Page of Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #: Air Handler Unit
System
N a Tr ti o ue n -T al es t
Equipment Location Area Served Equipment Manufacturer Model Serial Number
Air Data Total CFM (Fan) Total CFM (Outlet) Return Air CFM Outside Air CFM Static Pressure (Total/Ext.) Inlet Pressure Discharge Pressure Fan RPM
Specified
Actual
Specified
Actual
Motor Data Motor Manufacturer Motor HP / BHP Voltage / Phase / Cycles Amperage Motor RPM / SF Motor Sheave / Grooves
Specified
Actual
Specified
Actual
Fan Sheave / Belts Starter Heater Size Notes:
Page of Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #: Exhaust Fan Data
System
N a Tr tio ue na -T l es t
Equipment Location Area Served Equipment Manufactuer Model Serial Number Air Data Total CFM (Fan)
Specified
Actual
Specified
Actual
Specified
Actual
Specified
Actual
Total CFM (Outlet) Static Pressure Fan RPM
Motor Data Motor Manufacturer Motor HP / BHP Voltage / Phase / Cycles
Amperage
Motor RPM / SF
Motor Sheave / Grooves Fan Sheave / Belts
Starter Heater Size Notes:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Static Pressure Profile
N a Tr ti o ue n -T al es t
B
A
C
D
E
B
C
D
F
H
G
I
J
Unit
Notes:
A
E
F
G
H
I
J
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Pump Data Sheet
Pump Number
Pump Number Manufacturer
Manufacturer Size Impeller Service
N a Tr ti o ue n -T al es t
Size Impeller Service
Test Data
GPM
Design Actual Actual Discharge Actual Suction No Flow Discharge No Flow Suction No Flow Head 2.31 X
Manufacturer
Motor HP / RPM
Nameplate Volts Actual Volts Nameplate Amps
Actual Amps O/L's Protection Notes:
Ft. HD
=
BHP
Test Data Design Actual Actual Discharge Actual Suction No Flow Discharge No Flow Suction No Flow Head
Manufacturer Motor HP / RPM Nameplate Volts Actual Volts
Nameplate Amps Actual Amps O/L's Protection
GPM
2.31 X
Ft. HD
=
BHP
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #:
Flow Measuring Station
Mark
Size
Model
Design GPM PD
Test1 PD
Test2 PD
Final PD GPM
N a Tr ti o ue n -T al es t
Location
Notes:
Page of Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #: Cooling Tower
N a Tr ti o ue n -T al es t
Tower Number Equipment Manufacturer Model Serial Number Rated Capacity Motor Manufacturer Motor HP / BHP Voltage Amperage RPM / Service Factor Starter Heater Ambient Dry Bulb Wet Bulb On/ Off GPM Water On Water Off Fan RPM Belts Motor Sheave Fan Sheave Gear Manufacturer Model Notes:
Specified
Actual
Specified
Actual
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Chillers
Unit Number Manufacturer
N a Tr ti o ue n -T al es t
Capacity Model
Serial Number
Cooler
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
E.W.T. L.W.T
P.D. (FT) GPM
Condenser E.A.T
L.A.T P.D. (Ft) GPM
Electric (Volts) T1‐T2 T2‐T3 T3‐T1
Amps
T1 T2 T3
Notes:
Page of Date: Project: Manufacturer:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #:
Coil Performance Data Location
CFM Temperature MBH Design Actual EAT DB EAT WB LAT DB LAT WB Design Actual
N a Tr ti o ue n -T al es t
Unit
Notes:
Page of Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #: Heat Exchange Converter Test Report
N a Tr ti o ue n -T al es t
Unit Data Unit Data Service Rating ‐ MBH Manufacturer Model Number Serial Number
Steam Steam Press. PSI
Design
Actual
Design
Actual
Design
Actual
Primary Water Entering Water Temp. Leaving Water Temp. Pressure Drop (Ft.)
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
GPM
Secondary Water Entering Water Temp. Leaving Water Temp. Pressure Drop (Ft.) GPM Control Set Point Notes:
Page 1 of 1 Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #: Boiler Test Report
Unit Number
Equipment Location
Equipment Manufacturer
N a Tr tio ue na -T l es t
Model Number Serial Number
Type Fuel
Design
Operating Pressure
GPM / PD
Entering Water Temp. Leaving Water Temp. Safety Value Setting
High Limit Setting Operating Contr. Setting Output (KW)
Notes:
Actual
Design
Actual
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Electric Duct Heater
Coil Number
N a Tr ti o ue n -T al es t
Location Manufacturer Model Number KW / Stages / PH Volts
Amps
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
Design
Actual
T1‐T2 T2‐T3 T3‐T1 T1
T2 T3
Coil Number
Location
Manufacturer Model Number KW / Stages / PH
Volts
Amps
Notes:
T1‐T2 T2‐T3 T3‐T1 T1 T2 T3
Page of Date: Project:
Reheat Data Sheet Location
CFM Design Actual
Temperature EAT LAT
MBH Design Actual
N a Tr ti o ue n -T al es t
NTT PROJECT #:
Unit
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Notes:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Heating Coil Data
System
N a Tr ti o ue n -T al es t
Equipment Location Area Served Equipment Manufacturer CFM GPM / Coil P.D. (Ft)
Design
Actual
Design
Actual
Design
Actual
Design
Actual
E. / L.Water Temp. (F) Entering Air Temp. DB (F) Leaving Air Temp. DB (F) System Equipment Location
Area Served Equipment Manufacturer CFM GPM / Coil P.D. (Ft) E. / L.Water Temp. (F)
Entering Air Temp. DB (F) Leaving Air Temp. DB (F) Notes:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
Page of Date: Project:
NTT PROJECT #: Cooling Coil Data
System
N a Tr ti o ue n -T al es t
Equipment Location Area Served Equipment Manufacturer CFM GPM / Coil P.D. (Ft)
Design
Actual
Design
Actual
Design
Actual
Design
Actual
E. / L.Water Temp. (F) E. Air Temp. DB / WB (F) L. Air Temp. DB / WB (F) System Equipment Location
Area Served Equipment Manufacturer CFM GPM / Coil P.D. (Ft) E. / L.Water Temp. (F)
E. Air Temp. DB / WB (F) L. Air Temp. DB / WB (F) Notes:
Page of Date: Project:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #:
Control List
System
Type
Setpoint
Computer
Actual
Operation
N a Tr ti o ue a n -T l es t
Notes:
Page of Date: Project: System:
7639 Highway 79 Pinson, AL 35126 Phone: (205) 6819050 Fax: (205) 6814070
NTT PROJECT #:
Air Distribution Sheet Outlet
Room Number
Terminal Type Size
Factor
Design FPM CFM
Test ‐ FPM or CFM st
nd
rd
Actual FPM CFM
N a Tr ti o ue n -T al es t
Notes:
1
2
3