RESIDENCE GEORGIA
Jenny Burger CAD Technician
INTERIOR/KITCHEN RENOVATION
KITCHEN RENOVATION
GEORGIA
LAYOUT PAGE TABLE SHEET NUMBER DESCRIPTION 1 COVER SHEET 2 EXISTING KITCHEN FLOOR PLAN 3 PROPOSED KITCHEN FLOOR PLAN 4 ELEVATI0NS 2 5 ELEVATION 4 6 ELEVATION 1 7 ELEVATION 3 8 OVEN CABINET CUT OUTS 9 ELEVATION 5 10 LIGHTING SCHEDULE 11 PERSPECTIVE 12 PERSPECTIVE 13 PERSPECTIVE
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
COVER SHEET
SHEET: 1 OF 13
FLOORING: HARDWOOD 180 1/4"
72" 45 5/8"
17"
49 1/2"
45 5/8"
33"
12 3/4"
2"
12 7/8"
30610 3087 10 3/8"
3387
17" Jenny Burger CAD Technician
38 7/8"
E3
KITCHEN 241 sq ft
88 3/4"
79 3/4"
82"
BREEZE WAY 98 sq ft
E1
GEORGIA
E4
5 5/8"
13 1/2" 42 1/2"
13 1/8"
54 5/8"
3387
39"
30610
36"
3087
E6
20"
203 3/8"
E2
196 3/8"
E5
37610 3787 9"
45 5/8"
50 1/2"
46"
33"
KITCHEN RENOVATION
30610
3087
53"
9 1/4"
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
EXISTING KITCHEN FLOOR PLAN SCALE: 1/4" = 1' - 0"
SHEET: 2 OF 13
PROPOSED GALLOWAY FLOOR PLAN
34 3/4"
18 5/8"
CEILING HEIGHT APPROX: 135" BASE TRIM: 9 7/8" LINTEL: 8 1/2" WINDOW TRIM: 6 1/4" INTERIOR DOOR TRIM: 5 3/4" EXTERIOR DOOR TRIM: 6" DOOR HEIGHT: 82" FLOORING: HARDWOOD 180 1/4"
78"
72"
49 1/2"
45 5/8"
45 5/8"
33"
24 5/8"
6" FULL HEIGHT CABINETS ON RIGHT SIDE INSIDE THE PANTRY FOR SPICES
27"
17"
FURR OUT BRICK WALL WITH 1" AIR SPACE TO ATTACH CABINETRY. 80 3/4" 1 1/2"
TWO TRAY DIVIDERS IN TOP OF CABINET.
3 5/8"
54 5/8"
21"
19 1/2"
30"
U302496
TV 2"
5 5/8"
13 1/8"
238 sq ft 42 1/2"
W1842R 4DB21
3/4"
24"
44"
KITCHEN
37610 3787 7"
13 1/2"
48"
2DB36
15" 24"
3387
39"
30610
36"
3DB24
1DB15 4DB24
E1 WASTE PULL OUT
3087
36"
E4
16"
24"
36"
SB36
30"
79 3/4"
82"
98 sq ft
20"
203 3/8"
BREEZE WAY
ARCH MANTEL WHAM
196 3/8"
15" E5
Jenny Burger CAD Technician
53"
37"
BROOM CLOSET. FULL HEIGHT FILLER.
22"
W1842L
24"
24"
E2
3DB24UF2596
15"
DW
12" 12"
7 1/4"
E3
3/4" 24"
3/4"
15"
1 1/2"
54 3/8"
TWO ROLL OUT TRAYS IN CABINET ABOVE REFRIGERATOR.
KITCHEN RENOVATION
36"
3387
38 7/8"
30610
2"
GEORGIA
6"
REF.
3087
8 3/4"
42"
18"
3 DECORATIVE SIDE PANELS
9 1/4"
W372227
10 3/8"
15"
3"
12 7/8"
30610
24"
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
9"
45 5/8"
50 1/2"
46"
1/29/2015
33"
PROPOSED KITCHEN FLOOR PLAN SCALE: 1/4" = 1' - 0"
SHEET: 3 OF 13
96"
GEORGIA
Jenny Burger CAD Technician
ELEVATION 2
34 1/2"
34 1/2"
2"
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
4"
WASTE PULLOUT
KITCHEN RENOVATION
3 CM COUNTER THICKNESS
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
ELEVATI0NS 2 SCALE: 1/2" = 1' - 0"
SHEET: 4 OF 13
GEORGIA
34 1/2"
KITCHEN RENOVATION
4"
36"
3CM COUNTER THICKNESS
Jenny Burger CAD Technician
ELEVATION 4
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
ELEVATION 4 SCALE: 1/2" = 1' - 0"
SHEET: 5 OF 13
ELEVATION 1
18"
TALL FILLER FOR COUNTER TOP RETURN
BASE FILLER
Jenny Burger CAD Technician
GEORGIA
KITCHEN RENOVATION
48 7/16"
18" 4"
36"
12 1/4" 6"
49"
7 1/16"
72 7/8"
3 CM COUNTER THICKNESS
2.75" SEPARATION
96"
30"
135"
51"
42"
22"
48"
3"
SEE OVEN DETAIL DRAWING FOR CUT OUTS.
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
ELEVATION 1 SCALE: 3/8" = 1' - 0"
SHEET: 6 OF 13
ELEVATION 3
GEORGIA
KITCHEN RENOVATION
74" 34 1/2" 36"
TO TOP OF HINGE.
4"
72 7/8"
96"
18" 96" 110 3/4"
135"
42"
22"
2 ROLL OUT SHELVES
Jenny Burger CAD Technician
6" DEEP SPICE CABINET
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
ELEVATION 3 SCALE: 1/2" = 1' - 0"
SHEET: 7 OF 13
30" OVEN CABINET CUT OUTS OVER ALL HEIGHTS
GEORGIA
Jenny Burger CAD Technician
48 7/16"
7/16"
29 1/16"
THERMADOR 24" CONVECTION MICROWAVE MCES WITH 30" TRIM KIT OVERALL WIDTH: 23 7/8" OVERALL HEIGHT 14 13/16" (A MINIMUM OF 3/4" IS RECOMMENDED BETWEEN MICROWAVE AND LOWER WALL OVEN. CUTOUT WIDTH: 28 7/16" CUTOUT HEIGHT: 19 7/8" TRIM KIT: 29 3/4"W X 20 1/2" TALL
THERMADOR 30-INCH SINGLE OVEN POD301J Min. Cabinet Width 30" Min. Cabinet Depth 24" Cutout Width 28 1/2" Cutout Height 28 1/4" Trim Overlaps (top - bottom - sides) 13/16" – 1/8" – 5/8"
THERMADOR WARMING DRAWER 30-INCH CONVECTION WDC30JP Front Panel Width 29 3/4" Front Panel Height 11 1/4" Front Panel Depth 1 5/8" (includes gasket) Cutout Width 28 1/2" Cutout Height 10"
Cutout Depth 23"
KITCHEN RENOVATION
96"
20 1/2"
TRIM KIT 13/16"
28 1/2"
11 1/4"
28 1/2"
4"
28 1/4" 1" MINIMUM
1 1/2" 10"
45 7/8"
3/4" MINIMUM IF OVEN IS BELOW
28 7/16"
1 1/2"
19 7/8"
29 15/16"
CUT OUT HEIGHTS
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
30"
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
OVEN CABINET CUT OUTS SCALE: 1/2" = 1' - 0"
SHEET: 8 OF 13
GEORGIA
KITCHEN RENOVATION
4" 3/4" 34 1/2"
96"
Jenny Burger CAD Technician
ELEVATION 5
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
ELEVATION 5 SCALE: 1/2" = 1' - 0"
SHEET: 9 OF 13
CL 2'-6"
CL 4'-2 1/16"
CL 4'-2 1/16"
4'-6"
2'-6"
3DM
R
CL
R
R
R
5'-8 3/16"
GFCI PLUG MOLD
GFCI DW
B CL
CT
R DW DISPOSER
H
5'-8 3/16"
A - NOT TO SCALE GFCI
2'-6"
R
PLUG MOLD
R
A
3DM DM DM
LIGHTING SCHEDULE CODE DESCRIPTION COMMENTS SINGLE POLE (SLIDING DIMMER) THREE WAY (SLIDING DIMMER) RECTANGULAR A 5" RECESSED CANS IC REMODEL HOUSING PLUG MOLD. B HANGING PENDANT GFCI DISHWASHER VENT RECEPTACLE GAS COOKTOP MICROWAVE RECEPTACLE REFRIGERATOR RECEPTACLE OVEN RECEPTACLE DISPOSER
M M O
KITCHEN RENOVATION
R
CL
GFCI
GEORGIA
GFCI
QTY 2 2 3 8 2 21 3 1 1 1 1 1 1 1
Jenny Burger CAD Technician
R
MODEL
EL55RICA
THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
LIGHTING SCHEDULE SCALE: 1/4" = 1' - 0"
SHEET: 10 OF 13
Jenny Burger CAD Technician
GEORGIA
KITCHEN RENOVATION THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
PERSPECTIVE
SHEET: 11 OF 13
Jenny Burger CAD Technician
GEORGIA
KITCHEN RENOVATION THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
PERSPECTIVE
SHEET: 12 OF 13
Jenny Burger CAD Technician
GEORGIA
KITCHEN RENOVATION THE HOME OWNER, DESIGNER, AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE Letter (8½" x 11") DATE ISSUED:
1/29/2015
PERSPECTIVE
SHEET: 13 OF 13