Construction Documents

Page 1

GENERAL PROJECT NOTES

PROJECT DATA

1. THE CONTRACT DOCUMENS ARE THE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT.

PROJECT DESCRIPTON:

2. "INSTALL" MEANS SUPPLIED BY OTHERS, TO BE INSTALLED BY CONTRACTOR.

THIS PROJECT IS A PARTIAL RENOVATION TO THE SECOND FLOOR AT THE NORTH SIDE OF BURRUSS HALL. THERE IS NO CHANGE OF USE, INCREASE IN AREA, OR ACTIVITY FUNCTIONS.

3. "PROVIDE" MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE.

APPLICABLE CODES AND REFERENCE STANDARDS:

4. "TYPICAL" MEANS IDENTICAL FOR CONDITIONS NOTED.

INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) NATIONAL ELECTRIC CODE (NEC) AMERICANS WITH DISABILITIES ACT (ADA)

5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. VERIFY DIMENSIONS WITH FIELD CONDITIONS, IF DISCREPANCIES ARE DISCOVERED BETWEEN FIELD CONDITIONS AND DRAWINGS OR BETWEEN INDIVIDUAL DRAWINGS, CONTACT THE DESIGNER FOR RESOLUTION BEFORE PROCEEDING. 6. HORIZONTAL DIMENSIONS ARE TO/FROM FINISH FACE OF CONSTRUCTION, EXCEPT WHEN NOTED AS CENTERLINE (CL), DIMENSIONS ARE TO CENTERLINE OF FRAMING

bdaziodesigns.com

Consultant Address Address Address Phone

USE GROUP CLASSIFICATION (EXISTING SPACE): E (EDUCATION) A (ASSEMBLY) USE GROUP CLASSIFICATION (PROPOSED SPACE):

7. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB, EXCEPT WHERE NOTED TO BE FROM ABOVE FINISH FLOOR, (A.F.F.). 8. CUT AND FIT COMPONENTS FOR ALTERATION OF EXISTING WORK AND INSTALLATION OF NEW WORK. PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES. 9. PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING PERFORMANCE OF THE WORK. FIREPROOF NEW PENETRATIONS REQUIRED BY TEH WORK AND EXISTING PENETRATIONS IN EXPOSED PLENUM AREAS. 10. CONTRACTOR & SUB-CONTRACTORS SHALL COORDINATE THE LAYOUT AND EXACT LOCATIONS OF ALL PARTITIONS, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SWITCHES WITH DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. 11. CONTRACTOR SHALL PROVIDE MANUFACTURER'S SPECIFICATIONS, INSTALLATION INSTRUCTIONS, SHOP DRAWINGS AND SAMPLES FOR REVIEW AND APPROVAL OF ALL MATERIALS AND METHODS TO BE USED PRIOR TO ORDERING OR PROCEEDING WITH THE WORK.

A (ASSEMBLY) *NOTE: THERE IS NO CHANGE OF USE.

Consultant Address Address Address Phone

CONSTRUCTION TYPE: 2A NON-COMBUSTIBLE, PROTECTED OCCUPANT LOADS: EDUCATION AREAS CALCULATED AT ASSEMBLY AREAS CALCULATED AT

20 SQ.FT. PER OCCUPANT 15 SQ.FT. PER OCCUPANT

OCCUPANT LOAD: PROPOSED SPACE, SECOND FLOOR:

CODE: 482

ACTUAL: 130

PROJECT SQUARE FOOTAGE: PROPOSED SPACE, SECOND FLOOR

Consultant Address Address Address Phone

9,550 NET SQ.FT.

12. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED SPECIFICATIONS AND INSTALLATION PROCEDURES. IF THESE ARE CONTRARY TO THE CONTRACT DOCUMENTS, CONTRACT SHALL NOTIFY TEH DESIGNER, IN WRITING IMMEDIATELY, TO RESOLVE DISCREPANCIES PRIOR TO PROCEEDING. 13. CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE, CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY TO ALLOW DESIGNER A REASONABLE AMOUNT OF TIME TO SELECT A REASONABLE SUBSTITUTE. 14. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS OR DISCOLORATION. JOINTING SHALL BE TIGHT FITTING, NEAT AND WELL SCRIBED. TEH FINISH WORK SHALL NOT HAVE EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. 15. CONTRACTOR SHALL COMPLY WITH ALL BASE BUILDING REQUIREMENTS AND DESIGN CRITERIA. ALL WORK SHALL COMPLY WITH TEH APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL COMPLY. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO THE CURRENT APPLICABLE EDITIONS OR PUBLICATIONS OF THE FOLLOWING (OR OTHERWISE NOTED): A. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) B. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) C. NATIONAL ELECTRIC CODE (NEC) D. INTERNATIONAL PLUMBING CODE (IPC 2009 EDITION) E. INTERNATINOAL MECHANICAL CODE (IMC 2009 EDITION) F. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) G. AMERICANS WITH DISABILITIES ACT (ADA) H. LOCAL MUNICIPAL ORDINANCES AND AMENDMENTS TO THE CODES

Date

Description

SHEET INDEX SHEET NUMBER A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115

SHEET NAME COVER SHEET FIRE + LIFE SAFETY PLAN EXISTING PLAN DEMOLITION PLAN PLAN ENLARGED PLAN INTERIOR SECTIONS WALL SECTIONS INTERIOR ELEVATIONS INTERIOR WALL DETAILS MILLWORK DETAILS FINISH PLAN FURNITURE PLAN POWER + DATA PLAN RCP ENLARGED RCP PROJECT NAME

BURRUSS OPEN OFFICE VIRGINIA TECH DRAWING TITLE

COVER SHEET 02 MAY 2017

DATE PROJECT NO:

AREA OF NEW CONSTRUCTION BURRUSS HALL, ROOM 224A

SITE PLAN BURRUSS HALL, ROOM 224A

PROJECT NORTH

VICINITY MAP VIRGINIA TECH, BLACKSBURG, VIRGINIA

TRUE NORTH PROJECT NORTH

2017_0001

DRAWN BY:

B. DAZIO

CHECKED BY:

B. DAZIO

A100