Hunnewell Drawing Set

Page 1

New Residence

New Residence 220 Hunnewell Street

220 Hunnewell St. Needham, MA

NEEDHAM, MA

November 18, 2011 GENERAL NOTES

OWNER

CODE MASSACHUSETTS STATE BUILDING CODE 8TH EDITION

1. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECTS OF ALL DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND EXISTING CONDITIONS.

2. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS THAT MAY APPLY TO THE CONSTRUCTION OF THE PROJECT.

3. ALL WORK OF THIS PROJECT SHALL COMPLY WITH ACCEPTED BUILDING PRACTICES AND ALL CODE HAVING JURISDICTION OVER THIS PROJECT.

GOVERNMENT BUILDING CODE

10. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. THE CONTRACT DRAWINGS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK.

- BUILDING PLANS ON SITE AT REASONABLE TIMES (5111.11) - BUILDING PERMIT ON SITE PROMINENTLY DISPLAYED (5111.14)

THE MASSACHUSETTS BUILDING CODE, 8TH EDITION

- SITE GRADING/DRAINAGE: THE GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10' (USED TO BE 1/2 PER FOOT FOR 6') (5401.3)

11. DIMENSIONS ARE TO CENTER LINES, EXISTING BULDING GRID LINES OR TO FACE OF FINISHED SURFACE UNLESS OTHERWISE NOTED.

- PIPES THROUGH FOOTINGS OR FOUNDATION WALLS: ANY PIPE PASSING THROUGH A FOOTING OR FOUNDATION WALL REQUIRES A SLEEVE (2) SIZES GREATER THAN THE PIPE. (7602.5)

12. ALL GYPSUM WALL BOARD CONSTRUCTION SHALL CONFORM TO RECOMMENDATIONS, PRACTICES, STANDARDS AND INSTRUCTIONS PUBLISHED BY U.S. GYPSUM COMPANY IN THE GYPSUM CONSTRUCTION HANDBOOK.

- FOUNDATION DRAINAGE: CONCRETE OR MASONRY FOUNDATIONS; DRAINS SHALL BE PROVIDED (5401.3)(5405.1)

4. REFER TO LIMITS OF WORK DRAWINGS FOR OVERALL DISCRIPTION OF WORK AREAS.

5. THE GENERAL CONTRACTOR SHALL LEAVE THE PROJECT SITE AND ALL SURROUNDING AREAS IN FINAL CLEAR CONDITION INCLUDING THE REMOVAL OF ALL DEBRIS RESULTING FROM CONSTRUCTION.

6. THE CONTRACTOR SHALL AT ALL TIMES DURING THE PROGRESS OF THE WORK REMOVE ALL CONSTRUCTION DEBRIS AND MAINTAIN A DUST FREE ENVIRONMENT FOR ALL ADJACENT AREAS.

- FOUNDATION GROUNDING: WHERE FOOTING/FOUNDATION SYSTEMS ON ONE-TWO FAMILY BUILDINGS CONTAIN STEEL REINFORCING, CONFORMANCE TO 527 CMR 12.00 (ELECTRICAL CODE) GROUNDING CRITERIA IS REQUIRED. (8502.1)

- EGRESS DOORS: NO KEYED LOCKS PERMITTED ON INTERIOR OF EGRESS DOORS (5311.4.4)

13. ALL FINISHED WORK SHALL BE FREE OF DEFECTS. THE OWNER RESERVES THE RIGHT TO REJECT ANY MATERIALS AND WORKMANSHIP WHICH ARE NOT CONSIDERED TO BE AT THE HIGHEST STANDARDS OF THE VARIOUS TRADES INVOLVED.

- STAIRWAY MAXIMUM RISE 8 1/4" MINIMUM RUN 9" (5311.5.3.1) OPEN RISERS ARE PERMITED PROVIDED THAT OPENING DOES NOT EXCEED 5" (5311.5.3.3) - HEADERS: APPROPRIATE SIZE FOR FRAMING (TABLE 5502.5(1)(2) (5603.6)(1)(2)(3) MOST HEADERS REQUIRE DBLE JACK STUDS.

14. NO CHANGES OR SUBSTITIONS ARE ALLOWED UNLESS APPROVED BY THE OWNER.

- DESIGN & CONSTRUCTION OF WOOD WALLS: SHALL BE DESIGNED & CONSTRUCTED IN ACCORDANCE WITH 780 CMR 56.00 AND 780 CMR FIGURES 5602.3.1(1) & 5602.3.(2).

15. ALL DATA OUTLETS MUST BE ON A DEDICATED, ISOLATED CIRCUIT. 7. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND VERIFY THAT ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF ALL MATERIALS BY ALL TRADES IS PROPERLY EXECUTED.

- PROTECTION AGAINST DAMAGE: PIPES & (WIRES) SHALL BE PROTECTED BY SHIELD PLATES. (7602.2.1)

16. THE MECHANICAL PORTION OF THIS PROJECT ISSUE AS A DESIGN BUILD PACKAGE. THE GENERAL CONTRACT IS TO SUBMITT TO THE ARCHITECT FOR APPROVAL A SET OF STAMPED MECHANICAL DRAWINGS OUTLINING THE PROPOSED SLOPE OF WORK.

- SAFETY GLAZING INGRESS & EGRESS DOORS REQUIRED & WITHIN 24 INCHES OF DOORS. (5308.4.6) OTHER NEW HAZARDOUS LOCATIONS: STAIRWAYS, RAMPS, LANDINGS, ETC. (5308.4) - BATHROOM VENTILATION REQUIRED & VENTED DIRECT TO OUTSIDE (5303.3)

8. THE CONTRACTOR SHALL UTILIZE THE AREAS WITHIN THE SCOPE OF WORK FOR STORAGE OF MATERIALS AND TOOLS.

- ATTIC ACCESS REQUIRED MINIMUM 22" X 30" FOR 30 SQ. FT.+ AND HEIGHT OF 30"+ (5807.1)

9. ALL WRITEN DIMENSIONS SHALL HAVE PRECEDENCE OVER ALL OTHERS. DO NOT SCALE DRAWINGS. IF THERE IS A QUESTION OR CONFLICT IN DIMENSIONS, NOTIFY THE ARCHITECT FOR CLARIFICATION.

- SOLID BLOCKING REQUIRED IN WALL AT FLOOR LINE, POINTS OF CANTILEVER AND OVER BEARING BEAM (5502.7 & 5502.7.1) - VENTILATION AREA: THE MINIMUM OPENABLE AREA TO THE OUTDOORS SHALL BE 4% OF THE FLOOR AREA BEING VENTILATED. (5303.1)

GRAPHIC SYMBOLS 3 A-3.1

MATERIAL SYMBOLS BLOCKING

BUILDING CROSS SECTION

NEW CONSTRUCTION

CONCRETE

5

102

B

DOOR NUMBER

EARTH ROOM NUMBER

BATT INSULATION WINDOW NUMBER

ELEVATION DESIGNATION

WOOD SECTION REFERENCE

NEW DOOR TO BE INSTALLED

EXISTING DOOR TO REMAIN

PARTITION TYPE

DRYWALL

GENERAL CONTRACTOR GLASS OR GLAZING

P LAM PLYWD

PLASTIC LAMINATE PLYWOOD

W/ WC

WITH

GYPSUM WALL BOARD

PT PR

PRESSURE TREATED PAIR

WD

WOOD

HC

HOLLOW CORE

PT

PAINTED

X-REF

CROSS REFERENCE

HDWR

HARDWARE QT

QUARRY TILE RISER RADIUS

@ AFF ATTEN

AT ABOVE FINISH FLOOR ATTENUATING

GC

BLDG

BUILDING

EXISTING CONSTRUCTION

GRAVEL

5 A-3.3

ABBREVIATIONS GL GWB

CH CL

CEILING HEIGHT CENTER LINE

HM

HOLLOW METAL

HOR

HORIZONTAL

CLR

CLEAR

HT

HEIGHT

COL CONC

COLUMN CONCRETE

HVAC

HEATING, VENT, A/C

R RAD

HWH

HOT WATER HEATER

REQ

REQUIRED

CONT CPT CT

CONTINUOUS CARPET CERAMIC TILE

REFERENCE

INSUL

INSULATION

REF REV

INT

INTERIOR

RH

RIGHT HAND(ED)

RO

ROUGH OPENING ROOF TOP UNIT

DIM DWG(S)

DIMENSION DRAWING(S)

REV #

DATE

ISSUANCE

REVISION(S)

L LAV LH

LENGTH LAVATORY LEFT HAND(ED)

RTU SA SD

SOUND ATTENTION BATTS SMOKE DETECTORS

MAX

MAXIMUM

MECH MFR

MECHANICAL MANUFACTURER

SIM SPEC

SIMILAR SPECIFICATION

SQ

SQUARE

MD MIN

MEDIUM DENSITY MINIMUM

SQ FT

SQUARE FEET

SS

STAINLESS STEEL

OWNERSHIP & USE OF DOCUMENTS

MO MTL

MASONARY OPENING METAL

STL STN

STEEL STAIN

SV

SHEET VINYL

These drawings and specifications are the property and copyright of McKay Architects and shall not be used in whole or in part, or shall be assigned to a third party without the express written permission of McKay Architects. Contractor to verify all information and dimensions in the field prior to start of construction and is to notify McKay Architects of any discrepancies

EA

EACH

EIFS ELEC

EXT INSUL. FINISH SYSTEM ELECTRICAL

ELEV EQ

ELEVATION EQUAL

EWC

ELECTRICAL WATER COOLER

EXT

EXTERIOR

FC

FIRE CODE / FIRE CORE

FD

FLOOR DRAIN

NIC

NOT IN CONTRACT

FEC

FIRE EXTINGUISHER CABINET

TREAD

FINISHED FLOOR FINISHED FLOOR ELEVATION

NIGHT LIGHT NOMINAL

T

FF FFE

NL NOM

THK

THICKNESS

NTS

NOT TO SCALE

TP

TOILET PAPER DISPENSER

FIN

FINISH

TYP

TYPICAL

FFL

FLUORESENT LIGHTING

FOF FOC

FACE OF FINISH FACE OF CONCRETE

UNO

UNLESS NOTED OTHERWISE

FOS

FACE OF STUD

VCT

VINYL COMPOSITION TILE

FRT

FIRE RETARDANT TREATED

VIF

VERIFY IN FIELD

VTR

VENT THROUGH ROOF

TILE

WATER CLOSET

OC OD

ON CENTER OUTSIDE DIAMETER

OH

OPPOSITE HANDED

Title Sheet JOB NO 0052 DATE

DWG BY CKD BY SCALE

MLM

T-1.1