RESIDENCE ADDRESS ATLANTA, GEORGIA 30318
ADDRESS ATLANTA, GEORGIA 30318
INTERIOR KITCHEN RENOVATION
LAYOUT PAGE TABLE SHEET # DESCRIPTION 1 TITLE SHEET 2 EXISTING FLOOR PLAN 3 PROPOSED FLOOR PLAN 1 4 PERSPECTIVE 5 PERSPECTIVE 6 PERSPECTIVE 7 PERSPECTIVE 10 PERSPECTIVE 11 PERSPECTIVE 12 PERSPECTIVE 13 PERSPECTIVE 14 ELEVATIONS 15 PROPOSED PLAN 2 16 PERSPECTIVE 2 17 PERSPECTIVE 2 18 PERSPECTIVE 2 19 PERSPECTIVE 2 20 PERSPECTIVE 2 21 PERSPECTIVE 2 22 ELEVATIONS 2
RESIDENCE
Jenny Burger CAD Technician
INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
TITLE SHEET SCALE: 1/2" = 1' - 0"
SHEET: 1 OF 20
48'-2 1/2"
12'-2 1/2"
2'-1"
3068
DINING
15'-2 1/2"
153 sq ft
LIVING 335 sq ft
2'-10 1/2" 7'
HALL 44 sq ft
35'-9 3/8"
9"
RESIDENCE
SOFFIT
FLOORING: CARPET CLNG HGHT:99.875"
KITCHEN 181 sq ft FLOORING: TILE CLNG HGHT: 98 3/16" BAR PASS THROUGH
DW
FAMILY 498 sq ft
7'-4"
FLOORING: HARDWOOD VAULTED CEILING HEIGHT" 175"
3030FX
6 5/8"
INTERIOR KITCHEN RENOVATION
3'-5 1/2"
17'-4"
1'-3 1/8"
19'-6 7/8"
4055
6'-1 1/2"
Jenny Burger CAD Technician
4'-1 1/2"
UP
12'-3"
5'-1"
4068
ADDRESS ATLANTA, GEORGIA 30318
3'-6" 2'-10 1/2"
33711
20 sq ft
95.25 DOOR HGHT
1'-3 5/8"
3'-0 5/8"
LAUNDRY
5'-6 1/2"
6'-10 1/2"
NICHE' SHELVING
8'-0 3/8"
2855
2068
DN
9 STAIRS + LANDING DOWN
8'-4 1/2" 2 1/2"
3'-4"
6'-3 1/8"
33'-0 1/2"
2'-7"
2868
6250MU
6080MU
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
6250MU
9'-9"
LIVING AREA 2341 sq ft SHEET SIZE ARCH D (24" x 36")
36'-2 7/8"
DATE ISSUED:
1/15/2015
EXISTING FLOOR PLAN SCALE: 1/2" 3/8" = 1' - 0"
SHEET: 2 OF 20
2'-1"
3068
DINING 154 sq ft
LIVING 335 sq ft
2'-10 1/2" 7'-0 7/8" 2868
CONFIRM ALL APPLIANCE DIMENSIONS-UNDER CABINET LED LIGHTS COUNTER DEPTH REF. BOTTOM DRAWER-WOOD INTEGRATED PANELS
FLOORING: HARDWOOD CLNG HGHT:99.875"
9"
6'-1"
HEADER TO REMAIN
1'-3"
14'-9"
2'-2"
24" MICROWAVE DRAWER
PREP SINK
36" DUEL FUELWOOD HOOD
TRAY DIVIDER
2'-6"
CONFIRM SINK SIZE
1'-3"
3'-4 1/2"
NKBA RECOMMENDATIONS FOR TRAFFIC FLOW WIDTHS: 42" WIDE FOR 1 COOK 48" FOR 2 COOKS 36" MINIMUM
2'-2"
HOME OWNER REQUEST SYMMETRICAL SPACED CABINETRY TO THE RIGHT AND LEFT OF THE RANGE AND REFRIGERATOR, AND ISLAND TO BE CENTERED. SEE CABINET SHOP DRAWINGS FOR EXACT LAYOUT.
7'-7"
5' 12'-7 13/16"
2'-2"
2'-2 1/8"
3'
Jenny Burger CAD Technician
FLOORING: HARDWOOD CLNG HGHT: 98 3/16"
4068
YOU MAY WANT MORE SPACE ON THIS SIDE OF THE ISLAND FOR WORK/PREP AND TRAFFIC FLOW/DW TO OPEN WASTE PULL OUT, CUTLERY DIVIDER, APPLIANCE GARAGE
FAMILY 503 sq ft
ADDRESS ATLANTA, GEORGIA 30318
UP
DOOR WAY HGHT: 95.25"
45 sq ft
13'-7"
4'-6 1/2"
3668
KITCHEN
RESIDENCE
HALL
PHONE CHARGER
3'-4 1/2"
4055
20 sq ft
5'-3 5/8"
175 sq ft
3/4"
INSTALL HAND RAIL & INSTALL HARDWOODS ON STAIRS
8 sq ft
FLOORING: HARDWOOD VAULTED CEILING HEIGHT" 175"
INTERIOR KITCHEN RENOVATION
2 1/2"
LAUNDRY
10 1/2"
9'-8 1/2" 2855
6'-1 7/16"
PANTRY
DW
33'-0 1/2"
3'-4"
DN
9 STAIRS + LANDING DOWN
FILL NICHE'
4'-0 1/2"
RETURN CROWN ON ITSELF
3'-3"
WIDEN STAIR WELLHARDWOOD FLOORING
1'-3"
3030FX REMOVE SOFFIT THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
9'-9 1/8"
10'-6 1/8" SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PROPOSED FLOOR PLAN 1 SCALE: 1/2" = 1' - 0"
SHEET: 3 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 4 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 5 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 6 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 7 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 10 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 11 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 12 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE SCALE: 1/2" = 1' - 0"
SHEET: 13 OF 20
1'
7'-11 1/4"
3'-6"
Jenny Burger CAD Technician
3'-6"
3'
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE
8'-2 3/16"
INTERIOR KITCHEN RENOVATION
1' 7'-11 1/4"
8'-2 3/16"
1'-6" 3'
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
ELEVATIONS SCALE: 1/2" 3/4" = 1' - 0"
SHEET: 14 OF 20
2'-1"
3068
DINING 154 sq ft
LIVING 335 sq ft
2'-10 1/2" 7'-0 7/8" 2868
DW
6'-1"
HEADER TO REMAIN
1'-3"
14'-9"
12'-7 13/16"
36" DUEL FUELWOOD HOOD
9"
24" MICRO DRWR.
COUNTER DEPTH REF. BOTTOM DRAWER-WOOD INTEGRATED PANELS
PANTRY
503 sq ft YOU MAY WANT MORE SPACE ON THIS SIDE OF THE ISLAND FOR WORK/PREP AND TRAFFIC FLOW/DW TO OPEN
FLOORING: HARDWOOD VAULTED CEILING HEIGHT" 175"
INTERIOR KITCHEN RENOVATION
WASTE PULL OUT
FAMILY
2'-3"
NKBA RECOMMENDATIONS FOR TRAFFIC FLOW WIDTHS: 42" WIDE FOR 1 COOK 48" FOR 2 COOKS 36" MINIMUM
3/4" DW PANEL
7'-7"
RESIDENCE
5'
FLOORING: HARDWOOD CLNG HGHT:99.875"
HOME OWNER REQUEST ISLAND TO BE CENTERED, THE RANGE TO BE CENTERED WITH THE ISLAND, AND THE CABINETS TO THE RIGHT/LEFT RANGE TO BE SYMMETRICAL.
Jenny Burger CAD Technician
CONFIRM ALL APPLIANCE DIMENSIONS-UNDER CABINET LED LIGHTS
4068
ADDRESS ATLANTA, GEORGIA 30318
FLOORING: HARDWOOD CLNG HGHT: 98 3/16"
3'-1 1/2"
UP
DOOR WAY HGHT: 95.25"
45 sq ft
13'-7"
4'-6 1/2"
3668
175 sq ft
3'-1 1/2"
HALL
5'-3 5/8"
KITCHEN
CONFIRM SINK SIZE
4055
20 sq ft
3'-1 1/2"
INSTALL HAND RAIL & INSTALL HARDWOODS ON STAIRS
8 sq ft
PHONE CHARGER
8'-4 1/4"
LAUNDRY
10 1/2"
2855
6'-1 7/16"
PANTRY
9'-8 1/2" 2 1/2"
33'-0 1/2"
3'-4"
DN
9 STAIRS + LANDING DOWN
FILL NICHE'
4'-0 1/2"
RETURN CROWN ON ITSELF
3'-3"
WIDEN STAIR WELLHARDWOOD FLOORING
FILL WINDOW REMOVE SOFFIT THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
9'-9 1/8"
SHEET SIZE ARCH D (24" x 36")
10'-6 1/8"
DATE ISSUED:
2'
1/15/2015
37'-6 7/8"
PROPOSED PLAN 2 SCALE: 1/2" = 1' - 0"
SHEET: 15 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 16 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 17 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 18 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 19 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 20 OF 20
Jenny Burger CAD Technician
ADDRESS ATLANTA, GEORGIA 30318
RESIDENCE INTERIOR KITCHEN RENOVATION
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
PERSPECTIVE 2 SCALE: 1/2" = 1' - 0"
SHEET: 21 OF 20
1' 3'-6" 1'-6"
RESIDENCE
1'
INTERIOR KITCHEN RENOVATION
8'-2 3/16" 3'-6"
3'
7'-11 1/4"
ADDRESS ATLANTA, GEORGIA 30318
Jenny Burger CAD Technician
3'
8'-2 1/2" 1' 1'-6" 3'
8'
8'-2 1/2"
3'-6"
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ARCH D (24" x 36") DATE ISSUED:
1/15/2015
ELEVATIONS 2 SCALE: 1/2" = 1' - 0"
SHEET: 22 OF 20