Conefitslimkatalogusangol

Page 1

IMPLANT SYSTEM


CONEFIT SLIM

The Company

info@bionika.hu

BIONIKA Medline Medical Engineering Ltd. was formed in 1989. We have more than 20 years of experience in developing, manufacturing and sales of surgical instruments and implants. BIONIKA is present in the technical fields of odontology, oral surgery, traumatology, orthopaedics and rehabilitation as a company dealing with research and development as well as manufacturing and distribution. According to our aim and conception we attach great significance to the word „BIONIKA� that represents a scientific way of thinking along the common borderlines of biology, technology and electronics, which combines these three fields during our work of research and development.

Clinical and technological experiences: Continuous process, combination and utilisation of the clinical and technological experiences in development contribute to our success, with a feedback throughout the manufacturing base. The most adequate solutions and constructions satisfying the customer demands are born here and they are continuously developed. Development: Owners of BIONIKA attach great importance on continuous product and technological development. Our products are developed by close co-operation of doctors and engineers, fact by which we can assure the highest quality available worldwide and practical efficiency at the same time. Quality: The design, manufacturing and quality management performed according to the adopted measures of the European Union assure the quality expected by our Customers. The BIONIKA Medline Ltd. works according to the EN ISO 9001 and ISO 13485 quality management systems. Our products are marked with the CE sign. Warranty: Following the implantation process, we provide warranty for replacing the unit within one year counting from the date of purchase, regardless of the causal relevance. BIONIKA assumes the risk of ossification process. Otherwise we provide a 5-year long-term warranty for our products. +36 20 9583 629

www.bionika.hu


Due to its characteristic features, the CONEFIT Slim Implant System is one of the best solutions not only for the average tough, but for softer bone structures as well. The operation can be carried out with little exposing or even in transgingival way, complying with the minimal invasive requirements. For the same reasons, the construction is most optimal for prompt loadability. Characteristic constructional and application features: • Tapered self-compressing thread • Cycloid thread profile • High thread pitch • Large depth of thread • One Pic operation technique • Prompt loadability following the recovery of the soft sections • OT-CAP micro compatible snap head • Geometry following the natural tooth root

1,5

info@bionika.hu

+36 20 9583 629

CONEFIT SLIM

CONEFIT Slim Implant System

www.bionika.hu


CONEFIT Slim Implant System parameters

CONEFIT SLIM

CLASSIC

info@bionika.hu

Diameter D (mm)

Length L (mm) 10

12

15

18

ø3 ø 3,5 ø4 ø5

AESTHETIC Diameter D (mm)

Length L (mm) 10

12

15

18

ø3 ø 3,5 ø4 ø5

BALL ABUTMENT (OT-CAP) Diameter D (mm)

Length L (mm) 10

12

15

18

ø3 ø 3,5 ø4 ø5

+36 20 9583 629

www.bionika.hu


CONEFIT Slim Classic Implant System parameters

ø 3,0

Length (L) D

L

10 mm

SL 54.01.30.010

12 mm

SL 54.01.30.012

15 mm

SL 54.01.30.015

Diameter (D)

ø 3,5

Length (L) D

L

10 mm

SL 54.01.35.010

12 mm

SL 54.01.35.012

15 mm

SL 54.01.35.015

Diameter (D)

ø 4,0

Length (L) D

L

10 mm

SL 54.01.40.010

12 mm

SL 54.01.40.012

15 mm

SL 54.01.40.015

18 mm

SL 54.01.40.018

Diameter (D)

ø 5,0

Length (L) D

L

info@bionika.hu

10 mm

SL 54.01.50.010

12 mm

SL 54.01.50.012

15 mm

SL 54.01.50.015

18 mm

SL 54.01.50.018

+36 20 9583 629

CONEFIT SLIM

Diameter (D)

www.bionika.hu


CONEFIT Slim Aesthetic Implant System parameters

CONEFIT SLIM

Diameter (D)

info@bionika.hu

ø 3,0

Length (L) D

L

10 mm

SL 54.03.30.010

12 mm

SL 54.03.30.012

15 mm

SL 54.03.30.015

Diameter (D)

ø 3,5

Length (L)

D

L

10 mm

SL 54.03.35.010

12 mm

SL 54.03.35.012

15 mm

SL 54.03.35.015

Diameter (D)

ø 4,0

Length (L)

D

L

10 mm

SL 54.03.40.010

12 mm

SL 54.03.40.012

15 mm

SL 54.03.40.015

18 mm

SL 54.03.40.018

Diameter (D)

ø 5,0

Length (L)

D

L

10 mm

SL 54.03.50.010

12 mm

SL 54.03.50.012

15 mm

SL 54.03.50.015

18 mm

SL 54.03.50.018

+36 20 9583 629

www.bionika.hu


CONEFIT Slim Ball Implant System parameters

Length (L)

D

L

10 mm

SL 54.02.30.010

12 mm

SL 54.02.30.012

15 mm

SL 54.02.30.015

Diameter (D)

ø 3,5

Length (L)

D

L

10 mm

SL 54.02.35.010

12 mm

SL 54.02.35.012

15 mm

SL 54.02.35.015

Diameter (D)

ø 4,0

Length (L)

D

L

10 mm

SL 54.02.40.010

12 mm

SL 54.02.40.012

15 mm

SL 54.02.40.015

18 mm

SL 54.02.40.018

Diameter (D)

ø 5,0

Length (L)

D

L

info@bionika.hu

ø 3,0

10 mm

SL 54.02.50.010

12 mm

SL 54.02.50.012

15 mm

SL 54.02.50.015

18 mm

SL 54.02.50.018

+36 20 9583 629

CONEFIT SLIM

Diameter (D)

www.bionika.hu


CONEFIT SLIM

Abutments of the Classic Implant System

info@bionika.hu

When choosing the abutment, special attention needs to be paid to the shape of the implant head.

5

1

2

4

3

Type

Typical size (mm) S Sulkus height 2

4

F Abutment height 7

9

1 Anathomic abutment, straight 2 Anathomic abutment, angulated 15째 3 Trapeze abutment 4 Implant Analog 5 Direct Impression coping

+36 20 9583 629

www.bionika.hu


Sulkus height (S)

S

L

L

L

S

Implant Analog

SL 54.01.07.002

SL 54.01.07.004

9 mm

SL 54.01.09.002

SL 54.01.09.004

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.01.07.152

SL 54.01.07.154

9 mm

SL 54.01.09.152

SL 54.01.09.154

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.01.07.012

SL 54.01.07.014

9 mm

SL 54.01.09.012

SL 54.01.09.014

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.01.07.022

SL 54.01.07.024

9 mm

SL 54.01.09.022

SL 54.01.09.024

Abutment height (L)

S

Trapeze abutment

7 mm

Abutment height (L)

S

Direct Impression coping

4 mm

Abutment height (L)

L

Anathomic abutment, angulated 15째

2 mm

Abutment height (L)

Height (L) 11 mm

L

info@bionika.hu

+36 20 9583 629

SL 54.01.00.011

CONEFIT SLIM

Anathomic abutment, straight

www.bionika.hu


CONEFIT SLIM

Abutments of the Aesthetic Implant System

info@bionika.hu

When choosing the abutment, special attention needs to be paid to the shape of the implant head.

5

1

2

4

3

Type

Typical size (mm) S Sulkus height 2

4

F Abutment height 7

9

1 Anathomic abutment, straight 2 Anathomic abutment, angulated 15째 3 Trapeze abutment 4 Implant Analog 5 Direct Impression coping

+36 20 9583 629

www.bionika.hu


Sulkus height (S)

L

L

L

S

Implant Analog

SL 54.03.07.002

SL 54.03.07.004

9 mm

SL 54.03.09.002

SL 54.03.09.004

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.03.07.152

SL 54.03.07.154

9 mm

SL 54.03.09.152

SL 54.03.09.154

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.03.07.012

SL 54.03.07.014

9 mm

SL 54.03.09.012

SL 54.03.09.014

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.03.07.022

SL 54.03.07.024

9 mm

SL 54.03.09.022

SL 54.03.09.024

Abutment height (L)

S

Trapeze abutment

7 mm

Abutment height (L)

S

Direct Impression coping

4 mm

Abutment height (L)

L

S

Anathomic abutment, angulated 15째

2 mm

Abutment height (L)

Height (L) 11 mm

L

info@bionika.hu

+36 20 9583 629

SL 54.03.00.011

CONEFIT SLIM

Anathomic abutment, straight

www.bionika.hu


CONEFIT SLIM

Abutments of the Ball Head Implant System

info@bionika.hu

The basic function of the CONEFIT Slim Implant System is fastening removable prostheses by snap abutments. According to this, we brought the 1 OT-CAP MICRO Head (1.8 mm diameter) and the NORMAL type Head (2.5 mm diameter) into service. The Heads 2 and 3 make the implant usable for holding a glued prosthesis as well.

1.1 1.2

1

5

4

3

2

Type

Typical size (mm) S Sulkus height 2

4

F Abutment height 7

9

1.1 OT-CAP micro metal housing 1.2 OT-CAP micro nylon liner 2 Anathomic abutment, straight 3 Anathomic abutment, angulated 15째 5 Implant Analog

+36 20 9583 629

www.bionika.hu


L

Metal housing (OT-CAP micro)

L

Anathomic abutment, straight

Height (L) 2,5 mm

Height (L) 3 mm

Sulkus height (S) L

S

Anathomic abutment, angulated 15째

L

S

Implant Analog

SL 54.02.00.003

2 mm

4 mm

7 mm

SL 54.02.07.002

SL 54.02.07.004

9 mm

SL 54.02.09.002

SL 54.02.09.004

Sulkus height (S)

2 mm

4 mm

7 mm

SL 54.02.07.152

SL 54.02.07.154

9 mm

SL 54.02.09.152

SL 54.02.09.154

Abutment height (L)

Abutment height (L)

Height (L) 11 mm

L

info@bionika.hu

SL 54.02.00.025

CONEFIT SLIM

Nylon liner (OT-CAP micro)

+36 20 9583 629

SL 54.02.00.011

www.bionika.hu


Surgical Instruments

CONEFIT SLIM

1

info@bionika.hu

2

3

4

5

6

8

7

9

10

11

12

14

15

Designation

13

Size

1

Spear-head drill (initial bur)

3Lt x12/27mm

2

Puncher

D 1,5x10/25mm

3

Drill, short

D 1,1x10/25mm

4

Drill, short

D 1,1x10/25mm

5

Drill, short

D 1,1x10/25mm

6

Drill, long

D 1,2x15/30mm

7

Countersink bit

8

Implantdriver for handpiece, short

4Lt 1,9x10/25mm

9

Implantdriver for handpiece, long

4Lt 1,9x15/30mm

10

Manual driver T-wrench

4Lt 1,9x20/18mm

11

Driving rod for T-wrench

70mm

12

Ratchet wrench

90mm

13

Torque wrench driving adapter, finned, long

4Lt 1,9x21/28mm

14

Torque wrench driving adapter, finned, medium

4Lt 1,9x14/21mm

15

Torque wrench driving adapter, finned, short

D 1,6x7/21mm

+36 20 9583 629

4Lt 1,9x7/14mm www.bionika.hu


10

13

4

14

5

15

6

8

7

1

9

2

12

11

info@bionika.hu

+36 20 9583 629

CONEFIT SLIM

3

www.bionika.hu



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.