UBVT0213uk

Page 1

UBVT

Storage tanks


Comfort and flexibility of use

The new range of enameled vitrified steel UBVT is composed by 7 single or double coil models for the integration with a BAXI heat generator granting the maximum flexibility of use in different plant configurations where DHW production is required.* Model

Coil

Capacity

UBVT 200 SC

Single

200

UBVT 300 SC

Single

300

UBVT 400 SC

Single

400

UBVT 200 DC

Double

200

UBVT 300 DC

Double

300

UBVT 400 DC

Double

400

UBVT 500 DC

Double

500

(*) In case of integrated system with a heat pump or a solar, the specifier is supposed to choose the proper model of tank according to the installation type. 2


UBVT

UBVT • Internal tank made of enameled and 850° C vitrified steel that guarantees a high anti-corrosion protection • Coil thermal exchangers with a smooth and enameled surface are welded in the tank • Polyurethane foam insulation without CFC which grants minimum heat losses • ABS external covering • Magnesium anodes to protect the internal surface of the tank from corrosion • 1500 W, 2300 W, 3000 W electrical resistance with adjustable thermostat available as option

UBVT 200 SC

UBVT 200 DC

UBVT 300 SC

UBVT 300 DC

UBVT 400 SC

UBVT 400 DC

UBVT 500 DC

Primary circuit: Solar exchanger Maximum operating temperature

°C

110

110

110

110

110

110

110

Maximum operating pressure

bar

10

10

10

10

10

10

10

litres

8,1

8,1

10,1

10,1

12,1

12,1

16,8

Exchange surface

1,2

1,2

1,5

1,5

1,8

1,8

2,5

Pressure drop at 1 m³/h

kPa

1,7

1,7

2

2

2,3

2,3

2,9

Maximum operating temperature

°C

-

110

-

110

-

110

110

Maximum operating pressure

bar

-

10

-

10

-

10

10

litres

-

5,1

-

6,8

-

6,8

6,8

Exchange surface

-

0,76

-

1

-

1

1

Pressure drop at 2 m³/h

kPa

-

4

-

5

-

5

5

Power exchanged

kW

-

24

-

30

-

30

30

Maximum operating temperature

°C

95

95

95

95

95

95

95

Maximum operating pressure

bar

10

10

10

10

10

10

10

litres

200

200

300

300

395

395

500

1

2

1

2

1

2

2

Exchanger capacity

Primary circuit: Back-up exchanger

Exchanger capacity

Secondary circuit (DHW)

Water content Number of anodes

Weight

kg

95

106

113

128

140

159

186

Flow per hour (ΔT = 35 °C)

litres per hour

-

590

-

740

-

740

740

Heat losses at ΔT = 45 °C

kWh/24h

1,8

1,8

2,2

2,2

2,6

2,6

3,0

-

0,7

-

1,3

-

2,8

3,8

Performance NL

3


Dimensions UBVT 200 SC - UBVT 300 SC

UBVT 400 SC

UBVT 200 DC

UBVT 200 SC

UBVT 300 SC

UBVT 400 SC

A

287

286

304

B

753

887

C

70.5

E

UBVT 300 DC - UBVT 400 DC - UBVT 500 DC

UBVT 200 DC

UBVT 300 DC

UBVT 400 DC

UBVT 500 DC

A

287

286

304

302,6

858

B

753

887

858

948

70.5

66.3

C

70,5

70,5

66,3

71

1080

1397

1214

D

900

1127

994

1133

G

1323.5

1694

1560

E

1080

1397

1219

1358

H

1422.5

1795.5

1671.5

F

1170

1487

1309

1448

I (Ø)

610

610

710

G

1323,5

1694

1560

1665,7

H

1422,5

1795,5

1671,5

1787

I (Ø)

610

610

710

760

-I

Quality Environment Safety

S 18001

ISO

SA

9001

14001 - O H

SO

Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations

1- Domestic hot water outlet G1 2- Circulation G¾ 3- Exchanger inlet G1 4- Domestic hot water sensor G1 5- Exchanger outlet G1 6- Domestic cold water inlet + Drain opening G1 7- Solar exchanger inlet G1 8- Solar exchanger outlet G1 9- Solar sensor positioning 10- Electrical resistance seat 11- Magnesium anode 12- Thermometer

36061 BASSANO DEL GRAPPA (VI) - Italy Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 02-13 (E)