HOUSE BRAMB

Page 1

BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION

PRELIMINARIES NOT FOR CONSTRUCTION

BUILDING HEIGHT: STORIES -WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE R LOT ( ACRES- SQUARE FEET)

LAYOUT PAGE TABLE SHEET # DESCRIPTION 1 TITLE SHEET 2 FLOOR PLAN BASEMENT LEVEL • International Building Code, 2012 Edition, with Georgia Amendments 3 FLOOR PLAN MAIN LEVEL (2015) 4 FURNITURE PLAN • International Residential Code, 2012 Edition, with Georgia 5 FURNITURE PLAN BASEMENT Amendments (2015) 6 OPTIONAL MAIN LEVEL FLOOR PLAN • International Fire Code, 2012 Edition, with Georgia Amendments 7 ROOF PLAN (2013) 8 ELEVATION 1 FRONT • International Plumbing Code, 2012 Edition, with Georgia 9 ELEVATION 2 LEFT SIDE Amendments (2015) 10 ELEVATION 3 REAR • International Mechanical Code, 2012 Edition, with Georgia 11 ELEVATION 4 RIGHT SIDE Amendments (2012) 12 DOOR/WINDOW PLAN/SCHEDULE BASEMENT • International Fuel Gas Code, 2012 Edition, with Georgia 13 DOOR/WINDOW PLAN/SCHEDULE MAIN LEVEL Amendments (2015) 14 ELECTRICAL LIGHTING PLAN BASEMENT • National Electrical Code, 2011 Edition, with no Georgia Amendments 15 ELECTRICAL LIGHTING PLAN MAIN LEVEL • International Energy Conservation Code, 20011 Edition, with Georgia 16 Supplements and Amendments (2011) (2012) 17 • 2012 NFPA 101 – Life Safety Code with state Amendments (2013) 18 19 20 21 22 23 24

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

Effective January 1, 2014 The following will be the State of Georgia's minimum Standard Construction Codes:

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

TITLE SHEET SCALE: 1/4" = 1' - 0"

SHEET: 1 OF 24


BY: J E NNY BUR GE R 73'-7"

8'-6"

3'-4 1/4"

8'-4 1/2"

3'-4 1/4"

6'

5'-5"

6'

EXACT NUMBER OF STAIRS TO BE DETERMINED BY GRADE

3'

16'-1"

3'

4'-10 3/4"

8'-0 1/2"

3'-7 1/4"

8'

2'-4 1/2"

2'-3 1/4" 2'-7 1/2"

8'-0 1/2"

COMPUTER DRAWING TECHNICIAN

2'-11"

2'-8 1/2"

5'

Elevation 8

E8 8'-3 1/2"

PRELIMINARIES NOT FOR CONSTRUCTION

15'-2 1/2"

11'-6"

15'-6"

1"

GARAGE

8'-3"

2'

2'-4"

5'-2"

4'-11"

15'-1"

2'-7"

228 sq ft

17'-5" 5'-2"

5'-

4'-8 3/4"

"

4'-

/4 REINFORCED CONCRETE SLAB

REINFORCED CONCRETE SLAB

15'-6"

1/16" PER FOOT SLOPE

7'

1/16" PER FOOT SLOPE

16'-6"

3'

/4

83

83

7'-8 1/4"

4'

7'-8 3/4"

4'-

"

UP

1/16" PER FOOT SLOPE

4'-7 1/2"

8'-3"

4'

10'-3"

5'

UP

FIREPLACE

16'-3"

12'-0 1/2"

5'-1"

6'-5 3/4"

22'-10 1/2"

3'-6"

6 sq ft

BEDROOM 5 266 sq ft

BATH

E10 53'-10"

CLOSET

CLOSET

12 sq ft

12 sq ft

5'-1"

6'-1"

6'-0 1/2"

5'

BEDROOM 4

13'-3 1/2"

UP

22'-1"

198 sq ft

16'-9"

U282196L

48'

38'-4"

WINDOWS MOUNTED 90" A.F.F. - TRANSOMS MOUNTED AT 107"

3'-6 1/2"

2'-5"

E5

1'-11 1/2"

BASEMENT LEVEL FLOOR PLAN - FIRST FLOOR BASEMENT IS UNFINISHED (DIMENSIONS ARE FROM STUD TO STUD OR CONCRETE)

2'-1"

Elevation 5

26'-4"

REINFORCED CONCRETE SLAB

BATH

5'-1"

18'-10"

66 sq ft

3'-6 1/2"

11'-9"

8"

CLOSET

24'-3"

5' 3'-6 1/2"

11'-9"

8"

8"

8"

6"

3'

CONFIRM IF THERE IS TO BE A TANKLESS WATER HEATER

3'-3 1/2"

16'-6"

59 sq ft

WH

8'-6"

15'-1"

7'-11"

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

1963 sq ft

Elevation 10

10'-6"

UNFINISHED BASEMENT CLNG HGHT: 10'

6'-3 1/4"

52 sq ft

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34")

42'-1"

DATE ISSUED:

73'-7"

11/23/2015

LIVING AREA 2958 sq ft

FLOOR PLAN BASEMENT LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 2 OF 24


Elevation 8

E8 73'-7" 6'

5'-5"

4'-2 1/2"

6'

16'-1" BUILT IN CABINETS 4'-6"

17'-11"

4'-10 3/4" BUILT IN CABINETS 4'-6"

FIREPLACE

3'-7 1/4"

2'-2"

5'-7 1/2"

E10 15'-9" 3'-6"

Elevation 10

B9

2'-11 1/2"

13'-11 1/2"

4'-9"

6'-8 1/2"

W3356 26 sq ft

FOYER CLNG HGHT: 12'

DINING ROOM CLNG HGHT: 12'

97 sq ft

212 sq ft

CLOSET 28 sq ft

BATH ROOM CLNG HGHT: 10'

STORAGE SHELVING 7 sq ft

3'-6 1/2" BEDROOM 2 CLNG HGHT: 10' 161 sq ft

LAUNDRY CLNG HGHT: 10'

23'-0 1/2"

4'

5'-8 1/2"

12'-5 1/2"

B3321

1'-9"

SB3321

3'-6 1/2"

13'

14'-2"

5'-1"

8'-6"

THE BEDROOMS AND BATH ARE THE SAME AS KAREN'S PLAN 77'-10"

38'-4"

BATH ROOM CLNG HGHT: 10'

2'-11 1/2"

4'-3"

BATH ROOM CLNG HGHT: 10'

8'-5"

4'-9"

5'-1"

11'-1 1/4"

1'-4 1/2"

CLOSET

18'-3 1/2"

4'-3"

9'-2"

141 sq ft

CONFIRM CABINETS OR HANGING ROD?? 11'-7 1/4"

3'-0 1/2"

46 sq ft

5'-8 1/2"

1'-7 1/2"

3'-1 1/2"

12" COLUMNSSTONE BASE (TYP)

13'-10 1/2"

HALL CLNG HGHT: 10'

U3318110L

HIS CLOSET CLNG HGHT: 10'

ATTIC ACCESS

HALL CLNG HGHT: 132" 30 sq ft

6'-11"

5'-6 1/2"

PANTRY

3'-6"

156 sq ft

23 sq ft

3'-6 1/2"

4'-1"

POWDER RM

MASTER BATH CLNG HGHT: 10'

COUNTER DEPTH 15'-2" REFRIGERATOR

17'-10"

LSB36R

4'-0 1/2" 35'-4"

3'-1" 7'-9 1/2"

10'-9 1/2"

U2422110

7'-5 1/2"

11'-10 1/2"

15'-3 1/2"

5'-6"

3'-3 1/2"

OPEN BELOW 50 sq ft

5"

2'-1"

1'-6"

5'

6'-4 1/2"

7" STEP DOWN

4'-7"

7'-6"

14'-5 1/2"

4'-0 1/2"

DN

2" STEP DOWN

3'

182 sq ft

13'

BEDROOM 3 CLNG HGHT: 10'

1/16" PER FOOT SLOPE

13'-5 1/2"

STAIRS DOWN

1/16" PER FOOT SLOPE

10'-7 1/2"

23'-8 1/2"

14'-9"

14'-6"

MAIN LEVEL FLOOR PLAN - SECOND FLOOR

7'-11"

24'

15'-1"

ATTIC ACCESS ATTIC ACCESS GARAGE 504 sq ft

(DIMENSIONS ARE FROM STUD TO STUD OR CONCRETE) BASE MOULDING: 8" CROWN MOULDING: 10" MAIN FLOORING: HARDWOOD - BATH FLOORING: TILE CASING: 1X4 WITH BACK BAND WINDOWS MOUNTED 90" A.F.F. - TRANSOMS MOUNTED AT 107" 4'-11"

7'

1/16" PER FOOT SLOPE

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

W3356

171 sq ft

28 sq ft

B9

1DB27

MICROWAVE

3'

23 sq ft

11'-4 3/4" BEDROOM 1 CLNG HGHT: 10'

CLOSET

WOOD HOOD + LINER. EXHAUST W41323 THROUGH ROOF

36" RANGE

FAMILY ROOM CLNG HGHT: 12' 427 sq ft

4'-7 1/4"

PRELIMINARIES NOT FOR CONSTRUCTION

11'-8" U3624110

1DB12

DW

22'-9 3/4"

3'-7"

B15L

B33

6'

BENCH

SHOWER

4'-11"

2'-4 1/4" 2'-6 3/4"

8'-7 3/4"

15'-6"

WASTE

1'-3"

4'-2 1/2" 30" APRON FRONT SINK-CENTER SINK IN ISLAND

41'-1"

3'-7"

86 sq ft

2" STEP DOWN

33'-3"

5'-5"

BLOCKING

15X24 NICHE'

Elevation 5

3'-8 3/4" 3'-8 3/4"

E5

9 sq ft

14'-2 1/2"

4'-4 1/2"

KEEPING ROOM CLNG HGHT: 10'

2'

2' 80 sq ft

181 sq ft

20'-2"

17'-0 1/2"

HER CLOSET CLNG HGHT: 10'

FIREPLACE

11'-8"

8'-6 1/2"

9'-3" 5'-9 1/2" 7'-8 1/2"

DECK

265 sq ft

291 sq ft

8'-2 1/2"

31'-5 1/2"

KEEPING ROOM CLNG HGHT: 10'

3'-2"

258 sq ft

1"

5'-1 1/2"

SCREEN PORCH

5'-

15'-3 1/2"

"

4'-

/4

91

83

/2

"

4'-

MASTER BDRM TRAY CLNG HGHT: 12'

1'-6"

COMPUTER DRAWING TECHNICIAN

16'-4"

15'-2"

2'-1"

BY: J E NNY BUR GE R

8'

15'-2"

3'-4 1/4"

7'

8'-4 1/2"

4'-10"

4'-3"

3'-4 3/4"

4'-10 1/4"

8'-5 1/2"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

21'-5"

4'-11"

E1

6'-3"

6'-3" 22'-4"

73'-7"

4'-11"

FLOOR PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 3 OF 24


BY: J E NNY BUR GE R

LSB36R

PANTRY

ATTIC ACCESS 1'-9"

U2422110

W3356

B9

15X24 NICHE'

1DB27

W41323

B15L

B9

B33

W3356

3'

PRELIMINARIES NOT FOR CONSTRUCTION

U3624110

1DB12

COMPUTER DRAWING TECHNICIAN

1'-9"

SB3321

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

CONFIRM WINDOW HEIGHTS AND PLACEMENTS IN BED ROOMS. WOULD YOU LIKE THE WINDOWS SHORTER OR TO GO TO THE RIGHT AND LEFT OF THE BEDS?

U3318110L

B3321

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

ATTIC ACCESS

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

FURNITURE PLAN SCALE: 1/4" = 1' - 0"

SHEET: 4 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

U282196L

PRELIMINARIES NOT FOR CONSTRUCTION

UP

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

WH

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

FURNITURE PLAN BASEMENT SCALE: 1/4" = 1' - 0"

SHEET: 5 OF 24


E3 73'-7" 6'

5'-5"

4'-2 1/2"

6'

16'-1" BUILT IN CABINETS 4'-6"

17'-11"

4'-10 3/4" BUILT IN CABINETS 4'-6"

FIREPLACE

3'-7 1/4"

2'-2" 86 sq ft

2' 2" STEP DOWN

7'-7" CLOSET 15 sq ft

3'-10"

68 sq ft

212 sq ft

4'-11 1/2"

7'-11 1/2"

DOWN BEDROOM 2 CLNG HGHT: 10' 177 sq ft

STAIRS DOWN

13'-7 1/2"

DINING ROOM CLNG HGHT: 12'

97 sq ft

3'-1"

STAIRS

3'-9 1/2"

FOYER CLNG HGHT: 12'

18'-2 1/2"

4'-3"

5'-8 3/4"

8'-6" 14'-2"

23'-0 1/2"

3'-10 1/2"

8'-11 1/4"

5'-7 1/2"

LAUNDRY

13'-1 3/4"

THESE TWO BEDROOMS ARE LARGER/WIDER IN THIS OPTION. IF YOU LIKE THIS OPTION, I WILL LAYOUT THE BEDROOMS IN THE BASEMENT.

CONFIRM IF THERE IS TO BE HANGING ROD OR WALL CABINETS 6'-2"

13'

1'-6"

5'

6'-4 1/2"

7" STEP DOWN

4'-7"

7'-6"

14'-5 1/2"

6 1/2"

3'

2" STEP DOWN

3'

182 sq ft

1/16" PER FOOT SLOPE

13'-5 1/2"

54 sq ft

BEDROOM 3 CLNG HGHT: 10'

77'-10"

HALL

101 sq ft

28 sq ft

5'

38'-4"

14 sq ft

4'-9"

ATTIC ACCESS

CLOSET

11'-7 1/4"

3'-0 1/2" 4'-3"

5'-8 1/2"

1'-7 1/2"

3'-1 1/2"

12" COLUMN STONE BASE (TYP)

U3318110L

8'-11"

5'-1 1/2" WATER CLOSET CLNG HGHT: 10'

30 sq ft

8"

4 sq ft

2'-5"

LINEN CLOSET

3'-9"

44 sq ft

BATH CLNG HGHT: 10' 69 sq ft

HALL CLNG HGHT: 132"

44'-4 3/4"

HIS CLOSET CLNG HGHT: 10'

9'-1 3/4" 5'-1"

7'-7"

3'-8 1/4"

4'-6 1/4"

E4

1/16" PER FOOT SLOPE

23'-8 1/2"

10'-7 1/2"

ATTIC ACCESS

14'-9"

14'-6"

MAIN LEVEL FLOOR PLAN - SECOND FLOOR

7'-11"

24'

15'-1"

GARAGE 504 sq ft

(DIMENSIONS ARE FROM STUD TO STUD OR CONCRETE) BASE MOULDING: 8" CROWN MOULDING: 10" MAIN FLOORING: HARDWOOD - BATH FLOORING: TILE CASING: 1X4 WITH BACK BAND WINDOWS MOUNTED 90" A.F.F. - TRANSOMS MOUNTED AT 107" 4'-11"

7'

1/16" PER FOOT SLOPE

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

W3356 W41323

15'-9 1/2"

11'-4 1/4"

3'-8 1/4"

156 sq ft

PANTRY

3'-5 1/2"

MASTER BATH CLNG HGHT: 10'

23 sq ft

2'-6 3/4"

2'-1"

15'-5" LSB36R

17'-9 1/2" 35'-4"

4'-1"

POWDER RM

7'-9 1/2"

10'-9 1/2"

U2422110

11'-10 1/2"

7'-5 1/2"

3'-1"

3'-9"

7'-8 1/2"

3'-8 1/2"

4'

239 sq ft

13'

U3624110

KITCHEN CLNG HGHT: 10'

15'-3 1/2"

ROOF

MICROWAVE

W3356

23 sq ft

191 sq ft

CLOSET

B9

B33

33'-2 1/2"

WOOD HOOD + LINER. EXHAUST

426 sq ft

3'

SHOWER

FAMILY ROOM CLNG HGHT: 12'

BEDROOM 1 CLNG HGHT: 10'

15 sq ft

B9 THROUGH

14'-3"

36" RANGE

22'-9 3/4"

3'-7" 8'-2 1/2"

1DB27

4'-4 1/2"

B15L

WASTE

1'-3"

BENCH

5'-5"

BLOCKING

15X24 NICHE'

5'-9 1/2"

E2

3'-7"

31'-5 1/2"

6'

4'-6" 30" APRON FRONT SINK-CENTER SINK IN ISLAND

2'-11 1/2"

5'-7 1/2"

34'-5" 1DB15

DW

3'

4'-4"

9 sq ft

2'-11 1/2"

2' 80 sq ft

FIREPLACE

20'-2"

17'-0 1/2"

HER CLOSET CLNG HGHT: 10'

2'-4 1/4" 2'-6 3/4"

BREAKFAST ROOM CLNG HGHT: 10'

11'-8"

3'-2"

VENTLESS FIRELPLACE CONFIRM THERE IS NO CHIMNEY

THESE TWO WALLS ARE NOT THE SAME LENGTH.

PRELIMINARIES NOT FOR CONSTRUCTION

7 3/4"

11'-8"

8'-6 1/2"

9'-3"

1'-6"

181 sq ft

4'-11"

DECK

265 sq ft

8'-7 3/4"

15'-6"

KEEPING ROOM CLNG HGHT: 10'

1"

5'-1 1/2"

258 sq ft

5'-

15'-3 1/2"

"

4'-

/4

91

83

/2

"

4'SCREEN PORCH

292 sq ft

2'-1"

COMPUTER DRAWING TECHNICIAN

16'-4"

15'-2"

MASTER BDRM TRAY CLNG HGHT: 12'

BY: J E NNY BUR GE R

8'

15'-2"

3'-4 1/4"

7'

8'-4 1/2"

4'-10"

4'-3"

3'-4 3/4"

4'-10 1/4"

8'-5 1/2"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

21'-5"

4'-11"

E1

6'-3"

6'-3" 22'-4"

73'-7"

4'-11"

OPTIONAL MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1' - 0"

SHEET: 6 OF 24


BY: J E NNY BUR GE R

2 10

12 : 12

:1

10 1/16 : 12

2

2

12

:1

:1

12

12 : 12

COMPUTER DRAWING TECHNICIAN

4 1/4 : 12

11 13/16 : 12

10 : 12

3 3/16 : 12

10 1/16 : 12 12 : 12

12 : 12 12 : 12

12 : 12

10 : 12

PRELIMINARIES NOT FOR CONSTRUCTION

12 : 12

12 : 12 12 : 12

11 9/16 : 12

ATTIC ACCESS

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

12 : 12

12 : 12

10 : 12

12 : 12

12 : 12 12 : 12

12 : 12 12 : 12

12 : 12 12 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

12 : 12

12 : 12

ATTIC ACCESS

ROOF PLAN OVERHANG: 18" FASCIA: 7 1/4" FRIEZE: 6" 30 YEAR ARCHITECTURAL SHINGLES

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015 12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

12 : 12

ROOF PLAN SCALE: 1/4" = 1' - 0"

SHEET: 7 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

ELEVATION 1

10 : 12

28'-8"

11 9/16 : 12

12 : 12

12 : 12

12 : 12

11'-5"

12 : 12

10'

12 : 12

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

D22

PLEASE LET ME KNOW WHERE YOU WOULD LIKE TO SEE STONE OR OTHER FINISHES. I STILL NEED TO ADD DOWN SPOUTS.

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

ELEVATION 1 FRONT SCALE: 1/4" = 1' - 0"

SHEET: 8 OF 24


BY: J E NNY BUR GE R

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

12 : 12 12 : 12 12 : 12 12 : 12

12 : 12

12 : 12

10'

1'-4"

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

11'-5"

12 : 12

24'

12 : 12

3'

NUMBER OF STEPS TO BE DETERMINED BY GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

ELEVATION 2 LEFT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 9 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

ELEVATION 3

10 : 12

4 1/4 : 12

3 3/16 : 12

12 : 12

10 1/16 : 12

12 : 12

22'

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

7'

1'-4"

1'-4"

3'

3'

9'-7"

10 : 12

12 : 12

D24

D21

4"

3'

D13

7"

11"

SEE ENGINEER'S DRAWINGS FOR FOOTING DIMENSIONS THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

ELEVATION 3 REAR SCALE: 1/4" = 1' - 0"

SHEET: 10 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

ELEVATION 4

12 : 12 11 13/16 : 12

10 : 12 10 : 12

12 : 12

10'-1"

3' 7" 3'

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

3'

D25

1'-4"

D25

12 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

ELEVATION 4 RIGHT SIDE SCALE: 1/4" = 1' - 0"

SHEET: 11 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

D24

UP W10

W10

W10

W10 D13 W10

PRELIMINARIES NOT FOR CONSTRUCTION

W10

W10

W04

W04

W10 D21

W10

D02

W10

D01 D03

D03

D04

W10

D04 D03

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

W10

D01

D01

NUMBER LABEL W04 2460DH W10 2860DH

WINDOW SCHEDULE QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTION HEADER 2 0 2460DH 28 " 72 " DOUBLE HUNG 2X6X32" (2) 12 0 2860DH 32 " 72 " DOUBLE HUNG 2X6X36" (2)

NUMBER D01 D02 D03 D04 D13 D21 D24

QTY 3 1 3 2 1 1 1

LABEL 2476 3076 4076 2876 3076 5076 9080

FLOOR 0 0 0 0 0 0 0

SIZE 2476 R IN 3076 L EX 4076 L/R IN 2876 L IN 3076 R EX 5076 L/R EX 9080

WIDTH 28 " 36 " 48 " 32 " 36 " 60 " 108 "

HEIGHT 90 " 90 " 90 " 90 " 90 " 90 " 96 "

MANUFACTURER COMMENTS

DOOR SCHEDULE DESCRIPTION HINGED INTERIOR DOOR HINGED INTERIOR DOOR DOUBLE HINGED INTERIOR DOOR HINGED INTERIOR DOOR HINGED EXTERIOR DOOR EXT. DOUBLE HINGED-TEXAS STAR DOOR GARAGE-GARAGE DOOR CHD14

HEADER 2X6X33" (2) 2X6X41" (2) 2X8X53" (2) 2X6X37" (2) 2X6X41" (2) 2X8X65" (2) 2X12X116" (2)

THICKNESS COMMENTS 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

DOOR/WINDOW PLAN/SCHEDULE BASEMENT SCALE: 1/4" = 1' - 0"

SHEET: 12 OF 24


W13

W13

BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

W09 D03

W07 W16

W19

W11

W11

W07

W07 W07

W11 W11

W11

W09

W07

D07

W03

W01

W11

W05

W15

W05

W16 W12

W15

CONFIRM WINDOW HEIGHTS/PLACEMENT ABOVE BEDS

D22

W11

W11 D11

D05

D01

D12

D14

PRELIMINARIES NOT FOR CONSTRUCTION

W07

D09

W04 W08

D06

D08

W02

D04

D02

D01

D05

D14

D04

D12 W02

W11

D10

CONFIRM WINDOW HEIGHTS/PLACEMENT ABOVE BEDS

D01

W11

D22 D13

W15

D15 W10

W14

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

D11

W06 W14

NUMBER W01 W02 W03 W04 W05 W06 W07 W08 W09 W10 W11 W12 W13 W14 W15 W16 W17 W19

LABEL 2013FX 2040DH 2060DH 4013FX 2460DH 2646DH 2813FX 4046FX 3013FX 7813FX 2860DH 5860MU 3613FX 7960MU 5013FX 5613FX 7913FX 5660MU

NUMBER D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11 D12 D13 D14 D15 D22 D25

LABEL 4076 2076 3076 2076 2476 2076 3076 2676 2876 2876 2076 2876 3076 2476 3076 5076 9080

W17

WINDOW SCHEDULE DESCRIPTION HEADER COMMENTS FIXED GLASS 2X6X28" (2) DOUBLE HUNG 2X6X28" (2) DOUBLE HUNG 2X6X28" (2) FIXED GLASS 2X8X52" (2) DOUBLE HUNG 2X6X32" (2) DOUBLE HUNG 2X6X34" (2) FIXED GLASS 2X6X36" (2) FIXED GLASS 2X8X52" (2) FIXED GLASS 2X6X40" (2) FIXED GLASS 2X10X96" (2) DOUBLE HUNG 2X6X36" (2) MULLED UNIT 2X8X71 1/2" (2) FIXED GLASS 2X6X46" (2) MULLED UNIT 2X10X97" (2) FIXED GLASS 2X8X64" (2) FIXED GLASS 2X8X70" (2) FIXED GLASS 2X10X97" (2) MULLED UNIT 2X8X70" (2) DOOR SCHEDULE QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTION HEADER 3 1 4076 L/R IN 48 " 90 " DOUBLE HINGED INTERIOR DOOR 2X8X53" (2) 1 1 2076 L IN 24 " 90 " HINGED INTERIOR DOOR 2X6X29" (2) 1 1 3076 R EX 36 " 90 " EXT. HINGED-TEXAS STAR DOOR 2X6X41" (2) 2 1 2076 L 24 " 90 " POCKET-INTERIOR DOOR 2X6X53" (2) 2 1 2476 R IN 28 " 90 " HINGED INTERIOR DOOR 2X6X33" (2) 1 1 2076 R 24 " 90 " POCKET-INTERIOR DOOR 2X6X53" (2) 1 1 3076 R IN 36 " 90 " HINGED EXTERIOR DOOR 2X6X41" (2) 1 1 2676 L IN 30 " 90 " HINGED INTERIOR DOOR 2X6X35" (2) 1 1 2876 R IN 32 " 90 " HINGED INTERIOR DOOR 2X6X37" (2) 1 1 2876 L 32 " 90 " POCKET INTERIOR DOOR 2X6X69" (2) 2 1 2076 R IN 24 " 90 " HINGED INTERIOR DOOR 2X6X29" (2) 2 1 2876 L IN 32 " 90 " HINGED INTERIOR DOOR 2X6X37" (2) 1 1 3076 L IN 36 " 90 " HINGED-CATALINA I DOOR 2X6X41" (2) 2 1 2476 L 28 " 90 " POCKET INTERIOR DOOR 2X6X61" (2) 1 1 3076 R EX 36 " 90 " HINGED INTERIOR DOOR 2X6X41" (2) 2 1 5076 L/R IN 60 " 90 " DOUBLE HINGED-TEXAS STAR DOOR 2X8X65" (2) 2 1 9080 108 " 96 " GARAGE-GARAGE DOOR CHD14 2X12X116" (2)

QTY 1 2 1 1 2 5 6 1 2 1 10 1 2 2 3 2 1 1

FLOOR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

SIZE 2013FX 2040DH 2060DH 4013FX 2460DH 2646DH 2813FX 4046FX 3013FX 7813FX 2860DH 5860 3613FX 7960 5013FX 5613FX 7913FX 5660

WIDTH 24 " 24 " 24 " 48 " 28 " 30 " 32 " 48 " 36 " 92 " 32 " 67 1/2 " 42 " 93 " 60 " 66 " 93 " 66 "

D25

HEIGHT 15 " 48 " 72 " 15 " 72 " 54 " 15 " 54 " 15 " 15 " 72 " 72 " 15 " 72 " 15 " 15 " 15 " 72 "

D25

THICKNESS COMMENTS 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4"

W06

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015 W06

W06

W06

DOOR/WINDOW PLAN/SCHEDULE MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 13 OF 24


BY: J E NNY BUR GE R

WOULD YOU LIKE ANY SCONCES ON THE POST?

UP

E07

COMPUTER DRAWING TECHNICIAN

E07

WP

E40

UP E46 E07 E56 E52

E14 E14 E40WP

E14

E07

E07

E46

E05

E46

E40

E14

E14

E52

WP

E14 E04

3

E52 E52 E52

E14

E14 E14

R E05 E56

R

E13

E46

E46

E11 E10

R

E14

E14

E12 R E05 SD

E52 E52 E52 E52

GFCI

E08 E46

E46

E52 E15 E14 E14 E52 DM

E06 E09 E14

E04

R

R

E05

E05

R DM 3

3

E05 E06 E52

E04

R E05

SD

ELECTRICAL SCHEDULE NUMBER QTY ATTACHED TO DESCRIPTION COMMENTS E01 1 WALL ELECTRICAL METER SOCKET E02 1 WALL ELECTRICAL PANEL E03 2 WALL 220V E04 3 WALL THREE WAY E05 13 CEILING RECESSED DOWN LIGHT 6 E06 2 WALL SINGLE POLE (SLIDING DIMMER) E07 5 WALL EXTERIOR SCONCE E08 2 WALL GFCI E09 2 WALL VANITY SCONCE E10 2 CEILING EXHAUST E11 2 CEILING RECESSED VAPOR LIGHT E12 2 CEILING BATH ROOM CEILING LIGHT E13 2 WALL QUADRUPLEX E14 19 WALL DUPLEX E15 2 CEILING SMOKE DETECTOR E40 3 WALL 220V WEATHERPROOF E46 12 CEILING 96" SURFACE MOUNTED [96W9D] E52 18 WALL SINGLE POLE E56 3 CEILING CLNG FAN + LIGHT

PRELIMINARIES NOT FOR CONSTRUCTION

R

E15

E52

E14

E46

E52 E52 E52 E52

E09

E56

R

E13

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

E46

UP E05

E14

R

GFCI

E08 E12

R E14E05

E46

E46

R

E10

E05E14

E14

R E11

R E05

E52

R

R

E05

E05

E46

WH E03

E03

E02

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

E01

EP

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

ELECTRICAL LIGHTING PLAN BASEMENT SCALE: 1/4" = 1' - 0"

SHEET: 14 OF 24


BY: J E NNY BUR GE R

CONFIRM ALL CABLE JACK AND TELEPHONE JACK LOCATIONS

COMPUTER DRAWING TECHNICIAN

E16 E25

R

E31

E31

R E27

E03

WP

E42 E41

C

E03

E31

R

E31

E24

R E03

E03

E25 E23

E38

DM

E38 E31 E31

E31

E41WP E31

R

R

R

R E25

E27 E03

E03

E03

E03

E31

E31

E21

E25 E25

R

E03

R

E27

E25

E31

E24

E31

R

E25

E23

E31 E23 E28

E03

E31 E31

DM

R E03

R E40 E03

R

E31

GFCI

E24 C

R

R

R

E03

E03

E03

E31

E31

R

E03

E03

E03

E03

E14

R

E09

M

3'

E03

R

R

GD

E11 E14

E38

E31

R

A

E35 E08

E04

R

R

E03

E03

E31 E38 E31

R

E23 GFCI

E03

E03

E03

E23 E25

DM

E17

E25

GFCI

E15

E03

E25 E31

E23

R

E03

E25

R

E03

ATTIC ACCESS

R

R

R

E03

E03

E03

GFCI

R

E26

E26

3 3

3

R

E26

E31

E31

E31

E03

E45

E43 E32

E03

E13

E45

E32

E35 E35

E35

E44

E18

E03

R

R

E02

E35

R

E25

R

E35

E03

E35

E12

E31

E03

E28

R

E25

E44

E03

E35

E31

E25

E31

E17

E32 E22

R

R

SD

H

E17

DM DM

E45

SD

E23 E27

E25

E19

R

O

GFCI

E25

E02

E10

E07

E23

DM

E25 E23 E32

DW

E14 SD

DM DM

R

R

E31

E25 E44

E31

R

GFCI

R

R

E03

E03

1'-9"

E25

E26

1'-9"

3 3

E25 E26

E18 E32

DM

E25

R E45

E03

GFCI

E23 E23

E25

E25

E25

E04

DM

E31

R

R

R

E03

E03

E03

R E31

R

E03

R

R

CW

E06

E03

E25

CD

E05

E03 E31

E25

E37

E24

E40

E25E25 E25E25 E25

R

R

E03

E03

DM

E17 R

E36

SD

E25 E17 E25

SD

C

E03 R E31

R

E03

E03

E38

E23

E01 E03

SD

E32

E40

GFCI

E17 E23 E25 DM

E38

DM

C E24

E42

E40

E42

E23

R E03 E31

E31 R

R E03

E03

E31 3

3

ELECTRICAL SCHEDULE ATTACHED TO DESCRIPTION COMMENTS CEILING 48" FL LAUNDRY RM WALL VANITY SCONCE MASTER CEILING RECESSED DOWN LIGHT 6 CEILING CLOSET LIGHT WALL CLOTHES DRYER WALL CLOTHES WASHER WALL DISHWASHER WALL GARBAGE DISPOSAL WALL MICROWAVE WALL OVEN FLOOR AIR SWITCH WALL REFRIGERATOR CEILING HALL LIGHT 1ST FL CEILING ISLAND PENDANT WALL HOOD W/ VENT WALL SPOTLIGHT 2 MOTION SENSOR CEILING SMOKE DETECTOR WALL VANITY SCONCE WALL VANITY SCONCE POWDER CEILING CHANDELIER BREAKFAST RM CEILING MASTER BATH CHANDELIER WALL SINGLE POLE (SLIDING DIMMER) WALL CABLE JACK WALL SINGLE POLE WALL THREE WAY FLOOR DUPLEX FLOOR GFCI WALL DUPLEX WALL GFCI UNDER CABINET LIGHT CEILING DININD RM CHANDELIER CEILING FOYER CHANDELIER CEILING CLNG FAN + LIGHT WALL QUADRUPLEX WALL 220V WEATHERPROOF WALL OLD WORLD SCONCE CEILING BATH RM LIGHT CEILING RECESSED VAPOR LIGHT CEILING EXHAUST CEILING 96" SURFACE MOUNTED [96W9D]

E03 E31 E31

E03 E31

E26

QTY 1 2 60 2 1 1 1 1 1 1 1 1 1 3 1 1 6 2 1 1 1 14 5 38 7 4 2 49 6 8 1 1 7 4 4 6 1 3 4 3

R

R

DN

NUMBER E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E21 E22 E23 E24 E25 E26 E27 E28 E31 E32 E35 E36 E37 E38 E40 E41 E42 E43 E44 E45 E47

E26

E31 WP

E42

E41 E25 E25

R E03

E31

E31

E31

PRELIMINARIES NOT FOR CONSTRUCTION

C

E38

E03 DME25

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

E25

WP

E41

R E03

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

E31 E47 E31

ATTIC ACCESS E42 E47 E31

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: E47

E31

11/23/2015 E31 E42

ELECTRICAL LIGHTING PLAN MAIN LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 15 OF 24


BY: J E NNY BUR GE R COMPUTER DRAWING TECHNICIAN

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

WOULD YOU LIKE THE HALL CEILING HGHT AT 144" TOO?

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

16 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

17 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

18 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

19 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

20 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

21 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

22 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

23 OF 24


BY: J E NNY BUR GE R

RESIDENTIAL SINGLE FAMILY OCCUPANCY NEW CONSTRUCTION BUILDING HEIGHT: STORIES-WOOD FRAME INTERIOR SQUARE FOOTAGE: IBC CODE LOT ( ACRES- SQUARE FEET)

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

SHEET:

SCALE: 1/4" = 1' - 0"

24 OF 24


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.