMFORT MAX 250Fi
26,3
33,3
LUNA3 COMFORT 1.310Fi
LUNA3 BLUE 1.240Fi
33,3
LUNA3 COMFORT 310Fi
LUNA3 BLUE 240Fi
26,9
LUNA3 COMFORT 1.240Fi
33,3
26,9
LUNA3 COMFORT 240Fi
LUNA3 COMFORT AIR 310Fi
33,3
LUNA3 1.310Fi
33,3
33,3
LUNA3 310Fi
26,9
30,1
LUNA3 280Fi
LUNA3 COMFORT AIR 250Fi
26,9
LUNA3 1.240Fi
LUNA3 SILVER SPACE 310Fi
26,9
LUNA3 240Fi
29,7
29,7
29,7
22,1
22,1
24,4
28
32
24,4
28
14
24
24
14
24
24
24
28
24
24
31
25
31
25
31
25
31
31
25
25
31
31
28
25
25
14,9
14,9
14,9
11,8
11,8
10,4
10,4
10,4
10,4
10,4
6
9,3
9,3
6
9,3
9,3
9,3
10,7
10,7
10,7
10,4
9,3
10,4
9,3
10,4
9,3
10,4
10,4
9,3
9,3
10,4
10,4
10,4
9,3
9,3
90,3
90,3
90,3
90
90
92,9
93,1
93,2
92,9
93,1
92,5
92,9
92,9
92,5
92,9
92,9
92,9
93,1
93,2
93,2
93,1
92,9
93,1
92,9
93,1
92,9
93,1
93,1
92,9
92,9
93,1
93,1
93,1
92,9
92,9
88,8
88,8
88,8
89,6
89,6
90,4
90,5
90,5
90,4
90,5
89,8
90,2
90,4
89,8
90,2
90,4
90,2
92,5
91,2
91,2
90,8
90,2
90,8
90,2
90,8
90,2
90,8
90,8
90,2
90,2
90,8
90,8
90,8
90,2
90,2
HH
HH
HH
HH
HH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
HHH
92,7
92,7
92,7
92,3
92,3
93,5
94,0
94,1
93,5
94,0
92,9
93,3
93,3
92,9
93,3
93,3
93,3
93,6
93,6
93,6
93,8
93,4
93,8
93,4
93,8
93,4
93,8
93,8
93,4
93,4
93,8
93,8
93,8
93,4
93,4
7,3
7,3
7,3
7,7
7,7
6,5
6,0
5,9
6,5
6,0
7,1
6,7
6,7
7,1
6,7
6,7
6,7
6,4
6,4
6,4
6,2
6,6
6,2
6,6
6,2
6,6
6,2
6,2
6,6
6,6
6,2
6,2
6,2
6,6
6,6
2,4
2,4
2,4
2,3
2,3
0,6
0,9
0,9
0,6
0,9
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,5
0,4
0,4
0,7
0,5
0,7
0,5
0,7
0,5
0,7
0,7
0,5
0,5
0,7
0,7
0,7
0,5
0,5
-
-
-
-
-
0,6
0,7
0,7
0,6
0,7
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,5
0,4
0,4
0,5
0,4
0,5
0,4
0,5
0,4
0,5
0,5
0,4
0,4
0,5
0,5
0,5
0,4
0,4
159
159
159
152
152
134
142
142
134
142
115
146
146
115
146
146
149
140
135
135
145
135
145
135
145
135
145
145
135
135
145
145
140
135
135
8,3
8,3
8,3
6,6
6,6
6,1
7,1
6,7
6,1
7,1
4,9
7,2
7,2
4,9
7,2
7,2
6,4
7,1
5,6
5,6
7,4
6,4
7,4
6,4
7,4
6,4
7,4
7,4
6,4
6,4
7,4
7,4
6,8
6,4
6,4
6,1
6,1
6,1
9,2
9,2
10,1
8,3
9,0
10,1
8,3
12,2
8,1
8,1
12,2
8,1
8,1
9,5
8,3
10,9
10,9
7,7
9,5
7,7
9,5
7,7
9,5
7,7
7,7
9,5
9,5
7,7
7,7
8,8
9,5
9,5
41
41
41
77
77
92
65
75
92
65
139
63
63
139
63
63
83
65
109
109
58
83
58
83
58
83
58
58
83
83
58
58
72
83
83
0,016
0,016
0,016
0,015
0,015
0,018
0,018
0,022
0,018
0,018
0,012
0,014
0,014
0,012
0,014
0,014
0,016
0,017
0,018
0,018
0,018
0,017
0,018
0,017
0,018
0,017
0,018
0,018
0,017
0,017
0,018
0,018
0,018
0,017
0,017
114,6
114,6
114,6
114
114
108
108
108
108
108
100
116
116
100
116
116
119
108
106
106
110
100
110
100
110
100
110
110
100
100
110
110
110
100
100
3,5
3,5
3,5
3
3
2,5
2,4
2,1
2,5
2,4
2,2
2,7
2,7
2,2
2,7
2,7
2,4
3,2
3,0
3,0
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
14,7
14,7
14,7
15,6
15,6
16,5
16,7
17,2
16,5
16,7
17,1
16,2
16,2
17,1
16,2
16,2
16,7
15,3
15,6
15,6
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
16,9
exceeding flue flue CO2 O2 air mass temp. and flow/rate max % kg/s 째C % %
234
234
234
290
290
368
388
457
368
388
432
333
333
432
333
333
388
266
290
290
409
409
409
409
409
409
409
409
409
409
409
409
409
409
409
0,018
0,018
0,018
0,017
0,017
0,017
0,018
0,021
0,017
0,018
0,012
0,014
0,014
0,012
0,014
0,014
0,016
0,014
0,015
0,015
0,019
0,017
0,019
0,017
0,019
0,017
0,019
0,019
0,017
0,017
0,019
0,019
0,019
0,017
0,017
170
70
170
70
170
190
190
190
190
190
120
130
130
120
130
130
130
165
135
135
165
135
165
135
165
135
165
165
135
135
165
165
165
135
135
80
-
80
-
80
75
90
90
75
90
75
75
75
75
75
75
75
90
90
90
90
75
90
75
90
75
90
90
75
75
90
90
90
75
75
exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W
51BL1808
51BL1808
51BL1808
51BL1808
51BL1808
51BR3405
51BR3405
51BR3405
51BR3405
51BR3405
51BT3642
51BT3642
51BT3642
51BT3642
51BT3642
51BT3642
51BU3836
0085BM0323
0085BM0323
0085BM0323
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3238
51BR3279
51BR3238
51BR3238
Nr.
Certificate EEC
Power consumption
burner
not working Maximum output Minimum Output
MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating chimney flue CO2 O2 temp. number efficiency heat heat heat temp. Pn 70째C 92/42/EEC losses losses losses max kW kW kW kW % % % % % % 째C % %
Efficiency (Hi) Maximum Output
Heat input Heat output
PRODUCT
Product technical data gas boilers
81
82
Heat input
Heat output
Efficiency (hi)
Maximum output
Maximum output
Minimum output
Power consumption
26,3
26,3
26,3
19,4
19,4
26,3
26,3
26,3
15,4
26,3
26,3
15,4
31,1
27,1
31,1
27,1
LUNA3 COMFORT 240i
LUNA3 COMFORT 1.240i
LUNA3 BLUE 240i
LUNA3 BLUE 180i
LUNA3 BLUE 1.180i
MAINFOUR 24
FOURTECH 24
FOURTECH 1.24
FOURTECH 1.14
ECOFOUR 24
ECOFOUR 1.24
ECOFOUR 1.14
NUVOLA3 280i BS
NUVOLA3 240i BS
NUVOLA3 COMFORT 280i
NUVOLA3 COMFORT 240i
11,9
11,9
11,9
11,9
7,1
10,6
10,6
7,1
10,6
10,6
10,6
10,6
10,6
11,9
10,6
10,6
10,6
10,6
10,4
10,4
10,4
10,4
6
9,3
9,3
6
9,3
9,3
9,3
9,3
9,3
10,4
9,3
9,3
9,3
9,3
Heat output
24,4
28
24,4
28
14
24
24
14
24
24
24
17,5
17,5
24
24
24
24
24
90,2
90,6
90,2
90,6
90,9
91,2
91,2
90,9
91,2
91,2
90,6
90,3
90,3
90,3
91,2
91,2
91,2
91,2
Efficiency (hi)
89,4
89,5
89,4
89,5
88,6
89,3
89,3
88,6
89,3
89,3
89,3
89,6
89,6
89,6
90,29
90,29
90,29
90,29
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
8,3
7,5
8,3
7,5
8,3
7,8
7,8
8,3
7,8
7,8
8,4
8,8
8,8
8,6
7,7
7,7
7,7
7,7
Maximum output
91,7
92,5
91,7
92,5
91,7
92,2
92,2
91,7
92,2
92,2
91,6
91,2
91,2
91,4
92,3
92,3
92,3
92,3
1,5
1,9
1,5
1,9
0,8
1,0
1,0
0,8
1,0
1,0
1,0
0,9
0,9
1,1
1,1
1,1
1,1
1,1
110
115
110
115
99
110
110
99
110
110
120
100
100
120
110
110
110
110
4,9
5,2
4,9
5,2
4,1
5
5
4,1
5
5
4,7
5
5
4,9
5,3
5,3
5,3
5,3
Maximum output
12,2
11,7
12,2
11,7
13,6
12,0
12,0
13,6
12,0
12,0
12,6
12,0
12,0
12,2
11,5
11,5
11,5
11,5
139
125
139
125
185
134
134
185
134
134
149
134
134
139
121
121
121
121
0,022
0,024
0,022
0,024
0,014
0,020
0,020
0,014
0,020
0,020
0,021
0,015
0,015
0,021
0,019
0,019
0,019
0,019
82
82
82
82
83
85
85
83
85
85
86
86
86
86
85
85
85
85
17,2
17,2
17,2
17,2
17,4
17,2
17,2
17,4
17,2
17,2
17,2
15,3
15,3
16,5
16,9
16,9
16,9
16,9
Minimum output
2,1
2,1
2,1
2,1
2
2,1
2,1
2
2,1
2,1
2,1
3,2
3,2
2,5
2,3
2,3
2,3
2,3
457
457
457
457
485
457
457
485
457
457
457
266
266
368
409
409
409
409
0,021
0,021
0,021
0,021
0,013
0,018
0,018
0,013
0,018
0,018
0,018
0,012
0,012
0,017
0,017
0,017
0,017
0,017
75
90
75
90
75
75
75
75
75
75
75
90
90
90
75
75
75
75
51BR3407
51BR3407
51BR3407
51BR3407
51BT3644
51BT3644
51BT3644
51BT3644
51BT3644
51BT3644
51BU3834
0085BM0324
0085BM0324
0085BM0324
51BR3240
51BR3240
51BR3240
51BR3240
Power consumption
110
110
110
110
80
80
80
80
80
80
80
110
110
110
80
80
80
80
17
13,5
11,8
14,9
Heat output
29,7
22,1 90
90,2
Efficiency (hi)
88,5
88,5 HH
HH 8,3
7,1
Maximum output
91,7
92,9 1,7
2,7
96 110
4 4,4
Maximum output
13,1
13,8
166
193
0,029
0,023
96 94,5
3
16,2
15,6
Minimum output
2,7
333
290
0,023
0,017
80
80
51AQ388
51AQ388
Power consumption
120
120
16,5
24,5
33
24,5
33
44,4
54,1
69
SLIM 1.150 i
SLIM 1.230 i
SLIM 1.300 i
SLIM 1.230 iN
SLIM 1.300 iN
SLIM 1.400 iN
SLIM 1.490 iN
SLIM 1.620 iN
35
27,5
23
17
13,5
17
13,5
9,5
62,2
48,7
40
29,7
22,1
29,7
22,1
14,9
31,6
24,5
20,6
14,9
11,8
14,9
11,8
8,5
90,1
90
90,1
90
90,2
90
90,2
90,3
88,9
88,4
88,8
88,5
88,5
88,5
88,5
88,2
HH
HH
HH
HH
HH
HH
HH
HH
92,2
91,7
91,4
91,7
92,9
91,7
92,9
92,8
7,8
8,3
8,6
8,3
7,1
8,3
7,1
7,2
2,1
1,7
1,3
1,7
2,7
1,7
2,7
2,5
122
136
120
110
96
110
96
94
5,1
5,8
4,7
4,4
4
4,4
4
4,1
11,8
10,6
12,6
13,1
13,8
13,1
13,8
13,6
129
102
149
166
193
166
193
185
0,052
0,036
0,036
0,029
0,023
0,029
0,023
0,015
108,2
110,9
99,5
94,5
96
94,5
96
89,3
3
3,3
2,6
2,7
3
2,7
3
2,7
15,6
15,1
16,3
16,2
15,6
16,2
15,6
16,2
290
255
350
333
290
333
290
333
0,043
0,031
0,033
0,023
0,017
0,023
0,017
0,013
15
15
15
15
15
120
120
120
-
-
-
-
-
80
80
80
51AQ338
51AQ338
51AQ338
51AQ338
51AQ338
51AQ338
51AQ338
51AQ338
92/42/EEC MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating flue CO2 O2 exceeding flue flue CO2 O2 exceeding flue nominal nominal Certificate temp. number efficiency heat heat temp. air mass temp. air mass boiler pump EEC Pn 70°C 92/42/EEC losses losses and flow/rate and flow/rate Nr. kW kW kW kW % % % % % °C % % % kg/s °C % % % kg/s W W
Heat input
33
SLIM 2.300 i
PRODUCT
24,5
SLIM 2.230 i
92/42/EEC MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating flue CO2 O2 exceeding flue flue CO2 O2 exceeding flue nominal nominal Certificate temp. number efficiency heat heat temp. air mass temp. air mass boiler pump EEC Pn 70°C 92/42/EEC losses losses and flow/rate and flow/rate Nr. kW kW kW kW % % % % % °C % % % kg/s °C % % % kg/s W W
Heat input
26,3
LUNA3 1.240i
PRODUCT
26,3
LUNA3 240i
92/42/EEC MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating flue CO2 O2 exceeding flue flue CO2 O2 exceeding flue nominal nominal Certificate temp. number efficiency heat heat temp. air mass temp. air mass boiler pump EEC Pn 70°C 92/42/EEC losses losses and flow/rate and flow/rate Nr. kW kW kW kW % % % % % °C % % % kg/s °C % % % kg/s W W
PRODUCT
Product technical data gas boilers
83
Quality Environment Safety
Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations
36061 BASSANO DEL GRAPPA (VI) - ITALY Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 03-12 (E)