24x36 new house weg

Page 1

BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION INTERIOR SQUARE FOOTAGE: ( ACRES- SQUARE FEET)

LAYOUT PAGE TABLE SHEET # DESCRIPTION 1 TITLE SHEET 2 FOOT PRINT MAIN LEVEL 3 MAIN LEVEL FLOOR PLAN 4 UPPER LEVEL FLOOR PLAN 5 LOWER BASEMENT LEVEL 6 ROOF PLAN 7 ELEVATION 1 FRONT 8 ELEVATION 2 LEFT SIDE 9 ELEVATION 3 REAR 10 ELEVATION 4 RIGHT SIDE 11 DOOR/WINDOW PLAN BASEMENT LOWER LEVEL 12 DOOR WINDOW PLAN MAIN 13 DOOR/WINDOW PLAN UPPER LEVEL 14 BASEMENT LEVEL-RED LINES MAIN 15 MAIN LEVEL-RED LINES BASEMENT 16 UPPER LEVEL-RED LINES MAIN 17 PERPSECTIVE 18 PERPSECTIVE 19 PERSPECTIVE

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

PRELIMINARIES NOT FOR CONSTRUCTION

LOT

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

TITLE SHEET SCALE: 1/4" = 1' - 0"

SHEET: 1 OF 19


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

4,892 SQUARE FOOTAGE BASEMENT LEVEL. FROM EXTERIOR FINISH MATERIAL. INCLUDES PORCHES AND GARAGE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

FOOT PRINT MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 2 OF 19


21'

10"X10" COLUMNS WITH STEEL POST INSIDE. (TYP.)

BY: JENNY BURGER 85'-0 1/2"

1'-9 1/2"

13'-8 1/2"

19'-7"

3'-7"

3'-4"

3'-4"

36'-7"

5'-9 3/4"

21'

SHUTTER HERE ONLY

25'-8"

6'-0 1/2"

3'-0 1/4"

3'

3'-0 1/2"

3'

3'-10"

4'-6"

3'-4"

3'-4"

3'-4"

36'-7"

9'-10"

12'-7"

3'-4"

3'-4"

4'-6"

25'-8"

DECK

10"

4'-5"

4'-6"

183 SQ FT

5'-0 1/2"

14'-1 1/2"

14'-1 1/2"

PORCH 331 SQ FT

1'-9 1/2"

COMPUTER DRAWING TECHNICIAN

ROUND METAL BALUSTERS TREX DECKING

21' 15'-2 1/2"

1'-6 1/2"

STAIRS DOWN

5'-1"

3' -1 "

15'-6"

2'-3"

HEATED FLOOR

22'-0 1/2" 292 SQ FT

WATER CLOSET

10'-3 1/2"

5'-4"

6'-4 1/2"

5'

SAUNA

24'-8"

DINING

4'-5"

15'-8"

BUILT-IN CABINETRY

20'-4 1/2"

GLASS WALL ON 4" CURB

32 SQ FT

3'-10"

10'-9 1/2"

3'-11"

BENCH

6'-9 3/4"

3'-10"

48" KNEE WALL

9 1/2"

3'-4" 407 SQ FT

3'

36'-9"

5'-2"

3'-2 3/4"

DESK

KITCHEN 79 SQ FT

INSTALL SOFFIT ABOVE PANTRIES

7'-3 1/4"

5'-1" 4'-7"

NO DOOR CASING IN SHAFT ELEVATOR 23 SQ FT MECHANICAL DOOR

13'-0 1/2"

1'-9 1/2" 2'-7 1/4"

15'

BASE TRIM: 9.5" CR RECEPTACLES AND REGISTERS IN BASE BOARD CROWN: COVE 5.25" FOUNDATION WALLS: 10" CONCRETE MAIN LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR UPPER LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR FLOOR JOIST: 16" WEB MAIN LEVEL 16" TGI ON UPPER LEVEL RAFTERS: 2X6 DOORS: 80" TALL TRIM: 1X4 WITH BACK BAND FLOORING: MAIN AND LAUNDRY HARDWOOD, BEDROOMSCARPET, BATHROOMS-TILE.

16'

5 SQ FT

SEE MANUFACTURER'S ADD SINK IN GARAGE-CONFIRM LOCATION SPECS DO NOT DROP THE GARAGE FLOOR BEFORE CONSTRUCTING SHAFTCONFIRM SHAFT DIMENSIONS

3'-5 1/4"

UPPER LEVEL: WINDOW MOUNT 80" - DOOR HEIGHT 80" BASEMENT LEVEL: WINDOW MOUNT 96" - DOOR HEIGHT 80"-

STAIRS: RISE 7.75"X11" TREAD INCLUDING OVERHANG

1'-2"

3'-11"

2'

UP

MECHANICAL

1'-7 1/4"

13'-6"

ENTRY CLNG HGHT: 120" 167 SQ FT

E7

22'-0 1/2"

LIBRARY CLNG HGHT: 120"

11"

ARCHED NICHE' OPENING 11" DEEP X 48" TALL X27" WIDE 32" TO BOTTOM OF NICHE OPENING TO FLOOR.

8'-6 1/4"

7'-8"

PANTRIES

12'-1 3/4"

212 SQ FT

3'-11"

STAIRS 32 SQ FT

2'-3"

SHOE CABINET

MAIN LEVEL: WINDOW MOUNT 96" INTERIOR DOOR HEIGHT: 80" DOOR HEIGHT IN FOYER 96" - EXTERIOR DOOR HEIGHT: 96"

12'-8 1/2"

1'-6"

1'-9"

8'-10 1/2"

BUILT IN CABINETS

Elevation 7

132 SQ FT

11'-11 1/2" 2'-6"

6" JACK

4'

16'-10 1/2"

LAUNDRY

3'-6 1/2"

4'-6"

2'-6"

COUNTER ABOVE WASHER DRYER

16'-7 3/4" 10'-4"

8'-4"

NO CASING

5'-9 1/2"

INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL: EXTERIOR DIMENSIONS ARE FROM STUD TO STUD. ROUND ALL DRYWALL CORNERS CEILING HEIGHTS: 12' BASEMENT- (CONFIRM IF CLNG TO BE DROPPED TO 120") 9' MAIN 10' GREAT ROOM, LIBRARY, FOYER, SUN ROOM 9' UPPER

2'-7 1/2" IRONING BOARD

6'-4 1/2"

24'-8"

1'-2"

DOUBLE OVENS

18'-11 1/2"

GREAT ROOM CLNG HGHT: 120"

3'-4"

SEE CABINET LAYOUT FOR ALL CABINETRY

5'

GARAGE INSTALL "CURB" AGAINST HOUSE WALLS

10'-11 1/4"

PLEASE VERIFY STOVE FIRE LACE MODEL NUMBER AND CUT OUT DIMENSIONS BEFORE CONSTRUCTING SHAFT AND CHIMNEY.

20'

4'-9 1/4"

ISLAND

18'-5 3/4"

1'-11 1/2"

11'-6"

40'-0 1/2"

WOOD STOVE APPROX. 26" X 36"

36" INDUCTION COOK TOP

19'-1"

8'-6"

7'-9"

325 SQ FT

219 SQ FT

2'

3'-6"

KITCHEN

CLOSET

16'

3'-6"

WASTE RECYCLE

CONFIRM REF. LOCATION

52'-3"

1'-9"

9 1/2"

5'

6'-6 3/4"

NO HEATED FLOOR

3'

11'

PRELIMINARIES NOT FOR CONSTRUCTION

1'-10"

11'-5 1/2"

MAIL LEVEL

PORCH

8'-1"

5'-11 1/2"

BASEMENT FLOOR: TILE AND POLISHED CONCRETE ROUND DOWNSPOUTS AND HALF ROUND GUTTERS. DOWNSPOUTS ARE TO BE PIPED UNDER GROUND AWAY FROM THE HOUSE. 11'-5 1/2"

6 SQ FT

3'-4 1/2"

CLOSET

1'-9"

INSTALL "CURB" AGAINST HOUSE WALLS

CURVED DRIVE WAY WITH A DECORATIVE APRON AND 18" BAND

2'-4 1/2" 1/2" 2'-4

10'-5 1/2"

8'-1"

1076 SQ FT

25'-6"

GARAGE

1'-10"

10'-10"

257 SQ FT

29'-5" 6'-11 1/2"

25' 3'-3"

2'

2'-11"

8' 17'

7'-5 1/2"

3'-4"

UP

CONFIRM IF THIS COLUMN IN NECESSARY

1'-6"

23'-7"

27'-6"

5'-1"

3'

33 SQ FT

6'-7"

FOYER DOORS 96" TALL POWDER ROOM

7'-2 1/2"

4'-3"

18'

3'-9" 8'

2'-7 3/4"

4'-11"

2'-9 3/4"

2'-6 1/4"

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

COVED CEILING

208 SQ FT

HEATED FLOOR

63'-7 1/2"

3'-4"

210 SQ FT

MASTER BATH

CONFIRM TYPE

VANITY KNEE SPACE

358 SQ FT

VAULT

MASTER BDRM

SOFFIT

E2

SUN ROOM

BUILT-IN CABINETRY

14'

2'-3"

E4

3'-4"

NO SHOWER DOOR BENCH

VAULT

3'-9"

14'

10'-7"

DROP FLOOR SYSTEM

2'-6" 14'-6"

34 SQ FT

14'-4 1/2"

6'

SHOWER

4'-6"

GLASS WALL ON 4" CURB

ADJUSTABLE POLE

HALL 17 SQ FT

NO CASING

14' TALL CABINET HAMPER IN BASE

7'-7 1/2"

6'

5'-6"

2'-3"

2'

2'-7 3/4" LINEN CABINET

6'-1 3/4"

3'-5 1/2"

19'-0 1/2"

3' 10'-2 1/2"

3'-9" 1 1/2"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36")

85'-0 1/2"

DATE ISSUED:

7/27/2016 E1 LIVING AREA 3047 SQ FT

MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1' - 0"

SHEET: 3 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

77'-3 1/2"

4'-4"

39' 59'-4 1/2"

21'-1 1/2"

14'-7" 1'-5"

3'-3 1/2"

MOUNT THE TOP OF THESE WINDOWS AT 90" AFF

2'

5'-1 1/2"

1'-5 1/2"

4 1/2"

1'-5 1/2"

7'-4"

1'-5 1/2"

3'-6"

7'-4 1/2"

MOUNT THE TOP OF THESE WINDOWS AT 90" AFF

MOUNT THE TOP OF THESE WINDOWS AT 90" AFF

CLOSET 19 SQ FT

OFFICE 228 SQ FT

2'-4"

19'-4"

CLOSET 26 SQ FT

6'-1"

FUTURE PROJECT ROOM FINISH THIS ROOM 12'-5"

CLNG HGHT: 96"

3'-8 1/2"

THIS FLOOR STEPS UP 12" FROM THE 120" TALL CEILING BELOW

37 SQ FT

FINISHED STORAGE WITH DRYWALL

8'

TUB SHOWER

1'-10 1/2"

8'-3 1/4"

11'-4"

21'-2 1/2"

6'-6 1/2"

21'-2" 5'-6 1/2"

HALL 261 SQ FT

THIS FLOOR STEPS UP 12" FROM THE 120" TALL CEILING BELOW 4'-4 3/4"

7'-11 3/4"

5'

59 SQ FT

CLNG HGHT: 96"

OPEN BELOW

36 SQ FT

9 SQ FT

7'-11"

1'-11"

2'

ELEVATOR 23 SQ FT

4'-2"

192 SQ FT

CLNG HGHT: 96"

10'-10"

CLOSET 12 SQ FT

7'-10"

E7

13'

5'-1"

BEDROOM 2 THIS FLOOR STEPS UP 12" FROM THE 120" TALL CEILING BELOW

6'-0 1/2"

1'-2"

6 SQ FT

NO DOOR CASING IN SHAFT

4'-7"

5'-2 1/4"

27'-6"

12'-3 1/2"

18'-8"

FUTURE BEDROOM WITH DRYWALL

BASE TRIM: 9.5" CR RECEPTACLES AND REGISTERS IN BASE BOARD CROWN: COVE 5.25" FOUNDATION WALLS: 10" CONCRETE MAIN LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR UPPER LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR FLOOR JOIST: 16" WEB MAIN LEVEL 16" TGI ON UPPER LEVEL RAFTERS: 2X6 DOORS: 80" TALL TRIM: 1X4 WITH BACK BAND FLOORING: MAIN AND LAUNDRY HARDWOOD, BEDROOMSCARPET, BATHROOMS-TILE. BASEMENT FLOOR: TILE AND POLISHED CONCRETE ROUND DOWNSPOUTS AND HALF ROUND GUTTERS. DOWNSPOUTS ARE TO BE PIPED UNDER GROUND AWAY FROM THE HOUSE.

CENTER WINDOWS WITH DOOR BELOW

224 SQ FT

UPPER LEVEL: WINDOW MOUNT 80" - DOOR HEIGHT 80" BASEMENT LEVEL: WINDOW MOUNT 96" - DOOR HEIGHT 80"

19'-2 1/4"

10'-10 1/2"

6'-7"

THIS FLOOR STEPS UP 12" FROM THE 120" TALL CEILING BELOW

FUTURE BEDROOMS UNFINISHED

W08

SHAFT

Elevation 7

5'-8 1/2"

8'-1 1/4"

MAIN LEVEL: WINDOW MOUNT 96" INTERIOR DOOR HEIGHT: 80" DOOR HEIGHT IN FOYER 96" - EXTERIOR DOOR HEIGHT: 96"

5'-11 3/4"

UNFINISHED ATTIC SEE MANUFACTURER'S SPECS BEFORE CONSTRUCTING SHAFTCONFIRM SHAFT DIMENSIONS

10'-2"

9'-11"

DN

13'-3 1/2"

4'-4 3/4"

1/2"

E9

3'-6"

OPEN BELOW

3'-6"

11'

13'-3"

Elevation 9

CLNG HGHT: 96"

INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL: EXTERIOR DIMENSIONS ARE FROM STUD TO STUD. ROUND ALL DRYWALL CORNERS CEILING HEIGHTS: 12' BASEMENT- (CONFIRM IF CLNG TO BE DROPPED TO 120") 9' MAIN 10' GREAT ROOM, LIBRARY, FOYER, SUN ROOM 9' UPPER

10'-9 3/4"

BATH

HALL 46 SQ FT

STEP

11'

331 SQ FT

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

7'-3 1/2"

3'-4"

7'-4 1/2"

1'-6"

1'-6"

7'

23'-7"

63'-7 1/2"

95 SQ FT

8'-5"

STORAGE UNFINISHED

ACCESS DOOR

FRAME FOR 36" DOOR

6'-6 1/2"

32'-7 3/4"

2'-3"

1'-9"

9'-10"

4'-8"

163 SQ FT

5'-11"

3'

BATH

6'-11"

20'-11 1/2"

1'-8"

HALL 66 SQ FT

3'-10 1/2"

10'-5"

ACCESS DOOR

14'-1" 11'-6 3/4"

4'-6"

11'-6 3/4"

8'

NO CASING

125 SQ FT

1'-9"

1'-10" 9 1/2"

BATH 54 SQ FT

1'-6 1/2"

ATTIC UNFINISHED

11'-7"

10'-9"

3' WOOD STOVE VENT

3'-10"

2'

6'-6 1/2"

UNFINISHED ATTIC -INSTALL SUBFLOOR IN PORTION OF ATTIC 11'-11 1/2"

40'-0 1/2"

40'-0 1/2"

FRAME FOR 36" DOOR AND COVER WITH DRYWALL

22'-0 1/2"

PRELIMINARIES NOT FOR CONSTRUCTION

15'-7"

4'-3"

18'

3'-9"

8'

19'-0 1/2"

19'-0 1/2"

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

3'-9 1/2"

12'-0 3/4"

188 SQ FT

12'-0 1/2"

BEDROOM 1

6'-11"

THIS FLOOR STEPS UP 12" FROM THE 120" TALL CEILING BELOW

8'-1"

7'-5"

E2

7'-9"

E4

2'

E1

LIVING AREA 2614 SQ FT

SHEET SIZE ARCH D (24" x 36")

45'-0 1/2"

DATE ISSUED:

7/27/2016

UPPER LEVEL FLOOR PLAN SCALE: 1/4" = 1' - 0"

SHEET: 4 OF 19


BY: JENNY BURGER

85'-0 1/2"

4'

2'-4 1/2"

20'-5"

CONCRETE PAD TO GO UNDER STAIRS

36'-7"

16'-5 1/2"

3'-11 1/2"

3'

3'-4"

3'-4"

25'-8"

16'-2 1/2"

10'-8 1/2"

6'-7 1/2"

3'-4"

7'-4"

3'-4"

COMPUTER DRAWING TECHNICIAN

STAIRS ARE NOT TO GO PAST THIS POINT UP

REINFORCED CONCRETE SLAB COVERED WITH STONE PATIO

SEE ENGINEER'S DRAWINGS FOR EXACT FOUNDATION WALL FOOTING POST, AND FOOTING DIMENSIONS, CONSTRUCTION, AND PLACEMENT.

PORCH

15'-5"

338 SQ FT

REINFORCED CONCRETE SLAB COVERED WITH STONE PATIO

FUTURE GYM 349 SQ FT

POLISHED AND SEALED CONCRETE FLOOR

10'-4 1/4"

INSTALL DRYWALL

13'-11"

FUTURE HALL 115 SQ FT

FINISHED DRYWALL POLISHED AND SEALED CONCRETE FLOOR

FUTURE ENTERTAINMENT ROOM

FUTURE EXERCISE ROOM

306 SQ FT

215 SQ FT

TILE FLOOR

TILE FLOOR INSTALL DRYWALL

INSTALL DRYWALL

STUCCO WALL

POLISHED AND SEALED CONCRETE FLOOR

WOOD STOVE

7'-9"

FUTURE 1/2 BATH

FUTURE BATH

21 SQ FT

49 SQ FT

INSTALL DRYWALL

3'

TILE FLOOR

NO CASING

POLISHED AND SEALED CONCRETE FLOOR

NO CASING REF

DW

PANTRY

UP 6'-11"

3'-6"

STAIRS

POLISHED AND SEALED CONCRETE FLOOR MECHANICAL

NO DOOR CASING IN SHAFT. DROP SLAB 12" LIFT

5'-1 1/2"

23 SQ FT

INSTALL DRYWALL

FRAME FOR FUTURE 36" DOORDRYWALL HERE

MECHANICAL DOOR

14'-11 1/2"

E7

3'-4 1/2"

6'-3"

4" 3000 PSI CONC.SLAB REINFORCED WITH WWF 6X6 - W1.4 X W1.4 ON 4" CRUSHED STONE BASE

4'-7"

22'-0 1/2"

310 SQ FT

UNFINISHED NO DRYWALL

STUCCO WALL

SEE MANUFACTURER'S SPECS BEFORE CONSTRUCTING SHAFTCONFIRM SHAFT DIMENSIONS

22'-1"

UNFINISHED NO DRYWALL

SLOPE 1/16" PER FOOT, MIN.

STORM SHELTER 223 SQ FT

10'-1 1/2"

1030 SQ FT

INSTALL "CURB" AGAINST HOUSE WALLS

SEE ENGINEER'S DRAWINGS FOR EXACT FOOTING CONSTRUCTION, PLACEMENT, AND DIMENSIONS. PLEASE CONFIRM WITH ENGINEER AND SURVEYOR WHICH WALLS ARE TO BE 10" CONCRETE WITH OR WITHOUT BRICK.

10'-2 1/2"

GARAGE ABOVE

AIR VENT TO OUT SIDE WOULD YOU LIKE THE ABOVE BRICK TO ALIGN FLUSH ON TOP OF THE CONCRETE WALL OR FOR THE BRICK TO OVERHANG THE BRICK WALL??????

POLISHED AND SEALED CONCRETE FLOOR

6'-9"

CURVED DRIVE WAY WITH A DECORATIVE APRON AND 18" BAND

2'-2"

FUTURE WORK ROOM

35 SQ FT

1'

13'-1 1/2"

10'-11"

Elevation 7

2'-6 1/2"

" -3

POLISHED AND SEALED CONCRETE FLOORTWO FLOOR DRAINS

BASE TRIM: 9.5" CR RECEPTACLES AND REGISTERS IN BASE BOARD CROWN: COVE 5.25" FOUNDATION WALLS: 10" CONCRETE MAIN LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR UPPER LEVEL STUDS: 2X6 EXTERIOR, 2X4 INTERIOR FLOOR JOIST: 16" WEB MAIN LEVEL 16" TGI ON UPPER LEVEL RAFTERS: 2X6 DOORS: 80" TALL TRIM: 1X4 WITH BACK BAND FLOORING: MAIN AND LAUNDRY HARDWOOD, BEDROOMSCARPET, BATHROOMS-TILE. BASEMENT FLOOR: TILE AND POLISHED CONCRETE ROUND DOWNSPOUTS AND HALF ROUND GUTTERS. DOWNSPOUTS ARE TO BE PIPED UNDER GROUND AWAY FROM THE HOUSE.

3'-5 3/4"

14'

47'-8 1/2"

3'

3'-2 1/4"

UNFINISHED NO DRYWALL

CONFIRM THESE WINDOWS WITH ELEVATION AND THEIR HEIGHTS

19'-6 1/4"

CONFIRM WITH MECHANICAL ENGINEER HVAC, WATER HEATER, AND ELECTRICAL PANEL LOCATIONS. RADON VENT

INSTALL DRYWALL

FUTURE WORK ROOM

21'-0 1/2"

10'-4 1/2"

7'-10"

6'-6"

6'-9 1/2"

UNFINISHED-NO DRYWALL

POLISHED AND SEALED CONCRETE FLOOR

155 SQ FT

W17

74 SQ FT

17'-2 3/4"

109 SQ FT

FUTURE HALL

TILE FLOOR

HVAC UTILITY

WH

STORAGE

13'-1"

338 SQ FT

1'-10"

14'-3"

INSTALL "CURB" AGAINST HOUSE WALLS

6'-11"

GAS

4'-1"

18'-9 1/2"

NO CASING

SLOPE 1/16" PER FOOT, MIN.

25'-8"

19'-5 3/4"

5'-10 1/2"

79'-0 1/2"

106 SQ FT

POLISHED AND SEALED CONCRETE FLOOR

310 SQ FT

UPPER LEVEL: WINDOW MOUNT 80" - DOOR HEIGHT 80" BASEMENT LEVEL: WINDOW MOUNT 96" - DOOR HEIGHT 80"

15'-7"

STORAGE

FUTURE ENTERTAINMENT

5'-10 1/2"

INSTALL DRYWALL

INSTALL DRYWALL

21'-4 1/2"

19'-10"

1'-8"

40'-0 1/2"

POLISHED AND SEALED CONCRETE FLOOR

4" 3000 PSI CONC.SLAB REINFORCED WITH WWF 6X6 - W1.4 X W1.4 ON 4" CRUSHED STONE BASE

PLEASE VERIFY ABOVE STOVE FIREPLACE MODEL NUMBER AND CUT OUT DIMENSIONS BEFORE CONSTRUCTING SHAFT, FOOTINGS, AND CHIMNEY.

79'-0 1/2"

18'-9 1/2"

MAIN LEVEL: WINDOW MOUNT 96" INTERIOR DOOR HEIGHT: 80" DOOR HEIGHT IN FOYER 96" - EXTERIOR DOOR HEIGHT: 96"

9'-10"

9'-10"

TILE FLOOR

12'-7 3/4"

5'

4'-3"

11'-5"

INSTALL DRYWALL

6'-3 1/2"

4'-3 3/4"

BUILD RETAINING WALL. LOCATION AN LENGTH TO BE DETERMINED.

FIBER GLASS SHOWER

CONFIRM LVL HEADER

10"

3'-5"

THIS LINE IS THE EXTERIOR SIDE OF THE EXTERIOR STUD ABOVE.

INTERIOR DIMENSIONS ARE FROM DRYWALL TO DRYWALL: EXTERIOR DIMENSIONS ARE FROM STUD TO STUD. ROUND ALL DRYWALL CORNERS CEILING HEIGHTS: 12' BASEMENT- (CONFIRM IF CLNG TO BE DROPPED TO 120") 9' MAIN 10' GREAT ROOM, LIBRARY, FOYER, SUN ROOM 9' UPPER

37'-10 1/2"

STEEL DOOR

E4

13'-11"

13'-5 3/4"

14'-4 1/2"

UNFINISHED NO DRYWALL

8'-8 1/4"

E2

24'-4"

FLOOR DRAIN

171 SQ FT

CONCRETE PAD

21'-11 1/2"

6'

FUTURE GARDEN TOOLS

15'-5"

14'-5"

5'-3 1/2"

12'-8"

ELECTRIC WATER 7' HEATER

PARTIAL CONCRETE WALL ON BOTTOM OF WALL

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

TRANSOM

PRELIMINARIES NOT FOR CONSTRUCTION

W01

15'-6"

W04

CENTER DOOR ON WALL

WH

W05

STUCCO WALL

W04

1'

W04

W06

4'-0 3/4"

4'-6"

7' W02

W05

9'-2"

8'-10"

W06

12' TALL CONCRETE WALL

15'-5"

LINE FROM DECK ABOVE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

THIS LINE IS THE EXTERIOR SIDE OF THE EXTERIOR STUD ABOVE.

7/27/2016

25'-1 3/4" 25'-11 3/4"

29'-3 1/4"

LOWER BASEMENT LEVEL

85'-0 1/2"

SCALE: 1/4" = 1' - 0" E1

LIVING AREA 3319 SQ FT

SHEET: 5 OF 19


8 : 12

8 : 12

8 : 12

COMPUTER DRAWING TECHNICIAN

30 YEAR ARCHITECTURAL SHINGLES OVERHANG FROM STUD: 21" FASCIA: 7.25"

METAL STANDING SEAM ROOF

QUEEN ANNE RETURNS: METAL STANDING SEAM 6 : 12

4 3/4 : 12 4 3/4 : 12

3 13/16 : 12

3 : 12

METAL STANDING SEAM ROOF

PRELIMINARIES NOT FOR CONSTRUCTION

4 : 12

6 : 12

10 : 12

10 : 12

METAL STANDING SEAM ROOF

OFF SET CHIMNEY FROM FIREPLACE BELOW

10 : 12

CHIMNEY

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

10 : 12

10 : 12

10 : 12

4 15/16 : 12

10 : 12

2 3/16 : 12 10 : 12 10 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

2 7/8 : 12

8 : 12

10 : 12

METAL STANDING SEAM ROOFPORCH OVERHANG: 12"

SHEET SIZE ARCH D (24" x 36")

8 : 12

DATE ISSUED:

7/27/2016

10 : 12 8 : 12

8 : 12

BY: JENNY BURGER

ROOF PLAN SCALE: 1/4" = 1' - 0"

SHEET: 6 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

I WILL ADD THE QUEEN ANNE RETURNS AND DOWNSPOUTS ONCE THE ROOF IS FINALIZED.

ELEVATION 1 FRONT 6128VT

PRELIMINARIES NOT FOR CONSTRUCTION

4 15/16 : 12

INSTALL BIG GUTTER WITH DOWNSPOUT HERE

10 : 12

1/2"

10 : 12

8 : 12

8 : 12

8 : 12

W02

8" FRIEZE MOLDING + 3" CROWN

W06

W01

W09

W04

1/2"

FLASHING METAL STANDING SEAM ROOF

3 13/16 : 12

6" JACK-STONE JACK ON FRONT ONLY 6" JACK-STONE JACK ON FRONT ONLY

8" FRIEZE MOLDING + 3" CROWN

FINISHED CEILING HEIGHT

APPROX.

W10

10" W02

W09

W08

3/4"

W09

W03

9'

W11 D02

D09

D05

D01

D05

THESE STONE BASES ARE TO BE 36" TALL 1/2"

6" JACK-STONE JACK ON FRONT ONLY

6" JACKSTONE JACK ON FRONT ONLY

JOIST

CONFIRM BRICK BAND PATTERN NUMBER OF STAIRS TBD BY GRADE 6 : 12

10'

CONFIRM IF BASEMENT CEILING IS TO BE DROPPED TO 120"

12'

NUMBER OF STAIRS TBD BY GRADE.

10"X10" PT COLUMNS ON STONE BASE WITH STEEL POST INSIDE. (TYP.)

SEE ENGINEER'S DRAWINGS FOR POST AND FOOTING SIZE, CONSTRUCTION, AND PLACEMENT

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

JOIST

1'-4"

NG

2 7/8 : 12

8" JACK STONE

9'

FLASH I

6 : 12

1'-4"

3/4"

FLASHING

3'

9'

FINISHED CEILING HEIGHT

8" FRIEZE MOLDING + 3" CROWN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

ELEVATION 1 FRONT SCALE: 1/4" = 1' - 0"

SHEET: 7 OF 19


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

CONFIRM CHIMNEY HEIGHT

1/2"

10 : 12

FINISHED CEILING HEIGHT

FLASHING 10 : 12 W05

1/2"

6 : 12

8" STONE JACKS

W01

BAHAMAS SHUTTER HERE ONLY

W01

W01

D43

BAND PATTERN TBD

JOIST 3'

3/4"

1/2"

1'-4"

3'

9'

APPROX.

FINISHED CEILING HEIGHT

W12

10"X10" PT COLUMNS WITH STEEL POST INSIDE. (TYP.)

TREX: RAILS, NEWELS, BALUSTERS, STAIRS PAINT: STRINGERS, & COLUMNS

6 : 12

METAL ROOF 11'-6"

10"X10" PT COLUMNS ON STONE BASE WITH STEEL POST INSIDE. (TYP.)

FLASHING

BRICK WALL LENGTH TO BE DETERMINED BY GRADE D41

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

3'-6"

10'

CONFIRM IF BASEMENT CEILING IS TO BE DROPPED TO 120"

12'

3'

10 : 12

D43

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

8" FRIEZE MOLDING + 3" CROWN

JOIST

6" JACKS BRICK

9'

W05

6 : 12

1'-4"

3/4"

9'

8" FRIEZE MOLDING + 3" CROWN

NUMBER OF STEPS TO BE DETERMINED BY GRADE

SEE ENGINEER'S DRAWINGS FOR POST AND FOOTING SIZE, CONSTRUCTION, AND PLACEMENT

RISE: 7" RUN 11"

SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

ELEVATION 2 LEFT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 8 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

I WILL ADD THE QUEEN ANNE RETURNS AND DOWNSPOUTS ONCE THE ROOF IS FINALIZED.

PRELIMINARIES NOT FOR CONSTRUCTION

CONFIRM CHIMNEY HEIGHT

ELEVATION 3 REAR

3 : 12

1/2"

10 : 12

10 : 12

W10

W10

W03

1/2"

FLASHING

8 : 12

VAULTED CEILING

JOIST

8" FRIEZE MOLDING + 3" CROWN 6" JACKS

APPROX.

W16

W03

W16

W03

W04

W05

W05

W04

W05

W03

W03

3/4"

1/2"

1'-4"

10"X10" PT COLUMNS WITH STEEL POST INSIDE. (TYP.)

W03

9'

W03

D08

3'

9'

FINISHED CEILING HEIGHT

6" JACKS

W16

8 : 12

JOIST

TREX: RAILS, NEWELS, BALUSTERS, STAIR TREADS

3'

1'-4"

4 : 12

SEE ENGINEER'S DRAWINGS FOR BAND LVL SIZE

BAND PATTERN TBD

FLASHING

PAINT STAIR STRINGERS, & COLUMNS

METAL ROOF

10 : 12

6" JACKS 6" JACKS

6 : 12 W01

W04

D01

W04

W04

APPOX.

11'-6"

W06

10"X10" PT COLUMNS ON STONE BASE WITH STEEL POST INSIDE. (TYP.)

D05

THESE STONE BASES ARE TO BE 42" TALL

3'-6"

W05

APPOX.

W06

12'-4"

W05

W02

THESE STONE BASES ARE TO BE 42" TALL

3"

CONFIRM IF BASEMENT CEILING IS TO BE DROPPED TO 120"

7"

10'

12'

3/4"

FLASHING

W03

STONE 4" REINFORCED CONCRETE SLAB

SEE ENGINEER'S DRAWINGS FOR POST AND FOOTING SIZE, CONSTRUCTION, AND PLACEMENT ROUND METAL BALUSTERS TREX DECKING

EXACT NUMBER OF STEPS TBD BY GRADE. RISE 7"-RUN 11"

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

9'

FINISHED CEILING HEIGHT

8" FRIEZE MOLDING + 3" CROWN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

ELEVATION 3 REAR SCALE: 1/4" = 1' - 0"

SHEET: 9 OF 19


BY: JENNY BURGER

2'

COMPUTER DRAWING TECHNICIAN

CONFIRM CHIMNEY HEIGHT

PRELIMINARIES NOT FOR CONSTRUCTION

10 : 12

10 : 12

10 : 12

1/2"

10 : 12

FLASHING

9'

FINISHED CEILING HEIGHT

8" FRIEZE MOLDING + 3" CROWN

FL AS

HI

NG

W08

W04 6 : 12

W09

1/2"

1'-4"

2 3/16 : 12

JOIST 6" JACKS BRICK

6" JACKS BRICK

10" WIDE PT POST (TYP.) W16

W16

W16

W16

W16

W16

3/4"

6 1/2"

1'-4"

JOIST

3'

3'

9'

9'

W07

BAND PATTERN TBD

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

APPROX.

8'-6"

FINISHED CEILING HEIGHT

6" JACKS BRICK

W17

10'

12'

3/4"

4 3/4 : 12

CONFIRM IF BASEMENT CEILING IS TO BE DROPPED TO 120"

CONFIRM WINDOW LOCATION AND SIZE GRADE ELEVATION

SEE ENGINEER'S DRAWINGS FOR POST AND FOOTING SIZE, CONSTRUCTION, AND PLACEMENT

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

ELEVATION 4 RIGHT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 10 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

W06

W02

W04

W04

W04

W05

W06

W05

W01 D01

D05

PRELIMINARIES NOT FOR CONSTRUCTION

D08

D27

D41

D04

D08

D10

D06

D06

D07 W17

3768

D27

D08

D03

4068

D35

D08

NUMBER D01 D02 D03 D04 D05 D06 D07 D08 D10 D27 D35 D41

LABEL 12068 3068 3068 3068 2668 2468 2468 3068 2468 2868 3080 5068

NUMBER W01 W02 W04 W05 W06 W17

LABEL 12010FX 2810FX 3066SC 3050SC 3050SC 5013FX

DOOR SCHEDULE DESCRIPTION QTY EXT. QUAD SLIDER-GLASS 1 STORM SHELTER DOOR 1 MECHANICAL ROOM DOOR 1 STEEL DOOR 1 HINGED EXTEIRIOR DOOR TEMPERED GLASS 1 HINGED-DOOR P04 2 STEEL DOOR 1 HINGED-DOOR P04 4 POCKET-DOOR P04 1 HINGED-DOOR P04 2 ELEVATOR DOOR 1 EXTERIOR DOUBLE DOOR 1

D02

DESCRIPTION FIXED GLASS FIXED GLASS SNGL CASEMENT-HR SNGL CASEMENT-HL SNGL CASEMENT-HR FIXED GLASS TEMPERED GLASS

FLOOR 0 0 0 0 0 0 0 0 0 0 0 0

WINDOW SCHEDULE QTY FLOOR EGRESS 1 0 1 0 3 0 2 0 2 0 1 0

HEADER 2X12X149" (2) 2X6X41" (2) 2X6X41" (2) 2X6X41" (2) 2X6X35" (2) 2X6X33" (2) 2X6X33" (2) 2X6X41" (2) 2X6X61" (2) 2X6X37" (2) 2X6X41" (2) 2X8X65" (2)

COMMENTS TEMPERED GLASS

HEADER CODE COMMENTS 2X12X148" (2) TEMPERED GLASS 2X6X36" (2) 2X6X40" (2) 2X6X40" (2) 2X6X40" (2) 2X8X64" (2) BASEMENT WINDOWS CONFIRM

CONFIRM CASEMENT OPENING LEFT OR RIGHT

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

3068

3068

3068

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

DOOR/WINDOW PLAN BASEMENT LOWER LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 11 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

D12

W03

W16

W03

W16

W03

W16

D07

W03

W03

W03

D08

W05

W04

W05

W05

W04

D13

3668

D13

PRELIMINARIES NOT FOR CONSTRUCTION

W16

W16

W12

D29 W16

D03 D19

W01

W03

D29

W16

W16

4680

D20

W01

D29 D15

D16

D13

W07

D10

D02

D09 D14 D17

D43 D06

W08 D04

W09

NUMBER D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D12 D13 D14 D15 D16 D17 D19 D20 D29 D43

LABEL 3080 12080 12080 2080 2080 2480 3080 3080 3080 5080 3080 3068 3080 5080 2668 3068 2868 2868 3068 9080

DOOR SCHEDULE DESCRIPTION QTY FRONT DOOR TEMPERED GLASS 1 GARAGE-C22-ARCH1-SOLID 1 INTERIOR QUAD SLIDING TEMPERED GLASS 1 HINGED-DOOR P04 1 SIDE LIGHTS TEMPERED GLASS 2 HINGED-DOOR P04 1 HINGED-GLASS 1 EXTERIOR GLASS DOOR BACK 1 EXTERIOR DOOR GLASS 1 DOUBLE HINGED-DORADO I DOOR 1 SCREEN DOOR 1 HINGED-DOOR P04 3 ELEVATOR DOOR 1 DOUBLE TEMPERED GLASS 1 POCKET-DOOR P04 1 ELEVATOR DOOR 1 POCKET-DOOR P04 1 HINGED-DOOR P04 1 POCKET-DOOR P04 3 GARAGE-C22-ARCH1-SOLID 2

FLOOR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

WINDOW SCHEDULE NUMBER LABEL DESCRIPTION QTY W01 3050SC SNGL CASEMENT-HR 3 W02 3062SC SNGL CASEMENT-HR 1 W03 3066SC SNGL CASEMENT-HR 7 W04 2866SC SNGL CASEMENT-HL 2 W05 2866SC SNGL CASEMENT-HR 3 W07 6666MU MULLED UNIT-HR 1 W08 2862SC SNGL CASEMENT-HL 1 W09 2862SC SNGL CASEMENT-HR 2 W10 2020FX FIXED GLASS 1 W11 3062SC SNGL CASEMENT-HL 1 W12 4010FX FIXED GLASS TEMPERED-SHOWER 1 W16 3066SC SNGL CASEMENT-HL 9 CONFIRM CASEMENT OPENING LEFT OR RIGHT

W10

D05

D01

D05

D43

HEADER 2X6X41" (2) 2X12X152" (2) 2X12X149" (2) 2X6X29" (2) 2X6X29" (2) 2X6X33" (2) 2X6X41" (2) 2X6X41" (2) 2X6X41" (2) 2X8X65" (2) 2X6X41" (2) 2X6X41" (2) 2X6X41" (2) 2X8X65" (2) 2X6X65" (2) 2X6X41" (2) 2X6X69 3/4" (2) 2X6X37" (2) 2X6X77" (2) 2X12X116" (2)

COMMENTS

FLOOR EGRESS 1 1 1 1 1 1 1 1 1 1 1 1

HEADER COMMENTS 2X6X40" (2) 2X6X40" (2) 2X6X40" (2) 2X6X36" (2) 2X6X36" (2) 2X10X81 9/16" (2) 2X6X36" (2) 2X6X36" (2) 2X6X28" (2) 2X6X40" (2) 2X8X52" (2) 2X6X40" (2)

TEMPERED GLASS

TEMPERED GLASS TEMPERED GLASS

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

W16 W01

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36")

W09

W11

DATE ISSUED:

7/27/2016

W02

DOOR WINDOW PLAN MAIN SCALE: 1/4" = 1' - 0"

SHEET: 12 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

MOUNT THE TOP OF THESE WINDOWS AT 90" AFF W10

W03

W10

PRELIMINARIES NOT FOR CONSTRUCTION

5068

W03

D09

D03

D05

D04

3068

5068

D09

W09 2468

D05

D02

4068

D12

D09 W08

DN

NUMBER D01 D02 D03 D04 D05 D06 D08 D09 D12

LABEL 5068 2668 2868 2468 2868 2668 3068 2468 3068

DESCRIPTION 4 DR. BIFOLD-LOUVERED ATTIC ACCESS DOOR HINGED-DOOR P04 POCKET-DOOR P04 HINGED-DOOR P04 HINGED-DOOR P04 ELEVATOR DOOR HINGED-DOOR P04 HINGED-DOOR P04

DOOR SCHEDULE DIMENSIONS (4) 15"X80"X1 3/4" L/R 30"X80"X1 3/8" L IN 32"X80"X1 3/8" L IN 28"X80"X1 3/8" R 32"X80"X1 3/8" R IN 30"X80"X1 3/8" R IN 36"X80"X1 3/4" L IN 28"X80"X1 3/8" L IN 36"X80"X1 3/8" R IN

QTY 1 1 3 1 2 1 1 3 1

FLOOR 2 2 2 2 2 2 2 2 2

HEADER 2X8X65" (2) 2X6X35" (2) 2X6X37" (2) 2X6X61" (2) 2X6X37" (2) 2X6X35" (2) 2X6X41" (2) 2X6X33" (2) 2X6X41" (2)

CONFIRM CASEMENT OPENING LEFT OR RIGHT D03

D01 D08 W04 D06

D03

W05

W01

NUMBER W01 W02 W03 W04 W05 W06 W08 W09 W10

LABEL 3040SC 3046SC 2840SC 3040SC 3050SC 3046SC 3016FX 2846SC 3640SC

WINDOW SCHEDULE DESCRIPTION QTY FLOOR EGRESS SNGL CASEMENT-HL 1 2 SNGL CASEMENT-HL 1 2 SNGL CASEMENT-HR 2 2 SNGL CASEMENT-HR 2 2 SNGL CASEMENT-HL 2 2 SNGL CASEMENT-HR 1 2 FIXED GLASS 1 2 SNGL CASEMENT-HR 2 2 SNGL CASEMENT-HR 2 2

HEADER 2X6X40" (2) 2X6X40" (2) 2X6X36" (2) 2X6X40" (2) 2X6X40" (2) 2X6X40" (2) 2X6X40" (2) 2X6X36" (2) 2X6X46" (2)

COMMENTS

W04

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

W05

W09

W02

COMMENTS

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

3068

3068

W06

SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

DOOR/WINDOW PLAN UPPER LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 13 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN UP

E4

WH

S

S S

E2

PRELIMINARIES NOT FOR CONSTRUCTION

S

S

S S

S

S

S

S NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

S WH

EP

E7 THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

S

S

S

S SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

BASEMENT LEVEL-RED LINES MAIN SCALE: 1/4" = 1' - 0" E1

SHEET: 14 OF 19


BY: JENNY BURGER

E4

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

E2

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

UP

E7 THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

UP

SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

MAIN LEVEL-RED LINES BASEMENT SCALE: 1/4" = 1' - 0" E1

SHEET: 15 OF 19


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

MOUNT THE TOP OF THESE WINDOWS AT 90" AFF

PRELIMINARIES NOT FOR CONSTRUCTION

E4

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

E2

E9 DN

E7

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016 E1

UPPER LEVEL-RED LINES MAIN SCALE: 1/4" = 1' - 0"

SHEET: 16 OF 19


BY: JENNY BURGER

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

PERPSECTIVE SCALE: 1/4" = 1' - 0"

SHEET: 17 OF 19


BY: JENNY BURGER

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

PERPSECTIVE SCALE: 1/4" = 1' - 0"

SHEET: 18 OF 19


BY: JENNY BURGER

NEW CONSTRUCTIONRESIDENTIAL SINGLE FAMILY OCCUPANCY - WOOD FRAME CONSTRUCTION

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ARCH D (24" x 36") DATE ISSUED:

7/27/2016

PERSPECTIVE SCALE: 1/4" = 1' - 0"

SHEET: 19 OF 19


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.