E R R O R M E M O R Y R E P O R T ------------------------------------Date: 01/01/15 14:27:08 ECU: D_EGS JobStatus: --- API-Job FsLesen: job status error - API-Job FsLesen: job status error ============================================================= Variant: DSC57 3 Error in error memory Error registration 1 : 0x005A: temporary system deactivation Error accurances: 243 Vehicle speed

<<<<!!! 2.75

km/h

ASC not passiv ABS-control passiv stop light switch off ASC-control passiv ACB passive HBA passive ECD passive HDC passive -----------------------------------------------------------------------------------Error registration 2 : 0x0021: wheel speed sensor front left Open circuit <<<<!!! Error accurances: 1 Vehicle speed 2.75 km/h ASC passiv ABS-control passiv stop light switch off ASC-control passiv ACB passive HBA passive ECD passive HDC passive -----------------------------------------------------------------------------------Error registration 3 : 0x0068: Error steering angle Control unit <<<<!!! Error accurances: 1 Vehicle speed 2.75 km/h ASC passiv ABS-control passiv stop light switch off ASC-control passiv ACB passive HBA passive ECD passive HDC passive -----------------------------------------------------------------------------------==================================================================================== Variant: DDE40KW0 1 Error in error memory Error registration 1 : 0x3505: glow device <<<<!!! Error accurances: 255 Logistic counter : 40 Error accure 1st time at: Engine speed Coolant temperature Einspritzmenge RPC rail pressure Fehler aufgetreten bei

0.00 1/min -4.84 Grad C 51.72 mm^3 0.00 bar 259530.00 km

Error accure 2nd time at: Engine speed Coolant temperature Einspritzmenge RPC rail pressure Fehler aufgetreten bei

824.18 1/min 39.53 Grad C 16.90 mm^3 307.23 bar 309320.00 km

Error accure last time at:: Engine speed

824.18

1/min


Coolant temperature Einspritzmenge RPC rail pressure Fehler aufgetreten bei

39.53 Grad C 16.90 mm^3 307.23 bar 309320.00 km

--Error present Sporadic error -----------Glow system - Glow-plug or Glow-plug relay Error code: 35 05 28 FF DC 80 00 35 65 00 65 61 80 21 76 21 35 05 28 FF DC 80 00 35 65 00 65 61 80 21 76 21 33 33 78 33 78 D4 33 78 D4 80 33 78 D4 80 21 33 78 D4 80 21 76 33 78 D4 80 21 76 21 33 78 D4 80 21 76 21 33 33 78 D4 80 21 76 21 33 78 33 78 D4 80 21 76 21 33 78 33 78 D4 80 21 76 21 33 78 ==================================================================================== Variant: LWS5_1B 4 Error in error memory Error registration 1 : 0x0004: 90 degrees difference of wiper too large (Adjustment operation) Error accurances: 0 Sporadic error Error code: 04 00 17 -----------------------------------------------------------------------------------Error registration 2 : 0x0001: Clamp 30 defective <<<<!!! Error accurances: 0 Sporadic error Error code: 01 00 03 -----------------------------------------------------------------------------------Error registration 3 : 0x0010: Watchdog <<<<!!! Error accurances: 0 Sporadic error Error code: 10 00 AF -----------------------------------------------------------------------------------Error registration 4 : 0x0009: not an ASC2-message <<<<!!! Error accurances: 0 Sporadic error Error code: 09 00 63 -----------------------------------------------------------------------------------==================================================================================== Ecu : D_00AC IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Ecu : D_0070 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: LCM_III >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Ecu : D_0066 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: LWR2A 1 Error in error memory Error registration 1 : 0x0001: signal error <<<<!!! Error accurances: 29 Outside temperature 0.00 degrees C


-------Error not present Error code: 01 1D 00 ==================================================================================== Variant: RLS_DS2 >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Ecu : D_0008 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: EWS3 3 Error in error memory Error registration 1 : 0x000F: Power-On-Reset <<<<!!! Error accurances: 31 statischer Fehler Error code: 0F 3F -----------------------------------------------------------------------------------Error registration 2 : 0x0013: WC-Toleranz erhoeht bei Schluessel Nummer 1 <<<<!!! Error accurances: 2 sporadischer Fehler Error code: 13 02 -----------------------------------------------------------------------------------Error registration 3 : 0x0010: Schluessel Nr.1 ungueltig wegen fehlerhafter Identifikation Error accurances: 1 sporadischer Fehler Error code: 10 01 -----------------------------------------------------------------------------------==================================================================================== Ecu : D_00C0 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: ZKE3_GM4 12 Error in error memory Error registration 1 : 0x00A6: mirror BT, potentiometer vertical or cable <<<<!!! Error accurances: 5 Static error -----------------------------------------------------------------------------------Error registration 2 : 0x00A4: mirror FT, potentiometer vertical or cable <<<<!!! Error accurances: 1 Static error -----------------------------------------------------------------------------------Error registration 3 : 0x00A7: mirror BT, potentiometer horizontal or cable <<<<!!! Error accurances: 3 Static error -----------------------------------------------------------------------------------Error registration 4 : 0x00A5: mirror FT, potentiometer horizontal or cable <<<<!!! Error accurances: 1 Static error -----------------------------------------------------------------------------------Error registration 5 : 0x0004: cable clamp R on the GM III <<<<!!! Error accurances: 1 Sporadic error -----------------------------------------------------------------------------------Error registration 6 : 0x00B0: open circuit mirror motor FT fold in <<<<!!! Error accurances: 1 Static error ------------------------------------------------------------------------------------


Error registration 7 : Error accurances: 1

0x00B2: open circuit mirror motor BT fold in

<<<<!!!

Static error -----------------------------------------------------------------------------------Error registration 8 : 0x007E: sunroof switch or connections defective <<<<!!! Error accurances: 20 Sporadic error -----------------------------------------------------------------------------------Error registration 9 : 0x005C: central locking mechanism BT short-circuited <<<<!!! Error accurances: 2 Sporadic error -----------------------------------------------------------------------------------Error registration 10 : 0x005B: central locking mechanism FT short-circuited Error accurances: 2

<<<<!!!

Sporadic error -----------------------------------------------------------------------------------Error registration 11 : 0x00A0: open circuit mirror heating FT or cable <<<<!!! Error accurances: 2 Sporadic error -----------------------------------------------------------------------------------Error registration 12 : 0x00A2: open circuit mirror heating BT or cable <<<<!!! Error accurances: 31 Static error -----------------------------------------------------------------------------------==================================================================================== Variant: SZM38 2 Error in error memory Error registration 1 : 0x0007: Heating surface Seat heating left Open circuit Error accurances: 12

<<<<!!!

Error not present Error code: 07 0C -----------------------------------------------------------------------------------Error registration 2 : 0x0008: Heating surface Seat heating right Open circuit Error accurances: 3

<<<<!!!

Error not present Error code: 08 03 -----------------------------------------------------------------------------------==================================================================================== Variant: MRS4 4 Error in error memory Error registration 1 : 0x0005: Zuendkreis ZK4 / Seitenairbag vorne links <<<<!!! Error accurances: 1 Error accure 1st time at: Beginnfehleruhr Endefehleruhr

12956357.00 12956362.00

Sek. Sek.

-Fehler nicht vorhanden ---Widerstand zu klein -Fehler nicht sporadisch Error code: 05 20 01 C5 B2 C5 C5 B2 CA -----------------------------------------------------------------------------------Error registration 2 : 0x0005: Zuendkreis ZK4 / Seitenairbag vorne links <<<<!!! Error accurances: 4 Error accure 1st time at: Beginnfehleruhr Endefehleruhr

11681719.00 13469545.00

Sek. Sek.


-Fehler nicht vorhanden ----Widerstand zu gross Fehler sporadisch Error code: 05 C0 04 B2 3F B7 CD 87 69 -----------------------------------------------------------------------------------Error registration 3 : 0x0051: Fehlerlampe (AWL) <<<<!!! Error accurances: 1 Error accure 1st time at: Beginnfehleruhr Endefehleruhr

10693684.00 10694463.00

Sek. Sek.

-Fehler nicht vorhanden -Masse-Schluss / Unterbrechung ---Fehler nicht sporadisch Error code: 51 08 01 A3 2C 34 A3 2F 3F -----------------------------------------------------------------------------------Error registration 4 : 0x0050: Versorgungsspannung <<<<!!! Error accurances: 8 Error accure 1st time at: Beginnfehleruhr Endefehleruhr

10693671.00 13385927.00

Sek. Sek.

-Fehler nicht vorhanden ---Unterspannung -Fehler sporadisch Error code: 50 A0 08 A3 2C 27 CC 40 C7 -----------------------------------------------------------------------------------==================================================================================== Variant: IKI 5 Error in error memory Error registration 1 : 0x0092: Gong_1 <<<<!!! Error accurances: 0 -Kurzschluss gegen Masse ---sporadischer Fehler -Error code: 92 82 00 -----------------------------------------------------------------------------------Error registration 2 : 0x00BD: EBV <<<<!!! Error accurances: 255 ----Fehler momentan vorhanden sporadischer Fehler Fehler durch externes Steuergeraet Error code: BD D0 FF -----------------------------------------------------------------------------------Error registration 3 : 0x0091: Gong_2 <<<<!!! Error accurances: 0


-Kurzschluss gegen Masse ---sporadischer Fehler -Error code: 91 82 00 -----------------------------------------------------------------------------------Error registration 4 : 0x008B: Gong_3 <<<<!!! Error accurances: 0 -Kurzschluss gegen Masse ---sporadischer Fehler -Error code: 8B 82 00 -----------------------------------------------------------------------------------Error registration 5 : 0x0044: Oeldruck <<<<!!! Error accurances: 0 ---ungueltiger Arbeitsbereich -sporadischer Fehler -Error code: 44 88 00 -----------------------------------------------------------------------------------==================================================================================== Ecu : D_00B0 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: IHKA39_5 1 Error in error memory Error registration 1 : 0x0032: Additional heater <<<<!!! Error accurances: 255 --Open circuit ---Error code: 32 04 FF 39 4E 4D BD 11 10 03 81 ==================================================================================== Variant: ZUHEIZ 3 Error in error memory Error registration 1 : 0x0002: Combusation air fan <<<<!!! Error accurances: 255 Water pump ON 48.00 0-n Cooling temperature 12.00 degrees Celsius --Open circuit ---Error code: 02 04 FF 30 0C -----------------------------------------------------------------------------------Error registration 2 : 0x0002: Combusation air fan <<<<!!! Error accurances: 178 Glowing 10 70.00 0-n Cooling temperature 250.00 degrees Celsius -Short circuit to ground ----


-Error code:

02 02 B2 46 FA

-----------------------------------------------------------------------------------Error registration 3 : 0x0003: Circulation pump <<<<!!! Error accurances: 255 Water pump ON 48.00 0-n Cooling temperature 7.00 degrees Celsius --Open circuit ---Error code: 03 04 FF 30 07 -----------------------------------------------------------------------------------==================================================================================== Variant: RADIO 1 Error in error memory Error registration 1 : 0x0002: Fehler an der Antennenstromversorgung <<<<!!! Error accurances: 3 Fehler momentan nicht vorhanden Error code: 00 83 ==================================================================================== Variant: DSP2 >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Ecu : D_0048 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: BIT2 >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Variant: BM_WIDE 2 Error in error memory Error registration 1 : 0x0003: radio status telegramm timeout <<<<!!! Error accurances: 31 -----------------------------------------------------------------------------------Error registration 2 : 0x0001: watchdog reset <<<<!!! Error accurances: 17 -----------------------------------------------------------------------------------==================================================================================== Variant: VIDEOMOD >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Ecu : D_003B ==================================================================================== Ecu : D_0048 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Variant: NAVMK3 >>>>>>>>>> No error found <<<<<<<<<<< ==================================================================================== Ecu : D_00BB SYS-0012: IDENTIFICATION ERROR ==================================================================================== Ecu : D_SITZ_B IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Ecu : D_SITZ_F IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== Ecu : D_0072 IFH-0009: NO RESPONSE FROM CONTROLUNIT ==================================================================================== ################################################################ This content will stored temporary temporะดr in ..\inpa\sgdat\na_fs.tmp ################################################################