iGuzzini - Trunking system, Regelle, Incassi

Page 1

Trunking system T16 - Reglette T16 - Incassi T16


Trunking system T16 - Reglette T16 - Incassi T16 iGuzzini

Catalogue news 2005 This catalogue introduces the New Products for Indoor and Outdoor Lighting Systems for the year 2005.

Internal Lighting Systems The internal catalogue illustrates internal fittings.

External Lighting Systems This catalogue presents the whole iGuzzini range of external fittings

Trunking system T16

Reglette T16

Incassi T16

page 2

page 11

page 14

1


2


Trunking system T16 iGuzzini

Continuous lines, simplicity and functionality, easy installation, excellent illumination of any environment - these are the characteristics that resulted in the development of the new modular Trunking System T16. The structural modules up to 4.4 m long and the

High output

possible choice among different wattages, wirings and light emissions make this system suitable for different applications such as commercial centres, shops, supermarkets, offices, walking areas, warehouses.

Down-light and up/down-light emission

Dark VDU

3


Trunking system T16 design J. M. Wilmotte

iGuzzini

Version with visible lamps

Wide flood

Version with white flood reflector

Version with white flood reflector

Down light

Up - Down light

Version with white flood reflector and louvre

Version with white flood reflector and louvre

Down light

Up - Down light

Version with L<1000cd/m2 α>65° laminated optics

Version with L<1000cd/m2 α>65° laminated optics

Down light

Up - Down light

This system uses T16 lamps that guarantee superior light flow and improved high end performance compared to traditional T26 lamps. Reflectors, louvres, and optics may be added, making the system ideal for different uses and spaces. The standard model has visible lamps with light emission that is intended for basic lighting and secondary space lighting. The addition of flood reflectors, thanks to their superior yield, is recommended for supermarkets and commercial spaces. 4

The louvre, which is installed onto the flood reflector, acts as a screen for the lamps and gives off a good level of visual comfort; while the laminated optic made of mirrored aluminium with a bi parabolic profile, combined with the flood reflector, allows us to install this system in offices where monitors are present. The flood reflectors are also available with up-down light emission.The uplight component represents 3% of the total light flow and is considered to be ambiance lighting.


Trunking system T16 design J. M. Wilmotte

iGuzzini

The T16 Trunking system can be either ceiling-mounted or suspended with a steel cable or a chain. The steel cable suspension is made possible by the special accessory kit that has a precision adjustment system for the cable combined with a ceiling attachment (items 6990+6991).

0,5 m max

2,5 m max

0,5 m max

The clip clicks easily into place on the structure. The superior rigidity of the fitting’s structure allows us to position the clips at a maximum distance of up to 2,5 metres one from the other, and at a maximum of 0,5 metres from the beginning or the end of the row.

Ceiling mounted installation via the special ceiling mounting attachment (item number 6990).

Pendant installation with the chain is made possible by a clip for chain accessory installation (item number 6992). Chain not included.

Simple and easy installation.

The clips for ceiling mounting or suspension are clipped onto the modular structure.

Once a lighting row of modular structures is ready, just select the desired switches from the connecting plate (modules have three separate switching devices).

The reflector is secured without tools by using the same mounting system as the connecting plates.

The end modules are equipped with an electric connector for the system’s power supply, and should always be positioned at the beginning of the row.

The connecting plates are easily positioned thanks to the presence of fixed mechanical reference points on the modular structures.

Lamps are installed.

The intermediate modular structures are equipped with mechanical connecting joints and electrical connectors that connect the modules to each other.

No tools are required to secure the connecting plates to the module. They can be positioned so that a lighting row can be created or they may also be positioned so that there is an empty space equivalent to their length or a multiple of their length.

No tools are required to install the louvre or the optic to the flood reflector.

5


Trunking system T16 design J. M. Wilmotte

iGuzzini

System specifications item no. 6992 Clip for suspension installation with chain for module

item no. 6990 + 6991 Ceiling attachment for module + suspension cable kit

item no. 6990 Ceiling attachment for module

1 End module, with 5x2,5 mm2 cables for connecting plate: - 54W (item no. 3725-3726-3727) - 35/80W (item no. 3728-3729-3733)

Intermediate module equipped with joint, with 5x2,5 mm2 cables for connecting plate: - 54W (item no. 3774-3775-3776) - 35/80W (item no. 3777-3778-3779)

Intermediate module equipped with joint and three-phase track for spotlights with adapter (item no. 3788)

The track is configured for installation of iGuzzini spot lights: Le Perroquet Connecting plate for modules, equipped with electronic power supply

Buffer barrier for modular structure - 54W (item no. 6978) - 35/80W (item no. 6979)

Parallel

2

Trimmer

3 Metro

2

Gabbiano White down light reflector for connecting plate: - 54W (item no. 6980) - 35/80W (item no. 6981)

White up-down light reflector for connecting plate: - 54W (item no. 6982) - 35/80W (item no. 6983)

Down light version

Up-down light version

Shuttle

Woody /Miniwoody

Vela

Cestello

6

Metal louvre for down light reflectors and up-down light with for connecting plate: - 54W (item no. 6986) - 35/80W (item no. 6987)

Laminated optic in mirrored aluminium for down light and up-down light reflectors for connecting plate: - 54W (item no. 6984) - 35/80W (item no. 6985) L<1000cd/m2 ι>65°

Down light version (matched with the white down light reflector)

Down light version (matched with the white down light reflector)

Up-down light version (matched with the white up-down light reflector)

Up-down light version (matched with the white up-down light reflector)

1 End caps are included with the end module

2 End caps for reflector (two) item no. 6988

3 Connecting joints for reflector (two) item no. 6989


Trunking system T16 iGuzzini

• Modular assembly system for lighting rows for use with T16 lamps. • The technical characteristics of the fitting comply with EN60598-1 standard. • IP20 • IMQ approval • ENEC seal • F seal • Class of Insulation I • GWT 850°C

Connecting plates: • Made of painted galvanized steel sheet. • Equipped with electronic reactor. • Electrical connection to the modular structure with connectors that have a switch for the three different power lines. • Mechanical and electrical connection to the track module via a fastening system with a 1/4 - turn. No tools necessary.

Modular structures: • Made of painted galvanized steel sheet. • Modules are cable-ready with 5x2,5 mm2 cables, and connectors have three separate switching devices. • End modular structure: equipped with quick connection system (mechanic and electric) to connect the module to the lighting row; equipped with two polycarbonate end caps ready for pass-through electric cables. • Intermediate modular structure: equipped with joint and 2 connectors for quick connection (mechanic and electric) to the lighting row. • Intermediate modular structure with 3-phase track: module complete with electrified 3-phase track for spotlights with iGuzzini adaptors; equipped with joint and 2 connectors for quick connection (mechanic and electric) to the lighting row.

Reflectors and optics: • Reflectors made of painted galvanized steel sheet. Mechanical connection to the connecting plate via a fastening system with a 1/4 turn. No tools necessary. End caps and accessory alignment joints made of painted galvanized steel sheet. • Louvre made of painted galvanized steel sheet; installation directly onto the reflector without tools; safety cables. • Laminated optic with bi-parabolic profile made of anodized mirrored ultrapure aluminium; controlled luminance: L≤1000 cd/m2, α>65° (EN 12464-1); installation directly onto the reflector without tools; safety cables.

Simulation

design J. M. Wilmotte

L1 L2 L3

Easy installation

Pre-wired structural modules

Safety cable

Preconfigured to switch on 3 different groups of fittings separately

7


Trunking system T16 design J. M. Wilmotte

iGuzzini

01

code

lamp

lenght 45

End modular structure, with 5x2,5 mm2 cables for 54W connecting plate, equipped with two end caps 3725 single module 1180 3726 double module 2360 3727 triple module 3540

60

End modular structure, with 5x2,5 mm2 cables for 35/80W connecting plate, equipped with two end caps 3728 single module 1480 3729 double module 2960 3733 triple module 4440

45

Intermediate modular structure equipped with joint, 5x2,5 mm2 cables and 54W connecting plate 3774 single module 1180 3775 double module 2360 3776 triple module 3540

60

Intermediate modular structure equipped with joint, 5x2,5 mm2 cables and 35/80W connecting plate 3777 single module 1480 3778 double module 2960 3779 triple module 4440 Connection couplings included in the sizes

60

180°

90°

35 W

250

T 16 - G5

60

0° C0-180 γ=20° CIE

Imax=172 cd/Klm

180°

90°

2x35W T 16 - G5

8

nL 0.97 33-61-83-73-97 UGR 30.5-24.0 DIN 90° B.31 UTE 0.71H+0.26T F"1=329 F"1+F"2=609 F"1+F"2+F"3=831 CIBSE BZ6

84

C0-180 γ =20° CIE

Imax=172 cd/Klm

84

Connecting plate for modular structures equipped with electronic power supply 6972 1x35W T16 1480 6973 1x54W T16 1180 6974 1x80W T16 1480 6975 2x35W T16 1480 6976 2x54W T16 1180 6977 2x80W T16 1480

55

Intermediate modular structure equipped with joint and 3-phase track for spotlights with adaptor 3788 2640

250

nL 0.97 33-61-83-73-97 UGR 32.9-26.4 DIN 90° B.31 UTE 0.71H+0.26T F"1=329 F"1+F"2=609 F"1+F"2+F"3=831 CIBSE BZ6

60


Trunking system T16 design J. M. Wilmotte

iGuzzini

01

lenght nL 0.82 43-78-97-100-82

180°

35 W

90° UGR 22.2-22.8

DIN A.40 UTE 0.82E+0.00T F"1=435 F"1+F"2=784 F"1+F"2+F"3=971 CIBSE BZ4

350

T 16 - G5

C0-180 γ=12° CIE

nL 0.76 45-80-97-100-76

180° 90°

White up-down light reflector L=1480 for 35/80W connecting plate 6983 1480

90° UGR 23.4-24.8

DIN A.40 UTE 0.76F+0.00T F"1=447 F"1+F"2=800 F"1+F"2+F"3=974 CIBSE BZ4

350

T 16 - G5

White up-down light reflector L=1180 for 54W connecting plate 6982 1180

0° C0-180 γ=13° CIE

Imax=254 cd/Klm

nL 0.83 43-78-97-97-83

180° 90°

35 W

90° UGR 22.1-22.8

DIN A.42 UTE 0.81E+0.02T F"1=430 F"1+F"2=778 F"1+F"2+F"3=967 CIBSE BZ4

350

T 16 - G5

C0-180 γ=13° CIE

nL 0.77 43-78-97-97-77

180° 90°

Metal louver for down light and updown light reflectors with L=1480 for 35/80W connecting plate 6987 1480

DIN A.42 UTE 0.77E+0.02T F"1=430 F"1+F"2=778 F"1+F"2+F"3=967 CIBSE BZ4

Imax=249 cd/Klm 90°

35 W

90° UGR 24.3-25.0

350

T 16 - G5

Metal louver for down light and updown light reflectors with L=1180 for 54W connecting plate 6986 1180

C0-180 γ=24° 180° 90°

300

T 16 - G5

nL 0.66 52-85-97-95-66

90° UGR 20.4-18.6

Imax=407 cd/Klm 90°

35 W

DIN A.42 UTE 0.63D+0.03T F"1=520 F"1+F"2=853 F"1+F"2+F"3=968 CIBSE BZ3

300

T 16 - G5

Laminated optic made of mirrored aluminium for down light and up-down light reflectors with L=1480 for 35/80W. L<1000cd/m2 α>65° connecting plate 6985 1480

C0-180 γ=36° 180° 90°

525

T 16 - G5

180°

180

nL 0.66 71-99-100-96-66

90° UGR 16.8-13.9

90°

35 W

CIE nL 0.62 72-99-100-100-62 UGR 18.5-14.4 DIN A.60 UTE 0.62B+0.00T F"1=721 F"1+F"2=993 F"1+F"2+F"3=999 CIBSE LG3 L<500 cd/m2 at 65° BZ1

C15-195 γ=32° CIE

Imax=410 cd/Klm

T 16 - G5

180

C0-180 γ=23° CIE 180°

90°

Laminated optic made of mirrored aluminium for down light and up-down light reflectors with L=1180 for 54W. L<1000cd/m2 α>65° connecting plate 6984 1180

CIE nL 0.63 52-86-97-100-63 UGR 20.8-18.9 DIN A.40 UTE 0.63D+0.00T F"1=524 F"1+F"2=856 F"1+F"2+F"3=971 CIBSE BZ3

Imax=248 cd/Klm

35 W

180

Imax=240 cd/Klm

2x35W

180

Imax=247 cd/Klm

2x35W

112

90°

112

White down light reflector L=1480 for 35/80W connecting plate 6981 1480

C0-180 CIE

Imax=262 cd/Klm

112

White down light reflector L=1180 for 54W connecting plate 6980 1180

113

code

450

DIN A.62 UTE 0.63B+0.03T F"1=705 F"1+F"2=990 F"1+F"2+F"3=998 CIBSE LG3 L<500 cd/m2 at 65° BZ1

9


Trunking system T16 design J. M. Wilmotte

iGuzzini

accessories code

lenght

Buffer barrier for modular structure 6978 1180 6979 1480

code

Connecting joints for reflector (two) 6989 for 6980-6981-6982-6983

Available in colour 01 Available in colour 00 End caps for reflector (two) 6988 for 6980-6981-6982-6983 Available in colour 01

installation systems code

lenght

code

Ceiling mounted attachment for modular structure. 6990

Clip for suspension installation with chain for modular structure 6992

Available in colour 00

Chain not included. Available in colour 00

Kit includes steel suspension cable and precision adjustment. 6991 3000 Utilized in conjunction with item 6990. Available in colour 00

10


Reglette T16 iGuzzini

• Easy installation and maintenance operations because of quick connecting cover. • No tools needed to install accessories. • The technical characteristics of the fitting comply with EN60598-1 standard. • IP20 • ENEC seal • F seal • Class of Insulation I • GWT 960°C

High output

Pass-through cables

Photo: Marcel Schläfle

• Luminaire for use with T16 lamps. • Body and cover made of 0,4 mm steel sheet. White painted surface, body’s interior surface and cover have a transparent paint treatment; lamp holder made of self-extinguishing polycarbonate; self-extinguishing polycarbonate end caps. • Reflector accessory made of 0,5 mm steel sheet; white paint finish. • Light dispersing grille accessory made of 0,5 mm steel sheet; white powder coated paint finish. • Single-lamp and two-lamp versions; electronic and DALI digital dimmable electronic control gear. • End caps ready for pass-through electric cable. • Safety cable.

Zurich - Swiss: Mc Connell

design iGuzzini

Safety cable

Dimmable versions DALI

11


Reglette T16 design iGuzzini

iGuzzini

Reglette luminaires use state of the art T16 fluorescent lamps. The electronic or DALI dimmable digital control gear allows the luminaires to reach high-end quality of light, as well as the possibility of adjustment of the light flow in response to changing lighting necessities (for the DALI version). The luminaires that have exposed lamps allow the user to have up to 360째 of space lighting; the reflector accessories concentrate most of the

Version with exposed lamps

Version with metal reflector

Version with metal reflector and light dispersing grille

Installation operations are easy and require a reduced use of tools. The metal cover has a quick hook system. The reflector accessories and light dispersing grilles can be installed simply with no tools. The cable fastens the cover and reflectors to the luminaire body, making the product safer and the installation operations easier.

12

light; the light dispersing grille limits the direct glare from the lamps thereby increasing visual comfort. The luminaires distinct characteristics make them ideal for general lighting (for commercial spaces, schools, libraries, and high traffic areas for example) in areas that also need to keep energy consumption at a minimum.


Reglette T16 design iGuzzini

iGuzzini 08

01

lamp

length

75

code

Luminaire with electronic control gear 3700 14 W T16 575 3701 21 W T16 875 3702 28 W T16 1175 3703 35 W T16 1475 3704 54 W T16 1175 3705 80 W T16 1475 Luminaire with digital dimmable electronic (DALI) control gear 3706 28 W T16 1175 3707 35 W T16 1475 3708 54 W T16 1175 3709 80 W T16 1475

55

L

68

1x35W

63

Luminaire with electronic control gear 3722 2x28 W T16 1175 3723 2x35 W T16 1475 3724 2x54 W T16 1175 IP20

L

2x35W

accessories

97

code

104

130

130

length

Metal reflector 6931 575 for 3700 6932 875 for 3701 6933 1175 for 3702-3704-3706-3708-3722-3724 6934 1475 for 3703-3705-3707-3709-3723 Metal light dispersing grille 6968 575 for 3700 6969 875 for 3701 6970 1175 for 3702-3704-3706-3708-3722-3724 6971 1475 for 3703-3705-3707-3709-3723

1x35W

2x35W

1x35W

2x35W

The light dispersing grille should be used along with the metal reflector.

Suspension cable kit 6991

3000

13


Incassi T16 design iGuzzini

iGuzzini

Simulation

• Recessed fittings for false ceilings for use with T16 lamps. • Steel sheet body with welded corners. Support structure for optics made of steel sheet. • Powder coated paint finish. • Double parabolic reflecting surfaces treated with an anti-glare and an anti-iridescent anodizing process with low luminance and mirrored finish (MIR04) or semi-satin finish (MIR08). • Controlled luminance L≤200 cd/m2 for α>65° in all directions, ideal for use in spaces with monitors in compliance with EN 12464-1. • Optical group can be opened without tools; retention safety system, ground connecting cable. • Quick connecting electric terminal blocks; possibility of pass-through cables.

• Available in versions with electronic power supply and emergency light with inverter. • Emergency versions equipped with inverter and battery group; permanent one-hour emergency light. • Can be installed on modules with 600/625 mm standard spacing. • Installation in false ceilings with hidden structures via special rods, which are available as accessories • The technical characteristics of the fitting comply with EN60598-1 standard. • IP20 • ENEC seal • F seal • Class of Insulation I • GWT 960°C

55

High output

14

Easy installation

Safety cable

Protection film

Quick-connecting terminal blocks

Controlled luminance

Reduced height

Emergency version


Incassi T16 design iGuzzini

iGuzzini

These recessed fittings use state of the art T16 lamps. The electronic control gear allows the user to obtain an elevated quality of light along with a reduced energy consumption. Thanks to these characteristics, the luminaires respond to the needs of maintenance, safety, and reduced energy consumption in public areas and common spaces.

They are particularly indicated for offices with monitors (in compliance with EN12464-1), retail spaces, and schools. The optics made of polished or semi-satin finish aluminium consent an optimal control of the light flow and a high yield.

Semi-satin finish aluminium optics. Controlled luminance L≤200 cd/m2 for α>65°

Aluminium mirrored optics. Controlled luminance L≤200 cd/m2 for α>65°

Grid installation

Installation via fastening rods

The fittings can be installed into structured false ceilings or via the accessory rods. They can be installed into false ceilings with a hidden structure or plasterboard. The reduced height of the fittings, the safety cables, the hooking system of the central cover, and the quick connecting terminal blocks make installation quite easy. Also the fittings can be installed into false ceilings that have reduced dimensions.

15


Incassi T16 design iGuzzini

iGuzzini 08

01

Kit of fastening rods for false ceilings with hidden structures, to be ordered separately lamp

dimensions

Dark light recessed fitting with mirrored optics L≤200 cd/m2 α>65° with electronic control gear 2650 3x14 W T16 596x596 Dark light recessed fitting with 2 mirrored optics L≤200 cd/m α>65° with electronic control gear and permanent emergency light 2651 3x14 W T16 596x596

570 55

code

596 /621

580x580

IP20

Kg.

2650 2651 4,30 5,10

Semi-satin recessed optics L≤200 cd/m2 α>65° with electronic control gear 2652 3x14 W T16 596x596 2658 3x14 W T16 621x621 Semi-satin recessed optics 2 L≤200 cd/m α>65° with electronic control gear and permanent emergency light 2653 3x14 W T16 596x596 IP20

2652 2653 4,30 5,10

Dark light recessed fitting with mirrored optics L≤200 cd/m2 α>65° with electronic control gear 2654 4x14 W T16 596x596 Dark light recessed fitting with 2 mirrored optics L≤200 cd/m α>65° with electronic control gear and permanent emergency light 2655 4x14 W T16 596x596 IP20

Kg.

2654 2655 4,40 5,20

Semi-satin recessed optics L≤200 cd/m2 α>65° with electronic control gear 2656 4x14 W T16 596x596 2659 4x14 W T16 621x621 Semi-satin recessed optics 2 L≤200 cd/m α>65° with electronic control gear and permanent emergency light 2657 4x14 W T16 596x596 IP20

Kg.

2656 2657 4,40 5,20

Kit of fastening rods for false ceilings with cross sections of 8 to 40mm 6924 Available in colour 00

16

570 55

Kg.

596 /621

580x580


Turn static files into dynamic content formats.

Create a flipbook