Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
TITLE SHEET SCALE: 1/4 = 1' - 0"
SHEET: 1 OF 9
2'-4" 13'-6"
183 SQ FT
8"
EXISTING BASEMENT FLOOR PLAN 2X6 STUDS TRIM 3.5" CROWN 7.5" BASE: 5" MAIN FLOORING CARPET
EP
17'-2 1/2"
UNFINISHED STORAGE
19'-6 1/2"
11'
S
S
S
S
6 1/2"
UNFINISHED STORAGE 243 SQ FT EP
FINISHED CEILING HEIGHT: 104 7/16" BOTTOM OF TRAY: 95 7/16" WH
4'-7"
8'-5"
7'-3"
WINE STORAGE
UTILITY
3068
UP
48 SQ FT
2668 T
16'-9"
13'-8 1/4"
9'-11 1/4"
3068
23'-8 7/8"
4'-2"
8"
FAMILY ROOM
5'
THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
19'-10"
737 SQ FT
BASEMENT RENOVATION
3068 3052DH
6'-4 1/2"
33'-9 7/8"
2'-4"
TV CABINETRY
7'-11 3/8"
3052DH
40'-2 3/4"
2'-8"
3052DH
3052DH
2'-4 3/4"
5'-6"
3068
2668
6'-1"
6 1/2"
17'-6 3/4"
42 SQ FT
TILE
14'-1 1/4"
176 SQ FT
5'-10"
6'-3 1/2"
7'-7 1/4"
8'
HALL
3'-9"
3068
16 STEPS
12'-0 1/2" WH
8'-6 1/2"
STAIRS 45 SQ FT
Jenny Burger CAD Technician
5'-4"
3052DH
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
3052DH
19'-2"
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
EXISTING BASEMENT FLOOR PLAN SCALE: 1/4 = 1' - 0"
SHEET: 2 OF 9
2'-4"
8"
13'-6"
183 SQ FT
17'-2 1/2"
UNFINISHED STORAGE
19'-6 1/2"
11'
S
S
S
S
6 1/2"
PROPOSED BASEMENT FLOOR PLAN 2X6 STUDS TRIM 3.5" CROWN 7.5" BASE: 5" MAIN FLOORING CARPET
UNFINISHED STORAGE 243 SQ FT
FINISHED CEILING HEIGHT: 104 7/16" BOTTOM OF TRAY: 95 7/16" 16'-0 5/8" GLASS DOORS & SHELVES WITH LIGHT. INSTALL LOCK ON DOOR ABOVE COUNTERTOP.
ALL APPLIANCES ARE INTEGRATED.
2'-6"
4'-2"
WH
WH
2'-6"
RELOCATE WATER HEATER, HVAC, REGISTER, AND THERMOSTAT.
3068 5'-4" TV
98 SQ FT
E5 DOUBLE FREEZER DRAWERS
RECESS HEADER INTO CEILING
ICE
REFRIGERATOR
DOUBLE DW DRAWERS
3068 3'-5 3/8"
3'-5 1/4"
Jenny Burger CAD Technician
30" MICRO DRAWER
WASTE PULL OUT
6'-1"
3'-5 3/8"
40 1/2" TALL KNEE WALL 30" WINE REFRIGERATORS
13'-8 1/4"
E3
4'-2" 1'
40'-2 3/4"
8"
23'-8 7/8"
3052DH
6'-4 1/2"
3052DH
3068 11'-5" 40 1/2" TALL KNEE WALL
5'
2'-4" 19'-10"
FAMILY ROOM
70" TV CABINETRY
7'-11 3/8"
1'-3"
BASEMENT RENOVATION
2'
963 SQ FT
E4
THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
1'-6"
3052DH
3052DH
2'-4 3/4" 5'-6"
3068
E2 BAR
16'-2 3/4"
E1
17'-6 3/4"
2668
7'-7 1/4"
ARCHED OPENING.
3'-9"
3068
16 STEPS
8'
8'-6 1/2"
UP
3052DH
3052DH
19'-2"
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
FLOOR PLAN OPTION 2 RAISED BAR SCALE: 1/4 = 1' - 0"
SHEET: 3 OF 9
Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
PERSPECTIVE SCALE: 1/4 = 1' - 0"
SHEET: 4 OF 9
Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
PERSPECTIVE SCALE: 1/4 = 1' - 0"
SHEET: 5 OF 9
Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
PERSPECTIVE SCALE: 1/4 = 1' - 0"
SHEET: 6 OF 9
Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
PERSPECTIVE SCALE: 1/4 = 1' - 0"
SHEET: 7 OF 9
Jenny Burger CAD Technician
BASEMENT RENOVATION THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
PERSPECTIVE SCALE: 1/4 = 1' - 0"
SHEET: 8 OF 9
3'
3'
3'-4 1/2"
7'
8'-8 1/2" 7'-11 3/8"
Jenny Burger CAD Technician DW
DW
ICE
3'
4'-6"
7'-6"
7'-11 3/8"
8'-9 3/8"
TV
FREEZER
30" MICROWAVE DRAWER
REF
BASEMENT RENOVATION DW
3'
4'-6"
7'
7'-6"
7'-11 3/8"
8'-9 3/8"
FREEZER
7'-11 3/8"
5"
DW
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
70" TV
2'-6"
CABLE BOXES AND MEDIA EQUIPMENT
CABLE BOXES AND MEDIA EQUIPMENT
THESE DRAWINGS ARE VISUAL REPRESENTATIONS AND DO NOT REFLECT THE EXACT FIXTURES (PLUMBING & ELECTRICAL), FINISHES, APPLIANCES, AND MILLWORK TO BE USED IN YOUR PROJECT. PLEASE CONFIRM WITH YOUR CONTRACTOR AND/ OR DESIGNER THE EXACT FIXTURES, FINISHES, MATERIALS TO BE SPECIFIED.
CABLE BOXES AND MEDIA EQUIPMENT
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
1/25/2018
ELEVATIONS SCALE: 1/2" 1/4 == 1' 1' -- 0" 0"
SHEET: 10 OF 9