KITCHEN VAN B

Page 1

BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATION

LAYOUT PAGE TABLE DESCRIPTION TITLE SHEET EXISTING FLOOR PLAN MAIN LEVEL PROPOSED FLOOR PLAN MAIN LEVEL PROPOSED KITCHEN & FAMILY ROOM FLOOR PLAN ELEVATIONS 1 & 2 ELEVATION 3 ELEVATIONS 5 & 6 EXISTING EXTERIOR ELEVATION 1 FRONT EXISTING EXTERIOR ELEVATION 2 LEFT SIDE EXISTING EXTERIOR ELEVATION 3 REAR EXISTING EXTERIOR ELEVATION 4 RIGHT SIDE PROPOSED EXTERIOR ELEVATION 1 PROPOSED EXTERIOR ELEVATION 2 PROPOSED EXTERIOR ELEVATION 3 PROPOSED EXTERIOR ELEVATION 4 EXISTING ROOF PLAN PERSPECTIVE PERSPECTIVE PERSPECTIVE PERSPECTIVE PERSPECTIVE PERSPECTIVE ELECTRICAL LIGHTING PLAN HOOD

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

SHEET # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

• International Building Code, 2012 Edition, with Georgia Amendments (2015) • International Residential Code, 2012 Edition, with Georgia Amendments (2015) • International Fire Code, 2012 Edition, with Georgia Amendments (2013) • International Plumbing Code, 2012 Edition, with Georgia Amendments (2015) • International Mechanical Code, 2012 Edition, with Georgia Amendments (2012) • International Fuel Gas Code, 2012 Edition, with Georgia Amendments (2015) • National Electrical Code, 2014 Edition, with no Georgia Amendments • International Energy Conservation Code, 20011 Edition, with Georgia Supplements and Amendments (2011) (2012) • 2012 NFPA 101 – Life Safety Code with state Amendments (2013)

COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

Effective January 1, 2014 The following will be the State of Georgia's minimum Standard Construction Codes:

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

TITLE SHEET SCALE: 1/8" = 1' - 0"

SHEET: 1 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

E3

EXISTING FLOOR PLAN MAIN LEVEL FLOORING HARDWOODS DECK 338 SQ FT

4 1/2" 7 1/4"

4 1/2"

4 1/2"

16'-6 9/16"

21'-10 9/16"

PRELIMINARIES NOT FOR CONSTRUCTION

2'-10 9/16"

DECK

2845DH

5068

5068

2'-8"

5'-11 1/4"

266 SQ FT

223 SQ FT

PANTRY

STAIRS 30 SQ FT

DOWN

3'-10"

4'-5 3/8" 1'-3"

2835DH

2839DH 2839DH

20'-11 5/16"

2839DH

329 SQ FT

3068

5 5/8"

2839DH

11"

2835DH

2'-3 1/4"

2836DH

DINING

25'-6"

BATH 52 SQ FT

OFFICE 176 SQ FT

2445DH

2836DH

2839DH

6'-0 7/8" 9'-10 7/8"

2'-1"

2668

2'-7" 2'-10"

2'-2"

2'-9"

ENTRY

FLOORING: TILE

2'-7 3/4" BATH

E4

8'-5 1/16"

44 SQ FT

180 SQ FT

26 SQ FT

12'-11"

31068

2'-8 1/2"

17'-2 1/4"

4 1/2"

2668

2068

FLOORING: TILE

2'-4"

2668

21'-1 7/8"

5'-1"

13'-4 9/16"

13 SQ FT

4 1/2" 11'-9"

HALL 111 SQ FT

SHOWER

BEDROOM

21068

11 3/16"

4068

2468

PORCH

5'-8"

E2

4'-4 1/2"

3'-1 1/4"

2668

13'-5 3/8"

9 SQ FT

5'-2 1/4"

4 1/2"

OPEN RAIL

3'-5 1/8"

UP

4068

1'-1 1/2"

2836DH

4068

3'-4"

3'-1 1/4"

1/16" 4 7/16" 1/16"

45 SQ FT

5068

2'-8 7/16" CLOSET

3'-5 1/8"

CLOSET

11'-8 13/16"

2'-10 9/16"

4 1/2"

2668

4'-6 7/16"

4 1/2"

3'-5 7/8"

4 1/2"

5'-6" 4 1/2"

2'-8"

4 1/2"

TOEKICK REGISTER 4 1/2"

CEILING HEIGHT: 99"

2668

4'-4"

6'-0 1/2"

4068

1'-0 7/16"

2845DH

CEILING HEIGHT: 96 11/16"

9'-7"

12'-2"

FAMILY ROOM

KITCHEN

12'-2"

12'-4 1/4"

170 SQ FT

17 SQ FT

4'-5 1/2"

DESK

BEDROOM

CLOSET

5068

4'-3 1/2"

3'-2"

4068

11'-2 15/16"

17 SQ FT

2'-6 15/16"

5 3/4"

DOUBLE OVEN

CLOSET

5068

16'-1 7/8"

2845DH

353 SQ FT

2839DH

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

3'-1 15/16"

13'-5 3/8"

4'-1 1/2"

5'-4"

3'

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

4 1/2"

13'-5 3/8"

7'-6 7/8"

LIVING AREA 1899 SQ FT

E1

SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING FLOOR PLAN MAIN LEVEL SCALE: 1/8" = 1' - 0"

SHEET: 2 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PROPOSED FLOOR PLAN MAIN LEVEL FLOORING HARDWOOD 13'-5 3/8"

7 1/4"

2'-10 9/16"

4 1/2"

DECK

16'-6 9/16"

275 SQ FT

21'-10 9/16"

REMOVE WALL AND RECESS HEADER INTO CEILING IF POSSIBLE.

REMOVE DOORS & REPLACE WITH A WINDOW. 4740MU 8 1/2" 4'-8"

4'-5 1/2" 5068 2446DH

FILL DOOR

1'

4'-5 1/2" 2'

2'

2'-3"

2'-8"

2446DH

RELOCATE REGISTER USE RECESSED METAL L BRACKETS FOR COUNTER SUPPORT

13'-4"

CLOSET

24" MICROWAVE + TRIM KIT 30" OVEN TOEKICK REGISTER

E1

1'-3"

E3

E6

UP

9 SQ FT

4'-9 3/4" 21068

2'-8 7/16" CLOSET

3'-4"

NEW DOOR TO MATCH CABINETRY

4068

OPEN RAIL 11'-9"

HALL

2668

8'-5 1/16"

20'-9 3/8"

OFFICE

2068

329 SQ FT

DOWN

1'-3" 2835DH

2835DH

2'-3 1/4"

2836DH

2445DH

2836DH

11" 5 5/8"

2'-7" 2'-10"

2'-2"

3068

2839DH

BATH 26 SQ FT

3'-10"

4'-5 3/8"

2'-7 3/4"

FLOORING: TILE

DINING

25'-6"

STAIRS 30 SQ FT

FLOORING: TILE

2'-1"

2668

BATH 52 SQ FT

2839DH

176 SQ FT

180 SQ FT

20'-11 5/16"

ENTRY 44 SQ FT

5'-1"

13 SQ FT

2839DH

SHOWER

BEDROOM

31068

2'-8 1/2"

PORCH

2839DH

3'-4"

309 SQ FT

2'-7"

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

UP 13'-5 3/8"

4'-1 1/2"

5'-4"

3'

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

2668

17'-2 1/4"

2468

13'-4 9/16"

12'-11"

111 SQ FT

13'-5 3/8"

2'-9"

1'-1 1/2"

2836DH

4068

3'-1"

2023SC

4' THIS REGISTER WILL NEED TO BE RELOCATED.

6 11/16" 4068

INSTALL NEW WINDOW MOUNT THE TOP OF THIS WINDOWS AT 84" AFF

2839DH

1/16" 4 7/16" 1/16"

44 SQ FT

The beverage center: the fridge will recess into the wall 4" 5068

11'-8 13/16" 3'-5 1/8"

2668

4'-6 7/16"

CLOSET

255 SQ FT

1' 1'-9"

3 1/4" 2'-10 9/16"

FAMILY ROOM EXISTING CEILING HEIGHT: 99"

36" SUB ZERO

FLUSH HEARTH

12'-2"

E5 2'

2'-4"

CLOSET

5'-4"

E2

2668

36" GAS RANGE

8'-1 1/4"

4'-6"

225 SQ FT

17 SQ FT

3'-5 7/8"

SEE MANUFACTURER'S SPECIFICATIONS FOR FIREBOX CUT OUT DIMENSIONS.

KITCHEN EXISTING FINISHED CEILING HEIGHT: 96 11/16"

3'-3"

4068

1'-0 7/16"

2845DH

168 SQ FT

E4

VENTAHOOD BH234PSLD W: 34 3/8" X 22 1/2" D

BEDROOM

1'-10"

FILL WINDOW

12'-4 1/4"

11'-2 15/16"

2'-3" 2'

6'

17 SQ FT

9'-7"

INSTALL NEW WINDOW MOUNT THE TOP OF THIS WINDOWS AT 84" AFF

7'

4068

DW

3'-1"

FILL WINDOW

REMOVE DOOR AND REPLACE WITH WINDOW

FLOATING SHELVES

2023SC

2845DH

10"

2845DH

PRELIMINARIES NOT FOR CONSTRUCTION

EXISTING DECK

7'-2 3/8"

LIVING AREA 1886 SQ FT

SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED FLOOR PLAN MAIN LEVEL SCALE: 1/8" = 1' - 0"

SHEET: 3 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PROPOSED FLOOR PLAN MAIN LEVEL FLOORING HARDWOOD 4 1/2"

DECK

16'-6 9/16"

275 SQ FT

21'-10 9/16"

PRELIMINARIES NOT FOR CONSTRUCTION

7 1/4"

EXISTING DECK

REMOVE WALL AND RECESS HEADER INTO CEILING IF POSSIBLE.

REMOVE DOORS & REPLACE WITH A WINDOW. 4740MU 8 1/2" 4'-8"

4'-5 1/2" FLOATING SHELVES

5068 2446DH

2446DH

2023SC

4'-5 1/2" 2'

2'

2'-3"

1'

10"

FILL DOOR

RELOCATE REGISTER

DW USE RECESSED METAL L BRACKETS FOR COUNTER SUPPORT

INSTALL NEW WINDOW MOUNT THE TOP OF THIS WINDOWS AT 84" AFF

7'

13'-4"

3'-1"

FILL WINDOW

REMOVE DOOR AND REPLACE WITH WINDOW

1'-3"

E3

E6

255 SQ FT

The beverage center: the fridge will recess into the wall 4"

INSTALL NEW WINDOW MOUNT THE TOP OF THIS WINDOWS AT 84" AFF

5068

11'-8 13/16"

NEW DOOR TO MATCH CABINETRY

4' THIS REGISTER WILL NEED TO BE RELOCATED.

2839DH

9 SQ FT

4'-9 3/4" 21068

3'-5 1/8"

2'-8 7/16" CLOSET

6 11/16" 4068

OPEN RAIL HALL

3'-1"

1' 1'-9"

3 1/4"

2023SC

EXISTING CEILING HEIGHT: 99"

36" SUB ZERO

UP

FAMILY ROOM

11'-9"

12'-11"

8'-5 1/16"

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

E1

2'

FLUSH HEARTH

2'-4"

24" MICROWAVE + TRIM KIT 30" OVEN TOEKICK REGISTER

E5

2668

E2

12'-2"

EXISTING FINISHED CEILING HEIGHT: 96 11/16"

3'-3"

36" GAS RANGE

5'-4"

225 SQ FT

6'

SEE MANUFACTURER'S SPECIFICATIONS FOR FIREBOX CUT OUT DIMENSIONS.

KITCHEN 8'-1 1/4"

4'-6"

VENTAHOOD BH234PSLD W: 34 3/8" X 22 1/2" D

1'-10"

E4

FILL WINDOW

12'-4 1/4"

2'-3" 2'

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED KITCHEN & FAMILY ROOM FLOOR PLAN SCALE: SCALE:1/8" 1/4"==1'1'- -0"0"

SHEET: 4 OF 24


5"

BY: JENNY BURGER

4'-6" 3'

PRELIMINARIES NOT FOR CONSTRUCTION KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

1'-6"

8'-0 11/16"

3 1/2"

5'-6"

ELEVATION 2

4'-6"

1'-3"

9"

3"

3'-2"

WOOD HOOD

7'-6"

1"

3'-4 1/2"

1'-1"

3"

5"

1'-6"

3'

4'-6"

8'-0 11/16"

1'-6"

2'-4 7/8"

7'

ELEVATION 1

7'-6"

3'-2"

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

ELEVATIONS 1 & 2 SCALE: SCALE:1/8" 1/2"==1'1'- -0"0"

SHEET: 5 OF 24


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

1"

VENTAHOOD BH234PSLD W: 34 3/8" X 22 1/2" D

4'

9"

3"

1'-1"

3"

1"

COMPUTER DRAWING TECHNICIAN

6'-8"

7'-5"

1'-3"

WOOD FLOATING SHELVES

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

WASTE PULL OUT

ELEVATION 3

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

ELEVATION 3 SCALE: SCALE:1/8" 1/2"==1'1'- -0"0"

SHEET: 6 OF 24


5"

BY: JENNY BURGER

8'-0 11/16"

PRELIMINARIES NOT FOR CONSTRUCTION

ELEVATION 6

3'

4'-6"

MOUNT THE TOP OF THESE WINDOWS AT 84" AFF

4'

SEE MANUFACTURER'S SPECIFICATIONS FOR FIREPLACE CUT OUT DIMENSIONS.

3' 5 1/2"

ELEVATION 5

2023SC

6'-7"

2023SC

FLUSH HEARTH

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

1'-6"

7'-6"

3'-2"

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

ELEVATIONS 5 & 6 SCALE: SCALE:1/8" 1" ==1'1'- -0"0"

SHEET: 7 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

INTERIOR CEILING HEIGHT

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

8'

8'

PRELIMINARIES NOT FOR CONSTRUCTION

EXISTING FRONT ELEVATION 1

INTERIOR CEILING HEIGHT

GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING EXTERIOR ELEVATION 1 FRONT SCALE: 1/8" = 1' - 0"

SHEET: 8 OF 24


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

INTERIOR CEILING HEIGHT

GRADE

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

3'

INTERIOR CEILING HEIGHT

3'

8'

8'

EXISTING LEFT SIDE ELEVATION 2

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING EXTERIOR ELEVATION 2 LEFT SIDE SCALE: 1/8" = 1' - 0"

SHEET: 9 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

EXISTING REAR ELEVATION 3

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING EXTERIOR ELEVATION 3 REAR SCALE: 1/8" = 1' - 0"

SHEET: 10 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

INTERIOR CEILING HEIGHT

INTERIOR CEILING HEIGHT

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

8'

8'

PRELIMINARIES NOT FOR CONSTRUCTION

EXISTING RIGHT SIDE ELEVATION 4

GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING EXTERIOR ELEVATION 4 RIGHT SIDE SCALE: 1/8" = 1' - 0"

SHEET: 11 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

INTERIOR CEILING HEIGHT

INTERIOR CEILING HEIGHT

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

8'

8'

PROPOSED FRONT ELEVATION 1

GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED EXTERIOR ELEVATION 1 SCALE: 1/8" = 1' - 0"

SHEET: 12 OF 24


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

3'

INTERIOR CEILING HEIGHT

GRADE

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

INTERIOR CEILING HEIGHT

3'

8'

8'

PROPOSED LEFT SIDE ELEVATION 2

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED EXTERIOR ELEVATION 2 SCALE: 1/8" = 1' - 0"

SHEET: 13 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

PROPOSED REAR ELEVATION 3

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED EXTERIOR ELEVATION 3 SCALE: 1/8" = 1' - 0"

SHEET: 14 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

INTERIOR CEILING HEIGHT

INTERIOR CEILING HEIGHT

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

8'

8'

PRELIMINARIES NOT FOR CONSTRUCTION

PROPOSED RIGHT SIDE ELEVATION 4

GRADE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PROPOSED EXTERIOR ELEVATION 4 SCALE: 1/8" = 1' - 0"

SHEET: 15 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

PRELIMINARIES NOT FOR CONSTRUCTION

12 : 12 12 : 12

12 : 12

EXISTING ROOF PLAN

12 : 12

11 11/16 : 12

12 : 12

6 7/16 : 12

12 7/16 : 12

3 : 12

9 7/16 : 12

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

12 1/4 : 12

12 : 12

3 : 12

9 7/16 : 12

9 7/16 : 12

5 3/16 : 12

4 5/16 : 12

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

EXISTING ROOF PLAN SCALE: 1/8" = 1' - 0"

SHEET: 16 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 17 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 18 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 19 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 20 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 21 OF 24


BY: JENNY BURGER

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

PERSPECTIVE SCALE: 1/8" = 1' - 0"

SHEET: 22 OF 24


BY: JENNY BURGER

ELECTRICAL SCHEDULE GFCI

GFCI

GFCI

GD

DM

GFCI

NUMBER

3DM

R4 R4

GFCI

R4

R4

R4

R

R

R4

CENTER LIGHT OR CHANDELIER?

CT

R4 R4

H

PLUG MOLD.

GFCI

R4 R4

R4

GFCI

R

R

R4

R4 R4

CO/SD

M

O

GFCI

R

R

R

DM

DM

DM 3DM

TV

E01 E02 E03 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23

QTY ATTACHED TO DESCRIPTION 2 3 14 1 1 6 2 1 1 1 2 1 5 8 1 1 2 14 1 1 5 1

CEILING FLOOR FLOOR CEILING WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL CEILING CEILING CEILING CEILING FLOOR

ARTS & CRAFTS PENDANT BUFFET LAMP TUBE TRIPOD FLOORLAMP MINI-SHADE 6 LIGHT CHANDELIER SINGLE POLE (SLIDING DIMMER) THREE WAY (SLIDING DIMMER) GARBAGE DISPOSAL GAS COOKTOP HOOD W/ VENT SINGLE POLE TELEVISION JACK DUPLEX GFCI MICROWAVE OVEN REFRIGERATOR RECESSED DOWN LIGHT 4 MEDITERRANEAN CO/SMOKE DETECTOR RECESSED DOWN LIGHT 6 SINGLE RECEPTACLE

DM DM

UP

COMMENT S

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

NO OUTLETS AND SWITCHES ON BACKSLASHES. SOP ALL OUTLETS AND SWITCHES TO BE MOUNTED UNDER THE UPPER CABINET UNLESS OTHERWISE STATED.

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

ELECTRICAL LIGHTING PLAN SCALE: 1/8" = 1' - 0"

SHEET: 23 OF 24


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

3"

VENTAHOOD BH234PSLD W: 34 3/8" X 22 1/2" D

7'-5"

1'-3"

WOOD FLOATING SHELVES

PRELIMINARIES NOT FOR CONSTRUCTION

4'

9"

3"

1'-1"

1"

MOUNT THIS WINDOW AT 88" AFF

1'-6" 3'

4'-6"

5'-6"

KITCHEN AND FAMILY ROOM RENOVATION- SINGLE FAMILY INTERIOR RENOVATIO

3 1/2"

8'-0 11/16"

4'-6"

1'-3"

9"

3"

3'-2"

WOOD HOOD

7'-6"

1"

3'-4 1/2"

1'-1"

3"

5"

WASTE PULL OUT

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI B (11" x 17") DATE ISSUED:

1/23/2018

HOOD SCALE: SCALE:1/8" 1/2"==1'1'- -0"0"

SHEET: 24 OF 24


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.