bdf-industries-solare

Page 1

OPDEXP


Active Front End regenerative unit converter Converter Active Front End acts as an AC/DC rectifier, controlling two-directions exchange of power. (absorption or power regeneration) according to the needs of the load. The control is made by a voltage loop (Bus Vdc), and a current loop, that provides sinusoidal current under any condition of load (the part of reactive power exchanged with the grid can be set by the user). ADVANTAGES AFE provides energy saving for all applications that require regeneration of energy in mains, as an alternative to the dissipative braking resistors. Regeneration unit with sinusoidal current and low harmonic content.

SPECIAL FUNCTIONS • Power factor = 1 adjustable • Mains voltage compensation • Energy Saving • Constant and high DC bus voltage, with no influence by the mains voltage fluctuation. • Bidirectional power exchange between AC mains and DC bus • Current THD lower than 3% with LCL clean power filter Main application fields • Paper machines • Metals process lines • Converting • Unwinders • Electrospindles • Test Stands • Cableways • Cranes and Hoists • Centrifuges • Cutoff applications for glass, board or metal • Renewable energy (wind, water, solar)

Convertitore rigenerativo Active Front End Il convertitore AC/DC Rigenerativo Active Front End agisce come un raddrizzatore AC/DC, controllando lo scambio bidirezionale della potenza assorbita - rigenerata, a seconda del funzionamento del carico. Il controllo si compone di un anello di tensione (Bus Vdc) e uno di corrente che fornisce corrente sinusoidale in qualsiasi condizione di carico (la quota di potenza reattiva verso la rete può essere impostata dall’utilizzatore). VANTAGGI AFE permette un risparmio energetico per tutte le applicazioni che richiedono la rigenerazione di energia in linea, in alternativa all’utilizzo di resistenze di frenatura dissipative. Unità di rigenerazione a corrente sinusoidale a basso contenuto armonico.

FUNZIONI SPECIALI • Fattore di potenza = 1 regolabile • Compensazione delle variazioni di tensione di linea • Risparmio energetico • Controllo del bus DC anche con tensione di rete fluttuante • Flusso bidirezionale della potenza • THD inferiore al 3% con filtri LCL clean power Settori applicativi • Macchine per carta • Linee lavorazione metalli • Impianti di trasformazione • Bobinatrici • Elettromandrini • Banchi prova • Impianti a fune e ascensori • Centrifughe • Applicazioni di taglio per il vetro, cartone o metallo • Energie rinnovabili (eolico, turbine ad acqua, solare)

Mains Mains

Power (kW)(kW) Power

Regenerated RegeneratedPower Power(kW) (kW)

Wind Wind Power OPDE OPDE

mini mini mini mini mini mini OPDE OPDEOPDE OPDEOPDE OPDE

Hydro Power Hydro

AFEAFE

Inverter Inverter

Regenerated Power (kW) Regenerated Power (kW) Automation Automation

OPDE OPDE

Active Active Front FrontEnd End


SOLAR POWER OPD SOLAR RENEWABLE ENERGY Thanks to the expertise in the engineering of power electronic for electric motor control, of industrial control systems and of static energy conversion, TDE MACNO launches the new generation of converters for renewable energy. OPD SOLAR OPD SOLAR inverter series allow to control photovoltaic plants and to convert energy to the grid into sinusoidal current with low harmonic content.

MODEL

OPDSOLAR

High quality components and sophisticated control algorithms are designed to ensure maximum output power and system reliability. Advanced diagnostic functions support eventual anomalies and the modular design enables quick and easy component replacement. The solar inverter is realised in industrial cabinet solution. The system is galvanically insulated from the grid through an external, low voltage, grid frequency, three phase transformer.

OPD SOLAR renewable energy Dalla pluriennale esperienza nella progettazione dell’elettronica di potenza per il controllo dei motori elettrici, dei sistemi industriali e della conversione statica dell’energia, TDE MACNO propone la nuova generazione di convertitori per le energie rinnovabili. OPD SOLAR La serie di inverter OPD SOLAR permette di controllare impianti fotovoltaici e di convertire l’energia prodotta in rete, con corrente sinusoidale a ridotto contenuto armonico.

L’alta qualità dei componenti e i sofisticati algoritmi di controllo sono stati concepiti per assicurare la massima potenza di uscita e l’alta affidabilità del sistema. Avanzate funzioni di diagnostica consentono l’identificazione di eventuali anomalie, mentre il design modulare permette la veloce e semplice sostituzione dei componenti. L’inverter viene proposto in quadro per l’utilizzo industriale. L’impianto è isolato galvanicamente dalla rete con l’utilizzo di un trasformatore trifase esterno a bassa tensione e frequenza di rete.

OPD OPD OPD OPD OPD OPD OPD OPD OPD OPD OPD OPD OPD SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR 07 10 15 19 22 27 31 41 47 66 77 99 112

OPD SOLAR 224

Input (DC) Maximum recommended PV power (kW)

7,3

11,0

16,4

20,7

23,9

26,8

36

47

Nominal input power (kW)

7,0

10,4

15,0

18,9

21,7

24,5

31,5

41,0

Max. input voltage (Voc @-10°C)

780 V

MPP range Max. input current (A)

380 V – 780 V 18,6

27,2

39,7

MPPT trackers

49,6

57,0

64,5

83,0

54

76

89

47,1

66,0

77,7

113

128

257

98,9

112,1

2 x 112,1

780 V

780 V

780 V

380 V – 780 V

380 V – 780 V

380 V – 780 V

107,8 123,9 173,5 204,5 260,1 294,9

1

1

1

2 x 294,9 2

Output (AC) Nominal output power (kW)

6,1

9,1

13,7

17,3

19,9

22,3

30,1

39,1

45,0

63,0

74,2

Nominal output current (A)

8,8

13,2

19,8

24,9

28,70 32,20

43,5

56,5

64,9

90,9

107,2 136,3 154,5

309,0

Connection type

94,4

107,1

214,2 kW

three phase

three phase

three phase

three phase

Transformer

external

external

external

external

Grid voltage

400 Vac ± 10%

400 Vac ± 10%

400 Vac ± 10%

400 Vac ± 10%

Grid frequency

50 Hz ± 2%

50 Hz ± 2%

50 Hz ± 2%

50 Hz ± 2%

Power factor (cosφ)

1 (adjustable)

1 (adjustable)

1 (adjustable)

1 (adjustable)

< 3%

< 3%

< 3%

< 3%

THD Mechanical characteristics Dimensions (H x W x D mm) Weight (kg)

1510 x 800 x 600

2000 x 1000 x 600

2200 x 1200 x 600

2200 x 1600 x 600

2200 x 2400 x 600

170

350

450

600

750

General data Protection class

IP44

IP23

IP23

IP23

Cooling concept

air cooled

air cooled

air cooled

air cooled

-10°C ÷ +40°C

-10°C ÷ +40°C

-10°C ÷ +40°C

-10°C ÷ +40°C

Working temperature Humidity (without condensation) Communication

< 95% RS485 – CAN Open – Profibus – Modbus – GSM – Ethernet


OPD SOLAR INVERTERS HAVE BEEN DESIGNED TO GRANT MAXIMUM EFFICIENCY IN ANY condition, UP TO 98%

Gli inverter OPD SOLAR sono concepiti per fornire la massima resa in tutte le condizioni con un’efficienza di punta pari a 98%

GENERAL CHARACTERISTICS • Power range from 7 kW to 224 kW • Turn key solutions for electric cabinets • “Maximum Power Point Tracking” control algorithm (MPPT) to get the max power from the photovoltaic plant in any operating condition • Max DC voltage: 780 V • Operation at 100% rated power up to +40° temperature • Built-in interface protection and general protection device • Built-in overcurrent protection

CAratteristiche generali • Potenze da 7 kW a 224 kW • Soluzioni chiavi in mano di quadri elettrici • Algoritmo intelligente “Maximum Power Point Tracking” per prelevare la massima potenza dal campo fotovoltaico in qualsiasi condizione operativa. • Tensione DC massima 780 V • Funzionamento a 100% di potenza nominale sino a temperature di +40° • Protezione di interfaccia e dispositivo di protezione generale integrati • Protezione per sovracorrente integrata (di serie)

Solar panels

Central Inverter

MODULARITY All OPD SOLAR inverters can be connected in parallel

to grant plant power up to 1 MW. MAIN SWITCH Integrated AC and DC breaker enable simple isolation of the power inverter. TRANSFORMER (EXTERNAL) With the efficiency optimised isolating transformer, the DC side is decoupled from the potential of the AC side. The earthing of a DC pole - as prescribed for the operation of thin-film modules - is admissible. It is optional for any configuration that requires the connection in parallel of more trasformless inverters. DATA COMMUNICATION Via RS485, RS422, Ethernet, Can-Bus, Profibus. Telediagnosis possible. OVERVOLTAGE PROTECTION Built-in overvoltage protectors limit the voltage and prevent failures due to lighting strikes, switching operations and atmospheric disturbances. FILTERS The employed filters in conjunction with dynamic current control produce a line current with a quality that exceeds standard requirements. The current distortion THD is lower than 3%.

OPD Solar 100kW

Solar OPD Solar OPD Solar + OPD 100kW + 100kW + 100kW =

Trasf. 400kW

MODULARITÀ Tutti gli inverter OPD SOLAR possono essere collegati in parallelo per garantire potenze di impianto fino a 1 MW. INTERRUTTORI PRINCIPALI Gli interruttori che permettono il distacco dagli stadi AC e DC garantiscono un semplice isolamento dell’inverter di potenza. TRASFORMATORE (esterno) Grazie all’utilizzo di un trasformatore di isolamento di elevata efficienza, lo stadio AC è disaccoppiato dal potenziale dello stadio DC, come prescritto per poter operare con moduli fotovoltaici con tecnologia thin-film. È opzionale per ogni configurazione che prevede il collegamento in parallelo di più inverter trasformless. COMUNICAZIONE DATI Comunicazione dati via RS485, RS422 Ethernet, Can-Bus, Profibus, possibilità di tele-diagnostica. PROTEZIONE DI OVERVOLTAGE Condizioni di overvoltage possono verificarsi, in presenza di fulmini e durante le fasi di commutazione. I circuiti di protezione di overvoltage integrati limitano la tensione prevenendo i guasti. FILTRI I filtri impiegati, unitamente all’elevata dinamica di controllo della corrente, consentono di generare una corrente di linea con una qualità che eccede i requisiti standard. Il fattore di distorsione THD è inferiore al 3%.


Wind and OPDEXP Water Power IL GENERATORE TRASFORMA L’ENERGIA CINETICA DEL VENTO E DELL’ACQUA in energia elettrica. TDE MACNO ha sviluppato la nuova serie di convertitori di frequenza OPDE, particolarmente indicati per il controllo dei generatori EOLICI E IDROELETTRICI A VELOCITÀ VARIABILE, ASINCRONI E SINCRONI A MAGNETI PERMANENTI.

THE GENERATOR CONVERTS THE KINETIC ENERGY INTO ELECTRIC ENERGY. TDE MACNO has developed the new series of converters OPDE, ideally suited for the control of asynchronous and synchronous WITH PERMANENT MAGNETS GENERATORS FOR WIND AND WATER TURBINES. The system is composed of 2 inverters: one connected to the generator, and one (AFE) to the grid. The first inverter (AC / DC) adjusts the charge to the generator, by converting the generated energy from AC into DC. The second one, properly synchronized to the grid, regenerates the energy, by converting it from DC into AC, with sinusoidal currents in phase with the grid voltage. A special LCL filter ensures a low harmonic content of the current.

The AFE converter, connected to the grid, precharges the DC bus voltage to a base level, by calculating simultaneously the grid phase angle. Once the kinetic energy produced from the wind turbine exceeds the preset limits, the generator powers the inverter that converts the exceeded energy charging the DC bus. Solar panels This energy is then converted from the AFE to the grid with low THD values and with adjustable unity power factor.

Il sistema è composto da 2 inverter: uno verso il generatore e uno (AFE) verso la rete. Il primo (AC/DC) regola il carico al generatore, convertendo l’energia generata da AC a DC. Il secondo, opportunamente sincronizzato in rete, rigenera l’energia convertendola da DC a AC, con correnti sinusoidali in fase con la tensione di rete. Un opportuno filtro LCL garantisce una basso contenuto armonico delle correnti.

AC/DC Inverter

Il convertitore AFE collegato alla rete, precarica il DC bus ad un livello base e calcola contemporaneamente l’angolo di fase della rete. Una volta che l’energia cinetica prodotta dalla turbina eolica supera i limiti preimpostati, il generatore eroga energia all’inverter che la converte caricando il bus DC. Questa energia Central dall’AFE viene a sua volta convertita Inverter verso la rete, con bassi valori di THD e fattore di potenza unitario o regolabile.

AFE

+

OpenDrive EXP (400 V)

Size

S

M

L

X

1

2

3

03

07

12

15

22

32

40

48

60

70

90

110

150

175

220

250

310

370

460

55

75

90

132

132

160

200

250

Overload 120% x 30s

POWER kW

1,5

3

5,5

7,5

11

18,5

22

22

37

37

45

I rates ( A rms)

3,6

8,3

14,2

17,8

26

37,9

47,4

54,5

68,1

79,3

103

Overload 150% x 30s

POWER kW

1,5

3

5,5

7,5

11

15

18,5

22

30

37

I rates ( A rms)

3,2

7,4

12,6

15,8

23,2

33,7

42,2

48,5

60,6

70,6

Overload 200% x 30s

POWER kW

1,1

2,2

4

5,5

7,5

11

15

18,5

22

30

37

I rates ( A rms)

2,6

6

10,2

12,8

18,8

27,3

34,2

39,3

49,1

57,2

74,3

Overload POWER kW 200% x 3s I +155% x 30s rates ( A rms)

1,5

3

5,5

7,5

11

15

18,5

22

30

30

37

45

55

75

110

110

132

160

200

3

7

12

15

22

32

40

46

57,5

67

87

100

140

165

210

238

294

350

441

Sizes (H x W x D mm)

303 89 253

Weight (kg)

3,5

Approvals

303 116 253 4,8

322 137 253 5,5

6,4

322 194 273 9,3

10 CE

118,4 165,8 195,4 248,6 281,8 348,1 414,4 522,1

45

55

75

90

110

132

160

200

250

91,7 105,4 147,6 173,9 221,3 250,9 309,9 368,9 464,8 45

55

75

90

110

132

160

200

85,4 119,6 140,9 179,3 203,3 251,1 298,8 376,6

675 251 290

900 478 296

900 678 296

22

65

80


ver.05/2012 - studiobrand.it

OPDEXP TDE MACNO Tecnologie Digitali Elettroniche S.p.A. Via dell’Oreficeria, 41 36100 Vicenza - Italy TEL. +39 0444 343555 FAX. +39 0444 343509 info@tdemacno.it www.tdemacno.it

Group


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.