Product description
zehnder charleston Description Zehnder Charleston is a tube-type, sectional, steel radiator. The radiator collectors are made of 1.5 mm thick steel sheet. Tube diameter – 25 mm; Tube wall thickness – 1.25 mm; individual sections (section depth – 46 mm) are welded to form a complete radiator; the radiator is primed, coated with powder enamel of RAL 9016 colour, and are improved following the requirements of DIN 55900. The heat capacity is tested in accordance with DIN EN 442 standard. The radiator complies with the requirements of the GUV (German Accident Insurance). The radiator also complies with the stringent hygienic requirements and is recommended for use in medical institutions.
The radiator is supplied in an installation-ready package; leteral connection (female thread) 4 x 1/2“; by request: • other connection codes, • a desired mounting set, • other colour choice from 700-colour palette of RAL and NCS S; • zinc-plated finish • special shapes, • high-pressure design, up to 18 bar (24 bar test) The picture shows the 2-column model Advantages • classical elegance • safety • optimal matching to required heat capacity • simple cleaning (for example, with the special Zehnder brush made • of sheep’s wool) • hygiene certificate • wide range of models • possible curved and angled design • withstands high pressure • suited for low water flow rates • design including a reflective cover plate • other connection modes • additional application possibilities based upon the wide range of • available accessories
Shipping limitations for deliveries from the factory Model
2-column 3-column 4-column 5-column 6-column
Maximum length at nominal height from 190 to 900 mm > 900 to 3000 mm Number of Length Number of Length sections mm sections mm
64 64 64 55 46
2944 2944 2944 2530 2116
20 20 20 17 14
920 920 920 782 644
Radiators that exceed the above stated maximum limits are delivered in individual blocks. They shall be assembled with the use of nipples by the installer. Suitable nipples (1“ for 2-column models and 5/4“ for models with 3 to 6 columns) are supplied at no charge, together with the radiator.
2
Technical parameters length height depth radiator with 2 to 4 tubes radiator with 5 to 6 tubes Operating temperature
from 184 to 2208 mm from 190 to 3000 mm from 62 to 210 mm max. 12 bar (test 15.6 bar) max. 10 bar (test pressure 13.0 bar) max. 120°
Standard equipment • radiator, primed and finished with powder enamel of • RAL 9016 colour • side connection (female thread) 4 x 1/2“ • 1 plug 1/2“ + 1 air vent 1/2“ • the radiator is fully wrapped with heat-shrink film and placed in a • cardboard box
Standard connection modes From 2 to 4 side connections for the supply and returns and for the air vent and water drain, measuring 3/8“, 1/2“, 3/4“ and 1“ (1“ only for radiators with 3 to 6 columns). Radiators with 3 to 6 columns have 11/4“ left-hand thread on one side and right-hand on the other; radiators with 2 columns have the same 1“ threads. If connections are made from the same side, both the supply and the returns will have right-hand threads; with opposite-side connections, the flow has right-hand thread and the return – left-hand. Other connection codes, including bottom connections, are available upon request. Details provided by request.
Product description
zehnder charleston completto Description Zehnder Charleston Completto is a tube-type, sectional, steel radiator. The radiator collectors are made of 1.5 mm thick steel sheet. Tube diameter – 25 mm; Tube wall thickness – 1.25 mm; individual sections (section depth – 46 mm) are welded to form a complete radiator; the radiator is primed, coated with powder enamel of RAL 9016 colour, and are improved following the requirements of DIN 55900. The heat capacity is tested in accordance with DIN EN 442 standard. The radiator complies with the requirements of the GUV (German Accident Insurance). The radiator also complies with the stringent hygienic requirements and is recommended for use in medical institutions. The radiator is equipped with a built-in AV 6 (Oventrop) thermal valve in its upper side section and a Zehnder thermostat; connection size is M 30 x 1.5 mm;
Connections: 2 x 1/2“ (female thread) in the lower part of the radiator with 50 mm inter-axial distance; the flow goes through the first section, the return – through the second. The radiator is supplied in an installation-ready package; by request: • bottom middle connection, • valve head in the lower connection nipple, • a desired mounting set, • other colour choice from 700-colour palette of RAL and NCS S; • design including a reflective cover plate, • special shapes, • precision adjustment valve, • outside thread size 2 x 3/4”; • Zehnder thermostat
The picture shows the 2-column model. Additional advantages • radiator with thermal valve ready for installation • can use any suitable thermostat M 30 x 1.5 mm • special design possible • pre-installed AV 6 (Oventrop) valve
Shipping limitations for deliveries from the factory Model
2-column 3-column 4-column 5-column 6-column
Maximum length at nominal height from 190 to 900 mm > 900 to 3000 mm Number of Length Number of Length sections mm sections mm
64 64 64 55 46
2944 2944 2944 2530 2116
20 20 20 17 14
Technical parameters length height depth Operating pressure Operating temperature
from 184 to 2208 mm from 190 to 3000 mm from 62 to 210 mm max. 10 bar (Test pressure 13.0 bar) max. 120°
920 920 920 782 644
Minimum length 138 mm (3 sections). Maximum recommended water flow rate 250 kg/hr Radiators that exceed the above stated maximum limits are delivered in individual blocks. They shall be assembled with the use of nipples by the installer. Suitable nipples (1“ for 2-column models and 5/4“ for models with 3 to 6 columns) are supplied at no charge, together with the radiator.
3
Product description
zehnder charleston exchange Description Zehnder Charleston Austausch is a sectional, steel column radiator; the radiator collectors are made of 1.5 mm thick steel sheet, tube diameter – 25 mm, wall thickness – 1.25 mm; individual sections 46 mm long are welded to form a complete radiator; the radiator is primed, coated with powder enamel of RAL 9016 colour, and are improved following the requirements of DIN 55900. With inter-axial distance suitable for exchange or cast iron radiators The heat capacity is tested in accordance with DIN EN 442 standard. The radiator complies with the requirements of the GUV (German Accident Insurance). The radiator also complies with the stringent hygienic requirements and is recommended for use in medical institutions.
The radiator is supplied in an installation-ready package; side connection (female thread) 4 x 1/2“; by request: • a desired mounting set, • different colour; • zinc-plated finish, • design including a reflective cover plate, • special shapes, • high-pressure design (max. 18 bar) The picture shows the 2-column model. Special advantages Zehnder Charleston Austausch radiators have been specially designed for use as replacements for DIN and cast iron radiators. • radiator replacement without modifications to connecting pipes • installation dimensions match existing dimensions • optimal matching to required heat capacity • quick remodeling yields a happy customer • complies with the requirements of the European insurance • association. • simple cleaning (with the special Zehnder brush made • of lamb’s wool)
Shipping limitations for deliveries from the factory Model
2-column 3-column 4-column 5-column 6-column
Maximum length at nominal height from 190 to 900 mm > 900 to 3000 mm Number of Length Number of Length sections mm sections mm
64 64 64 55 46
2944 2944 2944 2530 2116
20 20 20 17 14
920 920 920 782 644
Radiators that exceed the above stated maximum limits are delivered in individual blocks. They shall be assembled with the use of nipples by the installer. Suitable nipples (1“ for 2-column models and 5/4“ for models with 3 to 6 columns) are supplied at no charge, together with the radiator.
4
Model Number of sections Installation height Installation depth Connection code Mounting Set Operating pressure Operating temperature
..................... .............. mm .............. mm ..................... ..................... max. 10 bar max. 120°
Standard equipment • radiator, primed and finished with powder enamel • of RAL 9016 colour • side connection (female thread) 4 x 1/2“ • 1 plug 1/2“ + 1 air vent 1/2“ • the radiator is fully wrapped with heat-shrink film and placed • in a cardboard box
Standard connection codes From 2 to 4 side connections for the supply and returns and for the air vent and water drain, measuring 3/8”, 1/2”, 3/4“ and 1“ (1“ only for radiators with 3 to 6 columns) Radiators with 3 to 6 columns have 11/4“ left-hand thread on one side and right-hand on the other; radiators with 2 columns have the same kind 1“ threads. If connections are made from the same side, both the supply and the returns will have right-hand threads; with opposite-side connections, the flow has right-hand thread and the return – left-hand. By request, the unit can be delivered with bottom connection in the middle of the radiator, on its front side or on the wall-facing side. Details provided on request.
zehnder Notes
5
Product description
zehnder charleston relax
Description Zehnder Charleston Relax is a tube-type radiator. Precision vertical tubes are fully welded to the radiator heads. The radiator collectors are made of 1.5 mm thick steel sheet, large tubes are made of steel; tube diameter – 25 mm. The heat capacity is tested in accordance with DIN EN 442 standard. Doubled-up connecting section with built-in valve in the upper nipple; bottom connection of supply and returns. Tube-type Zehnder radiator complies with the stringent hygienic requirements and is recommended for use in medical institutions. The bench is made of all-veneer plywood, finished in lacquer with a silky sheen. The radiator is primed, coated with powder enamel, and improved in accordance with DIN 55900.
length height depth Operating pressure Operating temperature
6
598 or 828 mm 455 mm 173 mm max. 10 bar (test pressure 13.0 bar) max. 120°
Advantages • ideally suited for the foyer, child’s bedroom, hobby room, • or winter garden • additional seating area • stand • attracts attention
Standard equipment • radiator primed and finished with powder enamel of RAL 9016 • colour • bottom, same-side 2 x 1/2” connection with 50 mm connection • spacing; flow - outside, return - inside. • built-in valve in the upper nipple, elbow adapter for thermostat • with M 30 x 1.5 mm thread • welded-on feet • bench made of all-veneer plywood, finished in lacquer with • a silky sheen
Technical data
zehnder charleston relax Lacquered finish Model
Overall
Overall
Radiator
Radiator
height
depth
length
depth
Heat capacity at system temperature
Water content
75/65/20°C
CR 5026-13 CR 5026-18
Exponent
70/55/20°C
55/45/20°C
70/55/24
55/45/24
Weight Normal water without
flow rate
water
mm
mm
mm
mm
W
W
W
n
l
kg
kg/hr
455 455
260 260
598 828
173 173
539 696
436/384 563/496
283/235 365/304
1,25 1,25
10,40 14,40
18,60 25,10
46,34 59,84
By request:
Order No.
• different colour • natural wood seat • Zehnder thermostat • white, black, or chrome plated comfort accessories
5600011640 by request 8200819050 8200819058
V = flow (in 1st section) R = return (in 2nd section)
Note: Dimensions in drawing refer to model CR 5026-18.
7
Connection modes
zehnder charleston Standard connections (no additional cost) If the connection method is not specified in the order, the radiator will be supplied with standard, 4 x 1/2� connection. The following standard connection options are possible: V
1/2"
1/2" L
L 1/2"
1/2"
V
R
1/2"
1/2" B
B 1/2"
1/2"
R
1/2"
V
L 1/2"
1/2" L
B 1/2"
1/2"
R
R
1/2"
1/2"
V
1/2" B
Special connection types Zehnder Charleston radiator When placing the order, it is necessary to show the connection number (Nr.) and dimensions same-side
V
3 L
1
L 1
120 R
2
V
1
4
2
L 1
3 L
V
4
R
3
V
No additional cost
320
140 2
L 1
4
R
R
2
3
R
R
1
2
4
3
L
410
230 V
3
340
2
4
E
E
3
L
L 1
V
4
opposite-end 1
V
2
V
1
4
R
R
2
3
R
R
1
2
1
2
4
E
E
3
L
L 1
R 3 L
1
4
2
V
3
443 4
2
4
R
R
V
3
2
Additional cost applies
4
R
R
V
R
V 1
3
R
4
E
E
2
V
V
3
1
4
2
3
1
114
314
134 2
L 1
223 V
R
1
3 L
1
453
V
vertically above
3
L 1
4
V
V
R
253 2
3 4
2
4
V
vertically underneath (the lower 2) with connection spacing 50 mm 3))
V
423
243 2
4
310
130
vertically underneath
3
420
240
R 3
334 4
E
E
2
4
V
vertically top and bottom (flow on top, return on the bottom)
1
1
3
2
4
2
3
327
147
4
R
vertically bottom and top (flow on the bottom, return on top)
L
R 1
R 1
3
3
2
4
1
3 L
E
E
2
4
V
V L 1
23
for monotube valve, vertical 1)
3
43 4
2
4
2
V/R
V/R
for monotube valve, horizontal 1)
3 L
1
V/R
L
417
237
L 1
20 2
3
40 4
2
4
V/R
V = flow, R = return, L = air vent, E = water drain, B = blind plug, O = buffle (standard), • = buffle (100% watertight)
1)
when placing the order, it is necessary to show information about the valve manufacturer, it is possible to use ZehnderVario connection hardware 3) possible only with an even number of sections 2)
8
No additional cost
Connection modes for zehnder charleston completto radiators and special design radiators
zehnder charleston Connection codes - zehnder charleston completto (additional cost applies) 1/2" L
V 1/2"
L 1/2"
V 1/2"
R 1/2"
built-in valve on top, bottom, same-side connection
1/2" L
R 1/2"
built-in valve on the bottom, bottom, same-side connection
1/2" L
V 1/2"
1/2" L
R 1/2"
V 1/2"
built-in valve on top, bottom, middle connection
R 1/2"
built-in valve on top, bottom, opposite-side connection
V = flow, R = return, L = air vent, E = water drain, B = blind plug, O = buffle (standard), • = buffle (100% watertight)
Special designs Description Additional special connections Fully welded construction high-pressure design max. 18 bar (not possible for Completto design) Angled or curved design For an additional cost (calculated upon request).
Radiator design over 3000 mm high Welded-on lifting eyes Extended length radiator, assembled from segments using nipples Zinc-plated construction (see explanation on page 416) Zinc plating with subsequent finishing using enamel of standard colour (RAL 9016)
Insert tube In the event a Zehnder Charleston radiator has same-side connections and the number of its sections exceeds the number indicated below, the radiator may be designed with a factory-installed insert tube that will guarantee achieving the heat capacity ratings shown in the catalog (additional cost applies) 2-column model 3-column model 4-column model 5-column model 6-column model
from 87 sections = installation length 4002 mm from 85 sections = installation length 3910 mm from 81 sections = installation length 3726 mm from 71 sections = installation length 3266 mm from 55 sections = installation length 2530 mm
Insert tube Einsatzrohr
1 3
/
Supply Vorlauf
2 3
/
Return RĂźcklauf
9
Recommended fastener sets for easy installation.
zehnder charleston - zehnder charleston completto The following table shows three different brackets for Zehnder Charleston. The desired mounting set can be ordered by indicating the brackets name (for example, SSK Set) The required number of brackets will be supplied with the radiator. The brackets type determines the distance to the wall and the connection size. This information is included in the table.
Nominal radiator height
SSK Set
CVD Set
BKE Set
300 – 900 mm
260 – 1200 mm
260 – 1200 mm
SSK
on top: BH + CVD on bottom: BH +CVD
on top: BH + BKE on bottom: BH +BKE
Depiction of brackets and support brackets with the radiator (1 vertical mounting line)
Brackets position
Distance to wall WA (from the wall to radiator’s back edge)
A WA
Distance A (from the wall to rear connection centerline) A
A WA
WA
A
2-column model 3-column model 4-column model 5-column model 6-column model 1)
min.100
min.100
min.100
min.100
WA
WA [mm]
A [mm]
WA [mm]
A [mm]
WA [mm]
A [mm]
20 20 20 20 20
51 70 88 107 125
43 43 43 43 43
74 93 111 130 148
35 – 65 35 – 65 35 – 65 35 – 65 35 – 65
66 – 96 85 – 115 103 – 133 122 – 152 140 - 170
Installation recommendation for BH brackets: middle (bolt) 120 mm from the radiator’s upper or lower edge With the radiator height > 1200 mm, CVD and BKE mounting sets are of limited use. With bottom connection, 2) or with bottom side connection, when connecting to plastic pipes or if the radiator weight exceeds 100 kg, 2) we recommend using the TKA fastener set (special order) for installation. 3) To prevent the lifting of the radiator, the BKE fastener set may be used in combination with BFS 1 safety springs (special order) 2)
10
Further recommendations for determining the number of brackets and holders for radiators
zehnder charleston For the number of sections from 4 to 20 from 21 to 40 from 41 to 60 from 61 to 64
For Zehnder Charleston radiators from 190 to 600 mm high on top: -
-
-
-
2
3
4
5
on top: BH/BHK brackets with BKF wall brackets
2
3
4
5
on bottom: BH/BHK brackets with BKF wall brackets
2
3
4
5
on top: BH/BHK brackets with EAK wall brackets
2
3
4
5
on bottom: BH/BHK brackets with EAK wall brackets
2
3
4
5
on top: BH/BHK brackets with AK wall brackets
2
3
4
5
on bottom: BH/BHK brackets with AK wall brackets
2
3
4
5
on top: NA/NAK brackets
2
3
4
5
on bottom: TAK wall brackets
2
3
4
5
on bottom: STF floor mounts, welded-on feet, or HFK adjustable height feet STF + AD
HFK + AD
For Zehnder Charleston radiators from 260 to 1200 mm high
on top
on top
on top
on bottom
on bottom
on bottom
For Zehnder Charleston radiators from 190 to 3000 mm high
on top
on bottom
11
Technical parameters per section
zehnder charleston - zehnder charleston completto zehnder charleston completto Model C 2050-12 N
zehnder charleston Model 2050-12
50
Model
(Nominal)
Effective
connection
(C = Completto)
height,
height,
spacing,
(C) 2019 (C) 3019 (C) 4019 (C) 5019 (C) 6019 (C) 2026 (C) 3026 (C) 4026 (C) 5026 (C) 6026 (C) 2030 (C) 3030 (C) 4030 (C) 5030 (C) 6030 (C) 2035 (C) 3035 (C) 4035 (C) 5035 (C) 6035 (C) 2040 (C) 3040 (C) 4040 (C) 5040 (C) 6040 (C) 2045 (C) 3045 (C) 4045 (C) 5045 (C) 6045 (C) 2050 (C) 3050 (C) 4050 (C) 5050 (C) 6050 (C) 2055 (C) 3055 (C) 4055 (C) 5055 (C) 6055 (C) 2060 (C) 3060 (C) 4060 (C) 5060 (C) 6060 (C) 2075 (C) 3075 (C) 4075 (C) 5075 (C) 6075 (C) 2090 (C) 3090 (C) 4090 (C) 5090 (C) 6090
12
depth
length per
Heat capacity at system temperature
Exponent,
element 90/70/20째C
75/65/20째C
70/55/20째C
55/45/20째C W
mm
mm
mm
mm
mm
W
W
W
190 190 190 190 190 260 260 260 260 260 300 300 300 300 300 350 350 350 350 350 400 400 400 400 400 450 450 450 450 450 500 500 500 500 500 550 550 550 550 550 600 600 600 600 600 750 750 750 750 750 900 900 900 900 900
177 185 200 200 200 260 260 260 260 260 292 300 300 300 300 342 350 350 350 350 392 400 400 400 400 442 450 450 450 450 492 500 500 500 500 542 500 500 500 500 592 600 600 600 600 742 750 750 750 750 892 900 900 900 900
119 119 134 134 134 202 194 194 194 194 234 234 234 234 234 284 284 284 284 284 334 334 334 334 334 384 384 384 384 384 434 434 434 434 434 484 484 484 484 484 534 534 534 534 534 684 684 684 684 684 834 834 834 834 834
62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210
46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46
19 25 35 44 53 26 35 47 57 68 30 40 53 65 77 35 47 62 75 89 39 53 69 86 102 44 59 77 96 113 48 65 86 106 125 53 70 93 114 136 57 77 101 125 147 69 93 122 151 180 81 109 143 177 210
15 20 28 35 42 21 28 37 45 54 24 32 42 52 61 28 37 49 60 71 31 42 55 68 81 35 47 61 76 90 38 52 68 84 99 42 56 74 91 108 45 61 67 80 117 55 74 97 120 143 64 87 114 141 167
12 16 23 28 33 17 23 30 36 43 19 26 34 42 50 22 30 39 48 57 25 34 44 55 65 28 38 50 61 72 31 42 55 67 80 34 45 60 73 87 37 49 64 79 94 44 60 79 96 115 52 70 92 113 134
8 10 15 18 22 11 15 19 24 28 12 17 22 27 32 14 19 25 31 37 16 22 29 35 42 18 25 32 40 47 20 27 35 43 51 22 29 38 47 56 24 32 41 51 60 29 39 51 62 73 33 45 59 72 85
n
1,26 1,27 1,26 1,25 1,27 1,25 1,25 1,25 1,25 1,27 1,24 1,25 1,25 1,25 1,26 1,24 1,25 1,25 1,26 1,26 1,24 1,25 1,26 1,26 1,27 1,24 1,25 1,26 1,26 1,27 1,25 1,25 1,26 1,27 1,28 1,25 1,26 1,26 1,27 1,28 1,25 1,26 1,27 1,27 1,29 1,25 1,26 1,27 1,29 1,30 1,25 1,27 1,28 1,30 1,31
Technical parameters per section
zehnder charleston - zehnder charleston completto zehnder charleston completto Model C 2050-12 N
zehnder charleston Model 2050-12
50
Model
(Nominal)
Effective
connection
(C = Completto)
height,
height,
spacing,
mm
mm
mm
(C) 2019 (C) 3019 (C) 4019 (C) 5019 (C) 6019 (C) 2026 (C) 3026 (C) 4026 (C) 5026 (C) 6026 (C) 2030 (C) 3030 (C) 4030 (C) 5030 (C) 6030 (C) 2035 (C) 3035 (C) 4035 (C) 5035 (C) 6035 (C) 2040 (C) 3040 (C) 4040 (C) 5040 (C) 6040 (C) 2045 (C) 3045 (C) 4045 (C) 5045 (C) 6045 (C) 2050 (C) 3050 (C) 4050 (C) 5050 (C) 6050 (C) 2055 (C) 3055 (C) 4055 (C) 5055 (C) 6055 (C) 2060 (C) 3060 (C) 4060 (C) 5060 (C) 6060 (C) 2075 (C) 3075 (C) 4075 (C) 5075 (C) 6075 (C) 2090 (C) 3090 (C) 4090 (C) 5090 (C) 6090
190 190 190 190 190 260 260 260 260 260 300 300 300 300 300 350 350 350 350 350 400 400 400 400 400 450 450 450 450 450 500 500 500 500 500 550 550 550 550 550 600 600 600 600 600 750 750 750 750 750 900 900 900 900 900
177 185 200 200 200 260 260 260 260 260 292 300 300 300 300 342 350 350 350 350 392 400 400 400 400 442 450 450 450 450 492 500 500 500 500 542 500 500 500 500 592 600 600 600 600 742 750 750 750 750 892 900 900 900 900
119 119 134 134 134 202 194 194 194 194 234 234 234 234 234 284 284 284 284 284 334 334 334 334 334 384 384 384 384 384 434 434 434 434 434 484 484 484 484 484 534 534 534 534 534 684 684 684 684 684 834 834 834 834 834
depth
mm
62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210
Surface
Water
Weight
Radiant
Normal water
area
content,
without water,
heat share,
flow rate,
kg
%
kg/hr
0,30 0,50 0,80 0,90 1,10 0,40 0,60 0,90 1,20 1,40 0,50 0,70 1,00 1,30 1,60 0,60 0,90 1,20 1,50 1,80 0,60 1,00 1,40 1,70 2,00 0,70 1,10 1,50 1,90 2,20 0,80 1,20 1,70 2,10 2,40 0,90 1,30 1,90 2,30 2,70 1,00 1,40 2,00 2,50 2,90 1,20 1,70 2,50 3,10 3,50 1,40 2,10 2,90 3,60 4,20
30 23 20 19 19 25 21 18 17 18 25 20 18 16 15 24 20 17 15 14 25 19 16 15 14 24 19 16 14 13 23 18 16 14 13 23 18 16 14 12 23 18 15 13 12 22 18 15 13 12 22 18 15 13 12
1,00 2,00 2,00 3,00 4,00 2,00 2,00 3,00 4,00 5,00 2,00 3,00 4,00 4,00 5,00 2,00 3,00 4,00 5,00 6,00 3,00 4,00 5,00 6,00 7,00 3,00 4,00 5,00 7,00 8,00 3,00 4,00 6,00 7,00 9,00 4,00 5,00 6,00 8,00 9,00 4,00 5,00 7,00 8,00 10,00 5,00 6,00 8,00 10,00 12,00 5,00 7,00 10,00 12,00 14,00
m2
0,02 0,04 0,06 0,08 0,09 0,04 0,06 0,08 0,10 0,12 0,04 0,07 0,09 0,12 0,14 0,05 0,08 0,11 0,13 0,16 0,06 0,09 0,12 0,15 0,19 0,07 0,10 0,14 0,17 0,21 0,07 0,11 0,15 0,19 0,23 0,08 0,12 0,17 0,21 0,26 0,09 0,14 0,19 0,23 0,28 0,11 0,17 0,23 0,29 0,35 0,14 0,21 0,28 0,35 0,42
l
0,30 0,40 0,60 0,70 0,80 0,30 0,50 0,70 0,80 1,00 0,40 0,60 0,70 0,90 1,10 0,40 0,60 0,80 1,00 1,20 0,40 0,70 0,90 1,10 1,30 0,50 0,70 1,00 1,20 1,40 0,50 0,80 1,00 1,30 1,50 0,60 0,90 1,10 1,40 1,60 0,60 0,90 1,20 1,50 1,80 0,70 1,10 1,40 1,80 2,10 0,80 1,30 1,70 2,10 2,50
13
Technical parameters per section
zehnder charleston - zehnder charleston completto zehnder charleston completto Model C 2100-12 N
zehnder charleston Model 2100-12
50
Model
(Nominal)
Effective
connection
(C = Completto)
height,
height,
spacing,
(C) 2100 (C) 3100 (C) 4100 (C) 5100 (C) 6100 (C) 2110 (C) 3110 (C) 4110 (C) 5110 (C) 6110 (C) 2120 (C) 3120 (C) 4120 (C) 5120 (C) 6120 (C) 2150 (C) 3150 (C) 4150 (C) 5150 (C) 6150 (C) 2180 (C) 3180 (C) 4180 (C) 5180 (C) 6180 (C) 2200 (C) 3200 (C) 4200 (C) 5200 (C) 6200 (C) 2220 (C) 3220 (C) 4220 (C) 5220 (C) 6220 (C) 2250 (C) 3250 (C) 4250 (C) 5250 (C) 6250 (C) 2280 (C) 3280 (C) 4280 (C) 5280 (C) 6280 (C) 2300 (C) 3300 (C) 4300 (C) 5300 (C) 6300
14
depth
length per
Heat capacity at system temperature
Exponent,
element 90/70/20째C
75/65/20째C
70/55/20째C
55/45/20째C
mm
mm
mm
mm
mm
W
W
W
W
1000 1000 1000 1000 1000 1100 1100 1100 1100 1100 1200 1200 1200 1200 1200 1500 1500 1500 1500 1500 1800 1800 1800 1800 1800 2000 2000 2000 2000 2000 2200 2200 2200 2200 2200 2500 2500 2500 2500 2500 2800 2800 2800 2800 2800 3000 3000 3000 3000 3000
992 1000 1000 1000 1000 1092 1100 1100 1100 1100 1192 1200 1200 1200 1200 1492 1500 1500 1500 1500 1792 1800 1800 1800 1800 1992 2000 2000 2000 2000 2192 2200 2200 2200 2200 2492 2500 2500 2500 2500 2792 2800 2800 2800 2800 2992 3000 3000 3000 3000
934 934 934 934 934 1034 1034 1034 1034 1034 1134 1134 1134 1134 1134 1434 1434 1434 1434 1434 1734 1734 1734 1734 1734 1934 1934 1934 1934 1934 2134 2134 2134 2134 2134 2434 2434 2434 2434 2434 2734 2734 2734 2734 2734 2934 2934 2934 2934 2934
62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210
46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46
88 120 157 194 230 94 130 170 210 249 104 145 185 225 264 131 176 226 276 322 156 209 268 326 381 174 230 294 359 420 190 252 322 392 459 215 283 364 443 518 238 316 406 493 577 253 338 434 528 618
70 95 125 154 183 75 103 135 167 198 83 115 147 179 210 104 140 180 219 256 124 166 213 259 303 138 183 234 285 334 151 200 256 312 365 171 225 289 352 412 189 251 323 392 459 201 269 345 420 491
56 77 100 124 147 60 83 108 134 158 67 92 118 143 168 84 112 144 175 205 99 132 170 207 242 111 146 187 228 267 121 160 205 149 292 137 180 231 282 329 152 201 259 314 368 161 216 277 337 394
36 49 64 79 93 39 53 69 85 100 43 59 75 91 106 54 71 91 111 129 63 83 107 131 152 70 92 118 144 169 77 101 129 158 185 87 114 147 179 208 97 128 165 200 234 103 137 176 215 251
n
1,25 1,27 1,29 1,30 1,31 1,25 1,28 1,29 1,31 1,32 1,26 1,29 1,30 1,31 1,32 1,28 1,31 1,31 1,32 1,32 1,31 1,33 1,33 1,32 1,33 1,31 1,33 1,32 1,32 1,32 1,31 1,32 1,32 1,32 1,32 1,30 1,32 1,31 1,31 1,32 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30
Technical parameters per section
zehnder charleston - zehnder charleston completto zehnder charleston completto Model C 2100-12 N
zehnder charleston Model 2100-12
50
Model
(Nominal)
Effective
connection
(C = Completto)
height,
height,
spacing,
mm
mm
mm
(C) 2100 (C) 3100 (C) 4100 (C) 5100 (C) 6100 (C) 2110 (C) 3110 (C) 4110 (C) 5110 (C) 6110 (C) 2120 (C) 3120 (C) 4120 (C) 5120 (C) 6120 (C) 2150 (C) 3150 (C) 4150 (C) 5150 (C) 6150 (C) 2180 (C) 3180 (C) 4180 (C) 5180 (C) 6180 (C) 2200 (C) 3200 (C) 4200 (C) 5200 (C) 6200 (C) 2220 (C) 3220 (C) 4220 (C) 5220 (C) 6220 (C) 2250 (C) 3250 (C) 4250 (C) 5250 (C) 6250 (C) 2280 (C) 3280 (C) 4280 (C) 5280 (C) 6280 (C) 2300 (C) 3300 (C) 4300 (C) 5300 (C) 6300
1000 1000 1000 1000 1000 1100 1100 1100 1100 1100 1200 1200 1200 1200 1200 1500 1500 1500 1500 1500 1800 1800 1800 1800 1800 2000 2000 2000 2000 2000 2200 2200 2200 2200 2200 2500 2500 2500 2500 2500 2800 2800 2800 2800 2800 3000 3000 3000 3000 3000
992 1000 1000 1000 1000 1092 1100 1100 1100 1100 1192 1200 1200 1200 1200 1492 1500 1500 1500 1500 1792 1800 1800 1800 1800 1992 2000 2000 2000 2000 2192 2200 2200 2200 2200 2492 2500 2500 2500 2500 2792 2800 2800 2800 2800 2992 3000 3000 3000 3000
934 934 934 934 934 1034 1034 1034 1034 1034 1134 1134 1134 1134 1134 1434 1434 1434 1434 1434 1734 1734 1734 1734 1734 1934 1934 1934 1934 1934 2134 2134 2134 2134 2134 2434 2434 2434 2434 2434 2734 2734 2734 2734 2734 2934 2934 2934 2934 2934
depth
mm
62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210 62 100 136 173 210
Surface
Water
Weight
Radiant
Normal water
area
content,
without water,
heat share,
flow rate,
kg
%
kg/hr
1,60 2,30 3,20 3,90 4,60 1,80 2,50 3,40 4,30 5,10 1,90 2,80 3,70 4,60 5,50 2,30 3,40 4,40 5,60 6,80 2,70 4,10 5,20 6,60 8,20 3,00 4,50 5,80 7,30 9,10 3,30 4,90 6,40 8,10 10,00 3,70 5,50 7,40 9,30 11,30 4,10 6,10 8,30 10,50 12,70 4,40 6,40 8,90 11,30 13,60
22 18 15 13 12 22 18 15 13 12 22 18 15 13 12 23 18 15 13 12 23 18 15 13 12 23 18 15 13 12 23 18 15 13 12 23 18 15 13 12 23 18 15 13 12 23 18 15 13 12
6,00 8,00 11,00 13,00 16,00 6,00 9,00 12,00 14,00 17,00 7,00 10,00 13,00 15,00 18,00 9,00 12,00 15,00 19,00 22,00 11,00 14,00 18,00 22,00 26,00 12,00 16,00 20,00 25,00 29,00 13,00 17,00 22,00 27,00 31,00 15,00 19,00 25,00 30,00 35,00 16,00 22,00 28,00 34,00 39,00 17,00 23,00 30,00 36,00 42,00
m2
0,15 0,23 0,31 0,39 0,47 0,17 0,25 0,34 0,43 0,52 0,18 0,28 0,37 0,47 0,56 0,23 0,35 0,47 0,59 0,70 0,28 0,42 0,56 0,70 0,85 0,31 0,47 0,63 0,78 0,94 0,34 0,51 0,69 0,86 1,03 0,39 0,58 0,78 0,98 1,18 0,44 0,65 0,88 1,10 1,33 0,47 0,70 0,94 1,18 1,41
l
0,90 1,40 1,80 2,30 2,70 1,00 1,50 2,00 2,50 3,00 1,10 1,60 2,10 2,70 3,20 1,30 2,00 2,60 3,30 4,00 1,50 2,40 3,10 3,90 4,70 1,70 2,60 3,40 4,30 5,20 1,90 2,90 3,80 4,70 5,60 2,10 3,20 4,30 5,30 6,30 2,40 3,60 4,80 5,90 7,00 2,50 3,90 5,10 6,40 7,50
15
Technical parameters
zehnder charleston - zehnder charleston exchange 2-column model
3-column model
4-column model
5-column model
6-column model
62
100
136
173
210
N BH
Horizontal connection
46
46
46
46
14
BL
46
46
14
1 46
11/4 55
11/4 55
11/4 55
11/4 55
62
100
136
173
210
21
21 X
L1
BH Y
Vertical, opposite-end connection
31
50
68
86,5
105
Vertical, same-side connection (left or right) 100
136
173
210
136
173
210
21
50
50
21
L1
BH
62
Vertical connection for “monotube” valve (for single-pipe systems), 1/2” 100
69
69
12,5
Total length, including plug = BL + 28 mm BL = length BH = effective height, table value = nominal height minus 8 mm = (for 2-column models) (exception: 190 and 260 mm) = nominal height = (for 3 to 6-column models) (exception: 190 mm) L1 = thread protrusion for connection N = eye-to-eye distance
16
12
BH
62
X = connection dimension in the horizontal direction = BL - 42 mm Y = connection dimension in the vertical direction = BL +2 x L1 Unit of measure: mm Connection size Ø L1 mm
/8”
3
6
/2”
1
6
/4” 15
3
Distance to the wall and distance from the wall to connection centerline depend upon mounting mode and bracket type.
Technical parameters
zehnder charleston - zehnder charleston completto Valve in upper part of the radiator, bottom, same-side connection 2-column model
3-column model
4-column model
5-column model
6-column model
62
100
136
173
210
A
BH
L
14 21
46
14
31
50
68
86,5
105
6
50 BL
Valve in upper part of the radiator, bottom center connection
Valve in upper part of the radiator, bottom, oppositr-end connection A
1/2"L
46
1/2"L
1/2"L
A O
1/2"B 14
46
21
14
50 V R
21
21
BL R
V BL
Valve in lower part of the radiator, bottom, same-side connection
1/2"L
1/2"L
A 1/2"B 14
46
21
14
50 V R
BL
Attention: in this design, the heat capacity of the first section will be lower due to insufficient water circulation.
Total length, including valve and plug = BL + 119 mm BH = effective height, table value = (see starting page 64) = nominal height minus 8 mm = (for 2-column models) (exception: 190 and 260 mm) = nominal height = (for 3 to 6-column models) (exception: 190 mm) BL = length = number of sections x 46 mm A = thermostat protrusion 105 mm V = flow R = return L = air vent B = plug Distance to the wall and distance from the wall to connection centerline depend upon mounting mode and braket type. Technical parameters of the valve Built-in regulator valve OV 1� (for 2-column models) or OV 5/4� (for 3 to 6-column models), installed at the factory. Maximum recommended water flow rate: 250 kg/hr Information on regulator valve – additional.
17
Special design
zehnder charleston angled models B
A
A
B
90
< AB
< AB
inside angle 90°
< AB
< AB
B
90
inside angle from 90° to 179°
B
A
A
outside angle 90°
outside angle from 90° to 179°
B
< AB < AC
C
A
C
B
< BC < AB
A
double inside angle from 90° to 179°
double outside angle from 90° to 179°
Ability to manufacture angled models: from 90° to 179°. When requesting pricing, it is necessary to provide drawings with the following dimensions: dimensions A, B, C and angles · & ‚ in degrees. Templates submitted at order stage cannot be changed. curved models
R
R
inside radius
outside radius
Zehnder Charleston radiators can be produced in curved designs with radius not less than: for 2-column models: for 3-column models: for 4-column models: for 5-column models: for 6-column models:
400 mm 650 mm 750 mm 900 mm 1000 mm
When requesting pricing, it is necessary to provide drawings with the following dimensions: radius R and installation length in mm. Templates submitted at order stage cannot be changed. In curved Zehnder Charleston Completto versions, the first three sections are not curved.
18
Angled design 90째
zehnder charleston 2-column model
3-column model
4-column model
5-column model
6-column model
Normal inside corner
106
143
180
216
254
No. 0 - 87
No. 0 - 89
No. 0 - 92
No. 0 - 96
No. 0 - 100
Normal outside corner
132
170
206
245
280
No. 0 - 88
No. 0 - 90
No. 0 - 93
No. 0 - 97
No. 0 - 101
Inside corner and special outside corner
158
180
216
254
No. 0 - 91
No. 0 - 94
No. 0 - 98
No. 0 - 102
Special outside corner
206
260
280
No. 0 - 95
No. 0 - 99
No. 0 - 104
Special inside corner
270 No. 0 - 189
310 No. 0 - 103
Unit of measure: mm It is necessary to indicate the corner design number when placing the order.
19
Product description
zehnder bank-radiator
The picture shows model B 6150/5 Description Zehnder Bank-Radiator is a tube-type, sectional, steel radiator with 4-6 columns. The radiator collectors are made of 1.5 mm thick steel sheet, tube diameter – 25 mm, wall thickness – 1.25 mm, individual horizontal sections are welded to form a complete radiator. With brackets comprised of bench supports and frames for sub-floor installation, lacquered to match the radiator colour. The seat is selected individually. The radiator is primed, coated with RAL 9016 colour powder enamel, and improved in accordance with DIN 55900. The heat capacity is tested in accordance with DIN EN 442 standard. The radiator complies with the requirements of the GUV (German Accident Insurance). The radiator complies with the stringent hygienic requirements and is recommended for use in medical institutions. The radiator is supplied in an installation-ready package. Bottom, opposite-end connection (female thread) 2 x 1/2”
by request: • other connection codes, • other colour choice from 700-colour palette of RAL and NCS S
length height depth Operating pressure, max: Operating temperature
20
from 1200 to 3000 mm from 469 to 653 mm from 136 to 210 mm 10 bar (Test pressure 13.0 bar) max. 120°
Standard equipment • bottom, opposite-end connection 2 x 1/2” • air vent in the lateral part of the radiator • radiator is primed and finished with powder enamel • of RAL 9016 colour • brackets finished in RAL 9016 colour (without the seat) • air-vent, 1/2” Seat not included in the kit
Advantages • dual function: used as a bench and as a radiator • various seat heights • ability to individually select the seat • ability to turn the radiator to the right or left • simple cleaning (for example, with the special • Zehnder brush made of lamb’s wool) • The radiator complies with the requirements of • the GUV (German Accident Insurance).
Product description
zehnder charleston bank
The picture shows model CB 5026-35 Description Zehnder Charleston Bank is a tube-type, sectional, steel radiator with 4-6 columns and with additional brackets for sub-floor or finished floor installation of the radiator, to be used as a bench. The radiator collectors are made of 1.5 mm thick steel sheet, tube diameter is 25 mm, wall thickness is 1.25 mm, and individual sections are welded together to form the complete radiator. The seat is selected individually. The radiator is primed, coated with RAL 9016 colour powder enamel, and improved in accordance with DIN 55900. The heat capacity is tested in accordance with DIN EN 442 standard. The radiator complies with the requirements of the GUV (German Accident Insurance). The radiator complies with the stringent hygienic requirements and is recommended for use in medical institutions. Bottom, opposite-end connection (female thread) 2 x 1/2” The radiator is supplied in an installation-ready package.
by request: • other connection codes, • Completto design • other colour choice from 700-colour palette of RAL and NCS S • special shapes, • design including a reflective cover plate, • high-pressure design (max. 18 bar)
length height depth Operating pressure, max: Operating temperature
Standard equipment • radiator is primed and finished with powder enamel • of RAL 9016 colour • bottom, opposite-end connection 2 x 1/2” • bench brackets (without seat) • air-vent, 1/2” Seat not included in the kit
Advantages • ability to use of the radiator additionally as a bench or a stand • ability to individually select the seat • simple cleaning (for example, with the special • Zehnder brush made of lamb’s wool) • dimensions to order • The radiator complies with the requirements of • the GUV (German Accident Insurance). • for installation on sub-floors or on finished floors
from 1012 to 2300 mm 410 mm from 136 to 210 mm 10 bar (Test pressure 13.0 bar) max. 120°
21
Technical parameters of the radiator
zehnder bank-radiator Model
Bench
Installation
Installation
Installation
height,
height,
length
depth
Heat capacity at system temperature 90/70/20째C
B4120/4 B5120/4 B6120/4 B4150/4 B5150/4 B6150/4 B4180/4 B5180/4 B6180/4 B4200/4 B5200/4 B6200/4 B4250/4 B5250/4 B6250/4 B4300/4 B5300/4 B6300/4 B4120/5 B5120/5 B6120/5 B4150/5 B5150/5 B6150/5 B4180/5 B5180/5 B6180/5 B4200/5 B5200/5 B6200/5 B4250/5 B5250/5 B6250/5 B4300/5 B5300/5 B6300/5 B4120/6 B5120/6 B6120/6 B4150/6 B5150/6 B6150/6 B4180/6 B5180/6 B6180/6
22
75/65/20째C
70/55/20째C
Exponent,
55/45/20째C
mm
mm
mm
mm
W
W
W
W
n
479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 571 571 571 571 571 571 571 571 571
184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 276 276 276 276 276 276 276 276 276
1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
957 1150 1364 1151 1411 1676 1384 1695 2013 1531 1893 2235 1942 2418 2881 2404 3001 3557 1161 1397 1640 1382 1696 1998 1663 2031 2403 1797 2225 2649 2328 2901 3422 2887 3607 4231 1389 1610 1912 1666 1969 2322 1948 2358 2792
766 921 1092 922 1130 1342 1108 1357 1612 1226 1516 1790 1555 1936 2307 1925 2403 2848 930 1119 1313 1107 1358 1600 1332 1626 1924 1439 1782 2121 1864 2323 2740 2312 2888 3388 1112 1289 1531 1334 1577 1859 1560 1888 2236
619 744 882 745 913 1084 895 1096 1302 990 1224 1446 1256 1563 1863 1555 1941 2300 751 904 1060 894 1097 1292 1076 1313 1554 1162 1439 1713 1505 1876 2213 1867 2332 2736 898 1041 1236 1077 1274 1501 1260 1525 1806
399 480 569 481 589 700 578 708 841 639 791 933 811 1010 1203 1004 1253 1485 485 583 685 577 708 834 695 848 1003 750 929 1106 972 1211 1429 1206 1506 1767 580 672 798 696 822 969 813 984 1166
1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26
Technical parameters per section
zehnder bank-radiator Model
B4120/4 B5120/4 B6120/4 B4150/4 B5150/4 B6150/4 B4180/4 B5180/4 B6180/4 B4200/4 B5200/4 B6200/4 B4250/4 B5250/4 B6250/4 B4300/4 B5300/4 B6300/4 B4120/5 B5120/5 B6120/5 B4150/5 B5150/5 B6150/5 B4180/5 B5180/5 B6180/5 B4200/5 B5200/5 B6200/5 B4250/5 B5250/5 B6250/5 B4300/5 B5300/5 B6300/5 B4120/6 B5120/6 B6120/6 B4150/6 B5150/6 B6150/6 B4180/6 B5180/6 B6180/6
Bench
Installation
Installation
Installation
Surface
Water
Weight
Radiant
Normal water
height,
height,
length,
depth
area
content,
without water,
heat share,
flow rate,
mm
mm
mm
mm
m2
l
kg
%
kg/hr
479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 479 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 525 571 571 571 571 571 571 571 571 571
184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 184 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 276 276 276 276 276 276 276 276 276
1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
1,49 1,87 2,25 1,87 2,34 2,82 2,25 2,82 3,38 2,50 3,13 3,76 3,13 3,92 4,70 3,76 4,70 5,64 1,87 2,34 2,82 2,34 2,93 3,52 2,81 3,52 4,23 3,13 3,91 4,70 3,91 4,90 5,88 4,70 5,88 7,06 2,24 2,81 3,38 2,80 3,52 4,22 3,37 4,22 5,07
8,36 10,28 12,32 10,28 12,68 15,20 12,20 15,08 18,08 13,48 16,68 20,00 16,88 20,68 24,80 19,88 24,68 29,60 10,45 12,85 15,40 12,85 15,85 19,00 15,25 18,85 22,60 16,85 20,85 25,00 20,85 25,85 31,00 24,85 30,85 37,00 12,54 15,42 18,48 15,42 19,02 22,80 18,30 22,62 27,12
15,00 18,84 22,48 18,60 23,32 27,88 22,20 27,84 33,28 24,60 30,84 36,88 30,60 38,32 45,88 36,60 45,84 54,88 18,75 23,55 28,10 23,25 29,15 34,85 27,75 34,80 41,60 30,75 38,55 46,10 38,25 47,90 57,35 45,75 57,30 68,60 22,50 28,26 33,72 27,90 34,98 41,82 33,30 41,76 49,92
17 16 15 17 16 15 17 16 15 17 16 15 17 16 15 17 16 15 16 15 14 16 15 14 16 15 14 16 15 14 16 15 14 16 15 14 16 14 13 16 14 13 16 14 13
66,00 79,00 94,00 79,00 97,00 115,00 95,00 117,00 139,00 105,00 130,00 154,00 134,00 166,00 198,00 166,00 207,00 245,00 80,00 96,00 113,00 95,00 117,00 138,00 115,00 140,00 165,00 124,00 153,00 182,00 160,00 200,00 236,00 199,00 248,00 291,00 96,00 111,00 132,00 115,00 136,00 160,00 134,00 162,00 192,00
23
Technical parameters of the radiator
zehnder bank-radiator Model
Bench
Installation
Installation
Installation
height,
height,
length
depth
Heat capacity at system temperature 90/70/20째C
B4200/6 B5200/6 B6200/6 B4250/6 B5250/6 B6250/6 B4300/6 B5300/6 B6300/6 B4120/7 B5120/7 B6120/7 B4150/7 B5150/7 B6150/7 B4180/7 B5180/7 B6180/7 B4200/7 B5200/7 B6200/7 B4250/7 B5250/7 B6250/7 B4300/7 B5300/7 B6300/7 B4120/8 B5120/8 B6120/8 B4150/8 B5150/8 B6150/8 B4180/8 B5180/8 B6180/8 B4200/8 B5200/8 B6200/8 B4250/8 B5250/8 B6250/8 B4300/8 B5300/8 B6300/8
24
75/65/20째C
Exponent,
70/55/20째C
55/45/20째C
mm
mm
mm
mm
W
W
W
W
n
571 571 571 571 571 571 571 571 571 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663
276 276 276 276 276 276 276 276 276 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368
2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
2139 2628 3103 2729 3377 3982 3374 4186 4930 1472 1847 2167 1873 2279 2675 2235 2740 3206 2475 3052 3563 3146 3909 4592 3891 4847 5666 1726 2076 2424 2087 2560 2993 2511 3053 3512 2771 3417 3971 3523 4378 5145 4343 5455 6329
1713 2104 2485 2185 2704 3189 2702 3352 3948 1179 1479 1735 1500 1825 2142 1790 2194 2567 1982 2444 2853 2519 3130 3677 3116 3881 4537 1382 1662 1941 1671 2050 2397 2011 2445 2812 2219 2736 3180 2821 3506 4120 3478 4368 5068
1383 1699 2007 1765 2184 2575 2182 2707 3188 952 1194 1401 1211 1474 1730 1446 1772 2073 1601 1974 2304 2034 2528 2969 2516 3134 3664 1116 1342 1567 1349 1655 1936 1624 1974 2271 1792 2209 2568 2278 2831 3327 2809 3527 4093
893 1097 1296 1139 1410 1663 1409 1748 2059 615 771 905 782 952 1117 933 1144 1339 1033 1274 1488 1314 1632 1917 1625 2024 2366 721 867 1012 871 1069 1250 1049 1275 1466 1157 1427 1658 1471 1828 2148 1814 2278 2643
1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26 1,26
Technical parameters per section
zehnder bank-radiator Model
B4200/6 B5200/6 B6200/6 B4250/6 B5250/6 B6250/6 B4300/6 B5300/6 B6300/6 B4120/7 B5120/7 B6120/7 B4150/7 B5150/7 B6150/7 B4180/7 B5180/7 B6180/7 B4200/7 B5200/7 B6200/7 B4250/7 B5250/7 B6250/7 B4300/7 B5300/7 B6300/7 B4120/8 B5120/8 B6120/8 B4150/8 B5150/8 B6150/8 B4180/8 B5180/8 B6180/8 B4200/8 B5200/8 B6200/8 B4250/8 B5250/8 B6250/8 B4300/8 B5300/8 B6300/8
Bench
Installation
Installation
Installation
Surface
Water
Weight
Radiant
Normal water
height,
height,
length,
depth
area
content,
without water,
heat share,
flow rate,
mm
mm
mm
mm
m2
l
kg
%
kg/hr
571 571 571 571 571 571 571 571 571 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663 663
276 276 276 276 276 276 276 276 276 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 322 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368 368
2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000 1200 1200 1200 1500 1500 1500 1800 1800 1800 2000 2000 2000 2500 2500 2500 3000 3000 3000
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
3,75 4,69 5,64 4,69 5,87 7,05 5,63 7,05 8,47 2,61 3,28 3,94 3,27 4,10 4,93 3,93 4,93 5,92 4,38 5,47 6,58 5,47 6,85 8,23 6,57 8,23 9,88 2,98 3,74 4,50 3,74 4,69 5,63 4,50 5,63 6,76 5,00 6,26 7,52 6,26 7,83 9,40 7,51 9,40 11,29
20,22 25,02 30,00 25,02 31,02 37,20 29,82 37,02 44,40 14,63 17,99 21,56 17,99 22,19 26,60 21,35 26,39 31,64 23,59 29,19 35,00 29,19 36,19 43,40 34,79 43,19 51,80 16,72 20,56 24,64 20,56 25,36 30,40 24,40 30,16 36,16 26,96 33,36 40,00 33,36 41,36 49,60 39,76 49,36 59,20
36,90 46,26 55,32 45,90 57,48 68,82 54,90 68,76 82,32 26,25 32,97 39,34 32,55 40,81 48,79 38,85 48,72 58,24 43,05 53,97 64,54 53,55 67,06 80,29 64,05 80,22 96,04 30,00 37,68 44,96 37,20 46,64 55,76 44,40 55,68 66,56 49,20 61,68 73,76 61,20 76,64 91,76 73,20 91,68 109,76
16 14 13 16 14 13 16 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13 15 14 13
147,00 181,00 214,00 188,00 232,00 274,00 232,00 288,00 339,00 101,00 127,00 149,00 129,00 157,00 184,00 154,00 189,00 221,00 170,00 210,00 245,00 217,00 269,00 316,00 268,00 334,00 390,00 119,00 143,00 167,00 144,00 176,00 206,00 173,00 210,00 242,00 191,00 235,00 273,00 243,00 301,00 354,00 299,00 376,00 436,00
25
Technical data
zehnder bank-radiator 5-column model
6-column model
L1 BL
250
250
250
S
136
173
210
120
precast floor raw soil
40x10
60
4xØ9
240
240
240
90
H1 BH L1 BL S
= bench height including the feet (BH + 295 mm) = number of sections x 46 mm = total length, including the bench frame (BL + 200 mm) = radiator length, mm = (starting with BL = 2500 mm: 3 feet) = BL - 300 mm
Dimensions with horizontal connections
Dimensions with vertical connections
X
33
BL BH = radiator height BL = radiator length X = connection dimension in the horizontal direction = BL - 66 mm Y = connection dimension in the vertical direction = BH - 46 mm L = air vent * = for 1/2” and 3/8” connections (15 mm at 3/4”)
26
12*
BL
12*
BH
14
Y
L
33
H1
BH min.4x46 max.8x46
H1
BH min.4x46 max.8x46
H1
BH min.4x46 max.8x46
bank carrier
120
240
30
25
4-column model
Technical parameters of the radiator
zehnder charleston bank Installation height 430 mm from finished floor, radiator installation height 260 mm Model
Installation
Installation
Number
length,
depth,
of sections
Heat capacity at system temperature 90/70/20째C
CB 4026-22 CB 5026-22 CB 6026-22 CB 4026-27 CB 5026-27 CB 6026-27 CB 4026-31 CB 5026-31 CB 6026-31 CB 4026-35 CB 5026-35 CB 6026-35 CB 4026-38 CB 5026-38 CB 6026-38 CB 4026-44 CB 5026-44 CB 6026-44 CB 4026-50 CB 5026-50 CB 6026-50
Model
CB 4026-22 CB 5026-22 CB 6026-22 CB 4026-27 CB 5026-27 CB 6026-27 CB 4026-31 CB 5026-31 CB 6026-31 CB 4026-35 CB 5026-35 CB 6026-35 CB 4026-38 CB 5026-38 CB 6026-38 CB 4026-44 CB 5026-44 CB 6026-44 CB 4026-50 CB 5026-50 CB 6026-50
mm
mm
1012 1012 1012 1242 1242 1242 1426 1426 1426 1610 1610 1610 1748 1748 1748 2024 2024 2024 2300 2300 2300
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
22 22 22 27 27 27 31 31 31 35 35 35 38 38 38 44 44 44 50 50 50
75/65/20째C
70/55/20째C
Exponent, 55/45/20째C
W
W
W
W
n
1001 1237 1472 1229 1518 1807 1411 1743 2075 1593 1968 2343 1729 2136 2543 2002 2474 2945 2275 2811 3346
803 992 1177 986 1218 1445 1132 1398 1659 1278 1579 1873 1387 1714 2033 1606 1984 2354 1825 2255 2675
650 803 949 797 985 1165 915 1131 1337 1033 1277 1510 1122 1386 1639 1299 1605 1898 1476 1824 2157
421 520 611 517 638 749 593 733 860 670 827 971 727 898 1055 842 1040 1221 957 1182 1388
1,25 1,25 1,27 1,25 1,25 1,27 1,25 1,25 1,27 1,25 1,25 1,27 1,25 1,25 1,27 1,25 1,25 1,27 1,25 1,25 1,27
Bench
Installation
Installation
Installation
Number of
Surface
Water
Weight
Radiant
Normal water
height,
height,
length,
depth
sections
area
content,
without water,
heat share,
flow rate,
mm
mm
mm
mm
430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430
260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
1012 1012 1012 1242 1242 1242 1426 1426 1426 1610 1610 1610 1748 1748 1748 2024 2024 2024 2300 2300 2300
136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210 136 173 210
22 22 22 27 27 27 31 31 31 35 35 35 38 38 38 44 44 44 50 50 50
m2
l
kg
%
kg/hr
1,72 2,18 2,64 2,11 2,67 3,24 2,42 3,07 3,72 2,73 3,47 4,20 2,96 3,76 4,56 3,43 4,36 5,28 3,90 4,95 6,00
13,64 16,50 19,36 16,74 20,25 23,76 19,22 23,25 27,28 21,70 26,25 30,80 23,56 28,50 33,44 27,28 33,00 38,72 31,00 37,50 44,00
19,80 26,40 30,80 24,30 32,40 37,80 27,90 37,20 43,40 31,50 42,00 49,00 34,20 45,60 53,20 39,60 52,80 61,60 45,00 60,00 70,00
18 17 18 18 17 18 18 17 18 18 17 18 18 17 18 18 17 18 18 17 18
69,04 85,29 101,20 84,78 104,72 124,24 97,33 120,20 142,64 109,88 135,76 161,04 119,25 147,37 174,80 138,08 170,59 202,40 156,91 193,89 230,00
27
Connection codes / Special designs
zehnder charleston bank Standard connection codes (no additional cost) for zehnder charleston bank radiators If the connection method is not specified in the order, the radiator will be supplied with bottom down, 3 x 1/2” connection. The following standard connection options are possible: 1/2"L
L1/2"
243
423
1/2"
1/2"
1/2"
1/2"
V
R
R
V
Special connection modes for zehnder charleston bank radiator When placing the order, it is necessary to show the connection number (Nr.) and dimensions same-side
V
1
R
2
3 L
L 1
120
L 1
opposite-end
R
3
R
1
230 V
2
E
E
V
for monotube valve*, horizontal
3 L
for monotube valve*, vertical
3 L
V
L
L 1
V
3
R
R
2
L 1
3 L
1
420 4
2
V
2
3
R
4
R
2
3
4
no additional costÞ
V
3
40 4
2
L 1
3 L
V
320
140 4
4
L 1
4
V/R
3
43
23 2
3
240
R
20
1
1
V
443 2
R
2
L
4
L 1
4
1
V/R
R
3
2
223 2
V
410 4
1
vertically underneath
3 4
340 2
4
4
2
4
V/R
V/R
V = flow, R = return, L = air vent, E = water drain, B = blind plug, O = buffle (standard), • = buffle (100% watertight) *when placing the order, it is necessary to show information about the valve manufacturer
Angled models Ability to manufacture angled models: from 90° to 179°. When requesting pricing, it is necessary to provide drawings with the following dimensions: dimensions A, B, C and distance to wall WA in mm, angles · & ‚ in degrees. Templates submitted at order stage cannot be changed.
Curved models
R
B B
< AB
R
A
B
90
A
inside radius
outside radius
90
< AB
< AB
inside angle 90°
A
outside angle 90°
inside angle from 90° to 179°
Zehnder Charleston radiators can be produced in curved designs with radius not less than: for 4-column models: 750 mm for 5-column models: 900 mm for 6-column models: 1000 mm
B
< AB
< AB < AC
C
C
B
A
B
A
outside angle from 90° to 179°
28
< BC < AB double inside angle from 90° to 179°
A
double outside angle from 90° to 179°
When requesting pricing, it is necessary to provide drawings with the following dimensions: radius R, length, and distance to wall in mm. Templates submitted at order stage cannot be changed.
Technical data
zehnder charleston bank Horizontal connection
4-column model
=
6-column model
115
430
Fertigboden Finished floor 120
153
194
120 BH=260
=
115
5-column model
BL
14
71
14
89
141
Sub-floor Rohboden
108
178
215
Vertical connection
=
=
115
109
430
115
120
Finished floor Fertigboden
21
50*
50* BL
14
71
21
89
141
14
Sub-floor Rohboden
108 215
178
Brackets placement
115
115
=
BL =
115
115
=
=
=
115
Fertigboden Finished floor 120
120 BH=260
115
BL
430
BL
BH BL * * *
Sub-floor Rohboden
= height = length = with same-side connections, the flow is in the end section = and the return â&#x20AC;&#x201C; in the second section, from the right or = from the left. = with opposite-end connections, the flow is in the end section.
Regarding Completto design, see Zehnder Charleston.
29
zehnder Notes
30
zehnder Notes
31