caledonian military cables

Page 1

Caledonian Airframe Wire MIL-W-22759 MIL-W-81044


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS-British Standard;LPCB Fire Performance Standard. ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industry specific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.

2

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Military Specification Product Selection Guide Specification MIL-W-22759/1

MIL-W-22759/2

MIL-W-22759/3

MIL-W-22759/4 MIL-W-22759/5 MIL-W-22759/6 MIL-W-22759/7 MIL-W-22759/8 MIL-W-22759/9 MIL-W-22759/10 MIL-W-22759/11 MIL-W-22759/12 MIL-W-22759/13 MIL-W-22759/14 MIL-W-22759/15 MIL-W-22759/16 MIL-W-22759/17

Main Insulation Material Fluoropolymer insulated TFE and TFE coated glass Fluoropolymer insulated TFE and TFE coated glass Fluoropolymer insulated TFE and TFE coated glass Fluoropolymer insulated TFE and TFE coated glass 0.0255-0.036 Extruded PTFE Mineral Filled 0.0255-0.036 Extruded PTFE Mineral Filled 0.019-0.025 Extruded PTFE Mineral Filled 0.019-0.025 Extruded PTFE Mineral Filled 0.015 Extruded PTFE 0.015 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.011 Extruded FEP 0.008 Extruded FEP 0.008 Extruded FEP 0.010 Extruded ETFE 0.010 Extruded ETFE

Voltage Rating

Conductor Type

Temp Rating 째C

AWG Size

MILDTL27500 Symbol

600

SPC

200

22-0000

EA

600

NPC

260

22-0000

E

600

SPC

260

22-00

RA

600

NPC

200

22-00

RB

600

SPC

200

24-4

VA

600

NPC

260

24-4

WA

600

SPC

200

24-4

SA

600

NPC

260

24-6

TA

1000

SPC

200

28-8

LE

1000

NPC

260

28-8

LH

600

SPC

200

28-8

RC

/86

600

NPC

260

28-8

RE

/87

600

TPC

135

24-0

CA

/88

600

TPC

135

26-12

CB

/88

600

SP Alloy

135

26-10

CC

/89

600

TPC

150

24-00

TE

/88

600

SP Alloy

150

26-20

TF

/89

www.caledonian-cables.co.uk

www.addison-cables.com

MIL Composite Equivalent

3


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Specification MIL-W-22759/18 MIL-W-22759/19 MIL-W-22759/20 MIL-W-22759/21 MIL-W-22759/22 MIL-W-22759/23 MIL-W-22759/24 MIL-W-22759/25 MIL-W-22759/26 MIL-W-22759/27 MIL-W-22759/32 MIL-W-22759/33 MIL-W-22759/34 MIL-W-22759/35 MIL-W-22759/41 MIL-W-22759/42 MIL-W-22759/43 MIL-W-22759/44 MIL-W-22759/45 MIL-W-22759/46

4

Main Insulation Material 0.006 Extruded ETFE 0.006 Extruded ETFE 0.015 Extruded ETFE 0.015 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.010 Extruded PTFE 0.006 XLETFE Single Layer 0.006 XLETFE Single Layer 0.010 XLETFE Dual Layer 0.010 XLETFE Dual Layer 0.010 XLETFE Dual Layer 0.010 XLETFE Dual Layer 0.010 XLETFE Dual Layer 0.006 XLETFE Single Layer 0.006 XLETFE Single Layer 0.006 XLETFE Single Layer

Voltage Rating

Conductor Type

Temp Rating 째C

AWG Size

MILDTL27500 Symbol

MIL Composite Equivalent

600

TPC

150

26-10

TG

/80

600

SP Alloy

150

26-20

TH

/81

1000

SP Alloy

200

28-20

TK

1000

SP Alloy

260

28-20

TL

600

SP Alloy

200

28-20

TM

/89

600

SP Alloy

260

28-20

TN

/90

600

SPC

260

28-20

JB

/86

600

NPC

260

28-20

JC

/87

600

SP Alloy

200

28-20

JD

/89

600

SP Alloy

260

28-20

JE

/90

600

TPC

150

30-12

SB

/80

600

SP Alloy

200

30-20

SC

/81

600

TPC

150

24-00

SD

/88

600

SP Alloy

200

26-20

SE

/89

600

NPC

200

26-00

SM

/87

600

SP Alloy

200

26-20

SN

/90

600

SPC

200

28-00

SP

/86

600

SPC

200

28-12

SR

/91

600

NPC

200

28-12

SS

/92

600

NP Alloy

200

28-20

ST

/82

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Specification MIL-W-22759/80 MIL-W-22759/81 MIL-W-22759/82 MIL-W-22759/83 MIL-W-22759/84 MIL-W-22759/85 MIL-W-22759/86 MIL-W-22759/87 MIL-W-22759/88 MIL-W-22759/89 MIL-W-22759/90 MIL-W-22759/91 MIL-W-22759/92 MIL-W-81044/5 MIL-W-81044/6 MIL-W-81044/7 MIL-W-81044/8 MIL-W-81044/9 MIL-W-81044/10 MIL-W-81044/11 MIL-W-81044/12 MIL-W-81044/13

Main Insulation Material Light Weight Composite Light Weight Composite Light Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Normal Weight Composite Light Weight Composite Light Weight Composite Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene Extruded Xl Polyalkene

Voltage Rating

Conductor Type

Temp Rating 째C

AWG Size

MILDTL27500 Symbol

600

TPC

150

26-20

WB

600

SP Alloy

200

26-20

WC

600

NP Alloy

260

26-20

WE

600

SPC

200

02-0000

WF

600

NPC

260

02-0000

WG

600

TPC

150

02-0000

WH

600

SPC

200

26-0000

WJ

600

NPC

260

26-0000

WK

600

TPC

150

26-0000

WL

600

SP Alloy

200

26-20

WM

600

NP Alloy

260

26-20

WN

600

SPC

200

WP

600

NPC

260

WR

600

SPC

150

24-0

MD

600

TPC

150

24-0

ME

600

SP Alloy

150

26-20

MF

600

SPC

150

24-0

MG

600

TPC

150

24-0

MH

600

SP Alloy

150

26-20

MJ

600

SPC

150

30-12

MK

600

TPC

150

30-12

ML

600

SP Alloy

150

30-20

MM

MIL Composite Equivalent

SPC: Silver plated copper; NPC: Nickel Plated Copper; TPC: Tin Plated Copperl; SP Alloy: Silver Plated, High Strength Copper Alloy, Conductor; NP Alloy: Nickel Plated, High Strength Copper Alloy Conductor NP

www.caledonian-cables.co.uk

www.addison-cables.com

5


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables M27500 Basic Wire Specifications Cable Designation M27500 – 22 RC 2 S 06 M27500 : Specification number “-” : Shied coverage and color coding 22 : Conductor size RC : Component wire type 2 : Number of component wires S : Shield code 06 : Jacket code

Shied coverage and color coding (Color coding for M27500 cables is specified in conjunction with desired shiels coverage) M27500 Color code for Shield Coverage of Component wire identification method terminology

6

85%

90%

“-”

C

F

H

A

D

G

J

B

E

Optional method B, Table IIIC

K

M

Optional method C

L

N

Optional method D

www.caledonian-cables.co.uk

Preferred method , Table IIIA Preferred method, Table IIIB Optional method A, Table IIIA Optional method A, Table IIIB

White wires with colored stripes stripe color per Table IIIA White wires with colored stripes stripe color per Table IIIB Solid color wires - colors per Table IIIA Solid color wires - colors per Table IIIB Wires are all the same color (based on AWG size), per Table IIIC. Bands of a contrasting color are printed on each wire to denote wire number (circuit ID) per Table IIID. Wires are all the same color (based on AWG size), per Table IIIC. Numbers in a contrasting color are printed on each wire to denote wire number (circuit ID). White wires with numbers in a contrasting color printed on each wire to denote wire number (circuit ID).

www.addison-cables.com


Blue

White

Orange

3

Green

4

Red

5 Black

6 Yellow

7 Violet

8 Gray

9 Brown

10

12 Orange/ Orange

11 Blue/ Blue

Green/ Green

13

www.caledonian-cables.co.uk

2

Blue

1

Red

Yellow

3

Green

4

White

5 Black

6 Brown

7 Orange

8 Violet

9

Wire Number

●For either method the color of the wire in a one-conductor cable is white.

Gray

10

12 Blue/ White

11 Red/ White

Yellow/ White

13

● For “preferred method” color coding, colors are stripes on white inculation (wire #5 has no stripe), for wires 1-10. For wires 11-15, color pairs indicate insulation of the first color, with a stripe of the second color. ● For “optional method A” color coding, colors are solid insulation color, for wires 1-10. For wires 11-15, color pairs indicate insulation of the first color, with a stripe of the second color.

Table IIIB color coding

2

1

Wire Number

Green/ Whiter

14

Red/ Red

14

15

Black/ White

15

Black/ Black

● For “optional method A” color coding, colors are solid insulation color. Wires 11-15 have a stripe in a lighter shade of the base color.

● For “preferred method” color coding, color are stripes on white insulation (wire #1 has no stripe). Wires 11-15 have double stripes as indicated.

Table IIIA color coding

Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables

www.addison-cables.com

7


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Table IIIC color coding

● For "optional method B" color coding, wire insulation color is based on AWG size, with color bands per Table IIID to indicate wire number (circuit ID). ● For "optional method C" color coding, wire insulation color is based on AWG size, with numbers printed on each wire to indicate wire number (circuit ID).

AWG Size

Color

AWG Size

Color

26

Black

10

Brown

24

Blue

8

Red

22

Green

6

Blue

20

Red

4

Yellow

18

White

2

Red

16

Blue

1

White

14

Green

0

Blue

12

Yellow

1/0

Green

Table IIID Color Band Configuration ● For "optional method B" color coding, band groups as shown below are printed on wires to indicate wire number (circuit ID). Wire Wire Band configuration Band Configuration Number Number 1

None

9

1 wide, 2 narrow

■■■■

2

2 narrow

■■

10

1 wide, 3 narrow

■■■■■

3

3 narrow

■■■

11

1 wide, 4 narrow

■■■■■■

4

4 narrow

■■■■

12

1 wide, 5 narrow

■■■■■■■

5

5 narrow

■■■■■

13

1 wide, 1 narrow

■■■■■

6

6 narrow

■■■■■■

14

1 wide, 2 narrow

■■■■■■

7

7 narrow

■■■■■■■

15

1 wide, 3 narrow

■■■■■■■

8

1 wide, 1 narrow

8

■■■

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Component wire type Symbol sequence

Symbol sequence

CA

MIL-W-22759/13

SC

MIL-W-22759/33

CB

MIL-W-22759/14

SD

MIL-W-22759/34

CC

MIL-W-22759/15

SE

MIL-W-22759/35

E

MIL-W-22759/2

SM

MIL-W-22759/41

EA

MIL-W-22759/1

SN

MIL-W-22759/42

JB

MIL-W-22759/28

SP

MIL-W-22759/43

JC

MIL-W-22759/29

SR

MIL-W-22759/44

JD

MIL-W-22759/30

SS

MIL-W-22759/45

JE

MIL-W-22759/31

ST

MIL-W-22759/46

LE

MIL-W-22759/9

TA

MIL-W-22759/8

LH

MIL-W-22759/10

TE

MIL-W-22759/16

RA

MIL-W-22759/3

TF

MIL-W-22759/17

RB

MIL-W-22759/4

TG

MIL-W-22759/18

RC

MIL-W-22759/11

TH

MIL-W-22759/19

RE

MIL-W-22759/12

TK

MIL-W-22759/20

SA

MIL-W-22759/7

TL

MIL-W-22759/21

SB

MIL-W-22759/32

TM

MIL-W-22759/22

MD

MIL-W-81044/5

TN

MIL-W-22759/23

ME

MIL-W-81044/6

VA

MIL-W-22759/5

MF

MIL-W-81044/7

WA

MIL-W-22759/6

MG

MIL-W-81044/8

WB

MIL-W-22759/80

MH

MIL-W-81044/9

WC

MIL-W-22759/81

MJ

MIL-W-81044/10

WE

MIL-W-22759/82

MK

MIL-W-81044/11

WF

MIL-W-22759/83

ML

MIL-W-81044/12

WG

MIL-W-22759/84

MM

MIL-W-81044/13

WH

MIL-W-22759/85

WM

MIL-W-22759/89

WJ

MIL-W-22759/86

WN

MIL-W-22759/90

WK

MIL-W-22759/87

WP

MIL-W-22759/91

WL

MIL-W-22759/88

WR

MIL-W-22759/92

www.caledonian-cables.co.uk

www.addison-cables.com

9


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Number of component wires 1 to 15 for shielded or shielded and jacketed cables 2 to 15 for unshield, unjacketed or unshielded jacket cables Cables with 10 to 15 conductors will be limited to conductor size 12 and smaller

Shield code (When both double shield and double jacket are specified, the inner jacket is between the two layers of shield.) Letter Code Maximum temperature limit for shield materal Single Double Description ℃ ℉ Shield Shield U

No Shield

N/A

N/A

T

V

Round, tin-coated copper

150

302

S

W

Round, silver-coated copper

200

392

N

Y

Round, nickel-coated copper

160

500

F

Z

Round, stainless steel

400

752

C

R

M

K

P

L

G

Round, heavy nickel-coated copper Round, silver-coated high strength copper alloy Round, nickel-coated high strength copper alloy

400

752

200

392

260

500

A

Flat, silver-coated copper

200

392

H

B

Flat, silver-coated high strength copper alloy

200

392

*

#

Flat, nickel-coated copper

260

500

J

D

Flat, tin-coated copper

150

302

E

X

Flat, nickel-coated high strength copper alloy

260

500

I

Q

Flat, nickel-chromium alloy

400

752

10

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Jacket Code (Descriptions include jacket material and color) Jacket Code Single Jacket

Double Jacket

00

00

01

Temperature limit for jactet material

Description

℃

℉

No Jacket

N/A

N/A

511

Extruded white polyvinylchloride (PVC)

90

194

022

522

Extruded clear polyamide in accordance with ASTM-D-4066

105

221

03

53

105

221

04

54

150

302

05

55

200

392

06

56

260

500

07

57

260

500

083

583

Cross-linked white extruded polyvinylidene fluoride (PVDF)

150

302

09

59

Extruded white fluorinated ethylene propylene (FEP)

200

392

103

603

Extruded clear polyvinylidene fluoride (PVDF)

125

257

11*

61*

200

392

12*

62*

200

392

14

64

Extruded white ethylene-tetrafluoroethylene copolymer (ETFE)

150

302

15

65

Extruded clear ethylene-tetrafluoroethylene copolymer (ETFE)

150

302

16

66

Braid of aromatic polyamide with high temperature finisher over presintered polytetraflouroethylene (PTFE) tape

200

392

17a

67 a

Extruded white ethylene chlorotrifluoroethylene (ECTFE)

150

302

18 a

68 a

Exturded clear ethylene chlorotrifluoroethylene (ECTFE)

150

302

White Polyamide braid impregnated with clear polyamide finisher over polyester tape Polyester braid impregnated with high temperature finishers over polyester tape Extruded clear fluorinated ethylene propylene (FEP) Extruded or taped and heat sealed white polytetrafluoroethylene (PTFE) White polytetrafluoroethylene (PTFE) treated glass braid imprgnated and coated with polytetrafluoroethylene finisher over presintered polytetrafluoroethylene tape

Tape of natural polyimide combined with clear fluorinated ethylene propylene (FEP) wrapped and heat sealed witf (FEP) outer surface Tape of natural polyimide combined with fluorinated ethylene propylene (FEP) wrapped and heat sealed with polyimide outer surface

www.caledonian-cables.co.uk

www.addison-cables.com

11


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Jacket Code (Descriptions include jacket material and color) Jacket Code Single Jacket

Double Jacket

20

70

21

71

22

72

23

73

24

74

Description

Temperature limit for jactet material ℃

Extruded white perfluoroalkoxy (PFA)

260

500

Extruded clear perfluoroalkoxy (PFA)

260

500

260

392

200

392

200

392

Tape of polyimide combined with clear fluorinated ethylene propylene (FEP) wrapped and heat sealed with opaque polyimide outer surface Extruded white cross-linked modified ethylene-tetrafluoroethylene copolymer (XLETFE Tape layer of white polytetrafluoroethylene (PTFE) wrapped over a tape layer of natural polyimide combined with FEP and heat sealed

¹ Polyvinylchloride (PVC) materials shall not be used for Aerospace applications ² Jacket material 02/52 is not to be used for cables having a diameter of 0.251” (6.38mm) or greater ³ Jacket materials 08, 10, 58, and 60 are not to be used for cables having a diameter of 0.401” (10.19mm) or greater * Not for Naval Air Systems Command usage ª Inactive for new design

12

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-STD-681 Color Code Designators for Wire Designator

Base Color

0

BLK

1

BRN

2

RED

3

ORN

4

YEL

5

GRN

6

BLU

7

VIO

8

GRY

9

WHT

90

WHT

BLK

91

WHT

BRN

92

WHT

RED

93

WHT

ORN

94

WHT

YEL

95

WHT

GRN

96

WHT

BLU

97

WHT

VIO

98

WHT

GRY

901

WHT

BLK

BRN

902

WHT

BLK

RED

903

WHT

BLK

ORN

904

WHT

BLK

YEL

905

WHT

BLK

GRN

906

WHT

BLK

BLU

907

WHT

BLK

VIO

908

WHT

BLK

GRY

www.caledonian-cables.co.uk

1st Stripe

www.addison-cables.com

2nd Stripe

13


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables

14

Designator

Base Color

1st Stripe

2nd Stripe

912

WHT

BRN

RED

913

WHT

BRN

ORN

914

WHT

BRN

YEL

915

WHT

BRN

GRN

916

WHT

BRN

BLU

917

WHT

BRN

VIO

918

WHT

BRN

GRY

923

WHT

RED

ORN

924

WHT

RED

YEL

925

WHT

RED

GRN

926

WHT

RED

BLU

927

WHT

RED

VIO

928

WHT

RED

GRY

934

WHT

ORN

YEL

935

WHT

ORN

GRN

936

WHT

ORN

BLU

937

WHT

ORN

VIO

938

WHT

ORN

GRY

945

WHT

YEL

GRN

946

WHT

YEL

BLU

947

WHT

YEL

VIO

948

WHT

YEL

GRY

956

WHT

GRN

BLU

957

WHT

GRN

VIO

958

WHT

GRN

GRY

967

WHT

BLU

VIO

968

WHT

BLU

GRY

978

WHT

VIO

GRY

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Designator

Base Color

1st Stripe

2nd Stripe

3nd Stripe

9012

WHT

BLK

BRN

RED

9013

WHT

BLK

BRN

ORN

9014

WHT

BLK

BRN

YEL

9015

WHT

BLK

BRN

GRN

9016

WHT

BLK

BRN

BLU

9017

WHT

BLK

BRN

VIO

9018

WHT

BLK

BRN

GRY

9026

WHT

BLK

RED

ORN

9024

WHT

BLK

RED

YEL

9025

WHT

BLK

RED

GRN

9026

WHT

BLK

RED

BLU

9027

WHT

BLK

RED

VIO

9028

WHT

BLK

RED

GRY

9034

WHT

BLK

ORN

YEL

9035

WHT

BLK

ORN

GRN

9036

WHT

BLK

ORN

BLU

9037

WHT

BLK

ORN

VIO

9038

WHT

BLK

ORN

GRY

9045

WHT

BLK

YEL

GRN

9046

WHT

BLK

YEL

BLU

9047

WHT

BLK

YEL

VIO

9048

WHT

BLK

YEL

GRY

9056

WHT

BLK

GRN

BLU

9057

WHT

BLK

GRN

VIO

9058

WHT

BLK

GRN

GRY

9067

WHT

BLK

BLU

VIO

9068

WHT

BLK

BLU

GRY

9078

WHT

BLK

VIO

GRY

9123

WHT

BRN

RED

ORN

9124

WHT

BRN

RED

YEL

9125

WHT

BRN

RED

GRN

9126

WHT

BRN

RED

BLU

9127

WHT

BRN

RED

VIO

www.caledonian-cables.co.uk

www.addison-cables.com

15


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Designator

Base Color

1st Stripe

2nd Stripe

3nd Stripe

9128

WHT

BRN

RED

GRY

9134

WHT

BRN

ORN

YEL

9135

WHT

BRN

ORN

GEN

9136

WHT

BRN

ORN

BLU

9137

WHT

BRN

ORN

VIO

9138

WHT

BRN

ORN

GRY

9145

WHT

BRN

YEL

GRN

9146

WHT

BRN

YEL

BLU

9147

WHT

BRN

YEL

VIO

9148

WHT

BRN

YEL

GRY

9156

WHT

BRN

GRN

BLU

9157

WHT

BRN

GRN

VIO

16

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Table of content MIL-W-22759/1...................................................................................................................19 MIL-W-22759/2...................................................................................................................20 MIL-W-22759/3...................................................................................................................21 MIL-W-22759/4...................................................................................................................22 MIL-W-22759/5...................................................................................................................23 MIL-W-22759/6...................................................................................................................24 MIL-W-22759/7...................................................................................................................25 MIL-W-22759/8...................................................................................................................26 MIL-W-22759/9...................................................................................................................27 MIL-W-22759/10.................................................................................................................28 MIL-W-22759/11.................................................................................................................29 MIL-W-22759/12.................................................................................................................30 MIL-W-22759/13.................................................................................................................31 MIL-W-22759/14.................................................................................................................32 MIL-W-22759/15.................................................................................................................33 MIL-W-22759/16.................................................................................................................34 MIL-W-22759/17.................................................................................................................35 MIL-W-22759/18.................................................................................................................36 MIL-W-22759/19.................................................................................................................37 MIL-W-22759/20.................................................................................................................38 MIL-W-22759/21.................................................................................................................39 MIL-W-22759/22.................................................................................................................40 MIL-W-22759/23.................................................................................................................41 MIL-W-22759/28.................................................................................................................42 MIL-W-22759/29.................................................................................................................44 MIL-W-22759/30.................................................................................................................45 MIL-W-22759/31.................................................................................................................46 MIL-W-22759/32.................................................................................................................47 MIL-W-22759/33.................................................................................................................48

www.caledonian-cables.co.uk

www.addison-cables.com

17


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/34.................................................................................................................49 MIL-W-22759/35.................................................................................................................51 MIL-W-22759/41.................................................................................................................52 MIL-W-22759/42.................................................................................................................54 MIL-W-22759/43.................................................................................................................55 MIL-W-22759/44.................................................................................................................57 MIL-W-22759/45.................................................................................................................58 MIL-W-22759/46.................................................................................................................59 MIL-W-22759/80.................................................................................................................60 MIL-W-22759/81.................................................................................................................61 MIL-W-22759/82.................................................................................................................62 MIL-W-22759/83.................................................................................................................63 MIL-W-22759/84.................................................................................................................64 MIL-W-22759/85.................................................................................................................65 MIL-W-22759/86.................................................................................................................66 MIL-W-22759/87.................................................................................................................68 MIL-W-22759/88.................................................................................................................70 MIL-W-22759/89.................................................................................................................72 MIL-W-22759/90.................................................................................................................73 MIL-W-22759/91.................................................................................................................74 MIL-W-22759/92.................................................................................................................75 MIL-W-81044/5...................................................................................................................76 MIL-W-81044/6...................................................................................................................78 MIL-W-81044/7...................................................................................................................80 MIL-W-81044/8...................................................................................................................81 MIL-W-81044/9...................................................................................................................83 MIL-W-81044/10.................................................................................................................85 MIL-W-81044/11.................................................................................................................86 MIL-W-81044/12.................................................................................................................88 MIL-W-81044/13.................................................................................................................90

18

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/1 Application and Description These PTFE, FEP, and Glass insulated single-core MIL-W-22759/1 wires are used for MIL-Spec and Aerospace, government applications in which wire must operate in extremely harsh environments. These wires are abrasion resistant, withstanding vibration and exposure to open flame.

Construction Details The first layer is PTFE wrapped tape. The second and third layers are PTFE coated glass braid.

Construction Conductor: Silver-plated copper Insulation: PTFE, FEP, and Glass Insulating Material Thickness: 54 mil ( 1.4 mm) to 125 mil ( 3.2mm)

Characteristics Glass insulation

Temperature Rating: 200째C

FEP insulation Silver-plated copper conductor

Voltage Rating: 600 volts SAE AS22759/1

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size 22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0

Conductor Stranding 19/34 19/32 19/30 19/29 19/27 37/28 37/16 133/29 133/27 133/25 665/30 817/30 1045/30 1330/30 1665/30 2109/30

Conductor Diam. Min in mm 0.029 0.737 0.037 0.940 0.046 1.168 0.052 1.321 0.065 1.651 0.084 2.134 0.406 10.312 0.158 4.013 0.198 5.029 0.250 6.350 0.320 8.128 0.360 9.144 0.395 10.033 0.440 11.176 0.500 12.70 0.565 14.351

Conductor Diam. Max in mm 0.032 0.813 0.040 1.016 0.050 1.270 0.057 1.448 0.072 1.829 0.089 2.261 0.112 2.845 0.169 4.293 0.213 5.410 0.268 6.807 0.340 8.636 0.380 9.652 0.425 10.795 0.475 12.065 0.540 13.716 0.605 15.367

www.caledonian-cables.co.uk

Min O.D. in 0.08 0.09 0.100 0.115 0.133 0.152 0.174 0.241 0.283 0.400 0.405 0.455 0.495 0.555 0.620 0.69

mm 2.032 2.286 2.540 2.921 3.378 3.861 4.420 6.121 7.188 10.160 10.287 11.557 12.573 14.097 15.748 17.526

Max O.D. in 0.088 0.098 0.110 0.125 0.143 0.162 0.188 0.255 0.303 0.43 0.435 0.485 0.535 0.595 0.660 0.730

mm 2.235 2.489 2.794 3.175 3.632 4.115 4.775 6.477 7.696 10.922 11.049 12.319 13.589 15.113 16.764 18.542

www.addison-cables.com

Approx LBS/ MFT 7.5 9.5 13.0 16.5 23.0 32.1 47 82 122 180 275 348 429 542 668 835

19


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/2 Application and Description These PTFE, FEP, and Glass insulated single-core MIL-W-22759/2 wires are used for MIL-Spec and Aerospace, government applications in which wire must operate in extremely harsh environments. These wires are abrasion resistant, withstanding vibration and exposure to open flame.

Construction Details The first layer is PTFE wrapped tape. The second and third layers are PTFE coated glass braid.

Construction Conductor: Nickel plated copper Insulation: PTFE, FEP, and Glass Insulating Material Thickness: 54 mil ( 1.4 mm) to 125 mil ( 3.2mm)

Characteristics Temperature Rating: 260°C

Glass insulation

 Voltage Rating: 600 volts

FEP insulation Nickel plated copper conductor

SAE AS22759/2 Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight: AWG Size

Conductor Stranding

Conductor Diam. Min in mm 0.029 0.737 0.037 0.940 0.046 1.168 0.052 1.321 0.065 1.651 0.084 2.134 0.106 2.692 0.158 4.013 0.198 5.029 0.250 6.350 0.320 8.128 0.360 9.144 0.395 10.033 0.440 11.176 0.500 12.700 0.565 14.351

Conductor Diam. Max in mm 0.033 0.838 0.041 1.041 0.051 1.295 0.058 1.473 0.073 1.854 0.090 2.286 0.114 2.896 0.173 4.394 0.217 5.512 0.274 6.960 0.340 8.636 0.380 9.652 0.425 10.795 0.475 12.065 0.540 13.716 0.605 15.367

22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0

19/34 19/32 19/30 19/29 19/27 37/28 37/16 133/29 133/27 133/25 665/30 817/30 1045/30 1330/30 1665/30 2109/30

20

www.caledonian-cables.co.uk

Min O.D. in 7.5 9.5 13.0 16.5 23.0 32.1 47.0 82.0 122.0 180.0 275.0 348.0 429.0 542.0 668.0 835.0

mm 2.032 2.286 2.540 2.921 3.378 3.861 4.420 6.121 7.188 10.160 10.287 11.557 12.573 14.097 15.748 17.526

Max O.D. in 0.088 0.098 0.110 0.125 0.143 0.162 0.188 0.255 0.303 0.430 0.435 0.485 0.535 0.595 0.660 0.730

www.addison-cables.com

mm 2.235 2.489 2.794 3.175 3.632 4.115 4.775 6.477 7.696 10.922 11.049 12.319 13.589 15.113 16.764 18.542

Approx LBS/ MFT 7.5 9.5 13.0 16.5 23.0 32.1 47.0 82.0 122.0 180.0 275.0 348.0 429.0 542.0 668.0 835.0


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/3 Application and Description These PTFE, FEP, and Glass insulated single-core MIL-W-22759/3 wires are used for MIL-Spec and Aerospace, government applications. These wires are used in aircraft engines and abrasion environment.

Construction Details The first layer is PTFE either as a wrapped tape or PTFE coated glass tape. The second layer is PTFE coated glass braid and finisher. The jacket FEP is either extruded or on larger wire sizes a tape; the FEP has to be fused.

Construction Conductor: Nickel plated copper Insulation: PTFE, FEP, and Glass Insulating Material Thickness: 40 mil ( 1.0 mm) to 125 mil ( 3.2mm)

Characteristics Temperature Rating: 260째C

Glass insulation

Voltage Rating: 600 volts SAE AS22759/3

FEP insulation Nickel plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight AWG Size

Conductor Stranding

22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0

19/34 19/32 19/30 19/29 19/27 37/28 37/16 133/29 133/27 133/25 665/30 817/30 1045/30 1330/30

Conductor Diam. Min in mm 0.029 0.737 0.037 0.940 0.046 1.168 0.052 1.321 0.065 1.651 0.084 2.134 0.106 2.692 0.158 4.013 0.198 5.029 0.250 6.350 0.320 8.128 0.360 9.144 0.395 10.033 0.440 11.176

Conductor Diam. Max in 0.033 0.041 0.051 0.058 0.073 0.090 0.114 0.173 0.217 0.274 0.340 0.380 0.425 0.475

mm 0.838 1.041 1.295 1.473 1.854 2.286 2.896 4.394 5.512 6.960 8.636 9.652 10.795 12.065

www.caledonian-cables.co.uk

Min O.D. in 0.08 0.09 0.10 0.115 0.133 0.152 0.174 0.241 0.283 0.40 0.405 0.455 0.495 0.555

mm 2.032 2.286 2.540 2.921 3.378 3.861 4.420 6.121 7.188 10.16 10.287 11.557 12.573 14.097

Max O.D. in 0.088 0.098 0.110 0.125 0.143 0.162 0.188 0.255 0.303 0.430 0.435 0.485 0.535 0.595

mm 2.235 2.489 2.794 3.175 3.632 4.115 4.775 6.477 7.696 10.922 11.049 12.319 13.589 15.113

www.addison-cables.com

Approx LBS/ MFT 5.9 7.9 11.0 13.6 18.5 26.6 41.5 77.4 115.0 184.0 281.0 358.0 436.0 554.0

21


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/4 Application and Description These PTFE, FEP, and Glass insulated single-core MIL-W-22759/4 wires are used for MIL-Spec and Aerospace, government applications. These wires are used in aircraft engines and abrasion environment.

Construction Details The first layer is PTFE either as a wrapped tape or PTFE coated glass tape. The second layer is PTFE coated glass braid and finisher. The jacket FEP is either extruded or on larger wire sizes a tape; the FEP has to be fused.

Construction Conductor: Silver plated copper Insulation: PTFE, FEP, and Glass Insulating Material Thickness: 25 mil ( 0.6 mm) to 44 mil ( 1.1mm)

Characteristics Temperature Rating: 200째C

Glass insulation

Voltage Rating: 600 volts SAE AS22759/4

FEP insulation Silver plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight Conductor Diam. Min

Conductor Diam. Max in mm 0.030 0.772 0.039 0.975 0.048 1.229 0.054 1.382 0.068 1.737 0.087 2.220 0.110 2.794 0.166 4.216 0.208 5.283 0.263 6.680 0.340 8.636 0.380 9.652 0.425 10.795 0.475 12.065

AWG Size

Conductor Stranding

22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0

19/34 19/32 19/30 19/29 19/27 37/28 37/26 133/29 133/27 133/25 665/30 817/30 1045/30 1330/30

22

www.caledonian-cables.co.uk

in 0.029 0.037 0.046 0.052 0.065 0.084 0.106 0.158 0.198 0.250 0.320 0.366 0.395 0.440

mm 0.724 0.927 1.156 1.308 1.638 2.121 2.692 4.013 5.029 6.350 8.128 9.296 10.033 11.176

Min O.D. in 0.071 0.079 0.092 0.990 0.112 0.129 0.159 0.228 0.272 0.336 0.415 0.465 0.500 0.560

mm 1.803 2.007 2.337 25.146 2.845 3.277 4.039 5.791 6.909 8.534 10.541 11.811 12.700 14.224

Max O.D. in 0.077 0.085 0.098 0.998 0.120 0.137 0.171 0.242 0.292 0.366 0.445 0.495 0.550 0.610

www.addison-cables.com

mm 1.956 2.159 2.489 25.349 3.048 3.48 4.343 6.147 7.417 9.296 11.303 12.573 13.97 15.494

Approx LBS/ MFT 5.9 7.9 11.0 13.6 18.5 26.6 41.5 77.4 115.0 184.0 281.0 358.0 436.0 554.0


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/5 Application and Description These PTFE insulated single-core MIL-W-22759/5 wires are used for MIL-Spec and Aerospace, government applications or aircraft engines, and where extra abrasion resistance and good flexibility are required.

Construction Details PTFE is extruded

Construction Conductor: Silver plated copper Insulation: Mineral filled PTFE Teflon Insulating Material Thickness: 25 mil ( 0.6 mm) to 44 mil ( 1.1mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 600 volts SAE AS22759/5

Silver plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Conductor Diam. Min Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

24

19/36

0.023

0.584

0.025

0.635

6.0

1.778

0.08

2.032

6.0

22

19/34

0.029

0.737

0.031

0.772

8.0

2.032

0.09

2.286

8.0

20

19/32

0.037

0.940

0.038

0.975

10.0

2.286

0.10

2.540

10.0

18

19/30

0.046

1.156

0.048

1.229

12.9

2.667

0.12

2.921

12.9

16

19/29

0.052

1.308

0.054

1.382

16.6

3.048

0.13

3.302

16.6

14

19/27

0.065

1.638

0.068

1.737

22.5

3.454

0.15

3.810

22.5

12

19/25

0.084

2.121

0.087

2.220

30.9

3.886

0.17

4.242

30.9

10

37/26

0.106

2.692

0.110

2.794

42.5

4.369

0.183

4.648

42.5

8

133/29

0.158

4.013

0.166

4.216

77.0

6.121

0.255

6.477

77.0

6

133/27

0.198

5.029

0.208

5.283

126.0

7.366

0.310

7.874

126.0

4

133/25

0.250

6.350

0.263

6.680

188.0

8.636

0.370

9.398

188.0

www.caledonian-cables.co.uk

www.addison-cables.com

23


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/6 Application and Description These PTFE insulated single-core MIL-W-22759/6 wires are used for MIL-Spec and Aerospace, government applications or aircraft engines, and where extra abrasion resistance and good flexibility are required.

Construction Details PTFE is extruded

Construction Conductor: Nickel plated copper Insulation: Mineral filled PTFE Teflon Insulating Material Thickness:25 mil ( 0.6 mm) to 44 mil ( 1.1mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 600 volts SAE AS22759/6

Nickel plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Max in mm

Conductor Diam. Min in

mm

Min O.D.

Max O.D.

in

mm

In

mm

Approx LBS/ MFT

24

19/36

0.023

0.584

0.026

0.660

0.070

1.78

0.08

2.03

6.0

22

19/34

0.029

0.737

0.031

0.787

0.080

2.03

0.09

2.29

8.0

20

19/32

0.037

0.940

0.039

0.991

0.090

2.29

0.10

2.54

10.0

18

19/30

0.046

1.168

0.049

1.245

0.105

2.67

0.12

2.92

13.1

16

19/29

0.052

1.321

0.053

1.346

0.120

3.05

0.13

3.30

16.9

14

19/27

0.065

1.651

0.069

1.753

0.136

3.45

0.15

3.81

23.3

12

19/25

0.084

2.134

0.089

2.261

0.153

3.89

0.17

4.24

31.9

10

37/26

0.106

2.692

0.112

2.845

0.172

4.37

0.19

4.73

43.5

8

133/29

0.158

4.013

0.169

4.293

0.241

6.12

0.26

6.48

79.0

6

133/27

0.198

5.029

0.213

5.410

0.283

7.19

0.30

7.70

127.0

4

133/29

0.250

6.350

0.268

6.807

0.400

10.16

0.43

10.92

190.0

24

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/7 Application and Description These PTFE insulated single-core MIL-W-22759/7 wires are used for MIL-Spec and Aerospace, government applications or aircraft engines, and where extra abrasion resistance and good flexibility are required.

Construction Details PTFE is extruded

Construction Conductor: Silver plated copper Insulation: Mineral filled PTFE Teflon Insulating Material Thickness: 14 mil ( 0.4 mm) to 36 mil ( 0.9mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 600 volts

Silver plated copper conductor

SAE AS22759/7

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

24

19/36

0.023

0.584

0.025

0.635

0.060

1.524

0.064

1.626

4.3

22

19/34

0.029

0.724

0.030

0.772

0.071

1.803

0.075

1.905

6.0

20

19/32

0.037

0.927

0.038

0.975

0.080

2.032

0.084

2.134

8.1

18

19/30

0.046

1.156

0.048

1.229

0.090

2.286

0.094

2.388

11.0

16

19/29

0.052

1.308

0.054

1.382

0.099

2.515

0.105

2.667

13.8

14

19/27

0.065

1.638

0.068

1.737

0.112

2.845

0.118

2.997

18.6

12

19/25

0.084

2.121

0.087

2.220

0.131

3.327

0.137

3.480

28.5

10

37/26

0.106

2.692

0.110

2.794

0.154

3.912

0.162

4.115

41.8

8

133/29

0.158

4.013

0.166

4.216

0.215

5.461

0.225

5.715

73.1

6

133/27

0.198

5.029

0.208

5.283

0.264

6.706

0.276

7.010

111.0

4

133/25

0.250

6.350

0.263

6.680

0.321

8.153

0.335

8.509

169.0

www.caledonian-cables.co.uk

www.addison-cables.com

25


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/8 Application and Description These PTFE insulated single-core MIL-W-22759/8 wires are used for MIL-Spec and Aerospace, government applications or aircraft engines, and where extra abrasion resistance and good flexibility are required.

Construction Details PTFE is extruded

Construction Conductor: Nickel plated copper Insulation: Mineral filled PTFE Teflon Insulating Material Thickness: 14 mil ( 0.4 mm) to 36 mil ( 0.9mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 600 volts

Nickel plated copper conductor

SAE AS22759/8

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Max in mm

Conductor Diam. Min in

mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/MFT

24

19/36

0.023

0.584

0.026

0.660

0.060

1.524

0.064

1.626

4.3

22

19/34

0.029

0.737

0.033

0.838

0.071

1.803

0.075

1.905

6.0

20

19/32

0.037

0.940

0.041

1.041

0.080

2.032

0.084

2.134

8.1

18

19/30

0.046

1.168

0.052

1.321

0.090

2.286

0.094

2.388

11.0

16

19/29

0.052

1.321

0.058

1.473

0.099

2.515

0.105

2.667

13.8

14

19/27

0.065

1.651

0.073

1.854

0.112

2.845

0.118

2.997

18.6

12

19/25

0.087

2.210

0.092

2.337

0.131

3.327

0.137

3.480

28.5

10

37/26

0.106

2.692

0.114

2.896

0.154

3.912

0.162

4.115

41.8

8

133/29

0.158

4.013

0.173

4.394

0.215

5.461

0.225

5.715

73.1

6

133/27

0.198

5.029

0.217

5.512

0.264

6.706

0.276

7.010

113.0

4

133/25

0.250

6.350

0.274

6.960

0.319

8.103

0.333

8.458

173.0

26

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/9 Application and Description These PTFE insulated single-core MIL-W-22759/9 wires are used for MIL-Spec and Aerospace applications or aircraft engines, These wires work especially well where smoke emission, overload stability, and flammability are major concerns.

Construction Details PTFE is extruded

Construction Conductor: Silver plated copper Insulation: Extruded PTFE Teflon Insulating Material Thickness: 14 mil ( 0.4 mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 1000 volts SAE AS22759/9

Silver plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight AWG Size

Conductor Conductor Diam. Stranding Min in

mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.015

0.381

0.041

1.041

0.045

1.143

1.9

26

19/36

0.018

0.457

0.020

0.508

0.046

1.168

0.05

1.270

2.6

24

19/38

0.025

0.635

0.025

0.635

0.051

1.295

0.055

1.397

3.3

22

19/34

0.029

0.724

0.030

0.772

0.058

1.473

0.062

1.575

4.6

20

19/32

0.037

0.927

0.038

0.975

0.066

1.676

0.070

1.778

6.4

18

19/30

0.046

1.156

0.048

1.229

0.076

1.930

0.080

2.032

9.1

16

19/29

0.0515

1.308

0.054

1.382

0.083

2.108

0.087

2.210

11.0

14

19/27

0.0645

1.638

0.068

1.737

0.097

2.464

0.103

2.616

16.4

12

19/25

0.0835

2.121

0.087

2.220

0.116

2.946

0.124

3.150

25.3

10

37/26

0.1060

2.692

0.110

2.794

0.137

3.480

0.145

3.683

38.2

8

133/29

0.1580

4.013

0.166

4.216

0.202

5.131

0.212

5.385

68.8

www.caledonian-cables.co.uk

www.addison-cables.com

27


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/10 Application and Description These PTFE insulated single-core MIL-W-22759/10 wires are used for MIL-Spec and Aerospace applications or aircraft engines, These wires work especially well where smoke emission, overload stability, and flammability are major concerns

Construction Details PTFE is extruded

Construction Conductor: Nickel plated copper Insulation: Extruded PTFE Teflon Insulating Material Thickness: 14 mil ( 0.4 mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 1000 volts

Nickel plated copper conductor

SAE AS22759/10

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.041

1.041

0.045

1.143

1.9

26

19/38

0.016

0.406

0.022

0.559

0.046

1.168

0.050

1.270

2.6

24

19/36

0.023

0.584

0.026

0.660

0.051

1.295

0.055

1.397

3.3

22

19/34

0.029

0.737

0.033

0.838

0.058

1.473

0.062

1.575

4.6

20

19/32

0.037

0.940

0.041

1.041

0.066

1.676

0.070

1.778

6.4

18

19/30

0.046

1.168

0.052

1.321

0.076

1.93

0.080

2.032

9.1

16

19/29

0.052

1.321

0.058

1.473

0.083

2.108

0.087

2.210

11.0

14

19/27

0.065

1.651

0.073

1.854

0.097

2.464

0.103

2.616

16.4

12

19/25

0.087

2.210

0.092

2.337

0.116

2.946

0.124

3.150

25.3

10

37/26

0.106

2.692

0.114

2.896

0.137

3.48

0.145

3.683

38.2

8

133/29

0.158

4.013

0.173

4.394

0.202

5.131

0.212

5.385

68.8

28

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/11 Application and Description These PTFE insulated single-core MIL-W-22759/11 wires are used for MIL-Spec and Aerospace. These wires are used in aircraft engines and wherever abrasion.

Construction Details PTFE is extruded

Construction Conductor: Silver plated copper Insulation: Extruded PTFE Teflon Insulating Material Thickness: 10 mil ( 0.25 mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 600 volts

Silver plated copper conductor

SAE AS22759/11

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in

mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.015

0.381

0.031

0.787

0.035

0.889

1.22

26

19/38

0.018

0.457

0.020

0.508

0.036

0.914

0.040

1.016

1.74

24

19/36

0.023

0.584

0.025

0.635

0.041

1.041

0.045

1.143

2.41

22

19/34

0.029

0.724

0.030

0.772

0.047

1.194

0.051

1.295

3.44

20

19/32

0.037

0.927

0.038

0.975

0.056

1.422

0.060

1.524

5.15

18

19/30

0.046

1.156

0.048

1.229

0.066

1.676

0.070

1.778

7.58

16

19/29

0.052

1.308

0.054

1.382

0.073

1.854

0.077

1.956

9.64

14

19/27

0.066

1.638

0.068

1.737

0.088

2.235

0.092

2.337

14.7

12

19/25

0.084

2.121

0.087

2.220

0.108

2.743

0.114

2.896

23.5

10

37/26

0.106

2.692

0.110

2.794

0.106

2.692

0.112

2.845

37.8

8

133/29

0.158

4.013

0.166

4.216

0.158

4.013

0.169

4.293

65.5

www.caledonian-cables.co.uk

www.addison-cables.com

29


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/12 Application and Description These PTFE insulated single-core MIL-W-22759/12 wires are used for MIL-Spec and Aerospace. These wires are used in aircraft engines and wherever abrasion.

Construction Details PTFE is extruded

Construction Conductor: Nickel plated copper Insulation: Extruded PTFE Teflon Insulating Material Thickness: 10 mil ( 0.25 mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 600 volts SAE AS22759/12

Nickel plated copper conductor

Color Code: MIL-STD-681

PTFE insulation

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.015

0.381

0.026

0.66

0.031

0.787

0.035

0.889

1.23

26

19/38

0.016

0.406

0.022

0.559

0.036

0.914

0.040

1.016

1.75

24

19/36

0.023

0.584

0.026

0.660

0.041

1.041

0.045

1.143

2.42

22

19/34

0.029

0.737

0.033

0.838

0.047

1.194

0.051

1.295

3.46

20

19/32

0.037

0.940

0.041

1.041

0.056

1.422

0.060

1.524

5.19

18

19/30

0.046

1.168

0.052

1.321

0.066

1.676

0.070

1.778

7.64

16

19/29

0.052

1.321

0.058

1.473

0.073

1.854

0.077

1.956

9.74

14

19/27

0.065

1.651

0.073

1.854

0.088

2.235

0.092

2.337

14.8

12

19/25

0.087

2.210

0.092

2.337

0.108

2.743

0.114

2.896

24.0

10

37/26

0.106

2.692

0.114

2.896

0.100

2.540

0.114

2.896

39.0

8

133/29

0.158

4.013

0.173

4.394

0.158

4.013

0.173

4.394

67.0

30

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/13 Application and Description These FEP insulated single-core MIL-W-22759/13 wires are used for MIL-Spec and Aerospace.

Construction Details FEP is extruded

Construction Conductor: Tin plated copper Insulation: Extruded FEP Jacket: Clear PVDF Insulating Material Thickness: 11 mil ( 0.30 mm)

Characteristics Temperature Rating: 135째C Voltage Rating: 600 volts SAE AS22759/13

PVDF jacket Tin plated copper conductor

Color Code: MIL-STD-681

FEP insulation

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

24

19/36

0.023

0.584

0.025

0.635

0.047

1.194

0.051

1.295

2.9

22

19/34

0.029

0.724

0.030

0.772

0.048

1.219

0.054

1.372

3.9

20

19/32

0.037

0.927

0.038

0.975

0.058

1.473

0.064

1.626

5.5

18

19/30

0.045

1.130

0.048

1.229

0.068

1.727

0.074

1.880

8.0

16

19/29

0.052

1.308

0.054

1.382

0.073

1.854

0.081

2.057

10.1

14

19/27

0.065

1.638

0.068

1.737

0.087

2.210

0.095

2.413

15.5

12

37/28

0.086

2.172

0.089

2.261

0.107

2.718

0.115

2.921

23.0

10

37/26

0.106

2.692

0.112

2.845

0.134

3.404

0.142

3.607

35.7

8

133/28

1.580

40.132

0.169

4.293

0.190

4.826

0.202

5.131

62.8

6

133/27

1.980

50.292

0.212

5.385

0.239

6.071

0.255

6.477

99.3

4

133/25

0.250

6.350

0.268

6.807

0.292

7.417

0.308

7.823

153.0

2

665/30

0.320

8.128

0.340

8.636

0.362

9.195

0.386

9.804

247.0

1

817/30

0.360

9.144

0.380

9.652

0.398

10.109

0.426

10.82

311.0

1/0

1045/30

0.405

10.287

0.425

10.795

0.442

11.227

0.474

12.04

387.0

www.caledonian-cables.co.uk

www.addison-cables.com

31


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/14 Application and Description These FEP insulated single-core MIL-W-22759/14 wires are used for MIL-Spec and Aerospace.

Construction Details FEP is extruded

Construction Conductor: Tin plated copper Insulation: Extruded FEP Jacket: Clear PVDF Insulating Material Thickness: 8 mil ( 0.2 mm)

Characteristics Temperature Rating: 135째C Voltage Rating: 600 volts SAE AS22759/14

PVDF jacket Tin plated copper conductor

Color Code: MIL-STD-681

FEP insulation

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

In

Mm

In

mm

(in)

mm

(in)

mm

Approx LBS/ MFT

26

19/38

0.018

0.457

0.020

0.508

0.035

0.889

0.039

0.991

1.8

24

19/36

0.023

0.584

0.024

0.610

0.040

1.016

0.044

1.118

2.47

22

19/34

0.029

0.724

0.031

0.787

0.045

1.143

0.051

1.295

3.53

20

19/32

0.037

0.927

0.039

0.991

0.053

1.346

0.059

1.499

5.13

18

19/30

0.046

1.156

0.049

1.245

0.063

1.600

0.069

1.753

7.64

16

19/29

0.052

1.308

0.055

1.397

0.067

1.702

0.075

1.905

9.34

14

19/27

0.065

1.638

0.069

1.753

0.083

2.108

0.091

2.311

14.4

12

37/28

0.084

2.134

0.089

2.261

0.103

2.616

0.111

2.819

22.3

32

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/15 Application and Description These FEP insulated single-core MIL-W-22759/15 wires are used for MIL-Spec and Aerospace.

Construction Details FEP is extruded

Construction

PVDF jacket Silver plated high-strength copper conductor FEP insulation

Conductor: Silver plated high-strength copper alloy Insulation: Extruded FEP Jacket: Clear PVDF Insulating Material Thickness: 11 mil ( 0.30 mm)

Characteristics Temperature Rating: 135째C Voltage Rating: 600 volts SAE AS22759/15 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.457

0.020

0.508

0.035

0.889

0.039

0.991

1.75

24

19/36

0.023

0.584

0.026

0.660

0.040

1.016

0.044

1.118

2.42

22

19/34

0.029

0.737

0.330

8.382

0.045

1.143

0.051

1.295

3.59

20

19/32

0.037

0.94

0.041

1.041

0.053

1.346

0.059

1.499

5.22

www.caledonian-cables.co.uk

www.addison-cables.com

33


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/16 Application and Description These ETFE insulated single-core MIL-W-22759/16 wires are used for MIL-Spec and Aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals.

Construction Details ETFE is extruded

Construction Conductor: Tin plated copper Insulation: Extruded ETFE Insulating Material Thickness: 10 mil ( 0.25 mm)

Characteristics Temperature Rating: 150째C Voltage Rating: 600 volts

Tin plated copper conductor

SAE AS22759/16

ETFE insulation

Color Code: MIL-STD-681

Dimensions and Weight Conductor Diam. Min

Conductor Diam. Max in mm 0.024 0.610 0.031 0.787 0.039 0.991 0.049 1.245 0.055 1.397 0.069 1.753 0.089 2.261 0.112 2.845 0.169 4.293 0.212 5.385 0.268 6.807 0.340 8.636 0.380 9.652 0.475 12.065 0.425 10.795

AWG Size

Conductor Stranding

24 22 20 18 16 14 12 10 8 6 4 2 1 2/0 1/0

19/36 19/34 19/32 19/30 19/29 19/27 37/28 37/26 133/29 133/27 133/25 665/30 817/30 1330/30 1045/30

34

www.caledonian-cables.co.uk

in 0.023 0.029 0.037 0.046 0.052 0.065 0.087 0.106 0.158 0.198 0.250 0.320 0.360 0.440 0.395

mm 0.584 0.737 0.940 1.168 1.321 1.651 2.210 2.692 4.013 5.029 6.350 8.128 9.144 11.176 10.033

Min O.D. in 0.043 0.050 0.058 0.069 0.077 0.091 0.111 0.136 0.196 0.247 0.308 0.384 0.426 0.539 0.473

mm 1.092 1.270 1.473 1.753 1.956 2.311 2.819 3.454 4.978 6.274 7.823 9.754 10.820 13.691 12.014

Max O.D. in 0.047 0.054 0.062 0.073 0.081 0.095 0.117 0.142 0.202 0.253 0.316 0.392 0.436 0.553 0.485

www.addison-cables.com

mm 1.194 1.372 1.575 1.854 2.057 2.413 2.972 3.607 5.131 6.426 8.026 9.957 11.074 14.046 12.319

Approx LBS/ MFT 2.4 3.52 5.18 7.65 9.68 14.5 21.8 34.0 61.5 96.9 152.0 231.0 314.0 504.0 391.0


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/17 Application and Description These ETFE insulated single-core MIL-W-22759/17 wires are used for MIL-Spec and Aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals.

Construction Details ETFE is extruded

Construction

Silver plated high-strength copper conductor ETFE insulation

Conductor: Silver plated high-strength copper alloy Insulation: Extruded ETFE Insulating Material Thickness: 10 mil ( 0.25 mm)

Characteristics Temperature Rating: 150째C Voltage Rating: 600 volts SAE AS22759/17 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.457

0.020

0.508

0.038

0.965

0.042

1.067

1.67

24

19/36

0.023

0.584

0.026

0.660

0.043

1.092

0.047

1.194

2.32

22

19/34

0.029

0.737

0.033

0.838

0.050

1.270

0.054

1.372

3.40

20

19/32

0.037

0.940

0.041

1.041

0.058

1.473

0.062

1.575

4.96

www.caledonian-cables.co.uk

www.addison-cables.com

35


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/18 Application and Description These ETFE insulated single-core MIL-W-22759/18 wires are used for MIL-Spec and Aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals.

Construction Details ETFE is extruded

Construction

Silver plated high-strength copper conductor ETFE insulation

Conductor: Tin plated copper Insulation: Extruded Thin Wall ETFE Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 150째C Voltage Rating: 600 volts SAE AS22759/18 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

26 24 22 20 18 16 14 12 10

19/38 19/36 19/34 19/32 19/30 19/29 19/27 37/28 37/26

36

Conductor Diam. Min in mm 0.180 4.572 0.023 0.584 0.029 0.737 0.037 0.940 0.046 1.168 0.052 1.321 0.065 1.651 0.087 2.210 0.106 2.692

Conductor Diam. Max in mm 0.020 0.508 0.024 0.610 0.031 0.787 0.039 0.991 0.049 1.245 0.055 1.397 0.069 1.753 0.089 2.261 0.112 2.845

www.caledonian-cables.co.uk

Min O.D. in 0.030 0.034 0.041 0.049 0.059 0.065 0.079 0.101 0.124

mm 0.762 0.864 1.041 1.245 1.499 1.651 2.007 2.565 3.150

Max O.D. in 0.034 0.038 0.045 0.053 0.063 0.069 0.083 0.105 0.128

www.addison-cables.com

mm 0.864 0.965 1.143 1.346 1.600 1.753 2.108 2.667 3.251

Approx LBS/ MFT 1.45 2.02 3.04 4.60 6.86 8.69 13.30 20.50 31.90


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/19 Application and Description These ETFE insulated single-core MIL-W-22759/19 wires are used for MIL-Spec and Aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals.

Construction Details ETFE is extruded

Construction

Silver plated high-strength copper conductor PTFE insulation

Conductor: Silver plated high-strength copper alloy Insulation: Extruded Thin Wall ETFE Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 150째C Voltage Rating: 600 volts SAE AS22759/19 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in

mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.445

0.020

0.518

0.030

0.762

0.034

0.864

1.4

24

19/36

0.023

0.572

0.024

0.620

0.034

0.864

0.038

0.965

1.9

22

19/34

0.029

0.724

0.031

0.798

0.041

1.041

0.045

1.143

2.9

20

19/32

0.037

0.927

0.040

1.003

0.049

1.245

0.053

1.346

4.6

www.caledonian-cables.co.uk

www.addison-cables.com

37


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/20 Application and Description These PTFE insulated single-core MIL-W-22759/20 wires are used for MIL-Spec and Aerospace, They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns.

Construction Details PTFE is extruded

Construction

Silver plated high-strength copper conductor PTFE insulation

Conductor: Silver plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 29 mil ( 0.70 mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 1000 volts SAE AS22759/20 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min In Mm

Conductor Diam. Max In mm

Min O.D.

Max O.D.

(in)

mm

(in)

mm

Approx LBS/ MFT

28

7/36

0.140

3.556

0.015

0.381

0.041

1.041

0.045

1.143

1.91

26

19/38

0.018

0.445

0.020

0.518

0.046

1.168

0.05

1.270

2.57

24

19/36

0.023

0.572

0.024

0.620

0.051

1.295

0.055

1.397

3.35

22

19/34

0.029

0.724

0.031

0.798

0.058

1.473

0.062

1.575

4.59

20

19/32

0.037

0.927

0.040

1.003

0.066

1.676

0.070

1.778

6.41

38

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/21 Application and Description These PTFE insulated single-core MIL-W-22759/21 wires are used for MIL-Spec and Aerospace, They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires work especially well in applications where smoke emission, overload stability and flammability are major concerns.

Construction Details PTFE is extruded

Construction

Nickel plated high-strength copper conductor PTFE insulation

Conductor: Nickel plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 29 mil ( 0.70 mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 1000 volts SAE AS22759/21 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam.

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.015

0.38

0.041

1.041

0.045

1.143

1.93

26

19/38

0.019

0.48

0.046

1.168

0.050

1.270

2.60

24

19/36

0.024

0.61

0.051

1.295

0.055

1.397

3.38

22

19/34

0.030

0.76

0.058

1.473

0.062

1.575

4.61

20

19/32

0.038

0.97

0.066

1.676

0.070

1.778

6.43

www.caledonian-cables.co.uk

www.addison-cables.com

39


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/22 Application and Description These PTFE insulated single-core MIL-W-22759/22 wires are used for MIL-Spec and Aerospace, They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires work especially well in applications where smoke emission, overload stability and flammability are major concerns.

Construction Details PTFE is extruded

Construction

Silver plated high-strength copper conductor PTFE insulation

Conductor: Silver plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 19 mil ( 0.50 mm)

Characteristics Temperature Rating: 200째C Voltage Rating: 600 volts SAE AS22759/22 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Max in mm

Conductor Diam. Min in

mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.015

0.381

0.031

0.787

0.035

0.889

1.32

26

19/38

0.018

0.445

0.020

0.518

0.036

0.914

0.040

1.016

1.91

24

19/36

0.023

0.572

0.244

6.198

0.041

1.041

0.045

1.143

2.61

22

19/34

0.029

0.724

0.031

0.798

0.047

1.194

0.051

1.295

3.68

20

19/32

0.037

0.927

0.040

1.003

0.056

1.422

0.060

1.524

5.38

40

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/23 Application and Description These PTFE insulated single-core MIL-W-22759/23 wires are used for MIL-Spec and Aerospace, They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires work especially well in applications where smoke emission, overload stability and flammability are major concerns.

Construction Details PTFE is extruded

Construction

Nickel plated high-strength copper conductor PTFE insulation

Conductor: Nickel plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 33 mil ( 0.8 mm) to 58 mil ( 1.5mm)

Characteristics Temperature Rating: 260째C Voltage Rating: 600 volts SAE AS22759/23 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.031

0.787

0.035

0.889

1.34

26

19/38

0.018

0.445

0.0204

0.518

0.036

0.914

0.040

1.016

1.92

24

19/36

0.023

0.572

0.0254

0.645

0.041

1.041

0.045

1.143

2.63

22

19/34

0.029

0.724

0.0314

0.798

0.047

1.194

0.051

1.295

3.73

20

19/32

0.037

0.927

0.0404

1.026

0.056

1.422

0.060

1.524

5.44

www.caledonian-cables.co.uk

www.addison-cables.com

41


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/28 Application and Description These PTFE insulated single-core MIL-W-22759/28 wires are used for MIL-Spec and Aerospace, They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires work especially well in applications where smoke emission, overload stability and flammability are major concerns.

Construction Details PTFE is extruded

Construction Polyimide coating jacket Nickel plated high-strength copper conductor PTFE insulation

Conductor: Silver plated copper Insulation: Extruded PTFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Polyimide coating

Characteristics Temperature Rating: -55째C+200째C Voltage rating: 600 volts SAE AS22759/23 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.015

0.381

0.032

0.813

0.036

0.914

1.35

26

19/38

0.018

0.457

0.02

0.508

0.037

0.940

0.041

1.041

1.92

24

19/36

0.023

0.572

0.025

0.635

0.042

1.067

0.046

1.168

2.61

42

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

22

19/34

0.029

0.724

0.030

0.772

0.048

1.219

0.052

1.321

3.66

20

19/32

0.037

0.927

0.038

0.975

0.057

1.448

0.061

1.549

5.42

18

19/30

0.046

1.156

0.048

1.229

0.067

1.702

0.071

1.803

8.05

16

19/29

0.052

1.308

0.054

1.382

0.073

1.854

0.079

2.007

9.88

14

19/27

0.065

1.638

0.068

1.737

0.088

2.235

0.094

2.388

14.90

12

19/25

0.084

2.121

0.087

2.220

0.108

2.743

0.114

2.896

23.00

10

37/26

0.106

2.692

0.110

2.794

0.137

3.480

0.143

3.632

35.20

8

133/29

0.158

4.013

0.166

4.216

0.194

4.928

0.200

5.080

62.50

www.caledonian-cables.co.uk

www.addison-cables.com

43


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/29 Application and Description These PTFE insulation with a polyimide hard single-core MIL-W-22759/29 wires are used for MIL-Spec and Aerospace, These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns.

Construction Details PTFE is extruded

Construction Conductor: Nickel plated copper Insulation: Extruded PTFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Polyimide coating

Characteristics Temperature Rating: 260째C

Polyimide coating jacket

Voltage Rating: 600 volts

Nickel plated copper conductor

SAE AS22759/29

PTFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in

mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.032

0.813

0.036

0.914

1.37

26

19/38

0.016

0.406

0.022

0.559

0.037

0.940

0.041

1.041

1.99

24

19/36

0.023

0.584

0.024

0.610

0.042

1.067

0.046

1.168

2.73

22

19/34

0.029

0.737

0.031

0.787

0.048

1.219

0.052

1.321

3.77

20

19/32

0.037

0.94

0.039

0.991

0.057

1.448

0.061

1.549

5.55

18

19/30

0.046

1.168

0.049

1.245

0.067

1.702

0.071

1.803

8.15

16

19/29

0.052

1.321

0.053

1.346

0.073

1.854

0.079

2.007

10.10

14

19/27

0.065

1.651

0.069

1.753

0.088

2.235

0.094

2.388

15.30

12

19/25

0.087

2.210

0.086

2.184

0.108

2.743

0.114

2.896

23.60

10

37/26

0.106

2.692

0.112

2.845

0.137

3.480

0.143

3.632

36.10

8

133/29

0.158

4.013

0.169

4.293

0.198

5.029

0.204

5.182

64.80

44

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/30 Application and Description These PTFE insulation with a polyimide hard single-core MIL-W-22759/30 wires are used for MIL-Spec and Aerospace, These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns.

Construction Details PTFE is extruded

Construction Polyimide coating jacket Silver-plated high-strength copper conductor PTFE insulation

Conductor: Silver-plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Polyimide coating

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts SAE AS22759/30 Color Code: MIL-STD-681

Dimensions and Weight AWG Conductor Size Stranding 28 26 24 22 20

7/36 19/38 19/36 19/34 19/32

Conductor Diam. Min in mm 0.014 0.356 0.018 0.445 0.023 0.572 0.029 0.724 0.037 0.927

Conductor Diam. Max in mm 0.015 0.381 0.020 0.518 0.024 0.620 0.031 0.798 0.039 1.003

www.caledonian-cables.co.uk

Min O.D. in 0.032 0.037 0.042 0.048 0.057

mm 0.813 0.940 1.067 1.219 1.448

Max O.D. in 0.036 0.041 0.046 0.052 0.061

mm 0.914 1.041 1.168 1.321 1.549

www.addison-cables.com

Approx LBS/MFT 1.35 1.93 2.63 3.68 5.45

45


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/31 Application and Description: These PTFE insulation with a polyimide hard single-core MIL-W-22759/31 wires are used for MIL-Spec and Aerospace, These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns.

Construction Details PTFE is extruded

Construction Polyimide coating jacket Nickel plated high-strength copper conductor PTFE insulation

Conductor: Nickel plated high-strength copper alloy Insulation: Extruded PTFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Polyimide coating

Characteristics Temperature Rating: 260°C  Voltage Rating: 600 volts SAE AS22759/31 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.032

0.813

0.036

0.914

1.37

26

19/38

0.018

0.445

0.020

0.518

0.037

0.940

0.041

1.041

1.99

24

19/36

0.023

0.572

0.025

0.645

0.042

1.067

0.046

1.168

2.73

22

19/34

0.029

0.724

0.031

0.798

0.048

1.219

0.052

1.321

3.77

20

19/32

0.037

0.927

0.040

1.026

0.057

1.448

0.061

1.549

5.55

46

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/32 Application and Description These XL-ETFE insulation single-core MIL-W-22759/32 wires are used for MIL-Spec and Aerospace, These cable is a light weight, high temperature airframe and avionics wire which utilizes an insulation of cross-linked, modified ethylene tetrafluoroethylene copolymer (ETFE). ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals.

Construction Details Single layer over conductor

Construction Conductor: Tinned copper Insulation: Fluoropolymer Cross-linked Modified ETFE Single (XL-ETFE) Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-Spec WireÂ

Tin plated copper conductor

SAE AS22759/32

XL-ETFE insulation

Color Code: 10 basic colors

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

30

7/38

0.011

0.279

0.013

0.330

0.022

0.559

0.026

0.660

1

28

7/36

0.014

0.356

0.016

0.406

0.025

0.635

0.029

0.737

1

26

19/38

0.180

4.572

0.020

0.508

0.032

0.813

0.034

0.864

2

24

19/36

0.023

0.584

0.024

0.610

0.035

0.889

0.039

0.991

2

22

19/34

0.029

0.737

0.031

0.787

0.041

1.041

0.045

1.143

3

20

19/32

0.037

0.940

0.039

0.991

0.048

1.219

0.052

1.321

4

18

19/30

0.046

1.168

0.049

1.245

0.058

1.473

0.062

1.575

7

16

19/29

0.052

1.321

0.055

1.397

0.066

1.676

0.070

1.778

8

14

19/27

0.065

1.651

0.069

1.753

0.052

1.321

0.088

2.235

13

12

19/25

0.087

2.21

0.089

2.261

0.100

2.540

0.106

2.692

20

www.caledonian-cables.co.uk

www.addison-cables.com

47


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/33 Application and Description These XL-ETFE insulation single-core MIL-W-22759/33 wires are used for MIL-Spec and Aerospace, These cable is a light weight, high temperature airframe and avionics wire which utilizes an insulation of cross-linked, modified ethylene tetrafluoroethylene copolymer (ETFE). ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals. MIL-W-22759/33 wires are mechanically tough, flame retardant and weight saving.

Construction Details Single layer over conductor

Construction Conductor: Silver coated high strength copper alloy Insulation: Fluoropolymer Cross-linked Modified ETFE Single (XL-ETFE) Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec WireÂ

Silver plated high strength copper conductor

SAE AS22759/33

XL-ETFE insulation

Color Code: 10 basic colors

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

30

7/38

0.011

0.279

0.012

0.305

0.022

0.559

0.026

0.66

0.66

28

7/36

0.014

0.356

0.016

0.406

0.025

0.635

0.029

0.737

0.91

26

19/38

0.018

0.457

0.020

0.508

0.03

0.762

0.034

0.864

1.40

24

19/36

0.023

0.584

0.026

0.660

0.035

0.889

0.039

0.991

2.00

22

19/34

0.029

0.737

0.033

0.838

0.041

1.041

0.045

1.143

2.90

20

19/32

0.037

0.94

0.041

1.041

0.048

1.219

0.052

1.321

4.40

48

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/34 Application and Description These ETFE insulation single-core MIL-W-22759/34 wires are used for MIL-Spec and Aerospace, these cable is a normal weight, high temperature airframe and avionics wire which utilizes a dual layer insulation of cross-linked, modified ethylene tetrafluoroethylene copolymer (ETFE). The layers have contrasting colors to provide a visual indication of possible abrasion or other mechanical damage due to physical abuse during service or installation. ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals, MIL-W-22759/34 wires are mechanically tough, flame retardant and weight saving.

Construction Details Dual layers over conductor

Construction Treated aromatic polyamide braid XL-ETFE insulation Silver plated high strength copper conductor XL-ETFE insulation

Conductor: Tinned copper Insulation: Fluoropolymer Cross-linked Modified ETFE Dual Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: XL-ETFE Braid: Treated aromatic polyamide for size 2 and larger only

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/34 Color Code: 10 basic colors

www.caledonian-cables.co.uk

www.addison-cables.com

49


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

24

19/36

0.023

0.584

0.025

0.635

0.043

1.092

0.047

1.194

2.3

22

19/34

0.029

0.737

0.031

0.787

0.048

1.219

0.052

1.321

3.2

20

19/32

0.037

0.940

0.039

0.991

0.056

1.422

0.060

1.524

4.7

18

19/30

0.046

1.168

0.049

1.245

0.067

1.702

0.073

1.854

7.2

16

19/29

0.052

1.321

0.055

1.397

0.074

1.880

0.080

2.032

9.0

14

19/27

0.065

1.651

0.069

1.753

0.091

2.311

0.097

2.464

13.8

12

37/28

0.084

2.134

0.089

2.261

0.108

2.743

0.114

2.896

20.5

10

37/26

0.106

2.692

0.113

2.870

0.13

3.302

0.138

3.505

32.4

8

133/29

0.158

4.013

0.173

4.394

0.187

4.750

0.203

5.156

60.3

6

133/27

0.198

5.029

0.217

5.512

0.231

5.867

0.251

6.375

94.5

4

133/25

0.250

6.350

0.274

6.960

0.300

7.620

0.320

8.128

150.0

2

665/30

0.320

8.128

0.340

8.636

0.390

9.906

0.428

10.871

239.0

1

817/30

0.360

9.144

0.380

9.652

0.429

10.897

0.461

11.709

290.0

1/0

1045/30

0.395

10.033

0.425

10.795

0.469

11.913

0.501

12.725

377.0

2/0

1330/30

0.440

11.176

0.475

12.065

0.529

13.437

0.561

14.249

487.0

50

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/35 Application and Description These ETFE insulation single-core MIL-W-22759/35 wires are used for MIL-Spec and Aerospace, these cable is a normal weight, high temperature airframe and avionics wire which utilizes a dual layer insulation of cross-linked, modified ethylene tetrafluoroethylene copolymer (ETFE). The layers have contrasting colors to provide a visual indication of possible abrasion or other mechanical damage due to physical abuse during service or installation. ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals, MIL-W-22759/34 wires are mechanically tough, flame retardant and weight saving.

Construction Details Dual layers over conductor

Construction Conductor: Silver coated high strength copper alloy Insulation: Fluoropolymer Cross-linked Modified ETFE Dual Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Cross-linked ETFE

Characteristics Temperature Rating: 200°C

XL-ETFE insulation

Voltage Rating: 600 volts

Silver plated high strength copper conductor

MIL-Spec Wire

XL-ETFE insulation

SAE AS22759 Color Code: 10 basic colors

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in

mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.445

0.020

0.518

0.038

0.965

0.042

1.067

1.7

24

19/36

0.023

0.572

0.024

0.620

0.043

1.092

0.047

1.194

2.3

22

19/34

0.029

0.724

0.031

0.798

0.048

1.219

0.052

1.321

3.3

20

19/32

0.037

0.927

0.040

1.003

0.056

1.422

0.06

1.524

4.8

www.caledonian-cables.co.uk

www.addison-cables.com

51


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/41 Application and Description These ETFE insulation single-core MIL-W-22759/41 wires are used for MIL-Spec and Aerospace, These normal weight, high temperature airframe and avionics wires have contrasting colored insulation layers which provide a visual indication of possible abrasion or other mechanical damage due to physical abuse during service or installation. The insulation resists high PH cleaning fluids, lubricating oils, fuel and many other chemicals , MIL-W-22759/41 wires are mechanically tough, flame retardant and weight saving.

Construction Details Dual layers over conductor

Construction Treated aromatic polyamide braid XL-ETFE insulation Nickel plated copper conductor XL-ETFE insulation

Conductor: Nickel plated copper Insulation: Cross-linked ETFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: Cross-linked ETFE Braid: Treated aromatic polyamide for size 2 and larger only

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/41 Color Code: MIL-STD-681

52

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.457

0.020

0.508

0.038

0.965

0.042

1.067

1.7

24

19/36

0.023

0.584

0.025

0.635

0.043

1.092

0.047

1.194

2.3

22

19/34

0.029

0.737

0.031

0.787

0.048

1.219

0.052

1.321

3.2

20

19/32

0.037

0.940

0.039

0.991

0.056

1.422

0.06

1.524

4.7

18

19/30

0.046

1.168

0.049

1.245

0.067

1.702

0.073

1.854

7.2

16

19/29

0.052

1.321

0.053

1.346

0.074

1.880

0.080

2.032

9.0

14

19/27

0.065

1.651

0.069

1.753

0.091

2.311

0.097

2.464

13.8

12

37/28

0.084

2.134

0.089

2.261

0.108

2.743

0.114

2.896

20.5

10

37/26

0.106

2.692

0.112

2.845

0.130

3.302

0.138

3.505

32.4

8

133/29

0.158

4.013

0.169

4.293

0.187

4.750

0.203

5.156

60.3

6

133/27

0.198

5.029

0.213

5.41

0.231

5.867

0.251

6.375

94.5

4

133/25

0.250

6.350

0.268

6.807

0.300

7.620

0.320

8.128

150.0

2

665/30

0.320

8.128

0.340

8.636

0.390

9.906

0.428

10.871

239.0

1

817/30

0.360

9.144

0.380

9.652

0.429

10.897

0.461

11.709

290.0

1/0

1045/30

0.395

10.033

0.425

10.795

0.469

11.913

0.501

12.725

377.0

2/0

1330/30

0.440

11.176

0.475

12.065

0.529

13.437

0.561

14.249

518.0

www.caledonian-cables.co.uk

www.addison-cables.com

53


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/42 Application and Description These XL-ETFE insulation single-core MIL-W-22759/42 wires are used for MIL-Spec and Aerospace, These normal weight, high temperature airframe and avionics wires have contrasting colored insulation layers which provide a visual indication of possible abrasion or other mechanical damage due to physical abuse during service or installation. The insulation resists high PH cleaning fluids, lubricating oils, fuel and many other chemicals , MIL-W-22759/42 wires are mechanically tough, flame retardant and weight saving.

Construction Details Dual layers over conductor

Construction Conductor: Nickel coated high strength copper alloy Insulation: XL-ETFE Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: XL-ETFE

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts

XL-ETFE insulation

MIL-Spec WireÂ

Nickel coated high strength copper conductor

SAE AS22759/42

XL-ETFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.457

0.020

0.508

0.038

0.965

0.042

1.067

1.7

24

19/36

0.023

0.584

0.026

0.660

0.043

1.092

0.047

1.194

2.3

22

19/34

0.029

0.737

0.033

0.838

0.048

1.219

0.052

1.321

3.3

20

19/32

0.037

0.94

0.039

0.991

0.056

1.422

0.060

1.524

4.8

54

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/43 Application and Description These XL-ETFE insulation single-core MIL-W-22759/43 wires are used for MIL-Spec and Aerospace, These normal weight, high temperature airframe and avionics wires have contrasting colored insulation layers which provide a visual indication of possible abrasion or other mechanical damage due to physical abuse during service or installation. The insulation resists high PH cleaning fluids, lubricating oils, fuel and many other chemicals , MIL-W-22759/43 wires are mechanically tough, flame retardant and weight saving.

Construction Details Dual layers over conductor

Construction Treated aromatic polyamide braid XL-ETFE insulation Silver plated copper conductor XL-ETFE insulation

Conductor: Silver plated copper Insulation: Fluoropolymer Cross-linked Modified ETFE Dual Insulating Material Thickness: 10 mil ( 0.25 mm) Jacket: XL-ETFE Braid: Treated aromatic polyamide for size 2 and larger only

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/43 Color Code: MIL-STD-681

www.caledonian-cables.co.uk

www.addison-cables.com

55


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.015

0.381

0.025

0.635

0.029

0.737

0.9

26

19/38

0.018

0.457

0.019

0.483

0.038

0.965

0.042

1.067

1.7

24

19/36

0.023

0.584

0.025

0.635

0.043

1.092

0.047

1.194

2.3

22

19/34

0.029

0.737

0.031

0.787

0.048

1.219

0.052

1.321

3.2

20

19/32

0.037

0.940

0.039

0.991

0.056

1.422

0.06

1.524

4.7

18

19/30

0.046

1.168

0.049

1.245

0.067

1.702

0.073

1.854

7.2

16

19/29

0.052

1.321

0.055

1.397

0.074

1.880

0.080

2.032

9.0

14

19/27

0.065

1.651

0.069

1.753

0.091

2.311

0.097

2.464

13.8

12

37/28

0.084

2.134

0.089

2.261

0.108

2.743

0.114

2.896

20.5

10

37/26

0.106

2.692

0.113

2.870

0.130

3.302

0.138

3.505

32.4

8

133/29

0.158

4.013

0.173

4.394

0.187

4.750

0.203

5.156

61.9

6

133/27

0.198

5.029

0.217

5.512

0.231

5.867

0.251

6.375

94.5

4

133/25

0.250

6.350

0.274

6.960

0.300

7.620

0.32

8.128

158.0

2

665/30

0.320

8.128

0.340

8.636

0.390

9.906

0.428

10.871

239.0

1

817/30

0.360

9.144

0.380

9.652

0.429

10.897

0.461

11.709

305.0

1/0

1045/30

0.395

10.033

0.425

10.795

0.469

11.913

0.501

12.725

385.0

2/0

1330/30

0.440

11.176

0.475

12.065

0.529

13.437

0.561

14.249

487.0

56

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/44 Application and Description These XL-ETFE insulation single-core MIL-W-22759/44 wires are used for MIL-Spec and Aerospace, ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals, MIL-W-22759/44 wires are mechanically tough, flame retardant and weight saving.

Construction Details Single layer over conductor

Construction Conductor: Soft, annealed silver plated copper Insulation: Fluoropolymer Cross-linked Modified ETFE Single Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec WireÂ

Silver plated copper conductor

SAE AS22759/44

XL-ETFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Min O.D.

Approx LBS/ MFT

Max O.D.

in

mm

in

mm

28

7/36

0.0250

0.635

0.029

0.737

0.9

26

19/38

0.030

0.762

0.034

0.864

1.4

24

19/36

0.035

0.889

0.039

0.991

2.0

22

19/34

0.041

1.041

0.045

1.143

2.8

20

19/32

0.048

1.219

0.052

1.321

4.3

18

19/30

0.058

1.473

0.062

1.575

6.5

16

19/29

0.066

1.676

0.070

1.778

8.3

14

19/27

0.082

2.083

0.088

2.235

13.0

12

37/28

0.100

2.540

0.106

2.692

19.7

www.caledonian-cables.co.uk

www.addison-cables.com

57


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/45 Application and Description These XL-ETFE insulation single-core MIL-W-22759/45 wires are used for MIL-Spec and Aerospace, ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals, MIL-W-22759/45 wires are mechanically tough, flame retardant and weight saving.

Construction Details Single layer over conductor

Construction Conductor: Nickel coated copper Insulation: XL-ETFE Single Layer Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec WireÂ

Nickel coated copper conductor

SAE AS22759/45

XL-ETFE insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.025

0.635

0.029

0.737

0.9

26

19/38

0.018

0.457

0.022

0.559

0.030

0.762

0.034

0.864

1.4

24

19/36

0.023

0.584

0.024

0.610

0.035

0.889

0.039

0.991

2.0

22

19/34

0.029

0.737

0.031

0.787

0.041

1.041

0.045

1.143

2.8

20

19/32

0.037

0.940

0.039

0.991

0.048

1.219

0.052

1.321

4.3

18

19/30

0.046

1.168

0.049

1.245

0.058

1.473

0.062

1.575

6.5

16

19/29

0.052

1.321

0.053

1.346

0.066

1.676

0.070

1.778

8.3

14

19/27

0.065

1.651

0.069

1.753

0.082

2.083

0.088

2.235

13.0

12

37/28

0.084

2.134

0.089

2.261

0.100

2.540

0.106

2.692

19.7

58

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/46 Application and Description These XL-ETFE insulation single-core MIL-W-22759/46 wires are used for MIL-Spec and Aerospace, ETFE insulation resists high PH cleaning fluids, fuels, lubricants and many other chemicals, MIL-W-22759/46 wires are mechanically tough, flame retardant and weight saving.

Construction Details Single layer over conductor

Construction Conductor: Nickel plated high strength Copper Insulation: XL-ETFE Single Layer Insulating Material Thickness: 6 mil ( 0.15 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts

Nickel plated high strength copper conductor

MIL-Spec WireÂ

XL-ETFE insulation

SAE AS22759/46 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

28

7/36

0.014

0.356

0.016

0.406

0.025

0.635

0.029

0.737

0.9

26

19/38

0.018

0.457

0.020

0.508

0.030

0.762

0.034

0.864

1.4

24

19/36

0.023

0.584

0.026

0.660

0.035

0.889

0.039

0.991

2.0

22

19/34

0.029

0.737

0.033

0.838

0.041

1.041

0.045

1.143

2.9

20

19/32

0.037

0.940

0.039

0.991

0.048

1.219

0.052

1.321

4.4

www.caledonian-cables.co.uk

www.addison-cables.com

59


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/80 Application and Description These PTFE tape insulation single-core MIL-W-22759/80 wires are used for MIL-Spec and Aerospace, these cables are light-weight, high-performance aerospace hook up wires with a dual-layer insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability, light weight and high break strength.

Construction Details A PTFE/K/PTFE layer construction

Construction Conductor: Tin plated copper Insulation: Light Weight Fluoropolymer/Polyimide Tape Insulating Material Thickness: 13 mil ( 0.30 mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-Spec WireÂ

Tin plate copper conductor

SAE AS22759/80

Fluoropolymer/polyimide tapes

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.445

0.020

0.518

0.03

0.762

0.034

0.864

1.43

24

19/36

0.023

0.572

0.024

0.620

0.034

0.864

0.038

0.965

1.93

22

19/34

0.029

0.724

0.031

0.798

0.04

1.016

0.043

1.092

2.85

20

19/32

0.037

0.927

0.039

1.001

0.048

1.219

0.051

1.295

4.38

18

19/30

0.046

1.156

0.049

1.255

0.056

1.422

0.060

1.524

6.60

16

19/29

0.052

1.308

0.055

1.407

0.063

1.600

0.067

1.702

8.30

14

19/27

0.065

1.638

0.069

1.763

0.076

1.930

0.080

2.032

12.60

12

37/28

0.084

2.121

0.089

2.271

0.096

2.438

0.100

2.540

19.60

10

37/26

0.106

2.692

0.112

2.845

0.119

3.023

0.123

3.124

30.60

60

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/81 Application and Description These PTFE tape insulation single-core MIL-W-22759/81 wires are used for MIL-Spec and Aerospace, these cables are light-weight, high-performance aerospace hook up wires with a dual-layer insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability, light weight and high break strength.

Construction Details A PTFE/K/PTFE layer construction

Construction

Silver plated high strength copper conductor Fluoropolymer/polyimide tapes

Conductor: Silver plated high strength copper alloy Insulation: Light Weight Fluoropolymer/Polyimide Tape Insulating Material Thickness: 13 mil ( 0.30 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/81 Color Code: MIL-STD-681

Dimensions and Weight AWG Size 26 24 22 20

Conductor Stranding 19/38 19/36 19/34 19/32

Conductor Diam. Min in mm 0.018 0.445 0.023 0.572 0.029 0.724 0.037 0.927

Conductor Diam. Max in 0.020 0.024 0.031 0.040

mm 0.518 0.620 0.798 1.003

www.caledonian-cables.co.uk

Min O.D. in 0.030 0.034 0.040 0.048

mm 0.762 0.864 1.016 1.219

Max O.D. in 0.034 0.038 0.043 0.051

mm 0.864 0.965 1.092 1.295

www.addison-cables.com

Approx LBS/ MFT 1.43 1.93 2.85 4.38

61


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/82 Application and Description These PTFE tape insulation single-core MIL-W-22759/82 wires are used for MIL-Spec and Aerospace, these cables are light-weight, high-performance aerospace hook up wires with a dual-layer insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability, light weight and high break strength.

Construction Details A PTFE/K/PTFE layer construction

Construction

Nickel plated high strength copper conductor Fluoropolymer/polyimide tapes

Conductor: Nickel plated high strength copper alloy Insulation: Light Weight Fluoropolymer/Polyimide Tape Insulating Material Thickness: 13 mil ( 0.30 mm)

Characteristics Temperature Rating: 260°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/82 Color Code: MIL-STD-681

Dimensions and Weight AWG Size 26 24 22 20

62

Conductor Stranding 19/38 19/36 19/34 19/32

Conductor Diam. Min in 0.018 0.023 0.029 0.037

mm 0.445 0.572 0.724 0.927

www.caledonian-cables.co.uk

Conductor Diam. Max in mm 0.020 0.518 0.025 0.645 0.031 0.798 0.040 1.026

Min O.D. in 0.030 0.034 0.040 0.048

mm 0.762 0.864 1.016 1.219

Max O.D. in 0.034 0.038 0.043 0.051

www.addison-cables.com

mm 0.864 0.965 1.092 1.295

Approx LBS/ MFT 1.43 1.93 2.85 4.38


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/83 Application and Description These PTFE tape insulation single-core MIL-W-22759/83 wires are used for MIL-Spec and Aerospace, these cables are large size, high-performance aerospace hook up wires with a four-layer insulation of PTFE tape and PTFE/polyimide/PTFE tape, with an outer layer of polyamide braid for superior abrasion resistance. These wires are designed for aerospace and other applications which require excellent thermal stability and abrasion resistance.

Construction Details A PTFE layer with an intermediate K layer followed by two top PTFE layers Over these layers is a braid of an Aramid.

Construction Conductor: Silver plated copper Insulation: Fluoropolymer/Polyimide Tape Braid: Aramid (option) Insulating Material Thickness: Size 2 to 1 - 40 mil ( 1.0 mm) Size 1/0 to 4/0 - 50 mil ( 1.3 mm)

Characteristics Temperature Rating: 200°C

Aramid(option)

Voltage Rating: 600 volts

Nickel plated high strength copper conductor

MIL-Spec WireÂ

Fluoropolymer/polyimide tapes

SAE AS22759/83 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min In Mm

Conductor Diam. Max In mm

Min O.D.

Max O.D.

(in)

mm

(in)

mm

Approx LBS/ MFT

2

665/30

0.320

8.128

0.340

8.636

0.360

9.144

0.380

9.652

227

1

817/30

0.366

9.296

0.380

9.652

0.400

10.160

0.420

10.668

295

1/0

1045/30

0.395

10.033

0.425

10.795

0.442

11.227

0.462

11.735

351

2/0

1330/30

0.440

11.176

0.475

12.065

0.498

12.649

0.528

13.411

432

3/0

1665/30

0.500

12.700

0.540

13.716

0.554

14.072

0.584

14.834

542

4/0

2109/30

0.565

14.351

0.605

15.367

0.615

15.621

0.655

16.637

689

www.caledonian-cables.co.uk

www.addison-cables.com

63


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/84 Application and Description These PTFE tape insulation single-core MIL-W-22759/84 wires are used for MIL-Spec and Aerospace, these cables are large size, high-performance aerospace hook up wires with a four-layer insulation of PTFE tape and PTFE/polyimide/PTFE tape, with an outer layer of polyamide braid for superior abrasion resistance. These wires are designed for aerospace and other applications which require excellent thermal stability and abrasion resistance.

Construction Details A PTFE layer with an intermediate K layer followed by two top PTFE layers Over these layers is a braid of an Aramid.

Construction Conductor: Nickel plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: Size 2 to 1 - 40 mil ( 1.0 mm) Size 1/0 to 4/0 - 50 mil ( 1.3 mm) Braid: Aramid (option)

Characteristics Temperature Rating: 260°C Voltage Rating: 600 volts

Aramid(option)

MIL-Spec WireÂ

Nickel plated copper conductor

SAE AS22759/84

Fluoropolymer/polyimide tapes

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min In Mm

Conductor Diam. Max

Min O.D.

Max O.D.

In

mm

(in)

Mm

(in)

mm

Approx LBS/ MFT

2

665/30

0.320

8.128

0.340

8.636

0.360

9.144

0.380

9.652

227

1

817/30

0.366

9.296

0.380

9.652

0.400

10.160

0.420

10.668

295

1/0

1045/30

0.395

10.033

0.425

10.795

0.442

11.227

0.462

11.735

351

2/0

1330/30

0.440

11.176

0.475

12.065

0.498

12.649

0.528

13.411

432

3/0

1665/30

0.500

12.700

0.540

13.716

0.554

14.072

0.584

14.834

542

4/0

2109/30

0.565

14.351

0.605

15.367

0.615

15.621

0.655

16.637

689

64

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/85 Application and Description These PTFE tape insulation single-core MIL-W-22759/84 wires are used for MIL-Spec and Aerospace, these cables are large size, high-performance aerospace hook up wires with a four-layer insulation of PTFE tape and PTFE/polyimide/PTFE tape, with an outer layer of polyamide braid for superior abrasion resistance. These wires are designed for aerospace and other applications which require excellent thermal stability and abrasion resistance.

Construction Details A PTFE layer with an intermediate K layer followed by two top PTFE layers Over these layers is a braid of an Aramid.

Construction Conductor: Tin plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: Size 2 to 1 - 40 mil ( 1.0 mm) Size 1/0 to 4/0 - 50 mil ( 1.3 mm) Braid: Aramid (option)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts

Aramid(option)

MIL-Spec WireÂ

Tin plated copper conductor

SAE AS22759/85

Fluoropolymer/polyimide tapes

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

2

665/30

0.320

8.128

0.340

8.636

0.360

9.144

0.380

9.652

227

1

817/30

0.366

9.296

0.380

9.652

0.400

10.160

0.420

10.668

295

1/0

1045/30

0.395

10.033

0.425

10.795

0.442

11.227

0.462

11.735

351

2/0

1330/30

0.440

11.176

0.475

12.065

0.498

12.649

0.528

13.411

432

3/0

1665/30

0.500

12.700

0.540

13.716

0.554

14.072

0.584

14.834

542

4/0

2109/30

0.565

14.351

0.605

15.367

0.615

15.621

0.655

16.637

689

www.caledonian-cables.co.uk

www.addison-cables.com

65


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/86 Application and Description These PTFE tape insulation single-core MIL-W-22759/86 wires are used for MIL-Spec and Aerospace, these cables are normal weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape in several configurations. These wires are designed for aerospace and other applications which require excellent thermal stability and good abrasion resistance.

Construction Details Sizes 10 to 26 have a PTFE/K/PTFE layer construction. Sizes 6 to 8 have a PTFE layer with an intermediate K layer and a top PTFE layer. Sizes 4 to 4/0 have a PTFE layer with an intermediate K layer and two top PTFE layers.

Construction

Silver plated copper conductor Fluoropolymer/Polyimide Tape Insulation

Conductor: Silver plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: Size 10 to 26 - 16 mil ( 0.5 mm) Size 6 to 8 - 22 mil ( 0.6 mm) Size 4 - 25 mil ( 0.6 mm) Size 2 to 4/0 - 25 mil ( 0.6 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/86 Color Code: MIL-STD-681

66

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.445

0.0194

0.493

0.033

0.838

0.037

0.94

1.55

24

19/36

0.023

0.572

0.0244

0.620

0.038

0.965

0.042

1.067

2.20

22

19/34

0.029

0.724

0.0304

0.772

0.043

1.092

0.047

1.194

3.00

20

19/32

0.037

0.927

0.0384

0.975

0.051

1.295

0.055

1.397

4.55

18

19/30

0.046

1.156

0.0484

1.229

0.061

1.549

0.065

1.651

6.70

16

19/29

0.052

1.308

0.0544

1.382

0.068

1.727

0.073

1.854

8.60

14

19/27

0.065

1.638

0.0684

1.737

0.081

2.057

0.086

2.184

12.95

12

37/28

0.084

2.121

0.0874

2.220

0.100

2.540

0.105

2.667

20.10

10

37/26

0.106

2.692

0.110

2.794

0.122

3.099

0.127

3.226

31.40

8

133/29

0.158

4.013

0.166

4.216

0.180

4.572

0.188

4.775

57.60

6

133/27

0.198

5.029

0.208

5.283

0.219

5.563

0.229

5.817

88.30

4

133/27

0.250

6.350

0.263

6.680

0.276

7.010

0.288

7.315

143.00

2

665/30

0.320

8.128

0.340

8.636

0.344

8.738

0.364

9.246

223.00

1

817/30

0.366

9.296

0.380

9.652

0.388

9.855

0.408

10.363

289.00

1/0

1045/30

0.395

10.033

0.425

10.795

0.420

10.668

0.450

11.43

345.00

2/0

1330/30

0.440

11.176

0.475

12.065

0.475

12.065

0.505

12.827

432.00

3/0

1665/30

0.500

12.700

0.540

13.716

0.530

13.462

0.560

14.224

542.00

4/0

2109/30

0.565

14.351

0.605

15.367

0.590

14.986

0.630

16.002

681.00

www.caledonian-cables.co.uk

www.addison-cables.com

67


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/87 Application and Description These PTFE tape insulation single-core MIL-W-22759/87 wires are used for MIL-Spec and Aerospace, these cables are normal weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape in several configurations. These wires are designed for aerospace and other applications which require excellent thermal stability and good abrasion resistance.

Construction Details Sizes 10 to 26 have a PTFE/K/PTFE layer construction. Sizes 6 to 8 have a PTFE layer with an intermediate K layer and a top PTFE layer. Sizes 4 to 4/0 have a PTFE layer with an intermediate K layer and two top PTFE layers.

Construction

Nickel plated copper conductor Fluoropolymer/Polyimide Tape Insulation

Conductor: Nickel plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: Size 10 to 26 - 16 mil ( 0.5 mm) Size 6 to 8 - 22 mil ( 0.6 mm) Size 4 - 25 mil ( 0.6 mm) Size 2 to 4/0 - 25 mil ( 0.6 mm)

Characteristics Temperature Rating: 260°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/87 Color Code: MIL-STD-681

68

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

Min O.D.

Max O.D.

In

Mm

In

mm

(in)

mm

(in)

mm

Approx LBS/ MFT

26

19/38

0.018

0.445

0.020

0.518

0.033

0.838

0.037

0.940

1.55

24

19/36

0.023

0.572

0.024

0.620

0.038

0.965

0.042

1.067

2.15

22

19/34

0.029

0.724

0.031

0.798

0.043

1.092

0.047

1.194

3.00

20

19/32

0.037

0.927

0.039

1.001

0.051

1.295

0.055

1.397

4.55

18

19/30

0.046

1.156

0.049

1.255

0.061

1.549

0.065

1.651

6.70

16

19/29

0.052

1.308

0.055

1.407

0.068

1.727

0.073

1.854

8.60

14

19/27

0.065

1.638

0.069

1.763

0.081

2.057

0.086

2.184

12.95

12

37/28

0.084

2.121

0.089

2.271

0.100

2.540

0.105

2.667

20.10

10

37/26

0.106

2.692

0.112

2.845

0.122

3.099

0.127

3.226

31.40

8

133/29

0.158

4.013

0.169

4.293

0.18

4.572

0.188

4.775

57.60

6

133/27

0.198

5.029

0.212

5.385

0.219

5.563

0.229

5.817

88.30

4

133/25

0.250

6.350

0.268

6.807

0.276

7.010

0.288

7.315

143.00

2

665/30

0.320

8.128

0.340

8.636

0.344

8.738

0.364

9.246

222.00

1

817/30

0.366

9.296

0.380

9.652

0.388

9.855

0.408

10.363

289.00

1/0

1045/30

0.395

10.033

0.425

10.795

0.420

10.668

0.450

11.430

345.00

2/0

1330/30

0.440

11.176

0.476

12.090

0.475

12.065

0.505

12.827

432.00

3/0

1665/30

0.500

12.70

0.540

13.716

0.530

13.462

0.560

14.224

542.00

4/0

2109/30

0.565

14.351

0.605

15.367

0.590

14.986

0.630

16.002

681.00

www.caledonian-cables.co.uk

www.addison-cables.com

69


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/88 Application and Description These PTFE tape insulation single-core MIL-W-22759/88 wires are used for MIL-Spec and Aerospace, these cables are normal weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape in several configurations. These wires are designed for aerospace and other applications which require excellent thermal stability and good abrasion resistance.

Construction Details Sizes 10 to 26 have a PTFE/K/PTFE layer construction. Sizes 6 to 8 have a PTFE layer with an intermediate K layer and a top PTFE layer. Sizes 4 to 4/0 have a PTFE layer with an intermediate K layer and two top PTFE layers.

Construction

Tin plated copper conductor Fluoropolymer/Polyimide Tape Insulation

Conductor: Tin plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: Size 10 to 26 - 16 mil ( 0.5 mm) Size 6 to 8 - 22 mil ( 0.6 mm) Size 4 - 25 mil ( 0.6 mm) Size 2 to 4/0 - 25 mil ( 0.6 mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/88 Color Code: MIL-STD-681

70

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min In Mm

Conductor Diam. Max In mm

Min O.D.

Max O.D.

(in)

mm

(in)

mm

Approx LBS/ MFT

26

19/38

0.033

0.838

0.037

0.940

0.033

0.838

0.037

0.940

1.55

24

19/36

0.038

0.965

0.042

1.067

0.038

0.965

0.042

1.067

2.15

22

19/34

0.043

1.092

0.047

1.194

0.043

1.092

0.047

1.194

3.00

20

19/32

0.051

1.295

0.055

1.397

0.051

1.295

0.055

1.397

4.55

18

19/30

0.061

1.549

0.065

1.651

0.061

1.549

0.065

1.651

6.70

16

19/29

0.068

1.727

0.073

1.854

0.068

1.727

0.073

1.854

8.60

14

19/27

0.081

2.057

0.083

2.108

0.081

2.057

0.086

2.184

12.95

12

37/28

0.100

2.540

0.105

2.667

0.100

2.540

0.105

2.667

20.10

10

37/26

0.122

3.099

0.127

3.226

0.122

3.099

0.127

3.226

31.40

8

133/29

0.180

4.572

0.188

4.775

0.18

4.572

0.188

4.775

57.60

6

133/27

0.219

5.563

0.229

5.817

0.219

5.563

0.229

5.817

88.30

4

133/25

0.276

7.010

0.288

7.315

0.276

7.010

0.288

7.315

143.00

2

665/30

0.344

8.738

0.364

9.246

0.344

8.738

0.364

9.246

222.00

1

817/30

0.388

9.855

0.408

10.363

0.388

9.855

0.408

10.363

289.00

1/0

1045/30

0.420

10.668

0.450

11.430

0.420

10.668

0.45

11.430

345.00

2/0

1330/30

0.475

12.065

0.505

12.827

0.475

12.065

0.505

12.827

432.00

3/0

1665/30

0.550

13.970

0.560

14.224

0.530

13.462

0.560

14.224

542.00

4/0

2109/30

0.590

14.986

0.630

16.002

0.590

14.986

0.630

16.002

681.00

www.caledonian-cables.co.uk

www.addison-cables.com

71


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/89 Application and Description These PTFE tape insulation single-core MIL-W-22759/89 wires are used for MIL-Spec and Aerospace, these cables are normal weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability and high break strength.

Construction Details A PTFE/K/PTFE layer construction

Construction Conductor: Silver plated high strength copper alloy Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: 14 mil ( 0.40 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts MIL-Spec WireÂ

Silver plated high strength copper conductor

SAE AS22759/89

Fluoropolymer/Polyimide Tape Insulation

Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min

Conductor Diam. Max

in

mm

in

mm

in

mm

in

mm

Min O.D.

Max O.D.

Approx LBS/ MFT

26

19/38

0.0175

0.445

0.0204

0.518

0.033

0.838

0.037

0.94

1.55

24

19/36

0.0225

0.572

0.0244

0.62

0.038

0.965

0.042

1.067

2.15

22

19/34

0.0285

0.724

0.0314

0.798

0.043

1.092

0.047

1.194

3

20

19/32

0.0365

0.927

0.0395

1.003

0.051

1.295

0.055

1.397

4.55

72

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/90 Application and Description These PTFE tape insulation single-core MIL-W-22759/90 wires are used for MIL-Spec and Aerospace, these cables are normal weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability and high break strength.

Construction Details A PTFE/K/PTFE layer construction

Construction

Nickel plated high strength copper conductor Fluoropolymer/Polyimide Tape Insulation

Conductor: Nickel plated high strength copper alloy Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: 14 mil ( 0.40 mm)

Characteristics Temperature Rating: 260°C Voltage Rating: 600 volts MIL-Spec Wire SAE AS22759/90 Color Code: MIL-STD-681

Dimensions and Weight AWG Size 26 24 22 20

Conductor Stranding 19/38 19/36 19/34 19/32

Conductor Diam. Min in 0.018 0.023 0.029 0.037

mm 0.440 0.570 0.720 0.930

Conductor Diam. Max in mm 0.020 0.520 0.025 0.650 0.031 0.800 0.040 1.030

www.caledonian-cables.co.uk

Min O.D. in 0.033 0.038 0.043 0.051

mm 0.838 0.965 1.092 1.295

Max O.D. in 0.037 0.042 0.047 0.055

mm 0.940 1.067 1.194 1.397

www.addison-cables.com

Approx LBS/ MFT 1.55 2.15 3.00 4.55

73


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/91 Application and Description These PTFE tape insulation single-core MIL-W-22759/91 wires are used for MIL-Spec and Aerospace, these cables are light weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability and light weight

Construction Details A PTFE/K/PTFE layer construction

Construction Conductor: Silver plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: 13 mil ( 0.30 mm)

Characteristics Temperature Rating: 200°C Voltage Rating: 600 volts

Silver plated copper conductor

MIL-Spec WireÂ

Fluoropolymer/Polyimide tape insulation

SAE AS22759/91 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max

Min O.D.

Max O.D.

in

mm

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.440

0.019

0.490

0.030

0.762

0.034

0.864

1.43

24

19/36

0.023

0.570

0.024

0.620

0.034

0.864

0.038

0.965

1.93

22

19/34

0.029

0.720

0.030

0.770

0.040

1.016

0.043

1.092

2.85

20

19/32

0.037

0.930

0.038

0.980

0.048

1.219

0.051

1.295

4.38

18

19/30

0.046

1.160

0.048

1.230

0.056

1.422

0.060

1.524

6.60

16

19/29

0.052

1.310

0.054

1.380

0.063

1.600

0.067

1.702

8.30

14

19/27

0.065

1.640

0.068

1.740

0.076

1.930

0.080

2.032

12.60

12

37/28

0.084

2.120

0.087

2.220

0.096

2.438

0.100

2.540

19.60

10

37/26

0.106

2.690

0.110

2.790

0.119

3.023

0.123

3.124

30.60

74

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-22759/92 Application and Description These PTFE tape insulation single-core MIL-W-22759/92 wires are used for MIL-Spec and Aerospace, these cables are light weight, high-performance, aerospace hook up wires with insulation composed of PTFE/polyimide/PTFE tape and PTFE tape. These wires are designed for aerospace and other applications which require excellent thermal stability and light weight

Construction Details A PTFE/K/PTFE layer construction

Construction Conductor: Nickel plated copper Insulation: Fluoropolymer/Polyimide Tape Insulating Material Thickness: 13 mil ( 0.30 mm)

Characteristics Temperature Rating: 260°C Voltage Rating: 600 volts

Nickel plated copper conductor

MIL-Spec WireÂ

Fluoropolymer/Polyimide tape insulation

SAE AS22759/92 Color Code: MIL-STD-681

Dimensions and Weight AWG Size

Conductor Stranding

Conductor Diam. Min in mm

Conductor Diam. Max in mm

Min O.D.

Max O.D.

in

mm

in

mm

Approx LBS/ MFT

26

19/38

0.018

0.440

0.020

0.520

0.030

0.762

0.034

0.864

1.43

24

19/36

0.023

0.570

0.024

0.620

0.034

0.864

0.038

0.965

1.93

22

19/34

0.029

0.720

0.031

0.800

0.040

1.016

0.043

1.092

2.85

20

19/32

0.037

0.930

0.039

1.000

0.048

1.219

0.051

1.295

4.38

18

19/30

0.046

1.160

0.049

1.250

0.056

1.422

0.060

1.524

6.60

16

19/29

0.052

1.310

0.055

1.410

0.063

1.600

0.067

1.702

8.30

14

19/27

0.065

1.640

0.069

1.760

0.076

1.930

0.08

2.032

12.60

12

37/28

0.084

2.120

0.089

2.270

0.096

2.438

0.100

2.540

19.60

10

37/26

0.106

2.690

0.112

2.840

0.119

3.023

0.123

3.124

30.60

www.caledonian-cables.co.uk

www.addison-cables.com

75


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/5 Applications MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction XL-PVDF Silver plated Copper Irradiation cross-linked extruded Polyalkene

Conductor: Silver plated Copper Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 30 mil ( 0.8 mm) to 85 mil ( 2.2mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/5 SAE AS81044 10 basic colors

76

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight

AWG Size

Conductor Stranding

Min O.D.

Approx LBS/ MFT

Max O.D.

In

Mm

In

mm

24

19/36

0.055

1.397

0.059

1.499

3.00

22

19/34

0.066

1.676

0.072

1.829

4.30

20

19/32

0.075

1.905

0.081

2.057

6.10

18

19/30

0.085

2.159

0.091

2.311

8.70

16

19/29

0.095

2.413

0.101

2.565

10.90

14

19/27

0.111

2.819

0.119

3.023

16.20

12

37/28

0.127

3.226

0.135

3.429

24.20

10

37/26

0.156

3.962

0.166

4.216

36.50

8

133/29

0.213

5.410

0.225

5.715

65.00

6

133/27

0.262

6.655

0.276

7.010

103.00

4

133/25

0.317

8.052

0.333

8.458

158.00

2

665/30

0.392

9.957

0.416

10.566

252.00

1/0

1045/30

0.478

12.141

0.510

12.954

380.00

www.caledonian-cables.co.uk

www.addison-cables.com

77


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/6 Applications MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction

XL-PVDF Silver plated high strength Copper Irradiation cross-linked extruded Polyalkene

Conductor: Stranded tinned copper Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 30 mil ( 0.8 mm) to 80 mil ( 2.0mm) Does not include the over braid (see below)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/6 SAE AS81044 10 basic colors

78

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight

AWG Size

Conductor Stranding

Min O.D.

Max O.D.

In

Mm

In

mm

Approx LBS/MFT

24

19/36

0.055

1.397

0.059

1.499

3.00

22

19/34

0.066

1.676

0.072

1.829

4.30

20

19/32

0.075

1.905

0.081

2.057

6.10

18

19/30

0.085

2.159

0.091

2.311

8.70

16

19/29

0.093

2.362

0.101

2.565

10.90

14

19/27

0.111

2.819

0.119

3.023

16.20

12

37/28

0.127

3.226

0.135

3.429

24.20

10

37/26

0.156

3.962

0.166

4.216

36.50

8

133/29

0.213

5.410

0.225

5.715

65.00

6

133/27

0.262

6.655

0.276

7.010

103.00

4

133/25

0.317

8.052

0.333

8.458

158.00

2

665/30

0.405

10.287

0.431

10.947

252.00

1

817/30

0.445

11.303

0.475

12.065

305.00

1/0

1045/30

0.491

12.471

0.525

13.335

380.00

www.caledonian-cables.co.uk

www.addison-cables.com

79


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/7 Applications MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction Conductor: Silver plated high strength Copper Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 34 mil ( 0.9 mm) to 39 mil ( 1.0mm)

Characteristics Temperature Rating: 150°C

XL-PVDF Silver plated high strength Copper

Voltage Rating:Â 600 volts MIL-W-81044/7

Irradiation cross-linked extruded Polyalkene

SAE AS81044 10 basic colors

Dimensions and Weight AWG Size

Conductor Stranding

Min O.D.

Max O.D.

In

Mm

In

mm

Approx LBS/ MFT

26

19/38

0.051

1.295

0.055

1.397

2.20

24

19/36

0.055

1.397

0.059

1.499

3.00

22

19/34

0.066

1.676

0.072

1.829

4.30

20

19/32

0.075

1.905

0.081

2.057

6.10

80

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/8 Applications: MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction

XL-PVDF Silver plated Copper Irradiation cross-linked extruded Polyalkene

Conductor: Silver plated Copper Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 30 mil ( 0.8 mm) to 85 mil ( 2.2mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/7 SAE AS81044 10 basic colors

www.caledonian-cables.co.uk

www.addison-cables.com

81


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

82

Conductor Stranding

Min O.D.

Max O.D.

In

Mm

In

mm

Approx LBS/ MFT

24

19/36

0.052

1.321

0.056

1.422

2.70

22

19/34

0.059

1.499

0.065

1.651

3.90

20

19/32

0.067

1.702

0.073

1.854

5.50

18

19/30

0.077

1.956

0.083

2.108

8.00

16

19/29

0.085

2.159

0.093

2.362

10.10

14

19/27

0.104

2.642

0.112

2.845

15.50

12

37/28

0.122

3.099

0.130

3.302

23.00

10

37/26

0.150

3.810

0.160

4.064

35.70

8

133/29

0.208

5.283

0.220

5.588

62.80

6

133/27

0.257

6.528

0.271

6.883

99.30

4

133/25

0.312

7.925

0.328

8.331

153.00

2

665/30

0.388

9.855

0.412

10.465

247.00

1/0

1045/30

0.474

12.040

0.506

12.852

377.00

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/9 Applications: MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction

XL-PVDF

Tin plated Copper

Irradiation cross-linked extruded Polyalkene

Conductor: Tin plated Copper Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 30 mil ( 0.8 mm) to 85 mil ( 2.2mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/9 SAE AS81044 10 basic colors

www.caledonian-cables.co.uk

www.addison-cables.com

83


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight AWG Size

Conductor Stranding

Min O.D.

Approx LBS/ MFT

Max O.D.

In

Mm

In

mm

24

19/36

0.052

1.321

0.056

1.422

2.70

22

19/34

0.059

1.499

0.065

1.651

3.90

20

19/32

0.067

1.702

0.073

1.854

5.50

18

19/30

0.077

1.956

0.083

2.108

8.00

16

19/29

0.085

2.159

0.093

2.362

10.10

14

19/27

0.104

2.642

0.112

2.845

15.50

12

37/28

0.122

3.099

0.130

3.302

23.00

10

37/26

0.150

3.810

0.160

4.064

35.70

8

133/29

0.208

5.283

0.220

5.588

62.80

6

133/27

0.257

6.528

0.271

6.883

99.30

4

133/25

0.321

8.153

0.328

8.331

153.00

2

665/30

0.388

9.855

0.412

10.465

247.00

1/0

1045/30

0.474

12.040

0.506

12.852

377.00

84

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/10 Applications MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction Conductor: Stranded silver-plated high strength copper alloy conductor Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 29 mil ( 0.7 mm) to 32 mil ( 0.8mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts

XL-PVDF

MIL-W-81044/10

Stranded silver-plated high strength copper alloy conductor

SAE AS81044

Irradiation cross-linked extruded Polyalkene

10 basic colors

Dimensions and Weight AWG Size

Conductor Stranding

Min O.D.

Approx LBS/MFT

Max O.D.

In

Mm

In

mm

26

19/38

0.046

1.168

0.050

1.270

1.90

24

19/36

0.052

1.321

0.056

1.422

2.70

22

19/34

0.059

1.499

0.065

1.651

3.90

20

19/32

0.067

1.702

0.073

1.854

5.50

www.caledonian-cables.co.uk

www.addison-cables.com

85


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/11 Applications: MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction

XL-PVDF

Stranded soft annealed silver-plated copper Irradiation cross-linked extruded Polyalkene

Conductor: Stranded soft annealed silver-plated copper conductor Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket : Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 15 mil ( 0.4 mm) to 19 mil ( 0.5mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/11 SAE AS81044 10 basic colors

86

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight

AWG Size

Conductor Stranding

Min O.D.

Approx LBS/MFT

Max O.D.

In

Mm

In

mm

30

7/38

0.025

0.635

0.029

0.737

0.71

28

7/36

0.028

0.711

0.032

0.813

0.91

26

19/38

0.032

0.813

0.036

0.914

1.30

24

19/36

0.038

0.965

0.042

1.067

2.00

22

19/34

0.045

1.143

0.049

1.245

2.90

20

19/32

0.053

1.346

0.057

1.448

4.40

18

19/30

0.063

1.600

0.067

1.702

6.80

16

19/29

0.069

1.753

0.075

1.905

8.50

14

29/27

0.085

2.159

0.093

2.362

13.40

12

37/28

0.104

2.642

0.112

2.845

20.70

www.caledonian-cables.co.uk

www.addison-cables.com

87


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/12 Applications: MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction

XL-PVDF

Stranded soft annealed tinned copper Irradiation cross-linked extruded Polyalkene

Conductor: Stranded soft annealed tinned copper conductor Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 15 mil ( 0.4 mm) to 21 mil ( 0.5mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/12 SAE AS81044 10 basic colors

88

www.caledonian-cables.co.uk

www.addison-cables.com


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables Dimensions and Weight

AWG Size

Conductor Stranding

Min O.D.

Max O.D.

In

Mm

In

mm

Approx LBS/ MFT

30

7/38

0.025

0.635

0.029

0.737

0.71

28

7/36

0.028

0.711

0.032

0.813

0.96

26

19/38

0.032

0.813

0.036

0.914

1.40

24

19/36

0.038

0.965

0.042

1.067

2.10

22

19/34

0.045

1.143

0.049

1.245

3.10

20

19/32

0.053

1.346

0.057

1.448

4.60

18

19/30

0.063

1.600

0.067

1.702

7.00

16

19/29

0.069

1.753

0.075

1.905

8.90

14

29/27

0.085

2.159

0.093

2.362

13.90

12

37/28

0.104

2.642

0.112

2.845

21.70

www.addison-cables.com

89

www.caledonian-cables.co.uk


Airframe Wire MIL-W-22759/MIL-W-81044

Caledonian Military Cables MIL-W-81044/13 Applications: MIL-W-81044 wire may be used for airframe, avionics, military vehicle, shipboard, missile and other electronic applications, Additionally, the dual layer, lightweight, high temperature wire offers outstanding performance that makes it suitable for many functions where high density cabling and harnessing are required, these wires have excellent resistance to cut-through, abrasion, cold flow, shrink back, notch propagation and common chemicals.

Construction Details The jacket is XL-PVDF

Construction Conductor: Stranded silver-plated high strength copper alloy conductor Insulation: Irradiation cross-linked extruded Polyalkene insulation jacket: Extruded XL Polyvinylidene Fluoride (XL-PVDF) Insulating Material Thickness: 15 mil ( 0.4 mm) to 19 mil ( 0.5mm)

Characteristics Temperature Rating: 150°C Voltage Rating: 600 volts MIL-W-81044/13

XL-PVDF Stranded silver-plated high strength copper alloy

SAE AS81044

Irradiation cross-linked extruded Polyalkene

10 basic colors

Dimensions and Weight AWG Size

90

Conductor Stranding

Min O.D.

Approx LBS/ MFT

Max O.D.

In

Mm

In

mm

30

7/38

0.025

0.635

0.029

0.737

0.71

28

7/36

0.028

0.711

0.032

0.813

0.96

26

19/38

0.032

0.813

0.036

0.914

1.40

24

19/36

0.038

0.965

0.042

1.067

2.10

22

19/34

0.045

1.143

0.049

1.245

3.10

20

19/32

0.053

1.346

0.057

1.448

4.60

www.caledonian-cables.co.uk

www.addison-cables.com


Caledonian Cables Merchant Ind. Centre Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ England United Kingdom Tel: 44- 207- 4195087 Fax: 44- 207- 8319489 Email: sales@caledonian-cables.net sales@caledonian-cables.co.uk uk@addison-cables.com


Turn static files into dynamic content formats.