jessica alexander samuel ball tyler baumann mack braden jared brown ryan callahan zach carnegie blake clanton clay cottingham michael davis london evans michael ford jordan gill danielle glass taylor keefer sam krusee eric lynn andrew mcmahan shann moore jacob owens kristin perry chelsea pierce nick purvis sanjay rajput adam rhoades chance stokes trey symington salena tew john thomas michael varhalla
culinary arts school memphis
mississippi state university school of architecture
professors a. gregory + h. herrmann
arc 3546 - arch. design III-b - spring 2012
Faculty Advisor Alexis Gregory Hans Herrmann Design / Editing Tyler Baumann Mack Braden Danielle Glass Taylor Keefer Michael Varhalla Typeset in Aller, Colaborate Printed by Lulu Enterprises, Inc. ©2012 School of Architecture College of Architecture, Art, & Design Mississippi State University All rights reserved All photographs and drawings are courtesy of the contributors and students unless otherwise noted. All efforts have been made to obtain lawful permission to reprint copyright images. No part of this book may be used or reproduced in any manner without written permission from the publisher, except for copying permitted by sections 107 and 108 of the U.S. Copyright Law and except for reviewers for the public press. Every effort has been made to see that no inaccurate or misleading data, opinions or statements appear in this Portfolio. The data and analysis appearing in the content herein are the responsibility of the contributors concerned.
ASSOCIATION OF COLLEGIATE SCHOOLS OF ARCHITECTURE
INTRODUCTION STUDIO SYNOPSIS
AWARD SUBMISSIONS
This collection of work acts as a summary of studies for the third year studio at the School of Architecture of Mississippi State University. The aspirations of the course serve to supply the studio with the most developed exercise in design process in their collegiate careers so far, ranging from site analysis and conceptual inspiration to design development. The said exercise is manifested in the students’ submission of work to Brick Industry Association, Association of Collegiate Schools of Architecture and Linel awards, for innovative uses in brick, steel, and facades respectively. The parameters for use of the theme materials are left to any given individual’s interpretation, as long as the program requirements are satisfied, as listed on the following spread. The results of the exercise and associated award winners are documented in the ensuing publication, which includes collaborative studio work, and accompanying individual portfolios of work for the project, to be viewed as companion text.
The ACSA (Association of Collegiate Schools of Architecture) has held an annual national competition encompassing innovative use of steel in architectural design for eleven consecutive years, with 2012 being no exception. In the twelfth iteration, the third year studio in the School of Architecture at Mississippi State University submitted their work as individual entries. The competition allows the student large freedom in choice of site and design aspects, with the only requirements being the use of steel and programmatic outline, which provided a basis on which the studio project was constructed. This, along with the competition sponsored by The Brick Industry Association challenges the students to expanding the dimensions of their theory in heightening their attention to microscopic design through material and details. In addition to the ACSA competition, the Linel Corporation has sponsored a competition encouraging the design of innovative facade systems. The individuals are permitted to use any material as an
emphasis in the design, as long as the facade system used on the project assesses the design issue of the exterior in an innovative manner. As well, The Brick Industry Association offers an award to students who submit winning designs to the organization who show a developed and innovative use of brick as a priamry building material. The Association has offered Mississippi State University’s School of Architecture an exclusive opportunity, allowing the third year studio’s members to be the only submittals. Accordingly, the winners of the competition shall be from Mississippi State’s studio.
PROGRAM Teaching Kitchens, 6 @ 1250 sf each
Professionally equipped teaching kitchens with top-quality, energy efficient commercial cooking equipment including ranges, ovens, refrigerators, freezers and mixers.
Pastry Kitchen 1250 sf
Professional pastry kitchen with steam-injected triple-deck ovens and a professional-quality dough sheeter.
Classrooms, 2 @ 450 sf each
Kitchen arranged for faculty-conducted demonstrations for groups of students.
Lecture Hall 1500 sf
For lectures, exhibits, and audio-visual presentations. The lecture hall is an ideal space to highlight the use of long-span steel structure.
Library 1800 sf
Reference library with computer terminals available to all students seven days a week.
Wine Room 650 sf
Must have full ventilation (so cooking odors from the pastry kitchens don’t intrude), bright incandescent light and white tabletops (for accurate wine viewing), and ample bottle storage space (including temperature-controlled Sub-Zero refrigeration and built-in cabinetry).
Bake Shop 600 sf
Must be accessible when school areas are closed and includes: seating area (250sf), service counter (75sf), kitchen area (175sf), food storage (50sf), and garbage / delivery area (50sf).
INTRODUCTION Restaurant 3000 sf
Public Restrooms, As Required by Code
Student-run restaurant with its own kitchen (approximately one-third the areas of the restaurant) and a seating capacity for 80 people. The dining area of the restaurant is an ideal space to highlight the use of long-span steel structure. Must be handicapped accessible
Receiving Area 900 sf
Main storage area including walk-in refrigerator and freezer as well as dry storage space. Ingredients are distributed from this area to the individual kitchens.
Administrative Offices
Director’s Suite 400 sf Including an office for the director and workspace for assistants, this suite supports the administrative business of the Institute Admissions Office 350 sf Career Services 300 sf Staff Room 250 sf Faculty Area 400 sf
Student Lounge 450 sf Trash Area 300 sf Outdoor Space(s) TBD by Participant Total Program Area
21,250 net square feet
Total Building Area
27,625 gross square feet
1 10
BUILDING CODE + ZONING
15
Occupancy Group: A-2 A-3 B S-2
20
Food and Beverage Research
12 13
14
part p art
ADA + EGRESS REQUIREMENTS
26 28
Accessibility Research
38 xx
Egress Research
xx xx xx
2 part
3
part p art
TABLE OF CONTENTS
68
SITE INVENTORY+ ANALYSIS
70
Analyses: climate studies demographics studies vernacular studies housing studies cultural studies civic studies circulation studies
90
On-Site Data Verification
PRECEDENT STUDY + PROGRAM
94
Precedents: cultural influences teaching organic farming restaurant precedents culinary school precedents
96
Programmatic spects: clients + users occupancy load spatial requirements
112
4 part p art
This section of the book addresses the building code and zoning requirements necessary to the project. The following codes and ordinances are either set down by the International Building Code (2006), the State of Tennessee, the city of Memphis, or the competition sponsors. Building codes and zoning ordinances include information on occupancy types, building types, fire rating for structures and materials, as well as the setbacks and other requirements for the project.
1
building code + zoning ADA + egress requirements site research + analysis precedent studies + program
culinary arts school | memphis, tn
mississippi state university | school of architecture
2x
8000 ft²
2x
2x 2x
7500 ft² a
x36 b 6000 ft²
4000 ft² 3000 ft²
x138 900 ft²
x6
x18
OCCUPANCY GROUP
b atio n La
yK itch en
ant taur Res
ons tr Dem
A-2
Pas tr
ASSEMBLY
Tea chin g
Kitc hen
0 ft²
600 ft²
x32
e Sh op
1250 ft²
Bak
2000 ft²
OCCUPANCY GROUP
2000 ft²
1
ASSEMBLY
2x
1800 ft²
: Unisex Restroom
x22
: Male Only Restroom
1500 ft²
1500 ft²
: Female Only Restroom
x100
: Lavatory (sink)
: Drinking Fountain : Occupant Load
1000 ft²
: Space is Sprinklered : Space is Fire-Rated
450 ft²
500 ft²
x30
ge St
ud
en t
Lo
un
Ha ll Le ctu re
Lib
rar y
0 ft²
BUILDING CODE + ZONING
13 | memphis, tn | arc 3546 | spring 2012
2x
A-3
culinary arts school | memphis, tn
mississippi state university | school of architecture
3x
2x
1000 ft² 900 ft²a
x44 b
800 ft² 600 ft² 400 ft²
400 ft²
400 ft²
x4
x26
350 ft²
300 ft²
x3
x2
200 ft²
250 ft²
x16
OCCUPANCY GROUP
oom ff R Sta
s vice Ser eer Car
Are ulty Fac
uite ’s S ctor
issio ns O ffice Adm
B
Dire
BUSINESS
Clas
sroo
ms
a
0 ft²
OCCUPANCY GROUP
1
STORAGE
1000 ft²
: Unisex Restroom
900 ft²
x3
: Male Only Restroom
: Female Only Restroom
650 ft²
x2
600 ft²
: Lavatory (sink)
: Drinking Fountain : Occupant Load
: Space is Sprinklered
400 ft²
: Space is Fire-Rated
200 ft²
oom Win eR
Rec
eivi
ng A rea
0 ft²
BUILDING CODE + ZONING
15 | memphis, tn | arc 3546 | spring 2012
800 ft²
S-2
culinary arts school | memphis, tn
mississippi state university | school of architecture
separation Type
Building Limits
Distance
I
II
III
10< x <30
Type - I
x >30
Type - II
Type - III
A
B
A
B
A
B
Height
UL
160’
65’
55’
65’
55’
Stories
UL
11
5
3
5
3
UL
UL
37,500 Sf
23,000 Sf
28,500 Sf
19,000 Sf
= 1 hr
= 0 hr
Primary Structure Frame (see section 202)
a
a
a
a
Building Elements
Exterior Bearing Wall Interior Bearing Wall Nonbearing walls and partitions Exterior
E
Nonbearing walls and partitions Interior Floor construction and secondary members (see section 202) Roof construction and secondary members (see section 202)
FIRE RATINGS AND BUILDING MEASUREMENTS
b
bc
bc
bc
STREETSCAPE STANDARDS
1
STREETSCAPE PLATES
1. A 5 foot wide sidewalk located at least 5 feet from the edge of the roadside drainage ditch.
2. A pedestrian bridge over the roadside drainage ditch will be required in the vicinity of a bus stop, intersection, and other pedestrian features. At least one pedestrian bridge over the roadside drainage ditch shall be provided per lot. 3. The proposed location of sidewalks and any interconnection between the sidewalk and the street are subject to approval by the City or County Engineer, depending on the road location.
4. The amount of flow and size of the roadside ditch will be considered and may result in some requirement for drainage improvements.
BUILDING CODE + ZONING
17 | memphis, tn | arc 3546 | spring 2012
If non-existing, curbs and gutters may be approved by the Planning Director waiving the streetscape standards, and if there are no planned public projects to build such in the next 10 years. The minimum standards shall be followed:
culinary arts school | memphis, tn
mississippi state university | school of architecture
UPPER FLOOR HEIGHT
UPPER FLOOR TRANSPARENCY UPPER FLOOR TRANSPARENCY
UPPER FLOOR HEIGHT GROUND FLOOR TRANSPARENCY GROUND FLOOR HEIGHT
BUILDING TRANSPARENCY
BUILDING PLACEMENT
1
SETBACK AREA
SETBACK PLAN/SECTION
2 ft. min. (7 ft. if ground floor use is a restaurant with outdoor seating) to 15 ft. max. behind right of way line.
8’-0” Clearance Clear Pedestrian Route Storefront Furniture, Planters, Landscape
7’-0”
RIght of Way Setback Area
5’-0” 17’-0”
5’-0”
Street Furniture, lighting and trees Right-of-Way
For any infill project in the central business district with less than 75 feet of frontage, and upon approval of the Planning Director, structures may be located closer to the right-of-way line than the minimum setback permits provided that the structure is located within the range of front setbacks on the street. This range of setbacks is measured on the basis of the four structures surrounding the project site (the two closest lots in either direction along the street). The new structure shall be located within the range of established setbacks (no closer than the narrowest setback, no further than the deepest setback). Where a setback in these four lots is significantly out of the range of setbacks along the street, it may be eliminated from the range. SIDE/REAR SETBACKS
Abutting single-family: 10 ft. min. Abutting multifamily, nonresidential: 0 or 10 ft. min. Abutting alley: 5 ft. min. Building separation: 10 ft. min.
BUILDING CODE + ZONING
19 | memphis, tn | arc 3546 | spring 2012
CONTEXTUAL INFILL
culinary arts school | memphis, tn
mississippi state university | school of architecture
CONSTRUCTION + MAINTENANCE FLOOR CONSTRUCTION: Floor coverings for all food preparation, FLOOR CONSTRUCTION food storage, and utensil-washing areas, Appropriate Flooring as well as floors of walk-in refrigeration units, dressing rooms, locker rooms, toilet rooms and vestibules should be made of a smooth durable material that CONCRETE is sealed. FLOORING WALLS + CEILINGS: Shall be nonabsorbent, light colored, smooth, and easily cleanable. VENTILATION: All rooms shall have sufficient ventilation to keep them free of excessive heat, TERRAZZO steam, condensation, vapors, obnoxious FLOORING odors, smoke and fumes. Ventilation systems shall be installed and operated according to law and, when vented to the outside, shall not create an unsightly, harmful, or unlawful discharge. FLOOR DRAINS: CERAMIC TILE Shall be provided in floors that are water-flushed for cleaning or that receive discharges of water or other fluid waste from equipment, or in areas where presLINOLEUM sure spray methods for cleaning equipFLOORING ment are used. Such floors shall be constructed only of sealed concrete, terrazzo, ceramic tile, or similar materials PLASTIC and shall be graded to drain.
FLOORING
FDA REGULATIONS
EXPOSED CONSTRUCTION PREVENTED
LIGHTING
Areas these elements not allowed include: food prep. areas, equipment washing, utensil washing areas, toilet rooms, and vestibules
Amount of light listed must be provided at a distance of thirty ( 30) i nches from t he floor a nd higher
Amount of Light Area Type (foot candles)
EXPOSED STUDS
EXPOSED JOISTS
EXPOSED RAFTERS
food prep. surface
light 20
equipment work level
light 20
utensil work level
light 20
any prep location
light 20
walk in refrigerator
light 10
storage areas
light 10
all other areas
light 10
dining areas during cleaning
light 10
UTILITY LINE INSTALLATION: Shall be installed in a way that does not obstruct or prevent cleaning of floor. ATTACHMENTS: Light fixtures, vent covers, wall-mounted fans, and similar equipment a ttached to walls and ceilings shall be easily cleanable and shall be maintained in good repair.
FDA REGULATIONS
HAZARDOUS FOOD TEMPERATURES food temp.
140 F
food temp.
0F
frozen food temp.
EQUIPMENT + UTENSIL STORAGE
CONTAINERS MUST RESIST
-temperatures must be maintained except during preparation periods. -numerically scaled indicating thermometer is required for each mechanically refrigerated facility. thermometer accuracy = +- 3 F
UTENSIL CONTAINERS
6 INCHES
FOOD STORAGE
GROUND
CONTAINERS MUST RESIST
PALLETS
FOOD CONTAINERS RACKS
6 INCHES
GROUND
-metal pressurized beverage containers and cased food packaged in cans, glass or other water proof containers don’t need to be elevated.
At all times including while being stored,
prepared, displayed, served, or FOOD PROTECTION: transported food shall be protected from At all times potential including while being contamination including dust, stored, prepared, displayed, served, or and insects, rodents, unclean equipment unnecessary handling, transported foodutensils, shall be protected from coughs and sneezes, flooding, drainage, and potential contamination including dust,drippage overhead leakage or overhead condensation. insects, rodents,from unclean equipment and WARE STORAGE: utensils, unnecessary handling, coughs Cleaned and sanitized equipment and and sneezes, flooding, utensils shall drainage, be handled inand a way that protects them from contamination. overhead leakage or overhead dripping Spoons, knives, and forks shall be touched from condensation. only by their handles.
WARE STORAGE: Cleaned and sanitized equipment and DOLLIES utensils shall be handled in a way that protects them from contamination. Spoons, knives, and forks shall be -containers may be stored on these items provided that they are easily movable. tyler baumann -containers of food may not be stored under exposed sewer lines or non-potable touched only by their handles. water lines, except for automatic fire sprinkler heads.
sources | http://health.state.tn.us/geh/food_service.htm
ACCEPTABLE STORAGE CONTAINERS
FOOD CONDITIONS: + STORAGE Food shall beFOOD in PROTECTION sound condition, free from spoilage, filth, or other FOOD CONDITIONS: be in sound condition, contamination Food and shall shall be safe forfree from spoilage, filth, or other contamination and human consumption. Food shall be shall be safe for human consumption. shall be obtained from sources that obtained from Food sources that comply comply with laws and relating to food and with all laws relating to all food food food labeling. The use of food in labeling. The use of food insealed hermetically hermetically containers, not prepared in a in food processing sealed containers, not prepared a food establishment, is prohibited. processing establishment, is prohibited. FOOD PROTECTION: 21 | memphis, tn | arc 3546 | spring 2012
mississippi state university | school of architecture
41 F
1
FOOD PROTECTION + STORAGE FDA REGULATIONS
culinary arts school | memphis, tn
honors assignment 1 | 03.21.12 professors gregory + herrmann arc 3546 | spring 2012
FDA REGULATIONS
BUILDING CODE + ZONING
culinary arts school | memphis, tn
mississippi state university | school of architecture
SANITATION + CLEANING
F
culinary arts school | memphis, tn
mississippi state university | school of architecture
CLEANING METHODS FOR FREQUENCY OF CLEANING SURFACES AND EQUIPMENT: -30 seconds in at least 170 F water Once a Day -60 seconds in solution containing After Each Use fifty parts per million chlorine as a hypochlorite at 75 F KITCHENWARE GRILL -immersion for 60 seconds in cleaning solution half parts per million iodine and having a pH no higher than 5.0 at 75 F CUTTING GRIDDLES -rinsing, spraying, or swabbing with BLOCKS chemical sanitizing solution of at least twice MICROWAVE HANDLING: TABLE OVENS Cleaned and sanitized equipment and utensils shall be handled in a way that WASHING protects them from contamination. MACHINES Spoons, knives, and forks shall be touched only by their handles. Cups, glasses, bowls, plates, and similar items WATER SUPPLY REGULATIONS shall be handled without contact with 15 PSI rinse water pressure 25 PSI inside surfaces or surfaces that contact POTABLE WATER: must have a bacteriological test annually to determine quality of water. the user’s mouth. TRANSPORTATION: if water not brought in by a pipe, bulk water transport MATERIALS: Multi-use equipment and utensils shall be must be provided. corrosion resistant and nonabsorbent; BOTTLED WATER: must be obtained from a source that complies with all laws and they shall be smooth, easily that protect against contamination. cleanable, and durable under conditions STEAM: steam used in contact with food shall be free from additives. of normal use. Equipment, utensils, and single service articles shall not impart sources | http://health.state.tn.us/geh/food_service.htm odors, color, or taste, nor contribute to the contamination of food.
FDA REGULATIONS
SANITATI
MACHINE WASH REQUIREMENTS SINGLE TANK, STATIONARY RACK, DUAL TEMPERATURE MACHINE wash temperature 150 F final rinse temperature 180 F
SINGLE TANK, STATIONARY RACK, SINGLE TEMPERATURE MACHINE wash temperature 165 F final rinse temperature 165 F
SINGLE-TANK, CONVEYOR MACHINE wash temperature final rinse temperature
160 F 180 F
150 F 160 F 180 F
SINGLE-TANK, POT, PAN, AND UTENSIL WASHER (EITHER STATIONARY OR MOVING RACKS) wash temperature 140 F final rinse temperature 180 F
-all equipment and utensils shall be air dried
-30 seconds -60 second parts per mi at 75 F -immersion solution hal having a pH -rinsing, sp chemical sa twice HANDLING:
Cleaned an utensils sha protects t Spoons, kniv only by th bowls, plate handled w surfaces or user's mout
MATERIALS:
MULTITANK, CONVEYOR MACHINE wash temperature pumped rinse temperature final rinse temperature
CLEANING M EQUIPMENT
Multi-use eq corrosion re they shall be durable und Equipment, articles sha taste, nor co of food.
ho pr
FDA REGULATIONS
1
WASTE + PREMISES
PREMISES:FDA REGULATIONS Food service establishment and all + PREMISES partsWASTE of property used in connection shall PREMISIS: be kept litter free. Also, traffic of Food service establishment and all parts unnecessary persons through food of property used in connection shall be preparation andAlso, utensil areas is kept litter free. traffic washing of unnecessary persons through food preparation and prohibited.
culinary arts school | memphis, tn
mississippi state university | school of architecture
PERIMETER MATERIALS
SURFACES:
Concrete
Gravel
Asphalt
EXTERIOR WASTE CONTAINERS
Walking and driving surfaces of all exterior SURFACES: areas are to be surfaced with concrete or Walking surfaces asphalt,and or withdriving gravel or similar materialof all to facilitate minimize with exterior areasmaintenance are to beandsurfaced dust. concrete or asphalt, or with gravel or DISPOSAL: Garbage and refuse shall be disposed of at similar material to facilitate maintenance such frequency to prevent the and minimize dust. development of odor and the attraction of insects and rodents.
LAUNDRY FACILITIES:
easily cleaned
tight-fitting lids, doors, or covers
shall be kept covered
-a sufficient number of containers is required to hold all garbage and refuse that accumulates. -soiled containers shall be cleaned at a frequency to prevent insect and rodent attraction.
BATHROOM FACILITIES Toilet facilities shall be installed according to law, shall be the number required by law, shall be conveniently located, and shall be accessible to employees at all times. Establishments with a seating capacity of sixteen (16) seats or less shall be exempted from providing toilet facilities for the use of patrons.
sources | http://health.state.tn.us/geh/food_service.htm
Toilet rooms opening directly into food preparation, utensil washing, dining or storage areas shall be completely enclosed and shall have tight-fitting, selfclosing, solid doors, which shall be closed except during cleaning or maintenance, except as provided by law.
DISPOSAL: Laundry facilities in a food service establishment shall be shall restricted the Garbage and refuse beto disposed of atwashing such frequency to prevent the and drying of linens, cloths, uniforms, and development of odor and the attraction aprons necessary to the operation. If such items are laundered on the premises, an of insects and rodents. electric or gas dryer shall be provided and used. Rooms shall be provided for laundry facilities except that such operations may LAUNDRY FACILITIES: be conducted in storage rooms containing Laundry facilities a foodsingleservice only packaged foods in or packaged service articles. establishment shall be restricted to the
washing and drying of linens, cloths, uniforms, and aprons necessary to the operation. If such items are laundered tyler baumann on the premises, an electric or gas dryer honors assignment 1 | 03.21.12 professors gregory herrmannRooms shall be provided and +used. arc 3546 | spring 2012 shall be provided for laundry facilities FDA REGULATIONS except that such operations may be conducted in storage rooms containing only packaged foods or packaged single service articles.
BUILDING CODE + ZONING
23 | memphis, tn | arc 3546 | spring 2012
utensil washing areas is prohibited.
SECTION SOURCES International Building Code. Falls Church, VA: International Code Council, 2006
The following section of this book discusses the requirements set down by the International Code Council (IBC 2006) that involves methods of egress as well as requirements established by the Americans with Disabilities Act (2004). These regulations are vitally important to this project as they help to make buildings safe by establishing minimum requirements as well as allowing for the building to be functional for all people. Items set forth in this section include the maximum distance egress paths can be from another, how large these methods of egress must be, and the amount of space needed under a counter in order for an occupant in wheelchair to use that counter.
2
building code + zoning ADA + egress requirements site research + analysis precedent studies + program
culinary arts school | memphis, tn
mississippi state university | school of architecture
EXIT PASSAGEWAYS (IBC SECTION 1023) 1: Similar to corridors in exit access but have more restrictions placed on their use – no purpose other than as means of egress – used for horizontal portions of exits Can have no other openings 44” minimum width for typical exit passageways Doors cannot project more than 7” when open or reduce width off passageway by half EXIT DESIGN Exits must be continuous from point of entry from exit access to exit discharge
1
Travel distance in exits is not limited
EXIT PASSAGEWAY LOCATION
EGRESS
2 EXIT DISCHARGE (IBC SECTION 1027) At grade or provide direct access to grade
2: Exit discharge components must be separated from adjoining property lines by 10’ minimum and from other buildings on the same lot
EXIT DISCHARGE SETBACKS
EXIT STAIRS (IBC SECTION 1026)
Must be open on one side with aggregate open area of 35 sq ft minimum at each floor level and landing Opening minimum of 42” above walking surface and must face yards, courts, or public ways
EXIT DISCHARGE LOCATION
ADA + EGRESS REQUIREMENTS
29 | memphis, tn | arc 3546 | spring 2012
Cannot re-enter the building
2
culinary arts school | memphis, tn
mississippi state university | school of architecture
EXIT ENCLOSURES (IBC SECTION 1022) All interior exit stairways must be enclosed (IBC SECTION 1022.1) 1: Exit enclosure terminates at an exit discharge or public way Exit passageway must be separated from the enclosure by a fire barrier or horizontal assembly (IBC SECTION 1022.2) 2: Elevators cannot open into an exit passageway (IBC SECTION 1022.3)
2 1 EXIT TERMINOLOGY
3: Egress stairs at perimeter can be unprotected – stairwell walls flush with the enclosure do not need to be rated if the angle between the walls is greater than 180 degrees
3
4: If angle is less than 180 degrees, the exterior wall must be rated 1 hour with ¾ hour opening protectives within 10’ of the enclosure (IBC SECTION 1022.6)
4
Stairs in the exit enclosure can’t extend below the level of discharge unless an approved barrier is provided to keep occupants from going down below the level of discharge (IBC SECTION 1022.7) STAIRWELL WALL FIRE RATINGS
EGRESS 5
2 EXIT ACCESS
5: When 2 exits are needed, they must be placed half distance of the diagonal dimension of space – measure to center line of doorway
6
6: Measurements can go outside the building With 1 hour fire-rated corridor, exit separation is measured along the direct exit path
THREE-EXIT LOCATIONS
7: With 3 exits, 2 exits must comply with separation requirements and third can be a reasonable distance if one should get blocked
7
Exit access travel distance measured from most remote point in space to entrance of an exit along the natural and unobscured path (IBC SECTION 1016.1) Usually allowable travel distance is 200’ without sprinklers and 250’-300’ with sprinklers
EXIT LOCATIONS
ADA + EGRESS REQUIREMENTS
31 | memphis, tn | arc 3546 | spring 2012
All exits must be obvious and arranged for easy use (IBC SECTION 1015.2)
culinary arts school | memphis, tn
mississippi state university | school of architecture
MAINTAINING EGRESS WIDTH (IBC SECTION 1003) 1
Any objects obstructing or projecting in the means of egress shall not decrease the required width of the means of egress 1: Where obstructions or projections occur, additional width is needed to maintain the required egress width
required egress width
2 EGRESS WIDTH (IBC SECTION 1005) 2: Door should project a maxiumum of 7” into required width
3
3: Opening of door should not reduce required width by more than one-half
4
4: Doors must be recessed along narrow corridors 5: Door allowed 7” maximum projection due to recession
5 required egress width
6: Nonstructural provision can project into corridor maximum of 1-1/2”
6 DOOR AND CORRIDOR DIMENSIONS
EGRESS
2 FLOOR TO FLOOR EGRESS
7: Egress paths from floor to floor must not decrease. Assuming A, B, C, and D are approximately of equal size and occupant load, egress path does not have to increase as long as the exit capacity does not decrease in the direction of egress travel. The occupants of the floor below are assumed to exit that level before those behind them get to same point in the egress system (IBC SECTION 1004.4) MEZZANINE EGRESS
8
EGRESS DIAGRAMS
8: Occupants from a mezzanine must pass through the floor below to get to a common set of exit paths and thus are added to the occupant load (IBC SECTION 1004.6)
ADA + EGRESS REQUIREMENTS
33 | memphis, tn | arc 3546 | spring 2012
7
culinary arts school | memphis, tn
mississippi state university | school of architecture
MULTIPLE OCCUPANCIES 1: When different occupancies share common egress paths, the most stringent requirements for each occupancy will govern the means of egress system (IBC SECTION 1004.9)
2
2: Assuming Group B occupancy contains an occupant load greater than 50, at least two means of egress are required (IBC SECTION 1004.9) Note: Outdoor areas, such as dining patios behind restaurants, are to be included in occupant-load calculations and provided with exits. When it can be anticipated that the occupants of an outdoor area would be in addition to those occupants inside the building, this occupant load must be added to the egress-capacity calculations (IBC SECTION 1004.8)
1
3
MERGING EGRESS PATHS 3: When egress paths merge, the capacity of the egress paths serves both tributary areas, and the paths shall not decrease in the direction of egress travel (IBC SECTION 1004.4)
EGRESS PATH DIAGRAMS
EGRESS 4
2 AISLES (IBC SECTION 1017)
5
Any occupied portions of an exit access must be unobstructed
5: Minimum dimension doesn’t apply to tables of 4 or less where aisle access is less than 6’ away
6
6: Length of travel in an aisle accessway is limited to 30’ before a choice of two or more paths of egress 7: Chairs must be given 19” of space which must be allotted in the aisle space 8: Fixed seats can be measured from the back (IBC SECTION 1017.4)
7
8 9 AISLE MEASUREMENTS
9: aisles
Aisle accessways lead to
ADA + EGRESS REQUIREMENTS
35 | memphis, tn | arc 3546 | spring 2012
4: Minimum of 12” wide and increase by ½” per foot of aisle access travel beyond 12” from the aisle
culinary arts school | memphis, tn
mississippi state university | school of architecture
1
AISLES (IBC SECTION 1017) 2
1: Doors cannot reduce the aisle width by greater than half 2: May not reduce aisle width by greater than 7” when open Rails and trims cannot protrude more than 1-½” 3: Aisles Groups M and B must be a minimum of 36” (IBC SECTION 1017.2)
3
Aisles in nonpublic areas with less than 50 occupants and not accessible can be 28” wide (IBC SECTION 1017.2)
AISLE ACCESS MEASUREMENTS
EGRESS
2 CORRIDORS (IBC SECTION 1018)
Enclosed exit access component that provides a path of egress to an exit
4: 20’ limit for a dead end corridor – exception of 50’ with sprinklers – don’t apply with only one exit
4
5
5: Not limited in length when 2-½ times the least width of the dead end (IBC SECTION 1018.4) Corridors cannot be part of an airsupply or return system (IBC SECTION 1018.5)
DEAD END CORRIDOR DIMENSIONS
Can be used for make-up air exhaust for toilet rooms, dressing rooms, janitor’s closet
Corridors cannot be interrupted by intervening rooms (except foyers, lobbies, or reception rooms with same fire rating) (IBC 1 SECTION 1018.6) Elevator lobbies off corridors not considered dead-end when width exceeds 2-½ times their depth
CORRIDOR LENGTHS BASED ON OCCUPANCY
ADA + EGRESS REQUIREMENTS
37 | memphis, tn | arc 3546 | spring 2012
Usually 1 hour fire resistance rating
culinary arts school | memphis, tn
mississippi state university | school of architecture
ACCESSIBLE MEANS OF EGRESS (IBC SECTION 1007) Exterior areas for assisted rescue have the same space requirements for wheel chairs as for area of refuge (IBC SECTION 1007.7) 1
1: Exterior areas must be open to outside air and be separated by walls of 1-hour construction with ¾-hour doors 2: The protection must extend beyond the area laterally and vertically for 10’ (IBC SECTION 1007.8) 3: Two-way communication systems are to be provided either at the elevator level (IBC SECTION 1007.8) or at the area of refuge (IBC SECTION 1007.6.3). Must be visual and audible
3
ACCESSIBLE EGRESS DIAGRAM
2
EGRESS
2 ACCESSIBLE MEANS OF EGRESS (IBC SECTION 1007)
One accessible means of egress is to be provided by elevator with standby power and signal devices for buildings with four or more stories 4: Stairways must be at least 48” wide between handrails. (Not required for exit stairways) (IBC SECTION 1007.3)
5
5: Area of refuge must be in a stairway or have direct access to an enclosed stairway or to an elevator with emergency power (IBC SECTION 1007.6) Area of refuge must not reduce egress width
4
6: The area of refuge must provide 30” x 48” wheelchair space for each 200 occupants of the space served
7
AREA OF REFUGE & ILLUMINATION DIAGRAM
ILLUMINATION (IBC SECTION 1006.2)
7: Illumination level for means of egress be not less than 1 foot-candle at the walking surface level
ADA + EGRESS REQUIREMENTS
39 | memphis, tn | arc 3546 | spring 2012
6
culinary arts school | memphis, tn
3
mississippi state university | school of architecture
TREADS AND LANDINGS (IBC SECTION 1009.3) 2
1: Treads shall have a minimum depth of 11” 2: Stairways must have landings at the top and bottom, and at changes in direction
LANDING DIMENSIONS
3: Landings are to have a width no less than that of the stairway they serve, and a minimum length equal to the width of the stairway
1 4
Landings serving a straight-run stairway, even if the stair width exceeds 48”, need not be greater than 48” A single flight of stairs may not exceed 12’ in vertical rise between floors or landings (intermediate landings are required when rise exceeds 12’)
STAIR DIMENSIONS 5
RISER SPECIFICATIONS (IBC SECTION 1009.3.3) 4: Risers shall have a minimum height of 4” and a maximum height of 7” 5: Non-accessible paths may be open (opening may not allow a 4” sphere in diameter to pass through)
RISER OPENING DIMENSION
EGRESS
2 STAIRWAYS (IBC SECTION 1009)
5: Must have at least 80” of headroom at any point
STAIR WIDTH DIMENSION
5
RISER SPECIFICATIONS (IBC SECTION 1009.3.3)
Must be closed on accessible egress paths Nosings and projections 8: 1/2” bevel maximum 9: 1/2” radius maximum 10: 1-1/4” projection maximum 11: 30 degree maximum
HEADROOM ON STAIRS
11
8 9
STAIR NOSING DIMENSIONS
10
ADA + EGRESS REQUIREMENTS
41 | memphis, tn | arc 3546 | spring 2012
4: Stairway width must be at least 44”, unless occupant load is less than 50. This allows for a minimum width of 36” (IBC SECTION 1009.1)
4
culinary arts school | memphis, tn
mississippi state university | school of architecture
ENCLOSURES UNDER STAIRS (IBC SECTION 1009.6.3) Enclosed usable space under stairs should be protected with 1-hour fireresistance-rated construction These requirements apply only when the usable space under the stairway itself is enclosed ROOF ACCESS Buildings four or more stories in height must have at least one stairway that extends to the roof unless the roof is sloped at more than a 4-in-12 pitch (IBC SECTION 1009.13)
STAIR ENCLOSURES
1 CIRCULAR STAIRS (IBC SECTION 1009.4) 2
CURVED AND WINDING STAIRS 1: The smaller radius of the stairway must be no less than twice the width of the stair way 2: The treads shall be no less than 10” at the narrow end, and not less than 11“ when measured at a point 12” from the narrower end of the tread CIRCULAR STAIR DIMENSIONS
EGRESS
2 CIRCULAR STAIRS (IBC SECTION 1009.4)
4
SPIRAL STAIRS
Spiral stairs may be used in spaces of 250 sf in area or less, and serving a maximum of 5 occupants
3: Treads shall be no less than 7-½” at a point 12” from the narrow end 4: 26”
Minimum width of stairway is
5: Risers of a spiral stair shall have a height sufficient to provide a minimum headroom of 78”
5
6
SPIRAL STAIR DIMENSIONS
6: Also, risers may not be more than 9-½” in height
ADA + EGRESS REQUIREMENTS
43 | memphis, tn | arc 3546 | spring 2012
3
culinary arts school | memphis, tn
mississippi state university | school of architecture
EGRESS DOORS (IBC SECTION 1008) 1
To provide minimum opening clearance, doors should always be 3’-0” x 6’-8” Egress doors should be side hinged
2
For occupant loads of more than 50 or of high-hazard, swing in direction of exit travel (IBC SECTION 1008.1.2) 1:
Height is no less than 80”
2: Minimum clear width of 32” measured from the face of the door to the stop when door is open 90 degrees
EGRESS DOOR DIMENSIONS
EGRESS
2 LANDINGS (IBC SECTION 1008)
4
5
There should be a landing or floor on each side of a door with the same elevations (IBC SECTION 1008.1.5) 3: Width no less than that of the stairway or the door, whichever is largest (IBC SECTION 1008.1.6)
4: Open doors should not reduce required width of landing by more than 7” 5: Minimum length of 44” in direction of travel
6
7
LANDING DIMENSIONS
6: For occupant groups of 50 or more, the door in any position must not reduce the required width to less than half 7: Doors in series must be 48” apart, plus the swing of the door (IBC SECTION 1008.1.7)
ADA + EGRESS REQUIREMENTS
45 | memphis, tn | arc 3546 | spring 2012
3
culinary arts school | memphis, tn
mississippi state university | school of architecture
CEILING HEIGHT (IBC SECTION 1003.2) 1: 7’-6” minimum ceiling height requirement 2: Egress areas above and below mezzanine floors are to have clear heights of at least 7’ (IBC SECTION 505.1)
1 2
4
3: Maximum of 50% of the ceiling area of egress may be reduced to an 80” height by protruding objects DOOR HEIGHT
PROTRUDING OBJECTS (IBC SECTION 1003.3) 4: Door closers and stops may not reduce headroom to less than 78”
3
5: Barriers to protect visually impaired persons must be provided where vertical clearance is less than 80”
5
6
6: Barriers cannot exceed 27” above the floor 7: Also due to protecting the visually impaired, structural elements, fixtures and furnishings may not project horizontally more than 4” between heights of 27” to 80”
7
CEILING HEIGHT DIMENSIONS
PROTRUDING OBJECT DIMENSIONS
EGRESS
2 LOCKS AND LATCHES (IBC SECTION 1008.1.9)
8
Egress doors should be readily operable from egress side without the use of a key or special knowledge or effort
9
8: Doors must be accessible without pinching or grasping the hardware. Lever handles meet these criteria (IBC SECTION 1001.8.1) 9: Door handles, pulls, locks, and other operating hardware are to be installed 34” to 48” above the finished floor
DOOR HARDWARE SPECIFICATIONS
ADA + EGRESS REQUIREMENTS
47 | memphis, tn | arc 3546 | spring 2012
Requires no more than one operation.
culinary arts school | memphis, tn
mississippi state university | school of architecture
PANIC HARDWARE (IBC SECTION 1008.1.10) Required in Group A or E occupancies having occupant load of 50 or more and in Group H occupancies with any occupant load
1
1: Designed to open the door if person is pressed against it. It is always used in conjunction with doors opening in the direction of egress 2: Discharge door at the end of the path of egress may be locked on the exterior side 3: Discharge door must openable from the egress side.
be
2
3
DISCHARGE DOOR SPECIFICATIONS
PANIC HARDWARE SPECIFICATIONS
EGRESS
2 ACCESSIBLE RAMPS (ADA SECTION 405) 4: Rise 30” maximum (ADA SECTION 405.6)
5
Minimum head room 80”
6: Running slope no steeper than 1:12 (ADA SECTION 405.2) 36” clear width minimum between handrails (ADA SECTION 405.5)
60” minimum length of ramp landings, 60”x60” minimum for change in direction of landings (ADA SECTION 405.7)
4 RAMP DIMENSIONS
6
Ramps with a rise greater than 6” need handrails (ADA SECTION 405.8) Width of ramp in egress no less than width of corridor - 36”-44” typical
Ramps need handrails on both sides if rise is greater than 6”
ADA + EGRESS REQUIREMENTS
49 | memphis, tn | arc 3546 | spring 2012
5:
culinary arts school | memphis, tn
mississippi state university | school of architecture
RAMP LANDINGS
1
1: Landings at top and bottom of ramps - also needed with a change in direction 2: Landing width must be the same as that of any adjoining ramps
2
3: 60” landings
3
minimum
length of
4: Landings with a change in direction must be a minimum of 60” x 60” Landings can have 1:48 slope for drainage
4
5: Doors opening onto landings cannot reduce clear width to less than 42”
5
EGRESS
RAMP LANDING DIMENSIONS
ACCESSIBLE PATHS
2 ROUTES
Accessible routes are to be provided at site arrival points: street, parking, public transportation stops, etc
An accessible route is continuous and unobstructed. Any accessible path for a person with disabilities must not cut them off from the spaces they have a right to use
6
ACCESSIBLE ROUTES
The “path of travel” must extend to the edge of the project site
ADA + EGRESS REQUIREMENTS
51 | memphis, tn | arc 3546 | spring 2012
6: An accessible path of travel is to be provided from accessible entrances to each portion of the building. If only one route is provided it may not pass through a kitchen or service space
culinary arts school | memphis, tn
mississippi state university | school of architecture
ENTRY WAYS 1: When a service entrance is the only entry to a building it must be accessible
1
2: Entrances to tenant spaces need to be accessible because accessible entries are already provided into the building 3: This entry may not need to be accessible if 60% of the other entrances are accessible. If a building has a maximum of two entries then both must be accessible 3
AREAS TO CONSIDER Mezzanines and similar multilevel spaces must be connected to an accessible route unless they are under 3,000 sf in area, but in general all spaces should be accessible
2
Individual work stations are not required to be accessible but must be on an accessible route Raised areas with limited access such as elevator pits, crawl spaces, etc. are not required to be accessible
ACCESSIBLE PATHS
ACCESSIBLE ENTRANCES
53 | memphis, tn | arc 3546 | spring 2012
ELEVATORS
ADA + EGRESS REQUIREMENTS
2
culinary arts school | memphis, tn
mississippi state university | school of architecture
ACCESSIBLE DOORS (ADA SECTION 404) Revolving doors are not an accessible route (ADA SECTION 404.2.1) 32” minimum clear width (ADA 404.2.3) Door hardware 34” minimum and 48” maximum height above finish floor (ADA SECTION 404.2.7)
DOOR CLEARANCE DIMENSIONS
DOORS
CLEARANCES
2 CLEAR FLOOR AND GROUND SPACE (ADA SECTION 305)
30” min
One full unobstructed side of clear floor space must adjoin an accessible route or another clear floor space (ADA SECTION 305.6) Alcoves 36” wide minimum where depth exceeds 24” (ADA SECTION 305.7.1)
CLEAR FLOOR SPACE DIMENSIONS
X > 15”
X > 24”
Alcoves 60” wide where depth exceeds 15” (ADA SECTION 305.7.2)
60” min 36” min
FORWARD ALCOVE DIMENSIONS
SIDE ALCOVE DIMENSIONS
ADA + EGRESS REQUIREMENTS
55 | memphis, tn | arc 3546 | spring 2012
Clear floor space minimum of 30”x48” (ADA SECTION 305.3)
48” min
culinary arts school | memphis, tn
mississippi state university | school of architecture
30” min
9” min
27” minimum height of knee clearance – 30” minimum width – 8” minimum depth (ADA SECTION 306.3)
25” max 11” min elevation
plan
KNEE CLEARANCE DIMENSIONS
30” min
25” maximum depth of toe clearance under an element – 17” minimum depth under element – 9” above finish floor – 30” minimum width of element itself (ADA SECTION 306.2)
27” min
KNEE AND TOE CLEARANCE (ADA SECTION 306)
9”
6” max elevation
TOE CLEARANCE DIMENSIONS
17”-25” plan
CLEARANCES
2 TURNING SPACES (ADA SECTION 304)
24” max
T-shape space should have minimum 60” wide arms and 36” wide base – arms must be clear of obstructions 12” minimum in each direction (ADA SECTION 304.3.2)
32” min
36” min
48” min
Doors swing into turning spaces (ADA SECTION 304.4)
CLEAR WIDTH DIMENSIONS
WALKING SURFACES (ADA SECTION 403)
24” min
42” min 36” min 12” min
Clear width 36” minimum (ADA SECTION 403.5.1)
60” min
36” min
48” min
60” min
60” min
42” min
X < 48 12” min
T-TURN DIMENSIONS
180 degree turn
36” min
36” min
X < 48 180 degree turn (exception)
TURN AROUND DIMENSIONS
With 180 degree turn around an element less than 48” wide and clear width 42” minimum approaching turn, 48” minimum width at turn and 42” minimum width leaving turn (ADA SECTION 403.5.2) 60” x 60” minimum passing space (ADA SECTION 403.5.3)
ADA + EGRESS REQUIREMENTS
57 | memphis, tn | arc 3546 | spring 2012
24” max
60” diameter minimum circular turning space (ADA SECTION 304.3.1)
culinary arts school | memphis, tn
mississippi state university | school of architecture
REACH RANGES (ADA SECTION 308)
10” max
UNOBSTRUCTED SIDE REACH
CLEARANCES
44” max
48” max
15” min
With parallel approach, 34” maximum obstruction height and 24” depth – high side reach 48” maximum height for 10” depth and 46” high reach over 10” of depth (ADA SECTION 308.3.2)
OBSTRUCTED FORWARD REACH
48” max
48” high unobstructed side reach and 15” minimum – obstruction allowed between ground space and element with UNOBSTRUCTED FORWARD REACH 10” maximum depth (ADA SECTION 308.3.1)
48” max
15” min
Reach over forward obstruction 20”25” maximum depth – 48” high reach for 20” depth of obstruction and 44” high reach if obstruction over 20” deep (ADA SECTION 308.2.2)
> 20”-25” max
48” max
20” max
10” max
46” max
Forward reach 48” maximum height and 15” minimum height when unobstructed (ADA SECTION 308.2.1)
> 10”-24” max
OBSTRUCTED SIDE REACH
BATHROOMS
2 TOILET AND BATHING ROOMS (ADA SECTION 603)
Mirrors 40” maximum above the finish floor from the bottom edge of the reflecting surface (ADA SECTION 603.3)
WATER CLOSET DIMENSIONS
DISPENSER LOCATIONS
Shelves 40”-48” above floor (ADA SECTION 603.4)
WATER CLOSETS (ADA SECTION 604)
Grab bars must be on side wall and rear wall (ADA SECTION 604.5)
SIDE GRAB BAR
URINAL DIMENSIONS
Side bar 42” long minimum located 12” maximum from rear wall and extending 54” minimum from rear wall 36” long rear bar with 12” minimum extent from centerline of toilet on one side and 24” on the other side LAVATORIES (ADA SECTION 606)
REAR GRAB BAR
COMPARTMENT DIMENSIONS
34” maximum height above floor (ADA SECTION 606.3)
ADA + EGRESS REQUIREMENTS
59 | memphis, tn | arc 3546 | spring 2012
Doors cannot swing into the clear floor space or clearance for fixtures (ADA SECTION 603.2.3)
culinary arts school | memphis, tn
mississippi state university | school of architecture
KITCHEN CENTERS SINK CENTER 1: 24”-36” counter space on either side REFRIGERATOR CENTER 2: 15” minimum counter space on latch side of refrigerator RANGE CENTER 3: 18”-24” counter space on either side
4
14” minimum clearance between center of front eye and edge of counter
5
36”-42” between range and sink, refrigerator, or wall oven
6 3
COUNTERS 4: 18” minimum clearance between counter overhead cabinet 5:
36” typical counter height
6:
24” typical counter depth
7:
3” toe space
2
1
KITCHEN CENTER LOCATIONS
7
KITCHENS
2 ACCESSIBLE KITCHENS 8: 5’ minimum U-shaped kitchens
width
in
10: 4’ minimum width in parallel 10 wall kitchens 11: 5’ minimum width between counter and island in L-shaped kitchens
8
PARALLEL WALL KITCHEN
U-SHAPED KITCHEN
9 SINGLE WALL KITCHEN 11 L-SHAPED KITCHEN
ADA + EGRESS REQUIREMENTS
61 | memphis, tn | arc 3546 | spring 2012
9: 4’ minimum width in single wall kitchens
culinary arts school | memphis, tn
mississippi state university | school of architecture
ACCESSIBLE KITCHENS 1: 30” x 48” minimum clear floor space at sinks, work surfaces, and appliances 2: Floor space can extend 19” under sink, work surfaces, and appliances
1
3: At least one shelf in cabinets should be 48” above floor 4: 6-1/2” maximum depth of sink bowl
2
5: Rim of sink and adjacent counter should be adjustable at 28”36” high or fixed at 34” 3
4 5
ACCESSIBLE SINK DIMENSIONS
KITCHENS
2 ACCESSIBLE KITCHENS SECTION 804)
(ADA
6: 60” diameter turning space needed for wheelchairs
One 30” wide minimum work surface required (ADA SECTION 804.3) Kitchen work surface 34” maximum above floor (ADA SECTION 804.3.2)
KITCHEN TURNING SPACE 7
7: If an adjustable surface is used, can range 28”-36” height and usually 36“ deep Clear floor space needed adjacent to dishwasher – open door can’t obstruct the clear floor space for the dishwasher or sink (ADA SECTION 804.6.3) Knee and toe clearance needed at the range – underside should be insulated (ADA SECTION 804.6.4)
Side door ovens need a work surface adjacent to the latch side of the door (ADA SECTION 804.6.5.1) Bottom hinged door oven needs work surface adjacent to one side (ADA SECTION 804.6.5.2)
ADJUSTABLE COUNTER HEIGHT
ADA + EGRESS REQUIREMENTS
63 | memphis, tn | arc 3546 | spring 2012
6
culinary arts school | memphis, tn
mississippi state university | school of architecture
SEATING WHEN DINING 1: If counters are the only provided dining surface than the height of the counter must not exceed 34” in height, and a 60” section of the counter must be made accessible Where tables and seating are built-in at least 5% of the total must be accessible Dining areas are to be accessible for the total floor area allotted for table and seating except for mezzanine areas that contains less than 25% of the total area OTHER ACCESSIBLE FACILITIES 1
Where single toilet facilities occur, at least 50% of those facilities must be accessible 5% of sinks must be accessible, except for service sinks 50% of drinking fountains must be accessible Rooms containing vending and machines must be made accessible
SPECIAL OCCUPANCIES
COUNTER & SEATING DIMENSIONS
AREAS OF ASSEMBLY
2 ASSEMBLY REQUIREMENTS (IBC SECTION 1028)
2 3
3: A main exit is only required for 300+ occupants within an assembly space, but a main exit provides additional safety in the case of an emergency
(a) single space
(b) two spaces
public way
direct to exit
4
4: Balconies having an occupant load of 50 or more are to have two means of egress, from each side of the balcony, with one means of egress leading directly to an exit If an assembly space has a main exit it should be on a public way or have access to a path at least 10’ wide leading to a street or public way WHEELCHAIR SPACES
(a) front or rear entry
ASSEMBLY EGRESS
(b) side entry
WHEELCHAIR SPACE DIMENSIONS
36” wide minimum - 33” if two wheelchair spaces side by side (ADA SECTION 802.1.2) 48” wide minimum if entered from the front or rear - 60” depth if entered from side (ADA SECTION 802.1.3)
ADA + EGRESS REQUIREMENTS
65 | memphis, tn | arc 3546 | spring 2012
2: Second means of egress is required in addition to the main exit of an assembly space. The exit must support half of the total occupant capacity.
SECTION SOURCES Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines. Washington, D.C.: United States Access Board, 2004. Print. Ching, Frank. Building Construction Illustrated. Hoboken, NJ: John Wiley & Sons, 2008. Print. Ching, Frank, and Steven R. Winkel. Building Codes Illustrated. New York: Wiley. 2003. Print. International Building Code. Falls Church, VA: International Code Council, 2006. Print.
In order to understand the physical and social conditions of the site, several aspects of it were documented and analyzed. Areas of analysis helped not only to determine what types of passive strategies are appropriate for the project but also begin to suggest ideas involving materials and the placement of entrances.
3
building code + zoning ADA + egress requirements site inventory + analysis precedent studies + program
culinary arts school | memphis, tn
mississippi state university | school of architecture
CLIMATE | PRECIPITATION
TENNESSEE DISASTERS
7 6 5 4 3 2 1 0
3
131 DECLARATIONS OF DISASTER IN TN (1963 - 2011)
Tornadoes: 21
1950
1960
1970
1980
1990
2000
2010
RECORDED YEARS
Ice Storms: 6 Hurricane Evacuations: 1
Severe Storms: 40
Building fires: 6
High Winds: 7
Straightline Winds: 4
Floods: 41 sources | http://www.fema.gov/news/disasters_state.fema?id=47
Heavy Rains: 3 Flash Floods: 2
SITE INVENTORY+ ANALYSIS
71 | memphis, tn | arc 3546 | spring 2012
NUMBER OF DECLARATIONS
DISASTER RATE IN TN (1963 - 2011)
culinary arts school | memphis, tn
mississippi state university | school of architecture
LAND WATER TO RATIO IN SHELBY COUNTY
HISTORICAL CRESTS FOR MS RIVER AT MEMPHIS 50 45
30 25
RECORDED YEARS
IMPACT + PROBABILITY OF FLOODING AR (Years) > 1,000 500 - 1,000 200 - 500 100 - 200 50 - 100 10 - 50
Population per county 500,000 - 927,644 200,000 - 499,999 100,000 - 199,999 25,000 - 99,999 5,077 - 24,999
Site
WEST SECTION SHOWING BUFFERS 400 300 200 100 0 Water depth: ~20ft.
2009
2003
1997
1991
1985
1979
1973
1967
1961
1955
1949
20 1937
96.29%
35
1943
FLOOD CREST (FT)
40
TORNADOES
35 30 25
FALL - WINTER
NUMBER TORNADOES NUMBER OF INJURIES
20
SPRING - SUMMER
15 10 5 0 1950 YEARS
WEST SECTION SHOWING BUFFERS 400 300 200 100 0
3
NUMBER + IMPACT OF TORNADOES IN SHELBY CO.
Buildings can provide a buffer against strong winds*
Site
1960
19701 0198 01 01990
2000
2010
*ICB 2009 1609.1 p. 315 Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind loads shall not be made for the effect of shielding by any other structures.
SITE INVENTORY+ ANALYSIS
73 | memphis, tn | arc 3546 | spring 2012
STORM DIRECTION + EXPOSURE
culinary arts school | memphis, tn
mississippi state university | school of architecture
EARTHQUAKE ZONES + IMPACT
MISSOURI KENTUCKY
TENNESSEE
ARKANSAS
Site Major Area of Impact
EARTHQUAKES
New Madrid Faultline
Wabash Valley Faultline
Shelby County
Earthquakes
Seismic Zone Three (3)
Seismic Zone Two (2)
Silt = earthy matter, fine sand, or the like carried by moving or running water and deposited as a sediment
Sand = the more or less fine debris of rocks, consisting of small, loose grains Water Table = the planar, underground surface beneath which earth materials, as soil or rock, are saturated with water
DEEP FOUNDATION TYPES Piles • Timber • Composite • H-piles • Pipe • Precast concrete • Cast-in-place concrete • Cased • Uncased • Pedestal • Micropiles
FOUNDATIONS + SOIL
3
Caissons • Cast-in-place concrete • Plain concrete • Reinforced concrete • Socketed • Rock
Note: Liquefaction, a temporary change from solid to liquid, is of particular concern in the Memphis area because of its risk of seismic activity.
Timber
SHALLOW FOUNDATION TYPES Slab on grade Footings • Strip • Column • Wood post • Steel • Reinforced concrete • Stepped • Cantilever • Combined
Foundation walls • Concrete • Concrete masonry
CasedU
H-pile
dUncased
Pipe
Concrete
Micropiles
SITE INVENTORY+ ANALYSIS
75 | memphis, tn | arc 3546 | spring 2012
SOIL TEXTURE IN MEMPHIS, TN
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
50% men women
5.7 7.7% U.S.
Tennessee
Memphis
site zip: 38103
HIERARCHY OF GENDER DEMOGRAPHICS RANGE: FROM U.S. TO SITE ZIP CODE 38103
AGE DEMOGRAPHICS (MEMPHIS) under 5 5-14 15-24 25-34
50,396 102,767 98,593 102,417
7.7% 15.8% 15.2% 5.8%
highest population
35-44 45-54 55-64 65-74 75+
97,060 80,832 47,009 36,730 34,296
14.9% 12.4% 7.2% 5.7% 5.3%
lowest population
12.4%
14.9%
1.
ETHNICITY DEMOGRAPHICS (MEMPHIS) african american caucasian hispanic/latino asian multiple races native american
63.3% 29.4% 6.5% 1.6% 1.4% 0.2%
ASCRIBED DEMOGRAPHICS
site 124 jefferson avenue 29.4%
MS RIVER
MEMPHIS AREA | POPULATION DENSITY BY NEIGHBORHOOD
sources |http://upload.wikimedia.org/wikipedia/en/0/05/Tennessee_population_map.png | http://quickfacts.census.gov/qfd/states/47/4748000.htm
ACHIEVED DEMOGRAPHICS
8.2% 10.6%
COUNTY $0SHELBY - $15,000 53,406 HOUSEHOLDS BY INCOME $15,000 - $24,999 39,706 $25,000 $34,999 40,851 53,406 15.4% $0 - $15,000 11.5% $15,000 --$24,999 $35,000 $49,99939,706 49,548 40,851 11.8% $25,000 - $34,999 $50,000 $74,999 60,856 49,548 14.3% $35,000 - $49,999 17.5% $50,000 --$74,999 $75,000 $99,99960,856 37,294 37,294 10.8% $75,000 - $99,999 $100,000 $149,999 36,637 10.6% $100,000 - $149,999 36,637 $150,000 28,450 28,450 8.2% $150,000 ++
15.4% 11.5%
10.8% lowest value
11.8% 17.5%
14.3%
15.4% 11.5% 1.8% 14.3% 17.5% 10.8% 10.6% 8.2%
EDUCATION OBTAINED EDUCATION OBTAINED 4.7%
grade k-8
grade grade k-8 9-12 grade 9-12 high school high school some college some college associates associates bachelor bachelor graduate graduate
site 124 jefferson avenue 30% 30%
4.7% 9.3%
9.3% 29.0% 23.2% 23.2% 5.8% 5.8% 17.5% 17.5% 10.6% 10.6% 29.0%
SHELBY COUNTY EMPLOYMENT SHELBY COUNTY EMPLOYMENT 525,809 Totalemployees Employees total 525,809 149,47 6 36.6% Blue Collar blue collar 149,476 63.4% 36.6% 258,805 White Collar white collar 258,805 63.4%
MS RIVER
MEMPHIS AREA | HOUSE VALUE BY NEIGHBORHOOD sources | http://www.city-data.com/us-cities/The-South/Memphis-Population-Profile.html | Shelby_County_Demographics.pdf http://www.neighborhoodscout.com/tn/memphis/
36.6%
63.4% 5 mi.
0
N
zach carnegie trey symington assignment 1 | 01.18.12 professors gregory + herrmann arc 3546 | spring 2012
SITE RESEARCH + ANALYSIS
SITE INVENTORY+ ANALYSIS
77 | memphis, tn | arc 3546 | spring 2012
mississippi state university | school of architecture
highest value
3 SHELBY COUNTY HOUSEHOLDS ACHIEVED BY INCOME DEMOGRAPHICS
culinary arts school | memphis, tn
culinary arts school | memphis, tn
mississippi state university | school of architecture
Memphis’s annual violent crime averag- culinary arts school | memphis, tn es to 12,947 incidents. Property crimes mississippi state university | school of architecture in Memphis total 54,130. Memphis crime index is 2, with 100 being the safest. This means that Memphis is safer than 2% of U.S. cities. Memphis . averages 160 crimes per square mile. The national median is 41.8 crimes per square mile.
250% safest
most dangerous
The chances of falling victim to a violent crime in Memphis are 1 in 52, while the chance are 1 in 134 in the state of Tennessee. The chances of being a victim of property crime in Memphis are 1 in 12 and 1 in 23 in Tennessee. MEMPHIS’S RANKING AMONG U.S. CITIES WITH POPULATIONS GREATER THAN 250,000 (74 CITIES) Violent Crime 3rd Murder 20th Rape 12th Robbery 14th Assault 3rd Property Crime 4th Burglary 5th Larceny-theft 8th Motor-vehicle theft 22nd
LIKELIHOOD OF CRIME COMPARED TO NATIONAL AVERAGE
national average datum violent crime rape assault burglary car theft murder robbery property larceny
site 124 jefferson avenue
MS RIVER
MEMPHIS AREA | CRIME RATES BY NEIGHBORHOOD sources | http://www.neighborhoodscout.com/tn/memphis/crime/ | http://en.wikipedia.org/wiki/United_States_cities_by_crime_rate http://homes.point2.com/Neighborhood/US/Tennessee/Shelby-County/Memphis/.aspx
5 mi. 0
N
COURT SQUARE
3 1 Easy-Way COURT Food Store SQUARE 2 BUILDINGS LowensteinNEAR and SITE Brothers Building 3 Lincoln American Tower 1 Easy-Way Food Store 4 Court Annex 2 2 Lowenstein and Brothers Building 3 Lincoln American Tower 5 Old TN Club 4 Court Annex 2 6 Exchange 5 Old TN Club Building 6 Exchange 7 Blue PlateBuilding Cafe 7 Blue Plate Cafe 8 Dr. D.T. Porter Building 8 Dr. D.T. Porter Building
culinary arts school | memphis, tn
mississippi state university | school of architecture
1 JEFFERSON AVENUE
2 SITE 124 JEFFERSON AVENUE
3
4
The buildings denoted here are historically important to this area in both a cultural sense as well as a vernacular sense. The use of masonry and other materials is important to decide on when figuring out what is appropriate for a building on the site chosen.
5
COURT AVENUE MAIN STREET FRONT STREET
8 7
MADISON AVENUE
6
2nd STREET
1
2
3
4
5
6
7
8 1/4 mi.
sources | http://www.commercialappeal.com | http://www.city-data.com/memphis.html
0
300 ft. 0
N
chelsea pierce assignment 1 | 01.20.12 professors gregory + herrmann arc 3546 | spring 2012
SITE RESEARCH + ANALYSIS
N
SITE INVENTORY+ ANALYSIS
79 | memphis, tn | arc 3546 | spring 2012
BUILDINGS NEAR SITE
culinary arts school | memphis, tn
mississippiculinary state university | school of architecture arts school | memphis, tn mississippi state university | school of architecture
1
6
TIMELIN
2
3
7
4
8
1 Calvary E 2 Mallory-N 3 Universit 4 Old TN C 5 TN Brew 6 Dr. D.T. P 7 Beale St 8 Madison 9 Shelby C 10 Exchang 11 Sterick B 12 Old Fede 13 Lincoln A 14 Peabody 15 First TN 16 Morgan 17 AutoZon 18 Cannon C 19 FedEx Fo 20 GE5 Tow 21 Court An
5
9
10
BRICK
STONE
TERRA
GLASS 11
12
13
14
15
16
profes
17
18
19
20
sources | http://ilovememphisblog.com/2011/08/say-cheese-10-locations-for-great-memphis-photo-shoots/ | http://www.burnsland.com | http://www.ontheveryspot.com
21
SITE RESE
VERNACULAR TIMELINE
3 LATE 1800’s
culinary arts school | memphis, tn
mississippi state university | school of architecture
INTERSTATE TATE 40 TA
18
4 1890 - Old TN Club 5 1890 - TN Brewery 1895 - Dr.-D.T. Porter 1900’s Building 6EARLY MID
POPLAR AVENUE A
EARLY - MID 1900’s
FRONT STREET
9
12 16
SITE 124 JEFFERSON AVENUE A
3
MADISON AVENUE A
1900 - Street Beale Street District - Beale District 77 1900 8 1905 - Madison Hotel 8 1905 Madison Hotel 9 1909 - Shelby County Courthouse - Exchange Building County Courthouse 10 9 1910 1909 - Shelby 11 1912 - Sterick Building 101920 1910 - Exchange Building - Old Federal Reserve Building 12 - Lincoln American Tower 13 111925 1912 - Sterick Building 14 1925 - Peabody Hotel
1 13
21 4
6
11 10
8
2
15
2nd STREET 14
UNION AVENUE A
17 2000 - AutoZone Park 18 2003 - Cannon Center for Performing MID 1900’s – RECENT Arts 19 2004 - FedEx Forum 20 2005 - GE5 Townhouses - Court-Annex 21 1520061965 First2 TN Bank
17
BEALE STREET 7 20
MS RIVER
19
5
1/2 mi.
sources | http://www.memphisheritage.org/cms/index.php?q=node/390 | http://www.schmap.com/memphis/sights_historic
12 1920 - Old Federal Reserve Building MID 1900’s - RECENT 13 1925 - Lincoln American Tower 15 1965 - First TN Bank 141985 1925 - Peabody - Morgan Keegan TowerHotel 16
0
1/4 mi 0
16 1985 - Morgan Keegan Tower 17 2000 - AutoZone Park 18 2003 - Cannon Center for Performing Arts chelsea pierce 19 2004 -assignment FedEx | 01.20.12 1Forum professors gregory + herrmann 20 2005 - arc GE5 Townhouses 3546 | spring 2012 21SITE2006 - Court+ ANALYSIS Annex 2 RESEARCH
N
N
SITE INVENTORY+ ANALYSIS
81 | memphis, tn | arc 3546 | spring 2012
1 1844 - Calvary Episcopal Church 2 1852 - Mallory-Neely House TIMELINE 3VERNACULAR 1880 - University of Memphis Law School LATE 1800’s 1890 - Old TNChurch Club - Calvary Episcopal 14 1844 - Mallory-Neely House 25 1852 1890 - TN Brewery 3 1880 - University of Memphis Law 6 1895 - Dr. D.T. Porter Building School
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
BRIC
STON
TERR
GLAS
INTERSTATE 40
AREA POPLAR AVENUE
FRONT STREET
SITE 124 JEFFERSON AVENUE MADISON AVENUE 2nd STREET
UNION AVENUE
BRICK STONE TERRA COTTA GLASS
BEALE STREET
MS RIVER
p 1/2 mi.
AREAS OF INFLUENCE
sources | http://www.memphisheritage.org/cms/index.php?q=node/390 | http://www.memphistravel.com
0
1/4 mi 0
MATERIALS
N
N
SITE
VACANCIES
3 VACANT BUILDINGS VACANT LAND
VACANCIES
culinary arts school | memphis, tn
mississippi state university | school of architecture
BUILDINGS LAND
83 | memphis, tn | arc 3546 | spring 2012
INTERSTATE 40
POPLAR AVENUE
FRONT STREET
SITE 124 JEFFERSON AVENUE MADISON AVENUE 2nd STREET
UNION AVENUE
BEALE STREET
MS RIVER
chelsea pierce assignment 1 | 01.20.12 professors gregory + herrmann arc 3546 | spring 2012
1/2 mi.
sources | http://www.memphisflyer.com/backissues/issue459/cvr459.htm
0
1/4 mi 0
N
N
SITE RESEARCH + ANALYSIS
SITE INVENTORY+ ANALYSIS
culinary arts school | memphis, tn
mississippi state university | school of architecture
PARKING PARKING GARAGES within 0.3 miles wenty-four hour; Monday - Sunday no overnight parking; closed on weekends Parking Lots within 0 miles all are twenty-four; 7 days / week.
PA
culinary arts school | memphis, tn
mississippi state university | school of architecture
PARKING
PARKI tw no we PARKI all
INTERSTATE 40
APARTMENTS + CONDOS POPLAR AVENUE
12 apartments within 0.6 mi 8 one-two bedroom 3 offer studios price range: $475-$1,700 4 one-three bedroom both offer studios price range: $660-$2,310 1 condominium within 0.1 mi one-four bedroom studio price range: $85,000 - $215,000 (purchase only) 10 apartments off the map 3 Mud Island within 3.0 mi 1-3 bedroom $558-$1,790 3 North of Interstate within 2.0 mi 1-3 bedroom $550-$787 4 Southeast of Interstate in 1.8 mi 3 studio, 1-3 bedroom $315-$900 1 one-two bedroom $439-$697
APARTM 12
FRONT STREET
SITE 124 JEFFERSON AVENUE 1
MADISON AVENUE 2nd STREET
10
UNION AVENUE
BEALE STREET
apartm 3 M 13 No 14 So 3s 1o
parkin parkin housin
MS RIVER
p 1/2 mi.
sources | bestparking.com; courtsquarecenter.com; forrent.com
0
parking garage parking lot housing
1/4 mi 0
PARKING + HOUSING
apartm 8 on 3 pri 4 on bo pri condo on stu pri
N
N
SITE R
COMMUNITY RESOURCES
3 6 SCHOOLS
1 elementary school COMMUNITY 3 high schools 1 universityRESOURCES U of Memphis: School of Law 6 SCHOOLS . . . . . . . . 0.3 mi 11 college elementary 3 high schools Concord Career College 1 university
culinary arts school | memphis, tn
mississippi state university | school of architecture
St. Jude’s Children’s Hospital
INTERSTATE 40
0.3 mi. (from site)
POPLAR AVENUE
FRONT STREET
SITE 124 JEFFERSON AVENUE
1LIBRARY LIBRARY . . . . . . . . . . 0.3 mi Cossit CossitLibrary Library
0.3 mi.
1 episcopal
1
MADISON AVENUE
RETAILERS . . . . . . . . .
2nd STREET
RETAILERS famous stores Peabody famous stores - mall Peabody A Schwab
UNION AVENUE
mi
0.6 mi.
- only original store left-mall on Beale A Schwab - dry goods store
Peabody
BEALE STREET
school church library shops
A Schwab
MS RIVER
-only original store left on Beale Street
salena tew
1/2 mi.
sources | google earth
0.5 mi.
0
1/4 mi 0
N
N
assignment 1 | 01.20.12 school professors gregory + herrmann church arc 3546 | spring 2012 SITE RESEARCH + ANALYSIS library shops
SITE INVENTORY+ ANALYSIS
85 | memphis, tn | arc 3546 | spring 2012
U of Memphis: School of Law
college 61 CHURCHES Concord Career College 2 catholic methodist. . . . . . . 0.5 mi 6 1CHURCHES catholic 12 presbyterian methodist 111 lutheran presbyterian lutheran 11 episcopal
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
SURROUND
The main h Memphis and areas include and interstate
ARKAN TENNE
S SA SEE S
MISSISSIPPI RIVER
The site is loca
Barlett - about Memphis.
ARKANSAS
Collierville - a town Memphis
HIGHWAY 40
BARLETT
HIGHWAY 55
Germantown town Memphis
WEST MEMPHIS
SITE
Southaven - ab Memphis
MEMPHIS
HIGHWAY 40
GERMANTOWN
West Memphi downtown Me
COLLIERVILLE
HIGHWAY 40
A SI N S A S SS IP P I
TENNESSEE MISSISSIPPI
TENNESSEE MISSISSIPPI
SOUTH HAVEN
HIGHWAY 55
state border line
K A R IS M
major highways site
profe 10 mi.
CIRCULATION
0
N
SITE RES
CIRCULATION
3 WALKING TIMES
Public Parking Hotels CIRCULATION Grocery Stores
culinary arts school | memphis, tn
mississippi state university | school of architecture
WALKING TIMES
Travel times were computed for a person Site who walks 4 miles per hour. Public Parking
12 Minutes
Hotels
POPLAR AVENUE
Grocery Stores
Travel times were computed for a person who walks 4 miles per hour.
6 Minutes
FRONT STREET 3 Minutes
SITE 124 JEFFERSON AVENUE MADISON AVENUE 2nd STREET
UNION AVENUE
BEALE STREET
tyler baumann assignment 1 | 01.20.12 professors gregory + herrmann arc 3546 | spring 2012
MS RIVER
1/2 mi.
sources | www.matatransit.com
0
1/4 mi 0
N
N
SITE RESEARCH + ANALYSIS
SITE INVENTORY+ ANALYSIS
87 | memphis, tn | arc 3546 | spring 2012
INTERSTATE 40
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
TROLLEY R SHADSHAK AVE
Trolley Sto
OVERTIME AVE
TROLLEY ROUTES
EXCHANGE AVE
Trolley Stop
TRE NS
Monday-Frida Saturday: 6:1 Sunday: 10:15
N ST
REET
T
MAI
SITE 124 JEFFERSON STREET
ERSO
Main S Southbound e
TRE E
ET MAD
ISON
ET TRE
E
FRONT STREET
TH3I RrdD S
ENU
Monday-Thursday: 6:25 AM - 11:15 PM Friday: 6:25 AM - 12:25 AM Saturday: 9:00 AM - 12:45 AM Sunday: 10:00 AM - 6:00 PM
Monday-Thur Friday: 6:25 A Saturday: 9:0 Sunday: 10:00
TRE COU RT A V
MAIN STREET LINE Southbound every 10 minutes
SEC O 2N nd DS
Monday-Friday: 6:00 AM - 10:50 PM Saturday: 6:10 AM - 12:45 AM Sunday: 10:15 - 5:55 PM
JEFF
N FR ONT S
MADISON AVENUE LINE Outbound every 16 minutes
ET
Madiso Outbout ever
ORLEANS STREET DUNLAP STREET
AVE N
UE
PAULINE STREET CLEVELAND STREET
RIVERFRONT LINE Every 13 minutes
Riverfr Every 13 min
Monday-Thur Friday: 9:15 A Saturday: 9:0 Sunday: 10:00
BEALE STREET HULING AVE BUTLER AVE G. E. PATTERSON AVE
Monday-Thursday: 9:15 AM - 11:00 PM Friday: 9:15 AM - 12:30 AM Saturday: 9:00 AM - 12:45 AM Sunday: 10:00 AM - 6:00 PM
prof 1/2 mi.
sources | www.matatransit.com
0
600 ft. 0
CIRCULATION
N
N
SITE RE
CIRCULATION
3 TRANSPORTATION ROUTES
major roads and highways (based off autombile frequency) CIRCULATION
culinary arts school | memphis, tn
mississippi state university | school of architecture
bus route
TRANSPORTATION ROUTES
hwy 40
bus route
hwy 40
trolley route 2
trolley route 1
st
trolley route 2 bicycle tour route
fron t
bycicle tour route
pop
dan ny th oma s
blvd
2nd
st
lar a ve
SITE 124 JEFFERSON STREET
pop
lar a ve
jeffe rso
2nd
st
fron t st
n av e
unio
bea
ny th
oma
s blv d
n av e
le s
st
dan
t
fro nt
unio
n av e
beale st
tyler baumann assignment 1 | 01.20.12 professors gregory + herrmann arc 3546 | spring 2012
MS RIVER
1/2 mi.
sources | www.matatransit.com
0
1/4 mi 0
N
N
SITE RESEARCH + ANALYSIS
SITE INVENTORY+ ANALYSIS
89 | memphis, tn | arc 3546 | spring 2012
major roadtrolley route 1
hwy 40
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
FO
Th lin bu th
Gr fo be no ob
27
FOOT TRAFFIC SITE
The site is located just off of a busy trolley line. Due to the frequent stops and the bustling strip the trolley is on, the site sees the potential for a lot of foot traffic. Graphically laid out here is the average foot traffic for a one hour time span between the hours of 3PM - 4PM. Also noted are the types of people who were observed utilizing the trolley thoroughfare.
87
52
Heaviest Foot Traffic Medium Foot Traffic Lowest Foot Traffic ……………………..Security=1 X2 ………………..Children=4 X2 ………………..Tourist=32 X2 ………………..Trolley Passenger=41 X2 ………………..Community=86
PEDESTRIAN CIRCULATION
100 feet
350 feet 0
0
N
N
VEHICULAR VOLUME
3
VEHICLE RESEARCH
culinary arts school | memphis, tn
mississippi state university | school of architecture
VEHICLE DATA
H
H 195 VP
FRONT STREET
JAN. 27 2012: jefferson avenue:
220 VPH
25 V P
ADAMS STREET
7:45PM-8:15PM
driving east = 1 driving west = 2
2nd street:
driving south= 19
80 V P
JEFFERSON AVENUE
H
JAN. 28 2012 : adams avenue:
H
2:35PM-3:05PM
91 | memphis, tn | arc 3546 | spring 2012
50 V P
driving east = 1 driving west = 2
driving north = 9 driving south= 10
H
VP H
jefferson avenue:
driving east = 2 driving west = 2
200
40 V P
240 VP
215
H
VPH
front street:
SITE 124 JEFFERSON AVENUE
2nd street:
driving south= 12
court avenue:
20 V P
driving east = driving west = 1
H
3rd avenue:
driving north= 10
2nd STREET
COURT AVENUE
H
280 VP
H
35 V P
AVERAGE VEHICLES ALONG JEFFERSON AVENUE + 2nd STREET: taxis: 12 horse carrages: 2
10 V P
220
VPH
3rd STREET
VPH = vehicles per hour
VPH = vehicles per hour
H
300 ft.
0
0
300 ft.
N
N
jared brown eric lynn andrew macmahn kristin perry chance stokes assignment 2 | 02.06.12 professors gregory + herrmann arc 3546 | spring 2012
SITE RESEARCH + ANALYSIS
SITE INVENTORY+ ANALYSIS
SECTION SOURCES http://travel.aol.com/travel-guide/united-states/tennessee/memphis-photo-m-bridge-pid-6038665/ http://www.memphisheritage.org/cms/index.php?q=node/390 http://www.schmap.com/memphis/sights_historic/ http://ilovememphisblog.com/2011/08/say-cheese-10-locations-for-great-memphis-photo-shoots/ http://www.burnsland.com http://www.ontheveryspot.com http://ilovememphisblog.com/2011/08/say-cheese-10-locations-for-great-memphis-photo-shoots/ http://www.memphisflyer.com/backissues/issue459/cvr459.htm http://www.commercialappeal.com http://www.city-data.com/memphis.html http://www.flickr.com/photos/midge3426/3902447397/ http://www.courtsquarecenter.com/LAT-commercial.php http://www.downtownmemphis.com/ http://www. bestparking.com http://www. courtsquarecenter.com http://www. forrent.com http://www. mudisland.com http://www. memphisriverfront.com http://www. visitsouth.com http://www. yelp.com http://www. memphis.about.com http://www. memphistravel.com http://www. peabodymemphis.com http://www.matatransit.com http://www.city-data.com/us-cities/The-South/Memphis-Population-Profile.html http://pubs.usgs.gov/fs/2003/fs068-03/images/map.gif http://www.neighborhoodscout.com/tn/memphis/ http://upload.wikimedia.org/wikipedia/en/0/05/Tennessee_population_map.png http://quickfacts.census.gov/qfd/states/47/4748000.html http://www.neighborhoodscout.com/tn/memphis/crime/
http://en.wikipedia.org/wiki/United_States_cities_by_crime_rate http://homes.point2.com/Neighborhood/US/Tennessee/Shelby-County/Memphis/.aspx http://usa.windspot.es/ http://www.wcc.nrcs.usda.gov/ftpref/downloads/climate/windrose/tennesee/memphis/ http://www.wholesalesolar.com/products.folder/module-folder/kyocera/KD135GX-LPU.html http://www.bestplaces.net/climate/ http://www.bestplaces.net/climate/ http://en.wikipedia.org/wiki/Roof_garden http://www.fema.gov/femaNews/disasterSearch.do http://2010.census.gov/news/img/cb11cn93_tn_totalpop_2010map.jpg http://andrewgelman.com/movabletype/mlm/tennessee.png http://en.wikipedia.org/wiki/Shelby_County,_Tennessee http://www.srh.noaa.gov/ohx/?n=may2010epicfloodevent http://www.mcallenedc.org/images/tornado-activity.jpg http://radar.weather.gov/Conus/index_loop.php http://www.wbdg.org/design/resist_hazards.php#recomd http://www.tornadohistoryproject.com/tornado/Tennessee/Shelby/table http://earthquake.usgs.gov/earthquakes/states/tennessee/history.php http://standeyo.com/NEWS/09_Earth_Changes/090929.New.Madrid.worries.html http://www.wbdg.org/design/resist_hazards.php#recomd
This project focuses on a culinary arts school, and so it is very specialized and calls for special types of planning and equipment. In order to better understand how to deal with this program, students were to research previous culinary arts schools and how they dealt with similar programs. The influences of cuisine were also observed in order to better decide what type of restaurant should be held within the building. General curriculums of standing culinary arts schools were discussed so that students could better understand what was required of the program. Organic agricultural methods were also analyzed so that students would begin to incorporate those methods into their design.
4
building code + zoning ADA + egress requirements site research + analysis precedent studies + program
culinary arts school | memphis, tn
mississippi state university | school of architecture
CLIMATE Globally, cuisine is directly affected by climate since it has such a large influence on the crops that can grow in that area and therefore, the ingredients available for food. Climate affects the supply of food for cooking and dictates the raw materials that are accessible. Although climate is not the only factor that shapes cuisine, traditionally it was a primary instrument in creating dishes. As the world has developed, economic conditions also attribute to different cuisine styles. The economic conditions of a country entails the extent of food distribution and trade, which allows different regions the freedom to not rely solely on the agriculture and meats of one specific environment HUMID + WARM ARID + HOT HUMID + TROPICAL COLD
GLOBAL INFLUENCES
INFLUENCE ON SOUTHERN CUISINE
4 CROPS + MEAT + PREPARATION
FRANCE foods: chicken, cultivated white and sweet potatoes, lima beans, cows, dairy methods: roux based foods were introduced, utilitarian kitchens included a kettle, hearth, and possibly a cast-iron skillet
SPAIN foods: pork, sheep, wines, olive oil, rice methods: brought the use of cooked onions, peppers, tomatoes, and garlic, variations of seafood, Mediterranean cuisine
EARLY 1500s 1492
CHRISTOPHER COLUMBUS DISCOVERED AMERICA
1493
SPAIN TRAVELED TO AMERICA, INTRODUCING MEDITTERANEAN CUISINE
16TH CENTURY
1520s
NATIVE AMERICANS EUROPEANS SPAIN INTRODUCED TAUGHT BROUGHT HORSES, RICE TO THE IMMIGRANTS HOW CATTLE, AND HOGS AMERICAS TO PREPARE CROPS
1565
SPAIN SENT THEIR FIRST PERMANENT SETTLERS
1682
EUROPEAN OCCUPATION OF LOUISIANA. CREOLE CUISINE AND AFRICAN INFLUENCE BEGAN
1619
SLAVERY WAS INTRODUCED AS WELL AS EXPORTS FROM AFRICA
1796
TENNESSEE WAS ADMITTED AS THE 16TH STATE
1750s
MID 1800s
FRENCH SETTLERS (ACADIANS) INTRODUCED CAJUN CUISINE TO LOUISIANA
RICE WAS INTRODUCED TO SOUTHERN CUISINE
NATIVE AMERICANS foods: corn, pumpkins, squash, beans, sassafras, wild berries and grain, all peppers, cow peas, tomatoes methods: pit barbequing, preservation of meats and vegetables, growing and harvesting corn, hunting, planting, and food processing
PRECEDENT STUDIES + PROGRAM
97 | memphis, tn | arc 3546 | spring 2012
AFRICA foods: field peas, okra, eggplant, peanuts, yams, watermelon, rice, black eyed peas, okra methods: frying, steaming in leaves, grilling, roasting, baking, boiling
culinary arts school | memphis, tn
mississippi state university | school of architecture
SOUTHERN REGION For southern hospitality food is a way of life. It evokes memories of good times and fun gatherings. It’s what brings people home and what connects people from different backgrounds together.
|
Raleigh
ALABAMA, NORTH CAROLINA, TENESSEE, TEXAS: BBQ. LOUISIANA: home to tabasco sauce and the largest consumer of crawfish in the US. gumbo: many variations...okra, chicken, sausage, vegetable, turtle, etc. boudin: typically made with pork, rice, onions, and spices wrapped in a sausage casing. MISSISSIPPI: Delta Region- melting pot of cultures hot tamales: adapted from Mexican migrant workers that came to work in cotton fields-cheap and portable-made from corn meal and pork. catfish: MS is the largest distributor in the country. Coastal Region- home to seafood as well as influences from around the world. Tamales Seafood Boudin/Gumbo Catfish BBQ
CULTURAL CUISINE
MEMPHIS Little Rock
Tupelo Greenville
Atlanta
Charleston
Birmingham
Jackson Pensacola
Baton Rouge Austin
Lafayette
Biloxi New Orleans
Gulf of Mexico
tamales
boiled shrimp
boudin
fried catfish
bbq ribs 200 mi.
N
BARBEQUE TRAIL
MEMPHIS
Charolette
Nashville
Columbia
Little Rock
Tupelo Greenville
Atlanta Birmingham
Jackson
Baton Rouge Austin
Lafayette Houston
jacksonville
Pensacola Biloxi
orlando New Orleans
tampa
Gulf of Mexico Miami
thickness of circle refers to density of bbq joints size of circle refers to the expanse of the bbq joints
200 mi. 0
4 N TX:
beef brisket, sausage = most popular cooked over oak wood at 600 F. no traditional sauce and often no sauce
PRECEDENT STUDIES + PROGRAM
99 | memphis, tn | arc 3546 | spring 2012
Raleigh
AL: North: white BBQ sauce + chicken Birmingham: thick sauce; pork shoulder, butt, ribs, beef brisket East: orange sauce; mustard, tomato in thin vinegar FL + LA: gator BBQ GA: origin of Brunswick stew with BBQ KY: mutton BBQ + burgoo MS: mostly pork with tomato sauces cooked over hickory or charcoal NC: east: whole hog BBQ + west: hog shoulder sauce of vinegar + cayenne pepper; side dish of Brunswick stew or boiled potatoes west: side dish of hush puppies, origin of slaw on sandwich (German) SC: origin of mustard sauce TN: East: smoked hog shoulders Southwest: whole hog, slaw on sandwiches; lots of smoked pork options; density of BBQ joints increases Memphis: “Urban Heart of BBQ Belt” smoked pork is shoulder in stead of whole hog or dry ribs.
mississippi state university | school of architecture
culinary arts school | memphis, tn
CORE COOKING METHODS
CULINARY FUNDAMENTALS
BAKING ESSENTIALS
ADDITIONAL COURSES
CULIN
mississippi state university | school of architecture
CULINARY SKILLS Culinary Fundamentals- basic culinary arts skills are taught first, how to properly use different kitchen knives, how to properly sanitize equipment and food, identifying different food products, learning about ratios, ingredient scaling, and unit conversations, how to design a plate, learning the science of food and how nutrition affect menus and dishes Core Cooking Methods- classes in creating classic sauces and how to combine them, how to mix soups, sautéing different dishes, deep-frying, grilling, preparing seafood, using a variety of grains and vegetables, preparing egg dishes, working with griddles, mixing salads, making classic sandwiches, learning how to cook food from around the world and the art of wine tasting Baking Essentials- how to mix, bake, stack and frost different types of cakes, and pastries, how to make different confections and how to temper chocolate Additional Courses- these courses include classes in managing a restaurant, developing a good menu, a student’s final cooking exam, and the opportunity to receive a job in the culinary field *all culinary schools teach approximately the same courses
TEACHING THE CULINARY ARTS
knife skills
food safety
grand sauces
compound sauces
soups
sauteing
doughs
pastries
culinary management
menu development
product identification
culinary math
deep-fried foods
grilled foods
sea food preperation.
grain + vegetable
confections
cakes
food exam
internships
plate development
gastronomy
egg preperation
griddle specialties
salads
sandwich preperation
chocolate tempering
international foods
wine studies
nutrition
*all culi the sam
P
sources | http://www.ciachef.edu | http://www.iceculinary.com | http://www.lecoleculinaire.com/ | http://www.artinstitutes.edu/Phoenix | http://www3.austincc.edu
COOKS’ AREAS OF EXPERTISE site presentation
supervision
cashier work
production management
Culina culinary properl to prop identify learning and uni plate, le how nu Core C creating combin sautéin grilling, variety prepari griddles sandwic from ar tasting Baking stack an and pas confect Additio include develop cooking receive
business management
logistics
work environment
cleaning and maintaining equipment
presentation skills
service
culinary production
preparing assembling foods traditional and asssessing bids from preparing staff according to professional personalization of issuing additional diversified foods suppliers paysheets cleaning and regulations interior decor invoices organizing estimating future of equiptment training offering nutritional special orders customer-visits advice & diet menus preparing modulating implementing collecting customer managing display assembly-style hot checking invoices composition, & food safety payments boards and cold foods to be paid presentation regulations mass service reminding team of keeping track of customer cleaning premises of a single managing stock production flow and orders and tables food item and orders objectives
101 THINGS I LEARNED IN 101 T CULINARY SCHOOL IN C
culinary arts school | memphis, tn
mississippi state university | school of architecture
TOOLS OF THE TRADE
griddle: a heavy piece of cooking equipment with a continuous, flat surface
grill: an open grid on sauciers: these pans are best which foods can be directly for sauces and creamy foods. The tapered cross section has exsposed to fire no corners where food could hide and burn
irrigation supply
skillets: useful for browning/caramelizing and for reducing sauces. the low, flared sides help with evaporation
FOOD SHAPE COUNTERPOINTS
drainage from roof
black water (to sanitary sewer)
GREY WATER RECYCLING FOR KITCHENS
4
saucepans: these pans are saucepans: these pans used most often for basic heating are used most often for and boiling and have a squared basic heating and boiling cross section
non-potable water supply grey water treatment
sources | Eguaras, Louis, and Matthew Frederick. 101 Things I Learned in Culinary School. New York: Grand Central Pub., 2010. Print.
holding tank
fact: Goats discovered coffee (an ethiopian farmer noticed his goats getting agitated after eating coffee berries)
Mise en Pla its place” - i allows one situation in There are o Dry cooking deep-frying Wet cooking boiling, sim 101 | memphis, tn | arc 3546 | spring 2012
paring knife: 2-4” blade, used to cut fruits and vegetables boning knife: 5-7” blade, used to remove meat from a carcass. fillet knife: 5-8” blade, used for filleting fish french (chef’s) knife: 8-14” blade, versatile knife used for chopping, slicing, dicing, and mincing serrated slicer: 12-14” jagged, toothed blade used to cut bread and tomatoes
IMPORTA FOR CUL
EIGHT W LOOK BE
1: use groupings a 2: avoi at varying h 3: use colored plat sometimes 4: use square, tria negative sp 5: use with clear g arrangemen 6: use shapes, colo arrangemen 7: add contrasting edible 8: pain “paint” the p
PRECEDENT STUDIES + PROGRAM
pr
PRE
• Located in the city of Birmingham, AL • Non-profit organization that has successfully transformed over 3 acres of vacant downtown property into an urban teaching farm
culinary arts school | memphis, tn
mississippi state university | school of architecture
GUSTORGANICS culinary arts school | memphis, tn
• Is first and only certified organic restaurant in New York • Is world’s first certified restaurant using all organic ingredients • Is one of the “greenest” restaurants in the world • The first and only USDA certified organic bar on the planet • 100% organic restaurant & bar open 365 days a year for breakfast, lunch, brunch, and dinner
mississippi state university | school of architecture
USE OF LOCAL PRODUCE:
ORGANIC OPTIONS: USE LOCAL PRODUCE
GUSTO
The restaurant utilizes produce grown by local farmers and gardeners.
• First an restaur • World’s organic • One of world • The firs bar on • 100% o days a and din
SUSTAINABLE PRACTICES OF GUSTORGANICS • Recycling and composting • Use only wind energy and solar lighting • Energy efficient kitchen equipment • Water conservation equipment • Biodegradable take out containers, cups and flatware • Environmentally friendly packaging (Most is biodegradable) • 100% recycled paper, bags and boxes • Printing with soy ink • Green cleaning practices including biodegradable products • Built the restaurant with recycled woods and eco friendly materials • Organic uniforms • Use of organic flowers
O US
SUSTAI
Restaurant
Farm/Garden
sources | http://www.gustorganics.com/greenandorganic_ourquality.php
• Recycli • Use on • Energy • Water c • Biodeg and flat • Environ (Most i • 100% r • Printing • Green c biodegr • Built ou and eco • Organic • Use of
PR
ORGANIC OPTIONS : OFF-SITE FARM/GARDEN
4 SUMMER JO’S
culinary arts school | memphis, tn
mississippi state university | school of architecture
OFF-SITE FARMING: The restaurant utilizes produce grown in their own farm or garden.
ORGANIC OPTIONS:
• OFF-SITE Located near Grants Pass, Oregon FARM/GARDEN • Pizzeria and artisan bakery JO’S • SUMMER USDA Certified organic farm supplies • Located near Grants Pass, Oregon
“GREEN” • Pizzeria and EXPRESSIONS artisan bakery
Restaurant
Farm/Garden
• “GREEN” Contributes to the Renewable EXPRESSIONS Northwest Project • Contributes to the Renewable Northwest • Produce is also sold in local markets Project •and Produce issite also sold in local markets and on at the Farm Stand on site at the Farm Stand • •Participates the international Woof Participates in thein international Wwoof Program, which enables people to learn Program, which enables people to first-hand about organic growing learn first-hand about organic growing techniques • Gardens contain wide range of herbs techniques and flowers that are both used in the • Gardens contain wide restaurant and are also for sale range of herbs and flowers that are both used in the restaurant and are also for sale
kristin perry assignment 2 | 01.27.12 professors gregory + herrmann arc 3546 | spring 2012
sources | http://summerjos.com/pizza/
PRECEDENTS + PROGRAM
PRECEDENT STUDIES + PROGRAM
103 | memphis, tn | arc 3546 | spring 2012
• USDA Certified organic farm supplies
culinary arts school | memphis, tn
mississippi state university | school of architecture
culinary arts school | memphis, tn
mississippi state university | school of architecture
UNCOMMONGROUND • Casual dining restaurant located in Chicago • Nation’s first certified organic rooftop farm • The independently-owned and operated restaurant produces no waste, powers its vehicle with used fryer oil, harnesses the sun to heat their water, and feeds customers with locally sourced, sustainably produced products, as well as products from their own rooftop farm.
U
ON-SITE FARMING: The restaurant utilizes produce grown in a garden or farm on, under, or inside the building.
•
•
•
M
• • Restaurant
Farm/Garden
• • •
MORE “GREEN” METHODS • Recycling program • Community outreach via outside partnerships and events held on-site • Educational outreach • Biking and walking to restaurant • The Growing Connection • “Grassroots project... [that] links people and cultures in a...campaign that introduces low-cost water and efficient + sustainable food growing innovations hand in hand with access to technology”
ORGANIC OPTIONS: ON SITE FARM/GARDEN
sources | http://www.uncommonground.com/
ORGANIC FARMING METHODS
mississippi state university | school of architecture
grow and yield more fruit.
BENEFITS INCLUDE: BENEFITS INCLUDE:
Grow Tray
Nutrient Return
Reservoir Nutrient Pump
Air Stone
Air Pump
•• Soil is not needed Soil is not needed •• Water stays the and system and is Water stays in thein system is reused and recycled, thusrecycled, lowering thethus cost lowering reused and • It is possible to control nutrition levels in water costs their entirety, thus lowering nutrition • Itcosts is possible to control nutrition levels • No nutrition pollution is released into the in their entirety, lowering nutrition environment because ofthus the closed system costs Stable and high yields (30% - 50% more) ••• No nutrition pollution is released Pests and diseases are easier to get rid into environment because of the of thanthe in soil • closed Easier to harvest system • No pesticide damage • Stable and high yields (30% - 50% more) • Pests and diseases are easier to get rid of than in soil • Easier to harvest • No pesticide damagenick purvis assignment 2 | 01.27.12 professors gregory + herrmann arc 3546 | spring 2012
sources | www.hydroponics.net/learn/hyrdoponic_gardening_for_beginners.asp
PRECEDENTS + PROGRAM
PRECEDENT STUDIES + PROGRAM
105 | memphis, tn | arc 3546 | spring 2012
4 HYDROPONICS ORGANIC FARMING METHODS Hyrdoponics is an alternative method used to grow plants in nutrient rich water, HYDROPONICS rather than using soil. Plants do not have is an alternative methodthe usedsoil to find toHyrdoponics use energy to search to grow plants in nutrient rich water, rather the nutrients. Intoausehydroponic than required using soil. Plants do not have energy to plants search can the soil find extra the system, usetothat energy required nutrients. In a hydroponic tosystem, growplants andcanyield more fruit. to use that extra energy
culinary arts school | memphis, tn
use significantly less water.
culinary arts school Benefits are identical | memphis, to those tn of
mississippi state university | school of architecture
hydroponic systems.
culinary arts school | memphis, tn
mississippi state university | school of architecture
AEROPONICS
nick purvis assignment 2 | 01.27.12 gregory + herrmann Similar toprofessors the concept of hydroponics, | spring arc 3546 aeroponically grown plants are 2012 grown
PRECEDENTS + PROGRAM using no soil and little to no water. Rather than being continuously submerged in water, the roots are suspended in mid-air and continuously or periodically sprayed with a nutrient rich solution.
Spray
Spray
Nutrient Water Pump
Grow Tray
Unlike hyrdoponics, aeroponic systems use significantly less water. Benefits are identical to those of hydroponic systems.
ORGANIC FARMING METHODS
sources | home.howstuffworks.com/lawn-garden/professional-landscaping/alternative-methods/aeroponics.htm
ORGANIC M ORGANIC FARMING
s school | memphis, tn
university | school of architecture
METHODS
THE LIVING MACHINETHE LIVING MACHIN
4
107 | memphis, tn | arc 3546 | spring 2012
The Living Machine, crea The Living Machine, created by Worrell Water Technologies, is a Water Technologies, is an eco friendly waste water treatment sy waste water treatment system. It waste water and filters it collects waste water and tanks filtersfilled it through with soil and p various tanks filled with on soiltheand plants while at nutrients, which feed on the nutrients, whileand at disinfecting the cleaning t same time, cleaning and disinfecting the water. Since the system uses pla
water, farmers or restaura
1. Influent black water or grey water
2. Primary Tank
Small Growbed With Mint
Biofilter
3. Recirculation Tank
4. Stage 1 Tidal Flow Wetlands
5. Stage 2 Vertical Stage Wetlands
6. Effluent reuse for toilets, irrigation, cooling towers, etc.
Duckweed Tank
as antoopportunity Since the system uses plants clean the to grow could produce fruit or herb water, farmers or restaurants could use it as an opportunity to grow small plants that could produce fruit or herbs. AQUAPONICS
AQUAPONICS
Aquaponics systems ta Machine one step further: Aquaponics systems take The Living the tanks for cultivating. Machine one step further: adding fish provid the fish produce into the tanks for cultivating. The dirty nutrients needed to grow.
water the fish produce provides plants with nutrients needed to In grow. general, warm, fresh w
do best in aquaponic sys
Vortex Filter
proven to In general, warm, fresh have waterbeen fish tend largemouth to do best in aquaponictilapia, systems. Fish bass, a that have been proven to flourish include tilapia, largemouth bass, and even catfish.
Growbed
Fish Tank Pressurized Water Feed Gravity Fed Return
.livingmachines.com/about/how_it_works/
Small Fry Tank
Solids Lifting Overflow
Pump Sump Tank
assignm professors greg arc 35
PRECEDENTS
PRECEDENT STUDIES + PROGRAM
culinary arts school | memphis, tn
mississippi state university | school of architecture culinary arts school | memphis, tn
mississippi state university | school of architecture
WOOLY POCKETS 1. Made from recycled material. The pockets allow plant roots to breathe and farmed hydroponically or aeroponically with pumps. Pockets are fitted around corners, walls, and windows
PLANT SHELVES 2. Plants are supported by shelves and farmed hydroponically or aeroponically with pumps. Shelf size dependant on plant size and sunlight exposure. PLANTER WALL BOX 3. Systems that use multiple plant levels and use either hydroponics or aeroponic pumps to farm. The boxes are durable and space-saving, but not very versatile.
1
2
3
4
5
6
HANGING GARDENS 4. Plants are suspended in the air and are farmed aeroponically. Plants are grown efficiently. MESH GARDENS 5. Plants are grown vertically through a mesh material and farmed aeroponically Meshes are able to turn corners and be fitted almost anywhere.
CONVENTIONAL PLANTERS Plants are grown with sources any | www.garden-design-pictures.com/green-walls.html | www.reallynatural.com | www.greenroofs.com | www.motherearthnews.com | www.greenlivingideas.com 6. technique in conventional containers.
ONSITE FARMING
RESTAURANTS
4 KITCHEN FLOW
RESTAURANTS Incoming Supplies
culinary arts school | memphis, tn
mississippi state university | school of architecture
BAR
DRY STORAGE RECEIVING
FINAL PREPARATION
PREPARATION REFRIGERATED STORAGE
LOUNGE
ENTRANCE / EXIT
CUSTOMER WAITING
HOSTESS
KITCHEN FLOW
Issued Supplies Incoming Supplies
Finished Food Issued Supplies
WARE WASHING
SERVICE
DINING
DINING
CASHIER
KITCHEN FLOW
CUSTOMER FLOW
CUSTOMER FLOW
CUSTOMER FLOW
Entry
Entry
ExitExit
Waiting Spaces
Waiting Spaces
1. Dry Storage 2. Refrigerated Storage 3. Food Preparation 4. Ware Washing 5. Waste Disposal 6. Entrance / Exit 7. Hostess 8. Bar 9. Lounge 10. Dining
8
3
4 10
9
2
5
1
7
6
THE EYRE BROTHERS PLAN sources | Birchfield, John C. “Design and Layout of Foodservice Facilities” (NewYork: Van Nostrand Reinhold, 1988) Farrelly, Lorraine. “Bar and Restaurant Interior Structures” (England: Wiley-Academy, 2003)
The Eyre Brothers
London, UK TheLocation: Eyre Brothers Architect + Designer: Waugh Thistleton Location: London, UK Architect + Designer: Waugh Thistleton
tyler baumann andrew mcmahan john thomas assignment 2 | 01.27.12 professors gregory + herrmann arc 3546 | spring 2012
PRECEDENTS + PROGRAM
PRECEDENT STUDIES + PROGRAM
109 | memphis, tn | arc 3546 | spring 2012
Finished Food
WASTE DISPOSAL
culinary arts school | memphis, tn
mississippi state university | school of architecture
CULINARY ART SCHOOL Gracia Studio Tijuana, Mexico | 2010 1: Student work stations divided into four different rooms, each with two shared work station areas 2: Transition space volumes ‘The Grand Plaza’
between
12
3
3: Administrative office - located along perimeter of building to allow for natural lighting conditions 4: Student lounge located in close proximity to the ‘Grand Plaza’ 5
4
5: Small auditorium with benched stadium seating 6: Wine cellar - no direct light into the space, but natural light washes far wall ENERGY EFFICIENCY HVAC system can’t exhaust from kitchens so divided in two | one for auditorium, one for two classrooms Student Work Stations | 1,100 sq ft each Offices | 900 sq ft Student Lounge | 900 sq ft Auditorium | 1,000 sq ft Circulation | Outdoor spaces | 5,550 sq ft
CULINARY ARTS SCHOOLS
PLAN DIAGRAM
6
CULINARY ARTS SCHOOLS
4 INSTITUTE FOR THE CULINARY ARTS HDR Architects Metropolitan Community College Omaha, Nebraska | 2009
3
2: Demonstration Lab | theater style classroom space 3: Main lobby clad in zinc and wood-look laminate
5
4
4: Sage Student Bistro | dining space open to the public 5: Theory Labs | main teaching areas - two identical kitchens
ENERGY EFFICIENCY
15,000 gallon collection tank used to store rainwater that is reused for irrigation Student Resources | Admin | 3,068 sq ft Labs | 1,520 sq ft each Ingredient Storage | 1,900 sq ft Bakery & Kitchen | 4,731 sq ft Bistro | 1,950 sq ft
PLAN DIAGRAM
PRECEDENT STUDIES + PROGRAM
111 | memphis, tn | arc 3546 | spring 2012
2
1
1: Materials include prepatinated copper panels, brick, low iron transparent and glass, copper flashing
culinary arts school | memphis, tn
mississippi state university | school of architecture
TEACHING ASSISTANT(S)
LIBRARIAN
FACULTY
LIBRARY STAFF
GUEST LECTURER
GUEST DEMONSTRATOR
STAFF T CULINARY ART SCHOOL
STUDENTS
MAINTENANCE DIRECTOR EC CAREER SERVICES PERSONNEL
ADMINISTRATORS STAFF
This is a breakdown of the different types of clients and users that would access the Culinary Arts School portion of the building.
CULINARY SCHOOL CLIENTS AND USERS
ADMISSIONS PERSONNEL
SECRETARY(S)
RESTAURANT CLIENTS AND USERS
culinary arts school | memphis, tn
mississippi state university | school of architecture
SOUS-CHEF LINE COOK
RESTAURANT
MANA MANAGER SERVERS
BUSSER(S)
HOSTES HOSTE S HOSTESSES
STOCKER(S)
BARTENDERS
BAR BACK(S)
CUSTOMERS
CATERING TERING SERVICE SE WASTE ASTE REMOVAL REM CLEANING SERVICES SE THIRD PARTY
SECURITY FOOD DELIVERY DELIVE INSPECTORS INSPECT INSPEC EXTERMINATORS EXTERMINA EXTERMIN
4
This is a breakdown of the different type of clients and users that would access th restaurant portion of the building.
PASTRY CHEF T TAFF STAFF
RESTAURANT DIVISION
113 | memphis, tn | arc 3546 | spring 2012
EXECUTIVE CHEF
This is a breakdown of the different types RESTAURANT of clients and users that would access CLIENTS + USERS the restaurant’s portion of the building.
program group assignment 2 | 01.25.12 professors gregory + herrmann arc 3546 | spring 2012
PRECEDENTS + PROGRAM
PRECEDENT STUDIES + PROGRAM
culinary arts school | memphis, tn
mississippi state university | school of architecture
150
138
OCCUPANT LOAD
120 100
90 60 44 32
30
18 3
AO................ADMISSIONS OFFICE BS.................................BAKE SHOP CR...............................CLASSROOM CS.....................CAREER SERVICES DL..............DEMONSTRATION LAB DS.....................DIRECTOR’S SUITE FA...........................FACULTY AREA LH...........................LECTURE HALL LI........................................LIBRARY PK........................PASTRY KITCHEN RA........................RECEIVING AREA RT..............................RESTAURANT SF..............................STAFF ROOM ST.....................STUDENT LOUNGE TK.................TEACHING KITCHENS WR..............................WINE ROOM
OCCUPANCY LOAD VS. SQUARE FOOTAGE
0 1000 ft²
26
AO
350
600
CR
CS
DL
300 900
22
4
2 BS
DS
FA
400
400
LH
3000 ft²
LI
36
16 6
3
PK
RA
2 RT
SF
250
900 1500
2000 ft²
30
1250
900
ST
TK
450
650
1800 3000
4000 ft² 5000 ft² 6000 ft² 7000 ft² 8000 ft²
TOTAL SQUARE FOOTAGE: 27625 SF
WR
7500
ALTERNATE ROOM REQUIREMENTS
MECHANICAL ROOM REQUIREMENTS
Temperature
50-60°F
Humidity Total Building Square Footage
50-70%
Cooling Strategy (based on hot/humid climate)
Room Location (based on hot/humid climate)
Insulation
500 SF
Boiler room
100 SF
Space for cooling towers
Vapor Barrier
Light Requirements
38 SF 21 SF Main supply or return ducts Branch supply or return ducts
Floor Type
Active
R-19
R-30
PRECEDENT STUDIES + PROGRAM
115 | memphis, tn | arc 3546 | spring 2012
30,000 SF
4 WINE ROOM REQUIREMENTS
SECTION SOURCES Eguaras, Louis, and Matthew Frederick. 101 Things I Learned in Culinary School. New York: Grand Central, 2010 Meriot, Sylvie-Anne. Nostalgic Cooks Farrelly, Lorraine . Bar and Restaurant Interior Structures (England: Wiley-Academy, 2003) Bircheld, John C. Design and Layout of Foodservice Facilities (NewYork: Van Nostrand Reinhold, 1988) http://www.ciachef.edu http://www.iceculinary.com http://www.lecoleculinaire.com/ http://www.artinstitutes.edu/Phoenix http://www3.austin cc.edu http://www.archdaily.com/121226/institute-for-the-culinary-arts-hdr-architecture/ http://www.hdrinc.com/portfolio/institute-for-the-culinary-arts http://www.interiorsandsources.com/tabid/3339/ArticleID/12151/Default.aspx http://www.archdaily.com/100778/culinary-art-school-gracia-studio http://en.wikipedia.org/wiki/Cuisine http://www.freeusandworldmaps.com http://www.gustorganics.com/greenandorganic_ourquality.php http://www.uncommonground.com/ http://summerjos.com/pizza/ http://www.hydroponics.net/learn/hyrdoponic_gardening_for_beginners.asp http://home.howstuffworks.com/lawn-garden/professional-landscaping/alternative-methods/aeroponics.htm http:// www.livingmachines.com/about/how_it_works/ http:// www.garden-design-pictures.com/green-walls.html http:// www.reallynatural.com http:// www.greenroofs.com http://www.motherearthnews.com http:// www.greenlivingideas.com http://www.visitmississippi.org/poi-listing.aspx?city=&county=&cat=125&subcat=169 http://www.southernbbqtrail.com/map.shtml http://southernfoodways.org/documentary/oh/index.html http://www.prweb.com/releases/2011/3/prweb8185888.htm