caledonian coaxial cable

Page 1

n

Coaxial Cables

n o Coaxial Cables s i d d A & www.caledonian-cables.co.uk www.caledonian-cables.co.uk www.caledonian-cables.net www.caledonian-cables.net

www.addison-cables.net

Caledonian Caledonian

www.addison-cables.com

1


Coaxial Cabless

Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. . Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers.

n a ni

o d le

Ca

Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market.

Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.

2

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables Our

& n

Certificate

n o is

d d A

www.addison-cables.net

www.addison-cables.com

3


Coaxial Cabless

Table of Content M17/RG Coaxial-Cable

MIL-C-17F 50 Ohm.............................................................................. 13 RG 8 A/U.................................................................................................. 14 M17/28-RG 58(RG 58) ............................................................................ 15 M17/155-RG 58(RG58 C/U)..................................................................... 16 M17/60-RG 142(RG 142B/U)................................................................... 17 M17/119-RG 174(RG 174A/U)................................................................. 18 M17/74-RG 213(RG 213/U)...................................................................... 19

n a ni

M17/75-RG 214(RG 214/U) . ................................................................... 20 M17/84-RG 223(RG 223/U)...................................................................... 21

M17/111-RG 303(RG 303/U).................................................................... 22

o d le

M17/112-RG 304(RG 304/U).................................................................... 23 M17/127-RG 393(RG 393/U).................................................................... 24

Ca

M17/128-RG 400(RG400/U)..................................................................... 25

MIL-C-17F 75 Ohm......................................................................... 26 M17/2 RG 6(RG 6 A/U)............................................................................. 27 M17/6-RG 11(RG 11 A/U)......................................................................... 28 M17/6-RG 12(RG 12 A/U)........................................................................ 29 M17/29-RG 59(RG 59 B/U)...................................................................... 30 M17/77-RG 216(RG216/U)....................................................................... 31 M17/110-RG 302(RG 302/U)................................................................... 32

RG Type 50 Ohm........................................................................... 33 RG 58 ER................................................................................................. 34 RG 58 CX................................................................................................. 35 RG 174 UR............................................................................................... 36 RG 213 BX............................................................................................... 37 RG 213 TY................................................................................................ 38

4

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables

& n

RG 214 PK................................................................................................ 39 RG 223 FX................................................................................................ 40 RG 223 RK............................................................................................... 41 RG 58 URM(URM 76).............................................................................. 42 RG 58 U43(URM43)................................................................................ 43 RG 213 URM(URM67)............................................................................. 44

RG Type 75 Ohm........................................................................... 45

n o is

RG 6 ....................................................................................................... 46 RG 6/U..................................................................................................... 47

d d A

RG 6/U4................................................................................................... 48

RG 6/U6................................................................................................... 49

RG 6 Quad Shield................................................................................... 50

RG 6 AX................................................................................................... 51

RG 11....................................................................................................... 52 RG 11 AL................................................................................................. 54 RG 11 AX................................................................................................. 55 RG 11 URM = URM 57............................................................................ 56 RG 59 PK................................................................................................ 57 RG 59 BX................................................................................................ 58 RF 59 LL.................................................................................................. 59 RG 59 DS................................................................................................ 60 RG 175 AF............................................................................................... 61

RG Type Low Loss 50 Ohm......................................................... 62 RF 50 LTA................................................................................................ 63 RF 195 LTA.............................................................................................. 64 RF 58 LAP............................................................................................... 65 RF 58 LTA................................................................................................ 66 RF 58 LL.................................................................................................. 67 RF 8 MINI................................................................................................ 68 RF 240 LTA.............................................................................................. 69 RF 8 LAP................................................................................................. 70

www.addison-cables.net

www.addison-cables.com

5


Coaxial Cabless RH 100.................................................................................................... 71 RH 200 INT.............................................................................................. 72 RF 400 LTA.............................................................................................. 73 RF 400 LRP............................................................................................. 74 RG 8 LRP................................................................................................ 75

Broadcast Coaxial 75 Ohm........................................................... 76 RG 59 FX................................................................................................. 77 RF 175 AF............................................................................................... 78 SLS 28810............................................................................................... 79 5 X SL 28810........................................................................................... 80 8 X SL 28810........................................................................................... 81 10 X SL 28810......................................................................................... 82

n a ni

SLS 37885............................................................................................... 83 4 X SL 37885........................................................................................... 84 5 X SL 37885........................................................................................... 85

o d le

SLS 50755............................................................................................... 86 SLS 64955............................................................................................... 87

Ca

Hybrid 75 Ohm............................................................................... 88 Twin RG 6................................................................................................ 89 Twin RG 59.............................................................................................. 90 RG175 + 3 x 0.22mm2............................................................................. 91 RG175 + 2 x 0.22mm2 + 2 x 0.5mm2....................................................... 92 RG175 + 4 x 0.22mm2 + 2 x 0.75mm2..................................................... 93 RG175 + 2 x 0.75mm2+ 10 x 0.5mm2...................................................... 94 RG59 + 2 x 0.5mm2................................................................................. 95 RG59 + 2 x 0.75mm2............................................................................... 96 RG59 + 2 x 1.00mm2............................................................................... 97 RG59 + 2 x 1.5mm2................................................................................. 98 RG59 + 2 x 0.75mm2+ 2 x 0.22mm2........................................................ 99 RG59 + 2 x 1.50mm2+ 2 x 0.25mm2...................................................... 100 RG59 + 2 x 1.50mm2+ 2 x 1.00mm2...................................................... 101 RG59 + 2 x 2.50mm2+ 2 x 0.22mm2...................................................... 102 RG59 + 2 x 0.75mm2+10x 0.50mm2...................................................... 103

6

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables Triaxial Cable Tri-RG178............................................................................................... 105 Tri-RG179............................................................................................... 106 Tri-RG180............................................................................................... 107 Tri-RG316............................................................................................... 108 Tri-RG393............................................................................................... 109

n o is

Tri-RG400................................................................................................110 Tri-RG403................................................................................................111 CTX 41....................................................................................................112

d d A

CTX 44 Flex.............................................................................................113

& n

CTX 47 Flex.............................................................................................114

CTX 64....................................................................................................115

CTX 65 Flex.............................................................................................116

CTX 80 Flex.............................................................................................117

Mininature coaxial Cable 0.81 mm Mini-Coax.................................................................................119 1.13 mm Mini-Coax................................................................................ 120 1.32 mm Mini-Coax................................................................................ 121 1.37 mm Mini-Coax................................................................................ 122 1.48 mm Mini-Coax................................................................................ 123 RG174 Mini-Coax................................................................................... 124 RG178 Mini-Coax................................................................................... 125 RGD178 Mini-Coax................................................................................ 126 RG179 Mini-Coax................................................................................... 127 RG316 Mini-Coax................................................................................... 128 RGD316 Mini-Coax................................................................................ 129 50VMTX.................................................................................................. 130 75VMTX.................................................................................................. 131

www.addison-cables.net

www.addison-cables.com

7


Coaxial Cabless 50Ohm RF Coaxial Cable ALMR100............................................................................................... 133 ALMR195............................................................................................... 134 A LMR200.............................................................................................. 135 A LMR240.............................................................................................. 136 ALMR300............................................................................................... 137 ALMR400............................................................................................... 138 ALMR500............................................................................................... 139 ALMR600............................................................................................... 140 3D-FB.................................................................................................... 141 5D-FB.................................................................................................... 142 7D-FB.................................................................................................... 143

n a ni

8D-FB.................................................................................................... 144 10D-FB................................................................................................... 145 12D-FB................................................................................................... 146

Semi-rigid Coaxial Cable

o d le

Ca

SR034..................................................................................................... 148 SR047/M17............................................................................................. 149 SR086 /M17............................................................................................ 150 SR086-25............................................................................................... 151 SR086-75............................................................................................... 152 SR090-25............................................................................................... 153 SR141..................................................................................................... 154 SR141-25............................................................................................... 155 SR141-35............................................................................................... 156 SR141-75............................................................................................... 157 SR250..................................................................................................... 158 SR250-75............................................................................................... 159

8

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables Semi-flexible Coaxial Cable SF047...................................................................................................... 161 SF047-FEP.............................................................................................. 162 SF086(Flexible RG 405).......................................................................... 163 SF086-FEP.............................................................................................. 165 SF141(Flexible RG 402).......................................................................... 165

n o is

SF141-FEP.............................................................................................. 166 SF250(Flexible RG 401).......................................................................... 167 SF250-FEP.............................................................................................. 168

d d A

50Ohm Wideband Coaxial Cable

& n

RF42(1-5/8″) ......................................................................................... 170 RF32(1-1/4″)........................................................................................... 171

RF22(7/8″).............................................................................................. 172 RF16(5/8″) ............................................................................................. 173 RF12(1/2″) ............................................................................................. 174 RF8(3/8″)................................................................................................ 175 RF6(1/4″)................................................................................................ 176

50Ohm Leaky Coaxial Cable LCX42(1-5/8″)R ...................................................................................... 178 LCX32(1-1/4″)R ...................................................................................... 179 LCX22(7/8″)R.......................................................................................... 180 LCX12(1/2″)R.......................................................................................... 181 LCX42(1-5/8″) L....................................................................................... 182 LCX32(1-1/4″) L....................................................................................... 183 LCX22(7/8″) L.......................................................................................... 184 LCX12(1/2″) L.......................................................................................... 185 LCX8(3/8″) L............................................................................................ 186

www.addison-cables.net

www.addison-cables.com

9


Coaxial Cabless 75Ohm Trunk Cable AQR1125................................................................................................ 188 AQR860.................................................................................................. 189 AQR715.................................................................................................. 190 AQR540.................................................................................................. 191 AQR320.................................................................................................. 192

BT3002 Coaxial Cable BT3002 Single Core............................................................................... 194 BT3002 8 Core....................................................................................... 195

n a ni

BT3002 16 Core..................................................................................... 196

CT Series Coaxial Cable

o d le

CT 100.................................................................................................... 198

Ca

CT 125.................................................................................................... 199 CT 165.................................................................................................... 200

TV Coaxial Cable

19 VATC.................................................................................................. 201 17 VATC.................................................................................................. 202 KX 6........................................................................................................ 203 KX 8........................................................................................................ 204

Ordering Code............................................................................................................206 Insulation & Sheath Material Options...........................................................208 Amouring Options....................................................................................................209 Fire Performance Standard.................................................................................210

10

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables The Introduction of Coaxial Cables A coaxial cable is one that consists of two conductors that share a common axis. The inner conductor is typically a straight wire, either solid or stranded and the outer conductor is typically a shield that might be braided or a foil. Coaxial cable is a cable type used to carry radio signals, video signals, measurement signals and data signals. Coaxial cables exist because we can't run open-wire line near metallic objects (such as ducting) or bury it. We trade signal loss for convenience and flexibility. Coaxial cable consists of an insulated center conductor which is covered with a shield. The signal is carried between the cable shield and the center conductor. This arrangement give quite good shielding against noise from outside cable, keeps the signal well inside the cable and keeps cable characteristics stable.

n o is

d d A

Coaxial cables and systems connected to them are not ideal. There is always some signal radiating from coaxial cable. Hence, the outer conductor also functions as a shield to reduce coupling of the signal into adjacent wiring. More shield coverage means less radiation of energy (but it does not necessarily mean less signal attenuation).

& n

Here is a quick overview of common coaxial cable impedances and their main uses:

50 Ohms:

50 ohms coaxial cable is very widely used with radio transmitter applications. It is used here because it matches nicely to many common transmitter antenna types, can quite easily handle high transmitter power and is traditionally used in this type of applications (transmitters are generally matched to 50 ohms impedance). In addition to this 50 ohm coaxial cable can be found on coaxial Ethernet networks, electronics laboratory interconnection (for example high frequency oscilloscope probe cables) and high frequency digital applications (for example ECL and PECL logic matches nicely to 50 ohms cable). Commonly used 50 Ohm constructions include RG-8 and RG-58.

75 Ohms:

The characteristic impedance 75 ohms is an international standard, based on optimizing the design of long distance coaxial cables. 75 ohms video cable is the coaxial cable type widely used in video, audio and telecommunications applications. Generally all baseband video applications that use coaxial cable (both analogue and digital) are matched for 75 ohm impedance cable. Also RF video signal systems like antenna signal distribution networks in houses and cable TV systems are built from 75 ohms coaxial cable (those applications use very low loss cable types). In audio world digital audio (S/PDIF and coaxial AES/EBU) uses 75 ohms coaxial cable, as well as radio receiver connections at home and in car. In addition to this some telecom applications (for example some E1 links) use 75 ohms coaxial cable. 75 Ohms is the telecommunications standard, because in a dielectric filled line, somewhere around 77 Ohms gives the lowest loss. For 75 Ohm use common cables are RG-6, RG-11 and RG-59.

www.addison-cables.net

www.addison-cables.com

11


Coaxial Cabless Typical coaxial cable constructions are:

RG Coaxial Cables

are used as a connection cable in the high signal sequences of wireless and data communication systems where lower attenuation required, RF and microwave transmission, data transmission and instrumentation control. Some of these cables are based upon MIL-Spec designs and are often referred to by their RG type number.MIL-C-17 is the government specification document used to standardize coaxial cables. Other impedance cables are used for data transmission and instrumentation control. 50 ohms coaxial cables are used in most radio frequency and microwave transmission, local Area Network (LAN), computer and many instrumentation /control applications.

Braided Coaxial Cable

is by far the most common type of closed transmission line because of its flexibility. It is a coaxial cable, meaning that both the signal and the ground conductors are on the same center axis. The outer conductor is made from fine braided wire, hence the name "braided coaxial cable". This type of cable is used in practically all applications requiring complete shielding of the center conductor. The effectiveness of the shielding depends upon the weave of the braid and the number of braid layers. One of the draw-backs of braided cable is that the shielding is not 100% effective, especially at higher frequencies. This is because the braided construction can permit small amounts of short wavelength (high frequency) energy to radiate. Normally this does not present a problem; however, if a higher degree of shielding is required, semirigid coaxial cable is recommended. In some high frequency flexible coaxial cables the outer shield consists if normal braids and an extra aluminium foil shield to give better high frequency shielding. Semi-rigid and Semi-flexible Coaxial Cable uses a solid tubular outer conductor, so that all the RF energy is contained within the cable, are used in wireless communication, broadcast and military equipments for transmission of radio frequency signals. For applications using frequencies higher than 30 GHz a miniature semirigid cable is recommended.

n a ni

o d le

Ca

Leaky Coaxial Cables allow radio, cellular and Wi-Fi communication in areas where free

space electromagnetic radiation typically can’t reach. These cables are used in tunnels, mines, large buildings or building complexes, alongside rail lines and in underground malls to facilitate greater wireless network coverage.

50 Ohm RF Coaxial Cables are transmission coaxial cables for GSM antennas, and the halogen-free cables are suitable for laid on hooks, and pulled through walls or through technical ducts. Trunk Cables

are used used in CATV-community antenna television, CCTV-closed-circuit television, and DBS-direct broadcasting satelite.

BT3002 Coaxial Cables

are mainly used for indoor installation in the transmission equipments for the digital telephone exchange system. Due to their miniature size, they can also be used for other applications where high performance is essential.

12

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables

& n

M17 /RG Coaxial Cables

n o is

MIL-C-17F 50Ohm

d d A

RG 8 A/U

M17/74-RG 213(RG 213/U) M17/28-RG 58(RG 58) M17/155-RG 58(RG58 C/U) M17/119-RG 174(RG 174A/U) M17/75-RG 214(RG 214/U) M17/84-RG 223(RG 223/U) M17/60-RG 142(RG 142B/U) M17/111-RG 303(RG 303/U) M17/112-RG 304(RG 304/U) M17/127-RG 393(RG 393/U) M17/128-RG 400(RG400/U)

www.addison-cables.net

www.addison-cables.com

13


MIL-C-17F Coaxial Cabless RG 8 A/U Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper

7 x 0.72 mm Φ7.25 ± 0.18 mm 192 x 0.2 mm 98% Φ10.4 ± 0.18 mm

PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Test/Operatig Voltage(max) Copper Weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 97 pF/m 66% >2000 Mohm.Km 6.2 Ohm/Km 4.0 Ohm/Km -30 °C - +70 °C 10KV/5KV 84.3 Kg/Km 171.5 Kg/Km 100-900 MHz >55dB

n a i n

o d le

Ca

Plain copper outer conductor Plain copper inner conductor Low density PE dielectric PVC or LSZH sheath

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3

Attenuation (dB/100ift) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

14

>31dB >28dB >27dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables

& n

RG 58/U Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Plain copper Low density PE Tinned copper PVC or LSZH

n o is

Φ0.80 ± 0.025 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 95% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

Nom.53±3 Ohm 94 pF/m 66% >2000 Mohm.Km 35.0 Ohm/Km 16.5 Ohm/Km 5 KV/2 KV -30 °C - +70 °C 18.7 Kg/Km 39.9 Kg/Km 100-900 MHz >55dB PVC or LSZH sheath Tinned copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 9.1 13.1 19.4 28.4 32.2 35.7 44.8 49.0

Attenuation (dB/100ft) 2.77 3.99 5.91 8.66 9.82 10.88 13.66 14.94

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>26dB >25dB >24dB

www.addison-cables.com

15


MIL-C-17F Coaxial Cabless M17/155-RG 58 (RG 58 C/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Tinned copper Low density PE Tinned copper

19 x 0.18 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 95% Φ5.00 ± 0.10 mm

PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 16.5 Ohm/Km 5 KV/2.5 KV -30 °C - +70 °C 18.7 Kg/Km 39.9 Kg/Km 100-900 MHz >55dB

n a i n

o d le

Ca

PVC or LSZH sheath

Tinned copper outer conductor

Tinned copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 10.8 16.0 24.0 37.7 41.3 49.7 64.2 70.0

Attenuation (dB/100ft) 3.29 4.88 7.32 11.49 12.59 15.15 19.57 21.34

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

16

>27dB >23dB >22dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/60-RG142 (RG 142 B/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Outer sheath

Silver plated copper clad steel(SCCS) Solid PTFE Silver plated copper

Φ0.94 mm Φ2.95 ± 0.05mm 112 x 0.13 mm 96% 112 x 0.13 mm 96% Φ4.95 mm

Silver plated copper

n o is FEP

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 95.4 pF/m 70% >2000 Mohm.Km 63.3 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C 47.0 Kg/Km 80.0 Kg/Km 100-900 MHz >60dB FEP sheath Silver copper shield1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2

Attenuation Frequency (MHz) 100 200 400 700 900 1000 2000 3000 5000 8000

Attenuation (dB/100 m) 12.8 17.7 25.9 35.1 40.4 43.0 63.3 79.4 107.0 141.7

Attenuation (dB/100ft) 3.90 5.40 7.90 10.70 12.32 13.11 19.30 24.21 32.62 43.20

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >24dB >22dB

www.addison-cables.com

17


MIL-C-17F Coaxial Cabless M17/119-RG 174 (RG 174 A/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Tinned copper PVC or LSZH

7 x 0.16 mm Φ1.50 ± 0.08 mm 64 x 0.10 mm 88% Φ2.80 ± 0.13 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 290 Ohm/Km 39.0 Ohm/Km 4.5 KV/1.6 KV -30 °C - +70 °C 5.9 Kg/Km 12.5 Kg/Km 100-900 MHz >50dB

n a i n

o d le

Ca

Tinned copper shield Copper covered steel inner conductor Low density PE dielectric PVC or LSZH sheath

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 17.5 25.8 38.2 54.9 63.1 68.6 81.2 87.5

Attenuation (dB/100ft) 5.34 7.87 11.65 16.74 19.24 20.91 24.76 26.68

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

18

>26dB >23dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/74 - RG 213 (RG 213/U) Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

n o is

7 x 0.75 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 4.5 Ohm/Km 10KV/5KV -30 °C - +70 °C 76.9 Kg/Km 163 Kg/Km 100-900 MHz >55dB Plain copper outer conductor Plain copper inner conductor Low density PE dielectric PVC or LSZH sheath

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3

Attenuation (dB/100ift) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >27dB

www.addison-cables.com

19


MIL-C-17F Coaxial Cabless M17/75-RG 214 (RG214/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Low density PE Silver plated copper Silver plated copper PVC or LSZH

7 x 0.75 mm Φ7.25 ± 0.18 mm 144 x 0.16 mm 96% 168 x 0.16 mm 98% Φ10.8 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 3.1 Ohm/Km 10.0 KV/5.0 KV -30 °C - +70 °C 117.7 Kg/Km 205.3 Kg/Km 100-900 MHz >70dB

n a i n

o d le

Ca

PVC or LSZH sheath Silvered copper shield 1 Silvered copper inner conductor Low density PE dielectric Silvered copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.7 7.1 10.4 15.2 17.4 19.2 23.9 26.2

Attenuation (dB/100ft) 1.43 2.16 3.17 4.63 5.30 5.85 7.29 7.99

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

20

>30dB >29dB >27dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/84-RG 223 (RG 223/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Low density PE Silver plated copper Silver plated copper

n o is PVC or LSZH

Φ0.90 ± 0.025 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 98% 112 x 0.13 mm 97% Φ5.40 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 8.0 Ohm/Km 5.0 KV/2.0 KV -30 °C - +70 °C 38.5 Kg/Km 59.9 Kg/Km 100-900 MHz >70dB PVC or LSZH sheath Silver copper shield1 Silver copper inner conductor Low density PE dielectric Silver copper shield2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000 3000 5000 11000

Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5 83.2 109.9 177.5

Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79 25.37 33.51 54.12

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>32dB >28dB >23dB

www.addison-cables.com

21


MIL-C-17F Coaxial Cabless M17/111-RG303 (RG303/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Silver plated copper clad steel (SCCS) PTFE Silver plated copper FEP

Φ0.94 mm Φ2.95 mm 112 x 0.13 mm 95% Φ4.32 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 63.5 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C - Kg/Km 45 Kg/Km 60 dB

n a i n

o d le

Ca

FEP sheath Silvered copper outer conductor Silvered copper clad steel inner conductor Solid PTFE dielectric

Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 1500 2000 3000

Attenuation (dB/100 m) 8.9 12.8 18.4 25.8 36.1 41.0 44.3 52.3 61.4 82.0

Attenuation (dB/100ft) 2.71 3.90 5.61 7.87 11.01 12.50 13.51 15.95 18.72 25.00

Return loss 30-300 MHz 300-600 MHz 600-900 MHz

22

>31dB >26dB >23dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/112-RG304 (RG 304/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper covered steel(SCCS) Solid PTFE Silver plated copper Silver plated copper

n o is FEP

Φ1.50 mm Φ4.75 mm 144 x 0.16 95% 144 x 0.16 95% Φ7.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 96.5 pF/m 70% >2000 Mohm.Km 36.2 Ohm/Km 4.3 Ohm/Km 5.0 KV/3.0 KV -55 °C - +200 °C -Kg/Km 130 Kg/Km 80 dB

FEP sheath Tinned copper shield 1 Silvered copper covered steel inner conductor Low density PE dielectric Tinned copper shield 2

Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 3000 5000 8000

Attenuation (dB/100 m) 5.6 8.5 13.5 18.0 24.9 27.9 30.2 56.8 77.1 114.8

Attenuation (dB/100ft) 1.71 2.59 4.12 5.49 7.59 8.51 9.21 17.32 23.51 35.00

Return loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >27dB >24dB

www.addison-cables.com

23


MIL-C-17F Coaxial Cabless M17/127-RG393 (RG 393/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Solid PTFE Silver plated copper Silver plated copper FEP

7 x 0.79 mm Φ7.25 ± 0.18 mm 144 x 0.16 mm 95% 144 x 0.16 mm 95% Φ9.90 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 4.99Ohm/Km 4.0 Ohm/Km 5.0 KV/2.5 KV -55 °C - +200 °C - Kg/Km 240 Kg/Km 80dB

n a i n

o d le

Ca

FEP sheath Silver copper shield 1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2

Attenuation Frequency (MHz) 100 200 400 900 1000 2000 3000 5000

Attenuation (dB/100 m) 6.6 9.7 14.3 22.1 24.0 34.4 47.0 65.0

Attenuation (dB/100ft) 2.01 2.96 4.36 6.74 7.32 10.49 14.33 19.82

Return loss 30-300 MHz 300-600 MHz 600-900 MHz

24

>30dB >28dB >23dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/128-RG400 (RG 400/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Solid PTFE Silver plated copper Silver plated copper

n o is FEP

19 x 0.20 mm Φ2.95 ± 0.05 mm 112 x 0.13 mm 95% 112 x 0.13 mm 94% Φ4.90 ± 0.13 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 12.6 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C 46 Kg/Km 64 Kg/Km 80 dB

FEP sheath Silver copper shield1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2

Attenuation Frequency (MHz) 50 100 200 400 900 1000 2000 3000 5000 8000

Attenuation (dB/100 m) 8.5 12.5 17.7 25.9 40.4 43.0 63.3 79.4 107.0 141.7

Attenuation (dB/100ft) 2.59 3.81 5.40 7.90 12.32 13.11 19.30 24.21 32.62 43.20

Return loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >25dB >22dB

www.addison-cables.com

25


MIL-C-17F Coaxial Cabless

M17 /RG Coaxial Cables MIL-C-17F 75Ohm

n a i n

M17/2 RG 6(RG 6 A/U)

o d le

M17/6-RG 11(RG 11 A/U)

M17/6-RG 12(RG 12 A/U)

Ca

M17/29-RG 59(RG 59 B/U) M17/77-RG 216(RG216/U)

M17/110-RG 302(RG302/U)

26

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/2-RG 6 (RG 6 A/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Silver plated copper Plain copper

n o is PVC or LSZH

Φ0.72 ± 0.025 mm Φ4.70 ± 0.10 mm 144 x 0.16 mm 97% 144 x 0.16 mm 95% Φ8.50 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 106 Ohm/Km 5.0 Ohm/Km 5.0 KV/3.0 KV -30 °C - +70 °C 46 Kg/Km 64.6 Kg/Km >70 dB

PVC or LSZH sheath Silver copper shield1 Copperweld inner conductor Low density PE dielectric Plain copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 5.8 8.5 12.5 18.0 20.3 22.6 27.5 30.4

Attenuation (dB/100ft) 1.77 2.59 3.81 5.49 6.19 6.89 8.38 9.27

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >24dB >22dB

www.addison-cables.com

27


MIL-C-17F Coaxial Cabless M17/6-RG 11 (RG11A/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Tinned copper Low density PE Plain copper

7 x 0.40 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm

PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km 8.0 KV/5.0 KV -30 °C - +70 °C 57 Kg/Km 145.2 Kg/Km >55 dB

n a i n

o d le

Ca

Plain copper shield Tinned copper inner conductor Low density PE dielectric PVC or LSZH sheath

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 20.1 23.4

Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.13 7.13

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

28

>30dB >27dB >25dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/6-RG 12 (RG12A/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Inner sheath Outer conductor(shield 2) Shield coverage Outer sheath

Tinned copper Low density PE Plain copper PVC Zinc-plated steel wire(FE-ZN)

n o is

d d A

PVC or LSZH

7 x 0.40 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm 144 x 0.24 mm 85% Φ14.30 ± 0.20 mm

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km 8.0 KV/5.0 KV -30 °C - +70 °C 57 Kg/Km 298.5 Kg/Km >70 dB

FE-ZN shield 2 Low density PE dielectric Tinned copper inner conductor Plain copper shield1 PVC inner sheath PVC or LSZH outer sheath

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 21.1 23.4

Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.43 7.13

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >27dB >25dB

www.addison-cables.com

29


MIL-C-17F Coaxial Cabless M17/29-RG 59 (RG 59 B/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH

Φ0.58 ± 0.03 mm Φ3.70 ± 0.10 mm 120 x 0.15 mm 95% Φ6.20 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 9.0 Ohm/Km 5.0 KV/3.5 KV -30 °C - +70 °C 22.4 Kg/Km 55.8 Kg/Km >55 dB

n a i n

o d le

Ca

PVC or LSZH sheath Plain copper shield Copper clad steel inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

30

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


MIL-C-17F Coaxial Cables M17/77-RG 216 Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Outer sheath

Tinned copper Low density PE Plain copper Plain copper

n o is PVC or LSZH

7 x 0.40 mm Φ7.25 ± 0.18 mm 216 x 0.16 mm 97% 192 x 0.16 mm 96% Φ10.8 ± 0.18 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 3.3 Ohm/Km -30 °C - +70 °C 97.3 Kg/Km 187.0 Kg/Km >70 dB

Plain copper shield 2 Plain copper shield1 Tinned copper inner conductor Low density PE dielectric

Attenuation

PVC or LSZH sheath

Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 22.1 23.4

Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.74 7.13

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >27dB >25dB

www.addison-cables.com

31


MIL-C-17F Coaxial Cabless M17/110-RG302 (RG302/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Silver plated copper clad steel (SCCS) PTFE Silver plated copper (0.13mm) FEP

Φ064 mm Φ3.71 mm Φ4.21 mm 90% Φ5.13 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 63.7 pF/m 70% >2000 Mohm.Km 147.5 Ohm/Km 47.5 Ohm/Km 3.5 KV/1.9 KV -55 °C - +200 °C - Kg/Km 56 Kg/Km <130 dB

n a i n

o d le

Ca

FEP sheath Silvered copper outer conductor Silvered copper clad steel inner conductor Solid PTFE dielectric

Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 1500 2000 3000

32

Attenuation (dB/100 m) 6.2 12.1 17.7 24.9 36.1 34.4 38.7 44.1 52.0 70.5

www.caledonian-cables.co.uk

Attenuation (dB/100ft) 1.89 3.69 5.40 7.59 11.01 10.49 11.80 13.45 15.85 21.49

www.caledonian-cables.net


MIL-C-17F Coaxial Cables

& n

M17 /RG Coaxial Cables

n o is

RG Type 50Ohm

d d A

RG 58 ER RG 58 CX RG 174 UR RG 213 BX RG 213 TY RG 214 PK RG 223 FX RG 223 RK RG 58 URM(URM 76) RG 58 U43(URM43) RG 213 URM(URM67)

www.addison-cables.net

www.addison-cables.com

33


RG Type 50 Ohm Coaxial Cabless RG 58 ER Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

16 x 0.18 mm Φ2.85 ± 0.10 mm 80 x 0.12 mm 79% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 44 Ohm/Km 24 Ohm/Km -30 °C - +70 °C 12.4 Kg/Km 34.4 Kg/Km >50 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 9.8 14.1 20.6 30.4 34.8 38.7 47.9 52.8

Attenuation (dB/100 ft) 2.99 4.30 6.28 9.27 10.61 11.80 14.60 16.10

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

34

>26dB >25dB >22dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 50 Ohm Coaxial Cables RG 58 CX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Tinned copper Low density PE Tinned copper PVC or LSZH

n o is

19 x 0.18 mm Φ2.95 ± 0.10 mm 140 x 0.10 mm 93% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristic

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 17 Ohm/Km -30 °C - +70 °C 14.9 Kg/Km 37.1 Kg/Km >55 dB

PVC or LSZH sheath Tinned copper shield Tinned copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 9.7 13.9 20.4 30 34.2 37.9 46.9 51.8

Attenuation (dB/100 ft) 2.96 4.24 6.22 9.15 10.43 11.55 14.30 15.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>27dB >23dB >22dB

www.addison-cables.com

35


RG Type 50 Ohm Coaxial Cabless RG 174 UR Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.16 mm Φ1.50 ± 0.08 mm 64 x 0.10 mm 88% Φ2.80 ± 0.13 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 122 Ohm/Km 39 Ohm/Km -30 °C - +70 °C 6.1 Kg/Km 12.7 Kg/Km >50 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 17.7 26.0 38.5 55.3 63.6 69.2 81.9 88.3

Attenuation (dB/100 ft) 5.40 7.93 11.74 16.86 19.39 21.10 24.97 26.92

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

36

>26dB >23dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 50 Ohm Coaxial Cables RG 213 BX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

n o is

7 x 0.75 mm Φ6.50 ± 0.15 mm 168 x 0.15 mm 91% Φ9.50 ± 0.18 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6 Ohm/Km 7 Ohm/Km -30 °C - +70 °C 59.6 Kg/Km 135.1 Kg/Km >55 dB

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.8 7.2 10.5 15.4 17.6 19.5 24.2 26.5

Attenuation (dB/100 ft) 1.46 2.20 3.20 4.70 5.37 5.95 7.38 8.08

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>27dB >24dB >23dB

www.addison-cables.com

37


RG Type 50 Ohm Coaxial Cabless RG 213 TY Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.75 mm Φ7.25 ± 0.08 mm 240 x 0.13 mm 93% Φ10.3 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 5.0 Ohm/Km -30 °C - +70 °C 59.9 Kg/Km 149.7 Kg/Km >55 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 4.5 6.8 10.0 14.5 16.4 18.1 22.5 24.7

Attenuation (dB/100 ft) 1.37 2.07 3.05 4.42 5.00 5.52 6.86 7.53

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

38

>31dB >28dB >27dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 50 Ohm Coaxial Cables RG 214 PK Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Low density PE Silver plated copper

7 x 0.75 mm Φ7.25 ± 0.18 mm 168 x 0.13 mm 79% 168 x 0.13 mm 76% Φ10.8 ± 0.18 mm

Silver plated copper

n o is PVC or LSZH

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 3.8 Ohm/Km -30 °C - +70 °C 75.2 Kg/Km 167.6 Kg/Km >70 dB

PVC or LSZH sheath Silvered copper shield 1 Silvered copper inner conductor Low density PE dielectric Silvered copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.8 7.2 10.5 15.4 17.6 19.5 24.2 26.5

Attenuation (dB/100 ft) 1.46 2.20 3.20 4.70 5.37 5.95 7.38 8.08

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >29dB >27dB

www.addison-cables.com

39


RG Type 50 Ohm Coaxial Cabless RG 223 FX Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Tinned copper Low density PE Silver plated copper

19 x 0.18 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 98% 112 x 0.13 mm 97% Φ5.40 ± 0.10 mm

Silver plated copper PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 8 Ohm/Km -30 °C - +70 °C 32.7 Kg/Km 54.2 Kg/Km >70 dB

n a ni

o d

e l a

C

PVC or LSZH sheath Silvered copper shield 1 Tinned copper inner conductor Low density PE dielectric Silvered copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 9.7 13.9 20.4 30.0 34.2 37.9 46.9 51.8

Attenuation (dB/100 ft) 2.96 4.24 6.22 9.15 10.43 11.55 14.30 15.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

40

>27dB >23dB >22dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 50 Ohm Coaxial Cables RG 223 RK Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Silver plated copper Low density PE Tinned copper Tinned copper

n o is PVC or LSZH

0.9 mm Φ2.95 ± 0.10 mm 112 x 0.10 mm 85% 112 x 0.10 mm 80% Φ5.40 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 11 Ohm/Km -30 °C - +70 °C 22.7 Kg/Km 46.3 Kg/Km >70 dB

PVC or LSZH sheath Tinned copper shield 1 Silvered copper inner conductor Low density PE dielectric Tinned copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5

Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>32dB >28dB >23dB

www.addison-cables.com

41


RG Type 50 Ohm Coaxial Cabless RG 58 URM (URM76) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.32 mm Φ2.95 ± 0.10 mm 96 x 0.12 mm 86% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 32 Ohm/Km 17.5 Ohm/Km -30 °C - +70 °C 15.4 Kg/Km 36.9 Kg/Km >55 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 9.4 13.5 19.9 29.2 33.2 36.8 45.6 50.4

Attenuation (dB/100ft) 2.87 4.12 6.07 8.90 10.12 11.22 13.90 15.37

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

42

>28dB >24dB >22dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 50 Ohm Coaxial Cables RG 58 U43(URM 43) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

n o is

0.90 mm Φ2.95 ± 0.10 mm 96 x 0.15 mm 95% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 16.5 Ohm/Km -30 °C - +70 °C 22.1 Kg/Km 42.5 Kg/Km >55 dB

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5

Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>32dB >28dB >23dB

www.addison-cables.com

43


RG Type 50 Ohm Coaxial Cabless RG 213 URM (URM 67) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.75 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 98% Φ10.3 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 4.0 Ohm/Km -30 °C - +70 °C 79.4 Kg/Km 165.5 Kg/Km >55 dB

n a ni

o d

e l a

C

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3

Attenuation (dB/100ft) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

44

>31dB >28dB >27dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

RG Type 50 Ohm Coaxial Cables

M17 /RG Coaxial Cables RG Type 75Ohm

n o is

A &

dd

RG 6

RG 6/U RG 6/U4 RG 6/U6 RG 6 Quad Shield RG 6 AX RG 11 RG 11 AL RG 11 AX RG 11 URM = URM 57 RG 59 PK RG 59 BX RF 59 LL RG 59 DS RG 175 AF

www.addison-cables.net

www.addison-cables.com

45


RG Type 75 Ohm Coaxial Cabless RG 6 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Copper clad steel (CCS) Foam PE Bonded Aluminium/Polyester Aluminium PVC or LSZH

Φ1.02 mm Φ4.57 ± 0.20 mm 100% 96 x 0.12 mm 82% Φ6.91 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 54 pF/m 83% >5000 Mohm.Km 21.7 Ohm/Km 24.1Ohm/Km -30 °C - +70 °C 45 Kg/Km

n a ni

o d

e l a

C

PVC or LSZH sheath Bonded AL/Polyester tape Copper clad steel inner conductor Foamed PE dielectric AL outer conductor

Attenuation Frequency(MHz) 50 100 200 400 700 900 1000 1350 1750 2150 2500

46

Attenuation (dB/100 m) 5.0 6.7 9.5 14.1 19.9 23.2 24.8 29.9 35.1 37.9 39.0

www.caledonian-cables.co.uk

Attenuation (dB/100ft) 1.5 2.0 2.9 4.2 6.0 7.0 7.5 9.0 10.5 11.4 11.7

www.caledonian-cables.net


n

RG Type 75 Ohm Coaxial Cables RG 6/U Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Bare copper Foam PE Aluminium foil

Φ1.02 mm Φ4.57 ± 0.20 mm 100% 96 x 0.12 mm 70% Φ7.00 ± 0.20 mm

Aluminium

n o is

dd

PVC or LSZH

Electrical & Mechanical Characteristics

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 54 pF/m 82% >5000 Mohm.Km 23.1 Ohm/Km 31Ohm/Km -30 °C - +70 °C 43 Kg/Km

PVC or LSZH sheath Bonded AL/Polyester tape Bare copper inner conductor Foamed PE dielectric AL outer conductor

Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2050 2400

Attenuation (dB/100 m) 5.0 6.4 9.2 14.5 15.9 17.7 21.9 24.9 29.0 33.1 36.4

www.addison-cables.net

Attenuation (dB/100ft) 1.5 1.96 2.8 4.4 4.9 5.4 6.7 7.6 8.8 10.1 11.1

www.addison-cables.com

47


RG Type 75 Ohm Coaxial Cabless RG 6/U4 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Bare copper Foam PE Aluminium foil

Φ1.02 mm Φ4.60 ± 0.20 mm 100% 64 x 0.12 mm 60% Φ6.80 ± 0.20 mm

Tinned copper PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 53 pF/m 83% >5000 Mohm.Km 23.1 Ohm/Km 28Ohm/Km -30 °C - +70 °C 46 Kg/Km

o d

e l a

C

n a ni

PVC or LSZH sheath Bonded AL/Polyester tape Bare copper inner conductor Foamed PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400

48

Attenuation (dB/100 m) 4.5 6.2 8.9 15.1 16.8 19.0 21.5 24.9 28.3 31.1 33.3

www.caledonian-cables.co.uk

Attenuation (dB/100ft) 1.4 1.9 2.7 4.6 5.1 5.8 6.6 7.6 8.6 9.5 10.1

www.caledonian-cables.net


n

RG Type 75 Ohm Coaxial Cables RG 6/U6 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Bare copper Foam PE Copper foil Copper

n o is

dd

PVC or LSZH

Φ1.02 mm Φ4.60 ± 0.20 mm 100% 64 x 0.12 mm 60% Φ6.80 ± 0.20 mm

Electrical & Mechanical Characteristics

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 54 pF/m 83% >5000 Mohm.Km 21.7 Ohm/Km 24.1Ohm/Km -30 °C - +70 °C 50 Kg/Km

PVC or LSZH sheath Copper foil tape Bare copper inner conductor Foamed PE dielectric Copper outer conductor

Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400

Attenuation (dB/100 m) 4.4 6.1 9.2 14.8 16.0 19.0 20.5 23.7 27.1 29.9 31.7

www.addison-cables.net

Attenuation (dB/100ft) 1.3 1.9 2.8 4.5 4.9 5.8 6.2 7.2 8.3 9.1 9.7

www.addison-cables.com

49


RG Type 75 Ohm Coaxial Cabless RG 6 Quad Shield Construction Inner conductor Dielectric Tape shield(shield 1) Braid shield(shield 2) Shield coverage Tape shield(shield 3) Braid shieldr(shield 4) Shield coverage Sheath

Copper clad steel(CCS) Foam PE Al-maylar Aluminium Al-maylar Aluminium PVC or LSZH

Φ1.02 mm Φ4.60 ± 0.20 mm ≥25% 80 x 0.12mm ≥60% ≥25% 64 x 0.12 mm ≥40% Φ7.55 ± 0.20 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 54 pF/m 82% >5000 Mohm.Km < 24.1 Ohm/Km -30 °C - +70 °C 59.8 Kg/Km

n a ni

o d

e l a

C

PVC or LSZH sheath Al-maylar shield 3

Al-maylar shield 1 Copper clad steel inner conductor Foamed PE dielectric AL braid shield 2 AL braid shield 4

Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400 3000

50

Attenuation (dB/100 m) 4.8 6.7 9.3 15.0 16.9 19.4 21.6 24.2 28.0 31.5 32.8 37.9

www.caledonian-cables.co.uk

Attenuation (dB/100ft) 1.5 2.0 2.8 4.6 5.1 5.9 6.6 7.4 8.4 9.6 10.0 11.5

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables RG 6 AX Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Silver plated copper Plain copper

n o is PVC or LSZH

0.72 mm Φ4.70 ± 0.10 mm 168 x 0.13 mm 97% 168 x 0.13 mm 95% Φ8.50 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 106 Ohm/Km 5 Ohm/Km -30 °C - +70 °C 50.5 Kg/Km 112.4 Kg/Km >70 dB

PVC or LSZH sheath Silvered copper shield 1 Copper clad steel inner conductor Low density PE dielectric Plain copper shield 2

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 5.8 8.5 12.5 18.0 20.3 22.6 27.5 30.4

Attenuation (dB/100 m) 1.77 2.59 3.81 5.49 6.19 6.89 8.38 9.27

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >24dB >22dB

www.addison-cables.com

51


RG Type 75 Ohm Coaxial Cabless RG 11 Construction Inner conductor Dielectric Tape shield Outer conductor (shield) Shield coverage Sheath Messenger(optional)

Copper clad steel(CCS) Low density PE Aluminum foil Aluminum wire PVC or LSZH Galvanized steel

1.63 mm Φ7.2 ± 0.2 mm 100% 96 x 0.12 mm 60% Φ10.3 ± 0.18 mm 1.83mm / 2.77mm

* Tri-shield and Quad-shield are both optional ,so is the messenger Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

Attenuation Frequency(MHz) 50 100 250 300 350 400 450 500 550 600 750 860 1000 1450 2050

52

75±5 Ohm 53 pF/m 66% >2000 Mohm.Km 13.5 Ohm/Km 24.1 Ohm/Km -30 °C - +70 °C 116.4 -140.4Kg/Km

n a ni

o d

e l a

C

Attenuation (dB/100 m) 3.1 4.2 6.8 7.5 7.9 8.5 9.1 9.5 10.1 10.5 12.1 13.2 14.3 18.6 23.0

www.caledonian-cables.co.uk

Attenuation (dB/100ft) 0.95 1.28 2.07 2.29 2.41 2.59 2.77 2.90 3.08 3.20 3.69 4.02 4.36 5.67 7.01

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables

& n

PVC or LSZH sheath AL foil shield Copper clad steel inner conductor Foamed PE dielectric Tinned copper outer conductor

n o is

d d A

PVC or LSZH sheath Al foil shield 3 Al foil shield 1 Copper clad steel inner conductor Low density PE dielectric AL braid shield 2 AL braid shield 4

PVC or LSZH sheath AL foil shield Copper clad steel inner conductor Foamed PE dielectric Tinned copper outer conductor Galvanized steel messenger

www.addison-cables.net

www.addison-cables.com

53


RG Type 75 Ohm Coaxial Cabless RG 11 AL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.40 mm Φ7.25 ± 0.18 mm 112 x 0.15 mm 64% Φ10.3 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 10 Ohm/Km -30 °C - +70 °C 27.8 Kg/Km 118.2 Kg/Km >45 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 4.4 6.4 9.7 14.3 16.1 17.9 22.0 24.4

Attenuation (dB/100ft) 1.34 1.95 2.96 4.36 4.91 5.46 6.71 7.44

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

54

>30dB >27dB >25dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables RG 11 AX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

7 x 0.40 mm Φ7.25 ± 0.18 mm 240 x 0.15 mm 97% Φ10.3 ± 0.18 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km -30 °C - +70 °C 49.8 Kg/Km 140.2 Kg/Km >55 dB

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.2 6.2 9.2 13.8 15.5 17.1 21.1 23.4

Attenuation (dB/100ft) 1.28 1.89 2.80 4.21 4.73 5.21 6.43 7.13

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >27dB >25dB

www.addison-cables.com

55


RG Type 75 Ohm Coaxial Cabless RG 11URM (URM 57) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

1.15 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 16.6 Ohm/Km 4.5 Ohm/Km -30 °C - +70 °C 58.3 Kg/Km 146.7 Kg/Km >55 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 3.8 5.5 8.2 12.0 13.6 15.0 18.8 20.7

Attenuation (dB/100ft) 1.16 1.68 2.50 3.66 4.15 4.57 5.73 6.31

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

56

>30dB >27dB >25dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables RG 59 PK Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH

0.58 mm Φ3.70 ± 0.10 mm 120 x 0.10 mm 77% Φ6.15 ± 0.10 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 19.5 Ohm/Km -30 °C - +70 °C 11.1 Kg/Km 45.7 Kg/Km >50 dB

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.6 11.1 16.2 23.2 26.2 29.3 35.5 38.7

Attenuation (dB/100ft) 2.32 3.38 4.94 7.07 7.99 8.93 10.82 11.80

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >24dB

www.addison-cables.com

57


RG Type 75 Ohm Coaxial Cabless RG 59 BX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11.0 Ohm/Km -30 °C - +70 °C 15.5 Kg/Km 50.9 Kg/Km >55 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation

n a ni

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.1

Attenuation (dB/100ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.62

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

58

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables RF 59 LL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Foam PE Plain copper PVC or LSZH

7 x 0.25 mm Φ3.70 ± 0.10 mm 120 x 0.15 mm 95% Φ6.15 ± 0.10 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 49 Ohm/Km 9 Ohm/Km -30 °C - +70 °C 23.8 Kg/Km 53.0 Kg/Km >55 dB

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.1 10.1 14.0 20.2 23.6 26.2 32.2 34.8

Attenuation (dB/100ft) 2.16 3.08 4.27 6.16 7.20 7.99 9.82 10.61

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>25dB >24dB >20dB

www.addison-cables.com

59


RG Type 75 Ohm Coaxial Cabless RG 59 DS Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Low densty PE Plain copper

0.6 mm Φ3.70 ± 0.10 mm 120 x 0.12 mm 86% 120 x 0.12 mm 86% Φ6.10 ± 0.10 mm

Tinned copper PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 62 Ohm/Km 8.5 Ohm/Km -25 °C - +80 °C 29.9 Kg/Km 59.8 Kg/Km >70 dB

C

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d

e l a

PVC or LSZH sheath Plain copper shield 1 Plain copper inner conductor Low density PE dielectric Tinned copper shield 2

Attenuation

n a ni

Attenuation (dB/100 m) 7.2 10.5 15.5 22.3 25.1 28.0 33.9 37.0

Attenuation (dB/100ft) 2.20 3.20 4.73 6.80 7.65 8.54 10.34 11.28

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

60

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type 75 Ohm Coaxial Cables RG 175 AF Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Foam PE Silver plated copper PVC or LSZH

9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25 °C - +80 °C 5.85 Kg/Km 12.95 Kg/Km >50 dB

PVC or LSZH sheath Silvered copper shield Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0

Attenuation (dB/100ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>20dB >20dB >20dB

www.addison-cables.com

61


RG Type 75 Ohm Coaxial Cabless

M17 /RG Coaxial Cables RG Type Low Loss 50Ohm RF 50 LTA RF 195 LTA

n a i n o d e l Ca

RF 58 LAP RF 58 LTA RF 58 LL

RF 8 MINI

RF 240 LTA RF 8 LAP RH 100

RH 200 INT RF 400 LTA RF 400 LRP RG 8 LRP

62 62

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RF 50 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Tinned copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o s i d d A PVC or LSZH

7 x 0.25 mm Φ2.00 ± 0.10 mm 100% 48 x 0.12 mm 64% Φ3.60 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 95 pF/m 75% >5000 Mohm.Km 20.5 Ohm/Km 32.5 Ohm/Km -30 °C - +70 °C 8.2 Kg/Km 18.3 Kg/Km >75 dB

PVC or LSZH sheath AL + polyester + AL tape Tinned copper inner conductor Foamed PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 13.0 17.3 35.0 43.3 52.7 57.2 76.7 94.0

Attenuation (dB/100ft) 3.96 5.27 10.67 13.20 16.07 17.44 23.38 28.66

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>24dB >21dB >15dB

www.addison-cables.com

63


RG Type Low Loss Coaxial Cabless RF 195 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC or LSZH

0.95 mm Φ2.80 ± 0.10 mm 100% 96 x 0.12 mm 85% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 25.2 Ohm/Km 18.5 Ohm/Km -30 °C - +70 °C 16.6 Kg/Km 36.6 Kg/Km >80 dB

n a i n

o d le

Ca

PVC or LSZH sheath AL + polyester + AL tape Plain copper inner conductor Foamed PE dielectric

Attenuation

Tinned copper outer conductor

Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 8.5 11.3 22.9 28.7 34.5 37.5 52.2 64.0

Attenuation (dB/100ft) 2.59 3.45 6.98 8.75 10.52 11.43 15.91 19.51

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

64

>28dB >24dB >19dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RF 58 LAP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Tinned copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is PVC or LSZH

7 x 0.40 mm Φ3.10 ± 0.10 mm 100% 96 x 0.10 mm 72% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 20.5 Ohm/Km 20 Ohm/Km -30 °C - +70 °C 15.3 Kg/Km 33.9 Kg/Km >80 dB

PVC or LSZH sheath AL + polyester + AL tape Tinned copper inner conductor Foamed PE dielectric

Attenuation

Tinned copper outer conductor

Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 9.6 12.8 25.9 32.1 39.0 42.4 59.0 72.3

Attenuation (dB/100ft) 2.93 3.90 7.90 9.79 11.89 12.93 17.99 22.04

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >24dB >22dB

www.addison-cables.com

65


RG Type Low Loss Coaxial Cabless RF 58 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper + black PE Gas injected foam PE + Carbon black PE Aluminium + polyester + Aluminium tape Tinned copper PVC or LSZH

1.00 mm Φ2.95 ± 0.10 mm 100% 64 x 0.15 mm 73% Φ5.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 20.5 Ohm/Km -30 °C - +70 °C 17.8 Kg/Km 35.4 Kg/Km >80 dB

n a i n

o d le

Ca

PVC or LSZH sheath AL + polyester + AL tape

Plain copper+black PE inner conductor Gas injected foam PE+black PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 7.3 9.8 19.7 24.9 30.1 32.7 45.8 55.8

Attenuation (dB/100ft) 2.23 2.99 6.01 7.59 9.18 9.97 13.96 17.01

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

66

>30dB >26dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RF 58 LL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Foam PE Plain copper PVC or LSZH

7 x 0.50 mm Φ3.80 ± 0.10 mm 144 x 0.12 mm 94% Φ5.40 ± 0.10 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 14 Ohm/Km 11 Ohm/Km -30 °C - +70 °C 28.0 Kg/Km 45.9 Kg/Km >55 dB

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Foamed PE dielectric

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 7.0 10.2 21.2 26.3 32.2 35.1 48.0 58.2

Attenuation (dB/100ft) 2.13 3.11 6.46 8.02 9.82 10.70 14.63 17.74

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >27dB >22dB

www.addison-cables.com

67


RG Type Low Loss Coaxial Cabless RF 8 MINI Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath

Plain copper Foam PE Plain copper

19 x 0.28 mm Φ3.90 ± 0.15 mm 128 x 0.12 mm 88% Φ6.10 ± 0.10 mm

PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 14 Ohm/Km -25 °C - +80 °C 25.2 Kg/Km 53.7 Kg/Km >55 dB

n a i n

o d le

Ca

PVC or LSZH sheath Plain copper shield Plain copper inner conductor Foamed PE dielectric

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 7.2 10.5 22.2 27.6 33.9 37.0 51.6 64.5

Attenuation (dB/100ft) 2.20 3.20 6.77 8.41 10.34 11.28 15.73 19.66

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

68

>26dB >25dB >23dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

RG Type Low Loss Coaxial Cables RF 240 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is PVC or LSZH

1.40 mm Φ3.80 ± 0.10 mm 100% 112 x 0.12 mm 80% Φ6.10 ± 0.10 mm

Electrical & Mechanical Characteristics

dd

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 11.5 Ohm/Km 14.5 Ohm/Km -30 °C - +70 °C 25.9 Kg/Km 52.6 Kg/Km >90 dB

PVC or LSZH sheath AL+polyester +ALtape Plain copper inner conductor Foamed PE dielectric

Attenuation

Tinned copper outer conductor

Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 5.7 7.8 16.2 20.0 24.2 26.0 36.0 43.1

Attenuation (dB/100ft) 1.74 2.38 4.94 6.10 7.38 7.93 10.98 13.14

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>28dB >24dB >19dB

www.addison-cables.com

69


RG Type Low Loss Coaxial Cabless RF 8 LAP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester tape Tinned copper PVC or LSZH

19 x 0.28 mm Φ3.90 ± 0.15 mm 100% 128 x 0.10 mm 80% Φ6.10 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 19 Ohm/Km -30 °C - +70 °C 20.8 Kg/Km 48.1 Kg/Km >80 dB

n a i n

o d le

Ca

PVC or LSZH sheath AL+polyester +ALtape Plain copper inner conductor Foamed PE dielectric

Attenuation

Tinned copper outer conductor

Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 7.3 9.8 19.7 24.9 30.1 32.9 45.8 55.8

Attenuation (dB/100ft) 2.23 2.99 6.01 7.59 9.18 10.03 13.96 17.01

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

70

>26dB >25dB >23dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RH 100 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Aired PE Copper + polyester tape Plain copper

n o is PVC or LSZH

2.5 mm Φ6.90 ± 0.20 mm 100% 96 x 0.12 mm 50% Φ9.70 ± 0.20 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.7 Ohm/Km 12.5 Ohm/Km -30 °C - +70 °C 61.0 Kg/Km 128.4 Kg/Km >75 dB

PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor Aired PE dielectric Plain copper outer conductor

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2

Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>25dB >22dB >18dB

www.addison-cables.com

71


RG Type Low Loss Coaxial Cabless RH 200 INT Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Tape Sheath

Plain copper Aired PE Copper + polyester tape Plain copper Non-migrating tape PVC or LSZH

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.7 Ohm/Km 5.5 Ohm/Km -40 °C - +75 °C 88.5 Kg/Km 148 Kg/Km >85 dB

100% 192 x 0.15 mm 96% h.27mm Φ10.30 ± 0.20 mm Copper + polyester tape Non-migrating tape Plain copper inner conductor Aired PE dielectric Plain copper outer conductor PVC or LSZH outer sheath

Electrical & Mechanical Characteristics

2.5 mm Φ6.90 ± 0.20 mm

n a i n

o d le

Ca

Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2

Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

72

>25dB >22dB >18dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RF 400 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Tape Sheath

Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.2 Ohm/Km 7.5 Ohm/Km -40 °C - +75 °C 71.0 Kg/Km 122.1 Kg/Km >85 dB

100% 128 x 0.15 mm 70% h.27mm Φ10.30 ± 0.18 mm

Copper + polyester tape Non-migrating tape Plain copper inner conductor Gas injected foam PE dielectric Tinned copper outer conductor PVC or LSZH outer sheath

d d A

Non-migrating tape PVC or LSZH

2.62 mm Φ7.20 ± 0.10 mm

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2

Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>29dB >26dB >24dB

www.addison-cables.com

73


RG Type Low Loss Coaxial Cabless RF 400 LRP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Gas injected foam PE Copper + polyester tape Plain copper PVC or LSZH

2.62 mm Φ7.20 ± 0.10 mm 100% 96 x 0.15 mm 56% Φ10.30 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.2 Ohm/Km 12.7 Ohm/Km -30 °C - +70 °C 71.3Kg/Km 137.7 Kg/Km >80 dB

n a i n

o d le

Ca

PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor

Gas injected foam PE dielectric Plain copper outer conductor

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2

Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

74

>29dB >26dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


RG Type Low Loss Coaxial Cables RG 8 LRP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Low density PE Copper + polyester tape Plain copper

n o is PVC or LSZH

7 x 0.75 mm Φ7.25 ± 0.18 mm 100% 128 x 0.10 mm 57% Φ10.40 ± 0.18 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6 Ohm/Km 13 Ohm/Km -30 °C - +70 °C 45.3 Kg/Km 137.9 Kg/Km >80 dB

PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor Low density PE dielectric Plain copper outer conductor

Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400

Attenuation (dB/100 m) 3.7 5.4 11.7 14.6 18.1 19.6 28.8 35.1

Attenuation (dB/100ft) 1.13 1.65 3.57 4.45 5.52 5.98 8.78 10.70

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >27dB >23dB

www.addison-cables.com

75


RG TypeBroadcast Low Loss Coaxial Coaxial Cabless Cabless Broadcast 75 Ohm RG 59 DS

M17 /RG Coaxial Cables Broadcast 75Ohm

Construction

 Plain copper inner conductor 0.60 mm  Low density polyethylene dielectric Φ3.70 ± 0.10 mm  Plain copper Outer conductor (shield 1)20 x 0.12 mm

RG 59 FX

 Shield coverage 86%

n a i n

x 0.12  Tinned copper Outer conductor (shield RF1)20 175 AF mm  Shield coverage 86%

o d le

SLS 28810 sheath Φ6.10 ± 0.10 mm  Grey low smoke and fume polyvinyl-chloride 5 X SL 28810 Electrical & Mechanical Characteristics 8 X SL 28810 Impedance 75 ± 3 Ohm

Nominal capacitance 67 pF/m Velocity of propagation 66%

Ca

10 X SL 28810 SLS 37885

Inner conductor resistance 62 Ohm/Km

Outer conductor resistance 8.5 Ohm/Km 4X

SL 37885

Operating temperature range -25 °C - +80 °C Cable weight (approx.) 59.8 Kg/Km

SLS 50755

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

76

5 X SL 37885

SLS 64955

Attenuation (dB/100 m) 7.2 10.5 15.5 22.3 25.1 28.0 33.9 37.1

www.caledonian-cables.co.uk

www.caledonian-cables.net


Broadcast Coaxial Cables RG 59 FX Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Plain copper Low density PE Plain copper PVC or LSZH

n o is

7 x 0.20 mm Φ3.70 ± 0.10 mm 160 x 0.10 mm 92% Φ6.20 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 82 Ohm/Km 15 Ohm/Km -30 °C - +70 °C 14.0 Kg/Km 49.4 Kg/Km >55 dB

PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.9 11.5 16.8 24.1 27.3 30.4 36.8 40.1

Attenuation (dB/100ft) 2.41 3.51 5.12 7.35 8.32 9.27 11.22 12.23

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >25dB >22dB

www.addison-cables.com

77


Broadcast Coaxial Cabless RF 175 AF Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Tinned copper Foam PE Tinned copper

7 x 0.13 mm Φ1.70 ± 0.10 mm 80 x 0.10 mm 92% Φ2.60 ± 0.10 mm

PVC or LSZH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 66% >5000 Mohm.Km 20.5 Ohm/Km 30.0 Ohm/Km -25 °C - +80 °C 6.9 Kg/Km 11.3 Kg/Km >50 dB

n a i n

o d le

Ca

PVC or LSZH sheath Tinned copper outer conductor Tinned copper inner conductor Foamed PE dielectric

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 11.7 15.8 24.6 36.5 41.3 44.7 53.8 57.7

Attenuation (dB/100ft) 3.57 4.82 7.50 11.13 12.59 13.63 16.40 17.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

78

>20dB >18dB >16dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Broadcast Coaxial Cables SLS 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is PVC

0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.70 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 12.2 Kg/Km 30.5 Kg/Km >85 dB

PVC sheath AL+polyester+AL tape Plain copper inner conductor Gas injected foam PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 7.3 14.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6

Attenuation (dB/100 ft) 2.23 4.48 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

www.addison-cables.net

>32dB >27dB >21dB

www.addison-cables.com

79


Broadcast Coaxial Cabless 5 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement

Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC PVC PVC

Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

PVC reinforcement

Attenuation

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 61.0 Kg/Km 192.7 Kg/Km >85 dB

80

Ca

Attenuation (dB/100 m) 7.8 15.1 23.5 32.7 35.6 41.7 44.8 48.0 54.2 57.8

Attenuation (dB/100 ft) 2.38 4.60 7.16 9.97 10.85 12.71 13.66 14.63 16.52 17.62

>32dB >27dB >23dB

www.caledonian-cables.co.uk

n a i n

o d le

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

SLS28810

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ14.20 ± 0.40 mm

PVC sheath

Electrical & Mechanical Characteristics

0.6 mm Φ2.80 ± 0.10 mm

www.caledonian-cables.net


Broadcast Coaxial Cables 8 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath

Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is

d d A

PVC PVC

0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ18.00 ± 0.80 mm

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 92.6 Kg/Km 371.6 Kg/Km >85 dB

PVC sheath SLS28810

Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 7.3 13.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6

Attenuation (dB/100 ft) 2.23 4.18 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

www.addison-cables.net

>32dB >27dB >21dB

www.addison-cables.com

81


Broadcast Coaxial Cabless 10 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath

Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC PVC

0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ22.00 ± 0.50 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 122.0 Kg/Km 533.3 Kg/Km >85 dB

n a i n

o d le

Ca

PVC sheath SLS28810

Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 7.3 13.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6

Attenuation (dB/100 ft) 2.23 4.18 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

82

>32dB >27dB >21dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

Broadcast Coaxial Cables SLS 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is PVC

0.8 mm Φ3.65 ± 0.10 mm 100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm

Electrical & Mechanical Characteristics

dd

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 21.8 Kg/Km 49.5 Kg/Km >90 dB

PVC sheath AL+polyester+AL tape Plain copper inner conductor Foamed PE dielectric Tinned copper shield

Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 6.0 12.5 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4

Attenuation (dB/100 ft) 1.83 3.81 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

www.addison-cables.net

>32dB >30dB >26dB

www.addison-cables.com

83


Broadcast Coaxial Cabless 4 X SL 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC(yellow green red blue) Black PVC PVC

0.8 mm Φ3.65 ± 0.10 mm 100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm Φ16.90 ± 0.40 mm 5 x Φ2.40 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 87.2 Kg/Km 340.1 Kg/Km >90 dB

n a i n

o d le

Ca

PVC reinforcement PVC sheath SLS37885

Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 6.0 11.6 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4

Attenuation (dB/100 ft) 1.83 3.54 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

84

>32dB >30dB >26dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Broadcast Coaxial Cables 5 X SL 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement 1 Reinforcement 2

Plain copper Foam PE Aluminium + polyester + Aluminium tape

Green PVC Black PVC PVC PVC

PVC reinforcement

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 100.0 Kg/Km 440.3 Kg/Km >90 dB

SLS37885

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

PVC sheath

Electrical & Mechanical Characteristics

& n

100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm Φ19.40 ± 0.50 mm Φ4.20 ± 0.10 mm 5 x Φ2.30 ± 0.10 mm

Tinned copper

n o is

d d A

0.8 mm Φ3.65 ± 0.10 mm

Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 6.0 11.6 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4

Attenuation (dB/100 ft) 1.83 3.54 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

www.addison-cables.net

>32dB >30dB >26dB

www.addison-cables.com

85


Broadcast Coaxial Cabless SLS 50755 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper Blue PVC

7 x 0.40 mm Φ4.95 ± 0.10 mm 100% 96 x 0.15 mm 71% Φ7.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 53 pF/m 84% >5000 Mohm.Km 20.5 Ohm/Km 13.5 Ohm/Km -25 °C - +80 °C 24.6 Kg/Km 56.25 Kg/Km >85 dB

n a i n

o d le

Ca

PVC sheath AL+polyester+AL tape

Plain copper inner conductor Foam PE dielectric Tinned copper shield

Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 4.4 9.5 13.7 19.2 21.0 24.7 26.6 28.7 32.4 34.7

Attenuation (dB/100 ft) 1.34 2.90 4.18 5.85 6.40 7.53 8.11 8.75 9.88 10.58

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

86

>30dB >26dB >22dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Broadcast Coaxial Cables SLS 64955 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper

n o is PVC

1.40 mm Φ6.4 ± 0.10 mm 100% 192 x 0.15 mm 95% Φ9.20 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

& n

75±5 Ohm 53 pF/m 84% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -25 °C - +80 °C 49.2 Kg/Km 109.2 Kg/Km >84 dB

PVC sheath AL+polyester+AL tape Plain copper inner conductor Foamed PE dielectric Tinned copper shield

Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400

Attenuation (dB/100 m) 3.4 7.4 10.7 14.8 16.3 19.4 20.8 22.5 25.3 27.0

Attenuation (dB/100 ft) 1.04 2.26 3.26 4.51 4.97 5.91 6.34 6.86 7.71 8.23

Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz

www.addison-cables.net

>29dB >27dB >23dB

www.addison-cables.com

87


Broadcast Hybrid Coaxial Cabless

M17 /RG Coaxial Cables Hybrid 75Ohm Twin RG 6

n a i n

Twin RG 59 RG175 + 3 x 0.22mm2

o d le

2

2

RG175 + 2 x 0.22mm + 2 x 0.5mm

Ca

RG175 + 4 x 0.22mm2 + 2 x 0.75mm2 RG175 + 2 x 0.75mm2+ 10 x 0.5mm2 RG59 + 2 x 0.5mm2

RG59 + 2 x 0.75mm2 RG59 + 2 x 1.00mm2 RG59 + 2 x 1.5mm2

RG59 + 2 x 0.75mm2+ 2 x 0.22mm2 RG59 + 2 x 1.50mm2+ 2 x 0.25mm2 RG59 + 2 x 1.50mm2+ 2 x 1.00mm2 RG59 + 2 x 2.50mm2+ 2 x 0.22mm2 RG59 + 2 x 0.75mm2+10x 0.50mm2

88

www.caledonian-cables.co.uk

www.caledonian-cables.net


Broadcast Coaxial Cables Hybrid Coaxial Cables Twin RG 6 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Anealed copper Foam PE Al-PES-Al foil Tinned copper

n o is PVC

Φ1.02 mm Φ4.57 mm 100% 60% Φ6.8 - 13.9mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

& n

75±5 Ohm 57 pF/m 78% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -40 °C - +70 °C 100 Kg/Km

PVC sheath AL+PES+AL foil Anealed copper inner conductor Foamed PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 200 500 860 1000 1500 2000 2400 3000

Attenuation (dB/100 m) 9.9 15.2 20.7 22.5 27.0 30.8 34.1 39.0

www.addison-cables.net

Attenuation (dB/100 ft) 3.02 4.63 6.31 6.86 8.23 9.39 10.40 11.89

www.addison-cables.com

89


Hybrid Coaxial Cabless Twin RG 59 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath

Anealed copper Foam PE Al-PES-Al foil

0.81 mm Φ3.6 mm 100%

Tinned copper

60% Φ5.9 - 12.7mm

PVC

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)

75±5 Ohm 57 pF/m 78% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -40°C - +70 °C 75 Kg/Km

PVC sheath AL+PES+AL foil

n a i n

o d le

Ca

Anealed copper inner conductor Foamed PE dielectric Tinned copper outer conductor

Attenuation Frequency(MHz) 200 500 860 1000 1500 2000 2400 3000

90

Attenuation (dB/100 m) 12.4 18.8 25.3 27.6 34.1 40.4 44.8 50.1

www.caledonian-cables.co.uk

Attenuation (dB/100 ft) 3.78 5.73 7.71 8.41 10.40 12.32 13.66 15.27

www.caledonian-cables.net


Hybrid Coaxial Cables CK175/C3:RG175AF + 3 x 0.22mm2 Construction PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor

PVC outer sheath Plain copper inner conductor PVC insulation Inner conductor1 Dielectric Outer conductor Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath

& n

Plain copper Low density PE Tinned copper

n o is

d d A

PVC Plain copper PVC(Green +Yellow + Red) PVC/LSOH

9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 3 x 0.22 mm2 3 x Φ1.00 ± 0.10 mm Φ5.30 ± 0.20 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82 Ohm/Km 1.2 KV/0.25 KV 11.85 Kg/Km 43.2 Kg/Km >50 dB

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0

Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>20dB >20dB >20dB

www.addison-cables.com

91


Hybrid Coaxial Cabless CK175/F2C2:RG175AF + 2 x 0.22mm2 + 2 x 0.5mm2 Construction

PVC overall sheath PVC insulation 3

PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor

Inner conductor 1 PVC outer sheath Dielectric Outer conductor Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

Plain copper inner conductor 3 Plain copper inner conductor 2 PVC insulation 2

Plain copper Low density PE Tinned copper

9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm 2 x 0.50 mm2 2 x Φ1.50 ± 0.10 mm Φ6.20 ± 0.20 mm

PVC Plain copper PVC Plain copper PVC PVC

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 - 0.50 mm2 Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

n a i n

o d le

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82Ohm/Km - 39 Ohm/Km 1.2 KV/0.25 KV 18.85 Kg/Km 61.55 Kg/Km >50 dB

Ca

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0

Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

92

>20dB >20dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Hybrid Coaxial Cables CK175/H2C4:RG175AF + 4 x 0.22mm2 + 2 x 0.75mm2 Construction

PVC overall sheath PVC insulation 2

PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor

Inner conductor 1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

& n

Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3

Plain copper Low density PE Tinned copper

d d A

n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH

9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 4 x 0.22 mm2 4 x Φ1.00 ± 0.10 mm 2 x 0.75 mm2 2 x Φ1.70 ± 0.10 mm Φ7.00 ± 0.20 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2/ 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82Ohm/Km/26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 27.45 Kg/Km 82.75 Kg/Km >50 dB

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0

Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz www.addison-cables.net

>20dB >20dB >20dB www.addison-cables.com

93


Hybrid Coaxial Cabless CK175/H2F10:RG175AF + 2 x 0.75mm2+ 10 x 0.5mm2 Construction

PVC insulation 2 Plain copper inner conductor 2

PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor

Inner conductor 1 Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

PVC insulation 3 Plain copper inner conductor 3

Copper covered steel(CCS) Low density PE Tinned copper PVC Plain copper PVC Plain copper PVC PVC/LSOH

9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 10 x 0.5 mm2 10 x Φ1.50 ± 0.10 mm Φ9.90 ± 0.30 mm

n a i n

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.50 mm2/0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 39Ohm/Km/26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 64.45 Kg/Km 172.65 Kg/Km >50 dB

o d le

Ca

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0

Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

94

>20dB >20dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

Hybrid Coaxial Cables CK 059/F2:RG59BX + 2 x 0.5mm2 Construction Inner conductor1 Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH

dd

n o is

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 0.50 mm2 2 x Φ1.50 ± 0.10 mm Φ10.30 ± 0.30 mm

Electrical & Mechanical Characteristics

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

Attenuation

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 39 Ohm/Km 1.2 KV/0.25 KV 24.5 Kg/Km 142.8 Kg/Km >55 dB PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

PVC overall sheath PVC insulation Plain copper inner conductor

Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >24dB

www.addison-cables.com

95


Hybrid Coaxial Cabless CK 059/H2:RG59BX + 2 x 0.75mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 0.75 mm2 2 x Φ1.70 ± 0.10 mm Φ10.30 ± 0.30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

Attenuation

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 26 Ohm/Km 2 KV/0.3 KV 29.1 Kg/Km 147.6 Kg/Km >55 dB

Frequency(MHz) 50 100 200 400 500 600 860 1000

o d le

Ca

PVC overall sheath PVC insulation Plain copper inner conductor

n a i n

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

96

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

Hybrid Coaxial Cables CK 059/K2:RG59BX + 2 x 1.00mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH

n o is

dd

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 1.00 mm2 2 x Φ2.40 ± 0.10 mm Φ10.90 ± 0.30 mm

Electrical & Mechanical Characteristics

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 18 Ohm/Km 2 KV/0.3 KV 33.5 Kg/Km 166.0 Kg/Km >55 dB

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

PVC overall sheath PVC insulation Plain copper inner conductor

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz www.addison-cables.net

>31dB >28dB >24dB www.addison-cables.com

97


Hybrid Coaxial Cabless CK 059/M2:RG59BX + 2 x 1.50mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 1.50 mm2 2 x Φ2.60 ± 0.10 mm Φ11.490 ± 0.30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 12 Ohm/Km 2 KV/0.3 KV 42.1 Kg/Km 186.9 Kg/Km >55 dB

PVC overall sheath PVC insulation Plain copper inner conductor

o d le

Ca

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

n a i n

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

98

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Hybrid Coaxial Cables CK 059/H2C2:RG59BX + 2 x 0.75mm2+ 2 x 0.22mm2 PVC overall sheath PVC insulation 2

Construction PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Inner conductor 1 PVC outer sheath Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

& n

Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3

Copper covered steel(CCS) Low density PE Plain copper

n o is

d d A

PVC Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm Φ10.40 ± 0.30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 / 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 82 Ohm/Km /26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 33.1 Kg/Km 153.4 Kg/Km >55 dB

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >24dB

www.addison-cables.com

99


Hybrid Coaxial Cabless CK 059/M2D2:RG59BX + 2 x 1.5mm2+ 2 x 0.25mm2 PVC overall sheath PVC insulation 2

Construction PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Inner conductor 1 Dielectric PVC outer sheath Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 1.5 mm2 2 xΦ2.60 ± 0.10 mm 2 x 0.25 mm2 2 x Φ1.15 ± 0.10 mm Φ10.90 ± 0.30 mm

n a i n

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.25 mm2 /1.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 75 Ohm/Km / 12 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 33.1 Kg/Km 153.4 Kg/Km >55 dB

o d le

Ca

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

100

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Hybrid Coaxial Cables CK 059/M2K2:RG59BX + 2 x 1.5mm2+ 2 x 1.00mm2 Construction

PVC overall sheath PVC insulation 2

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Inner conductor 1 sheath PVC outer Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

& n

Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3

Copper covered steel(CCS) Low density PE Plain copper

d d A

n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 1.50 mm2 2 x Φ2.60 ± 0.10 mm 2 x 1.00 mm2 2 x Φ1.70 ± 0.10 mm Φ12.00 ± 0.30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 1.00 mm2 / 1.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 18 Ohm/Km/12 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 60.1 Kg/Km 220.7 Kg/Km >55 dB

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >24dB

www.addison-cables.com

101


Hybrid Coaxial Cabless CK 059/S2C2:RG59BX + 2 x 2.5mm2+ 2 x 0.22mm2 Construction

PVC overall sheath PVC insulation 2

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Inner conductor 1 PVC outer sheath Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3

Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 2.50 mm2 2 x Φ3.40 ± 0.10 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm Φ12.00 ± 0.30 mm

n a i n

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 / 2.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 82 Ohm/Km/8 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 63.5 Kg/Km 221.4 Kg/Km >55 dB

o d le

Ca

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

102

>31dB >28dB >24dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Hybrid Coaxial Cables CK 059/H2F10:RG59BX + 2 x 0.75mm2+ 10 x 0.5mm2 Construction

PVC insulation 2 Plain copper inner conductor 2

PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor

Inner conductor 1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath

& n

PVC insulation 3 Plain copper inner conductor 3

Copper covered steel(CCS) Low density PE Plain copper

d d A

n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH

0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 10 x 0.50 mm2 10 x Φ1.50 ± 0.10 mm Φ12.80 ± 0.30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.50 mm2 - 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 39 Ohm/Km - 26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 74.1 Kg/Km 254.9 Kg/Km >55 dB

Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0

Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>31dB >28dB >24dB

www.addison-cables.com

103


Triaxial Cabless Hybrid Coaxial

Triaxial Cables Tri-RG178 Tri-RG179

n a i n

Tri-RG180

o d le

Tri-RG316 Tri-RG393

Ca

Tri-RG400 Tri-RG403 CTX 41

CTX 44 Flex CTX 47 Flex CTX 64 CTX 65 Flex CTX 80 Flex

104

www.caledonian-cables.co.uk

www.caledonian-cables.net


TriaxialCoaxial Cables Cables Hybrid Tri-RG178 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper FEP Silver plated copper FEP

n o is

7 x 0.10 mm Φ0.86 ± 0.10 mm Φ1.26 ± 0.10 mm Φ1.80 ± 0.10 mm Φ2.20 ± 0.10 mm Φ2.85 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

& n

50±5 Ohm 96.5 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 1 KV -55°C - +200 °C 24 Kg/Km >60 dB

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 400 1000 3000

Attenuation (dB/100 m) 45.3 91.2 145.7 257.2

www.addison-cables.net

Max. Attenuation(dB/100ft) 13.8 27.8 44.4 78.4

www.addison-cables.com

105


Triaxial Cabless Tri-RG179 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.1mm) FEP

7 x 0.10 mm Φ1.60 ± 0.10 mm Φ2.15 ± 0.10 mm Φ2.55 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.6 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

75±5 Ohm 63 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 0.9 KV -55°C - +200 °C 31 Kg/Km >60 dB

n a i n

o d le

Ca

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric

Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

106

Attenuation (dB/100 m) 28 39 56 85 98 110 121 128 144

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 8.5 11.9 17.1 25.9 29.9 33.5 36.9 39.0 43.9

www.caledonian-cables.net


Triaxial Cables Tri-RG180 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.13mm) FEP

n o is

7 x 0.10 mm Φ2.60 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.60 ± 0.10 mm Φ4.40 ± 0.10 mm Φ4.80 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

& n

Nom.95±5 Ohm 50 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 1.0 KV -55°C - +200 °C 53 Kg/Km >60 dB

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 21 30 43 65 76 85 94 99 111

www.addison-cables.net

Max. Attenuation(dB/100ft) 6.4 9.1 13.1 19.8 23.2 25.9 28.7 30.2 33.8

www.addison-cables.com

107


Triaxial Cabless Tri-RG316 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper( 0.1mm) FEP Silver plated copper(0.1mm) FEP

7 x 0.17 mm Φ1.52 ± 0.10 mm Φ2.05 ± 0.10 mm Φ2.50 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.60 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 1.0 KV -55°C - +200 °C 31 Kg/Km >60 dB

n a i n

o d le

Ca

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

108

Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4

www.caledonian-cables.net


Triaxial Cables Tri-RG393 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper Solid PTFE Silver plated copper (0.16mm) FEP Silver plated copper (0.2mm) FEP

n o is

7 x 0.80 mm Φ7.25 ± 0.10 mm Φ7.95 ± 0.10 mm Φ9.00 ± 0.10 mm Φ9.90 ± 0.10 mm Φ11.10 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 4.4 KV

-55°C - +200 °C 290 Kg/Km >60 dB

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 7 10 14 22 25 29 32 34 39

www.addison-cables.net

Max. Attenuation(dB/100ft) 2.1 3.0 4.3 6.7 7.6 8.8 9.8 10.4 11.9

www.addison-cables.com

109


Triaxial Cabless Tri-RG400 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper Solid PTFE Silver plated copper(0.13mm) FEP Silver plated copper (0.13mm) FEP

19 x 0.20 mm Φ2.95 ± 0.10 mm Φ3.55 ± 0.10 mm Φ4.30 ± 0.10 mm Φ4.90 ± 0.10 mm Φ5.70 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 1.8 KV -55°C - +200 °C 78 Kg/Km >60 dB

n a i n

o d le

Ca

Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric

Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

110

Attenuation (dB/100 m) 15 22 31 47 55 62 68 72 81

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 4.6 6.7 9.4 14.3 16.8 18.9 20.7 21.9 24.7

www.caledonian-cables.net


Triaxial Cables Tri-RG403 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath

Silver plated copper covered steel(SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.1mm) FEP

n o is

7 x 0.10 mm Φ0.84 ± 0.10 mm Φ1.30 ± 0.10 mm Φ1.90 ± 0.10 mm Φ2.35 ± 0.10 mm Φ2.95 ± 0.10 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness

& n

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 0.5 KV

-55°C - +200 °C 21 Kg/Km >60 dB Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 50 67 95 145 165 185 204 215 240

www.addison-cables.net

Max. Attenuation(dB/100ft) 15.2 20.4 29.0 44.2 50.3 56.4 62.2 65.5 73.2

www.addison-cables.com

111


Triaxial Cabless CTX 41 Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH

1.00 mm Φ4.10 ± 0,10 mm 168 x 0.13 mm 95% Φ6.60 ± 0,10 mm h. 20 mm 192 x 0.15 mm 94% Φ8.50 ± 0.10 mm

n a i n

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 7.0 Ohm/Km 7.5 Ohm/Km -25°C - +80 °C 63.3 Kg/Km 111.2 Kg/Km >70 dB

o d le

Ca

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 5.2 7.6 10.8 16.0 18.6 20.8 25.6 28.0

Max. Attenuation(dB/100ft) 1.6 2.3 3.3 4.9 5.7 6.3 7.8 8.5

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

112

>30dB >29dB >28dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Triaxial Cables CTX 44 FLEX

Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Tinned copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

& n

Tinned copper Foam PE Silver plated copper

n o is

d d A

PE Spiral non-migrating tape Plain copper

PVC

7 x 0.35 mm Φ4.40 ± 0.10 mm 168 x 0.12 mm 94% Φ6,60 ± 0.10 mm h. 20 mm 168 x 0.15 mm 93% Φ9.00 ± 0.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 8.5Ohm/Km 6.0 Ohm/Km -30°C - +70 °C 58.7 Kg/Km 115.1 Kg/Km >70 dB

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 5.5 8.1 11.4 17.1 20.0 22.3 27.4 29.9

Max. Attenuation(dB/100ft) 1.7 2.5 3.5 5.25 6.1 6.8 8.4 9.1

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >25dB >23dB

www.addison-cables.com

113


Triaxial Cabless CTX 47 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH

7 x 0.40 mm Φ4.70 ± 0.10 mm 168 x 0.13 mm 94% Φ6.60 ± 0.10 mm h. 20 mm 192 x 0.15 mm 94% Φ8.70 ± 0.10 mm

n a i n

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 20.5 Ohm/Km 7.3Ohm/Km 7.5 Ohm/Km -25°C - +80 °C 64.5 Kg/Km 116.1 Kg/Km >70 dB

o d le

Ca

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 5.2 7.7 10.9 16.3 19.0 21.2 26.1 28.5

Max. Attenuation(dB/100ft) 1.6 2.3 3.3 5.0 5.8 6.5 8.0 8.7

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

114

>27dB >23dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Triaxial Cables CTX 64 Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

& n

Silver plated copper Foam PE Silver plated copper

n o is

d d A

PE Spiral non-migrating tape Plain copper

PVC/LSOH

1.40 mm Φ6.40 ± 0.10 mm 216x 0.13 mm 92% Φ8.60 ± 0.10 mm h. 27 mm 216 x 0.16 mm 92% Φ11.00 ± 0.18 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 11.5 Ohm/Km 6 Ohm/Km 5.8 Ohm/Km -25°C - +80 °C 88.1 Kg/Km 169.25 Kg/Km >70 dB

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 3.7 5.4 8.2 12.1 13.8 15.6 18.8 20.6

Max. Attenuation(dB/100ft) 1.1 1.6 2.5 3.7 4.2 4.8 5.7 6.3

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >28dB >26dB

www.addison-cables.com

115


Triaxial Cabless CTX 65 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 6.5 Ohm/Km 5.8 Ohm/Km -25°C - +80 °C 85.2 Kg/Km 165.95 Kg/Km >70 dB

19 x 0,28 mm Φ6,50 ± 0,10 mm 216x 0,13 mm 92% Φ8,70 ± 0,10 mm h. 27 mm 216 x 0,16 mm 92% Φ11.00 ± 0,18 mm

n a i n

o d le

Ca

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 4.4 6.2 9.1 13.3 15.2 17.1 20.6 22.4

Max. Attenuation(dB/100ft) 1.3 1.9 2.8 4.1 4.6 5.2 6.3 6.8

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

116

>28dB >25dB >23dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Triaxial Cables CTX 80 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath

Construction

n o is

Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath

& n

d d A

Silver plated copper Foam PE Silver plated copper

PE Spiral non-migrating tape Plain copper

PVC/LSOH

7 x 0,65 mm Φ8.00 ± 0,10 mm 216x 0,15 mm 92% Φ10.00 ± 0,10 mm h. 27 mm 216 x 0,18 mm 90% Φ13.00 ± 0,30 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness

75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 8.0 Ohm/Km 5.0 Ohm/Km 3.5 Ohm/Km -30°C - +70 °C 117.6 Kg/Km 224.35 Kg/Km >70 dB

Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000

Attenuation (dB/100 m) 3.4 5.1 7.5 10.9 12.4 14.2 17.0 18.8

Max. Attenuation(dB/100ft) 1.0 1.6 2.3 3.3 3.8 4.3 5.2 5.7

Return Loss 30-300 MHz 300-600 MHz 600-900 MHz

www.addison-cables.net

>30dB >28dB >24dB

www.addison-cables.com

117


Mininature Coaxial Cabless

Mininature Coaxial Cables 0.81 mm Mini-Coax 1.13 mm Mini-Coax

n a i n

1.32 mm Mini-Coax

o d le

1.37 mm Mini-Coax 1.48 mm Mini-Coax

Ca

RG174 Mini-Coax RG178 Mini-Coax

RGD178 Mini-Coax RG179 Mini-Coax RG316 Mini-Coax RG316D Mini-Coax 50 VMTX 75 VMTX

118

www.caledonian-cables.co.uk

www.caledonian-cables.net


Mininature Coaxial Cables 0.81 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper PFA Silver plated copper

7 x 0.05 mm Φ0.40 mm 0.05 mm 95% Φ0.81 mm

PFA

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V

Test insulation voltage

Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath

Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000

Attenuation (dB/100 m) 320 400 580 650 740 940

www.addison-cables.net

Max. Attenuation(dB/100ft) 97.5 121.9 176.8 198.1 225.6 286.5

www.addison-cables.com

119


Mininature Coaxial Cabless 1.13 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated annealed copper PFA Silver plated annealed copper PFA

7 x 0.08 mm Φ0.68 mm 0.05 mm 95% Φ1.13 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Test insulation voltage

50±3 Ohm 95.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V

n a i n

o d le

Ca

Silver plated annealed copper outer conductor PFA dielectric

Silvered copper inner conductor PFA sheath

Attenuation Frequency (GHz) 1000 2000 3000 4000 5000 6000

120

Attenuation (dB/100 m) 230 310 390 460 510 580

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 70.1 94.5 118.9 140.2 155.4 176.8

www.caledonian-cables.net


Mininature Coaxial Cables 1.32 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated annealed copper PFA Silver plated annealed copper

7 x 0.08 mm Φ0.66 mm 0.05 mm 91-93% Φ1.32 mm

PFA

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Test insulation voltage

50±3 Ohm 100 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V

Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath

Attenuation Frequency (GHz) 1000 2000 3000 4000 5000 6000

Attenuation (dB/100 m) 230 330 400 460 510 560

www.addison-cables.net

Max. Attenuation(dB/100ft) 70.1 100.6 121.9 140.2 155.4 170.7

www.addison-cables.com

121


Mininature Coaxial Cabless 1.37 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated annealed copper PFA Silver plated annealed copper PFA

7 x 0.102 mm Φ0.89 mm 0.05 mm 95% Φ1.37 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Test insulation voltage

50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1KV

n a i n

o d le

Ca

Silver plated annealed copper outer conductor PFA dielectric

Silvered copper inner conductor PFA sheath

Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000

122

Attenuation (dB/100 m) 160 230 290 340 400 430

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 48.8 70.1 88.4 103.6 121.9 131.1

www.caledonian-cables.net


Mininature Coaxial Cables 1.48 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated annealed copper PFA Silver plated annealed copper

7 x 0.102 mm Φ0.86 mm 0.08 mm 95% Φ1.48 mm

PFA

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Test insulation voltage

50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1KV

Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath

Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000

Attenuation (dB/100 m) 155 255 360 410 460 550

www.addison-cables.net

Max. Attenuation(dB/100ft) 47.2 77.7 109.7 125.0 140.2 167.6

www.addison-cables.com

123


Mininature Coaxial Cabless RG174 Mini-Coax Construction Inner conductor Dielectric Outer conductor (shield 1) Outer conductor (shield 2) Sheath

Copper clad steel(CCS) Solid PE Silver plated copper Silver plated copper PVC

7 x 0.16 mm Φ1.52 mm 0.1mm 0.1mm Φ2.80 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Cable weight (approx.)

50±3 Ohm 101 pF/m 66% - Mohm.Km - Ohm/Km - Ohm/Km -40°C - +85 °C 12 kg/km

n a i n

o d le

Ca

PVC sheath Solid PE dielectric Copper covered steel inner conductor Silvered copper outer conductor1 Silvered copper outer conductor2

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

124

Attenuation (dB/100 m) 28 40 58 90 106 119 130 138 155

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 8.5 12.2 17.7 27.4 32.3 36.3 39.6 42.1 47.2

www.caledonian-cables.net


Mininature Coaxial Cables RG178 Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper PTFE Silver plated copper FEP

n o is

7 x 0.10 mm Φ0.84 mm 0.10 mm 95% Φ1.75 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Cable weight (approx.)

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 7.8 kg/km

FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 46 65 93 140 162 182 200 211 236

www.addison-cables.net

Max. Attenuation(dB/100ft) 14.0 19.8 28.3 42.7 49.4 55.5 61.0 64.3 71.9

www.addison-cables.com

125


Mininature Coaxial Cabless RGD178 Mini-Coax Construction Inner conductor Dielectric Outer conductor (shield 1) Outer conductor (shield 2) Sheath

Silver plated copper Solid PTFE Silver plated copper Silver plated copper FEP

7 x 0.10 mm Φ0.84 mm 0.10 mm 0.10 mm Φ2.25 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Cable weight (approx.)

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 14 kg/km

o d le

Ca

FEP sheath Solid PTFE dielectric Silvered copper covered steel inner conductor Silvered copper outer conductor1

n a i n

Silvered copper outer conductor2

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

126

Attenuation (dB/100 m) 46 65 93 140 162 182 200 211 236

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 14.0 19.8 28.3 42.7 49.4 55.5 61.0 64.3 71.9

www.caledonian-cables.net


Mininature Coaxial Cables RG179 Mini-Coax Construction Inner conductor Dielectric Outer conductor Sheath

Silver plated copper Solid PTFE Silver plated copper FEP

7 x 0.10 mm Φ1.60 mm 0.10 mm Φ2.50 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

d d A

Cable weight (approx.)

75±5 Ohm 63 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km

FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 28 39 56 85 98 110 121 128 144

www.addison-cables.net

Max. Attenuation(dB/100ft) 8.5 11.9 17.1 25.9 29.9 33.5 36.9 39.0 43.9

www.addison-cables.com

127


Mininature Coaxial Cabless RG316 Mini-Coax Construction Inner conductor Dielectric Outer conductor Sheath

Silver plated copper Solid PTFE Silver plated copper FEP

7 x 0.18 mm Φ1.56 mm 0.10 mm Φ2.45 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Cable weight (approx.)

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km

n a i n

o d le

FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor

Ca

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

128

Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4

www.caledonian-cables.net


Mininature Coaxial Cables RG316D Mini-Coax Construction Inner conductor Dielectric Outer conductor 1 Shield coverage Outer conductor 2 Shield coverage Sheath

Silver plated copper Solid PTFE Silver plated copper Silver plated copper

n o is

d d A

FEP

7 x 0.18 mm Φ1.56 mm 0.10 mm 95% 0.10 mm 93% Φ2.94 mm

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Cable weight (approx.)

50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km

FEP sheath Solid PTFE dielectric Silvered copper covered steel inner conductor Silvered copper outer conductor1 Silvered copper outer conductor2

Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500

Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139

www.addison-cables.net

Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4

www.addison-cables.com

129


Mininature Coaxial Cabless 50VMTX Construction Inner conductor Dielectric Outer conductor Sheath

Silver plated copper clad steel FEP/PTFE Tinned copper braid FEP

0.17 mm Φ0.52 mm Φ0.72 mm Φ1.17 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Cable weight (approx.)

50±5 Ohm 94.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 3kg/km

n a i n

o d le

Ca

FEP sheath Tinned copper outer conductor Silver plated copper clad steel inner conductor FEP/PTFE dielectric

Attenuation Frequency (MHz) 10 100 400 1000 2000 3000

130

Attenuation (dB/100 m) 22 54 115 220 320 450

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 6.7 16.5 35.1 67.1 97.6 137.2

www.caledonian-cables.net


Mininature Coaxial Cables

& n

75VMTX Construction Inner conductor Dielectric Outer conductor Sheath

Silver plated copper clad steel FEP/PTFE Tinned copper braid FEP

0.10 mm Φ0.57 mm Φ0.77 mm Φ1.22 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

d d A

Cable weight (approx.)

75±5 Ohm 72.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 3kg/km

FEP sheath Tinned copper outer conductor Silver plated copper clad steel inner conductor FEP/PTFE dielectric

Attenuation Frequency (MHz) 10 100 400 1000 2000 3000

Attenuation (dB/100 m) 36 70 135 220 320 390

www.addison-cables.net

Max. Attenuation(dB/100ft) 11.0 21.3 41.2 67.1 97.6 118.9

www.addison-cables.com

131


50 Mininature Ohm RF Coaxial Cabless

50Ohm RF Coaxial Cables ALMR100 ALMR195

n a i n

A LMR200 A LMR240

o d le

ALMR300

Ca

ALMR400 ALMR500 ALMR600 3D-FB 5D-FB 7D-FB 8D-FB 10D-FB 12D-FB

132

www.caledonian-cables.co.uk

www.caledonian-cables.net


Mininature 50 Ohm RFCoaxial CoaxialCables Cables ALMR100 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

n o is

0.46 mm Φ1.52 mm Φ1.65 mm Φ2.11 mm Φ2.79 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Min.bending radius

50±3 Ohm 101.1 pF/m 70% >5000 Mohm.Km 266 Ohm/Km 31.2 Ohm/Km -40°C - +85 °C 14 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

Attenuation (dB/100 m) 12.9 16.7 29.4 35.8 51.9 74.9 98.7 109.0 115.5 130.6 143.8 210.3

www.addison-cables.net

Max. Attenuation(dB/100ft) 3.9 5.1 9.0 10.9 15.8 22.8 30.1 33.2 35.2 39.8 43.8 64.1

www.addison-cables.com

133


50 Ohm RF Coaxial Cabless ALMR195 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

Φ3.61 mm Φ9.40 mm Φ9.55 mm Φ10.3 mm Φ12.7 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Min.bending radius

50±3 Ohm 79.7 pF/m 80% >5000 Mohm.Km 24.94 Ohm/Km 16.08 Ohm/Km -40°C - +85 °C 25 mm

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

134

Attenuation (dB/100 m) 6.5 8.4 14.6 17.7 25.5 36.5 47.7 52.5 55.4 62.4 67.5 93.0

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 2.0 2.6 4.5 5.4 7.8 11.1 14.5 16.0 16.9 19.0 20.6 28.3

www.caledonian-cables.net


50 Ohm RF Coaxial Cables ALMR200 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

n o is

Φ1.12 mm Φ2.95 mm Φ3.07 mm Φ3.66 mm Φ4.95 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Min.bending radius

50±3 Ohm 80.3 pF/m 83% >5000 Mohm.Km 17.6 Ohm/Km 16.1 Ohm/Km -40°C - +85 °C 27 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

Attenuation (dB/100 m) 5.8 7.5 13.1 15.9 22.8 32.6 42.4 46.6 49.3 55.4 60.0 86.5

www.addison-cables.net

Max. Attenuation(dB/100ft) 1.8 2.3 4.0 4.8 6.9 9.9 12.9 14.2 15.0 16.9 18.3 26.4

www.addison-cables.com

135


50 Ohm RF Coaxial Cabless ALMR240 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

Φ1.42 mm Φ3.81 mm Φ3.94 mm Φ4.50 mm Φ6.01 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Min.bending radius

50±3 Ohm 79.4 pF/m 84% >5000 Mohm.Km 10.5 Ohm/Km 12.76 Ohm/Km -40°C - +85 °C 30 mm

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

136

Attenuation (dB/100 m) 4.4 5.7 9.9 12.0 17.3 24.8 32.4 35.6 37.7 42.4 46.5 66.8

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 1.3 1.7 3.0 3.7 5.3 7.6 9.9 10.9 11.5 12.9 14.2 20.4

www.caledonian-cables.net


50 Ohm RF Coaxial Cables ALMR300 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

n o is

Φ1.78 mm Φ4.83 mm Φ4.98 mm Φ5.72 mm Φ7.62 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Min.bending radius

50±3 Ohm 78.8 pF/m 85% >5000 Mohm.Km 7.01 Ohm/Km 7.26 Ohm/Km -40°C - +85 °C 38 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

Attenuation (dB/100 m) 3.5 4.5 7.9 9.6 13.8 19.9 26.0 28.7 30.3 34.2 37.5 54.2

www.addison-cables.net

Max. Attenuation(dB/100ft) 1.1 1.4 2.4 2.9 4.2 6.1 7.9 8.7 9.2 10.4 11.4 16.5

www.addison-cables.com

137


50 Ohm RF Coaxial Cabless ALMR400 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

Φ2.74 mm Φ7.24 mm Φ7.39 mm Φ8.13 mm Φ10.29 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Min.bending radius

50±3 Ohm 101.1 pF/m 85% >5000 Mohm.Km 2.92 Ohm/Km 5.41 Ohm/Km -40°C - +85 °C 51mm

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

138

Attenuation (dB/100 m) 2.2 2.9 5.0 6.1 8.9 12.8 16.8 18.6 19.6 22.2 24.8 35.5

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 0.7 0.9 1.5 1.9 2.7 3.9 5.1 5.7 6.0 6.8 7.6 10.8

www.caledonian-cables.net


50 Ohm RF Coaxial Cables ALMR500 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

n o is

Φ3.61 mm Φ9.4 mm Φ9.55 mm Φ10.3 mm Φ12.7 mm

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

& n

Min.bending radius

50±3 Ohm 77.1 pF/m 86% >5000 Mohm.Km 2.69 Ohm/Km 4.2 Ohm/Km -40°C - +85 °C 64 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

Attenuation (dB/100 m) 1.8 2.3 4.0 4.9 7.1 10.3 13.6 15.0 15.9 18.0 19.7 29.1

www.addison-cables.net

Max. Attenuation(dB/100ft) 0.5 0.7 1.2 1.5 2.2 3.1 4.1 4.6 4.8 5.5 6.0 8.9

www.addison-cables.com

139


50 Ohm RF Coaxial Cabless ALMR 600 Construction Inner conductor Dielectric Shield Outer conductor Sheath

Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

Φ4.47 mm Φ11.56 mm Φ11.71 mm Φ12.50 mm Φ14.99 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

Min.bending radius

50±3 Ohm 76.8 pF/m 87% >5000 Mohm.Km 1.7 Ohm/Km 3.9 Ohm/Km -40°C - +85 °C 75 mm

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800

140

Attenuation (dB/100 m) 1.4 1.8 3.2 3.9 5.6 8.2 10.9 12.1 12.8 14.5 15.7 23.8

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 0.4 0.5 1.0 1.2 1.7 2.5 3.3 3.7 3.9 4.4 4.8 7.3

www.caledonian-cables.net


n

50 Ohm RF Coaxial Cables 3D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid

n o is PVC/PE

Φ1.07 mm Φ3.0±0.02 mm Φ3.2 mm Φ3.6 mm 85% Φ5.4 mm

Electrical & Mechanical Characteristics

dd

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius

50±3 Ohm 82 pF/m 81% >5000 Mohm.Km 19.2(65.2) Ohm/Km 16.3 Ohm/Km -40°C - +85 °C 27 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

Attenuation (dB/100 m) 10.4 13.0 17.5 19.5 21.0 30.0 31.6 37.0 41.5 45.6 46.9 48.2 50.6 54.1

www.addison-cables.net

Attenuation (dB/100 ft) 3.2 4.0 5.3 5.9 6.4 9.1 9.6 11.3 12.6 13.9 14.3 14.7 15.4 16.5

www.addison-cables.com

141


50 Ohm RF Coaxial Cabless 5D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE

Φ1.8 mm Φ5.0±0.02 mm Φ5.2 mm Φ5.7 mm 85% Φ7.5 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius

50±3 Ohm 82 pF/m 82% >5000 Mohm.Km 6.8(10.5) Ohm/Km 14.1 Ohm/Km -40°C - +85 °C 38 mm

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

142

Attenuation (dB/100 m) 6.3 7.8 10.8 12.1 13.0 18.9 20.2 23.7 26.8 29.7 30.6 31.5 33.3 35.8

www.caledonian-cables.co.uk

Attenuation (dB/100 ft) 1.9 2.4 3.3 3.7 4.0 5.8 6.2 7.2 8.2 9.1 9.3 9.6 10.1 10.9

www.caledonian-cables.net


n

50 Ohm RF Coaxial Cables 7D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid

n o is PVC/PE

Φ2.6 mm Φ7.3±0.02 mm Φ7.5 mm Φ8.0 mm 85% Φ9.8 mm

Electrical & Mechanical Characteristics

dd

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius

50±3 Ohm 82 pF/m 82% >5000 Mohm.Km 3.3(5.0)) Ohm/Km 9.3 Ohm/Km -40°C - +85 °C 49 mm

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

Attenuation (dB/100 m) 4.3 5.3 7.3 8.3 9.0 13.1 14.2 16.7 19.0 21.2 21.8 22.5 23.8 25.7

www.addison-cables.net

Attenuation (dB/100 ft) 1.3 1.6 2.2 2.5 2.7 4.0 4.3 5.1 5.8 6.5 6.6 6.9 7.3 7.8

www.addison-cables.com

143


50 Ohm RF Coaxial Cabless 8D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(16x9x0.15mm) PVC/PE

Φ2.8 mm Φ7.8±0.02 mm Φ8.0 mm Φ8.6 mm 85% Φ10.6 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

144

50±3 Ohm 82 pF/m 84% >5000 Mohm.Km 2.4(4.4)) Ohm/Km 9.4 Ohm/Km -40°C - +85 °C 52 mm >90 dB >20 dB

Attenuation (dB/100 m) 4.1 5.1 7.1 8.1 8.7 12.9 13.8 16.3 18.6 20.8 21.5 22.1 23.5 25.4

www.caledonian-cables.co.uk

Attenuation (dB/100 ft) 1.2 1.6 2.2 2.5 2.7 3.9 4.2 5.0 5.7 6.3 6.6 6.7 7.2 7.7

www.caledonian-cables.net


n

50 Ohm RF Coaxial Cables 10D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(24x7x0.15mm)

n o is PVC/PE

Φ3.5 mm Φ10.0±0.02 mm Φ10.2 mm Φ10.8 mm 85% Φ13.0 mm

Electrical & Mechanical Characteristics

dd

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss

50±3 Ohm 84 pF/m 80% >5000 Mohm.Km 1.8(2.8)) Ohm/Km 6.4 Ohm/Km -40°C - +85 °C 65 mm >90 dB >20 dB

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

Attenuation (dB/100 m) 3.2 4.1 5.6 6.3 7.0 10.2 11.0 13.1 15.3 16.8 17.4 18.0 18.8 22.5

www.addison-cables.net

Attenuation (dB/100 ft) 1.0 1.2 1.7 1.9 2.1 3.1 3.4 4.0 4.6 5.1 5.3 5.5 5.7 6.3

www.addison-cables.com

145


50 Ohm RF Coaxial Cabless 12D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath

Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(24x7x0.15mm) PVC/PE

Φ4.4 mm Φ12.4±0.02 mm Φ12.6 mm Φ13.2 mm 85% Φ15.6 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss

50±3 Ohm 83 pF/m 81% >5000 Mohm.Km 1.2(1.8)) Ohm/Km 4.5 Ohm/Km -40°C - +85 °C 78 mm >90 dB >20 dB

n a i n

o d le

Ca

PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor

Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500

146

Attenuation (dB/100 m) 2.7 3.6 4.6 5.2 6.0 8.5 9.3 10.8 12.3 13.7 14.2 14.6 14.9 16.6

www.caledonian-cables.co.uk

Attenuation (dB/100 ft) 0.8 1.0 1.4 1.6 1.7 2.6 2.8 3.3 3.7 4.2 4.3 4.5 4.5 5.1

www.caledonian-cables.net


50 Ohm RF Coaxial Cables

& n

Semi-rigid Coaxial n Cables

o s di

d A

SR034 SR047/M17 SR086 /M17 SR086-25 SR086-75 SR090-25 SR141 SR141-25 SR141-35 SR141-75 SR250 SR250-75

www.addison-cables.net

www.addison-cables.com

147


Semi-rigid Coaxial Cabless SR034 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel(SCCS) PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, silver plated(SP)

Φ0.20 mm Φ0.66 ± 0.1 mm Φ0.86 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 3.0 mm

n a i n

o d le

Ca

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

148

Max. Attenuation(dB/100m) 112 159 362 520 752

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 34.1 48.5 110.3 158.5 229.2

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR047/M17 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.28 mm Φ0.92 ± 0.1 mm Φ1.20 ± 0.1 mm

n o is

Electrical & mechanical properties

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

50±3 Ohm 95 pF/m - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 4.2 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 79 113 259 374 544

www.addison-cables.net

Max. Attenuation(dB/100ft) 24.1 34.4 78.9 114.0 165.8

www.addison-cables.com

149


Semi-rigid Coaxial Cabless SR086 /M17 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.51 mm Φ1.67 ± 0.1 mm Φ2.20 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm

n a i n

o d le

Ca

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

150

Max. Attenuation(dB/100m) 45 64 151 222 329

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 13.7 19.5 46.0 67.7 100.3

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR086-25 Construction Inner conductor Dielectric

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Outer conductor

Φ0.92 mm Φ1.68 ± 0.1 mm Φ2.20 ± 0.1 mm

n o is

Electrical & mechanical properties

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

Nom.25 Ohm 189.6 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 59 84 197 287 423

www.addison-cables.net

Max. Attenuation(dB/100ft) 18.0 25.6 60.0 87.5 128.9

www.addison-cables.com

151


Semi-rigid Coaxial Cabless SR086-75 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.30 mm Φ1.68 ± 0.1 mm Φ2.20 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

75±5 Ohm 63 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm

n a i n

o d le

Ca

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

152

Max. Attenuation(dB/100m) 48 68 160 234 347

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 14.6 20.7 48.8 71.3 105.8

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR090-25 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ1.02 mm Φ1.85 ± 0.1 mm Φ2.20 ± 0.1 mm

n o is

Electrical & mechanical properties

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

Nom.25 Ohm 190.4 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 8.02 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 53 76 177 258 381

www.addison-cables.net

Max. Attenuation(dB/100ft) 16.2 23.2 53.9 78.6 116.1

www.addison-cables.com

153


Semi-rigid Coaxial Cabless SR141 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.93 mm Φ3.00 ± 0.1 mm Φ3.58 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

50±3 Ohm 95.1 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm

n a i n

o d le

Ca

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

154

Max. Attenuation(dB/100m) 26 38 91 137 209

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 7.9 11.6 27.7 41.8 63.7

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR141-25 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE Seamless bare copper tube

Φ1.63 mm Φ2.98 ± 0.1 mm Φ3.58 ± 0.1 mm

Electrical & mechanical properties

n o is

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

d d A

Nom.25 Ohm 190.4 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 34 48 115 170 257

www.addison-cables.net

Max. Attenuation(dB/100ft) 10.4 14.6 35.1 51.8 78.3

www.addison-cables.com

155


Semi-rigid Coaxial Cabless SR141-35 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE Seamless bare copper tube

Φ1.29 mm Φ2.98 ± 0.1 mm Φ3.68 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

Nom.35 Ohm 136 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm

o d le

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Ca

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

156

Max. Attenuation(dB/100m) 29 41 99 148 225

www.caledonian-cables.co.uk

n a i n

Max. Attenuation(dB/100ft) 8.8 12.5 30.2 45.1 68.6

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR141-75 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.51 mm Φ2.98 ± 0.1 mm Φ3.58 ± 0.1 mm

n o is

Electrical & mechanical properties

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

75±5 Ohm 68.5 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 28 40 97 145 221

www.addison-cables.net

Max. Attenuation(dB/100ft) 8.5 12.2 29.6 44.2 67.4

www.addison-cables.com

157


Semi-rigid Coaxial Cabless SR250 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ1.65 mm Φ5.31 ± 0.1 mm Φ6.35 ± 0.1 mm

Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

50±3 Ohm 95.1 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 22.3 mm

n a i n

o d le

Ca

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000

158

Max. Attenuation(dB/100m) 16 23 58 89

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 4.9 7.0 17.7 27.1

www.caledonian-cables.net


Semi-rigid Coaxial Cables SR250-75 Construction Inner conductor Dielectric Outer conductor

Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)

Φ0.94 mm Φ5.44 ± 0.1 mm Φ6.35 ± 0.1 mm

n o is

Electrical & mechanical properties

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius

& n

75±5 Ohm 63.5 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 22.3 mm

PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube

Attenuation Frequency(MHz) 500 1000 5000 10000 20000

Max. Attenuation(dB/100m) 4 24 60 93 147

www.addison-cables.net

Max. Attenuation(dB/100ft) 1.2 7.3 18.3 28.3 44.8

www.addison-cables.com

159


Semi-flexible Semi-rigid Coaxial Cabless

Semi-flexible Coaxial Cables

n a i n

SF047

o d le

SF047-FEP

SF086(Flexible RG 405)

Ca

SF086-FEP

SF141(Flexible RG 402) SF141-FEP

SF250(Flexible RG 401) SF250-FEP

160 160

www.caledonian-cables.co.uk

www.caledonian-cables.net


Semi-flexible Semi-rigid Coaxial Coaxial Cables Cables SF047 Construction Inner conductor Dielectric Outer conductor Shield coverage

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.31 mm Φ0.94 ± 0.10 mm Φ1.19 ± 0.10 mm 100%

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

& n

d d A

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 4 mm

Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

Max. Attenuation(dB/100m) 81 116 269 392 577

www.addison-cables.net

Max. Attenuation(dB/100ft) 24.7 35.4 82.0 119.5 175.9

www.addison-cables.com

161 161


Semi-flexible Coaxial Cabless SF047-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.31 mm Φ0.94 ± 0.10 mm Φ1.19 ± 0.10mm 100% Φ1.60 mm

FEP

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 4 mm

n a i n

o d le

Ca

FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

162

Max. Attenuation(dB/100m) 81 116 269 392 577

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 24.7 35.4 82.0 119.5 175.9

www.caledonian-cables.net


Semi-flexible Coaxial Cables SF086 (Flexible RG 405) Construction Inner conductor Dielectric Outer conductor Shield coverage

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.53 mm Φ1.65 ± 0.10 mm Φ2.10 ± 0.10 mm 100%

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

& n

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 6 mm

Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

Max. Attenuation(dB/100m) 46 67 160 239 361

www.addison-cables.net

Max. Attenuation(dB/100ft) 14.0 20.4 48.8 72.8 110.0

www.addison-cables.com

163


Semi-flexible Coaxial Cabless SF086-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.53 mm Φ1.65 ± 0.10 mm Φ2.10 ± 0.10 mm 100% Φ2.50 mm

FEP

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 6 mm

n a i n

o d le

Ca

FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

164

Max. Attenuation(dB/100m) 46 67 160 239 361

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 14.0 20.4 48.8 72.8 110.0

www.caledonian-cables.net


Semi-flexible Coaxial Cables SF141 (Flexible RG 402) Construction Inner conductor Dielectric Outer conductor Shield coverage

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.94 mm Φ2.95 ± 0.10 mm Φ3.58 ± 0.10 mm 100%

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

& n

50±3 Ohm 92 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.9KV -65°C - +165 °C 8 mm

Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

Max. Attenuation(dB/100m) 27 39 99 152 239

www.addison-cables.net

Max. Attenuation(dB/100ft) 8.3 11.9 30.2 46.3 72.8

www.addison-cables.com

165


Semi-flexible Coaxial Cabless SF141-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper clad steel Solid PTFE Tinned copper

Φ0.94 mm Φ2.95 ± 0.10 mm Φ3.58 ± 0.10 mm 100% Φ4.10 mm

FEP

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

50±3 Ohm 92 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.9KV -65°C - +165 °C 8 mm

n a i n

o d le

Ca

FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

166

Max. Attenuation(dB/100m) 27 39 99 152 239

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 8.3 11.9 30.2 46.3 72.8

www.caledonian-cables.net


Semi-flexible Coaxial Cables SF250 (Flexible RG 401) Construction Inner conductor Dielectric Outer conductor Shield coverage

Silver plated copper Solid PTFE Tinned copper

Φ1.67 mm Φ5.31 ± 0.10 mm Φ6.30 ± 0.10 mm 100%

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

& n

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 3.5KV -65°C - +165 °C 30 mm

Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

Max. Attenuation(dB/100m) 16 24 62 97 145

www.addison-cables.net

Max. Attenuation(dB/100ft) 4.9 7.3 18.9 29.6 44.2

www.addison-cables.com

167


Semi-flexible Coaxial Cabless SF250-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath

Silver plated copper Solid PTFE Tinned copper

Φ1.67 mm Φ5.31 ± 0.10 mm Φ6.30 ± 0.10 mm 100% Φ6.80 mm

FEP

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius

50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 3.5KV -65°C - +165 °C 30 mm

n a i n

o d le

Ca

FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube

Attenuation Frequency(GHz) 0.5 1 5 10 20

168

Max. Attenuation(dB/100m) 16 24 62 97 145

www.caledonian-cables.co.uk

Max. Attenuation(dB/100ft) 4.9 7.3 18.9 29.6 44.2

www.caledonian-cables.net


Semi-flexible Coaxial Cables

& n

50Ohm Wideband n o s Coaxial Cables i d

d A

RF42(1-5/8″) RF32(1-1/4″) RF22(7/8″) RF16(5/8″) RF12(1/2″) RF8(3/8″) RF6(1/4″)

www.addison-cables.net

www.addison-cables.com

169


Wideband Coaxial Cabless RF42(1-5/8″) Construction Inner conductor Dielectric Outer conductor Sheath

Corrugated copper tube Foam PE Corrugated copper PE/LSOH

Φ17.4 mm Φ42.8 mm Φ46.5 mm Φ49.5 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.82 Ohm/Km 0.43 Ohm/Km -40°C - +60 °C -55°C - +85°C 11 KV 1340kg/km 1 – 2700 MHz >120dB

o d le

Ca

PE/LSOH sheath Foam PE dielectric Corrugated copper tube inner conductor Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000

Attenuation (dB/100m) 0.20 0.67 0.83 0.98 1.22 1.53 1.63 1.97 2.13 2.28 2.43

Attenuation (dB/100ft) 0.06 0.20 0.25 0.30 0.37 0.47 0.50 0.60 0.65 0.69 0.74

Frequency (MHz) 1500 1700 1800 1900 2000 2100 2200 2300 2500 2700

Attenuation (dB/100m) 3.10 3.35 3.47 3.66 3.71 3.82 3.93 4.05 4.27 4.48

Return Loss 806-960 MHz 1700-2000 MHz

170

n a i n

24.3dB 24.3dB

www.caledonian-cables.co.uk

www.caledonian-cables.net

Attenuation (dB/100ft) 0.94 1.02 1.06 1.12 1.13 1.16 1.20 1.23 1.30 1.37


Wideband Coaxial Cables RF32(1-1/4″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper tube Foam PE Corrugated copper PE/LSOH

Φ13.1 mm Φ32.8 mm Φ36.0 mm Φ38.6 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

& n

d d A

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.76 Ohm/Km 0.60 Ohm/Km -40°C - +60 °C -55°C - +85°C 9 KV 940 kg/km 1 – 3300 MHz >120dB

PE/LSOH sheath Foam PE dielectric Copper tube inner conductor Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000

Attenuation (dB/100m) 0.24 0.79 0.98 1.15 1.43 1.78 1.89 2.29 2.47 2.63 2.80

Attenuation (dB/100ft) 0.08 0.26 0.33 0.38 0.48 0.59 0.63 0.76 0.82 0.88 0.93

Frequency (MHz) 1250 1500 1700 1800 2000 2100 2200 2300 2500 2700 3000

Attenuation (dB/100m) 3.19 3.55 3.83 3.96 4.22 4.34 4.47 4.59 4.83 5.06 5.40

Attenuation (dB/100ft) 1.06 1.18 1.28 1.32 1.41 1.45 1.49 1.53 1.61 1.69 1.80

Return Loss 806-960 MHz 1700-2000 MHz

www.addison-cables.net

24.29dB 24.29dB

www.addison-cables.com

171


Wideband Coaxial Cabless RF22(7/8″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper tube Foam PE Corrugated copper tube PE/LSOH

Φ9.0 mm Φ22.3 mm Φ24.9 mm Φ27.5 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

50±3 Ohm 75 pF/m 89% >5000 Mohm.Km 1.05 Ohm/Km 1.18 Ohm/Km -40°C - +60 °C -55°C - +85°C 6 KV 490 kg/km 1 – 5000 MHz >120dB

n a i n

o d le

Ca

PE/LSOH sheath Foam PE dielectric Copper tube inner conductor Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500

Attenuation (dB/100m) 0.37 1.19 1.48 1.72 2.13 2.65 2.81 3.38 3.63 3.87 4.12 5.18

Attenuation (dB/100ft) 0.11 0.36 0.45 0.52 0.65 0.81 0.86 1.03 1.11 1.18 1.26 1.58

Frequency (MHz) 1700 1800 2000 2100 2200 2300 2500 2700 3000 3400 4000 5000

Attenuation (dB/100m) 5.57 5.75 6.11 6.29 6.46 6.63 6.97 7.29 7.76 8.37 9.24 10.59

Return Loss 806-960 MHz 1700-2000 MHz

172

24.3dB 24.3dB

www.caledonian-cables.co.uk

www.caledonian-cables.net

Attenuation (dB/100ft) 1.70 1.75 1.86 1.92 1.97 2.02 2.12 2.22 2.37 2.55 2.82 3.23


Wideband Coaxial Cables RF16(5/8″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper clad Aluminium Foam PE Corrugated copper PE/LSOH

Φ7.11 mm Φ18.03 mm Φ19.81 mm Φ22.10 mm

Electrical & Mechanical Characteristics

n o is

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

& n

d d A

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.72 Ohm/Km 1.38 Ohm/Km -40°C - +60 °C -55°C - +85°C 5 KV 401 kg/km 1 – 6100 MHz >120dB

PE/LSOH sheath Foam PE dielectric Copper clad Aluminum inner conductor Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500

Attenuation (dB/100m) 0.48 1.55 1.92 2.24 2.78 3.46 3.66 4.41 4.75 5.06 5.38 6.78

Attenuation (dB/100ft) 0.15 0.47 0.59 0.68 0.85 1.05 1.12 1.34 1.45 1.54 1.64 2.07

Frequency (MHz) 1700 1800 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000

Attenuation (dB/100m) 7.29 7.54 8.02 8.25 8.48 8.70 9.15 9.57 10.20 12.14 13.94 15.63

Attenuation (dB/100ft) 2.22 2.30 2.45 2.52 2.59 2.65 2.79 2.92 3.11 3.70 4.25 4.77

Return Loss 806-960 MHz 1700-2000 MHz

www.addison-cables.net

24.3dB 24.3dB

www.addison-cables.com

173


Wideband Coaxial Cabless RF12(1/2″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper clad Aluminium Foam PE Corrugated copper PE/LSOH

Φ4.83 mm Φ12.95 mm Φ13.97 mm Φ15.88 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

Attenuation (dB/100m) 0.67 2.17 2.67 3.10 3.84 4.75 5.02 6.01 6.46 6.86 7.28 9.09 9.74

Ca

Attenuation (dB/100ft) 0.20 0.66 0.81 0.95 1.17 1.45 1.53 1.83 1.97 2.09 2.22 2.77 2.97

Frequency (MHz) 1800 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800

Attenuation (dB/100m) 10.06 10.67 10.96 11.25 11.54 12.09 12.63 13.41 15.82 18.01 20.06 23.82 25.24

Return Loss 806-960 MHz 1700-2000 MHz

174

n a i n

o d le

PE/LSOH sheath Foam PE dielectric Copper clad Aluminum inner conductor Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 1.90 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 220 kg/km 1 – 8800 MHz >120dB

24.3dB 24.3dB

www.caledonian-cables.co.uk

www.caledonian-cables.net

Attenuation (dB/100ft) 3.07 3.25 3.34 3.43 3.52 3.69 3.85 4.09 4.82 5.49 6.12 7.26 7.70


Wideband Coaxial Cables RF8(3/8″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper clad Aluminium Foam PE Corrugated copper PE/LSOH

Φ3.05 mm Φ8.64 mm Φ9.65 mm Φ11.18 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

& n

d d A

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 3.48 Ohm/Km 2.85 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 120 kg/km 1 – 13 GHz >120dB PE/LSOH sheath Copper clad Aluminum inner conductor Foam PE dielectric Corrugated copper tube

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700 1800

Attenuation (dB/100m) 1.06 3.42 4.22 4.90 6.06 7.51 7.95 9.52 10.23 10.87 11.55 14.45 15.49 15.99

Attenuation (dB/100ft) 0.32 1.04 1.29 1.49 1.85 2.29 2.42 2.90 3.12 3.31 3.52 4.41 4.72 4.88

Frequency (MHz) 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800 10000 12000

Attenuation (dB/100m) 16.97 17.44 17.91 18.37 19.26 20.12 21.38 25.26 28.81 32.12 38.24 40.55 43.89 49.21

Attenuation (dB/100ft) 5.17 5.32 5.46 5.60 5.87 6.13 6.52 7.70 8.78 9.79 11.66 12.36 13.38 15.00

Return Loss 806-960 MHz 1700-2000 MHz

www.addison-cables.net

23dB 23dB

www.addison-cables.com

175


Wideband Coaxial Cabless RF6(1/4″) Construction Inner conductor Dielectric Outer conductor Sheath

Copper clad Aluminium Foam PE Corrugated copper PE/LSOH

Φ2.54 mm Φ6.89 mm Φ7.87 mm Φ8.89 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness

Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700 1800 2000

Attenuation (dB/100m) 1.25 4.05 4.99 5.80 7.17 8.88 9.39 11.24 12.08 12.84 13.64 17.04 18.27 18.86 20.00

50±3 Ohm 76.8 pF/m 86% >5000 Mohm.Km 5.15 Ohm/Km 4.00 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 90 kg/km 1 – 15.8 GHz >120dB

n a i n

o d le

Ca

PE/LSOH sheath Copper clad Aluminum inner conductor Foam PE dielectric Corrugated copper tube

Attenuation (dB/100ft) 0.38 1.23 1.52 1.77 2.19 2.71 2.86 3.43 3.68 3.91 4.16 5.20 5.57 5.75 6.10

Frequency (MHz) 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800 10000 12000 140000 158000

Attenuation (dB/100m) 20.56 21.10 21.64 22.69 23.70 25.17 29.72 33.87 37.74 44.89 47.58 51.48 57.66 63.55 68.65

Return Loss 806-960 MHz 1700-2000 MHz

176

www.caledonian-cables.co.uk

23dB 23dB

www.caledonian-cables.net

Attenuation (dB/100ft) 6.27 6.43 6.60 6.92 7.23 7.67 9.06 10.33 11.51 13.69 14.51 15.70 17.58 19.38 20.93


Wideband Coaxial Cables

50Ohm Leaky Coaxial Cables n o

& n

s i d

d A

LCX42(1-5/8″)R LCX32(1-1/4″)R LCX22(7/8″)R LCX12(1/2″)R LCX42(1-5/8″) L LCX32(1-1/4″) L LCX22(7/8″) L LCX12(1/2″) L LCX8(3/8″) L

www.addison-cables.net

www.addison-cables.com

177


Leaky Coaxial Cabless LCX42(1-5/8″) R Construction Inner conductor Dielectric Outer conductor Sheath

Helical copper tube Foam PE Overlapping copper foil PE/LSOH

Φ17.4 mm Φ43.0 mm Φ43.8 mm Φ48.3 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.85 Ohm/Km 1.0 Ohm/Km -40°C - +60 °C -55°C - +85°C 1000kg/km/1150kg/km

n a i n

o d le

Ca

PE/LSHF sheath Physical foamed dielectric Helical copper tube inner conductor Overlapping copper foil

Attenuation Frequency(MHz) 75 150 450 800 900

178

Attenuation (dB/100 m) 0.83 0.95 1.90 2.80 3.20

www.caledonian-cables.co.uk

Attenuation (dB/100 ft) 0.25 0.29 0.58 0.85 0.98

www.caledonian-cables.net


Leaky Coaxial Cables LCX32(1-1/4″) R Construction Inner conductor Dielectric Outer conductor Sheath

Smooth copper tube Foam PE Overlapping copper foil PE/LSOH

Φ13.0mm Φ32.8 mm Φ33.6 mm Φ38.2 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

& n

d d A

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.7 Ohm/Km 1.7 Ohm/Km -40°C - +60 °C -55°C - +85°C 840kg/km/970kg/km

PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Overlapping copper foil

Attenuation Frequency(MHz) 75 150 450 800 900

Attenuation (dB/100 m) 1.00 1.35 2.30 4.00 4.35

www.addison-cables.net

Attenuation(dB/100ft) 0.30 0.41 0.70 1.22 1.33

www.addison-cables.com

179


Leaky Coaxial Cabless LCX22(7/8″) R Construction Inner conductor Dielectric Outer conductor Sheath

Smooth copper tube Foam PE Overlapping copper foil PE/LSOH

Φ9.0 mm Φ22.5 mm Φ22.8 mm Φ27.2 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

50±3 Ohm 76 pF/m 89% >5000 Mohm.Km 1.2 Ohm/Km 2.8 Ohm/Km -40°C - +60 °C -55°C - +85°C 420kg/km/480kg/km

n a i n

o d le

Ca

PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Overlapping copper foil

Attenuation Frequency(MHz) 75 150 450 800 900

180

Attenuation (dB/100 m) 1.20 1.80 3.30 5.10 5.50

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 0.37 0.55 1.01 1.55 1.68

www.caledonian-cables.net


Leaky Coaxial Cables LCX12(1/2″) R Construction Inner conductor Dielectric Outer conductor Sheath

Copper-clad Aluminium or copper Foam PE Overlapping copper foil PE/LSOH

Φ4.8 mm Φ12.3 mm Φ13.8 mm Φ15.7 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

& n

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 3.40 Ohm/Km -40°C - +60 °C -55°C - +85°C 190kg/km/230kg/km

PE/LSHF sheath Physical foamed dielectric Copper-clad AL inner conductor Overlapping copper foil

Attenuation Frequency(MHz) 150 450 800 900

Attenuation (dB/100 m) 3.3 5.9 8.4 9.1

www.addison-cables.net

Attenuation(dB/100ft) 1.01 1.80 2.56 2.77

www.addison-cables.com

181


Leaky Coaxial Cabless LCX42(1-5/8″) L Construction Inner conductor Dielectric Outer conductor Sheath

Helical copper tube Foam PE Corrugated copper tube and slot PE/LSOH

Φ17.4 mm Φ42.8 mm Φ46.5 mm Φ49.5 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.85 Ohm/Km 0.60 Ohm/Km -40°C - +60 °C -55°C - +85°C 1290kg/km/1430kg/km

n a i n

o d le

Ca

PE/LSHF sheath Physical foamed dielectric Helical copper tube inner conductor Corrugated copper tube and slot

Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400

182

Attenuation (dB/100 m) 0.6 0.8 1.9 2.6 2.7 4.4 5.1 5.5

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 0.18 0.24 0.58 0.79 0.82 1.34 1.55 1.68

www.caledonian-cables.net


Leaky Coaxial Cables LCX32(1-1/4″) L Construction Inner conductor Dielectric Outer conductor Sheath

Smooth copper tube Foam PE Corrugated copper tube and slot PE/LSOH

Φ13.0 mm Φ33.0 mm Φ36.0 mm Φ38.6 mm

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

& n

d d A

50±3 Ohm 76 pF/m 89% >5000 Mohm.Km 0.7 Ohm/Km 0.7 Ohm/Km -40°C - +60 °C -55°C - +85°C 1050kg/km/1150kg/km

PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Corrugated copper tube and slot

Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400

Attenuation (dB/100 m) 0.8 1.1 2.5 3.3 3.5 5.0 5.9 6.5

www.addison-cables.net

Attenuation(dB/100ft) 0.24 0.34 0.76 1.01 1.07 1.52 1.80 1.98

www.addison-cables.com

183


Leaky Coaxial Cabless LCX22(7/8″) L Construction Inner conductor Dielectric Outer conductor Sheath

Smooth copper tube Foam PE Corrugated copper tube and slot PE/LSOH

Φ9.0 mm Φ22.5 mm Φ24.9 mm Φ27.7 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.0 Ohm/Km 1.2 Ohm/Km -40°C - +60 °C -55°C - +85°C 520kg/km/570kg/km

n a i n

o d le

Ca

PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Corrugated copper tube and slot

Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400

184

Attenuation (dB/100 m) 1.2 1.7 3.1 4.3 4.6 4.9 7.8 8.6

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 0.37 0.52 0.95 1.31 1.40 1.49 2.38 2.62

www.caledonian-cables.net


Leaky Coaxial Cables LCX12(1/2″) L Construction Inner conductor Dielectric Outer conductor Sheath

Coppe clad Aluminium or copper Foam PE Corrugated copper tube and slot PE/LSOH

Φ4.8 mm Φ12.3 mm Φ13.8 mm Φ15.7 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

& n

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 2.10 Ohm/Km -40°C - +60 °C -55°C - +85°C 230kg/km/260kg/km

PE/LSHF sheath Physical foamed dielectric Copper clad AL inner conductor Corrugated copper tube and slot

Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400

Attenuation (dB/100 m) 2.0 2.9 5.3 7.3 7.9 12.0 13.5 14.1

www.addison-cables.net

Attenuation(dB/100ft) 0.61 0.88 1.62 2.23 2.41 3.66 4.12 4.30

www.addison-cables.com

185


Leaky Coaxial Cabless LCX8(3/8″) L Construction Inner conductor Dielectric Outer conductor Sheath

Copper clad Aluminium or copper Foam PE Corrugated copper tube and slot PE/LSOH

Φ3.1 mm Φ8.35 mm Φ9.5 mm Φ11.2 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)

50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 3.1 Ohm/Km 3.1 Ohm/Km -40°C - +60 °C -55°C - +85°C 140kg/km /160kg/km

n a i n

o d le

Ca

PE/LSHF sheath Physical foamed dielectric Copper clad AL inner conductor Corrugated copper tube and slot

Attenuation Frequency(MHz) 75 150 450 800 900 1800

186

Attenuation (dB/100 m) 3.3 4.5 7.5 10.5 11.0 15.8

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 1.01 1.37 2.29 3.20 3.35 4.82

www.caledonian-cables.net


Leaky Coaxial Cables

75Ohm Trunk Coaxial Cables n

& n

d A

o s di

AQR1125 AQR860 AQR715 AQR540 AQR320

www.addison-cables.net

www.addison-cables.com

187


Trunk Coaxial Cabless AQR1125 Construction Inner conductor Dielectric Outer conductor Sheath Messager

Copper-clad Aluminium wire Foam PE Welding solid aluminum tube PE/LSOH

Φ6.68 mm Φ25.58 mm Φ27.46 mm Φ31.12 mm optional

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)

75±5 Ohm 50 pF/m 87% >5000 Mohm.Km 0.76 Ohm/Km 0.61 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 506 kg/km

n a i n

o d le

PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube

Attenuation Frequency(MHz) 5 55 250 300 350 400 450 500 550 600 750 865 1000

Ca

Attenuation (dB/100 m) 0.23 0.76 1.77 1.94 2.13 2.30 2.46 2.62 2.76 2.96 3.31 3.64 3.94

Attenuation(dB/100ft) 0.07 0.23 0.54 0.59 0.65 0.70 0.75 0.80 0.84 0.90 1.01 1.11 1.20

Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz

188

>30dB >30dB >30dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Trunk Coaxial Cables AQR860 Construction Inner conductor Dielectric Outer conductor Sheath Messager

Copper-clad Aluminium wire Foam PE Welding smooth aluminum tube PE/LSOH

Φ5.16 mm Φ20.03 mm Φ21.84 mm Φ24.38 mm optional

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)

& n

75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 1.90 Ohm/Km 1.06 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 316 kg/km

PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube

Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000

Attenuation (dB/100 m) 0.30 1.05 2.30 2.49 2.72 2.89 3.12 3.28 3.48 3.61 4.07 4.36 4.72

Attenuation(dB/100ft) 0.09 0.32 0.70 0.76 0.83 0.88 0.95 1.00 1.06 1.10 1.24 1.33 1.44

Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz

www.addison-cables.net

>30dB >30dB >30dB

www.addison-cables.com

189


Trunk Coaxial Cabless AQR715 Construction Inner conductor Dielectric Outer conductor Sheath Messager

Copper-clad Aluminium wire Foam PE Welding smooth aluminum tube PE/LSOH

Φ4.22 mm Φ17.42 mm Φ18.16 mm Φ19.94 mm optional

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)

75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 1.91 Ohm/Km 1.37 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 215 kg/km

n a i n

o d le

PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube

Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000

Ca

Attenuation (dB/100 m) 0.36 1.18 2.66 2.92 3.18 3.44 3.67 3.90 4.10 4.30 4.89 5.31 5.74

Attenuation(dB/100ft) 0.11 0.36 0.81 0.89 0.97 1.05 1.12 1.19 1.25 1.31 1.49 1.62 1.75

Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz

190

>30dB >30dB >30dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Trunk Coaxial Cables AQR540 Construction Inner conductor Dielectric Outer conductor Sheath Messager

Copper-clad Aluminium Foam PE Welding solid aluminum tube PE/LSOH

Φ3.15 mm Φ13.05 mm Φ13.72 mm Φ15.49 mm optional

n o is

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)

& n

d d A

75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 3.43 Ohm/Km 1.92 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 136 kg/km

PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube

Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000

Attenuation (dB/100 m) 0.46 1.54 3.38 3.71 4.03 4.33 4.59 4.89 5.12 5.38 6.07 6.56 7.12

Attenuation(dB/100ft) 0.14 0.47 1.03 1.13 1.23 1.32 1.40 1.49 1.56 1.64 1.85 2.00 2.17

Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz

www.addison-cables.net

>30dB >30dB >30dB

www.addison-cables.com

191


Trunk Coaxial Cabless AQR320 Construction Inner conductor Dielectric Outer conductor Sheath Messager

Copper-clad Aluminium wire Foam PE Welding solid aluminum tube PE/Flame retardant PE

Φ1.80 mm Φ7.47 mm Φ8.13 mm Φ10.03 mm optional

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)

75±5 Ohm 50 pF/m 87% >5000 Mohm.Km 10.6 Ohm/Km 3.25 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 70 kg/km

n a i n

o d le

PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube

Attenuation Frequency(MHz) 5 55 250 300 350 400 450 500 550 600 750 865 1000

Ca

Attenuation (dB/100 m) 0.79 2.76 6.10 6.69 7.38 7.81 8.27 8.92 9.35 9.78 10.96 11.87 12.76

Attenuation(dB/100ft) 0.24 0.84 1.86 2.04 2.25 2.38 2.52 2.72 2.85 2.98 3.34 3.62 3.89

Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz

192

>30dB >30dB >30dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


Trunk Coaxial Cables

& n

BT3002 Coaxial Cables

n o is

d d A

BT3002 Single Core BT3002 8 Core BT3002 16 Core

www.addison-cables.net

www.addison-cables.com

193


BT 3002 Coaxial Cabless BT3002 Single Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper Solid PE Tinned copper braid Tinned copper braid PVC/LSOH

Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ3.55 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)

75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 28.4kg/km

n a i n

o d le

Ca

PVC sheath Tinned copper shield 1 Bare copper inner conductor Solid PE dielectric Tinned copper shield 2

Attenuation Frequency(MHz) 1 4 5 17 70 100 200

194

Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8

www.caledonian-cables.net


BT 3002 Coaxial Cables BT3002 8 Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Inner sheath Outer sheath

Bare copper Solid PE Tinned copper braid

Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ13.45 mm Φ16.0 mm

Tinned copper braid

n o is

d d A

PVC(8 x single core) PVC

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)

75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 335kg/km

BT3002 single core Reininforcement PVC sheath

Attenuation Frequency(MHz) 1 4 5 17 70 100 200

Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0

www.addison-cables.net

Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8

www.addison-cables.com

195


BT 3002 Coaxial Cabless BT3002 16 Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Inner sheath Outer sheath

Bare copper Foam/Solid PE Tinned copper braid Tinned copper braid PVC(16 x single core) PVC

Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ16.8 mm Φ21.0 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)

75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 500kg/km

n a i n

o d le

Ca

BT3002 single core

PVC sheath

Attenuation Frequency(MHz) 1 4 5 17 70 100 200

196

Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0

www.caledonian-cables.co.uk

Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8

www.caledonian-cables.net


BT 3002 Coaxial Cables

& n

CT Series Coaxial Cables n o Type s iBritish

d d A

CT 100 CT 125 CT 165

www.addison-cables.net

www.addison-cables.com

197


CT Series Coaxial Cabless CT 100 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper Foam PE Copper Foil

Φ1.00 mm Φ4.60 mm Φ4.75 mm Φ100% 96x0.10 mm 55% Φ6.55 mm

Bare copper braid PVC/LSOH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness

75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 21.4 Ohm/Km - Ohm/Km 70°C 30 V 57 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz)

n a i n

o d le

Ca

PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2

Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150

Attenuation (dB/100 m) 4.6 6.5 9.5 15.0 19.5 21.5 29.0 32.5

Attenuation (dB/100 ft) 1.40 1.98 2.90 4.57 5.95 6.55 8.84 9.91

Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz

198

>23dB >20dB >18dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


n

CT Series Coaxial Cables CT 125 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper Foam PE Copper Foil Bare copper braid

n o is

dd

PVC/LSOH

Φ1.25 mm Φ5.50 mm Φ5.65 mm 100% 96x0.10 mm 60% Φ7.80 mm

Electrical & Mechanical Characteristics

A &

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness

75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 12.8 Ohm/Km - Ohm/Km 70°C 30 V 65 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz) PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2

Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150

Attenuation (dB/100 m) 3.5 5.0 7.5 11.5 15.5 17.0 22.0 26.0

Attenuation (dB/100 ft) 1.07 1.52 2.29 3.51 4.73 5.18 6.71 7.93

Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz

www.addison-cables.net

>23dB >20dB >18dB

www.addison-cables.com

199


CT Series Coaxial Cabless CT 165 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper Foam PE Copper Foil

Φ1.63 mm Φ7.20 mm Φ7.39 mm 100% 96x0.10 mm 55% Φ10.10 mm

Bare copper braid PVC/LSOH

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness

75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 8.45 Ohm/Km - Ohm/Km 70°C 30 V 116 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz)

n a i n

o d le

Ca

PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2

Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150

Attenuation (dB/100 m) 3.0 4.0 6.0 9.0 12.5 13.5 19.0 22.0

Attenuation (dB/100 ft) 0.91 1.22 1.83 2.74 3.81 4.12 5.79 6.71

Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz

200

>23dB >20dB >18dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


CT Series Coaxial Cables

& n

TV Coaxial Cables n o Type s iFrance

d d A

19 VATC 17 VATC KX 6 KX 8

www.addison-cables.net

www.addison-cables.com

201


TV Coaxial Cabless 19 VATC Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper/Copper clad steel(CCS) Foam PE Aluminum Foil Aluminum wire braid (Type 1) Aluminum wire braid (Type 2) PVC/FR-PVC

Φ1.02 mm Φ4.60 mm Φ4.75 mm 100% 64x0.12 mm 45% 48x0.12 mm 35% Φ6.80 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Cable weight (approx.) Screening effectiveness

75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 21.4 Ohm/Km - Ohm/Km 70°C - kg/km >70 dB (5-1000MHz)

n a i n

o d le

Ca

PVC or FR-PVC sheath Aluminum foil shield 1 Bare copper inner conductor Foam PE dielectric

Attenuation

Aluminum braid shield 2

Frequency(MHz) 50 100 200 400 800 950 1350 1750 2150 3000

Attenuation (dB/100 m) 4.6 7.1 9.0 13.0 19.0 20.9 25.5 29.6 33.4 40.6

Attenuation (dB/100 ft) 1.40 2.16 2.74 3.96 5.79 6.37 7.77 9.02 10.18 12.38

Return Loss 5-1000 MHz 1000-2000 MHz

202

>22dB >20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net


TV Coaxial Cables 17 VATC Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Outer conductor (shield 2) Shield coverage 2 Sheath

Bare copper/Copper clad steel(CCS) Foam PE Aluminum Foil Aluminum wire braid (Type 1)

n o is

d d A

Aluminum wire braid (Type 2) PVC/FR-PVC

Φ1.13 mm Φ4.80 mm Φ4.95 mm 100% 64x0.12 mm 45% 48x0.12 mm 35% Φ6.80 mm

Electrical & Mechanical Characteristics

& n

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.) Screening effectiveness

75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 16.8 Ohm/Km - Ohm/Km -25°C - 75°C - kg/km >70 dB (5-1000MHz)

PVC or FR-PVC sheath Aluminum foil shield 1 Bare copper inner conductor Foam PE dielectric

Attenuation

Aluminum braid shield 2

Frequency(MHz) 50 100 200 400 800 950 1350 1750 2150 3000

Attenuation (dB/100 m) 3.7 5.5 8.1 11.7 17.0 18.7 22.8 26.4 29.8 36.2

Attenuation (dB/100 ft) 1.13 1.68 2.47 3.57 5.18 5.70 6.95 8.05 9.09 11.04

Return Loss 5-470 MHz 470-3000 MHz

www.addison-cables.net

>25dB >20dB

www.addison-cables.com

203


TV Coaxial Cabless KX 6 Construction Inner conductor Dielectric Outer conductor shield Shield coverage Sheath

Bare copper Solid PE Bare copper /Copper clad Aluminum(CCA) PVC/FR-PVC

7 x 0.2 mm Φ3.70 mm 96x0.10 mm 80% Φ10.10 mm

Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Cable weight (approx.)

75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 87.5 Ohm/Km 21.0 / 32.5 Ohm/Km 70°C - kg/km

n a i n

o d le

Ca

Bare copper outer conductor Solid PE dielectric

Bare copper inner conductor PVC or FR-PVC sheath

Attenuation

For bare copper braid Frequency Attenuation Attenuation (MHz) (dB/100 m) (dB/100 ft) 1.52 10 5.0 50 8.1 2.47 100 13.0 3.96 200 18.5 5.64 400 22.5 6.86 850 34.5 10.52 950 37.5 11.43 1000 45.0 13.72

Frequency (MHz) 50 100 200 400 850 950 -

For CCA braid Attenuation (dB/100 m) 8.1 13.0 18.5 22.5 34.5 37.5 -

Return Loss 5-1000 MHz

204

>20dB

www.caledonian-cables.co.uk

www.caledonian-cables.net

Attenuation (dB/100 ft) 2.47 3.96 5.64 6.86 10.52 11.43 -


TV Coaxial Cables KX 8 Construction Inner conductor Dielectric Outer conductor shield Shield coverage Sheath

Bare copper Solid PE Bare copper /Copper clad Aluminum(CCA) PVC/FR-PVC

7 x 0.4 mm Φ7.25 mm 192 x 0.10 mm 80% Φ10.20 mm

n o is

Electrical & Mechanical Characteristics

d d A

Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Screening effectiveness Cable weight (approx.)

& n

75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 22.2 Ohm/Km 15.5 / 16.5 Ohm/Km -25°C - 75°C 65dB(100-3000MHz) - kg/km

Bare copper outer conductor Solid PE dielectric Bare copper inner conductor PVC or FR-PVC sheath

Attenuation For bare copper braid Frequency Attenuation Attenuation (MHz) (dB/100 m) (dB/100 ft) 10 2.9 0.88 50 4.5 1.37 100 6.6 2.01 200 10.9 3.32 400 13.8 4.21 850 23.6 7.20 950 26.8 8.17 1000 27.5 8.38

Frequency (MHz) 10 50 100 200 400 850 950 1000

For CCA braid Attenuation (dB/100 m) 2.9 4.5 6.6 11.9 14.8 24.6 27.8 28.5

Attenuation (dB/100 ft) 0.88 1.37 2.01 3.63 4.51 7.50 8.48 8.69

Return Loss 5-470 MHz 470-3000 MHz

www.addison-cables.net

>25dB >20dB

www.addison-cables.com

205


TV Coaxial Cabless

Reference Notes

n a i n o d e l Ca

Ordering Code

Insulation & Sheath Material Options Amouring Options

Fire Performance Standard

206 206

www.caledonian-cables.co.uk

www.caledonian-cables.net


TV Coaxial Cables Coaxial Cables Ordering Code CCA – B-CD-EFGH-IJ A - Cable Series. FCX = FIRECOAX B - Standard RG6 = RG 6 equivalent; FRRG6 = Fire Resistant RG 6 equivalent

n o s i d d A

C - Screen Type BC = Bare Copper Braided; TC = Tinned Copper Braid; Aluminium= Aluminium/Polyester Tape; D - Screen Level 60 = 60%; 80 = 80%

& n

E- Bedding/Inner Jacket Y = PVC; 2Y = PE; H = LSOH;

F - Armouring SWA = Steel Wire Armouring; STA = Steel Tape Armouring; SWB = Steel Wire Braiding; DSTA = Double Steel Tape Armouring G - Sheathing Y = PVC; Yu = Flame Retardant PVC; Yv = PVC with reinforced sheath; 2Y = PE; H = LSOH; H - Conductor Construction 7(0.14) = 7/0.14mm I - Fire Propagation Level ( Option ) 1 = IEC 332-1; 3C = IEC 60332 = 3C; 3A = 60332-3A J - Fire Resistant Level ( Option ) 331 = IEC 331; 6386CWZ = BS 6387 CWZ

For Example: CCFCX-RG6-Aluminium100/TC61-H(SWA)H-1/0.95-3A FIRECOAX Series, RG6, 100% Aluminium/Polyester tape + 61% Tinned Copper Braid, LSOH Bedding, Steel Wire Armoured, LSOH Sheathed, 1/0.95mm, fire propagation to IEC 332-3A

www.addison-cables.net

www.addison-cables.com

207 207


Coaxial Cabless Insulation & Sheath Material Options Polyvinyl Chloride(PVC) PVC is the most widely used material throughout the cable industry because of its good mechanical and electrical properties, combined with cheap cost. The three most common materials used are PVC(-20°C to 80℃), PVC105℃(-20℃ to 105℃), PVCAF which is flame retardant (oxygen index>32% and halogen content<18 %.)

Polyethylene (PE) PE has excellent insulation characteristics and is used for data and RF transmission. It is very resistant to water penetration and thus used as sheath for outdoor/underground cables. It has three major types, ie. Low, (LDPE) medium (MDPE) and high (HDPE). Generally speaking, the higher the density, the better the mechanical performance. Cellular polyethylene has even lower Nominal capacitance than solid PE and is used for low loss data cable.

n a ni

Fluoropolymer (PTFE/FEP/PFA/ETFE)

o d le

The three most common materials used are Polytetrafluorethylene (PTFE) (-80℃ to 260℃),

Flurethylene-propylene (FEP)(-80℃ to 260℃), Polyfluoroalkoxy (PFA)(-80°C to 260°C) and Eth

Ca

ylenetetraflurorethylene(ETFE)(-80°C to 155°C),These materials are usually used in aerospace industry where wide temperature range is required.

Low Smoke Halogen Free(LSOH)

It is a flame retardant compound designed to reduce both the spread of fire and the volume of toxic gas and smoke during a fire. It is usually used in Mass Transit Railway, banking and high rise building.

208

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables Armouring Options Metallic armour are used when cables have to be installed direct buried, or if mechanical protection is required.Following points must be considered: ■■ Required tensile load ■■ Expected pressure on cable during service ■■ Protection against rodent ■■ Protection against accidental damage ■■ Minimum required bending radius

n o is

d d A SWA

& n

GSWB

SWA: single layer of galvanized steel wires, with diameters according to relevant standards, coverage min. 90%. This armour assures a very good mechanical protection and tensile strength. An additional counterspiral tape increases solidity, if required. GSWB: galvanized steel wire braid, diameter of wire: 0.20 – 0.25 – 0.30 – 0.40 mm, with coverage of > 80%. It assures a good mechanical resistance, allowing a lower bending radius compared to other armour. It is preferable when there is movement or vibration. For special application is possible to use stainless steel, tinned copper or special alloy wires.

GSTA

GSFA

GSTA: galvanized steel tape armour, composed by two tapes with overlapped edge; thickness of each tape: 0.20 – 0.30 – 0.40 mm, according to cable diameter. It grants a coverage > 100%. Very good crush resistance, but fair tensile strength. Brass tape of minimum thickness 0.075 mm can be used for special applications. GSFA: galvanized steel flat armour. It is composed by flat wire of thickness 0.6 mm or 0.8 mm, it is similar to SWA, but with higher mechanical protection.

www.addison-cables.net

www.addison-cables.com

209


Coaxial Cabless Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables.

◎ Flame Retardant

Fire retardant cables are designed for use in fire situations where the spread of flames along a cable route needs to be retarded. Due to relative low cost, fire retardant cables are widely used as fire survival cables. No matter the cables are installed in single wire or in bundles, during a fire, the flame spread will be retarded and the fire will be confined to a small area, thus reducing the fire hazard due to fire propagation.

◎ Low Smoke & Halogen Free & Fire retardant ( LSZH)

LSZH cables are not only characterized by the fire retardant performance but also by the halogen free properties, thus offering low corrosivity and toxicity. During a fire, the LSZH cables will emit less smoke and acid gases which may damage the human being and expensive equipment. Compared with normal PVC cables, LSZH cables outperform by their fire retardancy, low corrosivity and low smoke emission properties, however, normal PVC cables have better mechanical and electrical properties.

n a ni

o d le

◎ Low Smoke Fume (LSF)

The low halogen content and low corrosivity of low smoke fume cables lies somewhat in between their of fire retardant cables and LSZH cables. LSF cables also contain halogen but the content is much less than that of PVC cables. LSF cables are designed to reduce the spread of fire, toxic gases and smoke during fire. The LSF cables are usually manufactured from flame retardant PVC blended with HCL additive and smoke absorbent. These materials help improve the fire performance of the LSF cables.

◎ Fire Resistant (FR)

Ca

Fire resistant cables are designed to maintain circuit integrity of those vital emergency services during the fire. The individual conductors are wrapped with a layer of fire resisting mica/glass tape which prevents phase to phase and phase to earth contact even after the insulation has been burnt away. The fire resistant cables exhibit same performance even under fire with water spray or mechanical shock situation.

◎ Fire Performance Class

The main concerns for the cables in their fire survival properties are their flame spread, smoke characterization and gas toxicity. In American fire standard, the concern lies more on the first two and it differs from the European standard which concerns all these aspects. In USA, it is believed that the fire hazard is mainly due to CO toxic gas emitted and the heat release during the conversion of CO to CO2 during the fire. Therefore, to control the heat release is the most important concern for reducing the fire hazard. However, in European countries, halogen content, the corrosivity of the gases, the smoke density and the toxicity of the gas are equally important factors affecting the safety and survival of human during a fire.

210

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables IEC Standard for Flame Retardancy The European Electrical Committee categorizes the fire performance of the cables into three classes, namely IEC 60332-1, IEC 60332-2, IEC 60332-3. IEC 60332-1 and IEC 60332-2 are used to assess the flame propagation characteristics of a single wire. IEC 60332-3 is used to assess the flame propagation characteristics of bundled cables. Comparatively speaking, IEC 60332-3 for bundled cables is more demanding than IEC 60332-1 for single wires.

â—Ž IEC 60332-1/BS 4066-1 (Flame Test On Single Vertical Insulated Wires/Cables)

n o is

This test details a method of test for the assessment of the flame propagation characteristics of a single wire or cable. In this test, a 60cm cable sample is fixed vertically inside a metallic box and a 175mm long flame is applied at 45mm from a gas burner placed at 450mm from the top at the upper portion. The specimen is deemed to have passed this test, if after burning has ceased, the charred or affected position does not reach within 50mm of the lower edge of the top clamp which is equivalent to 425mm above the point of flame application. The test method is not suitable for the testing of some small wires due to the melting of the conductors during the time of application of the flame.

& n

d d A

â—Ž IEC 60332-3/BS 4066-3 (Flame Test On Bunched Wires/Cables) IEC60332-3C describes a method of type approval testing to define the ability of bunched cables to resist fire propagation. In this test, a cable specimen, consisting of number of 3.5m length of cables are fixed to a vertical ladder tray where they are applied with a flame from a gas burner for a specified times under controlled air flow. Four categories (A, B, C & D) are defined and distinguished by test duration and the volume of non metallic material of the sample under test. The cable specimen is deemed to have met the requirements of the standard if, after burning has ceased, the extent of charred or affected portion does not reach a height exceeding 2.5m above the bottom edge of the burner.

www.addison-cables.net

www.addison-cables.com

211


Coaxial Cabless UL Standard for Fire Retardancy ◎ CMP (Plenum Flame Test/ Steiner Tunnel Test)

Plenum rated cables meet the NFPA -262 standard (formerly known as UL910) which provides the most stringent requirement of all the tests. Cable samples on a horizontal tray in a tunnel type of chamber are burned at 87.9KW (300,000 BTU/Hr) for 20 minutes. To qualify for a plenum rating the cable specimen must have the flame spread of less than 5 feet or 1.5 meters with a smoke density during the test of (a) 0.5 peak and 0.15 maximum average. The CMP cables are usually installed in air ventilation ducts and air returns widely used in Canada and USA. The fire retardant properties of CMP cables are much better than that of normal LSZH cables complying with IEC 60332-1 and IEC 60332-3.

◎ CMR (Riser Flame Test)

Riser rated cables meets UL1666. Cable samples on a vertical shaft are burned at 154.5KW (527,500 BTU/Hr) for 30 minutes. To qualify for a riser rating, cable specimen must have the flame spread of less than 12 feet beyond the ignition point. This test does not look at the smoke density or toxicity. Riser rated cables are suitable for vertical shafts not defined as an environmental air plenum.

◎ CM (Vertical Tray Flame Test)

n a ni

o d le

General purpose cables meet UL 1581. Cable samples on a 8 feet vertical tray are burned at 20KW (70,000 BTU/Hr) for 20 minutes. The cable specimen is deemed to pass the test if the flame spread will not extend to the upper portion and extinguish by itself. UL 1581 is similar to IEC 60332-3C except for that the number of testing samples is different. This test does not look at the smoke density or toxicity. The CMG cables are usually used in runs penetrating single floor. These cables cannot be installed in vertical pathways.

Ca

◎ CMG (Vertical Tray Flame Test)

These general purpose cable also meet UL1581. CM and CMG are similar and both are recognized in Canada and USA. This test does not look at the smoke density or toxicity. The CMX cables are usually used in runs penetrating single floor. The cables cannot be installed in vertical pathways.

◎ CMX (Vertical Wire Flame Test) The restricted cables meet UL1581 Limited-use. The test consists of 25 feet long ventilated tunnel. The cable specimen is placed on a ladder inside the tunnel and the flame of 30,000 BTU/ Hr is applied to the cable 15 seconds on and 15 seconds off five times for a total exposure to the flame of 1 minute and 15 seconds. To qualify for this test, after the test flame is removed the cable specimen can flame for not more than 60 seconds and the charred portion will not exceed by 25%. UL 1581 VW-1 is similar to IEC 60332-1 except for the difference in the time for flame applied. This test does not look at the smoke density or toxicity. The CMG cables are suitable for use in dwellings and for use in raceway. These cables cannot be installed in bundles and must be protected in metal conduit. This type of cable is chosen as the minimum requirement for commercial installations.

212

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables Standard for Fire Resistance Fire resistant cables are designed for maintaining circuit integrity during a fire. The IEC and the BS adopted two different standards, namely the IEC 60331 and BS 6387.Comparatively speaking, the fire performance requirement for BS 6387 is more demanding.

◎ IEC60331 Fire Resistance Test A cable sample is placed over a gas burner and connected to an electrical supply at its rated voltage. Fire is applied for a period of 3 hours. The temperature on the cable is between 750°C and 800°C. After 3 hours, the fire and the power is switched off. 12 hours later, the cable sample is reenergized and must maintain its circuit integrity.

n o is

d d A

◎ BS6387 Fire Resistance Test

& n

BS6387 specifies the performance requirements for cables required to maintain circuit integrity under fire conditions. It details the following methods to categorize the cables according to cable withstand capacities. Resistance to fire alone - the cables is tested by gas burner flame while passing a current at its rate voltage. Four survival categories are defined Cat A (3 hours at 650°C) ,Cat B (3 hours at 750°C), Cat C (3 hours at 950°C), and Cat S (20 minutes at 950°C). Resistance to fire with water spray - a new sample of cable is exposed to flame at 650°C for 15 minutes while passing a current at its rated voltage and then the spray is turned on to give exposure to both fire and water for a further 15 minutes. A single survival category W is defined if the cables surpassed the testing requirement. Resistance to fire with mechanical shock - the final requirement is mechanical shock damage. A fresh sample is mounted on a backing panel in an S bend and is exposed to flames while the backing panel is stuck with a steel bar with the same diameter as the cables under test every 30 seconds for 15 minutes. The cables will be tested under the following temperatures: X ( 650°C/15min ), Y( 750°C/15min ) and Z ( 950°C/15min ). The highest standard for BS 6387 is CWZ.

www.addison-cables.net

www.addison-cables.com

213


Coaxial Cabless Standard for Halogen & Smoke Emission, Corrosivity & Toxicity ◎ IEC 60754-1/BS6425-1 (Emission Of Halogens) This specifies a test for determination of the amount of halogen acid gas other than the hydrofluoric acid evolved during combustion of compound based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. Halogen includes Florine, Chlorine, Bromine, Iodine and Astatine. All these elements are toxic by their nature. In this test, when the burner is heated to 800℃,1g sample is placed inside and the HCL is absorbed into water inside the chamber fed with air flow. The water is then tested with its acidity. If the hydrochloric acid yield is less than 5 mg/g, the cable specimen is categorized as LSZH. If the hydrochloric acid yield lies between 5mg/g to 15mg/g, the cable specimen is categorized as LSF. IEC60754-1 cannot be used for measuring the exact HCL yield if the yield is less than 5mg/g. This test cannot determine if the cable is 100% halogen free or not. To determine if the cable specimen is 100% halogen free or not, IEC60754-2 has to be employed.

n a ni

◎ IEC 60754-2 (Corrosivity)

o d le

This test specifies a method for the determination of degree of acidity of gases evolved during combustion of the cable specimen by measuring its pH and conductivity. The specimen is deemed to pass this test if the pH value is not less than 4.3 when related to 1 litre of water and conductivity is less than 10us/min. When the HCL yield lies between 2mg/g and 5mg/g, a cable specimen can pass IEC 60754-1 but its pH value will likely be less than 4.3 and therefore cannot pass the IEC 60754-2 test.

Ca

◎ IEC 61034-1/ASTM E662 (Emission of Smoke) This specifies a test for determination of smoke density. The 3 metre cube test measures the generation of smoke from electric cables during fire. A light beam emitted from a window is projected across the enclosure to a photo cell connected to a recorder at the opposite window. The recorder is adjusted to register from 0% for complete obscuration to 100% luminous transmissions. A 1 metre cable sample is placed in the centre of the enclosure and is applied with a fire. The minimum light transmission is recorded. The result is expressed as percentage of light transmitted. The specimen is deemed to pass this test (IEC61034-1 & 2) if the value is greater than 60% .The higher the light transmittance, the less smoke emitted during a fire.

214

www.caledonian-cables.co.uk

www.caledonian-cables.net


Coaxial Cables ◎ ISO4589-2/BS2863 (Oxygen Index LOI)

This is a test for assessing the oxygen index of the material in accordance with the test method specified in ASTM D2863-95(Measuring the minimum oxygen concentration to support candlelike combustion of plastics). At room temperature when the oxygen content in the air exceeds the oxygen index, the material will burn by itself automatically. The higher the oxygen index, the more retardant the cable will be. For example, if the oxygen index of a material is 21%, it means that the material will burn by itself even at room temperature because at room temperature the normal oxygen content is 21%. In general, the oxygen index of a LSZH cables ranges from 33% to 42%.

◎ ISO4589-3/BS2782.1 (Temperature Index TI)

n o is

This is a test for assessing the performance of a material when it is tested in accordance with BS2782 Part 1 Method 143A and 143B. The oxygen index of a material will drop when the temperature rises. When the temperature rises and the oxygen index drops to 21%, the material will burn automatically. This temperature is defined as temperature index. For example, the temperature index of coal is 50%. When the temperature climbs to 150℃, its oxygen index drop to 21% and the coal will burn by itself automatically. The temperature index of the coal will then be defined as 150℃. In general, the temperature index of LSZH cables ranges from 250℃ to 300℃.

& n

d d A

◎ ES713 (Toxicity Index)

This is a test defined by Naval Engineering Standard which is a directed at the analysis of a specified set of gaseous species which are commonly present in the combustion products of materials used in military application and which may cause lethality at the time of a fire. In this test a 1g cable specimen is completely burnt inside a sealed chambers of volume 0.7-1m3 using a burner fed with air and gas to give a non-luminous flame. The resulting chamber atmosphere is quantitatively analysed for a specified set of gases. For each gas, the measured concentration (Ci) is scaled up for 100g and the concentration is recalculated as though the combustion products is diffused into a volume of exactly 1m3. The resulting concentration (C8) is expressed as the ratio of critical factor (Cf) which is equal to the concentration of this gas considered fatal to human for 30 minutes exposure. The ratio C8/Cf are summed for all gases detected to give the toxicity index .The higher the toxicity index, the more toxic the cable materials are. In general, the toxicity index of LSZH materials are less than 5. LSZH cable will also emit toxic CO and if the cable materials contains P, N and S, the toxic gases generated will even be greater. Thus LSZH cables cannot be categorized as toxic free. CM, CMR and CMP cables in general contains halogen elements which are essential for passing the strict fire retardancy testing. For example, CMP cables are made from FEP which contains Flourine and are much toxic than normal LSZH cables.

www.addison-cables.net

www.addison-cables.com

215


Coaxial Cabless

o d le

n a ni

Ca

216

www.caledonian-cables.co.uk

www.caledonian-cables.net


Caledonian Coaxial Cables Cables Ltd Merchant Ind. Centre Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ England United Kingdom Tel: 44- 207- 4195087 Fax: 44- 207- 8319489 Email: sales@caledonian-cables.com sales@caledonian-cables.co.uk uk@addison-tech.com

& n

n o is

d d A

Addison

www.addison-cables.net

www.addison-cables.com

217


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.