General catalogue Domestic Range

Page 1

General catalogue COMMERCIAL AND TECHNICAL INFORMATION Domestic Range


Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the highest technological standards. For over 30 years BAXI SPA has provided a wide range of cutting-edge solutions, anticipating market evolutions and paying attention to customer needs.

How to read this catalogue In this catalogue we show the complete range of BAXI products. On each page, in addition to the product benefits, there is a detailed list of the appliance characteristics, a technical chart, and coloured icons. These icons refer to the specific pages of the technical section of the catalogue where, by segment, the technical drawings and all the specific accessories are represented.

In the technical section you will find:

Dimensional Flue pipe technical accessories drawings Graphs Flue systems

2

Hydraulic accessories

Thermoregulation accessories

Other accessories


More details and information on the website By accessing to the www.baxi.it, Reserved Area and then to the Tech Area, just after a quick registration it is possible to display and download the following documents:

• Certifications • Fault Finding List • General Catalogues • General informations catalogues of all Baxi products • Instructions Manuals • PCB Service Instructions • Spare Parts Catalogues • Technical Drawings • Technical INFO

Index Gas condensing boilers Hybrid sistems

4 12

Gas boilers Wall hung boilers

14

Floor standing boilers

26

Solar systems

28

Indirect cylinders

30

Water heaters

36

Technical section

38

3


Gas condensing boilers Heating only and combi - Luna Platinum - Luna Duo-tec - Duo-tec Compact

05 06 07

With DHW ministorage - Duo-tec Max

08

Combi with DHW storage - Nuvola Platinum - Nuvola Duo-tec

09 10

Combi with DHW storage and solar integration - Luna3 Comfort HT Solar

4

11


Gas condensing boilers Technical pages 40-55 64-68 70-72 73-74 76-77

Luna Platinum

• Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting; supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Integrated control of a solar system* • Complete soundproofing of the generator • Full modulating circulating pump • Frontal access for advanced diagnostics Control panel

Modulation ratio

innovative removable control panel distinguished by a clear back-lighting and easiness of use, thanks to the navigation knob and two push-buttons dedicated to the set of the comfort and complete programming of the boiler.

the modulation system is able to adapt the heat output to the energy demanded by the building.

Hydraulic system 3 way electric diverter valve (also heating only models) Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Full modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Cascade installation option Room sensor, heating circuit and sanitary timers included in the control panel

Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

*in case of contemporary control of a solar system and a zone by the wallmounted control panel, it is necessary to install a programmable clip in/external module THINK.

Heating only▲

Combi 24 Product code Maximum DHW heat input

kW

Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60°C Maximum heating heat output 50/30°C Minimum heating heat output 80/60°C Minimum heating heat output 50/30°C

kW kW kW kW kW kW

33

1.12

1.18

1.24

1.32

7102695 7102703 7102665 7108435 7106583 7108436 24,7 34 20,6 24 20 21,8 2,4 2,7

28,9 33 28 30,6 3,3 3,6

12,4 12 13,1 2 2,2

17,4 16,9 18,4 2,4 2,7

24,7 24 26,1 2,4 2,7

33 32 34,9 3,2 3,5

★★★★

★★★★

★★★★

★★★★

★★★★

★★★★

109,8 97,7 105,8 107,7 5 -5 10/0,8 25/80 35/60

109,8 97,8 105,8 107,8 5 -5 8/0,8 25/80 35/60

109,8 97,7 105,8 107,7 5 -5 8/0,8 25/80 35/60

109,8 97,6 105,7 107,6 5 -5 8/0,8 25/80 35/60

109,8 97,6 105,7 107,6 5 -5 10/0,8 25/80 35/60

Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Nominal efficiency 80/60°C Nominal efficiency 50/30°C Efficiency 30% NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range. DHW temperature range DHW production ∆T 25°C (1)

°C l/bar °C °C

109,8 97,7 105,8 107,6 5 -5 8/0,8 25/80 35/60

l/min

13,8

18,9

-

-

-

-

Minimum capacity DHW flow rate Minimum pressure DHW circuit Maximum pressure heating circuit Maximum pressure DHW circuit Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature

l/min bar bar bar m m kg/s kg/s °C

2 0,15 3 8 10 80 0,012 0,001 80

2 0,15 3 8 10 80 0,016 0,002 80

3 10 80 0,006 0,001 75

3 10 80 0,008 0,001 75

3 10 80 0,012 0,001 80

3 10 80 0,016 0,002 80

Dimensions (h x w x d) Net weight Gas type Power consumption

mm kg

36

38

34,5

37,5

Grade of protection

% % % %

W

120

145

IPX5D

IPX5D

760 x 450 x 345 34,5 34,5 Natural Gas 108 122 IPX5D

IPX5D

120

130

IPX5D

IPX5D

(1) without flow restrictor. ▲

Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. See page 31 for sanitary performance.

5


Technical pages 40-55 64-68 70-72

Luna Duo-tec

74

76-77

• Digital control panel with back-lighted LCD display • Wide modulation ratio up to 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Modulating circulating pump • Complete soundproofing of the generator • Frontal access for advanced diagnostics • Integration with solar system option Diagnostics

Modulation ratio

on the control panel there is easy access for the diagnostics. With a USB connection it is possible to check single boilers or multiple boilers functions.

the modulation system is able to adapt the heat output to the energy demanded by the building.

3 way electric diverter valve (also heating only models) Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option

24

Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

28

40

1.12

1.24

1.28

Maximum DHW heat input

kW

24,7

28,9

34

41,2

-

-

-

Maximum heating heat input

kW

20,6

24,7

28,9

33

12,4

24,7

28,9

Maximum DHW heat output

kW

24

28

33

40

-

-

-

Maximum heating heat output 80/60°C

kW

20

24

28

32

12

24

28

Maximum heating heat output 50/30°C

kW

21,8

26,1

30,6

34,9

13,1

26,1

30,5

Minimum heating heat output 80/60°C

kW

3,4

3,8

4,7

5,7

2

3,4

4

Minimum heating heat output 50/30°C

kW

3,7

4,1

5,1

6,3

2,2

3,7

4,3

★★★★

★★★★

★★★★

★★★★

★★★★

★★★★

★★★★

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,7

97,7

97,7

97,7

97,8

97,6

97,6

Nominal efficiency 50/30°C

%

105,8

105,8

105,8

105,8

105,8

105,7

105,7

Efficiency 30%

%

107,6

107,6

107,7

107,7

107,8

107,6

107,6

5

5

5

5

5

5

5

-5

-5

-5

-5

-5

-5

-5

Energetic efficiency (92/42/CEE)

NOx class (EN 483) Minimum working temperature Heating temperature range. DHW temperature range

°C l/bar

8/0,8

8/0,8

10/0,8 10/0,8

8/0,8

8/0,8

8/0,8

°C

25/80

25/80

25/80

25/80

25/80

25/80

25/80

°C

35/60

35/60

35/60

35/60

35/60

35/60

35/60

DHW production ∆T 25°C (1)

l/min

13,8

16,1

18,9

22,9

-

-

-

Minimum capacity DHW flow rate

-

l/min

2

2

2

2

-

-

Minimum pressure DHW circuit

bar

0,15

0,15

0,15

0,15

-

-

-

Maximum pressure heating circuit

bar

3

3

3

3

3

3

3

Maximum pressure DHW circuit

bar

8

8

8

8

-

-

-

m

10

10

10

10

10

10

10

Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length

m

80

80

80

80

80

80

80

Maximum flue mass flow rate

kg/s

0,012

0,014

0,016

0,019

0,006

0,012

0,014

Minimum flue mass flow rate

kg/s

0,002

0,002

0,002

0,003

0,001

0,002

0,002

Maximum flue temperature

°C

80

80

80

80

75

80

80

Dimensions (h x w x d)

mm

Net weight

kg

38,5

38,5

39,5

34,5

36

760 x 450 x 345

Gas type Power consumption Grade of protection

6

33

7101931 7101932 7101933 7102871 7102852 7102853 7105684

Product code

Expansion vessel capacity/pre-charge

Control system

Heating only▲

Combi

Hydraulic system

41

34,5

Natural Gas/LPG W

102

114

133

142

108

102

114

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

(1) without flow restrictor. ▲

Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. See page 31 for sanitary performance.


Gas condensing boilers Technical pages 41-55 64-68 70-72

Duo-tec Compact

74

76-77

• Digital control panel with back-lighted wide LCD display • Wide modulation ratio up to 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Ultra compact dimensions (700x400x299 mm) • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Modulating circulating pump • Complete soundproofing of the generator Compact dimensions

Modulation ratio the modulation system is able to adapt the heat output to the energy demanded by the building.

Duo-tec Compact is ideal to be installed in narrow space thanks to its compact dimensions

Combi

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option

Product code

Heating only▲

24

1.24

7106765

7108974

Maximum DHW heat input

kW

24,7

-

Maximum heating heat input

kW

20,6

24,7

Maximum DHW heat output

kW

24

-

Maximum heating heat output 80/60°C

kW

20

24

Maximum heating heat output 50/30°C

kW

21,8

26,1

Minimum heating heat output 80/60°C

kW

3,4

3,4

Minimum heating heat output 50/30°C

kW

3,7

3,7

★★★★

★★★★

Average efficiency (DIN 4702-T8)

%

109,8

109,8

Nominal efficiency 80/60°C

%

97,7

97,6

Nominal efficiency 50/30°C

%

105,8

105,7

Efficiency 30%

%

107,6

107,6

Energetic efficiency (92/42/CEE)

NOx class (EN 483) Minimum working temperature

Control system

Expansion vessel capacity/pre-charge

Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

Heating temperature range. DHW temperature range

°C

5

5

-5

-5

l/bar

7/0,8

8/0,8

°C

25/80

25/80

°C

35/60

35/60

DHW production ∆T 25°C (1)

l/min

13,8

-

Minimum capacity DHW flow rate

-

l/min

2

Minimum pressure DHW circuit

bar

0,15

-

Maximum pressure heating circuit

bar

3

3

Maximum pressure DHW circuit

bar

8

-

m

10

10

Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length

m

80

80

Maximum flue mass flow rate

kg/s

0,011

0,012

Minimum flue mass flow rate

kg/s

0,002

0,002

Maximum flue temperature

°C

80

80

Dimensions (h x w x d)

mm

700x400x299

700 x 400 x 299

Net weight

kg

34

30

Gas type Power consumption Grade of protection

Natural Gas/LPG W

104

102

IPX5D

IPX5D

(1) without flow restrictor. ▲

Heating only models are connectable to UB-UB INOX 80/120 lt cylinder. page 31 for sanitary performance.

7


Technical pages 41-55 64-68 70-72

Duo-tec Max

74

76-77

• Digital control panel with back-lighted LCD display • Mini storage tank integrated in the expansion vessel (patented by Baxi) • *** DHW comfort (EN 13203) • Wide modulation ratio 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Circulating pump with modulation • Complete soundproofing of the generator • Frontal access for advanced diagnostics Modulation ratio

Sanitary comfort

the modulation system is able to adapt the heat output to the energy demanded by the building.

Thanks to the mini storage tank and to the enhanced plate heat exchanger, DHW is quickly available, at a constant temperature also with different flow rates

Combi with DHW integrated mini storage tank

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar

Product code

24

33

7102879

7102880

Maximum DHW heat input

kW

24,7

34

Maximum heating heat input

kW

20,6

28,9

Maximum DHW heat output

kW

24

33

Maximum heating heat output 80/60°C

kW

20

28

Maximum heating heat output 50/30°C

kW

21,8

30,6

Minimum heating heat output 80/60°C

kW

3,4

4,7

Minimum heating heat output 50/30°C

kW

3,7

5,1

★★★★

★★★★

Average efficiency (DIN 4702-T8)

%

109,8

109,8

Nominal efficiency 80/60°C

%

97,7

97,7

Nominal efficiency 50/30°C

%

105,8

105,8

Thermoregulation system

Effi ciency 30%

%

107,6

107,7

Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option

NOx class (EN 483)

Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Safety NTC sensor against flues overheat Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

Energetic effi ciency (92/42/CEE)

Minimum working temperature Expansion vessel capacity/pre-charge Mini storage tank capacity Heating temperature range. DHW temperature range

5

5

°C

-5

-5

l/bar

8/0,8

8/0,8

l

4

4

°C

25/80

25/80

°C

35/60

35/60

DHW production ∆T 25°C (1)

l/min

13,8

18,9

Minimum capacity DHW flow rate

l/min

2

2

bar

0,15

0,15

Minimum pressure DHW circuit Maximum pressure heating circuit

bar

3

3

Maximum pressure DHW circuit

bar

8

8 10

Coaxial flue system Ø 60/100 max length

m

10

Dual flue system Ø 80 max length

m

80

80

Maximum flue mass flow rate

kg/s

0,012

0,016

Minimum flue mass flow rate

kg/s

0,002

0,002

Maximum flue temperature

°C

80

80

Dimensions (h x w x d)

mm

760 x 450 x 345

760 x 450 x 345

Net weight

kg

38,5

39,5

Natural Gas/LPG

Natural Gas/LPG

Gas type Power consumption Grade of protection

8

(1) without flow restrictor.

W

102

133

IPX5D

IPX5D


Gas condensing boilers Technical pages 42-55 64-68 70-72 73-74 76-77

Nuvola Platinum

• Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting; supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Full modulating circulating pump • High DHW performances: up to 500 lt in 30 minutes (33 kW model) • Integrated sanitary expansion vessel • Frontal access for advanced diagnostics Control panel

Modulation ratio

innovative removable control panel distinguished by a clear back-lighting and easiness of use, thanks to the navigation knob and two push-buttons dedicated to the set of the comfort and complete programming of the boiler.

the modulation system is able to adapt the heat output to the energy demanded by the building.

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger Stainless steel AISI 316L tank Modulating fan with electronic speed adjusting system Automatic by-pass Full modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Tank relief valve set at 8 bar Integrated sanitary 2 litres expansion vessel Sanitary recirculation option

Thermoregulation system Integrated climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel

Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Anti legionella function Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

Combi with DHW storage

Product code

24

33

7107051

7107052

Maximum DHW heat input

kW

24,7

34

Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60°C Maximum heating heat output 50/30°C Minimum heating heat output 80/60°C Minimum heating heat output 50/30°C

kW kW kW kW kW kW

20,6 24 20 21,8 2,4 2,7

28,9 33 28 30,6 3,3 3,6

★★★★

★★★★

°C l/bar °C °C l l/bar l/min

109,8 97,7 105,8 107,6 5 -5 7,5/0,8 25/80 35/60 45 2/3,5 16,6

109,8 97,7 105,8 107,7 5 -5 7,5/0,8 25/80 35/60 45 2/3,5 19,5

DHW production at discharge ∆T 30°C (1)

l/min l/30’

13,8 385

18,9 500

Maximum pressure heating circuit Maximum pressure DHW circuit Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature

bar bar m m kg/s kg/s °C

3 8 10 80 0,012 0,001 80

3 8 10 80 0,016 0,002 80

Dimensions (h x w x d) Net weight Gas type Power consumption

mm Kg

950x600x466 62 Natural Gas 120

950x600x466 64 Natural Gas 145

IPX5D

IPX5D

Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Nominal efficiency 80/60°C Nominal efficiency 50/30°C Efficiency 30% NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge Heating temperature range DHW temperature range Tank capacity Tank expansion vessel capacity/pre-charge Specific flow rate (EN 625) DHW production ∆T 25°C (1)

Grade of protection

% % % %

W

(1) without flow restrictor.

9


Technical pages 42-55 64-68 70-72

Nuvola Duo-tec

74

76-77

• Digital control panel with back-lighted LCD display • Wide modulation ratio up to 1÷7: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Modulating circulating pump • High DHW performances: up to 385 lt in 30 minutes (∆T 30°C) • Stainless steel AISI 316L 45 lt cylinder • Frontal access for advanced diagnostics Diagnostics

Modulation ratio

on the control panel there is easy access for the diagnostics. With a USB connection it is possible to check single boilers or multiple boilers functions.

the modulation system is able to adapt the heat output to the energy demanded by the building.

Combi with DHW storage

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger Stainless steel AISI 316L tank Modulating fan with electronic speed adjusting system Automatic by-pass Modulating low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar Tank relief valve set at 8 bar Sanitary 2 litres expansion vessel available as optional Sanitary recirculation option

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option

Product code

24

7105982

7105983

Maximum DHW heat input

kW

16,5

24,7

Maximum heating heat input

kW

12,4

20,6

Maximum DHW heat output

kW

16

24

Maximum heating heat output 80/60°C

kW

12

20

Maximum heating heat output 50/30°C

kW

13,1

21,8

Minimum heating heat output 80/60°C

kW

2,2

3,4

Minimum heating heat output 50/30°C

kW

2,4

3,7

★★★★

★★★★

Average efficiency (DIN 4702-T8)

%

109,8

109,8

Nominal efficiency 80/60°C

%

97,8

97,7

Nominal effi ciency 50/30°C

%

105,8

105,8

Effi ciency 30%

%

107,8

107,6

Energetic efficiency (92/42/CEE)

NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge

5

5

°C

-5

-5 7,5/0,8

l/bar

7,5/0,8

Heating temperature range.

°C

25/80

25/80

DHW temperature range

°C

35/60

35/60

Tank capacity

l

45

45

l/bar

2/2,5

2/2,5

Specific flow rate (EN 625)

l/min

13,3

16,6

DHW production ∆T 25°C (1)

l/min

9,2

13,8

l/30’

275

385

Maximum pressure heating circuit

bar

3

3

Maximum pressure DHW circuit

bar

8

8

m

10

10

Control system

Tank expansion vessel capacity/pre-charge

Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Overheat limit thermostat against flues overheat Electronic temperatures control by NTC sensors Anti legionella function Full anti-frost device Electronic thermometer Digital heating circuit pressure gauge

DHW production at discharge ∆T 30°C

(1)

Coaxial flue system Ø 60/100 max length Dual flue system Ø 80 max length

m

80

80

Maximum flue mass flow rate

kg/s

0,008

0,012

Minimum flue mass flow rate

kg/s

0,001

0,002

Maximum flue temperature

°C

75

80

Dimensions (h x w x d)

mm

950x600x466

950x600x466

Net weight

Kg

62

62

Natural gas/LPG

Natural gas/LPG

Gas type Power consumption Grade of protection (1) without flow restrictor.

10

16

W

112

102

IPx5D

IPx5D


Gas condensing boilers Technical pages 43-55 64-68 70-72

Luna3 Comfort HT Solar

75

76-77

• Wide modulation ratio 1÷6: better and noiseless boiler working • 200 lt thermal stratification cylinder made of vitrified steel with solar integration • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Mixed system (low and high temperature) installation option • Built-in climatic regulation (outdoor sensor available as optional) • Controller, expansion vessel and hydraulic group for the solar system, integrated in the boiler casing Stratification cylinder

Modular installation

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L heat exchanger with sound proofing composite casing Stainless steel enhanced DHW exchanger to ensure condensation also in DHW mode 200 lt thermal stratification cylinder made of vitrified steel with solar integration through coil exchanger Modulating fan with electronic speed adjusting system Automatic by-pass Multi-speeds low energy pump of the heating circuit with built-in air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Circulating pump for the cylinder Cylinder expansion vessel Solar expansion vessel Solar hydraulic group (pump, safety valve, flow rate regulator, air vent) Thermostatic mixing valve on the DHW outlet of the cylinder Sanitary recirculation option

Thermoregulation system Solar controller (pump and two temperature sensors) Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, central heating and sanitary timers included in the control panel

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in the event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Anti-legionella function Full anti-frost device Thermometer of the cylinder Heating circuit electronic thermometer Heating circuit pressure gauge

The 200 litres cylinder with thermal stratification grants a fast heating of the sanitary water through an enhanced plates exchanger, ensuring high performance and constant availability of domestic hot water.

Luna3 Comfort HT Solar has been designed to grant the maximum installation flexibility also in narrow spaces. It is possible to install the boiler separately from the cylinder.

Combi with DHW storage and solar integration 120-120 MS*

240-240 MS*

Product code Maximum DHW heat input

HLZ kW

71413001-71413011 12,4

71411691-71412971 24,7

Maximum heating heat input Maximum DHW heat output Maximum heating heat output 80/60 °C Maximum heating heat output 50/30 °C Minimum heat output 80/60 °C Minimum heat output 50/30 °C

kW kW kW kW kW kW

12,4 12 12 13 2** 2,2**

20,5 24 20 21,6 4 4,3

°C l/bar

★★★★ 109,8 97,6 105,1 108 5 -5 8/0,5

★★★★ 109,8 97,6 105,1 107,5 5 -5 8/0,5

Solar expansion vessel capacity / pre-charge l Heating temperature range °C DHW temperature range °C Cylinder capacity l Cylinder expansion vessel capacity / pre-charge l Specific flow rate (EN 625) l/min DHW production ∆T 25°C (1) l/min

18/2,5 20/80 35/60 200 8/3,5 18,5 6,9

18/2,5 20/80 35/60 200 8/3,5 27 13,8

Maximum pressure heating circuit Maximum pressure DHW circuit Maximum pressure DHW solar circuit Coaxial flue system Ø 60/100 max length Duel flue system Ø 80 max length Maximum flue mass flow rate Minimum flue mass flow rate Maximum flue temperature

bar bar bar m m kg/s kg/s °C

3 8 6 10 80 0,006 0,002 73

3 8 6 10 80 0,012 0,002 73

Dimensions (h x w x d) Net weight Gas type

mm kg

Energetic efficiency (92/42/CEE) Average efficiency (DIN 4702-T8) Minimum heat output 80/60 °C Minimum heat output 50/30 °C Energetic efficiency 30% Nox class (EN 483) Minimum working temperature Expansion vessel capacity / pre-charge

Power consumption Grade of protection

% % % %

2056x600x640 170-194 (MS) 170-194 (MS) Nat. gas / LPG

W

297-497 (MS)

297-497 (MS)

IPX5D

IPX5D

(1) without flow restrictor. * Model with mixed system supplied with the boiler. **Boiler working with Natural gas. In case of LPG convertion the minimum output is 3,9 kW (80/60°C) and 4,2 kW (50/30°C)

11


Hybrid Systems - Luna Platinum CSI

12

13


Hybrid Systems Technical pages

Luna Platinum CSI

43

The integrated hybrid system consists of: • A condensing gas boiler (3,3 – 33 kW) • A 6 or 8 or 11 kW electric heat pump (depending on the building loads) • A solar thermal system (two 2,5 sqm collectors) • A 300 lt stainless steel integrated cylinder with solar coil • Built-in control of mixed systems: 1 high temperature zone + 2 low temperature zones (independent temperatures) Luna Platinum CSI

Luna Platinum CSI (Complete System Integration)

is an integrated multi-energy and multitechnology system for home comfort. It combines various technologies: solar system, water/air heat pump, gas condensing boiler

is an integrated COMPACT system which combines heating technologies and energy sources to provide energy efficient complete integrated systems and grant maximum comfort (with water production for heating, DHW and cooling), indipendently from outside weather conditions.

Combi with storage and solar integration (buffer tank)

Features • Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting • Control of solar system integration • Control of low temperature system • Outside temperature check related to heat pump control • Outdoor sensor • Modulation ratio up to 1:10: highest efficiency in low heat demand installations • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Built-in solar system integration • Complete soundproofing of the generator • Circulating pump with full modulation • Frontal access for advanced diagnostics • Heating expansion vessel: 24 lt + 6 lt for cooling • Solar expansion vessel: 18 lt • Anti-legionella system not necessary as the cylinder contains primary water • Specific flow rate ∆t 30°C; 27 l/min*

Product code

633

833

1133

710799401 (with 6 kw h.p.)

710799501 (with 8 kw h.p.)

710874701 (with 11 kw h.p.)

Maximum DHW heat input

kW

34

Maximum heating heat input Range of DHW heat output Range of heating heat output Energetic efficiency (92/42/CEE) DHW production ∆T 30°C

kW kW kW

28,9 3,3-33 3,3-28

Dimensions h x w x d

★★★★

lt/min

27

mm

2060x868x672

Integrable heating pumps

RO.6/1.BT

RO.8/1.BT

RO.11/3.BT

kW

6,80

8,45

11,2

COP ¹ Nominal cooling output ² EER ²

kW

3,90 6,7 3,2

4,00 8,7 3,0

4,4 9,5 3,0

Dimensions hxwxd

mm

735x1190x340

735x1190x340

1235x1190x340

Nominal heating capacity ¹

(1) Outdoor air temperature 7°C (d.b.)/6°C (w.b) and flow temperature 35°C (2) Outdoor air temperature 35°C (d.b.) and flow temperature 18°C

* l/min water at the tap

13


Gas boilers Wall hung boilers Heating only and combi - Luna3 Comfort - Luna3

15 16

Outdoor installation - Luna3 Comfort Air

17

Low NOx - Luna3 Blue

18

With micro storage - Luna3 Comfort Max

19

With storage - Nuvola3 Comfort - Nuvola3 BS

20 21

Outdoor installation - Luna3 Silver Space

22

Ultra compact dimensions - Ecofour - Fourtech - Mainfour

23 24 25

Floor standing boilers Heating only and combi with storage - Slim

26

Heating only - Slim HP

14

27


Gas boilers Technical pages 44-57 65-68 70-72

Luna3 Comfort

75

76-77

• Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Enhanced heat exchanger • Hydraulic group made of brass and flowmeter with turbine (combi models) • Sanitary pre-heating function • Connection to Baxi integrated solar systems option

Enhanced heat exchanger

Connection to solar systems

Made of copper pipes protected with anticorrosion coating. It has a wide surface of exchange.

Electronics has been designed to allow the boiler to turn on only when the cylinder temperature is lower than the one requested.

Combi Fanned flue

Hydraulic system

240 Fi (1)

3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger (combi models) Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Product code

Natural Gas LPG

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel Sanitary timer (indirect cylinder)

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge (1)

In the heating only models, the electric motor is available as optional.

45624358 45624158

310 Fi

240 i

Open flue

Fanned flue 1.240 Fi

45631358 45224358 45524358 45631158 CSZ 45224158

1.310 Fi

1.240 i

45531358 45531158

45124358

Maximum heat input

kW

26,9

33,3

26,3

26,9

33,3

26,3

Minimum heat input

kW

10,6

11,9

10,6

10,6

11,9

10,6

Maximum heat output

kW

25

31

24

25

31

24

Minimum heat output

kW

9,3

10,4

9,3

9,3

10,4

9,3

Maximum efficiency

%

91,2

Energetic efficiency (92/42/CEE) Efficiency at 30%

Thermoregulation system

CSE

Heating only* Open flue

Minimum working temperature

%

92,9

93,1

91,2

92,9

93,1

★★★

★★★

★★

★★★

★★★

★★

90,2

90,8

90,29

90,2

90,8

90,29

°C

-5

-5

-5

-5

-5

-5

Expansion vessel/pre-charge

l/bar

8/0,5

10/0,5

8/0,5

8/0,5

10/0,5

8/0,5

Heating system max pressure

bar

3

3

3

3

3

3

Regulation of water temperature in heating circuit

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit

°C

35/60

35/60

35/60

35/60

35/60

35/60

DHW production ∆T 25°C

l/min

14,3

18

13,7

-

-

-

Minimum capacity DHW flow rate

l/min

2

2

2

-

-

-

Minimum pressure on DHW circuit

bar

0,15

0,15

0,15

-

-

-

Maximum pressure on DHW circuit

bar

8

8

8

-

-

-

Flue tube

Ø mm

-

-

120

-

-

120

Coaxial flue system Ø 60/100

m

5

4

-

5

4

-

Dual flue system Ø 80 max length

m

40

25

-

40

25

-

Maximum flue mass flow rate

kg/s

0,017

0,018

0,019

0,017

0,018

0,019

Minimum flue mass flow rate

kg/s

0,017

0,019

0,017

0,017

0,019

0,017

Maximum flue temperature

°C

135

145

110

135

145

110

Dimensions (h x w x d)

mm

Net weight

kg

38

40

38

31

730x400x299

Gas type Power consumption Grade of protection

33

36

Natural Gas/LPG W

135

165

80

135

165

80

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

* Heating only models are connectable to combi 80 lt/UB-UB INOX 80/120 lt. page 31 for sanitary performance.

15


Technical pages 44-57 65-68 70-72

Luna3

75

76-77

• Digital control panel with wide LCD display • Enhanced heat exchanger • Hydraulic group made of brass and flowmeter with turbine (combi models) • Sanitary pre-heating function • Connection to Baxi integrated solar systems option • Built-in climatic regulation (outdoor sensor available as optional)

Wide LCD display

Hydraulic group made of brass

The interaction with the boiler is easier thanks to information clearly displayed in the wide LCD display and dedicated push-buttons for setting and regulation.

Luna3 is provided with 3 way electric valve. Thanks to the flowmeter with turbine, the sanitary water is detected and gauged.

Heating only*

Combi

Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger (combi models) Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Open flue

Fanned flue

Hydraulic system 240 Fi Product code

Natural Gas LPG

CSB

280 Fi

310 Fi

45624366 CSE 45628366 45631366 45631166 45624166

Fanned flue

240 i

1.310 Fi

45224366 45224166

45531366 45531166

Maximum heat input

kW

26,9

30,1

33,3

26,3

33,3

Minimum heat input

kW

10,6

11,9

11,9

10,6

11,9

Maximum heat output

kW

25

28

31

24

31

Minimum heat output

kW

9,3

10,4

10,4

9,3

10,4

Maximum efficiency

%

92,9

93,1

93,1

91,2

93,1

★★★

★★★

★★★

★★

★★★

%

90,2

90,8

90,8

90,29

90,8

°C

-5

-5

-5

-5

-5

8/0,5

10/0,5

10/0,5

8/0,5

10/0,5

Thermoregulation system

Energetic efficiency (92/42/CEE)

Two heating temperatures possible ranges: 30/85°C, 30/45°C Remote controller and climatic regulator option Built-in climatic regulation (outdoor sensor available as optional)

Efficiency at 30% Minimum working temperature Expansion vessel/pre-charge

l/bar

Heating system max pressure

bar

3

3

3

3

3

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge

Regulation of water temperature in heating circuit Regulation of water temperature in DHW circuit

°C

35/60

35/60

35/60

35/60

35/60

DHW production ∆T 25°C

l/min

14,3

16

18

13,7

-

Minimum capacity DHW flow rate

l/min

2

2

2

2

-

Minimum pressure on DHW circuit

bar

0,15

0,15

0,15

0,15

-

Maximum pressure on DHW circuit

bar

8

8

8

8

-

Flue tube Coaxial flue system Ø 60/100 Dual flue system Ø 80 max length

Ø mm

-

-

-

120

-

m

5

4

4

-

4

m

40

25

25

-

25

Maximum flue mass flow rate

kg/s

0,017

0,017

0,018

0,019

0,018

Minimum flue mass flow rate

kg/s

0,017

0,017

0,019

0,017

0,019

Maximum flue temperature

°C

135

140

145

110

145

Dimensions (h x w x d)

mm

Net weight

kg

38

40

33

38

760x450x345

Gas type Power consumption Grade of protection

40 Natural Gas/LPG

W

135

165

165

80

165

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

* Heating only models are connectable to UB-UB INOX 80/120 lt. See page 31 for sanitary performance.

16


Gas boilers

Luna3 Comfort Air

Technical pages 45-57 65-68 70-72

75

76-77

• Remote control (WIRELESS data transmission) with LCD display, room thermostat heating and sanitary timer function included • Outdoor installation in partially protected places thanks to the grade of protection IPX5D and to the possibility of functioning up to -15°C • Enhanced heat exchanger • Sanitary pre-heating function • Connection to Baxi integrated solar systems option

WIRELESS remote control

OUTDOOR installation

It allows a complete managing of the domestic comfort from inside. The WIRELESS transmission that occurs between the boiler and the remote control makes installation process easier since electric connections between the boiler and the remote control are not necessary.

In partially protected places thanks to the grade of protection IPX5D and to the possibility of functioning up to -15°C

Hydraulic system 3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel sanitary exchanger Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Combi Fanned flue 250 Fi

310 Fi

CSB

45625369 45625169

45631369 45631169

Maximum heat input

kW

26,9

33,3

Minimum heat input

kW

10,6

11,9

Maximum heat output

kW

25

31

Minimum heat output

kW

9,3

10,4

Thermoregulation system

Maximum efficiency

%

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel

Energetic efficiency (92/42/CEE)

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge

Product code

Natural Gas LPG

92,9

93,1

★★★

★★★ 90,8

Efficiency at 30%

%

90,2

Minimum working temperature

°C

-15

-15

Expansion vessel/pre-charge

l/bar

8/0,5

10/0,5

Heating system max pressure

bar

3

3

°C

30/85 30/45

30/85 30/45

Regulation of water temperature in heating circuit

°C

35/60

35/60

DHW production ∆T 25°C

Regulation of water temperature in DHW circuit

l/min

14,3

18

Minimum capacity DHW flow rate

l/min

2

2

Minimum pressure on DHW circuit

bar

0,15

0,15

Maximum pressure on DHW circuit

8

bar

8

Coaxial flue system Ø 60/100

m

5

4

Dual flue system Ø 80 max length

m

40

25

Maximum flue mass flow rate

kg/s

0,017

0,018

Minimum flue mass flow rate

kg/s

0,017

0,019

Maximum flue temperature

°C

135

145

Dimensions (h x w x d)

mm

Net weight

kg

763x450x345 38

Gas type Power consumption Grade of protection

40 Natural Gas/LPG

W

135

165

IPX5D

IPX5D

17


Technical pages 46-57 65-68 70-72

Luna3 Blue

75

76-77

• Low NOx burner-Class NOx 5 • Constant efficiency at over 93% for all heat inputs (fanned flue models) • Hydraulic group made of brass and flowmeter with turbine (combi models) • Sanitary pre-heating function • Connection to Baxi integrated solar systems option

Low NOx burner

Constant efficiency

The burner has been designed to grant NOx emissions lower than 10mg/kWh

Constant efficiency at over 93% for all heat inputs (fanned flue models)

Hydraulic system 3 way electric diverter valve Water refrigerated Low NOx burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW exchanger (combi models) Modulating fan with electronic speed adjusting system (fanned flue models) Automatic by-pass Multi-speeds low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Combi Fanned flue 240Fi

280Fi

180i

240i

1.240Fi

1.180i

45628366

45218366

45224366

45524366

45118366

Maximum efficiency

%

93,2

93,1

90,3

90,3

93,2

90,3

Minimum heat input

kW

11,9

11,9

10,6

11,9

11,9

10,6

Maximum heat output

kW

24

28

17,5

24

24

17,5

Minimum heat output

kW

10,7

10,7

9,3

10,4

10,7

9,3

Maximum efficiency

%

92,9

91,2

Energetic efficiency (92/42/CEE)

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Remote controller and climatic regulator (supplied as optional)

Minimum working temperature

%

92,9

93,1

91,2

★★★

★★★

★★

★★

★★★

★★

91,2

92,5

89,6

89,6

91,2

89,6

°C

-5

-5

-5

-5

-5

-5

Expansion vessel/pre-charge

l/bar

8/0,5

10/0,5

8/0,5

8/0,5

8/0,5

8/0,5

Heating system max pressure

bar

3

3

3

3

3

3

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in heating circuit Regulation of water temperature in DHW circuit

°C

35/60

35/60

35/60

35/60

35/60

35/60

DHW production ∆T 25°C

l/min

13,7

16

10

13,7

-

-

Minimum capacity DHW flow rate

l/min

2

2

2

2

-

-

Minimum pressure on DHW circuit

bar

0,15

0,15

0,15

0,15

-

-

Maximum pressure on DHW circuit

bar

8

8

8

8

-

-

Ø mm

-

-

110

130

-

110

Coaxial flue system Ø 60/100

Flue tube

m

4

4

-

-

4

-

Dual flue system Ø 80 max length

m

20

20

-

-

20

-

Maximum flue mass flow rate

kg/s

0,018

0,017

0,015

0,009

0,018

0,015

Minimum flue mass flow rate

kg/s

0,015

0,014

0,012

0,035

0,015

0,012

Maximum flue temperature

°C

135

140

120

120

135

100

Dimensions (h x w x d)

mm

Net weight

kg

41,5

42

31

39,5

29

760x450x345

Gas type Power consumption Grade of protection

33

Natural Gas/LPG W

135

165

110

110

135

110

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

*Heating only models are connectable to UB-UB INOX 80/120 lt. page 31 for sanitary performance.

18

Open flue

45624366

Efficiency at 30%

Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Chimney sweeper function Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge

Open flue

ESB

Product code

Thermoregulation system

Control system

Heating only* Fanned flue


Gas boilers

Luna3 Comfort Max

Technical pages 46-57 65-68 70-72

75

76-77

• Micro storage tank integrated in the expansion vessel (patented Baxi) and ***DHW comfort (EN 13203) • Enhanced heat exchanger • Hydraulic group made of brass and flowmeter with turbine (combi models) • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions

Integrated micro storage tank

Sanitary comfort Thanks to the micro storage tank and to the enhanced plate heat exchanger, DHW is quickly available, at a constant temperature also with different flow rates

The special expansion vessel with integrated micro storage, grants DHW always at your disposal, to satisfy, without waiting times any sanitary demand.

Hydraulic system 3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Automatic by-pass Multi-speeds low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Combi with DHW micro-storage Fanned flue

Open flue

250Fi

310Fi

240 i

Product code

CSB

45825358

45831358

45324358

Maximum heat input

kW

26,9

33,3

26,3

Minimum heat input

kW

10,6

11,9

10,6

Maximum heat output

kW

25

31

24

Minimum heat output

kW

9,3

10,4

9,3

Thermoregulation system

Maximum efficiency

%

92,9

93,1

91,2

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as option) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel

Energetic efficiency (92/42/CEE)

★★★

★★★

★★

90,2

90,8

90,29

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge

Efficiency at 30% Minimum working temperature

% °C

-5

-5

-5

Expansion vessel/pre-charge

l/bar

8/0,5

8/0,5

8/0,5

Micro storage tank capacity

l

3,5

3,5

3,5

°C

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in heating circuit

°C

35/60

35/60

35/60

DHW production ∆T 25°C

Regulation of water temperature in DHW circuit

l/min

14,3

18

13,7

Minimum capacity DHW flow rate

l/min

2

2

2

Minimum pressure on DHW circuit

bar

0,15

0,15

0,15

bar

8

8

8

Ø mm

-

-

120 -

Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100

m

5

4

Dual flue system Ø 80 max length

m

40

25

-

Maximum flue mass flow rate

kg/s

0,017

0,018

0,019

Minimum flue mass flow rate

kg/s

0,017

0,019

0,017

Maximum flue temperature

°C

135

145

110

Dimensions (h x w x d)

mm

Net weight

kg

760x450x345 33

Gas type Power consumption Grade of protection

38

40

Natural Gas/LPG W

135

165

80

IPX5D

IPX5D

IPX5D

19


Technical pages 47-57 65-68 70-72

Nuvola3 Comfort

75

76-77

• Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • High sanitary performances: up to 490 lt in 30 min (∆T 30°C) • 60 lt stainless steel cylinder • Built-in sanitary expansion vessel

High performance

Built-in expansion vessel

Nuvola3 Comfort is the range with integrated storage which grants high sanitary performance and it represents the ideal solution in case of simultaneous big hot water demands.

Nuvola3 Comfort is provided with a built-in sanitary expansion vessel which represents the ideal solution in case of high pressures on the mains sanitary water.

Hydraulic system 3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating 60 lt stainless steel AISI 316L cylinder Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Built-in sanitary 2 litres expansion vessel Sanitary recirculation option

Thermoregulation system Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel

Combi with DHW storage Fanned flue 240 Fi

280 Fi

320 Fi

240 i

280 i

CSB

45714358

45724358 45724158

45728358 45728158

45732358 45732158

45424358

45428358

Maximum heat input

kW

15,3

26,3

30,1

34,5

27,1

31,1

Minimum heat input

kW

6,9

11,9

11,9

11,9

11,9

11,9

Maximum heat output

kW

14

24,4

28

32

24,4

28

Minimum heat output

kW

6

10,4

10,4

10,4

10,4

10,4

Maximum efficiency

%

90,9

92,9

93,1

93,2

90,2

90,6

%

★★ 88,3

★★★ 90,4

★★★ 90,5

★★★ 90,5

★★ 89,4

★★ 89,5

Product code

Natural Gas LPG

Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature

°C

-5

-5

-5

-5

-5

-5

Expansion vessel/pre-charge

l/bar

7,5/0,5

7,5/0,5

7,5/0,5

7,5/0,5

7,5/0,5

7,5/0,5

Heating system max pressure

bar

3

3

3

3

3

3

Regulation of water temperature in heating circuit

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit

°C

35/65

35/65

35/65

35/65

35/65

35/65

l

60

60

60

60

60

60

l/bar

2/3,5

2/3,5

2/3,5

2/3,5

2/3,5

2/3,5

Cylinder capacity

Control system

Cylinder expansion vessel capacity/pre-charge

Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Anti-legionella function Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge

Specific flow according to EN 625 DHW production ∆T 25°C

(1)

DHW production at discharge ∆T 30°C Maximum pressure on DHW circuit Flue tube

(1)

l/min

14,1

18,2

19

21,5

18,2

19

l/min

8,1

14

16,1

18,3

14

16,1

l/30’

260

390

450

490

390

450

bar

8

8

8

8

8

8

Ø mm

-

-

-

-

140

140

Coaxial flue system Ø 60/100

m

5

4

4

4

-

-

Dual flue system Ø 80 max length

m

30

30

30

30

-

-

Maximum flue mass flow rate

kg/s

0,015

0,018

0,018

0,022

0,022

0,024

Minimum flue mass flow rate

kg/s

0,015

0,017

0,018

0,021

0,021

0,021

Maximum flue temperature

°C

120

134

142

142

110

115

Dimensions (h x w x d)

mm

Net weight

kg

70

70

60

60

950x600x466

Gas type Power consumption Grade of protection (1)

20

Open flue

140 Fi

Without flow restrictor.

70

70

Natural Gas/LPG W

190

190

190

190

110

110

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D


Gas boilers

Nuvola3 BS

Technical pages 47-57 65-68 70-72

75

76-77

• 30 lt thermal dynamic stratification cylinder: - immediate DHW delivery thanks to 30 lt storage ready to be used at the needed temperature - less scale formation thanks to the DHW plates exchanger - high sanitary performances thanks to high efficiency of heat exchanger • Vertical hydraulic connections for easier replacement of existing boilers • Digital control panel with wide LCD display with text and symbols clearly showed • Up to 400 litres DHW production in 30’ (∆T 30°C) Wide LCD display

any scale formation is blocked thanks to the direct DHW exchange through the plates exchanger

With dedicated push-buttons for programming and regulation, for a clear display of the information

Hydraulic system 3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating 30 lt vitrified stratification cylinder Automatic by-pass Low energy pump with automatic air vent System to prevent pump and 3 way valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar Cylinder relief valve set at 8 bar Sanitary recirculation option

Thermoregulation system Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional) Remote controller and climatic regulator (supplied as optional) Control of multi-zones system option

Combi with DHW storage Fanned flue

Product code

Natural Gas LPG

Open flue

140 Fi

240 Fi

280 Fi

240 i

280 i

CSB

45714351 45714151

45724351 45724151

45728351 45728151

45424351 45424151

45428351 45428151

Maximum heat input

kW

15,3

26,3

30,1

27,1

31,1

Minimum heat input

kW

6,9

11,9

11,9

11,9

11,9

Maximum heat output

kW

14

24,4

28

24,4

28

Minimum heat output

kW

6

10,4

10,4

10,4

10,4

Maximum efficiency

%

90,9

92,9

93,1

90,2

90,6

%

★★ 88,3

★★★ 90,4

★★★ 90,5

★★ 89,4

★★ 89,5

Energetic efficiency (92/42/CEE) Efficiency at 30%

°C

-5

-5

-5

-5

-5

Expansion vessel/pre-charge

Minimum working temperature

l/bar

7/0,5

7,5/0,5

7,5/0,5

7,5/0,5

7,5/0,5

Heating system max pressure

bar

3

3

3

3

3

Regulation of water temperature in heating circuit

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit

°C

35/65

35/65

35/65

35/65

35/65

l

30

30

30

30

30

10,9

14,9

16,7

14,9

16,7

Cylinder capacity

Control system

Specific flow according to EN 625

l/min

Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in the event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Full anti-frost device Anti-legionella function Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge

DHW production ∆T 25°C (1)

l/min

8,1

14

16,1

14

16,1

DHW production at discharge ∆T 30°C (1)

l/30’

230

350

400

350

400

bar

8

8

8

8

8

Ø mm

-

-

-

140

140

Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100

m

5

4

4

-

-

Dual flue system Ø 80 max length

m

30

30

30

-

-

Maximum flue mass flow rate

kg/s

0,015

0,017

0,018

0,022

0,024

Minimum flue mass flow rate

kg/s

0,015

0,018

0,018

0,021

0,021

Maximum flue temperature

°C

120

134

142

110

115

Dimensions (h x w x d)

mm

Net weight

kg

63

63

53

53

950x600x466

Gas type Power consumption Grade of protection (1)

63 Natural Gas/LPG

W

190

190

215

140

165

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

Without flow restrictor.

21


Luna3 Silver Space

Technical pages 48-57 65-68 70-72

75

76-77

• Outdoor installation, minimum working temperature: -15°C • Remote control with LCD display supplied with the boiler; it includes room thermostat, heating and sanitary timers functions • Automatic filling of the heating system • Connection to Baxi integrated solar systems option

Outdoor installation

Automatic filling of the heating system

Ideal for outdoor installation thanks to the minimum working temperature -15°C, grade of protection IPX5D and anti-frost device.

For a perfect managing of the boiler without manual intervention to fill of the system.

Hydraulic system 3 way electric diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy pump with automatic air vent System to prevent pump and diverter valve sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Thermoregulation system Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as option) Control of multi-zones system option Room sensor, heating circuit and sanitary timers included in the control panel

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer AFR system, patented by Baxi that allows the efficiency optimization thanks to a perfect inlet air regulation (fanned flue models with dual flue system) Heating circuit pressure gauge

Combi Fanned flue 250 Fi

310 Fi

CSB

45625367 45625167

45631367 45631167

Maximum heat input

kW

26,9

33,3

Minimum heat input

kW

10,6

11,9

Maximum heat output

kW

25

31

Minimum heat output

kW

9,3

10,4

Maximum efficiency

%

Product code

Natural Gas LPG

Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature Expansion vessel/pre-charge Heating system max pressure

% °C l/bar

92,9

93,1

★★★ 90,2

★★★ 90,8

-15

-15

8/0,5

8/0,5

bar

3

3

°C

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit DHW production ∆T 25°C

°C l/min

35/60 14,3

35/60 18

Regulation of water temperature in heating circuit

Minimum capacity DHW flow rate

l/min

2

2

Minimum pressure on DHW circuit

bar

0,15

0,15

Maximum pressure on DHW circuit

8

bar

8

Coaxial flue system Ø 60/100

m

5

4

Dual flue system Ø 80 max length

m

40

25

Maximum flue mass flow rate

kg/s

0,017

0,018

Minimum flue mass flow rate

kg/s

0,017

0,019

Maximum flue temperature

°C

135

145

Dimensions (h x w x d)

mm

Net weight

kg

830x550x250 40,5

Gas type Power consumption Grade of protection

22

42 Natural Gas/LPG

W

135

165

IPX5D

IPX5D


Gas boilers

Ecofour

Technical pages 48-57 65-68 70-72

• • • • • •

Control panel Thanks to the control panel with knobs and LCD display, you can easily select temperatures and control the diagnostics.

Ecofour is ideal to be installed in narrow space thanks to its compact dimensions

Combi Fanned flue

Hydraulic system 3 way diverter valve Steel burner Primary exchanger made of copper pipes protected with anticorrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy circulating pump with automatic air vent System to prevent pump and diverter 3 way electric valve operating every 24 hours Heating circuit relief valve set at 3 bar

Efficiency at 30%

Thermoregulation system

Expansion vessel capacity/pre-charge

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation(outdoor sensor available as optional)

Heating system max pressure Regulation of water temperature in heating circuit Regulation of water temperature in DHW circuit

Product code

CSE

Heating only* Open flue

Fanned flue

Open flue

24 F

24

1.24 F

1.14 F

1.24

1.14

46624354

46224354

46524354

46514354

46124354

46114354

Maximum heat input

kW

25,8

26,3

25,8

15,1

26,3

15,4

Minimum heat input

kW

10,6

10,6

10,6

7,1

10,6

7,1

Maximum heat output

kW

24

24

24

14

24

14

Minimum heat output

kW

9,3

9,3

9,3

6,0

9,3

6,0

Maximum efficiency

%

92,93

91,20

92,93

92,50

91,20

90,90

★★★

★★

★★★

★★★

★★

★★

90,37

89,30

90,37

89,80

89,30

88,60

Energetic efficiency (92/42/CEE) Minimum working temperature

Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Heating circuit pressure gauge

76-77

Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Hydraulic group made of brass with electric 3 way valve DHW production through stainless steel plate exchanger Full anti-frost device Outdoor sensor option

Compact dimensions

Control system

75

Maximum capacity of the heating system

% °C

-5

-5

-5

-5

-5

-5

l/bar

6/0,5

6/0,5

6/0,5

6/0,5

6/0,5

6/0,5

l

100

100

100

100

100

100

bar

3

3

3

3

3

3

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

°C

35/60

35/60

5/60

5/60

5/60

5/60

Specific flow according to EN 625

l/min

10.7

10,7

-

-

-

-

DHW production ∆T 25°C

l/min

13,7

13,7

-

-

-

-

Minimum capacity DHW flow rate

l/min

2,0

2,0

-

-

-

-

Maximum pressure on DHW circuit

bar

8

8

-

-

-

-

Flue tube

Ø mm

-

120

-

-

120

110

Coaxial flue system Ø 60/100 max length

m

5

-

5

5

-

-

Dual flue system Ø 80 max length

m

30

-

30

30

-

-

Maximum flue mass flow rate

kg/s

0,014

0,020

0,014

0,012

0,020

0,014

Minimum flue mass flow rate

kg/s

0,014

0,018

0,014

0,012

0,018

0,013

Maximum flue temperature

°C

146

110

149

115

110

99

Dimensions (h x w x d)

mm

Net weight

kg

33

29

28

26

IPX5D

IPX5D

730x400x299

Gas type Grade of protection

32

31

Natural gas/LPG IPX5D

IPX5D

IPX5D

IPX5D

*Heating only models are connectable to UB-UB INOX 80/120 lt. page 31 for sanitary performance.

23


Fourtech

Technical pages 49-57 65-68 70-72

75

76-77

• • • • •

Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Compact hydraulic group with electric 3 way valve DHW production through stainless steel plate exchanger Extractable filter on the CH return circuit to protect the primary exchanger from impurities • Full anti-frost device • Outdoor sensor option

Compact dimensions

Control panel Thanks to the control panel with knobs and LCD display, you can easily select temperatures and control the diagnostics.

Fourtech, distinguished by compact dimensions (730x400x299 mm), is ideal to be installed in narrow space

Combi Fanned flue

Hydraulic system Product code

Natural Gas LPG

3 way electric valve Steel burner Primary exchanger made of copper pipes protected with anti-corrosion coating Stainless steel DHW heat exchanger Automatic by-pass Low energy circulating pump with automatic air vent System to prevent pump and 3 way electric valve operating every 24 hours Heating circuit relief valve set at 3 bar

Efficiency at 30%

Thermoregulation system

Expansion vessel capacity/pre-charge

Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation(outdoor sensor available as optional)

Control system Overheat limit thermostat to protect primary exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (fanned flue models) Flue thermostat to ensure safe discharge of flue products (open flue models) Electronic thermometer Heating circuit pressure gauge

CSB

Heating only* Open flue

Open flue

24 F

24

1.24 F

1.14 F

1.24

1.14

46624368 46624168

46224368 46224168

46524368

46514368

46124368

46114368

Maximum heat input

kW

25,8

26,3

25,8

15,1

26,3

15,4

Minimum heat input

kW

10,6

10,6

10,6

7,1

10,6

7,1

Maximum heat output

kW

24

24

24

14

24

14

Minimum heat output

kW

9,3

9,3

9,3

6,0

9,3

6,0

Maximum efficiency

%

92,93

91,20

92,93

92,50

91,20

90,90

★★★

★★

★★★

★★★

★★

★★

90,37

89,30

90,37

89,80

89,30

88,60

Energetic efficiency (92/42/CEE) Minimum working temperature Maximum capacity of the heating system

% °C

-5

-5

-5

-5

-5

-5

l/bar

6/0,5

6/0,5

6/0,5

6/0,5

6/0,5

6/0,5 100

l

100

100

100

100

100

Heating system max pressure

bar

3

3

3

3

3

3

Regulation of water temperature in heating circuit

°C

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit

°C

35/60

35/60

5/60

5/60

5/60

5/60

Specific flow according to EN 625

l/min

10.7

10,7

-

-

-

-

DHW production ∆T 25°C

l/min

13,7

13,7

-

-

-

-

Minimum capacity DHW flow rate

l/min

2,0

2,0

-

-

-

-

Maximum pressure on DHW circuit

bar

8

8

-

-

-

-

Flue tube

Ø mm

-

120

-

-

120

110

Coaxial flue system Ø 60/100 max length

m

5

-

5

5

-

-

Dual flue system Ø 80 max length

m

30

-

30

30

-

-

Maximum flue mass flow rate

kg/s

0,014

0,020

0,014

0,012

0,020

0,014

Minimum flue mass flow rate

kg/s

0,014

0,018

0,014

0,012

0,018

0,013

Maximum flue temperature

°C

146

110

149

115

110

99

Dimensions (h x w x d)

mm

Net weight

Kg

33

29

28

26

IPX5D

IPX5D

730x400x299

Gas type Grade of protection

24

Fanned flue

32

31

Natural gas/LPG IPX5D

IPX5D

IPX5D

IPX5D

*Heating only models are connectable to UB-UB INOX 80/120 lt. See page 26 for sanitary performance.


Gas boilers

Mainfour

Technical pages 49-57 65-68 70-72

• • • • • • •

75

76-77

Ultra compact dimensions (730x400x299 mm) Digital control panel with wide LCD display and push-buttons Bi-thermic rapid heat exchanger Anti-scale electronic system Full anti-frost device Connection to Baxi integrated solar systems option Outdoor sensor option

Digital control panel The new digital control panel with LCD display and push-buttons makes the boiler’s working check easy and immediate: clear and simple symbols allow to show all boiler’s parameters and anomalies that may occur. Combi

Steel burner Bi-thermic rapid heat exchanger made of copper pipes protected with anticorrosion coating Automatic by-pass System to prevent pump sticking operating every 24 hours Heating circuit relief valve set at 3 bar

Thermoregulation system Two heating temperatures possible ranges: 30/85°C, 30/45°C Built-in climatic regulation (outdoor sensor available as optional)

Control system Overheat limit thermostat for the water/flue exchanger Hydraulic pressure switch to prevent boiler’s operating in event of low water Pressure switch to ensure safe discharge of flue products (240F model) Flue thermostat to ensure safe discharge of flue products (24 model) Electronic temperatures control by NTC sensors Full anti-frost device Anti-scale electronic system Electronic thermometer Central heating pressure gauge

Openflue

Fanned flue

Hydraulic system Product code

Natural Gas LPG

240 F

24

BSE 46624365 46624165

BSB 46224365 46224165

Maximum heat input

kW

25,8

26,3

Minimum heat input

kW

10,6

10,6

Maximum heat output

kW

24

24

Minimum heat output

kW

9,3

9,3

Maximum efficiency

%

92,9

90,6

Energetic efficiency (92/42/CEE) Efficiency at 30% Minimum working temperature Expansion vessel capacity/pre-charge

%

★★★

★★

90,2

89,3

°C

-5

-5

l/bar

6/0,5

6/0,5

Heating system max pressure

bar

3

3

Regulation of water temperature in heating circuit

°C

30/85 30/45

30/85 30/45

Regulation of water temperature in DHW circuit

°C

35/55

35/55

DHW production ∆T 25°C

l/min

13,7

13,7

Minimum capacity DHW flow rate

l/min

2

2

Minimum pressure on DHW circuit

bar

0,15

0,15

bar

8

8

Ø mm

-

120 -

Maximum pressure on DHW circuit Flue tube Coaxial flue system Ø 60/100 max length

m

5

Dual flue system Ø 80 max length

m

30

-

Maximum flue mass flow rate

kg/s

0,016

0,021

Minimum flue mass flow rate

kg/s

0,016

0,018

Maximum flue temperature

°C

149

120

Dimensions (h x w x d)

mm

Net weight

kg

730x400x299 31

Gas type Power consumption Grade of protection

29 Natural gas/LPG

W

130

80

IPX5D

IPX5D

25


Slim

Technical pages 50-57 65-68 70-72

• • • • • • •

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Central heating timer option DHW timer option (DHW production models)

Slim is ideal for installation In compact spaces.

Heating only* Fanned flue 1.230FiN

76-77

Cast iron exchanger 60 litres stainless steel cylinder (2.300 Fi) 50 litres cylinder (2.230 i, 2.300 i) Multifunctional display Low energy circulating pump (Fi, i models) System to prevent pump sticking operating every 24 hours Connection to cylinder option for DHW production (heating only models)

Compact dimensions

1.230 Fi

75

1.300 Fi

With DHW storage Fanned flue

Open flue 1.300 FiN

1.150 i

1.230 i

1.300 i

1.230 iN

1.300 iN

1.400 iN

1.490 iN

1.620 iN

2.300 Fi

Open flue 2.230 i

2.300 i

43523301 43523347 43530301 43530347 43115301 43123301 43130301 43123347 43130347 43140347 43149347 43162347 43730301 43423301 43430301

Product code

WSB

Maximum heat input

kW

24,5

24,5

33

33

16,5

24,5

33

24,5

33

44,4

54,1

69

33

24,5

33

Minimum heat input

kW

13,5

13,5

17

17

9,5

13,5

17

13,5

17

23

27,5

35

17

13,5

17

Maximum heat output

kW

22,1

22,1

29,7

29,7

14,9

22,1

29,7

22,1

29,7

40

48,7

62,2

29,7

22,1

29,7

Minimum heat output

kW

11,8

11,8

14,9

14,9

8,5

11,8

14,9

11,8

14,9

20,6

24,5

31,6

14,9

11,8

14,9

Maximum efficiency

%

90

90

90,3

90,3

90,3

90,2

90

90,2

90

90,1

90

90,1

90,3

90,2

90

%

★★ 89,6

★★ 89,6

★★ 88,8

★★ 88,8

★★ 88,2

★★ 88,5

★★ 88,5

★★ 88,5

★★ 88,5

★★ 88,8

★★ 88,4

★★ 88,9

★★ 88,8

★★ 88,5

★★ 88,5

4

4

5

5

3

4

5

4

5

6

7

9

5

4

5

l

11,8

11,8

14,6

14,6

9

11,8

14,6

11,8

14,6

17,4

20,2

25,8

14,6

11,8

14,6

Expansion vessel/pre-charge

l/bar

10/1

-

10/1

-

10/1

10/1

10/1

-

-

-

-

-

10/1

10/1

10/1

Heating system max pressure

bar

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

Energetic efficiency (92/42/CEE) Energetic efficiency 30% Cast irons sections Cast irons boiler water capacity

Regulation of heating water temperature Cylinder temperature regulation

°C

30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/85 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45 30/45

°C

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

5/65

DHW production ∆T 35°C

l/min

-

-

-

-

-

-

-

-

-

-

-

-

12,2

9

12,1

DHW production at discharge ∆T 30°C

l/30’

-

-

-

-

-

-

-

-

-

-

-

-

485

366

475

Maximum pressure on DHW system

bar

-

-

-

-

-

-

-

-

-

-

-

-

8

8

8 140

Flue tube

Ø mm

-

-

-

-

110

130

140

130

140

160

160

180

-

130

Coaxial flue system Ø 60/100 max length

m

5

5

5

5

-

-

-

-

-

-

-

-

5

-

-

Dual flue system Ø 80 max length

m

20

20

20

20

-

-

-

-

-

-

-

-

20

-

-

mm

850 350 600

850 350 600

850 350 600

850 350 600

850 350 520

850 350 600

850 350 680

850 350 600

850 350 680

850 350 635

850 350 715

850 350 875

850 650 600

850 650 600

850 650 600

kg

121

111

144

134

89

113

136

103

126

150

174

224

184

155

176

Dimensions

Net weight

height width depth

Gas type Power consumption Grade of protection

Natural gas/LPG W

170

70

170

70

120

120

120

15

15

15

15

15

170

120

120

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

IPX4D

* Heating only models are connectable to Slim UB-UB INOX 80/120 lt. See page 31 for sanitary performance.

26


Gas floor standing boilers

Slim HP

Technical pages

50

75

• Body composed by pre-assembled cast iron elements properly designed to optimize the efficiency • Stainless steel two-stage atmospheric burner and gas valve • 50 mm fiberglass insulation • Flue safety thermostat

Control panel Very user friendly control panel which incorporates full safety features, including control and high limit thermostats, thermometer, and burner on/off switch.

Easy mounting of cast-iron elements Safe lightening by intermittent pilot ignition Weather compensated central (cascade installations) Connection to an indirect cylinder option Cascade installation option

Heating only Open flue 1.830 iN

1.990 iN

1.1160 iN

WSO

43108360

43109960

43111660

Power output Power output first stage 60% Power input Power input first stage 60%

kW kW kW kW

82.8 49.7 90 54

99.4 59.6 108 64.8

115.9 69.5 126 75.6

Nominal efficiency Number of elements Number of burners

%

92 6

92 7

92 8

5

6

7

35 5

40 5

44 5

202

202 0.5

252

9.5

11.4

13.3

Product code

Number of burner injectors Water content of the cast-iron body Maximum pressure in the heating circuit

bar

Flue (outside)

Ø Ø

Pilot burner injector G20 Natural gas 20 mbar

Propane gas 37 mbar

G20

Flow rate m³/h 15°C 1013 mbar Pressure at injectors

mbar

Injector mark Flue temperature CO2 Flue flow rate at design rate Pilot burner injector Injector mark Flow rate 15°C 1013 mbar G31 Pressure at injectors

Design rate (Qn) 60%

6

100%

16.5 °C % kg/h Ø

Design rate (Qn) mbar

134 6 235.4

7 60% 100%

320 W 148 7 243.2 0.3 215 Y 8.4

125 5 358.7

9.8

14.5 35

* with antirefouler These models are connectable to indirect cylinders. See pages 33-35.

27


Solar systems Collectors for forced draft installation

28

29


Solar systems Technical pages

58

Collectors for forced draft installation SB 25+V/O, SB 20+V/O, SB 100

• • • • • •

Gross surface: 2,51 m² (SB25+V/O), 2,01 m² (SB20+V/O ), 10,05 m2 (SB100) Meander pipes for a better heat transmission (SB20+,SB25+) Installation on a pitched, flat built in roof Solutions for groups from 3 to 7 people Hydraulic group with electronic regulation available as optional Connection to the range of cylinders from 200 to 3000 lt, single or double coil option

Product code Gross surface Absorber area Aperture area Collector capacity Maximum working pressure Maximum working temperature ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses

SVB 26

Collectors 4# 7 4# 0 61520430 61520330

LSC m² m² m² lt bar °C

4# 7 61525430

4# 0 61525330

%

W/m²k² W/m²k²

4#

61521430

4# 61501010

• Gross surface: 2,57 m2 • Absorption capacity 96% • Type of covering: vacuum tubes sidney type with boronsilicate glass and highly selective internal layer

Product code Gross surface Absorber area Aperture area Collector capacity Maximum working pressure ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses

Collector SVB26 61527010 2,57 2,36 2,23 2,27 10

LSC m² m² m² lt bar %

60,5

W/m²k² W/m²k²

0,85 0,01

* data based on an average temperature of the heat transfer fluid

Collectors for natural draft installation SB 21+

• • • •

Gross surface 2,01 m2 One collector (SB 21+) solution with 150 or 200 liters capacity cylinder Two collectors (SB 21+) solution with 300 liters capacity cylinder Installation on flat or pitched roof

Product code Collector Gross surface Absorber area Aperture area Collector capacity Cylinder capacity Maximum working pressure Maximum working temperature ŋo - Efficiency (with reference to the absorber surface)* α1 Heat losses α2 Heat losses

LSC

STS-150L 69000100 1

m² m² m² lt l bar °C

150

Collector STS-200L 69000101 1 2,01 1,88 1,89 1,52 200 10 200

%

76,1

W/m²k² W/m²k²

4,33 0,009

STS- 300L 69000102 (flat roof) 69000103 (pitched roof) 2

300

29


Indirect cylinders Indirect cylinders - UB - UB inox - Slim - Slim UB inox - Combi 80 lt - Indirect cylinders

30

31 31 32 33


Indirect cylinders

UB - UB inox

Technical pages

59

78

• 80/120 lt indirect cylinder available in stainless steel AISI 316L or coated steel • Magnesium anode for anticorrosion protection • Nipples in the fixing template • Indirect cylinder temperature controlled directly on the boiler’s control panel

UB Product code 80 Product code 120

Condensig boilers KSG 71403171 KSG 71403181

Cylinder Capacity

Gas boilers

12 kW WH boiler 24 kW WH boiler 28 kW WH boiler 25 kW WH boiler 24 kW WH boiler 31 kW WH boiler 18 kW WH boiler 14 kW WH boiler + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120

l

80/120

80/120

80/120

80/120

80/120

80/120

80/120

DHW production ∆T 25°C in continuous

l/min

6,9

13,8

16,1

14,3

13,7

18

10

8

DHW production ∆T 30°C at discharge

l/30 min

270/330

430/480

480/530

440/490

430/480

490/540

340/390

290/350

bar

8

8

8

8

8

8

8

8

Maximum pressure DHW system UB INOX Product code 80 INOX Product code 120 INOX

Condensig boilers KSG 71408441 KSG 71408451

Cylinder Capacity

80/120

Gas boilers

12 kW WH boiler 24 kW WH boiler 28 kW WH boiler 25 kW WH boiler 24 kW WH boiler 31 kW WH boiler 18 kW WH boiler 14 kW WH boiler + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120 + UB 80/120

l

80/120

80/120

80/120

80/120

80/120

80/120

80/120

DHW production ∆T 25°C in continuous

l/min

6,9

13,8

16,1

14,3

13,7

18

10

8

DHW production ∆T 30°C at discharge

l/30 min

270/330

430/480

480/530

440/490

430/480

520/570

340/390

290/350

bar

8

8

8

8

8

8

8

8

Maximum pressure DHW system

80/120

Slim UB - Slim UB inox • 80/120 lt indirect cylinder available in stainless steel AISI 316L or coated steel • Magnesium anode for anticorrosion protection • Nipples in the fixing template • Indirect cylinder temperature controlled directly on the boiler’s control panel

SLIM UB Product code 80 Product code 120

Gas boilers KSW 71412241 KSW 71412251

Cylinder Capacity

14,9 kW FS boiler + UB 80/120

22,1 kW FS boiler + UB 80/120

29,7 kW FS boiler + UB 80/120

40 kW FS boiler + UB 80/120

48,7 kW FS boiler + UB 80/120

62,2 kW FS boiler + UB 80/120

80/120

l

80/120

80/120

80/120

80/120

80/120

DHW production ∆T 25°C in continuous

l/min

8,5

12,7

17

19,5

19,5

19,5

DHW production ∆T 30°C at discharge

l/30 min

300/360

400/450

490/550

490/610

490/610

490/610

bar

8

8

8

8

8

8

14,9 kW FS boiler + UB 80/120

22,1 kW FS boiler + UB 80/120

29,7 kW FS boiler + UB 80/120

40 kW FS boiler + UB 80/120

48,7 kW FS boiler + UB 80/120

62,2 kW FS boiler + UB 80/120

80/120

Maximum pressure DHW system

SLIM UB INOX Product code 80 INOX Product code 120 INOX

Gas boilers KSW 71408781 KSW 71408791

Cylinder Capacity

l

80/120

80/120

80/120

80/120

80/120

DHW production ∆T 25°C in continuous

l/min

8,5

12,7

17

19,5

19,5

19,5

DHW production ∆T 30°C at discharge

l/30 min

300/360

400/450

500/550

570/620

570/620

570/620

bar

8

8

8

8

8

8

Maximum pressure DHW system

31


Combi 80 lt

Technical pages 45-57 65-68 70-72 76-77

• 80 lt stainless steel AISI 316L indirect cylinder • Magnesium anode for anticorrosion protection • Easy connection to heating only wall hung boilers for a free standing installation

Product code KSL 71408471

Luna3 Comfort + Combi

+

=

1.240 Fi - 1.310 Fi - 1.240 i models

Luna3 Comfort 1.240 Fi Stainless steel cylinder capacity

1.310 Fi

1.240 i

l

80

80

80

°C

35/60

35/60

35/60

DHW production ∆T 25°C in continuous

l/min

14,3

18

13,7

DHW production ∆T 30°C at discharge

l/30 min

420

520

420

Maximum recovering time of the cylinder

min

8

3

8

Maximum pressure DHW system

bar

8

8

8

Cylinder DHW temperature regulation

32


Indirect cylinders

Indirect cylinders

Technical pages 59-60

• Enamelled steel indirect cylinders • DHW sensor for indirect cylinder available as option • It is necessary to install the optional 3 way valve motor (KHG 714106610 ) for connection to Luna3 and Luna3 Comfort models. • It is necessary to use specific kit (KHG 714096311 ) with electric 3 way valve for connection to Ecofour, Fourtech

.

.

DHW indirect cylinders

UB 200 SC/DC Product code

SC DC

LSC

Cylinder capacity

71520701 71520801

lt

200

Insulation Coil

UB 200 SC/DC

polyurethane SC DC

single double

Insulation thickness

mm

50

Working maximum pressure

bar

8

Working maximum pressure in the coil

bar

8

Upper coil thermal exchange (DC)

kW

20

Lower coil thermal exchange (SC/DC)

kW

27

Weight

kg kg

95 107

mm

1275x600

SC DC

Dimensions HxØ

DHW indirect cylinders with wider exchange surface

Product code

SC+ DC+

Cylinder capacity

UB 300 SC+/DC +*

UB 400 SC+/DC +*

71003701 71003801

71004701 71004801

LSC lt

Insulation Coil

400 polyurethane

single double

single double

SC DC

Insulation thickness

mm

50

50

Working maximum pressure

bar

10

10

Working maximum pressure in the coil

bar

10

10

Upper coil thermal exchange (DC)

kW

30

30

Lower coil thermal exchange (SC/DC)

kW

45

55

Weight

kg kg

118 135

144 161

mm

1797x600

1780x700

SC DC

Dimensions HxØ

UB 300 SC+/DC+

300 injection polyurethane

UB 400 SC+/DC+

Stainless steel cylinders for DHW production

Product code Cylinder capacity

UBSS 250 DC

UBSS 260 SC

LSC

71525801

71525701

lt

250

260

polyurethane foam

polyurethane foam

double

single

Insulation Coil Insulation thickness

mm

45

45

Working maximum pressure

bar

10

10

Working maximum pressure in the coil

bar

10

10

Upper coil thermal exchange (DC)

kW

20

-

Lower coil thermal exchange (SC/DC)

kW

27,8

27,8

Weight

kg

58

48

Dimensions HxØ

mm

1743x545

1804x545

UBSS SC/DC 33


Technical pages 59-60

Cylinders for DHW production for solar integration

UB 200 SOLAR Product code Cylinder capacity

KSL lt

Coil

71413521 200 single

Working maximum pressure

bar

8

Working maximum pressure in the coil

bar

6

Coil thermal exchange (∆T=30° C)

kW

20

Weight

kg

145

Dimensions (h x w x d)

mm

1500x600x640

LSC

71003821

UB 200 SOLAR

• • • • • •

Vitrified steel DHW cylinder with single coil exchanger for solar integration To be connected to any combi boiler Mixing valve and diverter valve supplied with the cylinder Solar circulating group supplied with the cylinder DHW expansion vessel – 8 lt capacity – supplied with the cylinder Solar expansion vessel – 18 lt capacity – supplied with the cylinder

Cylinders for DHW production with solar circulating group

UBSI 300 Product code Cylinder capacity

lt

Insulation Coil

• cylinder • hydraulic group • expansion vessel

UBSI 300

34

300 injection polyurethane double

Insulation thickness

mm

55

Working maximum pressure

bar

10

Working maximum pressure in the coil

bar

10

Upper coil thermal exchange

kW

18,5

Lower coil thermal exchange

kW

37,5

Weight

kg

135

Dimensions HxØ

mm

1706x610


Indirect cylinders Enamelled steel cylinders for DHW production

UB 500 DC

UB 800 DC

Product code

SC DC

UB 1000 SC/DC

lt

Insulation SC DC

Insulation thickness

UB 800 DC

71005801 500

UB 2000 SC/DC

mm

UB 3000 SC UB 1500 DC

71008801

UB 1000 SC/DC 71010701 71010801

800

1000

injection polyurethane

polyurethane stiff bowls

soft polyurethane

double

double

single double

50

85

LSC

Cylinder capacity

Coil

UB 1500 DC

UB 500 DC

Technical pages 59-60

UB 3000 SC 71030701

71015801

UB 2000 SC/DC 71020701 71020801

1500

2000

3000

soft polyurethane

soft polyurethane

soft polyurethane

double

single double

double

100 (SC) 85 (DC)

100

100

100

Working maximum pressure

bar

10

10

10

10

10

10

Working maximum pressure in the coil

bar

10

10

10

10

10

10

Upper coil thermal exchange (DC)

kW

30

37

45 60 (DC)

63

74

-

Lower coil thermal exchange (SC/DC)

kW

60

60

63 (SC)

107

115

134

Weight

kg kg

174

235

206 243

386

465 465

670

mm

1780x760

1905x990

2285x1200

2550x1300

2980x1400

SC DC

Dimensions HxØ

2120x940 (SC) 2155x990 (DC)

Cylinders for DHW production and integration with solar systems on the heating circuit

UBTT 1000

Product code Cylinder capacity

UBPT 1000

LSC DHW Heating

Insulation Cylinder Coil

UBPT 2000

UBPU 1500 SC

UBTT 1000

UBPT 1000

UBPT 2000

UBPU 1500

71010501

71010601

71020601

71015302

220 780

1000

2000

1500

soft polyurethane

soft polyurethane

soft polyurethane

soft polyurethane

tank in tank

pipe in tank

pipe in tank

buffer

single (SC)

double (DC)

double (DC)

single (SC) 100

Insulation thickness

mm

100

120

120

Working maximum pressure

bar

3

3

3

3

Working maximum pressure in the coil

bar

10

10

10

10

Upper coil thermal exchange

kW

n.a.

97

135

n.a.

Lower coil thermal exchange

kW

69

97

177

89

Weight

kg

245

210

325

230

Dimensions HxØ

mm

2090x990

2110x1030

2380x1340

2150x1300

35


Waters heaters

36

Electric waters heaters

37

Gas storage waters heaters

37


Water heaters

Electric water heaters • • • • • • • Product code Capacity Installation Rating/voltage Adjustable thermostat Height Width Depth

Product code Capacity Installation Connection Rating/voltage Adjustable thermostat Thermometer Height Width Depth

Product code Capacity Installation Connection Rating/voltage Adjustable thermostat Thermometer Height Width Depth

RSA l W/V mm mm mm

ASA l

W/V

mm mm mm

ASA l

W/V

mm mm mm

SR 501 31501811 10 above sink 1.200/230 internal 432 267 250 SV 530 31503811 30 upright 1.200/230 internal 542 340 SV 510 TD 31510715 100 upright right 1.500/230 internal • 920 440

Technical pages 61-62

77

Polystyrene insulation (10-15 lt) Polyurethane insulation (30-100 lt) 40% energy saving Steel water tank coated with titanium enamel vitrified at 900°C Magnesium anode RoHS-WEEE Compliant Grade of protection: IPX4

SR 501 CR 31501252 10 above sink 1.200/230 external 432 267 250 SV 530 R 31503252 30 upright 1.200/230 external 542 340 SV 510 TS 31510716 100 upright left 1.500/230 internal • 920 440

SR 501 SL 31501821 10 under sink 1.200/230 internal 432 267 250

SV 550 31505215 50 upright 1.200/230 internal • 520 440

SR 501 CR SL 31501262 10 under sink 1.200/230 external 432 267 250

SV 580 31508215 80 upright 1.200/230 internal • 760 440

SO 580 31508217 80 horizontal 1.200/230 internal • 760 440

SV 510 31510215 100 upright 1.500/230 internal • 920 440

SO 510 31510217 100 horizontal 1.500/230 internal • 920 440

SR 515 31502811 15 above sink 1.200/230 internal 432 350 310 SV 550 TD 31505715 50 upright right 1.200/230 internal • 520 440

SO 580 TD 31508714 80 horizontal right 1.200/230 internal • 760 440

SR 515 CR 31502252 15 above sink 1.200/230 external 432 350 310

SV 550 TS 31505716 50 upright left 1.200/230 internal • 520 440

SO 580 TS 31508718 80 horizontal left 1.200/230 internal • 760 440

SV 580 TD 31508715 80 upright right 1.200/230 internal • 760 440 SO 510 TD 31510714 100 horizontal right 1.500/230 internal • 920 440

SR 515 SL 31502821 15 under sink 1.200/230 internal 432 350 310 SV 580 TS 31508716 80 upright left 1.200/230 internal • 760 440 SO 510 TS 31510718 100 horizontal left 1.500/230 internal • 920 440

Gas storage water heaters • Porcelain enamel vitrified steel boiler to ensure long-lasting product • Adjustable thermostat • Magnesium anode • Wall hung or floor standing installation

WALL HUNG Product code Capacity

ASB lt

FLOOR STANDING

SAG2 50

SAG2 80

SAG2 100

SAG2 125 T

SAG2 155 T

SAG2 195 T

SAG2 300 T

311053130 • 50

311083130 • 80

311103130 • 100

311123140 • 125

311153140 • 155

311193140 • 195

311303140 • 300 17,4

Maximum heat input

kW

4,2

5,8

5.8

7,5

8,5

9

Maximum heat output

kW

3,49

4,82

4,82

6,3

7,2

7,8

14,6

DHW temperature regulation

°C

40-70

40-70

40-70

40-70

40-70

40-70

40-70

l/min

1,7

2,3

2,3

3,0

3,4

3,7

6,9

Nat. Gas/LPG

Nat. Gas/LPG

Nat. Gas/LPG

Nat. Gas/LPG

Nat. Gas/LPG

Nat. Gas/LPG

Nat. Gas/LPG

DHW flow rate ∆T 30°C Thermostat Gas type Thermometer

-

-

-

-

Height

mm

613

863

983

1250

1420

1730

1700

Diameter

mm

450

450

450

520

520

520

600

37


Technical Section

38

Technical drawings Graphs Flue systems

39

Flue pipe accessories

63

Hydraulic accessories

70

Thermoregulation accessories

73

Other accessories

77

Products technical data

79


Technical drawings Graphs Flue systems Condensing gas boilers Gas boilers Flue systems Solar collectors Indirect cylinders Electric water heaters Gas water heaters

40 44 51 58 59 61 62

39


Condensing gas boilers Luna Platinum

HEAD mH2O

177

A69

Luna Platinum 24, 33, 1.12, 1.18, 1.24, 1.32

B 686

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections

max min

FLOW RATE (l/h)

50 45 179 A69

HEAD mH2O

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections

Luna Duo-tec 177

FLOW RATE (l/h)

50 45 179

40

max min

B 686

Luna Duo-tec 24, 28, 33, 40, 1.12, 1.24, 1.28


Technical drawings - graphs - flue systems

Condensing gas boilers Duo-tec Compact 24, 1.24

Duo-tec Compact

400 238

FLOW RATE (l/h)

70

40 30

105 162

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections

B 686

A69

299

Duo-tec Max

Duo-tec Max 24, 33 A69

HEAD mH2O

177

max min

B 686

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage; tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” SC Condensing trap possible to connect on a pipe Ø 21 A Boiler hanging points. Distance between hanging points: 298 mm B Distance between hanging points and hydraulic connections

HEAD mH2O

124

FLOW RATE (l/h)

50 45 179

41


Condensing gas boilers Nuvola Platinum

Nuvola Platinum 24, 33

181

HEAD mH2O

1 2 3 4 5 SC

156,5

DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4” Condensing trap possible to connect on a pipe Ø21

MAX MIN

FLOW RATE (l/h)

117,5

100

110

100

110

62,5

SC

bottom view

Nuvola Duo-tec

Nuvola Duo-tec 16, 24

181

HEAD mH2O

1 2 3 4 5 SC

156,5

DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4” Condensing trap possible to connect on a pipe Ø21

FLOW RATE (l/h)

117,5

100

110

100

110

SC

bottom view

42

max min

62,5


Technical drawings - graphs - flue systems

Condensing gas boilers Luna3 Comfort HT Solar - heating system circuit

600

HEAD mH2O

Luna3 Comfort HT Solar 120, 120 MS, 240, 240 MS 640 600

433,5

273

273

415

I speed.

H

89

I L

III speed. II speed.

760 832

190 65105

FLOW RATE (l/h)

103

95 130 130 E F G

2056

A B C D

Luna3 Comfort HT Solar

9085 95 90

HEAD mH2O

95

frontal view

A B C D E

side view

I speed.

back view

F G H I L

DHW relief valve outlet G 1/2” Mains water G 1/2” DHW recirculation G 1/2” DHW outlet G 1/2” Heating system flow G 3/4”

Gas supply pipe G 3/4” Heating system return G 3/4” Solar relief valve outlet G 1/2” Collector inlet G 3/4” Collector outlet G 3/4”

III speed. II speed.

FLOW RATE - Solar circuit

Hybrid Systems Prevalenza

HEAD mH2O

Luna Platinum CSI 33

70 70

70 70 70 70

frontal view

72

856

672

back view

side view

Prevalenza

850

65

Portata FLOW RATE Q (l/h)

Example : pump head 2nd zone with half-open mixing valve

HEAD mH2O

65

1

HEAD mH2O

65

2

2

Portata FLOW RATE Q (l/h)

65

1

Prevalenza

868

Prevalenza

80 80 80 80 80 80 80 80 80 80 80 80 80

70 70

152

2060

70 70

HEAD mH2O

Portata FLOW RATE Q (l/h)

Zonazone 1 portata 0 rate 0 III 1st flow Zonazone 1 portata 500 l/h 500 l/h II 1st flow rate Zonazone 1 portata 1000 l/h 1000 l/h I 1st flow rate

Portata FLOW RATE Q (l/h)

43


Gas boilers Luna3 Comfort 240 i, 1.240 i

Luna3 Comfort 310 Fi - 1.310 Fi

HEAD mH2O

Luna3 Comfort 240 Fi, 310 Fi, 1.240 Fi, 1.310 Fi

FLOW RATE (l/h)

HEAD mH2O

Luna3 Comfort 240 i - 1.240 i - 1.240 Fi - 240 Fi

FLOW RATE (l/h)

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 425 mm B Distance between hanging points and hydraulic connection

Luna3 240 i

188 100

Luna3 310 Fi - 1.310 Fi - 280 Fi - 240 Fi - 240 i

HEAD mH2O

Luna3 240 Fi, 280 Fi, 310 Fi, 1.310 Fi

FLOW RATE (l/h)

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4” A Boiler hanging points. Distance between hanging points: 425 mm B Distance between hanging points and hydraulic connection

44


Technical drawings - graphs - flue systems

Gas boilers Luna3 Comfort Air 250 Fi, 310 Fi HEAD mH2O

Luna3 Comfort Air 250 Fi - 310 Fi

FLOW RATE (l/h)

MR US GAS ES RR A

B

Heating system flow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4” Boiler hanging points. Distance between hanging points: 425 mm Distance between hanging points and hydraulic connection

Luna3 Comfort + Combi 240 Fi, 310 Fi HEAD mH2O

Luna3 Comfort + Combi 240 Fi - 310 Fi

FLOW RATE (l/h)

frontal view

A B C E F G I

side view

back view

view from above

Heating system flow G 3/4” M Heating system return G 3/4” M Gas supply pipe G 3/4” M Mains water G 1/2” M DHW outlet G 1/2” M DHW recirculation G 1/2” M Relief valve outlet

45


Gas boilers Luna3 Blue 180 i - 1.180 i - 240 i

Luna3 Blue 180 i, 240 i, 1.180 i

188 100

C

HEAD mH2O

Luna3 Blue 240 Fi, 280 Fi, 1.240 Fi

III speed. II speed. FLOW RATE (l/h)

HEAD mH2O

Luna3 Blue 240 Fi - 1.240 Fi

III speed. II speed. FLOW RATE (l/h)

MR Heating system flow G 3/4” US DHW outlet G 1/2” (for heating only models storage tank flow G 3/4”) GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”

A

B C

Boiler hanging points. Distance between hanging points: 425 mm Distance between hanging points and hydraulic connection Ø 110: 180 i – 1.180 i Ø 130: 240 i

HEAD mH2O

Luna3 Blue 280 Fi

I speed. FLOW RATE (l/h)

Luna3 Comfort Max 240 i

Luna3 Comfort Max 310 Fi

HEAD mH2O

Luna3 Comfort Max 250 Fi, 310 Fi

III speed. II speed.

I speed.

III speed. II speed.

FLOW RATE (l/h)

HEAD mH2O

Luna3 Comfort Max 240 i - 250 Fi

II speed. FLOW RATE (l/h)

MR US GAS ES RR

46

Heating system flow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

A

B

Boiler hanging points. Distance between hanging points: 425 mm Distance between hanging points and hydraulic connection

III speed.


Technical drawings - graphs - flue systems

Gas boilers Nuvola3 Comfort 240 i, 280 i

Nuvola3 Comfort 140 Fi - 240 Fi/i

HEAD mH2O

Nuvola3 Comfort 140 Fi, 240 Fi, 280 Fi, 320 Fi

Ø100

FLOW RATE (l/h)

HEAD mH2O

Nuvola3 Comfort 280 Fi/i - 320 Fi

FLOW RATE (l/h)

1 2 3 4 5

DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Heating system flow G 3/4” Gas inlet G 3/4”

bottom view

Nuvola3 BS 240 i, 280 i

Nuvola3 BS 140/240

HEAD mH2O

Nuvola3 BS 140 Fi, 240 Fi, 280 Fi

Ø100

FLOW RATE (l/h)

Nuvola3 BS 280

6

HEAD mH2O

5 4 3 2 1 0

FLOW RATE (l/h)

1 2 3 4 5

Heating system flow G 3/4” DHW outlet G 1/2” Mains water G 1/2” Heating system return G 3/4” Gas inlet G 3/4”

bottom view

47


Gas boilers Luna3 Silver Space 250 Fi, 310 Fi HEAD mH2O

Luna3 Silver Space 250 Fi - 310 Fi

MR US GAS ES RR A

B

FLOW RATE (l/h)

Heating system flow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4” Boiler hanging points. Distance between hanging points: 524 mm Distance between hanging points and hydraulic connection

Ecofour 24 F, 1.14 F, 1.24 F

Ecofour 24, 1.14, 1.24

EcoFour

HEAD mH2O

400 400

162 122

Ø120 (24 kW) Ø110 (14 kW)

FLOW RATE (l/h)

B 680

B 680

730

730

A 23

A 23

Ø100

70

70 65 65 65 65

70

9 14 5,5 2,5

MR US GAS ES RR

48

1

Heating system fl ow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

A

B

65 65

70 65 65

95 ,5

Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection


Technical drawings - graphs - flue systems

Fourtech 24 F, 1.14 F, 1.24 F

Fourtech 24, 1.14, 1.24 400

Fourtech

400

Ø120 (24 kW) Ø110 (14 kW)

A 23

A 23

Ø100

HEAD mH2O

162 122

B 680

B 680

730

730

FLOW RATE (l/h)

70

65 65 65

70 65

70

65

70 65

9 14 5,5 2,5

9 1 4 5, 5 2,5

Heating system fl ow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

A

B

Mainfour 240 F

Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection

Mainfour 24 400

400

MainFour 24 162

122

Ø100 A 23

A 23

Ø120

HEAD mH2O

MR US GAS ES RR

65 65

70

70 65 65 65 65

70

9 14 5,5 2,5

MR US GAS ES RR

MainFour 240F

65 65

70 65 65

9 14 5,5 2,5

Heating system fl ow G 3/4” DHW outlet G 1/2” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

A

B

HEAD mH2O

B 680

B 680

730

730

FLOW RATE (l/h)

FLOW RATE (l/h)

Boiler hanging points. Distance between hanging points: 343 mm Distance between hanging points and hydraulic connection

49


Gas boilers Slim 1.230 Fi, 1.300 Fi

HEAD mH2O

542 - 622 520 - 600

116 119 115

520 - 600

350

Slim 2.300 Fi - 2.230 i - 2.300 i - 1.150 i 1.230 i - 1.300 i - 1.230 Fi - 1.300 Fi

Slim 1.230 FiN, 1.300 FiN

A

A 850

I speed.

C

C

0

III speed.

II speed.

0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4

FLOW RATE (l/h) B 481 - 564 596 - 676

frontal view

481 - 561 507 - 587

B

side view

back view

Slim 1.150 i, 1.230 i, 1.300 i

side view

Slim 1.230 iN, 1.300 iN

back view

Slim 1.400 iN, 1.490 iN, 1.620 iN

A Heating system flow G 3/4” M B Heating system return G 3/4” M C Gas supply pipe G 1/2” M

L1 Slim 1.150i Slim 1.230i, 1.230iN Slim 1.300i, 1.300iN

520 600 680

dimensions (mm) L1

Slim 1.400iN Slim 1.490iN Slim 1.620iN

H

L2

1490 1490 1650

635 715 875

dimensions (mm) L2

frontal view

side view

frontal view

Slim 2.300 Fi

side view

back view

Slim 2.230 i, 2.300 i

A B C D E F back view

back view

side view

Heating system flow G 3/4” M Heating system return G 3/4” M Gas supply pipe G 1/2” M Mains water G 1/2” M DHW outlet G 1/2” M Recirculation G 1/2” M (Slim 2.260 Fi) Recirculation G 1/2” F (Slim 2.230 i, 2.300 Fi)

frontal view

Slim HP 1.830 iN, 1.990 iN, 1.1160 iN 1190 B

Number of elements

6

7

8

C 910 Flow outlet 51

45

Ø E

A

mm

537

612

699

B

mm

1100

1100

1160

C

mm

975

975

1000

D

mm

1003

1003

1013

E (outside)

Ø

202

202

252

Blackflow

Ø

Rp 1” ½

Outlet -inlet of gas

Ø

Rp 1” ½

263

Gas inlet

D 874

874

1004

ΔP to Δt 15 Water content Weight

A

143

243

Back outlet

Bleed tap Ø 1/2

485 60

50

807

mbar

31

41

l

35

40

53 44

Kg

330

375

415


Technical drawings - graphs - flue systems

Coaxial flue system ■ Ø 60/100 mm ■ Ø 80/125 mm

Luna Platinum, Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Platinum, Nuvola Duo-tec, Luna3 Comfort HT Solar

- NBY N N

- NBY N N

- NBY N N

- NBY N N - NBY N N

- NBY N N

- NBY N N

- NBY N N

- NBY N N

- NBY N N -"4 DIJNOFZ

Tubes maximum length (m) Ø 60/100

Ø 80/125

10

25

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

1

0,5

Duo-tec Compact

Luna Platinum - Luna Duo-tec Duo-tec Max

NJO

NJO

GSPOUBM WJFX

TJEF WJFX

GSPOUBM WJFX

Nuvola Platinum - Nuvola Duo-tec

Luna3 Comfort HT Solar

NJO

TJEF WJFX

TJEF WJFX

GSPOUBM WJFX

GSPOUBM WJFX

TJEF WJFX

51


Coaxial flue system Luna3 Comfort - Luna3 Comfort + Combi - Luna3 - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max - Luna3 Silver Space - Ecofour - Fourtech - Mainfour - NBY

- NBY

- NBY

- NBY

- NBY - NBY

-"4 DIJNOFZ

- NBY

- NBY

- NBY

- NBY

Lmax can change according to the flue type and boiler models. See the instruction manual.

Horizontal flue

Ø 60/100

Ø 80/125

5 4 4 5 4 4 4

9 8 10 -

Luna3 24/25 kW Luna3 28/31 kW Luna3 Blue Ecofour - Fourtech - Mainfour Luna3 Luna3 Blue Ecofour - Fourtech - Mainfour

Vertical chimney

Luna3 Comfort - Luna3 Comfort Air Luna3 Blue - Luna3 Comfort Max - Eco3

GSPOUBM WJFX

GSPOUBM WJFX

TJEF WJFX

GSPOUBM WJFX

TJEF WJFX

0,5

Luna3 Silver Space

TJEF WJFX

Ecofour - Fourtech - Mainfour

52

Luna3 Comfort + Combi

Length reduction for a 45° bend insertion (m)

1

NJO

NJO

Length reduction for a 90° bend insertion (m)

NJO

Tubes maximum length (m)

GSPOUBM WJFX

TJEF WJFX


Technical drawings - graphs - flue systems

â– Ă˜ 60/100 mm â– Ă˜ 80/125 mm

Nuvola3 Comfort - Nuvola3 BS

- NBY N N

- NBY N N

- NBY N N

- NBY N N - NBY N 'J

- NBY N N

- NBY N N - NBY N 'J

- NBY N 'J

-"4 DIJNOFZ

- NBY N 'J

- NBY N N

- NBY N N

- NBY N N

- NBY N N

Tubes maximum length (m)

Ă˜ 60/100

NJO

Horizontal

24/28 kW

4

8

14 kW

5

8

32 kW

3

8

4

10

flue

Vertical chimney GSPOUBM WJFX

Ă˜ 80/125

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

1

0,5

TJEF WJFX

Slim - NBY N

- NBY N

- NBY N

-"4 DIJNOFZ - NBY N

- NBY N

- NBY N

- NBY N

- NBY N - NBY N - NBY N

- NBY N

Slim 1.230 Fi/FiN, 1.300 Fi/FiN

Slim 2.300 Fi

BCPWF WJFX

Tubes maximum length (m)

NJO

NJO NJO

NJO

5 TJEF WJFX

BCPWF WJFX

Length Length reduction reduction for a 45° for a 90° bend insertion bend insertion (m) (m) 1

0,5

Ă˜ flue mm

60 - 100

TJEF WJFX

53


Dual flue system Luna Platinum, Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Platinum, Nuvola Duo-tec, Luna3 Comfort HT Solar

-

-

L1 = FLUE PIPE / L2 = INTAKE PIPE

- - NBY N - NBY N

Tubes maximum length (m)

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

Installation with terminal Ă˜ 60

30

3

1,25

Installation with terminal Ă˜ 80

80

0,5

0,25

Installation with chimney terminal

15

0,5

0,25

with adjustable dual flue kit

Luna Platinum - Luna Duo-tec Duo-tec Max

GSPOUBM WJFX

TJEF WJFX

Nuvola Platinum - Nuvola Duo-tec

GSPOUBM WJFX

TJEF WJFX

with adjustable dual flue kit

GSPOUBM WJFX

TJEF WJFX

GSPOUBM WJFX

Duo-tec Compact

TJEF WJFX

Luna3 Comfort HT Solar

NJO

54

GSPOUBM WJFX

TJEF WJFX

GSPOUBM WJFX

TJEF WJFX


Technical drawings - graphs - flue systems

Flexible ducting systems gas condensing boilers

,)(

,)(

,)(

,)( N

,)( N

,)(

,)(

,)( N

,)(

,)( N

,)(

,)( ,)(

,)(

,)(

,)(

ESBJO DPOEFOTBUF

,)(

,)(

,)(

Chimney terminal for a gas condensing boilers

ø ø

ø 1150

ø

484

25

,)( 3FEVDUJPO LJU GSPN ø UP ø

5

ø

Ø 80 Ø 125

,)( $PBYJBM WFSUJDBM DIJNOFZ UFSNJOBM ø

ø

,)( %VBM ðVF UVCFT BEBQUFS GPS DPBYJBM DIJNOFZ GSPN ø UP ø

55


Dual flue system Luna3 Comfort - Luna3 - Luna3 Comfort + Combi - Luna3 Comfort Air - Luna3 Blue - Luna3 Comfort Max Luna3 Silver Space - Ecofour - Fourtech - Mainfour -

-

-

Luna3 Comfort Luna3 Ecofour Blue Fourtech Mainfour 25 kW 31 kW 40

25

20

30

30 (G20) - 25 (G31)

25

L2 MAX m

10

10

10

10

10

10

-

-

-

-

25

22

25 kW

31 kW

10

8

L MAX m

Luna3 Blue

Ecofour Fourtech Mainfour

10

10

(L1+L2) MAX m

*B22

Luna3 Comfort

Luna3 Silver Space* 25 kW 31 kW

-

-

Luna3 Comfort

L MAX m

25 kW

31 kW

15

12

Luna3 Blue

Ecofour Fourtech

Mainfour

10

15

12

Luna3 Comfort 25 kW

31 kW

14

10

L MAX m

Luna3 Blue

Ecofour Fourtech

Mainfour

9

14

11

If the pipe length is longer than 6 meters the condensation storage kit must be installed. Tube maximum length (m)

Length reduction for a 90° bend insertion (m)

Installation with terminal Ø 80

80

0,5

0,25

Installation with chimney terminal

15

0,5

0,25

GSPOUBM WJFX

GSPOUBM WJFX

TJEF WJFX

Ecofour - Fourtech - Mainfour 97

130

97

97

130

400

GSPOUBM WJFX

56

GSPOUBM WJFX

GSPOUBM WJFX

TJEF WJFX

Luna3 Silver Space 122

97

=

Front view

= 400

GSPOUBM WJFX

299

TJEF WJFX

NJO

120

145

145

120

=

=

GSPOUBM WJFX

GSPOUBM WJFX

NJO

NJO

NJO

NJO

Luna3 Comfort + Combi

NJO

Luna3 Comfort - Luna3 - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max

Length reduction for a 45° bend insertion (m)

TJEF WJFX


Technical drawings - graphs - flue systems

Nuvola3 Comfort - Nuvola3 BS - -

-

-

-

M - NBY N N 'J

- NBY N N NPE $PNGPSU

- NBY N

- NBY N

NJO

Length reduction for a 90° Length reduction for a 45° bend insertion (m) bend insertion (m)

GSPOUBM WJFX

Ø Flue (mm)

Installation with proof terminal

0,5

0,25

80

Installation with chimney terminal

0,5

0,25

133

TJEF WJFX

-

-

-

- NBY N

-

Slim

- NBY N

FLUE PIPE (L1) MAXIMUM LENGTH WITH A 90° BEND: 10 m. INTAKE PIPE (L2) MAXIMUM LENGTH WITH A 90° BEND: 10 m. Length reduction for a 45° bend insertion (m)

Ø Flue (mm)

20

0,5

0,25

80

6

0,5

0,25

Slim 1.230 Fi/FiN, 1.300 Fi/FiN

133

Slim 2.300 Fi

NJO

Installation with chimney terminal

Length reduction for a 90° bend insertion (m)

NJO

Installation with proof terminal

Tubes maximum length (m)

BCPWF WJFX

BCPWF WJFX

525

998

467

Chimney terminal for gas boilers

Ø 100

,)( %VBM ðVF IPSJ[POUBM DIJNOFZ UFSNJOBM ø

Ø 60

,)( 7FSUJDBM DIJNOFZ UFSNJOBM GPS DPBYJBM ðVF TZTUFN ø

,)( %VBM ðVF WFSUJDBM DIJNOFZ UFSNJOBM ø

57


Collectors for forced natural draft installation SB 25 + V SB 25 + O

.*7

SB 20 + V SB 20 + O

.*6

@03)M

.*5 .*4

@03)S

.*3 .*2 .*1 .*0 .*/ .

I

(*)

I

(*)

.*7 .*6 .*5 .*4 @0.)S

.*3

h x w x d (mm)

.*2

SB 25 + V SB 25 + O SB 20 + V SB 20 + O SB 21 +

2187 1147 1755 1148

1147 2187 1148 1755

87 87 87 87

@0.)M

.*1 .*0 .*/ .

SB 100

SB 100

h x w x d (mm) SB 100

2064

4896

114

SVB 26

I

(*)

I

(*)

SVB 26

h x w x d (mm) SVB 26

1560

1647

107

SB 21+

SB 21+ .*7 .*6 .*5 .*4 .*3 .*2 .*1 .*0 .*/

h x w x d (mm) SB 21+

1753

1147

.

87

.,.

.,./ .,.0 .,.1 .,.2 .,.3 .,.4 .,.5 .,.6 .,.7 .,/.

I

58

(*) I = total incidental radiation on the collector surface (W/m2) tm = average temperature of the absorbing surface (째C) ta = room temperature (째C)

(*)


Technical drawings - graphs - flue systems

Indirect cylinders LUNA UB INOX LUNA UB 80, 120

SLIM UB INOX SLIM UB 80, 120

A Connection heating system flow/indirect cylinder 3/4”M B Connection indirect cylinder return/heating system 3/4” M

C D E F

Mains water 1/2” M Domestic hot water outlet 1/2” M Relief valve 1/2” F Recirculation 1/2” M

H G

G = 45 mm (80 l) 120 mm (120 l)

G

H = 450 mm (80 l) 600 mm (120 l)

LUNA3 COMFORT + COMBI

+

=

Dimensions (mm)

hxwxd

Combi

879x450x550

Luna3 Comfort + Combi

1642x450x550

1.240 Fi - 1.310 Fi - 1.240 i models

Dimensions (hxØ) - weight

UB 200 DC

1275x600 mm - 107 kg

UB 200 SC

1275x600 mm - 95 kg

UB 200 SC/DC

Dimensions (hxØ) - weight

UB 300 DC+

UB 300 SC+/DC+

1797x600 mm - 135 kg

UB 300 SC+

1797x600 mm - 118 kg

UB 400 DC+

1780x700 mm - 161 kg

UB 400 SC+

1780x700 mm - 144 kg

UB 400 SC+/DC+

59


Indirect cylinders Dimensions (hxØ) - weight

UBSS 250 DC

1743x545 mm - 58 kg

UBSS 260 SC

1804x545 mm - 48 kg

UBSS SC/DC

Dimensions (hxwxd) - weight

UB 200 SOLAR

1500x600x640 mm - 145 kg

UB 200 SOLAR

Dimensions (hxØ) - weight

UBSI 300

1706x610 mm - 135 kg

UBSI 300

Dimensions (hxØ) - weight

UB 500 DC

UB 1500 DC

UB 800 DC

UB 2000 SC/DC

UB 1000 SC/DC

UB 500 DC

1780x760 mm -174 kg

UB 800 DC

1905x990 mm - 235 kg

UB 1000 SC

2120x940 mm - 206 kg

UB 1000 DC

2155x990 mm - 243 kg

UB 1500 DC

2285x1200 mm - 386 kg

UB 2000 SC

2550x1300 mm - 465 kg

UB 2000 DC

2550x1300 mm - 465 kg

UB 3000 SC

2980x1400 mm - 670 kg

UB 3000 SC

Dimensions (hxØ) - weight

UBTT 1000

UBTT 1000

60

UBPT 1000

UBPT 2000

UBPU 1500 SC

2090x990 mm - 245 kg

UBPT 1000

2110x1030 mm - 210 kg

UBPT 2000

2380x1340 mm - 325 kg

UBPU 1500 SC

2150x1300 mm - 230 kg


Technical drawings - graphs - flue systems

Electric water heaters STORAGE upright 30 lt

upright 50/80/100 lt

50 lt upright 80 lt upright 100 lt upright 80 lt horizontal 100 lt horizontal

H

H1

520 760 920 760 920

360 565 760 395 555

dimensions (mm)

horizontal 80/100 lt

10-15 lt, ABOVE AND UNDER SINK

10 lt

15 lt

A

267

350

B

250

310

C

70

100

D

128

168

dimensions (mm)

61


Electric water heaters Storage thermoelectric upright 50/80/100 lt

horizontal 80/100 lt

50 lt upright TD/TS 80 lt upright TD/TS 100 lt upright TD/TS 80 lt horizontal TD/TS 100 lt horizontal TD/TS

H1

H2

520 760 920 760 920

360 565 760 395 555

165 250 250 250 250

dimensions (mm)

'

(2

'

(1

'

/

(

/

(1

(

'

H

Gas water heaters SAG2 50 - 80 - 100

SAG2 300 T

MODEL A

MODEL

A

B

C

SAG2 50

460

613

313

SAG2 80

710

863

518

SAG2 100

830

983

638

SAG2 125 T - 155 T - 195 T

MODEL

A (Âą3)

B (Âą3)

SAG2 125 T

1150

1250

SAG2 155 T

1320

1420

SAG2 195 T

1590

1730

62

SAG2 300 T 1700

B

1500

C

700

D

600

E

375

F

845

G

1235

I

140

M

620

N

100

P

1� 1/4

Q

INLET COLD WATER 1 - SHUT OFF VALVE 2 - PRESSURE REDUCER 3 - SAFETY VALVE 4 - EXPANSION VESSEL

R

HOT WATER OUTLET

S

DRAIN CONNECTION – ½â€? 5 - DRAIN VALVE

T

RECIRCULATION FITTING


Accessories for gas condensing and gas boilers Flue Systems - Coaxial flue - Dual flue - Flexible ducting system - Special accessories

64 66 68 68

Other accessories - Replacement kit - Installation templates - Solar integration

69 69 69

Hydraulic accessories

70

Outdoor installation accessories

73

Thermoregulation accessories

73

Mixing systems accessories

76

Other accessories

77

63


Flue pipe accessories Coaxial flue system for gas condensing boilers Description PP coaxial flue pipes with terminal Ø 60/100 L=750 mm supplied with windproof terminal and sealing collar

*+KHG 714093910 •

64

Code

KHG 714059613 •

PP coaxial flue pipe extension Ø 60/100 L=1000 mm

KHG 714059516 •

Coaxial flue pipe extension L=500 - Ø 60/100

KHG 714119810 •

PP coaxial flue pipe extension with checking profile - Ø 60/100

KHG 714119510 •

PP coaxial 90° bend Ø 60/100

KHG 714059717 •

Coaxial 90° bend with checking profile - Ø 60/100

KHG 714119310 •

PP coaxial 45° bend Ø 60/100

KHG 714059817 •

PP coaxial flue pipes with terminal Ø 80/125 L=1000 mm supplied with windproof terminal and sealing collar

KHG 714088910 •

PP coaxial flue pipe extension Ø 80/125 L=1000 mm

KHG 714088511 •

PP coaxial flue pipe extension Ø 80/125 L=500 mm

KHG 714088610 •

PP coaxial 90° bend Ø 80/125

KHG 714088711 •

PP coaxial 45° bend Ø 80/125

KHG 714088811 •

Internal sealing collar Ø 100

KHG 714017710 •

PP vertical chimney terminal Ø 80/125*

KHG 714093510 •

PP reduction from Ø 80/125 to Ø 60/100

KHG 714093910 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125

KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°

KHG 714093710 •


Flue pipe accessories Coaxial flue system for gas boilers Description

Code

Coaxial flue tube with terminal Ø 60/100

KHG 714101810 •

Coaxial flue tube extension Ø 60/100 L=1000 mm

KHG 714101710 •

Coaxial flue tube extension Ø 60/100 L=500 mm

KHG 714103910 •

Coaxial flue tube extension Ø 60/100 with checking profile

KHG 714104010 •

Starting coaxial 90° bend Ø 60/100

KHG 714101410 •

Coaxial 90° bend Ø 60/100

KHG 714104110 •

Coaxial 90° bend Ø 60/100 with checking profile

KHG 714101510 •

Coaxial 45° bend Ø 60/100

KHG 714101610 •

Reduction from Ø 80/125 to Ø 60/100

KHG 714119410 •

Coaxial flue tube with terminal Ø 80/125

KHG 714140610 •

Coaxial flue tube extension Ø 80/125 L=1000 mm

KHG 714140410 •

Coaxial 90° bend Ø 80/125 with checking profile

KHG 714140510 •

Telescopic coaxial flue pipe Ø 60/100

710806301 •

Coaxial reduction kit Ø 80/125 - Ø 60/100 with draining trap

KHG 714102010 •

Coaxial condensate collector kit Ø 60/100 (it replaces KHG 714087710)

KHG 714119710 •

Internal sealing collar Ø 100

KHG 714017710 •

Adapter for 45° bend/vertical chimney

KHG 714101910 •

Vertical chimney terminal for coaxial flue system

KHG 714036410 •

Flat roof tile

KHG 714036710 •

Pitched roof tile

KHG 714036610 • 65


Flue pipe accessories Dual flue system for gas condensing boilers

* In PP ** +KHG 714093810 • 66

Description

Code

Adjustable dual flue system Ø 80

710268902 •

Dual flue system Ø 80 it includes: flue reduction, intake connection

KHG 714059113 •

Vertical flue system B23 type installation*

KHG 714111011 •

Tube extension Ø 80 L=1000 mm*

KHG 714059411 •

Tube extension Ø 80 L=500 mm*

KHG 714059910 •

90° bend Ø 80*

KHG 714059211 •

45° bend Ø 80*

KHG 714059311 •

Dual flue terminal Ø 80

KHG 714010410 •

Reduction M/F from Ø 80 to Ø 60*

KHG 714075610 •

Tube extension Ø 60 L=1000 mm*

KHG 714075310 •

Tube extension Ø 60 L=500 mm*

KHG 714075210 •

90° bend Ø 60*

KHG 714075410 •

45° bend Ø 60*

KHG 714075510 •

Dual flue terminal Ø 60

KHG 714037210 •

Reduction M/F from Ø 80 to Ø 50*

710717501 •

Tube extension Ø 50 L=500 mm *

710717401 •

Tube extension Ø 50 L=1000 mm *

710705701 •

Tube extension Ø 50 L=2000 mm *

710705801 •

90° bend Ø 50*

710706001 •

45° bend Ø 50*

710705901 •

90° flue terminal Ø 50

710717601 •

Tube Ø 80 centring (pack of 5)

KHG 714037411 •

Clamp centring kit Ø 80

KHG 714106110 •

Tube Ø 60 centring kit (pack of 5)

KHG 714051510 •

Tube Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

External sealing collar Ø 80

KHG 714018411 •

Coaxial vertical chimney terminal 80/125**

KHG 714093510 •

Dual flue pipes adapter for coaxial chimney from Ø 80/80 to Ø 80/125

KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal

KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

KHG 714093710 •


Flue pipe accessories Dual flue system for fanned flue gas boilers Description

Code

Dual flue AFR system kit

KHG 714061512 •

Painted tube Ø 80 L=1000 mm

KHG 714018310 •

Painted tube Ø 80 L=500 mm

KHG 714018210 •

Aluminium tube Ø 80 L=2000 mm

KHG 714038710 •

Aluminium tube Ø 80 L=1000 mm

KHG 714038610 •

Aluminium tube Ø 80 L=500 mm

KHG 714038510 •

90° bend Ø 80

KHG 714018010 •

45° bend Ø 80

KHG 714018110 •

Painted insulated tube Ø 80 L=1000 mm

KHG 714105410 •

Painted insulated tube Ø 80 L=500 mm

KHG 714105310 •

Insulated bend 90° Ø 80

KHG 714105110 •

Insulated bend 45° Ø 80

KHG 714105210 •

Insulated tube adapter

KHG 714030510 •

Adjustable dual flue system Ø 80

KHG 714136210 •

Condensate collector kit (phasing out)

KHG 714054710 •

Condensate collector kit - Ø 80 (it replaces KHG714054710)

KHG 714119610 •

Vertical condensate collector kit Ø 80

KHG 714122810 •

Air inlet/outlet flue socket kit

KHG 714050411 •

Air outlet flue socket kit

KHG 714050311 •

Tube Ø 80 centring kit (pack of 5)

KHG 714037411 •

Clamp centring kit

KHG 714106110 •

Tube Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

Internal sealing collar for insulated tubes Ø 100

KHG 714017710 •

67


Flue pipe accessories Dual flue system for fanned flue gas boilers Description

Code

External sealing collar Ø 80

KHG 714018411 •

Dual flue vertical chimney terminal Ø 80/125

KHG 714036510 •

Flat roof tile

KHG 714036710 •

Pitched roof tile

KHG 714036610 •

Dual flue horizontal chimney terminal

KHG 714010610 •

Dual flue terminal Ø 80

KHG 714010410 •

Dual flue system for fanned flue gas boilers: Luna3 Blue Description

Code

Dual flue system kit

KHG 714017912 •

Painted tube Ø 80 L=1000 mm

KHG 714018310 •

Painted tube Ø 80 L=500 mm

KHG 714018210 •

Bend 90° Ø 80

KHG 714018010 •

Dual flue terminal Ø 80

KHG 714010410 •

Flexible ducting system for condensing boilers Description

Code

PP flexible tube Ø 80 L= 1,5 m

KHG 714105710 •

PP flexible tube Ø 80 L= 20 m

KHG 714105810 •

PP 90° bend Ø 80 with supporting bracket and condensate drainings

KHG 714105910 •

PP 90° bend Ø 80 with supporting bracket

KHG 714106010 •

Flexible centring kit Ø 80 (pack of 3)

KHG 714106210 •

Triple lips gaskets kit Ø 80 (pack of 5)

KHG 714111210 •

Special accessories in case of hard weather conditions Description

68

Code

Horizontal coaxial flue terminal Ø 60/100

KHG 714136110 •

Vertical coaxial flue terminal Ø 60/100 for gas boilers

KUG 714135710 •

Vertical coaxial flue terminal Ø 60/100 for condensing boiler

KUG 714135810 •

Vertical coaxial flue terminal Ø 80/125 for condensing boiler

KUG 714135910 •


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Other accessories: replacement kits Description

Universal replacement kit: it includes fittings and flexible stainless steel pipes

Code

KHG 714058811 •

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Code

Ecofour Fourtech Mainfour

Luna Platinum, Duo-tec, Compact, Max

Nuvola3 BS Nuvola3 Comfort

(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Installation templates Description

Luna3

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Luna3 Comfort HT Solar template

KSL 714122011 •

Metal template for Luna3 Comfort fanned flue models ▲ •

KHG 714062010 •

Metal template boilers for outdoor models

KHG 714076411 •

Silver Space

Metal template for storage boilers

KHG 714060111 •

Metal template for combi

KSL 714086411 •

Ecofour Fourtech Mainfour

Slim Slim HP

Luna3

Nuvola3 BS Nuvola3 Comfort

Comfort Combi

• For open flue and fanned flue Luna3 models. ▲

Not available for Luna3 Silver Space.

Accessories for solar integration Description

Code

KHG 714123111 •

Platinum Duo-tec (1)

Luna Platinum, Duo-tec, Compact, Max

(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Luna3 Comfort HT Solar

Luna3

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Solar valve kit

69


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Hydraulic accessories Description

Code

Platinum Duo-tec (1)

710438401 •

Luna Platinum

710351201 •

Duo-tec, Max

710351102 •

Duo-tec, Max

710351001 •

Duo-tec

710698001 •

Duo-tec Compact

Luna3 Comfort HT Solar

Luna3

Slim Slim HP

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Heating systems taps and connection pipes

Heating systems taps and connection pipes

Connection pipes for combi boiler

Connection pipes for heating only boilers

Telescopic connection pipes with heating and mains water valves

KHG 714110710 •

KHG 714107010 •

KHG 714110810 •

Hydraulic connection kit for combi boiler

Hydraulic connection kit for heating only boiler

Hydraulic connection kit with heating valves

KHG 714028910 • Telescopic connection pipes with gas inlet valve

710738801 •

Nuvola3 BS

Telescopic connection pipes

Comfort Combi

KSL 714087111 • Combi universal kit

KHG 714023310 • Vertical tube connection kit: it includes 5 tubes for vertical connection

Luna Platinum, Duo-tec, Compact, Max

KHG 714052610 •* Mains water valve without filter *

* To be used for Slim of connected with female/female adapter available on the market.

70

+ KHG 714028910 •

Slim (combi boilers)


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Hydraulic accessories Description

Code

KHG 714022011 •*

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Luna3 HT

Luna3

Slim Slim HP

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Slim (combi boilers) + 1.230 - 1.300 Fi / FiN models

Heating system flow/return valve without filter *

KHG 714052510 •

Gas valve kit

710497601 •

Luna Platinum, Duo-tec, Max

Stop valve kit to avoid installation water to get in contact with waterworks

KHG 714023211 • Stop valve kit to avoid installation water to get in contact with waterworks▲

Nuvola3 Comfort

KHG 714083810 • Stop valve kit for storage boilers to avoid installation water to get in contact with waterworks

KHG 714083910 • Stop valve kit for condensing storage boilers to avoid installation water to get in contact with waterworks

Nuvola Platinum, Nuvola Duo-tec

KHG 714021611 •

Expansion vessel (10 lt) ■

* To be used for Slim of connected with female/female adapter available on the market. ▲ Not available for Luna3 Silver Space ■ Not available for Luna3 Silver Space/Luna3 Comfort Max

71


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Hydraulic accessories Description

Code

KHG 714079711 •

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Luna3

Slim Slim HP

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Nuvola Duo-tec

Additional expansion vessel (2 lt)

KHG 714034413 •

Nuvola3 BS

Additional expansion vessel (2 lt)

KSL 714086111 •

Comfort Combi

KHG 714085210 •

KHG 714022910 •

Combi additional expansion vessel (4 lt)

Pump UPS 15/70 AO GRUNDFOS

Flow restrictor 8 l/mins▲

KHG 714022710 •

Nuvola Platinum, Nuvola Duo-tec

Nuvola3 Comfort

Recirculating kit

KHG 714106610 •

Heating only

KFG 714111910 •

Heating only

3 way valve motor

3 way valve motor and hot water temperature sensor*

Heating only

KHG 714096311 • Electric 3 way kit for external connection

KHW 714087410 • DHW sensor – pump connecting cable ▲

not available for: Luna3 Silver Space * to be used in case of heating only boilers Luna3 models for connection to any solar cylinders

72

Slim


Outdoor installation accessories Description

Code

Platinum Duo-tec (1)

(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Luna3 Comfort HT Solar

Luna3

KHG 714024811 •

24 kW

KHG 714073410 •

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Upper cover for open flue models

Upper cover for fanned flue models

Thermoregulation accessories Luna Platinum, Nuvola Platinum

(the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description

Code

Outdoor sensor for Platinum/Duo-tec

710487301 •

Wireless outdoor sensor THINK* (ONLY FOR PLATINUM BOILERS)

710302701 •

3LEDs interface THINK with support (ONLY FOR PLATINUM BOILERS)

710234002 •

5LEDs interface THINK with support (ONLY FOR PLATINUM BOILERS)

710244102 •

Wireless aerial-5 LEDs (ONLY FOR PLATINUM BOILERS)

710234301 •

Remote control THINK

710244202 •

Modulating room thermostat THINK (ONLY FOR PLATINUM BOILERS)

710106105 •

Wireless modulating room thermostat THINK* (ONLY FOR PLATINUM BOILERS)

710304401 •

Room thermostat with timer THINK (ONLY FOR PLATINUM BOILERS)

710298005 •

Wireless room thermostat with timer THINK* (ONLY FOR PLATINUM BOILERS)

710297904 •

Room thermostat

KHG 714062810 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 .) when the remote control is installed on the wall, or with the wireless aerial (710234301 .) when the remote control is installed in the boiler control panel

73


Thermoregulation accessories Luna Platinum, Nuvola Platinum

(the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description

Code

Programmable clip-in module THINK (ONLY FOR PLATINUM BOILERS)

710034502 •

Heating flow/return sensor clip-in module THINK (ONLY FOR PLATINUM BOILERS)

KHG 714078910 •

Programmable external module THINK (ONLY FOR PLATINUM BOILERS)

710503704 •

Hot water temperature sensor

KHG 714076810 •

Thermoregulation accessories Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec (the accessories dedicated to Platinum cannot be used for Duo-tec boilers) Description

74

Code

Outdoor sensor for Platinum/Duo-tec

710487301 •

Modulating thermostat (ONLY FOR DUO-TEC BOILERS)

710434701 •

Wireless modulating thermostat – it includes wireless transmitter (ONLY FOR DUO-TEC boilers)

710543001 •

Modulating room thermostat with timer (ONLY FOR DUO-TEC BOILERS)

710433601 •

Wireless modulating thermostat with timer (ONLY FOR DUO-TEC BOILERS)

710543201 •

Room thermostat

KHG 714062810 •

Hot water temperature sensor

KHG 714076810 •


Thermoregulation accessories Description

Luna3 Comfort HT Solar

Code

KHG 714062112 •

Luna3

Slim Slim HP

Slim

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Outdoor sensor

KHG 714072811

Outdoor sensor

KHG 714061610 •

Slim

KHG 714061710 •

Slim

Mechanical daily timer kit

Digital weekly timer

KHG 714106411 •

Luna3

Nuvola3 BS

KHG 714114710 •

Luna3

Remote controller and climatic regulator

Remote controller and climatic regulator wireless (already included in Luna3 Comfort Air)

KHG 714072612 •

Slim

KHG 714072511 •

Slim

Remote controller and climatic regulator

PCB interface for remote controller

KHG 714086810 •

Slim

KHG 714086711 •

Slim

KHG 714086910 •

Slim

Weekly timer and room thermostat nice time

Weekly timer and room thermostat magic time plus

Room thermostat

Fourtech Mainfour

KHG 714100510 • PCB for remote alarm signal

KHG 714106511 •

KHG 714061911 •

heating only

PCB interface for zone control

Hot water temperature sensor

LSB 710000090 •

Slim HP

LXO 000655644 •

Slim HP

Electric interface kit

Cascade controller kit

75


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Mixing systems accessories (Dimensions mm hxwxd: 600x450x160; MS models- hwxd: 700x450x160) Code

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Luna3

Slim Slim HP

Ecofour Fourtech Mainfour

Nuvola3 BS Nuvola3 Comfort

Box for universal mixing system kit “MS IN”

KHG 714128110 •

Luna

Mixing system kit “MS IN” THINK (1 HT zone- 2 LT zones)

7104769

Platinum

Mixing system kit “MS IN” THINK (1 HT zone- 1 LT zone)

7104770

Platinum

3 zones

7104823

2 zones

7104824

1 zone

7104825

• • •

• • •

• • •

• • •

• • •

• • •

Universal mixing system kit “MS IN” (1 HT zone – 1 LT zone)

KHG 71412911

Universal mixing system kit “MS IN” (1 HT zone – 2 LT zones)

KHG 71412801

Mixing system kit “MS IN” ( 2 LT zones)

KHG 71412921

Mixing system kit (*)

KFG 71407961

Additional pump to control a 3rd zone (*)

KHG 714085110 •

Kit for mixing system

Kit for mixing system

Kit for mixing system

Kit for mixing system

Kit for mixing system

Kit for mixing system

Description

Universal mixing system kit “MS IN” :

76


(1) Platinum includes: Luna Platinum, Nuvola Platinum; Duo-tec includes: Luna Duo-tec, Duo-tec Compact, Duo-tec Max, Nuvola Duo-tec

Other accessories Description

Code

Platinum Duo-tec (1)

Luna3 Comfort HT Solar

Luna3

Slim Slim HP

Ecofour Fourtech Mainfour

Installation kit separate installation Luna3 Comfort HT Solar and storage tank

KSL 714124110 •

Bottom cover

KHG 714073810 •

Polyphosphate batcher ■

KHG 714023011 •

Luna Platinum

Polyphosphate recharge (pack of 4)

KHG 714024310 •

Luna Platinum

Condensate neutralizer kit (for boilers up to 100 kW)

KHG 714125610 •

Condensate neutralizer kit recharge (for boilers up to 100 kW)

KHG 714135310 •

Nuvola3 BS Nuvola3 Comfort

Luna3 HT Solar

not available for Luna3 Silver Space/Luna3 Comfort Max

Accessories for electric water heaters Description

Code

KHI 714053511 • 4 lt expansion vessel kit for 50-100 lt electric water heaters

KHI 714063310 • Universal bracket kit for horizontal water heaters

77


Accessories for UB Inox Description

Code

UB inox

Slim UB inox

KHG 714085410 •

KHG 714084810 •

KHG 714106610 •

KFG 714111910 •

KHG 714096311 •

UB Inox additional expansion vessel

Connection kit to indirect cylinder

3 way valve motor

3 way valve motor and hot water temperature sensor*

Electric 3 way kit for external connection

KHW 714085610 •

KHW 714096810 •

Connection pump kit

Connection kit to indirect cylinder for boilers > 35 kW

KSG 714088210 • Metal template UB Inox 80-120

78


Products technical data Condensing gas boilers Gas boilers

80 81

79


80

24,7

24,7

28,9

28,9

34

33

41,2

20,6

24,7

28,9

LUNA DUO-TEC 24 (DHW)

LUNA DUO-TEC 28 (heat.)

LUNA DUO-TEC 28 (DHW)

LUNA DUO-TEC 33 (heat.)

LUNA DUO-TEC 33 (DHW)

LUNA DUO-TEC 40 (heat.)

LUNA DUO-TEC 40 (DHW)

DUO-TEC MAX 24 (heat.)

DUO-TEC MAX 24 (DHW)

DUO-TEC MAX 33 (heat.)

24,7

12,4

12,4

LUNA3 COMFORT HT 240 SOLAR (DHW)

LUNA3 COMFORT HT 120 SOLAR (heat.)

LUNA3 COMFORT HT 120 SOLAR (DHW)

NUVOLA DUO-TEC 24 (heat.)

24,7

20,6

NUVOLA DUO-TEC 16 (DHW)

20,5

16,5

NUVOLA DUO-TEC 16 (heat.)

NA3 COMFORT HT 240 SOLAR (heat.)

12,4

DUO-TEC COMPACT 24 (DHW)

NUVOLA DUO-TEC 24 (DHW)

20,6

24,7

DUO-TEC COMPACT 24 (heat.)

34

20,6

LUNA DUO-TEC 24 (heat.)

24,7

28,9

LUNA DUO-TEC 1.28

DUO-TEC COMPACT 1.24

24,7

LUNA DUO-TEC 1.24

DUO-TEC MAX 33 (DHW)

34

12,4

28,9

NUVOLA PLATINUM 33 (heat.)

LUNA DUO-TEC 1.12

24,7

NUVOLA PLATINUM 24 (DHW)

NUVOLA PLATINUM 33 (DHW)

34

20,6

28,9

LUNA PLATINUM 33 (heat.)

NUVOLA PLATINUM 24 (heat.)

24,7

LUNA PLATINUM 24 (DHW)

LUNA PLATINUM 33 (DHW)

33

20,6

24,7

LUNA PLATINUM 1.24

LUNA PLATINUM 24 (heat.)

17,4

LUNA PLATINUM 1.32

12,4

2,1

2,1

4,1

4,1

3,5

3,5

2,3

2,3

3,5

3,5

3,5

4,8

4,8

3,5

3,5

5,9

5,9

4,8

4,8

3,9

3,9

3,5

3,5

4,1

3,5

2,1

3,4

2,9

2,5

2,1

3,4

2,9

2,5

2,1

3,3

2,5

2,1

2,1

kW

kW

LUNA PLATINUM 1.18

MIN.

MAX.

Heat input

LUNA PLATINUM 1.12

PRODUCT

12

12

24

20

24

20

16

12

24

20

24

33

28

24

20

40

32

33

28

28

24

24

20

28

24

12

33

28

24

20

33

28

24

20

32

24

16,9

12

kW

MAX.

2

2

4

4

3,4

3,4

2,2

2,2

3,4

3,4

3,4

4,7

4,7

3,4

3,4

5,7

5,7

4,7

4,7

3,8

3,8

3,4

3,4

4

3,4

2

3,3

2,8

2,4

2

3,3

2,8

2,4

2

3,2

2,4

2

2

97,6

97,6

-

97,6

-

97,7

-

97,8

-

97,7

97,6

-

97,7

-

97,7

-

97,6

-

97,7

-

97,6

-

97,7

97,6

97,6

97,8

-

97,7

-

97,6

-

97,6

-

97,7

97,6

97,6

97,6

97,7

MIN. average temp. Pn 70°C kW %

Heat output

107,5

107,5

-

107,5

-

107,6

-

107,8

-

107,6

107,6

-

107,7

-

107,6

-

107,6

-

107,7

-

107,6

-

107,6

107,6

107,6

107,8

-

107,7

-

107,6

-

107,7

-

107,6

107,6

107,6

108

108

%

30%

92/42/EEC

98,1 98,1 98,1

★★★★ ★★★★

98,2 98,1

★★★★

98,3 98,2

-

98,3

★★★★

★★★★

98,2

98,2

★★★★ -

98,2 98,1

★★★★

98,2 98,2

★★★★

98,1 98,2

★★★★

98,2 98,1

★★★★

98,1 98,2

★★★★

98,2

98,2

★★★★

98,1

98,1

★★★★

-

98,1

★★★★

★★★★

98,2 98,3

★★★★

98,1 98,2

★★★★

98,1 98,1

-

98,1

★★★★

★★★★

98,2

98,2

★★★★ -

98,1

★★★★

1,9

1,9

1,9

1,9

1,8

1,8

1,7

1,7

1,8

1,8

1,9

1,8

1,8

1,8

1,8

1,9

1,9

1,8

1,8

1,9

1,9

1,8

1,8

1,9

1,9

1,7

1,8

1,8

1,9

1,9

1,9

1,9

1,8

1,8

1,9

1,9

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

73

73

73

70

80

80

75

75

80

80

80

80

80

80

80

80

80

80

80

80

80

80

80

80

80

75

80

80

80

80

80

80

80

80

80

80

75

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

98,1

0,1

75

★★★★

0,5

0,1

9,0

1,9

0,5

98,1

1,8

98,2

★★★★

CO2

★★★★

burner

not working

%

Maximum Output

stars combustion chimney radiating chimney flue number efficiency heat heat heat temp. 92/42/EEC losses losses losses max % % % % °C

Efficiency (Hi)

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

%

O2

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

34

30

30

30

30

30

30

30

30

30

30

30

30

0,006

0,006

0,012

0,010

0,012

0,010

0,008

0,006

0,012

0,010

0,012

0,016

0,014

0,012

0,010

0,019

0,016

0,016

0,014

0,014

0,012

0,012

0,010

0,014

0,012

0,006

0,016

0,013

0,011

0,009

0,016

0,013

0,011

0,009

0,015

0,011

0,008

0,006

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

exceeding flue flue air mass temp. and flow/rate max % kg/s °C

Maximum output

8,4

8,4

8,4

8,4

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

8,8

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

%

CO2

5,9

5,9

5,9

5,9

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

5,2

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

%

O2

Power consumption

39

39

39

39

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

33

30

30

30

30

30

30

30

30

30

30

30

30

0,001

0,001

0,002

0,002

0,002

0,002

0,001

0,001

0,002

0,002

0,002

0,002

0,002

0,002

0,002

0,003

0,003

0,002

0,002

0,002

0,002

0,002

0,002

0,002

0,002

0,001

0,002

0,001

0,001

0,001

0,002

0,001

0,001

0,001

0,002

0,001

0,001

0,001

297

180

297

180

102

102

112

112

104

104

102

133

133

102

102

142

142

133

133

114

114

102

102

114

102

108

145

145

130

130

145

145

120

120

130

120

110

95

90

90

90

90

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

Minimum Output

0085BS0290

0085BS0290

0085BS0290

0085BS0290

0085CL0214LU-

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CL0214

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

0085CM0140

Nr.

Certificate EEC

Product technical data condensing gas boilers


34,5

30,1

26,3

24,5

24,5

33

33

33

NUVOLA3 COMFORT 280Fi

NUVOLA3 COMFORT 240Fi

SLIM 1.230 Fi

SLIM 1.230 FiN

SLIM 1.300 Fi

SLIM 1.300 FiN

SLIM 2.300 Fi

15,1

ECOFOUR 1.14 F

NUVOLA3 COMFORT 320Fi

25,8

ECOFOUR 1.24 F

30,1

25,8

ECOFOUR 24 F

26,3

15,1

FOURTECH 1.14 F

NUVOLA3 240Fi BS

25,8

FOURTECH 1.24 F

NUVOLA3 280Fi BS

25,8

25,8

MAINFOUR 240 F

30,1

LUNA3 BLUE 280Fi

FOURTECH 24 F

26,3

26,9

LUNA3 SILVER SPACE 250Fi

26,3

33,3

LUNA3 COMFORT MAX 310Fi

LUNA3 BLUE 1.240Fi

26,9

LUNA3 COMFORT MAX 250Fi

LUNA3 BLUE 240Fi

33,3

LUNA3 COMFORT 1.310Fi

33,3

33,3

LUNA3 COMFORT 310Fi

LUNA3 COMFORT AIR 310Fi

11,9

26,9

LUNA3 COMFORT 1.240Fi

33,3

26,9

LUNA3 COMFORT 240Fi

26,9

33,3

LUNA3 1.310Fi

LUNA3 SILVER SPACE 310Fi

10,6

33,3

LUNA3 COMFORT AIR 250Fi

11,9

30,1

LUNA3 280Fi

LUNA3 310Fi

17

17

17

13,5

13,5

11,9

11,9

11,9

11,9

11,9

7,4

10,6

10,6

7,4

10,6

10,6

10,6

11,9

11,9

11,9

11,9

10,6

11,9

10,6

11,9

11,9

10,6

10,6

11,9

11,9

10,6

26,9

10,6

26,9

kW

kW

LUNA3 1.240Fi

MIN.

MAX.

Heat input

LUNA3 240Fi

PRODUCT

29,7

29,7

29,7

22,1

22,1

24,4

28

32

24,4

28

14

24

24

14

24

24

24

28

24

24

31

25

31

25

31

25

31

31

25

25

31

31

28

25

25

kW

MAX.

14,9

14,9

14,9

11,8

11,8

10,4

10,4

10,4

10,4

10,4

6

9,3

9,3

6

9,3

9,3

9,3

10,7

10,7

10,7

10,4

9,3

10,4

9,3

10,4

9,3

10,4

10,4

9,3

9,3

10,4

10,4

10,4

9,3

9,3

90,3

90,3

90,3

90

90

92,9

93,1

93,2

92,9

93,1

92,5

92,9

92,9

92,5

92,9

92,9

92,9

93,1

93,2

93,2

93,1

92,9

93,1

92,9

93,1

92,9

93,1

93,1

92,9

92,9

93,1

93,1

93,1

92,9

92,9

MIN. average temp. Pn 70°C kW %

Heat output

88,8

88,8

88,8

89,6

89,6

90,4

90,5

90,5

90,4

90,5

89,8

90,2

90,4

89,8

90,2

90,4

90,2

92,5

91,2

91,2

90,8

90,2

90,8

90,2

90,8

90,2

90,8

90,8

90,2

90,2

90,8

90,8

90,8

90,2

90,2

%

30%

92/42/EEC

Maximum Output burner

not working

93,5 94,1 94,0 93,5 92,3 92,3 92,7 92,7 92,7

★★★ ★★★ ★★★ ★★ ★★ ★★ ★★ ★★

93,6

★★★

94,0

93,6

★★★

★★★

93,6

★★★

★★★

93,8

★★★

92,9

93,4

★★★

★★★

93,8

★★★

93,3

93,4

★★★

93,3

93,8

★★★

★★★

93,4

★★★

★★★

93,8

★★★

92,9

93,8

★★★

★★★

93,4

★★★

93,3

93,4

★★★

★★★

93,8

★★★

93,3

93,8

★★★

93,3

93,8

★★★

★★★

93,4

★★★

★★★

93,4

★★★

7,3

7,3

7,3

7,7

7,7

6,5

6,0

5,9

6,5

6,0

7,1

6,7

6,7

7,1

6,7

6,7

6,7

6,4

6,4

6,4

6,2

6,6

6,2

6,6

6,2

6,6

6,2

6,2

6,6

6,6

6,2

6,2

6,2

6,6

6,6

2,4

2,4

2,4

2,3

2,3

0,6

0,9

0,9

0,6

0,9

0,4

0,4

0,4

0,4

0,4

0,4

0,4

0,5

0,4

0,4

0,7

0,5

0,7

0,5

0,7

0,5

0,7

0,7

0,5

0,5

0,7

0,7

0,7

0,5

0,5

-

-

-

-

-

0,6

0,7

0,7

0,6

0,7

0,4

0,4

0,4

0,4

0,4

0,4

0,4

0,5

0,4

0,4

0,5

0,4

0,5

0,4

0,5

0,4

0,5

0,5

0,4

0,4

0,5

0,5

0,5

0,4

0,4

159

159

159

152

152

134

142

142

134

142

115

146

146

115

146

146

149

140

135

135

145

135

145

135

145

135

145

145

135

135

145

145

140

135

135

stars combustion chimney radiating chimney flue number efficiency heat heat heat temp. 92/42/EEC losses losses losses max % % % % °C

Efficiency (Hi)

8,3

8,3

8,3

6,6

6,6

6,1

7,1

6,7

6,1

7,1

4,9

7,2

7,2

4,9

7,2

7,2

6,4

7,1

5,6

5,6

7,4

6,4

7,4

6,4

7,4

6,4

7,4

7,4

6,4

6,4

7,4

7,4

6,8

6,4

6,4

%

CO2

6,1

6,1

6,1

9,2

9,2

10,1

8,3

9,0

10,1

8,3

12,2

8,1

8,1

12,2

8,1

8,1

9,5

8,3

10,9

10,9

7,7

9,5

7,7

9,5

7,7

9,5

7,7

7,7

9,5

9,5

7,7

7,7

8,8

9,5

9,5

%

O2

41

41

41

77

77

92

65

75

92

65

139

63

63

139

63

63

83

65

109

109

58

83

58

83

58

83

58

58

83

83

58

58

72

83

83

0,016

0,016

0,016

0,015

0,015

0,018

0,018

0,022

0,018

0,018

0,012

0,014

0,014

0,012

0,014

0,014

0,016

0,017

0,018

0,018

0,018

0,017

0,018

0,017

0,018

0,017

0,018

0,018

0,017

0,017

0,018

0,018

0,018

0,017

0,017

114,6

114,6

114,6

114

114

108

108

108

108

108

100

116

116

100

116

116

119

108

106

106

110

100

110

100

110

100

110

110

100

100

110

110

110

100

100

exceeding flue flue air mass temp. and flow/rate max % kg/s °C

Maximum output

3,5

3,5

3,5

3

3

2,5

2,4

2,1

2,5

2,4

2,2

2,7

2,7

2,2

2,7

2,7

2,4

3,2

3,0

3,0

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

%

CO2

14,7

14,7

14,7

15,6

15,6

16,5

16,7

17,2

16,5

16,7

17,1

16,2

16,2

17,1

16,2

16,2

16,7

15,3

15,6

15,6

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

16,9

%

O2

Power consumption

234

234

234

290

290

368

388

457

368

388

432

333

333

432

333

333

388

266

290

290

409

409

409

409

409

409

409

409

409

409

409

409

409

409

409

0,018

0,018

0,018

0,017

0,017

0,017

0,018

0,021

0,017

0,018

0,012

0,014

0,014

0,012

0,014

0,014

0,016

0,014

0,015

0,015

0,019

0,017

0,019

0,017

0,019

0,017

0,019

0,019

0,017

0,017

0,019

0,019

0,019

0,017

0,017

170

70

170

70

170

190

190

190

190

190

120

130

130

120

130

130

130

165

135

135

165

135

165

135

165

135

165

165

135

135

165

165

165

135

135

80

-

80

-

80

75

90

90

75

90

75

75

75

75

75

75

75

90

90

90

90

75

90

75

90

75

90

90

75

75

90

90

90

75

75

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

Minimum Output

51BL1808

51BL1808

51BL1808

51BL1808

51BL1808

51BR3405

51BR3405

51BR3405

51BR3405

51BR3405

51BT3642

51BT3642

51BT3642

51BT3642

51BT3642

51BT3642

51BU3836

0085BM0323

0085BM0323

0085BM0323

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3238

51BR3279

51BR3238

51BR3238

Nr.

Certificate EEC

Product technical data gas boilers

81


82

26,3

26,3

15,4

26,3

26,3

15,4

31,1

FOURTECH 24

FOURTECH 1.24

FOURTECH 1.14

ECOFOUR 24

ECOFOUR 1.24

ECOFOUR 1.14

NUVOLA3 280i BS

17

13,5

16,5

24,5

33

24,5

33

44,4

54,1

69

SLIM 1.230 i

SLIM 1.300 i

SLIM 1.230 iN

SLIM 1.300 iN

SLIM 1.400 iN

SLIM 1.490 iN

SLIM 1.620 iN

35

27,5

23

17

13,5

17

13,5

9,5

kW

kW

SLIM 1.150 i

MIN.

MAX.

Heat input

33

kW

kW

24,5

MIN.

MAX.

SLIM 2.300 i

PRODUCT

11,9

11,9

7,1

10,6

10,6

7,1

10,6

10,6

10,6

10,6

10,6

11,9

10,6

10,6

Heat input

SLIM 2.230 i

PRODUCT

27,1

26,3

MAINFOUR 24

NUVOLA3 COMFORT 240i

11,9

19,4

LUNA3 BLUE 1.180i

27,1

19,4

LUNA3 BLUE 180i

31,1

26,3

LUNA3 BLUE 240i

NUVOLA3 240i BS

26,3

LUNA3 COMFORT 1.240i

NUVOLA3 COMFORT 280i

11,9

26,3

LUNA3 COMFORT 240i

10,6

26,3

10,6

26,3

kW

kW

LUNA3 1.240i

MIN.

MAX.

Heat input

LUNA3 240i

PRODUCT

10,4

10,4

10,4

10,4

6

9,3

9,3

6

9,3

9,3

9,3

9,3

9,3

10,4

9,3

9,3

9,3

9,3

kW

MIN.

14,9

11,8

kW

MIN.

62,2

48,7

40

29,7

22,1

29,7

22,1

14,9

kW

MAX.

31,6

24,5

20,6

14,9

11,8

14,9

11,8

8,5

kW

MIN.

Heat output

29,7

22,1

kW

MAX.

Heat output

24,4

28

24,4

28

14

24

24

14

24

24

24

17,5

17,5

24

24

24

24

24

kW

MAX.

Heat output

Maximum output

Efficiency (hi)

89,4

89,5

89,4

89,5

88,6

89,3

89,3

88,6

89,3

89,3

89,3

89,6

89,6

89,6

90,29

90,29

90,29

90,29

91,2 91,6 92,2 92,2 91,7 92,2 92,2 91,7 92,5

★★ ★★ ★★ ★★ ★★ ★★ ★★ ★★ ★★

8,3

7,5

8,3

7,5

8,3

7,8

7,8

8,3

7,8

7,8

8,4

8,8

8,8

8,6

7,7

7,7

7,7

7,7

Maximum output

91,7

91,2

★★

★★

91,4

★★

91,7

92,3

★★

92,5

92,3

★★

★★

92,3

★★

★★

92,3

★★

1,5

1,9

1,5

1,9

0,8

1,0

1,0

0,8

1,0

1,0

1,0

0,9

0,9

1,1

1,1

1,1

1,1

1,1

Efficiency (hi)

88,5

88,5 91,7

★★ 8,3

7,1

Maximum output

92,9

★★ 1,7

2,7

90,1

90

90,1

90

90,2

90

90,2

90,3

88,9

88,4

88,8

88,5

88,5

88,5

88,5

88,2

92,8 92,9 91,7 92,9 91,7 91,4 91,7 92,2

★★ ★★ ★★ ★★ ★★ ★★ ★★ ★★

7,8

8,3

8,6

8,3

7,1

8,3

7,1

7,2

2,1

1,7

1,3

1,7

2,7

1,7

2,7

2,5

92/42/EEC average 30% stars combustion chimney radiating temp. number efficiency heat heat Pn 70°C 92/42/EEC losses losses % % % % %

90

90,2

92/42/EEC average 30% stars combustion chimney radiating temp. number efficiency heat heat Pn 70°C 92/42/EEC losses losses % % % % %

90,2

90,6

90,2

90,6

90,9

91,2

91,2

90,9

91,2

91,2

90,6

90,3

90,3

90,3

91,2

91,2

91,2

91,2

92/42/EEC average 30% stars combustion chimney radiating temp. number efficiency heat heat Pn 70°C 92/42/EEC losses losses % % % % %

Efficiency (hi)

122

136

120

110

96

110

96

94

°C

flue temp.

110

96

°C

flue temp.

110

115

110

115

99

110

110

99

110

110

120

100

100

120

110

110

110

110

°C

flue temp.

5,1

5,8

4,7

4,4

4

4,4

4

4,1

%

CO2

4,4

4

%

CO2

4,9

5,2

4,9

5,2

4,1

5

5

4,1

5

5

4,7

5

5

4,9

5,3

5,3

5,3

5,3

%

CO2

11,8

10,6

12,6

13,1

13,8

13,1

13,8

13,6

%

O2

0,022

0,024

0,022

0,024

0,014

0,020

0,020

0,014

0,020

0,020

0,021

0,015

0,015

0,021

0,019

0,019

0,019

0,019

0,029

0,023

129

102

149

166

193

166

193

185

0,052

0,036

0,036

0,029

0,023

0,029

0,023

0,015

exceeding flue air mass and flow/rate % kg/s

166

193

exceeding flue air mass and flow/rate % kg/s

Maximum output

13,1

13,8

%

O2

139

125

139

125

185

134

134

185

134

134

149

134

134

139

121

121

121

121

exceeding flue air mass and flow/rate % kg/s

Maximum output

12,2

11,7

12,2

11,7

13,6

12,0

12,0

13,6

12,0

12,0

12,6

12,0

12,0

12,2

11,5

11,5

11,5

11,5

%

O2

Maximum output

108,2

110,9

99,5

94,5

96

94,5

96

89,3

°C

flue temp.

94,5

96

°C

flue temp.

82

82

82

82

83

85

85

83

85

85

86

86

86

86

85

85

85

85

°C

flue temp.

3

3,3

2,6

2,7

3

2,7

3

2,7

%

CO2

2,7

3

%

CO2

2,1

2,1

2,1

2,1

2

2,1

2,1

2

2,1

2,1

2,1

3,2

3,2

2,5

2,3

2,3

2,3

2,3

%

CO2

15,6

15,1

16,3

16,2

15,6

16,2

15,6

16,2

%

O2

457

457

457

457

485

457

457

485

457

457

457

266

266

368

409

409

409

409

0,021

0,021

0,021

0,021

0,013

0,018

0,018

0,013

0,018

0,018

0,018

0,012

0,012

0,017

0,017

0,017

0,017

0,017

75

90

75

90

75

75

75

75

75

75

75

90

90

90

75

75

75

75

Power consumption

110

110

110

110

80

80

80

80

80

80

80

110

110

110

80

80

80

80

0,023

0,017

80

80

Power consumption

120

120

290

255

350

333

290

333

290

333

0,043

0,031

0,033

0,023

0,017

0,023

0,017

0,013

15

15

15

15

15

120

120

120

-

-

-

-

-

80

80

80

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

333

290

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

Minimum output

16,2

15,6

%

O2

Power consumption

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

Minimum output

17,2

17,2

17,2

17,2

17,4

17,2

17,2

17,4

17,2

17,2

17,2

15,3

15,3

16,5

16,9

16,9

16,9

16,9

%

O2

Minimum output

51AQ338

51AQ338

51AQ338

51AQ338

51AQ338

51AQ338

51AQ338

51AQ338

Nr.

Certificate EEC

51AQ388

51AQ388

Nr.

Certificate EEC

51BR3407

51BR3407

51BR3407

51BR3407

51BT3644

51BT3644

51BT3644

51BT3644

51BT3644

51BT3644

51BU3834

0085BM0324

0085BM0324

0085BM0324

51BR3240

51BR3240

51BR3240

51BR3240

Nr.

Certificate EEC

Product technical data gas boilers


83


Quality Environment Safety

Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations

36061 BASSANO DEL GRAPPA (VI) - ITALY Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 03-12 (E)


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.