THE P50 RANGE
BRITANNIA FIRE
THE P50 Breaking the Mould
Britannia Fire has chosen to provide three types of P50 extinguisher. Foam with a fire rating of 27A / 183B, ABC powder with a fire rating of 34A / 183B and Super BC powder with a fire rating of 233B. The high ratings achieved gives better fire cover than many larger extinguishers.
P50 Composite Extinguisher THE NEXT GENERATION
10 year guarantee No costly servicing No corrosion No split linings
6LTR FOAM
No danger of personal injury due to corrosion
The P50F 6ltr Foam fire extinguisher has fire fighting capabilities that make it effective on Class A materials, wood, paper and textiles and class B fires fuelled by paints, solvents and oils. The unit has also passed the EN3 safety requirements for accidental use on live electrical equipment. With the addition of antifreeze the foam has an improved operational temperature range from +60˚c to -10˚c.
100% recyclable due to no corrosion of parts
10 Y
EAR
GUARA
NTEE
Kevlar super strength Carbon neutral
10 Y
Lightweight for ease of operation
6KG ABC POWDER
EAR
EN3 and MED approved
The P50P 6kg ABC Powder fire extinguisher is designed to be installed in areas where there are a variety of fire hazards. ABC powder fire extinguishers can tackle fires on Class A materials, wood, paper and textiles, Class B fires, those fuelled by oils, paints and solvents etc, and class C fires which are fuelled by flammable gases such as propane and methane.
GUARA
NTEE
Manufacturer disposal of contents UV protection (100%) 20 year life
4KG SUPER BC POWDER The P50S 4kg Super BC powder fire extinguisher is based on potassium bicarbonate/urea complex, this unique extinguishing mechanism makes it up to five times more effective on high risk petrochemical installations. 1723 1st extinguisher 1910 carbon patented & tetrachloride 1866 soda-acid patented by Pyrene extinguisher patented Manufacturing by Francois Carlier of Delaware
10 YEAR GUARANTEE P50 extinguishers are manufactured to the highest standards and are supplied with a 10 year manufacturer’s parts guarantee and a 20 year life cycle and is 100% recyclable.
Britannia’s invention 1970 - the ‘seize and squeeze’ control valve
Britannia’s 1986 headcap incorporating the patented balance valve
Britannia’s 2011 patented composite extinguisher
Ashwellthorpe Industrial Estate Ashwellthorpe Norwich Norfolk NR16 1ER United Kingdom
SIZE CONTENTS STANDARD MARINE TYPES FIRE CAPACITY CODE CODE OF FIRE RATING
FILLED HEIGHT EN3 WEIGHT APPROVED
FOAM
6ltr
AFFF
P50F
P50FM
AB
27A / 183B
8.5
570
Yes
POWDER
6kg
ABC
P50P
P50PM
ABC
34A / 183B
8.5
570
Yes
POWDER
4kg
Super BC
P50S
P50SM
B
233B
6.5
570
Yes
Tel: +44 (0)1508 488416 Fax: +44 (0)1508 481753 Email: sales@britannia-fire.co.uk
BRITANNIA FIRE
THE P50 COMPOSITE EXTINGUISHER
LEADING THE WORLD IN FIRE TECHNOLOGY
The P50 low-maintenance extinguisher is the latest development in the UK fire extinguisher industry. These extinguishers are certified to EN3 and MED with a 20 year life, requiring no discharge testing or re-fills for 10 years.
We have used design technology pioneered by motor racing, defence, aircraft and aerospace industries. It uses an extremely tough, yet light fibre material from the aramid family known by the name Kevlar. Kevlar is so tough it is used as the primary composite material in Gas Bottles, bulletproof vests and fire proof gloves!
The P50 is designed to remove corrosion and reduce maintenance because it only requires a simple visual inspection and checking of the gauges. Unlike standard fire extinguishers the P50 requires: No discharge testing at 5 years
MAINTENANCE INSPECTION RACING CAR BODYWORK
AIRPLANE MANUFACTURE
The P50 is approved under EN3 with additional testing to the composite butane and propane gas cylinder regulations witnessed by Apragaz. Under these gas cylinder regulations a 12,000-cycle test is required. The test is 0 to 25 Bar, 12,000 times, after which the unit must complete the crush test and the burst tests as EN3 requires. All extinguishers must pass a minimum 55 bar test. However P50 extinguishers have a burst pressure consistently reaching in excess of 85 bar.
KEVLAR HAS BEEN USED IN MANY APPLICATIONS
No corrosion checks
The extinguisher maintenance programme is a simple two step process which staff members can carry out on a monthly basis.
APPROVALS & TESTING MUCH HIGHER THAN EN3!
Fire testing is carried out in Britannia’s purpose built facility, witnessed by Apragaz and British Standards.
SPACE SHUTTLE
Visually check for damage Check the gauges are showing operational pressure in green segment
Cylinder after the crush and burst test.
Yearly inspection by trained personnel or a Britannia appointed distributor (giving third party qualification). Visually check for damage
P50 Standard - Magnetic pressure test
Check the gauges are showing operational pressure using a magnet to zero - on removal the gauge will show it is operational. If the pressure is in the red segment refill under the 10 year maintenance instructions
FIRE GLOVES
BREATHING APPARATUS
A HIGH DENSITY POLYETHYLENE CASING PROTECTS THE KEVLAR WOUND INNER BODY P50 extinguishers incorporate two patented elements the loose weave and the locking neck ring. This innovative design uses magnetic gauges for checking and certifying the operational pressure. Added features of being corrosion free, lightweight and extremely durable.
Check the base for damage and check the manufactured indicator is within the 10 year life span Record inspection detail on the back of the extinguisher (using a permanent marker) and in the company log book
MANUFACTURED TO THE HIGHEST STANDARDS
The ten year maintenance refilling to be carried out by a Britannia appointed distributor or trained engineer.
BULLETPROOF VESTS
GAS BOTTLES
HOW IS IT DESIGNED?
EN 3 FIRE TEST APPROVAL GUIDE Class A Wood - Pinus silvestris 0
8A
13A
21A
27A
34A
43A
2 gauges to calibrate against the other 34
Aramid (Kevlar) strong inner core
The number of sticks calculates the distance in metres, 43A = 4.3 metres long
Class B Liquid - Heptane
Use headcap spanner to open (right) Replacement of the foam/powder P50 Marine Schrader Valve for refilling 34 55 70B 89B 113B 144B
LS FOR F VA I O
T
MARINE APPROVED
UV protective outer casing
EQUIPMEN
A TISH PPR RI B
RE
Overhaul the headcap, fit new ‘O’ rings and valve spindle Re-pressurise with nitrogen to operational pressure through hose fitting or Schrader Valve Fit new pull-tight seal
CE RT IFIE D TO
B S E N3
EN3
The new P50 range has been designed to shipping requirements, allowing it to be refilled onboard. 0029
Certification EN3 Approval No: EN3 - 7:11/259
3 metres The tray size represents the number of litres, 233B = 233 litres
183B