Nanoplantleporelloangol

Page 1

an

n

NANOPLANT Implant System abutments

Surgical Instruments 1

2

3

4

5

6

7

8

10

9

4.1 1.1

11

4.2

1.2

12 15

14

13

Designation

1

2

3

4

Type

Size (mm) S Sulkus height

F Abutment height

Size

1

Spear-head drill (initial bur)

3Lt x12/27mm

2

Puncher

D 1,5x10/25mm

3

Drill, short

D 1,1x10/25mm

4

Drill, short

D 1,1x10/25mm

5

Drill, short

D 1,1x10/25mm

6

Drill, long

D 1,2x15/30mm

7

Countersink bit

8

Implantdriver for handpiece, short

D 1,6x7/21mm 4Lt 1,9x10/25mm

9

Implantdriver for handpiece, long

4Lt 1,9x15/30mm

10

Manual driver T-wrench

4Lt 1,9x20/18mm

1.1 Metal housing (OT-CAP micro)

11

Driving rod for T-wrench

70mm

1.2 Nylon liner (OT-CAP micro)

12

Ratchet wrench

90mm

13

Torque wrench driving adapter, finned, long

4Lt 1,9x21/28mm

14

Torque wrench driving adapter, finned, medium

4Lt 1,9x14/21mm

15

Torque wrench driving adapter, finned, short

2

4

2 Anathomic abutment, straight 3 Anathomic abutment, angulated

7

9

4Lt 1,9x7/14mm

Bionika Medline Medicaltechnics Ltd. +36 20 9583 629

o

plant

The main function of the Nano Implant System through removable prostheses, mounted with snap structure. According to this, we used the 1 OT-CAP micro head as standard for basic abutments. Heads 2 and 3 make the implant suitable for holding a glued prosthesis as well.

H-3516 Miskolc, TĂŠgla str. 29. Phone: +36 46 562 406, +36 20 9583 629 Fax: +36 46 652 407 www.bionika.hu

www.bionika.hu


NANOPLANT Implant Sytem

The Company BIONIKA Medline Medical Engineering Ltd. was formed in 1989. We have more than 20 years of experience in developing, manufacturing and sales of surgical instruments and implants. BIONIKA is present in the technical fields of odontology, oral surgery, traumatology, orthopaedics and rehabilitation as a company dealing with research and development as well as manufacturing and distribution. According to our aim and conception we attach great significance to the word „BIONIKA” that represents a scientific way of thinking along the common borderlines of biology, technology and electronics, which combines these three fields during our work of research and development.

Dimension range of ball head implants for removable teeth prostheses

The Nanoplant Implant System can be applied in case of tougher and thinner bone structure than the usual, both for removable and glued teeth prostheses. Characteristic constructional and application properties: • • • • • • •

Minimal invasive intervention – transgingival surgical technique OT-CAP micro compatible snap head Hybrid abutment system Possibility of screw selection according to the sulkus height Geometry aligning to the natural tooth root Self-compressing, self-cutting and self-locking tapered thread form Cycloid round thread gradually deepening and getting sharper on one third of the screw-bolt, resisting best to dynamic force effects • Use the MD type screw-bolts in case of a tougher mandible bone structure, while the MX type is advised in case of softer maxilla • Great primer stability – prompt loadability, above 35 Ncm • Bauer-type compatibility

MD

MX

length L (mm)

diameter D (mm)

9

REHABILITATION - ACCESSIBILITY

TRAUMATOLOGIE - ORTHOPAEDICS

DENTISTRY - OPERATIVE DENTISTRY

0,6

1,0

11

13

15

2

17 D

ø 1,8

L

ø 2,3 ø 2,8

MX

MD

Sulkus height: 4mm

length L (mm)

diameter D (mm)

9 Clinical and technological experiences: Continuous process, combination and utilisation of the clinical and technological experiences in development contribute to our success, with a feedback throughout the manufacturing base. The most adequate solutions and constructions satisfying the customer demands are born here and they are continuously developed.

MX

MD

Sulkus height: 2mm

11

13

15

4

17 D

ø 1,8

L

ø 2,3 ø 2,8

Development: Owners of BIONIKA attach great importance on continuous product and technological development. Our products are developed by close co-operation of doctors and engineers, fact by which we can assure the highest quality available worldwide and practical efficiency at the same time.

Dimension range of conical head implants for glued teeth prostheses

Quality: The design, manufacturing and quality management performed according to the adopted measures of the European Union assure the quality expected by our Customers. The BIONIKA Medline Ltd. works according to the EN ISO 9001 and ISO 13485 quality management systems. Our products are marked with the CE sign.

MX

MD

Sulkus height: 2mm

length L (mm)

diameter D (mm)

9

11

13

15

17

2

ø 1,8

Warranty: Following the implantation process, we provide warranty for replacing the unit within one year counting from the date of purchase, regardless of the causal relevance. BIONIKA assumes the risk of ossification process. Otherwise we provide a 5-year long-term warranty for our products.

ø 2,3

D

ø 2,8

INNOVATE

+36 20 9583 629

+36 20 9583 629

PRODUCTING

info@bionika.hu

info@bionika.hu

TRADE

www.bionika.hu

www.bionika.hu

L