Basement Havi.

Page 1

3' -3

1/ 4"

3/21/2012 @ 5:00:51 PM

1'-6 1/2"

11'-7"

3' -3

1/ 4"

8"

1'-6 1/2"

25'-7" x 11'-8"

'-7 19 2" 1/

EXISTING CONCRETE FOUNDATION WALLS

68 40

Door opening with header

EXISTING EXTERIOR BRICK WALLS

Unspecified

Ab ov (1 jo e fl 6" is oo r O t .C .)

WALL LEGEND

'-7 19

Existing Water heater

2" 1/

EXISTING 5.5" STUD WALLS

WALL LEGEND

EXISTING 5.5" + DRYWALL FURRED WALLS

Unspecified 10'-9" x 14'-5"

EXISTING EXTERIOR BRICK WALLS

Exercise Rm Rubber Floor

EXISTING 5.5" + DRYWALL INTERIOR WALLS 1/2 DRYWALL APPLIED TO EXISTING STUDS

Water heater

27'-10" x 11'-8"

EXISTING 5.5" STUD WALLS

14'-1" x 12'-9"

8' - 10 13/16" from concrete floor to bottom of above floor joist.

NEW INTERIOR 5.5 STUD, 1/2" DRYWALL FURRED WALLS HVAC

EXISTING 5.5" + DRYWALL FURRED WALLS

NEW INTERIOR 5.5 STUD, 1/2" DRYWALL WALLS 1' -4

3/ 8"

Ab ov (1 jo e fl 6" is oo r O t .C .)

3/ 8"

NEW INTERIOR 3.5 STUD, 1/2" DRYWALL WALLS 11'

1' -4

HVAC

1/ 4"

Unspecified

1' -0

EXISTING CONCRETE FOUNDATION WALLS

EXISTING 5.5" + DRYWALL INTERIOR WALLS

Mirrored wall

11'-7"

3'-4 3/4" 6'-1 3/8"

Hall 8' CEILING

9'-11"

8'-7" x 3'-4"

Unfinished

8'-7" x 9'-1"

12'-0" x 7'-2"

2868

7'-1 3/4" 5'

Game Room Carpet

5068 8'-7"

23'-5" x 12'-9"

14'-3 3/4"

2068

8'-6" x 1'-11"

6"

6'-11"

Existing hall clng hght: 105" New stair stringers

2'-6"

3'-7"

16'-4"

23'-6" x 16'-5"

3'-2"

13'-1" x 5'-4"

HSS 4"x4"x1/4" with PL 10"x10"x3/4" Base Plate + (4) 3/4" 0 Anchors

Existing joist (16" O.C.)

6 3/4" 4'-10 5/8"

Existing joist (16" O.C.)

7/8" 6 63/4"

1'-7"

3051DH

4'-3" x 4'-11"

HALL

FAMILY

HALL

Clng Hght: 104" 3'-4" x 2'-6"

4' 5'-5 3/8"

UP

4'-3 3/8"

3068

7'-7" x 10'-3"

1'-11 3/8"

UP

13'-10"

2'-6 3/8"

4'x4'x1' FTG with (6) #4 Bars Each Way. 12" soffit

2'-1"

4068 6"

4' -1 0"

FB3 (3) 1 3/4"x 11 7/8" LVL

FB2 (4) 1 3/4" x 18" LVL or (3) 14" x 20" LVL or W12x30

Jenny Burger CAD Technician

10'-3 1/4"

Steel door

3051DH

3068

Stone wall

3'-2"

9'-3 1/8"

Rebuild stairs New head height: 6' - 7"

(2) 1 3/4" x 11 7/8" LVL

3'-4" x 3'-1"

3'-7" x 10'-4" 5068

16'-4 3/4"

4'-5 1/2"

4'-3"

5068

WINE RM

Trey + coffered ceiling

4'-7 5/8" Ventless Fireplace

3'-6" 4'

3'-6 5/8" 4'-7 5/8"

HALL

3051DH

FAMILY 18'-5" x 15'-5"

8'-3" x 3'-6"

3'-4"

2468

French Door 2768

4068

7'-7 1/8"

4'-0 1/4"

3051DH

UP

6'-5 3/8"

CLOSET 8'-3" x 3'-6"

6'-5 3/8"

2468

3'-6 3/4"

Unfinished Closet

3' -1 0"

18'-10 3/4"

3'-7 1/2" 18'-10 3/4"

2'-1 1/2"

Existing Stud

4'

3068

CLOSET

2'-5 3/8" 2668

3"

1'-6"

8" 12'-9"

4'-0" x 7'-2"

15"Dx18"T Bench 3'-3"

12'-9"

1'-3 1/2"

4'-10 1/2" 3068

Hall Barrel Vault

BATH 5'-3" x 7'-2"

7"

15'-4 5/8"

Cedar Closet Clng: 86.75" 9'-0 5/8"

14'-4" x 12'-9"

Existing Ceiling Height: 86.75"

4'-10 1/2" 3068

1'-10 5/8"

17.5" tall ceiling wedge

4'-4 5/8"

10'-2" x 7'-2"

Existing 17.5" tall ceiling wedge

6'-7 1/2"

8' - 10 13/16" from concrete floor to bottom of above floor joist.

4' -1 0"

6'-5 1/4" 5'-3 1/8"

7'-1 5/8"

4'-4"

Exercise Room

12'

2'-1 1/2"

15.75 Tall Soffit 8'-7"

14'-3 3/4"

10'-1 3/4"

BATH

Existing Bathroom Wall

3'-3"

23'-4 3/4"

11'-9"

Linen Cab.

1'-9 1/4"

2668

Electrical Panels

New Wall

g t in xis E tud S

9'-11"

3'-6 1/2"

8 1/2"

16'-8 1/8" 3068

5'-5"

Existing electrical Panels will need to be relocated

3'

11'

3068

2'

2351DH

Integrated

14'-5 3/8"

12'-9 7/8"

2351DH

12'-5 5/8"

DW

POOL Room

4'

2351DH

2351DH

12" soffit

Play Room 34'-1" x 12'-10"

ICE

BAR Tin Ceiling

15'-10" x 12'-10"

Dry wall groin ceiling Integrated

4 1/4"

Wine Cellar 4 1/4"

REF.

12'-10 1/4"

2'-7 1/2"

4 1/4"

34'-1" 2'-3 3/4"

2351DH

2'-3 3/4"

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

2351DH

Waiscont paneling in pool area to match columnswith a 6" deep drink ledge

34'-1"

LIVING AREA 2078 sq ft

Existing unfinished area: 8' - 10 13/16" from concrete floor to bottom of above floor joist.

Haviland Basement Existing Ceiling Height: 8'

C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

2077 sq ft

New hardwood floors: 5" wide plank in all areas except the game room and exercise room. Crown: Cove + bead + backband

DATE ISSUED: 3/21/2012

REVISION DATE:

1) 2) 3)

DATE PRINTED: 3/21/2012 @ 5:00:51 PM

SHEET:

1 of 7


3' -3

1/ 4"

3/21/2012 @ 5:00:52 PM

1'-6 1/2"

11'-7" 8"

Ab ov (1 jo e fl 6" is oo r O t .C .)

'-7 19 2" 1/

EXISTING CONCRETE FOUNDATION WALLS

68 40

Door opening with header

EXISTING EXTERIOR BRICK WALLS

25'-7" x 11'-8"

Existing Water heater

EXISTING 5.5" STUD WALLS EXISTING 5.5" + DRYWALL FURRED WALLS

QTY 5 3 2 1 1 15 39 1 1 2 2 2 2

Unspecified 10'-9" x 14'-5"

Exercise Rm Rubber Floor

EXISTING 5.5" + DRYWALL INTERIOR WALLS

14'-1" x 12'-9"

NEW INTERIOR 5.5 STUD, 1/2" DRYWALL FURRED WALLS HVAC

R

R

R

R R

1' -0

1/2 DRYWALL APPLIED TO EXISTING STUDS

CEILING MOUNT CEILING MOUNT CEILING MOUNT CEILING MOUNT CEILING MOUNT CEILING MOUNT CEILING MOUNT CEILING MOUNT WALL MOUNT WALL MOUNT WALL MOUNT WALL MOUNT

ELECTRICAL SCHEDULE DESCRIPTION PUCK 48" RECESSED [48W6D] 96" RECESSED [96W6D] EXHAUST POOL TABLE LIGHT RECESSED DOWN LIGHT 4 RECESSED DOWN LIGHT 6 RECESSED VAPOR LIGHT MEDITERRANEAN PENDANT - OIL RUBBED BRONZE BOWL SCONCE (TRIPLE) - LIGHTING GREY CABLE JACK DUPLEX ELECTRICAL PANEL

1/ 4"

8' - 10 13/16" from concrete floor to bottom of above floor joist.

ATTACHED TO

Ab ov (1 jo e fl 6" is oo r O t .C .)

WALL LEGEND

Mirrored wall

Unspecified

3/ 8"

NEW INTERIOR 5.5 STUD, 1/2" DRYWALL WALLS 1' -4

R

R

R

11'

NEW INTERIOR 3.5 STUD, 1/2" DRYWALL WALLS

Existing electrical Panels will need to be relocated

8 1/2"

3068

3'

3'-4 3/4"

16'-8 1/8"

8'-7" x 3'-4"

BATH

1'-6"

Existing Bathroom Wall

3' -1 0" 4' -1 0"

2'-1 1/2" 3051DH

FAMILY

2'

6"

18'-5" x 15'-5" 15'-4 5/8" 3051DH

HSS 4"x4"x1/4" with PL 10"x10"x3/4" Base Plate + (4) 3/4" 0 Anchors

1'-7"

Existing joist (16" O.C.)

R UP

R

FB3 (3) 1 3/4"x 11 7/8" LVL

14'-5 3/8"

R

4" spot cans over bar top??

R

POOL Room

4'

Existing joist (16" O.C.)

R4

R4

R4

R4

R4

Tin Ceiling

REF.

Wine Cellar 4 1/4"

Existing joist (16" O.C.)

R

15'-10" x 12'-10"

B33 4 1/4"

R

R

Dry wall groin ceiling W96017 W186014R W184215R W66016

R

Jenny Burger CAD Technician

2351DH

Integrated

12'-9 7/8"

B15R

BAR Tin Ceiling

R

2'-6 3/8"

DW

B2820

R

R4

2351DH

12'-5 5/8"

ICE B15

R

R

R4

R

B30

6"

2'

7/8" 6 63/4"

SB27

2'

6"

6"

R

4'x4'x1' FTG with (6) #4 Bars Each Way.

DW

R

4'-7"

UP

R4

Existing joist (16" O.C.)

R

R

FB2 (4) 1 3/4" x 18" LVL or (3) 14" x 20" LVL or W12x30

B40

2'

R

R

5068 (2) 1 3/4" x 11 7/8" LVL

6'-11"

Existing hall clng hght: 105" New stair stringers

C Trey Ceiling

3'-5 5/8"

3'-2"

Plasma TV

R

3'-5 5/8"

4' 3068

R

Trey + coffered ceiling

3'-2"

9'-3 1/8"

HALL

R R

R

R

4'-7"

4'-7 5/8" Ventless Fireplace

13'-1" x 5'-4"

R

R

3DB21 3"

R

2'

UP

SB36

4'

6"

3'-4" x 3'-1"

Steel door

R4

6"

6" French Door 2768

Rebuild stairs New head height: 6' - 7"

4'-10 1/2" 3068

2' 2468

4'-0 1/4"

UP

Stone wall

3DB21

6'-5 3/8"

CLOSET

WINE RM

8' Tall ceiling

18'-10 3/4"

8'-3" x 3'-6"

3'-7" x 10'-4"

R

R4

CLOSET

3'-6"

7"

3068

8'-6" x 1'-11"

3'-6 5/8"

R

Electircal panels will need to be relocated.

4'-4 5/8"

4'-0" x 7'-2"

5' 5068 8'-7"

23'-5" x 12'-9"

1'-10 5/8"

12'-9"

Game Room Carpet

R

Hall Barrel Vault

15"Dx18"T Bench 3'-3"

14'-3 3/4"

R

Barrel Valt

7'-1 3/4"

6'-7 1/2"

Existing Ceiling Height: 86.75"

New Wall

10'-1 3/4"

10'-2" x 7'-2"

Existing 17.5" tall ceiling wedge

8"

Existing Stud

11'-9"

3'-3"

23'-4 3/4"

1'-9 1/4"

U192496R UF22496

g t in xis E tud S

Linen Cab.

2668

R

6'-1 3/8"

Hall 8' CEILING

9'-11"

3'-6 1/2"

3068

Integrated

B27

3DB15

R

R

R

R Groin Vault-Dry wall

W66016 W184215L W186018L W96021 R4

R4

R4

R4

R4

Plasma TV 2351DH

2'-3 3/4"

2351DH

2351DH

2351DH

2351DH

2351DH

Waiscont paneling in pool area to match columnswith a 6" deep drink ledge

C

34'-1"

LIVING AREA 2078 sq ft

C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

Existing unfinished area: 8' - 10 13/16" from concrete floor to bottom of above floor joist. DATE ISSUED:

New hardwood floors: 5" wide plank in all areas except the game room and exercise room. Crown: Cove + bead + backband

3/21/2012

REVISION DATE:

1) 2) 3)

DATE PRINTED: 3/21/2012 @ 5:00:52 PM

SHEET:

2 of 7


C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

! " 8"

3'-6"

3'

6'-6"

8'-10"

8'

8'

8'-10 7/8"

6" deep Drink ledge

DATE ISSUED: 3/21/2012

1) 2) 3)

REVISION DATE:

DATE PRINTED: 3/21/2012 @ 5:00:52 PM

SHEET:

3 of 7

Jenny Burger CAD Technician

10"

6"

8"

4"

3'

6'-6"

8'

8'-10"

8'-10 7/8"

1'-2"

4" 8" 3'

3'-6"

8'-10 3/4"

8'-10"

8'

1'-2"

1'

3/21/2012 @ 5:00:52 PM


C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

Jenny Burger CAD Technician

6'-6"

8'

8'-10 3/4"

8'-9"

& 6"

10"

1'-1"

1'

8"

" 8'

8'-9"

#$%

DATE ISSUED: 3/21/2012

1) 2) 3)

REVISION DATE:

DATE PRINTED: 3/21/2012 @ 5:00:53 PM

SHEET:

4 of 7

9"

10"

3/21/2012 @ 5:00:53 PM


C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

DATE ISSUED: 3/21/2012

1) 2) 3)

REVISION DATE:

DATE PRINTED: 3/21/2012 @ 5:00:54 PM

SHEET:

5 of 7

Jenny Burger CAD Technician

3/21/2012 @ 5:00:54 PM


C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

DATE ISSUED: 3/21/2012

1) 2) 3)

REVISION DATE:

DATE PRINTED: 3/21/2012 @ 5:00:54 PM

SHEET:

6 of 7

Jenny Burger CAD Technician

3/21/2012 @ 5:00:54 PM


3/21/2012 @ 5:00:54 PM

15'-8" 6068

5'

6068

Tall storage cabinet

15'-8" x 16'-2"

Low cabinet under TV

16'-2"

FAMILY

6'-2"

16'-2"

16'-2"

2'

New Bonus Room

1'-9"

15'-8" x 16'-2"

5'

9 1/4" I JOIST (12" O.C.)

Tall storage cabinet

6" STEP UP TO NEW FLOOR SYSTEM 9 1/4" BAND WITH SCREWS TO EXISTING BAND AND BLOCKING 5 1/2" LAG BOLTS INTO EXISTING RIM JOIST AND WALL STUDS. ONE BOLT ABOVE THE OTHER EVERY 2' O.C.

9068

5'-10"

9068

HALL

EXISTING FLOOR SYSTEM

HALL

15'-8" x 5'-10"

15'-8" x 5'-10" 15'-8"

15'-8"

2nd Floor 379 sq ft

1st Floor 379 sq ft (

'

1/2"

1/2"

MATCH EXISTING CROWN MOULDING

EXISTING HALL 2ND FLOOR

NEW BONUS ROOM 2ND FLOOR

5 1/2" LAG BOLTS INTO EXISTING RIM JOIST AND WALL STUDS. ONE BOLT ABOVE THE OTHER EVERY 2' O.C.

8'

7'-6"

9 1/4" BAND WITH SCREWS TO EXISTING BAND AND BLOCKING

MATCH EXISTING BASE MOULING

EXISTING FLOOR SYSTEM

Jenny Burger CAD Technician

18'-0 5/8"

1/2"

9 1/4"

COFFERED CEILING

1/2"

6"

9 1/4"

1/2"

18'-0 5/8"

1"

1/2"

3/4" TONGUE AND GROOVE OVER ADVANTEC SUBFLOOR

EXISTING HALL 1ST FLOOR

MATCH EXISTING CROWN MOULDING

FAMILY ROOM 1ST FLOOR

9'

9'-6"

9 1/4" I JOIST (12" O.C.)

MATCH EXISTING BASE MOULING

DATE ISSUED:

7/8"

REVISION DATE:

7/8"

C:\Users\Jenni\Desktop\ISSUU\24x36 Haviland 3.14.layout

3/21/2012

1) 2) 3)

DATE PRINTED: 3/21/2012 @ 5:00:54 PM

)

SHEET:

7 of 7


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.