Coaxial Cables
n o Coaxial Cables s i d d A & www.caledonian-cables.co.uk www.caledonian-cables.co.uk www.caledonian-cables.net www.caledonian-cables.net
www.addison-cables.net
Caledonian Caledonian
www.addison-cables.com
1
Coaxial Cabless
Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. . Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers.
n a ni
o d le
Ca
Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.
2
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables Our
& n
Certificate
n o is
d d A
www.addison-cables.net
www.addison-cables.com
3
Coaxial Cabless
Table of Content M17/RG Coaxial-Cable
MIL-C-17F 50 Ohm.............................................................................. 13 RG 8 A/U.................................................................................................. 14 M17/28-RG 58(RG 58) ............................................................................ 15 M17/155-RG 58(RG58 C/U)..................................................................... 16 M17/60-RG 142(RG 142B/U)................................................................... 17 M17/119-RG 174(RG 174A/U)................................................................. 18 M17/74-RG 213(RG 213/U)...................................................................... 19
n a ni
M17/75-RG 214(RG 214/U) . ................................................................... 20 M17/84-RG 223(RG 223/U)...................................................................... 21
M17/111-RG 303(RG 303/U).................................................................... 22
o d le
M17/112-RG 304(RG 304/U).................................................................... 23 M17/127-RG 393(RG 393/U).................................................................... 24
Ca
M17/128-RG 400(RG400/U)..................................................................... 25
MIL-C-17F 75 Ohm......................................................................... 26 M17/2 RG 6(RG 6 A/U)............................................................................. 27 M17/6-RG 11(RG 11 A/U)......................................................................... 28 M17/6-RG 12(RG 12 A/U)........................................................................ 29 M17/29-RG 59(RG 59 B/U)...................................................................... 30 M17/77-RG 216(RG216/U)....................................................................... 31 M17/110-RG 302(RG 302/U)................................................................... 32
RG Type 50 Ohm........................................................................... 33 RG 58 ER................................................................................................. 34 RG 58 CX................................................................................................. 35 RG 174 UR............................................................................................... 36 RG 213 BX............................................................................................... 37 RG 213 TY................................................................................................ 38
4
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables
& n
RG 214 PK................................................................................................ 39 RG 223 FX................................................................................................ 40 RG 223 RK............................................................................................... 41 RG 58 URM(URM 76).............................................................................. 42 RG 58 U43(URM43)................................................................................ 43 RG 213 URM(URM67)............................................................................. 44
RG Type 75 Ohm........................................................................... 45
n o is
RG 6 ....................................................................................................... 46 RG 6/U..................................................................................................... 47
d d A
RG 6/U4................................................................................................... 48
RG 6/U6................................................................................................... 49
RG 6 Quad Shield................................................................................... 50
RG 6 AX................................................................................................... 51
RG 11....................................................................................................... 52 RG 11 AL................................................................................................. 54 RG 11 AX................................................................................................. 55 RG 11 URM = URM 57............................................................................ 56 RG 59 PK................................................................................................ 57 RG 59 BX................................................................................................ 58 RF 59 LL.................................................................................................. 59 RG 59 DS................................................................................................ 60 RG 175 AF............................................................................................... 61
RG Type Low Loss 50 Ohm......................................................... 62 RF 50 LTA................................................................................................ 63 RF 195 LTA.............................................................................................. 64 RF 58 LAP............................................................................................... 65 RF 58 LTA................................................................................................ 66 RF 58 LL.................................................................................................. 67 RF 8 MINI................................................................................................ 68 RF 240 LTA.............................................................................................. 69 RF 8 LAP................................................................................................. 70
www.addison-cables.net
www.addison-cables.com
5
Coaxial Cabless RH 100.................................................................................................... 71 RH 200 INT.............................................................................................. 72 RF 400 LTA.............................................................................................. 73 RF 400 LRP............................................................................................. 74 RG 8 LRP................................................................................................ 75
Broadcast Coaxial 75 Ohm........................................................... 76 RG 59 FX................................................................................................. 77 RF 175 AF............................................................................................... 78 SLS 28810............................................................................................... 79 5 X SL 28810........................................................................................... 80 8 X SL 28810........................................................................................... 81 10 X SL 28810......................................................................................... 82
n a ni
SLS 37885............................................................................................... 83 4 X SL 37885........................................................................................... 84 5 X SL 37885........................................................................................... 85
o d le
SLS 50755............................................................................................... 86 SLS 64955............................................................................................... 87
Ca
Hybrid 75 Ohm............................................................................... 88 Twin RG 6................................................................................................ 89 Twin RG 59.............................................................................................. 90 RG175 + 3 x 0.22mm2............................................................................. 91 RG175 + 2 x 0.22mm2 + 2 x 0.5mm2....................................................... 92 RG175 + 4 x 0.22mm2 + 2 x 0.75mm2..................................................... 93 RG175 + 2 x 0.75mm2+ 10 x 0.5mm2...................................................... 94 RG59 + 2 x 0.5mm2................................................................................. 95 RG59 + 2 x 0.75mm2............................................................................... 96 RG59 + 2 x 1.00mm2............................................................................... 97 RG59 + 2 x 1.5mm2................................................................................. 98 RG59 + 2 x 0.75mm2+ 2 x 0.22mm2........................................................ 99 RG59 + 2 x 1.50mm2+ 2 x 0.25mm2...................................................... 100 RG59 + 2 x 1.50mm2+ 2 x 1.00mm2...................................................... 101 RG59 + 2 x 2.50mm2+ 2 x 0.22mm2...................................................... 102 RG59 + 2 x 0.75mm2+10x 0.50mm2...................................................... 103
6
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables Triaxial Cable Tri-RG178............................................................................................... 105 Tri-RG179............................................................................................... 106 Tri-RG180............................................................................................... 107 Tri-RG316............................................................................................... 108 Tri-RG393............................................................................................... 109
n o is
Tri-RG400................................................................................................110 Tri-RG403................................................................................................111 CTX 41....................................................................................................112
d d A
CTX 44 Flex.............................................................................................113
& n
CTX 47 Flex.............................................................................................114
CTX 64....................................................................................................115
CTX 65 Flex.............................................................................................116
CTX 80 Flex.............................................................................................117
Mininature coaxial Cable 0.81 mm Mini-Coax.................................................................................119 1.13 mm Mini-Coax................................................................................ 120 1.32 mm Mini-Coax................................................................................ 121 1.37 mm Mini-Coax................................................................................ 122 1.48 mm Mini-Coax................................................................................ 123 RG174 Mini-Coax................................................................................... 124 RG178 Mini-Coax................................................................................... 125 RGD178 Mini-Coax................................................................................ 126 RG179 Mini-Coax................................................................................... 127 RG316 Mini-Coax................................................................................... 128 RGD316 Mini-Coax................................................................................ 129 50VMTX.................................................................................................. 130 75VMTX.................................................................................................. 131
www.addison-cables.net
www.addison-cables.com
7
Coaxial Cabless 50Ohm RF Coaxial Cable ALMR100............................................................................................... 133 ALMR195............................................................................................... 134 A LMR200.............................................................................................. 135 A LMR240.............................................................................................. 136 ALMR300............................................................................................... 137 ALMR400............................................................................................... 138 ALMR500............................................................................................... 139 ALMR600............................................................................................... 140 3D-FB.................................................................................................... 141 5D-FB.................................................................................................... 142 7D-FB.................................................................................................... 143
n a ni
8D-FB.................................................................................................... 144 10D-FB................................................................................................... 145 12D-FB................................................................................................... 146
Semi-rigid Coaxial Cable
o d le
Ca
SR034..................................................................................................... 148 SR047/M17............................................................................................. 149 SR086 /M17............................................................................................ 150 SR086-25............................................................................................... 151 SR086-75............................................................................................... 152 SR090-25............................................................................................... 153 SR141..................................................................................................... 154 SR141-25............................................................................................... 155 SR141-35............................................................................................... 156 SR141-75............................................................................................... 157 SR250..................................................................................................... 158 SR250-75............................................................................................... 159
8
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables Semi-flexible Coaxial Cable SF047...................................................................................................... 161 SF047-FEP.............................................................................................. 162 SF086(Flexible RG 405).......................................................................... 163 SF086-FEP.............................................................................................. 165 SF141(Flexible RG 402).......................................................................... 165
n o is
SF141-FEP.............................................................................................. 166 SF250(Flexible RG 401).......................................................................... 167 SF250-FEP.............................................................................................. 168
d d A
50Ohm Wideband Coaxial Cable
& n
RF42(1-5/8″) ......................................................................................... 170 RF32(1-1/4″)........................................................................................... 171
RF22(7/8″).............................................................................................. 172 RF16(5/8″) ............................................................................................. 173 RF12(1/2″) ............................................................................................. 174 RF8(3/8″)................................................................................................ 175 RF6(1/4″)................................................................................................ 176
50Ohm Leaky Coaxial Cable LCX42(1-5/8″)R ...................................................................................... 178 LCX32(1-1/4″)R ...................................................................................... 179 LCX22(7/8″)R.......................................................................................... 180 LCX12(1/2″)R.......................................................................................... 181 LCX42(1-5/8″) L....................................................................................... 182 LCX32(1-1/4″) L....................................................................................... 183 LCX22(7/8″) L.......................................................................................... 184 LCX12(1/2″) L.......................................................................................... 185 LCX8(3/8″) L............................................................................................ 186
www.addison-cables.net
www.addison-cables.com
9
Coaxial Cabless 75Ohm Trunk Cable AQR1125................................................................................................ 188 AQR860.................................................................................................. 189 AQR715.................................................................................................. 190 AQR540.................................................................................................. 191 AQR320.................................................................................................. 192
BT3002 Coaxial Cable BT3002 Single Core............................................................................... 194 BT3002 8 Core....................................................................................... 195
n a ni
BT3002 16 Core..................................................................................... 196
CT Series Coaxial Cable
o d le
CT 100.................................................................................................... 198
Ca
CT 125.................................................................................................... 199 CT 165.................................................................................................... 200
TV Coaxial Cable
19 VATC.................................................................................................. 201 17 VATC.................................................................................................. 202 KX 6........................................................................................................ 203 KX 8........................................................................................................ 204
Ordering Code............................................................................................................206 Insulation & Sheath Material Options...........................................................208 Amouring Options....................................................................................................209 Fire Performance Standard.................................................................................210
10
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables The Introduction of Coaxial Cables A coaxial cable is one that consists of two conductors that share a common axis. The inner conductor is typically a straight wire, either solid or stranded and the outer conductor is typically a shield that might be braided or a foil. Coaxial cable is a cable type used to carry radio signals, video signals, measurement signals and data signals. Coaxial cables exist because we can't run open-wire line near metallic objects (such as ducting) or bury it. We trade signal loss for convenience and flexibility. Coaxial cable consists of an insulated center conductor which is covered with a shield. The signal is carried between the cable shield and the center conductor. This arrangement give quite good shielding against noise from outside cable, keeps the signal well inside the cable and keeps cable characteristics stable.
n o is
d d A
Coaxial cables and systems connected to them are not ideal. There is always some signal radiating from coaxial cable. Hence, the outer conductor also functions as a shield to reduce coupling of the signal into adjacent wiring. More shield coverage means less radiation of energy (but it does not necessarily mean less signal attenuation).
& n
Here is a quick overview of common coaxial cable impedances and their main uses:
50 Ohms:
50 ohms coaxial cable is very widely used with radio transmitter applications. It is used here because it matches nicely to many common transmitter antenna types, can quite easily handle high transmitter power and is traditionally used in this type of applications (transmitters are generally matched to 50 ohms impedance). In addition to this 50 ohm coaxial cable can be found on coaxial Ethernet networks, electronics laboratory interconnection (for example high frequency oscilloscope probe cables) and high frequency digital applications (for example ECL and PECL logic matches nicely to 50 ohms cable). Commonly used 50 Ohm constructions include RG-8 and RG-58.
75 Ohms:
The characteristic impedance 75 ohms is an international standard, based on optimizing the design of long distance coaxial cables. 75 ohms video cable is the coaxial cable type widely used in video, audio and telecommunications applications. Generally all baseband video applications that use coaxial cable (both analogue and digital) are matched for 75 ohm impedance cable. Also RF video signal systems like antenna signal distribution networks in houses and cable TV systems are built from 75 ohms coaxial cable (those applications use very low loss cable types). In audio world digital audio (S/PDIF and coaxial AES/EBU) uses 75 ohms coaxial cable, as well as radio receiver connections at home and in car. In addition to this some telecom applications (for example some E1 links) use 75 ohms coaxial cable. 75 Ohms is the telecommunications standard, because in a dielectric filled line, somewhere around 77 Ohms gives the lowest loss. For 75 Ohm use common cables are RG-6, RG-11 and RG-59.
www.addison-cables.net
www.addison-cables.com
11
Coaxial Cabless Typical coaxial cable constructions are:
RG Coaxial Cables
are used as a connection cable in the high signal sequences of wireless and data communication systems where lower attenuation required, RF and microwave transmission, data transmission and instrumentation control. Some of these cables are based upon MIL-Spec designs and are often referred to by their RG type number.MIL-C-17 is the government specification document used to standardize coaxial cables. Other impedance cables are used for data transmission and instrumentation control. 50 ohms coaxial cables are used in most radio frequency and microwave transmission, local Area Network (LAN), computer and many instrumentation /control applications.
Braided Coaxial Cable
is by far the most common type of closed transmission line because of its flexibility. It is a coaxial cable, meaning that both the signal and the ground conductors are on the same center axis. The outer conductor is made from fine braided wire, hence the name "braided coaxial cable". This type of cable is used in practically all applications requiring complete shielding of the center conductor. The effectiveness of the shielding depends upon the weave of the braid and the number of braid layers. One of the draw-backs of braided cable is that the shielding is not 100% effective, especially at higher frequencies. This is because the braided construction can permit small amounts of short wavelength (high frequency) energy to radiate. Normally this does not present a problem; however, if a higher degree of shielding is required, semirigid coaxial cable is recommended. In some high frequency flexible coaxial cables the outer shield consists if normal braids and an extra aluminium foil shield to give better high frequency shielding. Semi-rigid and Semi-flexible Coaxial Cable uses a solid tubular outer conductor, so that all the RF energy is contained within the cable, are used in wireless communication, broadcast and military equipments for transmission of radio frequency signals. For applications using frequencies higher than 30 GHz a miniature semirigid cable is recommended.
n a ni
o d le
Ca
Leaky Coaxial Cables allow radio, cellular and Wi-Fi communication in areas where free
space electromagnetic radiation typically can’t reach. These cables are used in tunnels, mines, large buildings or building complexes, alongside rail lines and in underground malls to facilitate greater wireless network coverage.
50 Ohm RF Coaxial Cables are transmission coaxial cables for GSM antennas, and the halogen-free cables are suitable for laid on hooks, and pulled through walls or through technical ducts. Trunk Cables
are used used in CATV-community antenna television, CCTV-closed-circuit television, and DBS-direct broadcasting satelite.
BT3002 Coaxial Cables
are mainly used for indoor installation in the transmission equipments for the digital telephone exchange system. Due to their miniature size, they can also be used for other applications where high performance is essential.
12
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables
& n
M17 /RG Coaxial Cables
n o is
MIL-C-17F 50Ohm
d d A
RG 8 A/U
M17/74-RG 213(RG 213/U) M17/28-RG 58(RG 58) M17/155-RG 58(RG58 C/U) M17/119-RG 174(RG 174A/U) M17/75-RG 214(RG 214/U) M17/84-RG 223(RG 223/U) M17/60-RG 142(RG 142B/U) M17/111-RG 303(RG 303/U) M17/112-RG 304(RG 304/U) M17/127-RG 393(RG 393/U) M17/128-RG 400(RG400/U)
www.addison-cables.net
www.addison-cables.com
13
MIL-C-17F Coaxial Cabless RG 8 A/U Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper
7 x 0.72 mm Φ7.25 ± 0.18 mm 192 x 0.2 mm 98% Φ10.4 ± 0.18 mm
PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Test/Operatig Voltage(max) Copper Weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 97 pF/m 66% >2000 Mohm.Km 6.2 Ohm/Km 4.0 Ohm/Km -30 °C - +70 °C 10KV/5KV 84.3 Kg/Km 171.5 Kg/Km 100-900 MHz >55dB
n a i n
o d le
Ca
Plain copper outer conductor Plain copper inner conductor Low density PE dielectric PVC or LSZH sheath
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3
Attenuation (dB/100ift) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
14
>31dB >28dB >27dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables
& n
RG 58/U Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Plain copper Low density PE Tinned copper PVC or LSZH
n o is
Φ0.80 ± 0.025 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 95% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
Nom.53±3 Ohm 94 pF/m 66% >2000 Mohm.Km 35.0 Ohm/Km 16.5 Ohm/Km 5 KV/2 KV -30 °C - +70 °C 18.7 Kg/Km 39.9 Kg/Km 100-900 MHz >55dB PVC or LSZH sheath Tinned copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 9.1 13.1 19.4 28.4 32.2 35.7 44.8 49.0
Attenuation (dB/100ft) 2.77 3.99 5.91 8.66 9.82 10.88 13.66 14.94
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>26dB >25dB >24dB
www.addison-cables.com
15
MIL-C-17F Coaxial Cabless M17/155-RG 58 (RG 58 C/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Tinned copper Low density PE Tinned copper
19 x 0.18 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 95% Φ5.00 ± 0.10 mm
PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 16.5 Ohm/Km 5 KV/2.5 KV -30 °C - +70 °C 18.7 Kg/Km 39.9 Kg/Km 100-900 MHz >55dB
n a i n
o d le
Ca
PVC or LSZH sheath
Tinned copper outer conductor
Tinned copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 10.8 16.0 24.0 37.7 41.3 49.7 64.2 70.0
Attenuation (dB/100ft) 3.29 4.88 7.32 11.49 12.59 15.15 19.57 21.34
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
16
>27dB >23dB >22dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/60-RG142 (RG 142 B/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Outer sheath
Silver plated copper clad steel(SCCS) Solid PTFE Silver plated copper
Φ0.94 mm Φ2.95 ± 0.05mm 112 x 0.13 mm 96% 112 x 0.13 mm 96% Φ4.95 mm
Silver plated copper
n o is FEP
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 95.4 pF/m 70% >2000 Mohm.Km 63.3 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C 47.0 Kg/Km 80.0 Kg/Km 100-900 MHz >60dB FEP sheath Silver copper shield1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2
Attenuation Frequency (MHz) 100 200 400 700 900 1000 2000 3000 5000 8000
Attenuation (dB/100 m) 12.8 17.7 25.9 35.1 40.4 43.0 63.3 79.4 107.0 141.7
Attenuation (dB/100ft) 3.90 5.40 7.90 10.70 12.32 13.11 19.30 24.21 32.62 43.20
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >24dB >22dB
www.addison-cables.com
17
MIL-C-17F Coaxial Cabless M17/119-RG 174 (RG 174 A/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Tinned copper PVC or LSZH
7 x 0.16 mm Φ1.50 ± 0.08 mm 64 x 0.10 mm 88% Φ2.80 ± 0.13 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 290 Ohm/Km 39.0 Ohm/Km 4.5 KV/1.6 KV -30 °C - +70 °C 5.9 Kg/Km 12.5 Kg/Km 100-900 MHz >50dB
n a i n
o d le
Ca
Tinned copper shield Copper covered steel inner conductor Low density PE dielectric PVC or LSZH sheath
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 17.5 25.8 38.2 54.9 63.1 68.6 81.2 87.5
Attenuation (dB/100ft) 5.34 7.87 11.65 16.74 19.24 20.91 24.76 26.68
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
18
>26dB >23dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/74 - RG 213 (RG 213/U) Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
n o is
7 x 0.75 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 4.5 Ohm/Km 10KV/5KV -30 °C - +70 °C 76.9 Kg/Km 163 Kg/Km 100-900 MHz >55dB Plain copper outer conductor Plain copper inner conductor Low density PE dielectric PVC or LSZH sheath
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3
Attenuation (dB/100ift) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >27dB
www.addison-cables.com
19
MIL-C-17F Coaxial Cabless M17/75-RG 214 (RG214/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Low density PE Silver plated copper Silver plated copper PVC or LSZH
7 x 0.75 mm Φ7.25 ± 0.18 mm 144 x 0.16 mm 96% 168 x 0.16 mm 98% Φ10.8 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 3.1 Ohm/Km 10.0 KV/5.0 KV -30 °C - +70 °C 117.7 Kg/Km 205.3 Kg/Km 100-900 MHz >70dB
n a i n
o d le
Ca
PVC or LSZH sheath Silvered copper shield 1 Silvered copper inner conductor Low density PE dielectric Silvered copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.7 7.1 10.4 15.2 17.4 19.2 23.9 26.2
Attenuation (dB/100ft) 1.43 2.16 3.17 4.63 5.30 5.85 7.29 7.99
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
20
>30dB >29dB >27dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/84-RG 223 (RG 223/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Low density PE Silver plated copper Silver plated copper
n o is PVC or LSZH
Φ0.90 ± 0.025 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 98% 112 x 0.13 mm 97% Φ5.40 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 8.0 Ohm/Km 5.0 KV/2.0 KV -30 °C - +70 °C 38.5 Kg/Km 59.9 Kg/Km 100-900 MHz >70dB PVC or LSZH sheath Silver copper shield1 Silver copper inner conductor Low density PE dielectric Silver copper shield2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000 3000 5000 11000
Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5 83.2 109.9 177.5
Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79 25.37 33.51 54.12
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>32dB >28dB >23dB
www.addison-cables.com
21
MIL-C-17F Coaxial Cabless M17/111-RG303 (RG303/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Silver plated copper clad steel (SCCS) PTFE Silver plated copper FEP
Φ0.94 mm Φ2.95 mm 112 x 0.13 mm 95% Φ4.32 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 63.5 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C - Kg/Km 45 Kg/Km 60 dB
n a i n
o d le
Ca
FEP sheath Silvered copper outer conductor Silvered copper clad steel inner conductor Solid PTFE dielectric
Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 1500 2000 3000
Attenuation (dB/100 m) 8.9 12.8 18.4 25.8 36.1 41.0 44.3 52.3 61.4 82.0
Attenuation (dB/100ft) 2.71 3.90 5.61 7.87 11.01 12.50 13.51 15.95 18.72 25.00
Return loss 30-300 MHz 300-600 MHz 600-900 MHz
22
>31dB >26dB >23dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/112-RG304 (RG 304/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper covered steel(SCCS) Solid PTFE Silver plated copper Silver plated copper
n o is FEP
Φ1.50 mm Φ4.75 mm 144 x 0.16 95% 144 x 0.16 95% Φ7.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 96.5 pF/m 70% >2000 Mohm.Km 36.2 Ohm/Km 4.3 Ohm/Km 5.0 KV/3.0 KV -55 °C - +200 °C -Kg/Km 130 Kg/Km 80 dB
FEP sheath Tinned copper shield 1 Silvered copper covered steel inner conductor Low density PE dielectric Tinned copper shield 2
Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 3000 5000 8000
Attenuation (dB/100 m) 5.6 8.5 13.5 18.0 24.9 27.9 30.2 56.8 77.1 114.8
Attenuation (dB/100ft) 1.71 2.59 4.12 5.49 7.59 8.51 9.21 17.32 23.51 35.00
Return loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >27dB >24dB
www.addison-cables.com
23
MIL-C-17F Coaxial Cabless M17/127-RG393 (RG 393/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Solid PTFE Silver plated copper Silver plated copper FEP
7 x 0.79 mm Φ7.25 ± 0.18 mm 144 x 0.16 mm 95% 144 x 0.16 mm 95% Φ9.90 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 4.99Ohm/Km 4.0 Ohm/Km 5.0 KV/2.5 KV -55 °C - +200 °C - Kg/Km 240 Kg/Km 80dB
n a i n
o d le
Ca
FEP sheath Silver copper shield 1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2
Attenuation Frequency (MHz) 100 200 400 900 1000 2000 3000 5000
Attenuation (dB/100 m) 6.6 9.7 14.3 22.1 24.0 34.4 47.0 65.0
Attenuation (dB/100ft) 2.01 2.96 4.36 6.74 7.32 10.49 14.33 19.82
Return loss 30-300 MHz 300-600 MHz 600-900 MHz
24
>30dB >28dB >23dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/128-RG400 (RG 400/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Solid PTFE Silver plated copper Silver plated copper
n o is FEP
19 x 0.20 mm Φ2.95 ± 0.05 mm 112 x 0.13 mm 95% 112 x 0.13 mm 94% Φ4.90 ± 0.13 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 94 pF/m 70% >2000 Mohm.Km 12.6 Ohm/Km 7.5 Ohm/Km 5.0 KV/1.9 KV -55 °C - +200 °C 46 Kg/Km 64 Kg/Km 80 dB
FEP sheath Silver copper shield1 Silver copper inner conductor Solid PTFE dielectric Silver copper shield 2
Attenuation Frequency (MHz) 50 100 200 400 900 1000 2000 3000 5000 8000
Attenuation (dB/100 m) 8.5 12.5 17.7 25.9 40.4 43.0 63.3 79.4 107.0 141.7
Attenuation (dB/100ft) 2.59 3.81 5.40 7.90 12.32 13.11 19.30 24.21 32.62 43.20
Return loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >25dB >22dB
www.addison-cables.com
25
MIL-C-17F Coaxial Cabless
M17 /RG Coaxial Cables MIL-C-17F 75Ohm
n a i n
M17/2 RG 6(RG 6 A/U)
o d le
M17/6-RG 11(RG 11 A/U)
M17/6-RG 12(RG 12 A/U)
Ca
M17/29-RG 59(RG 59 B/U) M17/77-RG 216(RG216/U)
M17/110-RG 302(RG302/U)
26
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/2-RG 6 (RG 6 A/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Silver plated copper Plain copper
n o is PVC or LSZH
Φ0.72 ± 0.025 mm Φ4.70 ± 0.10 mm 144 x 0.16 mm 97% 144 x 0.16 mm 95% Φ8.50 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 106 Ohm/Km 5.0 Ohm/Km 5.0 KV/3.0 KV -30 °C - +70 °C 46 Kg/Km 64.6 Kg/Km >70 dB
PVC or LSZH sheath Silver copper shield1 Copperweld inner conductor Low density PE dielectric Plain copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 5.8 8.5 12.5 18.0 20.3 22.6 27.5 30.4
Attenuation (dB/100ft) 1.77 2.59 3.81 5.49 6.19 6.89 8.38 9.27
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >24dB >22dB
www.addison-cables.com
27
MIL-C-17F Coaxial Cabless M17/6-RG 11 (RG11A/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Tinned copper Low density PE Plain copper
7 x 0.40 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm
PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km 8.0 KV/5.0 KV -30 °C - +70 °C 57 Kg/Km 145.2 Kg/Km >55 dB
n a i n
o d le
Ca
Plain copper shield Tinned copper inner conductor Low density PE dielectric PVC or LSZH sheath
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 20.1 23.4
Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.13 7.13
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
28
>30dB >27dB >25dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/6-RG 12 (RG12A/U) Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Inner sheath Outer conductor(shield 2) Shield coverage Outer sheath
Tinned copper Low density PE Plain copper PVC Zinc-plated steel wire(FE-ZN)
n o is
d d A
PVC or LSZH
7 x 0.40 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm 144 x 0.24 mm 85% Φ14.30 ± 0.20 mm
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km 8.0 KV/5.0 KV -30 °C - +70 °C 57 Kg/Km 298.5 Kg/Km >70 dB
FE-ZN shield 2 Low density PE dielectric Tinned copper inner conductor Plain copper shield1 PVC inner sheath PVC or LSZH outer sheath
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 21.1 23.4
Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.43 7.13
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >27dB >25dB
www.addison-cables.com
29
MIL-C-17F Coaxial Cabless M17/29-RG 59 (RG 59 B/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH
Φ0.58 ± 0.03 mm Φ3.70 ± 0.10 mm 120 x 0.15 mm 95% Φ6.20 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 9.0 Ohm/Km 5.0 KV/3.5 KV -30 °C - +70 °C 22.4 Kg/Km 55.8 Kg/Km >55 dB
n a i n
o d le
Ca
PVC or LSZH sheath Plain copper shield Copper clad steel inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
30
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
MIL-C-17F Coaxial Cables M17/77-RG 216 Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Outer sheath
Tinned copper Low density PE Plain copper Plain copper
n o is PVC or LSZH
7 x 0.40 mm Φ7.25 ± 0.18 mm 216 x 0.16 mm 97% 192 x 0.16 mm 96% Φ10.8 ± 0.18 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 3.3 Ohm/Km -30 °C - +70 °C 97.3 Kg/Km 187.0 Kg/Km >70 dB
Plain copper shield 2 Plain copper shield1 Tinned copper inner conductor Low density PE dielectric
Attenuation
PVC or LSZH sheath
Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.2 6.2 9.3 13.8 15.5 17.1 22.1 23.4
Attenuation (dB/100ft) 1.28 1.89 2.84 4.21 4.73 5.21 6.74 7.13
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >27dB >25dB
www.addison-cables.com
31
MIL-C-17F Coaxial Cabless M17/110-RG302 (RG302/U) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Silver plated copper clad steel (SCCS) PTFE Silver plated copper (0.13mm) FEP
Φ064 mm Φ3.71 mm Φ4.21 mm 90% Φ5.13 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 63.7 pF/m 70% >2000 Mohm.Km 147.5 Ohm/Km 47.5 Ohm/Km 3.5 KV/1.9 KV -55 °C - +200 °C - Kg/Km 56 Kg/Km <130 dB
n a i n
o d le
Ca
FEP sheath Silvered copper outer conductor Silvered copper clad steel inner conductor Solid PTFE dielectric
Attenuation Frequency (MHz) 50 100 200 400 700 900 1000 1500 2000 3000
32
Attenuation (dB/100 m) 6.2 12.1 17.7 24.9 36.1 34.4 38.7 44.1 52.0 70.5
www.caledonian-cables.co.uk
Attenuation (dB/100ft) 1.89 3.69 5.40 7.59 11.01 10.49 11.80 13.45 15.85 21.49
www.caledonian-cables.net
MIL-C-17F Coaxial Cables
& n
M17 /RG Coaxial Cables
n o is
RG Type 50Ohm
d d A
RG 58 ER RG 58 CX RG 174 UR RG 213 BX RG 213 TY RG 214 PK RG 223 FX RG 223 RK RG 58 URM(URM 76) RG 58 U43(URM43) RG 213 URM(URM67)
www.addison-cables.net
www.addison-cables.com
33
RG Type 50 Ohm Coaxial Cabless RG 58 ER Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
16 x 0.18 mm Φ2.85 ± 0.10 mm 80 x 0.12 mm 79% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 44 Ohm/Km 24 Ohm/Km -30 °C - +70 °C 12.4 Kg/Km 34.4 Kg/Km >50 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 9.8 14.1 20.6 30.4 34.8 38.7 47.9 52.8
Attenuation (dB/100 ft) 2.99 4.30 6.28 9.27 10.61 11.80 14.60 16.10
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
34
>26dB >25dB >22dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 50 Ohm Coaxial Cables RG 58 CX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Tinned copper Low density PE Tinned copper PVC or LSZH
n o is
19 x 0.18 mm Φ2.95 ± 0.10 mm 140 x 0.10 mm 93% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristic
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 17 Ohm/Km -30 °C - +70 °C 14.9 Kg/Km 37.1 Kg/Km >55 dB
PVC or LSZH sheath Tinned copper shield Tinned copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 9.7 13.9 20.4 30 34.2 37.9 46.9 51.8
Attenuation (dB/100 ft) 2.96 4.24 6.22 9.15 10.43 11.55 14.30 15.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>27dB >23dB >22dB
www.addison-cables.com
35
RG Type 50 Ohm Coaxial Cabless RG 174 UR Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.16 mm Φ1.50 ± 0.08 mm 64 x 0.10 mm 88% Φ2.80 ± 0.13 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 122 Ohm/Km 39 Ohm/Km -30 °C - +70 °C 6.1 Kg/Km 12.7 Kg/Km >50 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 17.7 26.0 38.5 55.3 63.6 69.2 81.9 88.3
Attenuation (dB/100 ft) 5.40 7.93 11.74 16.86 19.39 21.10 24.97 26.92
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
36
>26dB >23dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 50 Ohm Coaxial Cables RG 213 BX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
n o is
7 x 0.75 mm Φ6.50 ± 0.15 mm 168 x 0.15 mm 91% Φ9.50 ± 0.18 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6 Ohm/Km 7 Ohm/Km -30 °C - +70 °C 59.6 Kg/Km 135.1 Kg/Km >55 dB
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.8 7.2 10.5 15.4 17.6 19.5 24.2 26.5
Attenuation (dB/100 ft) 1.46 2.20 3.20 4.70 5.37 5.95 7.38 8.08
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>27dB >24dB >23dB
www.addison-cables.com
37
RG Type 50 Ohm Coaxial Cabless RG 213 TY Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.75 mm Φ7.25 ± 0.08 mm 240 x 0.13 mm 93% Φ10.3 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 5.0 Ohm/Km -30 °C - +70 °C 59.9 Kg/Km 149.7 Kg/Km >55 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 4.5 6.8 10.0 14.5 16.4 18.1 22.5 24.7
Attenuation (dB/100 ft) 1.37 2.07 3.05 4.42 5.00 5.52 6.86 7.53
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
38
>31dB >28dB >27dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 50 Ohm Coaxial Cables RG 214 PK Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Low density PE Silver plated copper
7 x 0.75 mm Φ7.25 ± 0.18 mm 168 x 0.13 mm 79% 168 x 0.13 mm 76% Φ10.8 ± 0.18 mm
Silver plated copper
n o is PVC or LSZH
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 3.8 Ohm/Km -30 °C - +70 °C 75.2 Kg/Km 167.6 Kg/Km >70 dB
PVC or LSZH sheath Silvered copper shield 1 Silvered copper inner conductor Low density PE dielectric Silvered copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.8 7.2 10.5 15.4 17.6 19.5 24.2 26.5
Attenuation (dB/100 ft) 1.46 2.20 3.20 4.70 5.37 5.95 7.38 8.08
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >29dB >27dB
www.addison-cables.com
39
RG Type 50 Ohm Coaxial Cabless RG 223 FX Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Tinned copper Low density PE Silver plated copper
19 x 0.18 mm Φ2.95 ± 0.10 mm 112 x 0.13 mm 98% 112 x 0.13 mm 97% Φ5.40 ± 0.10 mm
Silver plated copper PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 37.5 Ohm/Km 8 Ohm/Km -30 °C - +70 °C 32.7 Kg/Km 54.2 Kg/Km >70 dB
n a ni
o d
e l a
C
PVC or LSZH sheath Silvered copper shield 1 Tinned copper inner conductor Low density PE dielectric Silvered copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 9.7 13.9 20.4 30.0 34.2 37.9 46.9 51.8
Attenuation (dB/100 ft) 2.96 4.24 6.22 9.15 10.43 11.55 14.30 15.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
40
>27dB >23dB >22dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 50 Ohm Coaxial Cables RG 223 RK Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Silver plated copper Low density PE Tinned copper Tinned copper
n o is PVC or LSZH
0.9 mm Φ2.95 ± 0.10 mm 112 x 0.10 mm 85% 112 x 0.10 mm 80% Φ5.40 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 11 Ohm/Km -30 °C - +70 °C 22.7 Kg/Km 46.3 Kg/Km >70 dB
PVC or LSZH sheath Tinned copper shield 1 Silvered copper inner conductor Low density PE dielectric Tinned copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5
Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>32dB >28dB >23dB
www.addison-cables.com
41
RG Type 50 Ohm Coaxial Cabless RG 58 URM (URM76) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.32 mm Φ2.95 ± 0.10 mm 96 x 0.12 mm 86% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 32 Ohm/Km 17.5 Ohm/Km -30 °C - +70 °C 15.4 Kg/Km 36.9 Kg/Km >55 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 9.4 13.5 19.9 29.2 33.2 36.8 45.6 50.4
Attenuation (dB/100ft) 2.87 4.12 6.07 8.90 10.12 11.22 13.90 15.37
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
42
>28dB >24dB >22dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 50 Ohm Coaxial Cables RG 58 U43(URM 43) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
n o is
0.90 mm Φ2.95 ± 0.10 mm 96 x 0.15 mm 95% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 28 Ohm/Km 16.5 Ohm/Km -30 °C - +70 °C 22.1 Kg/Km 42.5 Kg/Km >55 dB
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 9.0 13.0 19.3 28.1 31.9 35.3 43.8 48.5
Attenuation (dB/100ft) 2.74 3.96 5.88 8.57 9.73 10.76 13.35 14.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>32dB >28dB >23dB
www.addison-cables.com
43
RG Type 50 Ohm Coaxial Cabless RG 213 URM (URM 67) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.75 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 98% Φ10.3 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6.0 Ohm/Km 4.0 Ohm/Km -30 °C - +70 °C 79.4 Kg/Km 165.5 Kg/Km >55 dB
n a ni
o d
e l a
C
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3
Attenuation (dB/100ft) 1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
44
>31dB >28dB >27dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
RG Type 50 Ohm Coaxial Cables
M17 /RG Coaxial Cables RG Type 75Ohm
n o is
A &
dd
RG 6
RG 6/U RG 6/U4 RG 6/U6 RG 6 Quad Shield RG 6 AX RG 11 RG 11 AL RG 11 AX RG 11 URM = URM 57 RG 59 PK RG 59 BX RF 59 LL RG 59 DS RG 175 AF
www.addison-cables.net
www.addison-cables.com
45
RG Type 75 Ohm Coaxial Cabless RG 6 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Copper clad steel (CCS) Foam PE Bonded Aluminium/Polyester Aluminium PVC or LSZH
Φ1.02 mm Φ4.57 ± 0.20 mm 100% 96 x 0.12 mm 82% Φ6.91 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 54 pF/m 83% >5000 Mohm.Km 21.7 Ohm/Km 24.1Ohm/Km -30 °C - +70 °C 45 Kg/Km
n a ni
o d
e l a
C
PVC or LSZH sheath Bonded AL/Polyester tape Copper clad steel inner conductor Foamed PE dielectric AL outer conductor
Attenuation Frequency(MHz) 50 100 200 400 700 900 1000 1350 1750 2150 2500
46
Attenuation (dB/100 m) 5.0 6.7 9.5 14.1 19.9 23.2 24.8 29.9 35.1 37.9 39.0
www.caledonian-cables.co.uk
Attenuation (dB/100ft) 1.5 2.0 2.9 4.2 6.0 7.0 7.5 9.0 10.5 11.4 11.7
www.caledonian-cables.net
n
RG Type 75 Ohm Coaxial Cables RG 6/U Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Bare copper Foam PE Aluminium foil
Φ1.02 mm Φ4.57 ± 0.20 mm 100% 96 x 0.12 mm 70% Φ7.00 ± 0.20 mm
Aluminium
n o is
dd
PVC or LSZH
Electrical & Mechanical Characteristics
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 54 pF/m 82% >5000 Mohm.Km 23.1 Ohm/Km 31Ohm/Km -30 °C - +70 °C 43 Kg/Km
PVC or LSZH sheath Bonded AL/Polyester tape Bare copper inner conductor Foamed PE dielectric AL outer conductor
Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2050 2400
Attenuation (dB/100 m) 5.0 6.4 9.2 14.5 15.9 17.7 21.9 24.9 29.0 33.1 36.4
www.addison-cables.net
Attenuation (dB/100ft) 1.5 1.96 2.8 4.4 4.9 5.4 6.7 7.6 8.8 10.1 11.1
www.addison-cables.com
47
RG Type 75 Ohm Coaxial Cabless RG 6/U4 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Bare copper Foam PE Aluminium foil
Φ1.02 mm Φ4.60 ± 0.20 mm 100% 64 x 0.12 mm 60% Φ6.80 ± 0.20 mm
Tinned copper PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 53 pF/m 83% >5000 Mohm.Km 23.1 Ohm/Km 28Ohm/Km -30 °C - +70 °C 46 Kg/Km
o d
e l a
C
n a ni
PVC or LSZH sheath Bonded AL/Polyester tape Bare copper inner conductor Foamed PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400
48
Attenuation (dB/100 m) 4.5 6.2 8.9 15.1 16.8 19.0 21.5 24.9 28.3 31.1 33.3
www.caledonian-cables.co.uk
Attenuation (dB/100ft) 1.4 1.9 2.7 4.6 5.1 5.8 6.6 7.6 8.6 9.5 10.1
www.caledonian-cables.net
n
RG Type 75 Ohm Coaxial Cables RG 6/U6 Construction Inner conductor Dielectric Tape shield(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Bare copper Foam PE Copper foil Copper
n o is
dd
PVC or LSZH
Φ1.02 mm Φ4.60 ± 0.20 mm 100% 64 x 0.12 mm 60% Φ6.80 ± 0.20 mm
Electrical & Mechanical Characteristics
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 54 pF/m 83% >5000 Mohm.Km 21.7 Ohm/Km 24.1Ohm/Km -30 °C - +70 °C 50 Kg/Km
PVC or LSZH sheath Copper foil tape Bare copper inner conductor Foamed PE dielectric Copper outer conductor
Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400
Attenuation (dB/100 m) 4.4 6.1 9.2 14.8 16.0 19.0 20.5 23.7 27.1 29.9 31.7
www.addison-cables.net
Attenuation (dB/100ft) 1.3 1.9 2.8 4.5 4.9 5.8 6.2 7.2 8.3 9.1 9.7
www.addison-cables.com
49
RG Type 75 Ohm Coaxial Cabless RG 6 Quad Shield Construction Inner conductor Dielectric Tape shield(shield 1) Braid shield(shield 2) Shield coverage Tape shield(shield 3) Braid shieldr(shield 4) Shield coverage Sheath
Copper clad steel(CCS) Foam PE Al-maylar Aluminium Al-maylar Aluminium PVC or LSZH
Φ1.02 mm Φ4.60 ± 0.20 mm ≥25% 80 x 0.12mm ≥60% ≥25% 64 x 0.12 mm ≥40% Φ7.55 ± 0.20 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 54 pF/m 82% >5000 Mohm.Km < 24.1 Ohm/Km -30 °C - +70 °C 59.8 Kg/Km
n a ni
o d
e l a
C
PVC or LSZH sheath Al-maylar shield 3
Al-maylar shield 1 Copper clad steel inner conductor Foamed PE dielectric AL braid shield 2 AL braid shield 4
Attenuation Frequency(MHz) 50 100 200 500 600 800 1000 1350 1750 2150 2400 3000
50
Attenuation (dB/100 m) 4.8 6.7 9.3 15.0 16.9 19.4 21.6 24.2 28.0 31.5 32.8 37.9
www.caledonian-cables.co.uk
Attenuation (dB/100ft) 1.5 2.0 2.8 4.6 5.1 5.9 6.6 7.4 8.4 9.6 10.0 11.5
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables RG 6 AX Construction Inner conductor Dielectric Outer conductor(shield 1) Shield coverage Outer conductor(shield 2) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Silver plated copper Plain copper
n o is PVC or LSZH
0.72 mm Φ4.70 ± 0.10 mm 168 x 0.13 mm 97% 168 x 0.13 mm 95% Φ8.50 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 106 Ohm/Km 5 Ohm/Km -30 °C - +70 °C 50.5 Kg/Km 112.4 Kg/Km >70 dB
PVC or LSZH sheath Silvered copper shield 1 Copper clad steel inner conductor Low density PE dielectric Plain copper shield 2
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 5.8 8.5 12.5 18.0 20.3 22.6 27.5 30.4
Attenuation (dB/100 m) 1.77 2.59 3.81 5.49 6.19 6.89 8.38 9.27
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >24dB >22dB
www.addison-cables.com
51
RG Type 75 Ohm Coaxial Cabless RG 11 Construction Inner conductor Dielectric Tape shield Outer conductor (shield) Shield coverage Sheath Messenger(optional)
Copper clad steel(CCS) Low density PE Aluminum foil Aluminum wire PVC or LSZH Galvanized steel
1.63 mm Φ7.2 ± 0.2 mm 100% 96 x 0.12 mm 60% Φ10.3 ± 0.18 mm 1.83mm / 2.77mm
* Tri-shield and Quad-shield are both optional ,so is the messenger Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
Attenuation Frequency(MHz) 50 100 250 300 350 400 450 500 550 600 750 860 1000 1450 2050
52
75±5 Ohm 53 pF/m 66% >2000 Mohm.Km 13.5 Ohm/Km 24.1 Ohm/Km -30 °C - +70 °C 116.4 -140.4Kg/Km
n a ni
o d
e l a
C
Attenuation (dB/100 m) 3.1 4.2 6.8 7.5 7.9 8.5 9.1 9.5 10.1 10.5 12.1 13.2 14.3 18.6 23.0
www.caledonian-cables.co.uk
Attenuation (dB/100ft) 0.95 1.28 2.07 2.29 2.41 2.59 2.77 2.90 3.08 3.20 3.69 4.02 4.36 5.67 7.01
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables
& n
PVC or LSZH sheath AL foil shield Copper clad steel inner conductor Foamed PE dielectric Tinned copper outer conductor
n o is
d d A
PVC or LSZH sheath Al foil shield 3 Al foil shield 1 Copper clad steel inner conductor Low density PE dielectric AL braid shield 2 AL braid shield 4
PVC or LSZH sheath AL foil shield Copper clad steel inner conductor Foamed PE dielectric Tinned copper outer conductor Galvanized steel messenger
www.addison-cables.net
www.addison-cables.com
53
RG Type 75 Ohm Coaxial Cabless RG 11 AL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.40 mm Φ7.25 ± 0.18 mm 112 x 0.15 mm 64% Φ10.3 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 10 Ohm/Km -30 °C - +70 °C 27.8 Kg/Km 118.2 Kg/Km >45 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 4.4 6.4 9.7 14.3 16.1 17.9 22.0 24.4
Attenuation (dB/100ft) 1.34 1.95 2.96 4.36 4.91 5.46 6.71 7.44
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
54
>30dB >27dB >25dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables RG 11 AX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
7 x 0.40 mm Φ7.25 ± 0.18 mm 240 x 0.15 mm 97% Φ10.3 ± 0.18 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 20.5 Ohm/Km 4.5 Ohm/Km -30 °C - +70 °C 49.8 Kg/Km 140.2 Kg/Km >55 dB
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.2 6.2 9.2 13.8 15.5 17.1 21.1 23.4
Attenuation (dB/100ft) 1.28 1.89 2.80 4.21 4.73 5.21 6.43 7.13
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >27dB >25dB
www.addison-cables.com
55
RG Type 75 Ohm Coaxial Cabless RG 11URM (URM 57) Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
1.15 mm Φ7.25 ± 0.18 mm 192 x 0.18 mm 97% Φ10.3 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 16.6 Ohm/Km 4.5 Ohm/Km -30 °C - +70 °C 58.3 Kg/Km 146.7 Kg/Km >55 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 3.8 5.5 8.2 12.0 13.6 15.0 18.8 20.7
Attenuation (dB/100ft) 1.16 1.68 2.50 3.66 4.15 4.57 5.73 6.31
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
56
>30dB >27dB >25dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables RG 59 PK Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH
0.58 mm Φ3.70 ± 0.10 mm 120 x 0.10 mm 77% Φ6.15 ± 0.10 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 19.5 Ohm/Km -30 °C - +70 °C 11.1 Kg/Km 45.7 Kg/Km >50 dB
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.6 11.1 16.2 23.2 26.2 29.3 35.5 38.7
Attenuation (dB/100ft) 2.32 3.38 4.94 7.07 7.99 8.93 10.82 11.80
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >24dB
www.addison-cables.com
57
RG Type 75 Ohm Coaxial Cabless RG 59 BX Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Copper clad steel(CCS) Low density PE Plain copper PVC or LSZH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11.0 Ohm/Km -30 °C - +70 °C 15.5 Kg/Km 50.9 Kg/Km >55 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation
n a ni
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.1
Attenuation (dB/100ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.62
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
58
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables RF 59 LL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Foam PE Plain copper PVC or LSZH
7 x 0.25 mm Φ3.70 ± 0.10 mm 120 x 0.15 mm 95% Φ6.15 ± 0.10 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 49 Ohm/Km 9 Ohm/Km -30 °C - +70 °C 23.8 Kg/Km 53.0 Kg/Km >55 dB
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.1 10.1 14.0 20.2 23.6 26.2 32.2 34.8
Attenuation (dB/100ft) 2.16 3.08 4.27 6.16 7.20 7.99 9.82 10.61
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>25dB >24dB >20dB
www.addison-cables.com
59
RG Type 75 Ohm Coaxial Cabless RG 59 DS Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Low densty PE Plain copper
0.6 mm Φ3.70 ± 0.10 mm 120 x 0.12 mm 86% 120 x 0.12 mm 86% Φ6.10 ± 0.10 mm
Tinned copper PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 62 Ohm/Km 8.5 Ohm/Km -25 °C - +80 °C 29.9 Kg/Km 59.8 Kg/Km >70 dB
C
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d
e l a
PVC or LSZH sheath Plain copper shield 1 Plain copper inner conductor Low density PE dielectric Tinned copper shield 2
Attenuation
n a ni
Attenuation (dB/100 m) 7.2 10.5 15.5 22.3 25.1 28.0 33.9 37.0
Attenuation (dB/100ft) 2.20 3.20 4.73 6.80 7.65 8.54 10.34 11.28
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
60
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type 75 Ohm Coaxial Cables RG 175 AF Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Foam PE Silver plated copper PVC or LSZH
9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25 °C - +80 °C 5.85 Kg/Km 12.95 Kg/Km >50 dB
PVC or LSZH sheath Silvered copper shield Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0
Attenuation (dB/100ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>20dB >20dB >20dB
www.addison-cables.com
61
RG Type 75 Ohm Coaxial Cabless
M17 /RG Coaxial Cables RG Type Low Loss 50Ohm RF 50 LTA RF 195 LTA
n a i n o d e l Ca
RF 58 LAP RF 58 LTA RF 58 LL
RF 8 MINI
RF 240 LTA RF 8 LAP RH 100
RH 200 INT RF 400 LTA RF 400 LRP RG 8 LRP
62 62
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RF 50 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Tinned copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o s i d d A PVC or LSZH
7 x 0.25 mm Φ2.00 ± 0.10 mm 100% 48 x 0.12 mm 64% Φ3.60 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 95 pF/m 75% >5000 Mohm.Km 20.5 Ohm/Km 32.5 Ohm/Km -30 °C - +70 °C 8.2 Kg/Km 18.3 Kg/Km >75 dB
PVC or LSZH sheath AL + polyester + AL tape Tinned copper inner conductor Foamed PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 13.0 17.3 35.0 43.3 52.7 57.2 76.7 94.0
Attenuation (dB/100ft) 3.96 5.27 10.67 13.20 16.07 17.44 23.38 28.66
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>24dB >21dB >15dB
www.addison-cables.com
63
RG Type Low Loss Coaxial Cabless RF 195 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC or LSZH
0.95 mm Φ2.80 ± 0.10 mm 100% 96 x 0.12 mm 85% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 25.2 Ohm/Km 18.5 Ohm/Km -30 °C - +70 °C 16.6 Kg/Km 36.6 Kg/Km >80 dB
n a i n
o d le
Ca
PVC or LSZH sheath AL + polyester + AL tape Plain copper inner conductor Foamed PE dielectric
Attenuation
Tinned copper outer conductor
Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 8.5 11.3 22.9 28.7 34.5 37.5 52.2 64.0
Attenuation (dB/100ft) 2.59 3.45 6.98 8.75 10.52 11.43 15.91 19.51
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
64
>28dB >24dB >19dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RF 58 LAP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Tinned copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is PVC or LSZH
7 x 0.40 mm Φ3.10 ± 0.10 mm 100% 96 x 0.10 mm 72% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 20.5 Ohm/Km 20 Ohm/Km -30 °C - +70 °C 15.3 Kg/Km 33.9 Kg/Km >80 dB
PVC or LSZH sheath AL + polyester + AL tape Tinned copper inner conductor Foamed PE dielectric
Attenuation
Tinned copper outer conductor
Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 9.6 12.8 25.9 32.1 39.0 42.4 59.0 72.3
Attenuation (dB/100ft) 2.93 3.90 7.90 9.79 11.89 12.93 17.99 22.04
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >24dB >22dB
www.addison-cables.com
65
RG Type Low Loss Coaxial Cabless RF 58 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper + black PE Gas injected foam PE + Carbon black PE Aluminium + polyester + Aluminium tape Tinned copper PVC or LSZH
1.00 mm Φ2.95 ± 0.10 mm 100% 64 x 0.15 mm 73% Φ5.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 20.5 Ohm/Km -30 °C - +70 °C 17.8 Kg/Km 35.4 Kg/Km >80 dB
n a i n
o d le
Ca
PVC or LSZH sheath AL + polyester + AL tape
Plain copper+black PE inner conductor Gas injected foam PE+black PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 7.3 9.8 19.7 24.9 30.1 32.7 45.8 55.8
Attenuation (dB/100ft) 2.23 2.99 6.01 7.59 9.18 9.97 13.96 17.01
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
66
>30dB >26dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RF 58 LL Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Foam PE Plain copper PVC or LSZH
7 x 0.50 mm Φ3.80 ± 0.10 mm 144 x 0.12 mm 94% Φ5.40 ± 0.10 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 14 Ohm/Km 11 Ohm/Km -30 °C - +70 °C 28.0 Kg/Km 45.9 Kg/Km >55 dB
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Foamed PE dielectric
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 7.0 10.2 21.2 26.3 32.2 35.1 48.0 58.2
Attenuation (dB/100ft) 2.13 3.11 6.46 8.02 9.82 10.70 14.63 17.74
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >27dB >22dB
www.addison-cables.com
67
RG Type Low Loss Coaxial Cabless RF 8 MINI Construction Inner conductor Dielectric Outer conductor (shield) Shield coverage Sheath
Plain copper Foam PE Plain copper
19 x 0.28 mm Φ3.90 ± 0.15 mm 128 x 0.12 mm 88% Φ6.10 ± 0.10 mm
PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 14 Ohm/Km -25 °C - +80 °C 25.2 Kg/Km 53.7 Kg/Km >55 dB
n a i n
o d le
Ca
PVC or LSZH sheath Plain copper shield Plain copper inner conductor Foamed PE dielectric
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 7.2 10.5 22.2 27.6 33.9 37.0 51.6 64.5
Attenuation (dB/100ft) 2.20 3.20 6.77 8.41 10.34 11.28 15.73 19.66
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
68
>26dB >25dB >23dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
RG Type Low Loss Coaxial Cables RF 240 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is PVC or LSZH
1.40 mm Φ3.80 ± 0.10 mm 100% 112 x 0.12 mm 80% Φ6.10 ± 0.10 mm
Electrical & Mechanical Characteristics
dd
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 11.5 Ohm/Km 14.5 Ohm/Km -30 °C - +70 °C 25.9 Kg/Km 52.6 Kg/Km >90 dB
PVC or LSZH sheath AL+polyester +ALtape Plain copper inner conductor Foamed PE dielectric
Attenuation
Tinned copper outer conductor
Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 5.7 7.8 16.2 20.0 24.2 26.0 36.0 43.1
Attenuation (dB/100ft) 1.74 2.38 4.94 6.10 7.38 7.93 10.98 13.14
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>28dB >24dB >19dB
www.addison-cables.com
69
RG Type Low Loss Coaxial Cabless RF 8 LAP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester tape Tinned copper PVC or LSZH
19 x 0.28 mm Φ3.90 ± 0.15 mm 100% 128 x 0.10 mm 80% Φ6.10 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 19 Ohm/Km -30 °C - +70 °C 20.8 Kg/Km 48.1 Kg/Km >80 dB
n a i n
o d le
Ca
PVC or LSZH sheath AL+polyester +ALtape Plain copper inner conductor Foamed PE dielectric
Attenuation
Tinned copper outer conductor
Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 7.3 9.8 19.7 24.9 30.1 32.9 45.8 55.8
Attenuation (dB/100ft) 2.23 2.99 6.01 7.59 9.18 10.03 13.96 17.01
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
70
>26dB >25dB >23dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RH 100 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Aired PE Copper + polyester tape Plain copper
n o is PVC or LSZH
2.5 mm Φ6.90 ± 0.20 mm 100% 96 x 0.12 mm 50% Φ9.70 ± 0.20 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.7 Ohm/Km 12.5 Ohm/Km -30 °C - +70 °C 61.0 Kg/Km 128.4 Kg/Km >75 dB
PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor Aired PE dielectric Plain copper outer conductor
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2
Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>25dB >22dB >18dB
www.addison-cables.com
71
RG Type Low Loss Coaxial Cabless RH 200 INT Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Tape Sheath
Plain copper Aired PE Copper + polyester tape Plain copper Non-migrating tape PVC or LSZH
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.7 Ohm/Km 5.5 Ohm/Km -40 °C - +75 °C 88.5 Kg/Km 148 Kg/Km >85 dB
100% 192 x 0.15 mm 96% h.27mm Φ10.30 ± 0.20 mm Copper + polyester tape Non-migrating tape Plain copper inner conductor Aired PE dielectric Plain copper outer conductor PVC or LSZH outer sheath
Electrical & Mechanical Characteristics
2.5 mm Φ6.90 ± 0.20 mm
n a i n
o d le
Ca
Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2
Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
72
>25dB >22dB >18dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RF 400 LTA Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Tape Sheath
Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.2 Ohm/Km 7.5 Ohm/Km -40 °C - +75 °C 71.0 Kg/Km 122.1 Kg/Km >85 dB
100% 128 x 0.15 mm 70% h.27mm Φ10.30 ± 0.18 mm
Copper + polyester tape Non-migrating tape Plain copper inner conductor Gas injected foam PE dielectric Tinned copper outer conductor PVC or LSZH outer sheath
d d A
Non-migrating tape PVC or LSZH
2.62 mm Φ7.20 ± 0.10 mm
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2
Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>29dB >26dB >24dB
www.addison-cables.com
73
RG Type Low Loss Coaxial Cabless RF 400 LRP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Gas injected foam PE Copper + polyester tape Plain copper PVC or LSZH
2.62 mm Φ7.20 ± 0.10 mm 100% 96 x 0.15 mm 56% Φ10.30 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
50±3 Ohm 80 pF/m 84% >5000 Mohm.Km 3.2 Ohm/Km 12.7 Ohm/Km -30 °C - +70 °C 71.3Kg/Km 137.7 Kg/Km >80 dB
n a i n
o d le
Ca
PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor
Gas injected foam PE dielectric Plain copper outer conductor
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 2.5 3.6 7.9 10.1 12.1 13.2 18.7 22.2
Attenuation (dB/100ft) 0.76 1.10 2.41 3.08 3.69 4.02 5.70 6.77
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
74
>29dB >26dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
RG Type Low Loss Coaxial Cables RG 8 LRP Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Low density PE Copper + polyester tape Plain copper
n o is PVC or LSZH
7 x 0.75 mm Φ7.25 ± 0.18 mm 100% 128 x 0.10 mm 57% Φ10.40 ± 0.18 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 100 pF/m 66% >2000 Mohm.Km 6 Ohm/Km 13 Ohm/Km -30 °C - +70 °C 45.3 Kg/Km 137.9 Kg/Km >80 dB
PVC or LSZH sheath Copper+polyester tape Plain copper inner conductor Low density PE dielectric Plain copper outer conductor
Attenuation Frequency(MHz) 50 100 400 600 860 1000 1750 2400
Attenuation (dB/100 m) 3.7 5.4 11.7 14.6 18.1 19.6 28.8 35.1
Attenuation (dB/100ft) 1.13 1.65 3.57 4.45 5.52 5.98 8.78 10.70
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >27dB >23dB
www.addison-cables.com
75
RG TypeBroadcast Low Loss Coaxial Coaxial Cabless Cabless Broadcast 75 Ohm RG 59 DS
M17 /RG Coaxial Cables Broadcast 75Ohm
Construction
Plain copper inner conductor 0.60 mm Low density polyethylene dielectric Φ3.70 ± 0.10 mm Plain copper Outer conductor (shield 1)20 x 0.12 mm
RG 59 FX
Shield coverage 86%
n a i n
x 0.12 Tinned copper Outer conductor (shield RF1)20 175 AF mm Shield coverage 86%
o d le
SLS 28810 sheath Φ6.10 ± 0.10 mm Grey low smoke and fume polyvinyl-chloride 5 X SL 28810 Electrical & Mechanical Characteristics 8 X SL 28810 Impedance 75 ± 3 Ohm
Nominal capacitance 67 pF/m Velocity of propagation 66%
Ca
10 X SL 28810 SLS 37885
Inner conductor resistance 62 Ohm/Km
Outer conductor resistance 8.5 Ohm/Km 4X
SL 37885
Operating temperature range -25 °C - +80 °C Cable weight (approx.) 59.8 Kg/Km
SLS 50755
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
76
5 X SL 37885
SLS 64955
Attenuation (dB/100 m) 7.2 10.5 15.5 22.3 25.1 28.0 33.9 37.1
www.caledonian-cables.co.uk
www.caledonian-cables.net
Broadcast Coaxial Cables RG 59 FX Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Plain copper Low density PE Plain copper PVC or LSZH
n o is
7 x 0.20 mm Φ3.70 ± 0.10 mm 160 x 0.10 mm 92% Φ6.20 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 82 Ohm/Km 15 Ohm/Km -30 °C - +70 °C 14.0 Kg/Km 49.4 Kg/Km >55 dB
PVC or LSZH sheath Plain copper outer conductor Plain copper inner conductor Low density PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.9 11.5 16.8 24.1 27.3 30.4 36.8 40.1
Attenuation (dB/100ft) 2.41 3.51 5.12 7.35 8.32 9.27 11.22 12.23
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >25dB >22dB
www.addison-cables.com
77
Broadcast Coaxial Cabless RF 175 AF Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Tinned copper Foam PE Tinned copper
7 x 0.13 mm Φ1.70 ± 0.10 mm 80 x 0.10 mm 92% Φ2.60 ± 0.10 mm
PVC or LSZH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 66% >5000 Mohm.Km 20.5 Ohm/Km 30.0 Ohm/Km -25 °C - +80 °C 6.9 Kg/Km 11.3 Kg/Km >50 dB
n a i n
o d le
Ca
PVC or LSZH sheath Tinned copper outer conductor Tinned copper inner conductor Foamed PE dielectric
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 11.7 15.8 24.6 36.5 41.3 44.7 53.8 57.7
Attenuation (dB/100ft) 3.57 4.82 7.50 11.13 12.59 13.63 16.40 17.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
78
>20dB >18dB >16dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Broadcast Coaxial Cables SLS 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is PVC
0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.70 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 12.2 Kg/Km 30.5 Kg/Km >85 dB
PVC sheath AL+polyester+AL tape Plain copper inner conductor Gas injected foam PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 7.3 14.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6
Attenuation (dB/100 ft) 2.23 4.48 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
www.addison-cables.net
>32dB >27dB >21dB
www.addison-cables.com
79
Broadcast Coaxial Cabless 5 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement
Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC PVC PVC
Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
PVC reinforcement
Attenuation
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 61.0 Kg/Km 192.7 Kg/Km >85 dB
80
Ca
Attenuation (dB/100 m) 7.8 15.1 23.5 32.7 35.6 41.7 44.8 48.0 54.2 57.8
Attenuation (dB/100 ft) 2.38 4.60 7.16 9.97 10.85 12.71 13.66 14.63 16.52 17.62
>32dB >27dB >23dB
www.caledonian-cables.co.uk
n a i n
o d le
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
SLS28810
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ14.20 ± 0.40 mm
PVC sheath
Electrical & Mechanical Characteristics
0.6 mm Φ2.80 ± 0.10 mm
www.caledonian-cables.net
Broadcast Coaxial Cables 8 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath
Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is
d d A
PVC PVC
0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ18.00 ± 0.80 mm
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 92.6 Kg/Km 371.6 Kg/Km >85 dB
PVC sheath SLS28810
Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 7.3 13.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6
Attenuation (dB/100 ft) 2.23 4.18 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
www.addison-cables.net
>32dB >27dB >21dB
www.addison-cables.com
81
Broadcast Coaxial Cabless 10 X SL 28810 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath
Plain copper Gas injected foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC PVC
0.6 mm Φ2.80 ± 0.10 mm 100% 128 x 0.10 mm 90% Φ4.50 ± 0.10 mm Φ22.00 ± 0.50 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 62 Ohm/Km 17.5 Ohm/Km -25 °C - +80 °C 122.0 Kg/Km 533.3 Kg/Km >85 dB
n a i n
o d le
Ca
PVC sheath SLS28810
Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 7.3 13.7 21.4 30.0 32.9 38.2 41.1 44.1 49.7 53.6
Attenuation (dB/100 ft) 2.23 4.18 6.52 9.15 10.03 11.65 12.53 13.45 15.15 16.34
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
82
>32dB >27dB >21dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
Broadcast Coaxial Cables SLS 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is PVC
0.8 mm Φ3.65 ± 0.10 mm 100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm
Electrical & Mechanical Characteristics
dd
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 21.8 Kg/Km 49.5 Kg/Km >90 dB
PVC sheath AL+polyester+AL tape Plain copper inner conductor Foamed PE dielectric Tinned copper shield
Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 6.0 12.5 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4
Attenuation (dB/100 ft) 1.83 3.81 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
www.addison-cables.net
>32dB >30dB >26dB
www.addison-cables.com
83
Broadcast Coaxial Cabless 4 X SL 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper PVC(yellow green red blue) Black PVC PVC
0.8 mm Φ3.65 ± 0.10 mm 100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm Φ16.90 ± 0.40 mm 5 x Φ2.40 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 87.2 Kg/Km 340.1 Kg/Km >90 dB
n a i n
o d le
Ca
PVC reinforcement PVC sheath SLS37885
Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 6.0 11.6 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4
Attenuation (dB/100 ft) 1.83 3.54 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
84
>32dB >30dB >26dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Broadcast Coaxial Cables 5 X SL 37885 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Individual sheath Overall sheath Reinforcement 1 Reinforcement 2
Plain copper Foam PE Aluminium + polyester + Aluminium tape
Green PVC Black PVC PVC PVC
PVC reinforcement
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 35 Ohm/Km 12.5 Ohm/Km -25 °C - +80 °C 100.0 Kg/Km 440.3 Kg/Km >90 dB
SLS37885
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
PVC sheath
Electrical & Mechanical Characteristics
& n
100% 96 x 0.15 mm 88% Φ5.90 ± 0.10 mm Φ19.40 ± 0.50 mm Φ4.20 ± 0.10 mm 5 x Φ2.30 ± 0.10 mm
Tinned copper
n o is
d d A
0.8 mm Φ3.65 ± 0.10 mm
Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 6.0 11.6 18.2 25.5 27.9 32.6 34.9 37.6 42.3 45.4
Attenuation (dB/100 ft) 1.83 3.54 5.55 7.77 8.51 9.94 10.64 11.46 12.90 13.84
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
www.addison-cables.net
>32dB >30dB >26dB
www.addison-cables.com
85
Broadcast Coaxial Cabless SLS 50755 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper Blue PVC
7 x 0.40 mm Φ4.95 ± 0.10 mm 100% 96 x 0.15 mm 71% Φ7.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 53 pF/m 84% >5000 Mohm.Km 20.5 Ohm/Km 13.5 Ohm/Km -25 °C - +80 °C 24.6 Kg/Km 56.25 Kg/Km >85 dB
n a i n
o d le
Ca
PVC sheath AL+polyester+AL tape
Plain copper inner conductor Foam PE dielectric Tinned copper shield
Attenuation Frequency(MHz) 50 230 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 4.4 9.5 13.7 19.2 21.0 24.7 26.6 28.7 32.4 34.7
Attenuation (dB/100 ft) 1.34 2.90 4.18 5.85 6.40 7.53 8.11 8.75 9.88 10.58
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
86
>30dB >26dB >22dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Broadcast Coaxial Cables SLS 64955 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Plain copper Foam PE Aluminium + polyester + Aluminium tape Tinned copper
n o is PVC
1.40 mm Φ6.4 ± 0.10 mm 100% 192 x 0.15 mm 95% Φ9.20 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
& n
75±5 Ohm 53 pF/m 84% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -25 °C - +80 °C 49.2 Kg/Km 109.2 Kg/Km >84 dB
PVC sheath AL+polyester+AL tape Plain copper inner conductor Foamed PE dielectric Tinned copper shield
Attenuation Frequency(MHz) 50 200 470 860 1000 1350 1500 1750 2150 2400
Attenuation (dB/100 m) 3.4 7.4 10.7 14.8 16.3 19.4 20.8 22.5 25.3 27.0
Attenuation (dB/100 ft) 1.04 2.26 3.26 4.51 4.97 5.91 6.34 6.86 7.71 8.23
Return Loss 30-470 MHz 470-860 MHz 860-2400 MHz
www.addison-cables.net
>29dB >27dB >23dB
www.addison-cables.com
87
Broadcast Hybrid Coaxial Cabless
M17 /RG Coaxial Cables Hybrid 75Ohm Twin RG 6
n a i n
Twin RG 59 RG175 + 3 x 0.22mm2
o d le
2
2
RG175 + 2 x 0.22mm + 2 x 0.5mm
Ca
RG175 + 4 x 0.22mm2 + 2 x 0.75mm2 RG175 + 2 x 0.75mm2+ 10 x 0.5mm2 RG59 + 2 x 0.5mm2
RG59 + 2 x 0.75mm2 RG59 + 2 x 1.00mm2 RG59 + 2 x 1.5mm2
RG59 + 2 x 0.75mm2+ 2 x 0.22mm2 RG59 + 2 x 1.50mm2+ 2 x 0.25mm2 RG59 + 2 x 1.50mm2+ 2 x 1.00mm2 RG59 + 2 x 2.50mm2+ 2 x 0.22mm2 RG59 + 2 x 0.75mm2+10x 0.50mm2
88
www.caledonian-cables.co.uk
www.caledonian-cables.net
Broadcast Coaxial Cables Hybrid Coaxial Cables Twin RG 6 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Anealed copper Foam PE Al-PES-Al foil Tinned copper
n o is PVC
Φ1.02 mm Φ4.57 mm 100% 60% Φ6.8 - 13.9mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
& n
75±5 Ohm 57 pF/m 78% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -40 °C - +70 °C 100 Kg/Km
PVC sheath AL+PES+AL foil Anealed copper inner conductor Foamed PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 200 500 860 1000 1500 2000 2400 3000
Attenuation (dB/100 m) 9.9 15.2 20.7 22.5 27.0 30.8 34.1 39.0
www.addison-cables.net
Attenuation (dB/100 ft) 3.02 4.63 6.31 6.86 8.23 9.39 10.40 11.89
www.addison-cables.com
89
Hybrid Coaxial Cabless Twin RG 59 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Outer conductor (shield 2) Shield coverage Sheath
Anealed copper Foam PE Al-PES-Al foil
0.81 mm Φ3.6 mm 100%
Tinned copper
60% Φ5.9 - 12.7mm
PVC
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.)
75±5 Ohm 57 pF/m 78% >5000 Mohm.Km 11.5 Ohm/Km 5.5 Ohm/Km -40°C - +70 °C 75 Kg/Km
PVC sheath AL+PES+AL foil
n a i n
o d le
Ca
Anealed copper inner conductor Foamed PE dielectric Tinned copper outer conductor
Attenuation Frequency(MHz) 200 500 860 1000 1500 2000 2400 3000
90
Attenuation (dB/100 m) 12.4 18.8 25.3 27.6 34.1 40.4 44.8 50.1
www.caledonian-cables.co.uk
Attenuation (dB/100 ft) 3.78 5.73 7.71 8.41 10.40 12.32 13.66 15.27
www.caledonian-cables.net
Hybrid Coaxial Cables CK175/C3:RG175AF + 3 x 0.22mm2 Construction PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor
PVC outer sheath Plain copper inner conductor PVC insulation Inner conductor1 Dielectric Outer conductor Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath
& n
Plain copper Low density PE Tinned copper
n o is
d d A
PVC Plain copper PVC(Green +Yellow + Red) PVC/LSOH
9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 3 x 0.22 mm2 3 x Φ1.00 ± 0.10 mm Φ5.30 ± 0.20 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82 Ohm/Km 1.2 KV/0.25 KV 11.85 Kg/Km 43.2 Kg/Km >50 dB
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0
Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>20dB >20dB >20dB
www.addison-cables.com
91
Hybrid Coaxial Cabless CK175/F2C2:RG175AF + 2 x 0.22mm2 + 2 x 0.5mm2 Construction
PVC overall sheath PVC insulation 3
PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor
Inner conductor 1 PVC outer sheath Dielectric Outer conductor Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
Plain copper inner conductor 3 Plain copper inner conductor 2 PVC insulation 2
Plain copper Low density PE Tinned copper
9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm 2 x 0.50 mm2 2 x Φ1.50 ± 0.10 mm Φ6.20 ± 0.20 mm
PVC Plain copper PVC Plain copper PVC PVC
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 - 0.50 mm2 Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
n a i n
o d le
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82Ohm/Km - 39 Ohm/Km 1.2 KV/0.25 KV 18.85 Kg/Km 61.55 Kg/Km >50 dB
Ca
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0
Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
92
>20dB >20dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Hybrid Coaxial Cables CK175/H2C4:RG175AF + 4 x 0.22mm2 + 2 x 0.75mm2 Construction
PVC overall sheath PVC insulation 2
PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor
Inner conductor 1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
& n
Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3
Plain copper Low density PE Tinned copper
d d A
n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH
9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 4 x 0.22 mm2 4 x Φ1.00 ± 0.10 mm 2 x 0.75 mm2 2 x Φ1.70 ± 0.10 mm Φ7.00 ± 0.20 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2/ 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 82Ohm/Km/26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 27.45 Kg/Km 82.75 Kg/Km >50 dB
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0
Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz www.addison-cables.net
>20dB >20dB >20dB www.addison-cables.com
93
Hybrid Coaxial Cabless CK175/H2F10:RG175AF + 2 x 0.75mm2+ 10 x 0.5mm2 Construction
PVC insulation 2 Plain copper inner conductor 2
PVC outer sheath Plain copper inner conductor Low density PE dielectric Tinned copper outer conductor
Inner conductor 1 Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
PVC insulation 3 Plain copper inner conductor 3
Copper covered steel(CCS) Low density PE Tinned copper PVC Plain copper PVC Plain copper PVC PVC/LSOH
9 x 0.10 mm Φ1.50 ± 0.08 mm 72 x 0.10 mm 90% Φ2.80 ± 0.13 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 10 x 0.5 mm2 10 x Φ1.50 ± 0.10 mm Φ9.90 ± 0.30 mm
n a i n
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.50 mm2/0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 250 Ohm/Km 35 Ohm/Km -25°C - +80 °C 39Ohm/Km/26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 64.45 Kg/Km 172.65 Kg/Km >50 dB
o d le
Ca
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 19.2 27.9 40.7 59.2 67.5 72.6 91.1 101.0
Attenuation (dB/100 ft) 5.85 8.51 12.41 18.05 20.58 22.13 27.77 30.79
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
94
>20dB >20dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
Hybrid Coaxial Cables CK 059/F2:RG59BX + 2 x 0.5mm2 Construction Inner conductor1 Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH
dd
n o is
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 0.50 mm2 2 x Φ1.50 ± 0.10 mm Φ10.30 ± 0.30 mm
Electrical & Mechanical Characteristics
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
Attenuation
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 39 Ohm/Km 1.2 KV/0.25 KV 24.5 Kg/Km 142.8 Kg/Km >55 dB PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
PVC overall sheath PVC insulation Plain copper inner conductor
Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >24dB
www.addison-cables.com
95
Hybrid Coaxial Cabless CK 059/H2:RG59BX + 2 x 0.75mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 0.75 mm2 2 x Φ1.70 ± 0.10 mm Φ10.30 ± 0.30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
Attenuation
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 26 Ohm/Km 2 KV/0.3 KV 29.1 Kg/Km 147.6 Kg/Km >55 dB
Frequency(MHz) 50 100 200 400 500 600 860 1000
o d le
Ca
PVC overall sheath PVC insulation Plain copper inner conductor
n a i n
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
96
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
Hybrid Coaxial Cables CK 059/K2:RG59BX + 2 x 1.00mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH
n o is
dd
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 1.00 mm2 2 x Φ2.40 ± 0.10 mm Φ10.90 ± 0.30 mm
Electrical & Mechanical Characteristics
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 18 Ohm/Km 2 KV/0.3 KV 33.5 Kg/Km 166.0 Kg/Km >55 dB
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
PVC overall sheath PVC insulation Plain copper inner conductor
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz www.addison-cables.net
>31dB >28dB >24dB www.addison-cables.com
97
Hybrid Coaxial Cabless CK 059/M2:RG59BX + 2 x 1.50mm2 Construction Inner conductor1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Overall sheath
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2 x 1.50 mm2 2 x Φ2.60 ± 0.10 mm Φ11.490 ± 0.30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance Test/Operatig Voltage(max) Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 12 Ohm/Km 2 KV/0.3 KV 42.1 Kg/Km 186.9 Kg/Km >55 dB
PVC overall sheath PVC insulation Plain copper inner conductor
o d le
Ca
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
n a i n
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
98
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Hybrid Coaxial Cables CK 059/H2C2:RG59BX + 2 x 0.75mm2+ 2 x 0.22mm2 PVC overall sheath PVC insulation 2
Construction PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Inner conductor 1 PVC outer sheath Dielectric Outer conductor (shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
& n
Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3
Copper covered steel(CCS) Low density PE Plain copper
n o is
d d A
PVC Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm Φ10.40 ± 0.30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 / 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 82 Ohm/Km /26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 33.1 Kg/Km 153.4 Kg/Km >55 dB
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >24dB
www.addison-cables.com
99
Hybrid Coaxial Cabless CK 059/M2D2:RG59BX + 2 x 1.5mm2+ 2 x 0.25mm2 PVC overall sheath PVC insulation 2
Construction PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Inner conductor 1 Dielectric PVC outer sheath Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 1.5 mm2 2 xΦ2.60 ± 0.10 mm 2 x 0.25 mm2 2 x Φ1.15 ± 0.10 mm Φ10.90 ± 0.30 mm
n a i n
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.25 mm2 /1.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 75 Ohm/Km / 12 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 33.1 Kg/Km 153.4 Kg/Km >55 dB
o d le
Ca
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
100
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Hybrid Coaxial Cables CK 059/M2K2:RG59BX + 2 x 1.5mm2+ 2 x 1.00mm2 Construction
PVC overall sheath PVC insulation 2
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Inner conductor 1 sheath PVC outer Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
& n
Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3
Copper covered steel(CCS) Low density PE Plain copper
d d A
n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 1.50 mm2 2 x Φ2.60 ± 0.10 mm 2 x 1.00 mm2 2 x Φ1.70 ± 0.10 mm Φ12.00 ± 0.30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 1.00 mm2 / 1.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 18 Ohm/Km/12 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 60.1 Kg/Km 220.7 Kg/Km >55 dB
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >24dB
www.addison-cables.com
101
Hybrid Coaxial Cabless CK 059/S2C2:RG59BX + 2 x 2.5mm2+ 2 x 0.22mm2 Construction
PVC overall sheath PVC insulation 2
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Inner conductor 1 PVC outer sheath Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
Plain copper inner conductor 2 Plain copper inner conductor 3 PVC insulation 3
Copper covered steel(CCS) Low density PE Plain copper PVC Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 2.50 mm2 2 x Φ3.40 ± 0.10 mm 2 x 0.22 mm2 2 x Φ1.00 ± 0.10 mm Φ12.00 ± 0.30 mm
n a i n
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.22 mm2 / 2.50 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 82 Ohm/Km/8 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 63.5 Kg/Km 221.4 Kg/Km >55 dB
o d le
Ca
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
102
>31dB >28dB >24dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Hybrid Coaxial Cables CK 059/H2F10:RG59BX + 2 x 0.75mm2+ 10 x 0.5mm2 Construction
PVC insulation 2 Plain copper inner conductor 2
PVC outer sheath Copperweld inner conductor Low density PE dielectric Plain copper outer conductor
Inner conductor 1 Dielectric Outer conductor(shield) Shield coverage Sheath Inner conductor 2 Insulated cores 2 Inner conductor 3 Insulated cores 3 Overall sheath
& n
PVC insulation 3 Plain copper inner conductor 3
Copper covered steel(CCS) Low density PE Plain copper
d d A
n o is PVC Plain copper PVC Plain copper PVC PVC/LSOH
0.58 mm Φ3.70 ± 0.10 mm 180 x 0.10 mm 94% Φ6.20 ± 0.10 mm 2x 0.75 mm2 2 x Φ1.70 ± 0.10 mm 10 x 0.50 mm2 10 x Φ1.50 ± 0.10 mm Φ12.80 ± 0.30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cores resistance 0.50 mm2 - 0.75 mm2 Operatig Voltage(max) Test Voltage Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 67 pF/m 66% >2000 Mohm.Km 158 Ohm/Km 11 Ohm/Km -25°C - +80 °C 39 Ohm/Km - 26 Ohm/Km 0.25 KV/0.3 KV 1.2 KV/2.0 KV 74.1 Kg/Km 254.9 Kg/Km >55 dB
Attenuation Frequency(MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 7.4 10.7 15.7 22.7 25.7 28.7 34.8 38.0
Attenuation (dB/100 ft) 2.26 3.26 4.79 6.92 7.84 8.75 10.61 11.59
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>31dB >28dB >24dB
www.addison-cables.com
103
Triaxial Cabless Hybrid Coaxial
Triaxial Cables Tri-RG178 Tri-RG179
n a i n
Tri-RG180
o d le
Tri-RG316 Tri-RG393
Ca
Tri-RG400 Tri-RG403 CTX 41
CTX 44 Flex CTX 47 Flex CTX 64 CTX 65 Flex CTX 80 Flex
104
www.caledonian-cables.co.uk
www.caledonian-cables.net
TriaxialCoaxial Cables Cables Hybrid Tri-RG178 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper FEP Silver plated copper FEP
n o is
7 x 0.10 mm Φ0.86 ± 0.10 mm Φ1.26 ± 0.10 mm Φ1.80 ± 0.10 mm Φ2.20 ± 0.10 mm Φ2.85 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
& n
50±5 Ohm 96.5 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 1 KV -55°C - +200 °C 24 Kg/Km >60 dB
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 400 1000 3000
Attenuation (dB/100 m) 45.3 91.2 145.7 257.2
www.addison-cables.net
Max. Attenuation(dB/100ft) 13.8 27.8 44.4 78.4
www.addison-cables.com
105
Triaxial Cabless Tri-RG179 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.1mm) FEP
7 x 0.10 mm Φ1.60 ± 0.10 mm Φ2.15 ± 0.10 mm Φ2.55 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.6 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
75±5 Ohm 63 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 0.9 KV -55°C - +200 °C 31 Kg/Km >60 dB
n a i n
o d le
Ca
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric
Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
106
Attenuation (dB/100 m) 28 39 56 85 98 110 121 128 144
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 8.5 11.9 17.1 25.9 29.9 33.5 36.9 39.0 43.9
www.caledonian-cables.net
Triaxial Cables Tri-RG180 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.13mm) FEP
n o is
7 x 0.10 mm Φ2.60 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.60 ± 0.10 mm Φ4.40 ± 0.10 mm Φ4.80 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
& n
Nom.95±5 Ohm 50 pF/m 70% - Mohm.Km 800.5 Ohm/Km 27.9 Ohm/Km 1.0 KV -55°C - +200 °C 53 Kg/Km >60 dB
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 21 30 43 65 76 85 94 99 111
www.addison-cables.net
Max. Attenuation(dB/100ft) 6.4 9.1 13.1 19.8 23.2 25.9 28.7 30.2 33.8
www.addison-cables.com
107
Triaxial Cabless Tri-RG316 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper covered steel (SCCS) Solid PTFE Silver plated copper( 0.1mm) FEP Silver plated copper(0.1mm) FEP
7 x 0.17 mm Φ1.52 ± 0.10 mm Φ2.05 ± 0.10 mm Φ2.50 ± 0.10 mm Φ3.15 ± 0.10 mm Φ3.60 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 1.0 KV -55°C - +200 °C 31 Kg/Km >60 dB
n a i n
o d le
Ca
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
108
Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4
www.caledonian-cables.net
Triaxial Cables Tri-RG393 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper Solid PTFE Silver plated copper (0.16mm) FEP Silver plated copper (0.2mm) FEP
n o is
7 x 0.80 mm Φ7.25 ± 0.10 mm Φ7.95 ± 0.10 mm Φ9.00 ± 0.10 mm Φ9.90 ± 0.10 mm Φ11.10 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 4.4 KV
-55°C - +200 °C 290 Kg/Km >60 dB
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 7 10 14 22 25 29 32 34 39
www.addison-cables.net
Max. Attenuation(dB/100ft) 2.1 3.0 4.3 6.7 7.6 8.8 9.8 10.4 11.9
www.addison-cables.com
109
Triaxial Cabless Tri-RG400 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper Solid PTFE Silver plated copper(0.13mm) FEP Silver plated copper (0.13mm) FEP
19 x 0.20 mm Φ2.95 ± 0.10 mm Φ3.55 ± 0.10 mm Φ4.30 ± 0.10 mm Φ4.90 ± 0.10 mm Φ5.70 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 1.8 KV -55°C - +200 °C 78 Kg/Km >60 dB
n a i n
o d le
Ca
Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric
Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
110
Attenuation (dB/100 m) 15 22 31 47 55 62 68 72 81
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 4.6 6.7 9.4 14.3 16.8 18.9 20.7 21.9 24.7
www.caledonian-cables.net
Triaxial Cables Tri-RG403 Construction Inner conductor Dielectric Outer conductor (shield 1) Inner sheath Outer conductor (shield 2) Outer sheath
Silver plated copper covered steel(SCCS) Solid PTFE Silver plated copper (0.1mm) FEP Silver plated copper (0.1mm) FEP
n o is
7 x 0.10 mm Φ0.84 ± 0.10 mm Φ1.30 ± 0.10 mm Φ1.90 ± 0.10 mm Φ2.35 ± 0.10 mm Φ2.95 ± 0.10 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operatig Voltage(max) Test Voltage Operating temperature range Cable weight (approx.) Screening effectiveness
& n
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km 0.5 KV
-55°C - +200 °C 21 Kg/Km >60 dB Silvered copper outer conductor 2 Silvered copper outer conductor 1 Solid PTFE dielectric Silvered copper inner conductor FEP inner sheath FEP outer sheath
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 50 67 95 145 165 185 204 215 240
www.addison-cables.net
Max. Attenuation(dB/100ft) 15.2 20.4 29.0 44.2 50.3 56.4 62.2 65.5 73.2
www.addison-cables.com
111
Triaxial Cabless CTX 41 Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH
1.00 mm Φ4.10 ± 0,10 mm 168 x 0.13 mm 95% Φ6.60 ± 0,10 mm h. 20 mm 192 x 0.15 mm 94% Φ8.50 ± 0.10 mm
n a i n
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 7.0 Ohm/Km 7.5 Ohm/Km -25°C - +80 °C 63.3 Kg/Km 111.2 Kg/Km >70 dB
o d le
Ca
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 5.2 7.6 10.8 16.0 18.6 20.8 25.6 28.0
Max. Attenuation(dB/100ft) 1.6 2.3 3.3 4.9 5.7 6.3 7.8 8.5
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
112
>30dB >29dB >28dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Triaxial Cables CTX 44 FLEX
Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Tinned copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
& n
Tinned copper Foam PE Silver plated copper
n o is
d d A
PE Spiral non-migrating tape Plain copper
PVC
7 x 0.35 mm Φ4.40 ± 0.10 mm 168 x 0.12 mm 94% Φ6,60 ± 0.10 mm h. 20 mm 168 x 0.15 mm 93% Φ9.00 ± 0.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 22.5 Ohm/Km 8.5Ohm/Km 6.0 Ohm/Km -30°C - +70 °C 58.7 Kg/Km 115.1 Kg/Km >70 dB
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 5.5 8.1 11.4 17.1 20.0 22.3 27.4 29.9
Max. Attenuation(dB/100ft) 1.7 2.5 3.5 5.25 6.1 6.8 8.4 9.1
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >25dB >23dB
www.addison-cables.com
113
Triaxial Cabless CTX 47 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH
7 x 0.40 mm Φ4.70 ± 0.10 mm 168 x 0.13 mm 94% Φ6.60 ± 0.10 mm h. 20 mm 192 x 0.15 mm 94% Φ8.70 ± 0.10 mm
n a i n
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 20.5 Ohm/Km 7.3Ohm/Km 7.5 Ohm/Km -25°C - +80 °C 64.5 Kg/Km 116.1 Kg/Km >70 dB
o d le
Ca
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 5.2 7.7 10.9 16.3 19.0 21.2 26.1 28.5
Max. Attenuation(dB/100ft) 1.6 2.3 3.3 5.0 5.8 6.5 8.0 8.7
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
114
>27dB >23dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Triaxial Cables CTX 64 Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
& n
Silver plated copper Foam PE Silver plated copper
n o is
d d A
PE Spiral non-migrating tape Plain copper
PVC/LSOH
1.40 mm Φ6.40 ± 0.10 mm 216x 0.13 mm 92% Φ8.60 ± 0.10 mm h. 27 mm 216 x 0.16 mm 92% Φ11.00 ± 0.18 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 11.5 Ohm/Km 6 Ohm/Km 5.8 Ohm/Km -25°C - +80 °C 88.1 Kg/Km 169.25 Kg/Km >70 dB
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 3.7 5.4 8.2 12.1 13.8 15.6 18.8 20.6
Max. Attenuation(dB/100ft) 1.1 1.6 2.5 3.7 4.2 4.8 5.7 6.3
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >28dB >26dB
www.addison-cables.com
115
Triaxial Cabless CTX 65 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
Silver plated copper Foam PE Silver plated copper PE Spiral non-migrating tape Plain copper PVC/LSOH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 15.5 Ohm/Km 6.5 Ohm/Km 5.8 Ohm/Km -25°C - +80 °C 85.2 Kg/Km 165.95 Kg/Km >70 dB
19 x 0,28 mm Φ6,50 ± 0,10 mm 216x 0,13 mm 92% Φ8,70 ± 0,10 mm h. 27 mm 216 x 0,16 mm 92% Φ11.00 ± 0,18 mm
n a i n
o d le
Ca
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 4.4 6.2 9.1 13.3 15.2 17.1 20.6 22.4
Max. Attenuation(dB/100ft) 1.3 1.9 2.8 4.1 4.6 5.2 6.3 6.8
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
116
>28dB >25dB >23dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Triaxial Cables CTX 80 FLEX Plain copper outer conductor 2 Spiral non-migrating tape Silvered copper outer conductor 1 Silvered copper inner conductor Solid PTFE dielectric PE inner sheath PVC outer sheath
Construction
n o is
Inner conductor Dielectric Outer conductor (shield 1) Shield coverage Inner sheath Tape Outer conductor (shield 2) Shield coverage Outer sheath
& n
d d A
Silver plated copper Foam PE Silver plated copper
PE Spiral non-migrating tape Plain copper
PVC/LSOH
7 x 0,65 mm Φ8.00 ± 0,10 mm 216x 0,15 mm 92% Φ10.00 ± 0,10 mm h. 27 mm 216 x 0,18 mm 90% Φ13.00 ± 0,30 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance1 Outer conductor resistance2 Operating temperature range Copper weight Cable weight (approx.) Screening effectiveness
75±5 Ohm 56 pF/m 80% >5000 Mohm.Km 8.0 Ohm/Km 5.0 Ohm/Km 3.5 Ohm/Km -30°C - +70 °C 117.6 Kg/Km 224.35 Kg/Km >70 dB
Attenuation Frequency (MHz) 50 100 200 400 500 600 860 1000
Attenuation (dB/100 m) 3.4 5.1 7.5 10.9 12.4 14.2 17.0 18.8
Max. Attenuation(dB/100ft) 1.0 1.6 2.3 3.3 3.8 4.3 5.2 5.7
Return Loss 30-300 MHz 300-600 MHz 600-900 MHz
www.addison-cables.net
>30dB >28dB >24dB
www.addison-cables.com
117
Mininature Coaxial Cabless
Mininature Coaxial Cables 0.81 mm Mini-Coax 1.13 mm Mini-Coax
n a i n
1.32 mm Mini-Coax
o d le
1.37 mm Mini-Coax 1.48 mm Mini-Coax
Ca
RG174 Mini-Coax RG178 Mini-Coax
RGD178 Mini-Coax RG179 Mini-Coax RG316 Mini-Coax RG316D Mini-Coax 50 VMTX 75 VMTX
118
www.caledonian-cables.co.uk
www.caledonian-cables.net
Mininature Coaxial Cables 0.81 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper PFA Silver plated copper
7 x 0.05 mm Φ0.40 mm 0.05 mm 95% Φ0.81 mm
PFA
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V
Test insulation voltage
Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath
Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000
Attenuation (dB/100 m) 320 400 580 650 740 940
www.addison-cables.net
Max. Attenuation(dB/100ft) 97.5 121.9 176.8 198.1 225.6 286.5
www.addison-cables.com
119
Mininature Coaxial Cabless 1.13 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated annealed copper PFA Silver plated annealed copper PFA
7 x 0.08 mm Φ0.68 mm 0.05 mm 95% Φ1.13 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Test insulation voltage
50±3 Ohm 95.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V
n a i n
o d le
Ca
Silver plated annealed copper outer conductor PFA dielectric
Silvered copper inner conductor PFA sheath
Attenuation Frequency (GHz) 1000 2000 3000 4000 5000 6000
120
Attenuation (dB/100 m) 230 310 390 460 510 580
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 70.1 94.5 118.9 140.2 155.4 176.8
www.caledonian-cables.net
Mininature Coaxial Cables 1.32 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated annealed copper PFA Silver plated annealed copper
7 x 0.08 mm Φ0.66 mm 0.05 mm 91-93% Φ1.32 mm
PFA
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Test insulation voltage
50±3 Ohm 100 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1000V
Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath
Attenuation Frequency (GHz) 1000 2000 3000 4000 5000 6000
Attenuation (dB/100 m) 230 330 400 460 510 560
www.addison-cables.net
Max. Attenuation(dB/100ft) 70.1 100.6 121.9 140.2 155.4 170.7
www.addison-cables.com
121
Mininature Coaxial Cabless 1.37 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated annealed copper PFA Silver plated annealed copper PFA
7 x 0.102 mm Φ0.89 mm 0.05 mm 95% Φ1.37 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Test insulation voltage
50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1KV
n a i n
o d le
Ca
Silver plated annealed copper outer conductor PFA dielectric
Silvered copper inner conductor PFA sheath
Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000
122
Attenuation (dB/100 m) 160 230 290 340 400 430
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 48.8 70.1 88.4 103.6 121.9 131.1
www.caledonian-cables.net
Mininature Coaxial Cables 1.48 mm Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated annealed copper PFA Silver plated annealed copper
7 x 0.102 mm Φ0.86 mm 0.08 mm 95% Φ1.48 mm
PFA
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Test insulation voltage
50±3 Ohm 96 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +180 °C 1KV
Silver plated annealed copper outer conductor PFA dielectric Silvered copper inner conductor PFA sheath
Attenuation Frequency (MHz) 1000 2000 3000 4000 5000 6000
Attenuation (dB/100 m) 155 255 360 410 460 550
www.addison-cables.net
Max. Attenuation(dB/100ft) 47.2 77.7 109.7 125.0 140.2 167.6
www.addison-cables.com
123
Mininature Coaxial Cabless RG174 Mini-Coax Construction Inner conductor Dielectric Outer conductor (shield 1) Outer conductor (shield 2) Sheath
Copper clad steel(CCS) Solid PE Silver plated copper Silver plated copper PVC
7 x 0.16 mm Φ1.52 mm 0.1mm 0.1mm Φ2.80 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Cable weight (approx.)
50±3 Ohm 101 pF/m 66% - Mohm.Km - Ohm/Km - Ohm/Km -40°C - +85 °C 12 kg/km
n a i n
o d le
Ca
PVC sheath Solid PE dielectric Copper covered steel inner conductor Silvered copper outer conductor1 Silvered copper outer conductor2
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
124
Attenuation (dB/100 m) 28 40 58 90 106 119 130 138 155
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 8.5 12.2 17.7 27.4 32.3 36.3 39.6 42.1 47.2
www.caledonian-cables.net
Mininature Coaxial Cables RG178 Mini-Coax Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper PTFE Silver plated copper FEP
n o is
7 x 0.10 mm Φ0.84 mm 0.10 mm 95% Φ1.75 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Cable weight (approx.)
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 7.8 kg/km
FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 46 65 93 140 162 182 200 211 236
www.addison-cables.net
Max. Attenuation(dB/100ft) 14.0 19.8 28.3 42.7 49.4 55.5 61.0 64.3 71.9
www.addison-cables.com
125
Mininature Coaxial Cabless RGD178 Mini-Coax Construction Inner conductor Dielectric Outer conductor (shield 1) Outer conductor (shield 2) Sheath
Silver plated copper Solid PTFE Silver plated copper Silver plated copper FEP
7 x 0.10 mm Φ0.84 mm 0.10 mm 0.10 mm Φ2.25 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Cable weight (approx.)
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 14 kg/km
o d le
Ca
FEP sheath Solid PTFE dielectric Silvered copper covered steel inner conductor Silvered copper outer conductor1
n a i n
Silvered copper outer conductor2
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
126
Attenuation (dB/100 m) 46 65 93 140 162 182 200 211 236
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 14.0 19.8 28.3 42.7 49.4 55.5 61.0 64.3 71.9
www.caledonian-cables.net
Mininature Coaxial Cables RG179 Mini-Coax Construction Inner conductor Dielectric Outer conductor Sheath
Silver plated copper Solid PTFE Silver plated copper FEP
7 x 0.10 mm Φ1.60 mm 0.10 mm Φ2.50 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
d d A
Cable weight (approx.)
75±5 Ohm 63 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km
FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 28 39 56 85 98 110 121 128 144
www.addison-cables.net
Max. Attenuation(dB/100ft) 8.5 11.9 17.1 25.9 29.9 33.5 36.9 39.0 43.9
www.addison-cables.com
127
Mininature Coaxial Cabless RG316 Mini-Coax Construction Inner conductor Dielectric Outer conductor Sheath
Silver plated copper Solid PTFE Silver plated copper FEP
7 x 0.18 mm Φ1.56 mm 0.10 mm Φ2.45 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Cable weight (approx.)
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km
n a i n
o d le
FEP sheath PTFE dielectric Silvered copper inner conductor Silvered copper outer conductor
Ca
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
128
Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4
www.caledonian-cables.net
Mininature Coaxial Cables RG316D Mini-Coax Construction Inner conductor Dielectric Outer conductor 1 Shield coverage Outer conductor 2 Shield coverage Sheath
Silver plated copper Solid PTFE Silver plated copper Silver plated copper
n o is
d d A
FEP
7 x 0.18 mm Φ1.56 mm 0.10 mm 95% 0.10 mm 93% Φ2.94 mm
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Cable weight (approx.)
50±3 Ohm 94 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 15 kg/km
FEP sheath Solid PTFE dielectric Silvered copper covered steel inner conductor Silvered copper outer conductor1 Silvered copper outer conductor2
Attenuation Frequency (MHz) 100 200 400 900 1200 1500 1800 2000 2500
Attenuation (dB/100 m) 27 38 54 82 95 106 117 124 139
www.addison-cables.net
Max. Attenuation(dB/100ft) 8.2 11.6 16.5 25.0 29.0 32.3 35.7 37.8 42.4
www.addison-cables.com
129
Mininature Coaxial Cabless 50VMTX Construction Inner conductor Dielectric Outer conductor Sheath
Silver plated copper clad steel FEP/PTFE Tinned copper braid FEP
0.17 mm Φ0.52 mm Φ0.72 mm Φ1.17 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Cable weight (approx.)
50±5 Ohm 94.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 3kg/km
n a i n
o d le
Ca
FEP sheath Tinned copper outer conductor Silver plated copper clad steel inner conductor FEP/PTFE dielectric
Attenuation Frequency (MHz) 10 100 400 1000 2000 3000
130
Attenuation (dB/100 m) 22 54 115 220 320 450
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 6.7 16.5 35.1 67.1 97.6 137.2
www.caledonian-cables.net
Mininature Coaxial Cables
& n
75VMTX Construction Inner conductor Dielectric Outer conductor Sheath
Silver plated copper clad steel FEP/PTFE Tinned copper braid FEP
0.10 mm Φ0.57 mm Φ0.77 mm Φ1.22 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
d d A
Cable weight (approx.)
75±5 Ohm 72.6 pF/m 70% - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +200 °C 3kg/km
FEP sheath Tinned copper outer conductor Silver plated copper clad steel inner conductor FEP/PTFE dielectric
Attenuation Frequency (MHz) 10 100 400 1000 2000 3000
Attenuation (dB/100 m) 36 70 135 220 320 390
www.addison-cables.net
Max. Attenuation(dB/100ft) 11.0 21.3 41.2 67.1 97.6 118.9
www.addison-cables.com
131
50 Mininature Ohm RF Coaxial Cabless
50Ohm RF Coaxial Cables ALMR100 ALMR195
n a i n
A LMR200 A LMR240
o d le
ALMR300
Ca
ALMR400 ALMR500 ALMR600 3D-FB 5D-FB 7D-FB 8D-FB 10D-FB 12D-FB
132
www.caledonian-cables.co.uk
www.caledonian-cables.net
Mininature 50 Ohm RFCoaxial CoaxialCables Cables ALMR100 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
n o is
0.46 mm Φ1.52 mm Φ1.65 mm Φ2.11 mm Φ2.79 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Min.bending radius
50±3 Ohm 101.1 pF/m 70% >5000 Mohm.Km 266 Ohm/Km 31.2 Ohm/Km -40°C - +85 °C 14 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
Attenuation (dB/100 m) 12.9 16.7 29.4 35.8 51.9 74.9 98.7 109.0 115.5 130.6 143.8 210.3
www.addison-cables.net
Max. Attenuation(dB/100ft) 3.9 5.1 9.0 10.9 15.8 22.8 30.1 33.2 35.2 39.8 43.8 64.1
www.addison-cables.com
133
50 Ohm RF Coaxial Cabless ALMR195 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
Φ3.61 mm Φ9.40 mm Φ9.55 mm Φ10.3 mm Φ12.7 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Min.bending radius
50±3 Ohm 79.7 pF/m 80% >5000 Mohm.Km 24.94 Ohm/Km 16.08 Ohm/Km -40°C - +85 °C 25 mm
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
134
Attenuation (dB/100 m) 6.5 8.4 14.6 17.7 25.5 36.5 47.7 52.5 55.4 62.4 67.5 93.0
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 2.0 2.6 4.5 5.4 7.8 11.1 14.5 16.0 16.9 19.0 20.6 28.3
www.caledonian-cables.net
50 Ohm RF Coaxial Cables ALMR200 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
n o is
Φ1.12 mm Φ2.95 mm Φ3.07 mm Φ3.66 mm Φ4.95 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Min.bending radius
50±3 Ohm 80.3 pF/m 83% >5000 Mohm.Km 17.6 Ohm/Km 16.1 Ohm/Km -40°C - +85 °C 27 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
Attenuation (dB/100 m) 5.8 7.5 13.1 15.9 22.8 32.6 42.4 46.6 49.3 55.4 60.0 86.5
www.addison-cables.net
Max. Attenuation(dB/100ft) 1.8 2.3 4.0 4.8 6.9 9.9 12.9 14.2 15.0 16.9 18.3 26.4
www.addison-cables.com
135
50 Ohm RF Coaxial Cabless ALMR240 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
Φ1.42 mm Φ3.81 mm Φ3.94 mm Φ4.50 mm Φ6.01 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Min.bending radius
50±3 Ohm 79.4 pF/m 84% >5000 Mohm.Km 10.5 Ohm/Km 12.76 Ohm/Km -40°C - +85 °C 30 mm
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
136
Attenuation (dB/100 m) 4.4 5.7 9.9 12.0 17.3 24.8 32.4 35.6 37.7 42.4 46.5 66.8
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 1.3 1.7 3.0 3.7 5.3 7.6 9.9 10.9 11.5 12.9 14.2 20.4
www.caledonian-cables.net
50 Ohm RF Coaxial Cables ALMR300 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
n o is
Φ1.78 mm Φ4.83 mm Φ4.98 mm Φ5.72 mm Φ7.62 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Min.bending radius
50±3 Ohm 78.8 pF/m 85% >5000 Mohm.Km 7.01 Ohm/Km 7.26 Ohm/Km -40°C - +85 °C 38 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
Attenuation (dB/100 m) 3.5 4.5 7.9 9.6 13.8 19.9 26.0 28.7 30.3 34.2 37.5 54.2
www.addison-cables.net
Max. Attenuation(dB/100ft) 1.1 1.4 2.4 2.9 4.2 6.1 7.9 8.7 9.2 10.4 11.4 16.5
www.addison-cables.com
137
50 Ohm RF Coaxial Cabless ALMR400 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
Φ2.74 mm Φ7.24 mm Φ7.39 mm Φ8.13 mm Φ10.29 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Min.bending radius
50±3 Ohm 101.1 pF/m 85% >5000 Mohm.Km 2.92 Ohm/Km 5.41 Ohm/Km -40°C - +85 °C 51mm
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
138
Attenuation (dB/100 m) 2.2 2.9 5.0 6.1 8.9 12.8 16.8 18.6 19.6 22.2 24.8 35.5
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 0.7 0.9 1.5 1.9 2.7 3.9 5.1 5.7 6.0 6.8 7.6 10.8
www.caledonian-cables.net
50 Ohm RF Coaxial Cables ALMR500 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
n o is
Φ3.61 mm Φ9.4 mm Φ9.55 mm Φ10.3 mm Φ12.7 mm
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
& n
Min.bending radius
50±3 Ohm 77.1 pF/m 86% >5000 Mohm.Km 2.69 Ohm/Km 4.2 Ohm/Km -40°C - +85 °C 64 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
Attenuation (dB/100 m) 1.8 2.3 4.0 4.9 7.1 10.3 13.6 15.0 15.9 18.0 19.7 29.1
www.addison-cables.net
Max. Attenuation(dB/100ft) 0.5 0.7 1.2 1.5 2.2 3.1 4.1 4.6 4.8 5.5 6.0 8.9
www.addison-cables.com
139
50 Ohm RF Coaxial Cabless ALMR 600 Construction Inner conductor Dielectric Shield Outer conductor Sheath
Solid copper Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
Φ4.47 mm Φ11.56 mm Φ11.71 mm Φ12.50 mm Φ14.99 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
Min.bending radius
50±3 Ohm 76.8 pF/m 87% >5000 Mohm.Km 1.7 Ohm/Km 3.9 Ohm/Km -40°C - +85 °C 75 mm
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
140
Attenuation (dB/100 m) 1.4 1.8 3.2 3.9 5.6 8.2 10.9 12.1 12.8 14.5 15.7 23.8
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 0.4 0.5 1.0 1.2 1.7 2.5 3.3 3.7 3.9 4.4 4.8 7.3
www.caledonian-cables.net
n
50 Ohm RF Coaxial Cables 3D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid
n o is PVC/PE
Φ1.07 mm Φ3.0±0.02 mm Φ3.2 mm Φ3.6 mm 85% Φ5.4 mm
Electrical & Mechanical Characteristics
dd
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius
50±3 Ohm 82 pF/m 81% >5000 Mohm.Km 19.2(65.2) Ohm/Km 16.3 Ohm/Km -40°C - +85 °C 27 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
Attenuation (dB/100 m) 10.4 13.0 17.5 19.5 21.0 30.0 31.6 37.0 41.5 45.6 46.9 48.2 50.6 54.1
www.addison-cables.net
Attenuation (dB/100 ft) 3.2 4.0 5.3 5.9 6.4 9.1 9.6 11.3 12.6 13.9 14.3 14.7 15.4 16.5
www.addison-cables.com
141
50 Ohm RF Coaxial Cabless 5D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid PVC/PE
Φ1.8 mm Φ5.0±0.02 mm Φ5.2 mm Φ5.7 mm 85% Φ7.5 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius
50±3 Ohm 82 pF/m 82% >5000 Mohm.Km 6.8(10.5) Ohm/Km 14.1 Ohm/Km -40°C - +85 °C 38 mm
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
142
Attenuation (dB/100 m) 6.3 7.8 10.8 12.1 13.0 18.9 20.2 23.7 26.8 29.7 30.6 31.5 33.3 35.8
www.caledonian-cables.co.uk
Attenuation (dB/100 ft) 1.9 2.4 3.3 3.7 4.0 5.8 6.2 7.2 8.2 9.1 9.3 9.6 10.1 10.9
www.caledonian-cables.net
n
50 Ohm RF Coaxial Cables 7D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad steel Foam /Solid PE Bonded aluminium foil Tinned copper braid
n o is PVC/PE
Φ2.6 mm Φ7.3±0.02 mm Φ7.5 mm Φ8.0 mm 85% Φ9.8 mm
Electrical & Mechanical Characteristics
dd
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius
50±3 Ohm 82 pF/m 82% >5000 Mohm.Km 3.3(5.0)) Ohm/Km 9.3 Ohm/Km -40°C - +85 °C 49 mm
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
Attenuation (dB/100 m) 4.3 5.3 7.3 8.3 9.0 13.1 14.2 16.7 19.0 21.2 21.8 22.5 23.8 25.7
www.addison-cables.net
Attenuation (dB/100 ft) 1.3 1.6 2.2 2.5 2.7 4.0 4.3 5.1 5.8 6.5 6.6 6.9 7.3 7.8
www.addison-cables.com
143
50 Ohm RF Coaxial Cabless 8D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(16x9x0.15mm) PVC/PE
Φ2.8 mm Φ7.8±0.02 mm Φ8.0 mm Φ8.6 mm 85% Φ10.6 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
144
50±3 Ohm 82 pF/m 84% >5000 Mohm.Km 2.4(4.4)) Ohm/Km 9.4 Ohm/Km -40°C - +85 °C 52 mm >90 dB >20 dB
Attenuation (dB/100 m) 4.1 5.1 7.1 8.1 8.7 12.9 13.8 16.3 18.6 20.8 21.5 22.1 23.5 25.4
www.caledonian-cables.co.uk
Attenuation (dB/100 ft) 1.2 1.6 2.2 2.5 2.7 3.9 4.2 5.0 5.7 6.3 6.6 6.7 7.2 7.7
www.caledonian-cables.net
n
50 Ohm RF Coaxial Cables 10D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(24x7x0.15mm)
n o is PVC/PE
Φ3.5 mm Φ10.0±0.02 mm Φ10.2 mm Φ10.8 mm 85% Φ13.0 mm
Electrical & Mechanical Characteristics
dd
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss
50±3 Ohm 84 pF/m 80% >5000 Mohm.Km 1.8(2.8)) Ohm/Km 6.4 Ohm/Km -40°C - +85 °C 65 mm >90 dB >20 dB
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
Attenuation (dB/100 m) 3.2 4.1 5.6 6.3 7.0 10.2 11.0 13.1 15.3 16.8 17.4 18.0 18.8 22.5
www.addison-cables.net
Attenuation (dB/100 ft) 1.0 1.2 1.7 1.9 2.1 3.1 3.4 4.0 4.6 5.1 5.3 5.5 5.7 6.3
www.addison-cables.com
145
50 Ohm RF Coaxial Cabless 12D-FB Construction Inner conductor Dielectric Shield Outer conductor Shield coverage Sheath
Bare copper/Copper clad aluminium Foam /Solid PE Bonded aluminium foil Tinned copper braid(24x7x0.15mm) PVC/PE
Φ4.4 mm Φ12.4±0.02 mm Φ12.6 mm Φ13.2 mm 85% Φ15.6 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Min.bending radius Screening effectiveness Return loss
50±3 Ohm 83 pF/m 81% >5000 Mohm.Km 1.2(1.8)) Ohm/Km 4.5 Ohm/Km -40°C - +85 °C 78 mm >90 dB >20 dB
n a i n
o d le
Ca
PVC/PE sheath Foamed/solid PE dielectric Solid copper inner conductor Bonded alunimium foil Tinned copper outer conductor
Attenuation Frequency(MHz) 100 150 280 350 400 800 900 1200 1500 1800 1900 2000 2200 2500
146
Attenuation (dB/100 m) 2.7 3.6 4.6 5.2 6.0 8.5 9.3 10.8 12.3 13.7 14.2 14.6 14.9 16.6
www.caledonian-cables.co.uk
Attenuation (dB/100 ft) 0.8 1.0 1.4 1.6 1.7 2.6 2.8 3.3 3.7 4.2 4.3 4.5 4.5 5.1
www.caledonian-cables.net
50 Ohm RF Coaxial Cables
& n
Semi-rigid Coaxial n Cables
o s di
d A
SR034 SR047/M17 SR086 /M17 SR086-25 SR086-75 SR090-25 SR141 SR141-25 SR141-35 SR141-75 SR250 SR250-75
www.addison-cables.net
www.addison-cables.com
147
Semi-rigid Coaxial Cabless SR034 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel(SCCS) PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, silver plated(SP)
Φ0.20 mm Φ0.66 ± 0.1 mm Φ0.86 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 3.0 mm
n a i n
o d le
Ca
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
148
Max. Attenuation(dB/100m) 112 159 362 520 752
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 34.1 48.5 110.3 158.5 229.2
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR047/M17 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.28 mm Φ0.92 ± 0.1 mm Φ1.20 ± 0.1 mm
n o is
Electrical & mechanical properties
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
50±3 Ohm 95 pF/m - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 4.2 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 79 113 259 374 544
www.addison-cables.net
Max. Attenuation(dB/100ft) 24.1 34.4 78.9 114.0 165.8
www.addison-cables.com
149
Semi-rigid Coaxial Cabless SR086 /M17 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.51 mm Φ1.67 ± 0.1 mm Φ2.20 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm
n a i n
o d le
Ca
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
150
Max. Attenuation(dB/100m) 45 64 151 222 329
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 13.7 19.5 46.0 67.7 100.3
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR086-25 Construction Inner conductor Dielectric
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Outer conductor
Φ0.92 mm Φ1.68 ± 0.1 mm Φ2.20 ± 0.1 mm
n o is
Electrical & mechanical properties
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
Nom.25 Ohm 189.6 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 59 84 197 287 423
www.addison-cables.net
Max. Attenuation(dB/100ft) 18.0 25.6 60.0 87.5 128.9
www.addison-cables.com
151
Semi-rigid Coaxial Cabless SR086-75 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.30 mm Φ1.68 ± 0.1 mm Φ2.20 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
75±5 Ohm 63 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 7.63 mm
n a i n
o d le
Ca
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
152
Max. Attenuation(dB/100m) 48 68 160 234 347
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 14.6 20.7 48.8 71.3 105.8
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR090-25 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ1.02 mm Φ1.85 ± 0.1 mm Φ2.20 ± 0.1 mm
n o is
Electrical & mechanical properties
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
Nom.25 Ohm 190.4 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 8.02 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 53 76 177 258 381
www.addison-cables.net
Max. Attenuation(dB/100ft) 16.2 23.2 53.9 78.6 116.1
www.addison-cables.com
153
Semi-rigid Coaxial Cabless SR141 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.93 mm Φ3.00 ± 0.1 mm Φ3.58 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
50±3 Ohm 95.1 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm
n a i n
o d le
Ca
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
154
Max. Attenuation(dB/100m) 26 38 91 137 209
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 7.9 11.6 27.7 41.8 63.7
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR141-25 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE Seamless bare copper tube
Φ1.63 mm Φ2.98 ± 0.1 mm Φ3.58 ± 0.1 mm
Electrical & mechanical properties
n o is
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
d d A
Nom.25 Ohm 190.4 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 34 48 115 170 257
www.addison-cables.net
Max. Attenuation(dB/100ft) 10.4 14.6 35.1 51.8 78.3
www.addison-cables.com
155
Semi-rigid Coaxial Cabless SR141-35 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE Seamless bare copper tube
Φ1.29 mm Φ2.98 ± 0.1 mm Φ3.68 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
Nom.35 Ohm 136 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm
o d le
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Ca
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
156
Max. Attenuation(dB/100m) 29 41 99 148 225
www.caledonian-cables.co.uk
n a i n
Max. Attenuation(dB/100ft) 8.8 12.5 30.2 45.1 68.6
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR141-75 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.51 mm Φ2.98 ± 0.1 mm Φ3.58 ± 0.1 mm
n o is
Electrical & mechanical properties
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
75±5 Ohm 68.5 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 12.5 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 28 40 97 145 221
www.addison-cables.net
Max. Attenuation(dB/100ft) 8.5 12.2 29.6 44.2 67.4
www.addison-cables.com
157
Semi-rigid Coaxial Cabless SR250 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ1.65 mm Φ5.31 ± 0.1 mm Φ6.35 ± 0.1 mm
Electrical & mechanical properties Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
50±3 Ohm 95.1 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 22.3 mm
n a i n
o d le
Ca
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000
158
Max. Attenuation(dB/100m) 16 23 58 89
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 4.9 7.0 17.7 27.1
www.caledonian-cables.net
Semi-rigid Coaxial Cables SR250-75 Construction Inner conductor Dielectric Outer conductor
Silver plated copper clad steel PTFE type1: Seamless bare copper tube type2: Seamless copper tube, tin plated(TP) type3: Seamless copper tube, Silver plated(SP)
Φ0.94 mm Φ5.44 ± 0.1 mm Φ6.35 ± 0.1 mm
n o is
Electrical & mechanical properties
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Outer conductor integrity temperature Min.bending radius
& n
75±5 Ohm 63.5 pF/m - Mohm.Km - Ohm/Km - Ohm/Km -55°C - +125 °C 175°C 22.3 mm
PTFE dielectric Silvered copper clad steel inner conductor Seamless bare copper tube
Attenuation Frequency(MHz) 500 1000 5000 10000 20000
Max. Attenuation(dB/100m) 4 24 60 93 147
www.addison-cables.net
Max. Attenuation(dB/100ft) 1.2 7.3 18.3 28.3 44.8
www.addison-cables.com
159
Semi-flexible Semi-rigid Coaxial Cabless
Semi-flexible Coaxial Cables
n a i n
SF047
o d le
SF047-FEP
SF086(Flexible RG 405)
Ca
SF086-FEP
SF141(Flexible RG 402) SF141-FEP
SF250(Flexible RG 401) SF250-FEP
160 160
www.caledonian-cables.co.uk
www.caledonian-cables.net
Semi-flexible Semi-rigid Coaxial Coaxial Cables Cables SF047 Construction Inner conductor Dielectric Outer conductor Shield coverage
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.31 mm Φ0.94 ± 0.10 mm Φ1.19 ± 0.10 mm 100%
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
& n
d d A
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 4 mm
Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
Max. Attenuation(dB/100m) 81 116 269 392 577
www.addison-cables.net
Max. Attenuation(dB/100ft) 24.7 35.4 82.0 119.5 175.9
www.addison-cables.com
161 161
Semi-flexible Coaxial Cabless SF047-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.31 mm Φ0.94 ± 0.10 mm Φ1.19 ± 0.10mm 100% Φ1.60 mm
FEP
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 4 mm
n a i n
o d le
Ca
FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
162
Max. Attenuation(dB/100m) 81 116 269 392 577
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 24.7 35.4 82.0 119.5 175.9
www.caledonian-cables.net
Semi-flexible Coaxial Cables SF086 (Flexible RG 405) Construction Inner conductor Dielectric Outer conductor Shield coverage
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.53 mm Φ1.65 ± 0.10 mm Φ2.10 ± 0.10 mm 100%
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
& n
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 6 mm
Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
Max. Attenuation(dB/100m) 46 67 160 239 361
www.addison-cables.net
Max. Attenuation(dB/100ft) 14.0 20.4 48.8 72.8 110.0
www.addison-cables.com
163
Semi-flexible Coaxial Cabless SF086-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.53 mm Φ1.65 ± 0.10 mm Φ2.10 ± 0.10 mm 100% Φ2.50 mm
FEP
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.5KV -65°C - +165 °C 6 mm
n a i n
o d le
Ca
FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
164
Max. Attenuation(dB/100m) 46 67 160 239 361
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 14.0 20.4 48.8 72.8 110.0
www.caledonian-cables.net
Semi-flexible Coaxial Cables SF141 (Flexible RG 402) Construction Inner conductor Dielectric Outer conductor Shield coverage
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.94 mm Φ2.95 ± 0.10 mm Φ3.58 ± 0.10 mm 100%
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
& n
50±3 Ohm 92 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.9KV -65°C - +165 °C 8 mm
Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
Max. Attenuation(dB/100m) 27 39 99 152 239
www.addison-cables.net
Max. Attenuation(dB/100ft) 8.3 11.9 30.2 46.3 72.8
www.addison-cables.com
165
Semi-flexible Coaxial Cabless SF141-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper clad steel Solid PTFE Tinned copper
Φ0.94 mm Φ2.95 ± 0.10 mm Φ3.58 ± 0.10 mm 100% Φ4.10 mm
FEP
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
50±3 Ohm 92 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 1.9KV -65°C - +165 °C 8 mm
n a i n
o d le
Ca
FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
166
Max. Attenuation(dB/100m) 27 39 99 152 239
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 8.3 11.9 30.2 46.3 72.8
www.caledonian-cables.net
Semi-flexible Coaxial Cables SF250 (Flexible RG 401) Construction Inner conductor Dielectric Outer conductor Shield coverage
Silver plated copper Solid PTFE Tinned copper
Φ1.67 mm Φ5.31 ± 0.10 mm Φ6.30 ± 0.10 mm 100%
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
& n
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 3.5KV -65°C - +165 °C 30 mm
Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
Max. Attenuation(dB/100m) 16 24 62 97 145
www.addison-cables.net
Max. Attenuation(dB/100ft) 4.9 7.3 18.9 29.6 44.2
www.addison-cables.com
167
Semi-flexible Coaxial Cabless SF250-FEP Construction Inner conductor Dielectric Outer conductor Shield coverage Sheath
Silver plated copper Solid PTFE Tinned copper
Φ1.67 mm Φ5.31 ± 0.10 mm Φ6.30 ± 0.10 mm 100% Φ6.80 mm
FEP
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Max.operating voltage Operating temperature range Min.bending radius
50±3 Ohm 95 pF/m - Mohm.Km - Ohm/Km - Ohm/Km 3.5KV -65°C - +165 °C 30 mm
n a i n
o d le
Ca
FEP sheath Solid PTFE dielectric Silvered copper clad steel inner conductor Copper-tin composite tube
Attenuation Frequency(GHz) 0.5 1 5 10 20
168
Max. Attenuation(dB/100m) 16 24 62 97 145
www.caledonian-cables.co.uk
Max. Attenuation(dB/100ft) 4.9 7.3 18.9 29.6 44.2
www.caledonian-cables.net
Semi-flexible Coaxial Cables
& n
50Ohm Wideband n o s Coaxial Cables i d
d A
RF42(1-5/8″) RF32(1-1/4″) RF22(7/8″) RF16(5/8″) RF12(1/2″) RF8(3/8″) RF6(1/4″)
www.addison-cables.net
www.addison-cables.com
169
Wideband Coaxial Cabless RF42(1-5/8″) Construction Inner conductor Dielectric Outer conductor Sheath
Corrugated copper tube Foam PE Corrugated copper PE/LSOH
Φ17.4 mm Φ42.8 mm Φ46.5 mm Φ49.5 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.82 Ohm/Km 0.43 Ohm/Km -40°C - +60 °C -55°C - +85°C 11 KV 1340kg/km 1 – 2700 MHz >120dB
o d le
Ca
PE/LSOH sheath Foam PE dielectric Corrugated copper tube inner conductor Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000
Attenuation (dB/100m) 0.20 0.67 0.83 0.98 1.22 1.53 1.63 1.97 2.13 2.28 2.43
Attenuation (dB/100ft) 0.06 0.20 0.25 0.30 0.37 0.47 0.50 0.60 0.65 0.69 0.74
Frequency (MHz) 1500 1700 1800 1900 2000 2100 2200 2300 2500 2700
Attenuation (dB/100m) 3.10 3.35 3.47 3.66 3.71 3.82 3.93 4.05 4.27 4.48
Return Loss 806-960 MHz 1700-2000 MHz
170
n a i n
24.3dB 24.3dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Attenuation (dB/100ft) 0.94 1.02 1.06 1.12 1.13 1.16 1.20 1.23 1.30 1.37
Wideband Coaxial Cables RF32(1-1/4″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper tube Foam PE Corrugated copper PE/LSOH
Φ13.1 mm Φ32.8 mm Φ36.0 mm Φ38.6 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
& n
d d A
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.76 Ohm/Km 0.60 Ohm/Km -40°C - +60 °C -55°C - +85°C 9 KV 940 kg/km 1 – 3300 MHz >120dB
PE/LSOH sheath Foam PE dielectric Copper tube inner conductor Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000
Attenuation (dB/100m) 0.24 0.79 0.98 1.15 1.43 1.78 1.89 2.29 2.47 2.63 2.80
Attenuation (dB/100ft) 0.08 0.26 0.33 0.38 0.48 0.59 0.63 0.76 0.82 0.88 0.93
Frequency (MHz) 1250 1500 1700 1800 2000 2100 2200 2300 2500 2700 3000
Attenuation (dB/100m) 3.19 3.55 3.83 3.96 4.22 4.34 4.47 4.59 4.83 5.06 5.40
Attenuation (dB/100ft) 1.06 1.18 1.28 1.32 1.41 1.45 1.49 1.53 1.61 1.69 1.80
Return Loss 806-960 MHz 1700-2000 MHz
www.addison-cables.net
24.29dB 24.29dB
www.addison-cables.com
171
Wideband Coaxial Cabless RF22(7/8″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper tube Foam PE Corrugated copper tube PE/LSOH
Φ9.0 mm Φ22.3 mm Φ24.9 mm Φ27.5 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
50±3 Ohm 75 pF/m 89% >5000 Mohm.Km 1.05 Ohm/Km 1.18 Ohm/Km -40°C - +60 °C -55°C - +85°C 6 KV 490 kg/km 1 – 5000 MHz >120dB
n a i n
o d le
Ca
PE/LSOH sheath Foam PE dielectric Copper tube inner conductor Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500
Attenuation (dB/100m) 0.37 1.19 1.48 1.72 2.13 2.65 2.81 3.38 3.63 3.87 4.12 5.18
Attenuation (dB/100ft) 0.11 0.36 0.45 0.52 0.65 0.81 0.86 1.03 1.11 1.18 1.26 1.58
Frequency (MHz) 1700 1800 2000 2100 2200 2300 2500 2700 3000 3400 4000 5000
Attenuation (dB/100m) 5.57 5.75 6.11 6.29 6.46 6.63 6.97 7.29 7.76 8.37 9.24 10.59
Return Loss 806-960 MHz 1700-2000 MHz
172
24.3dB 24.3dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Attenuation (dB/100ft) 1.70 1.75 1.86 1.92 1.97 2.02 2.12 2.22 2.37 2.55 2.82 3.23
Wideband Coaxial Cables RF16(5/8″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper clad Aluminium Foam PE Corrugated copper PE/LSOH
Φ7.11 mm Φ18.03 mm Φ19.81 mm Φ22.10 mm
Electrical & Mechanical Characteristics
n o is
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
& n
d d A
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.72 Ohm/Km 1.38 Ohm/Km -40°C - +60 °C -55°C - +85°C 5 KV 401 kg/km 1 – 6100 MHz >120dB
PE/LSOH sheath Foam PE dielectric Copper clad Aluminum inner conductor Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500
Attenuation (dB/100m) 0.48 1.55 1.92 2.24 2.78 3.46 3.66 4.41 4.75 5.06 5.38 6.78
Attenuation (dB/100ft) 0.15 0.47 0.59 0.68 0.85 1.05 1.12 1.34 1.45 1.54 1.64 2.07
Frequency (MHz) 1700 1800 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000
Attenuation (dB/100m) 7.29 7.54 8.02 8.25 8.48 8.70 9.15 9.57 10.20 12.14 13.94 15.63
Attenuation (dB/100ft) 2.22 2.30 2.45 2.52 2.59 2.65 2.79 2.92 3.11 3.70 4.25 4.77
Return Loss 806-960 MHz 1700-2000 MHz
www.addison-cables.net
24.3dB 24.3dB
www.addison-cables.com
173
Wideband Coaxial Cabless RF12(1/2″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper clad Aluminium Foam PE Corrugated copper PE/LSOH
Φ4.83 mm Φ12.95 mm Φ13.97 mm Φ15.88 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
Attenuation (dB/100m) 0.67 2.17 2.67 3.10 3.84 4.75 5.02 6.01 6.46 6.86 7.28 9.09 9.74
Ca
Attenuation (dB/100ft) 0.20 0.66 0.81 0.95 1.17 1.45 1.53 1.83 1.97 2.09 2.22 2.77 2.97
Frequency (MHz) 1800 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800
Attenuation (dB/100m) 10.06 10.67 10.96 11.25 11.54 12.09 12.63 13.41 15.82 18.01 20.06 23.82 25.24
Return Loss 806-960 MHz 1700-2000 MHz
174
n a i n
o d le
PE/LSOH sheath Foam PE dielectric Copper clad Aluminum inner conductor Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 1.90 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 220 kg/km 1 – 8800 MHz >120dB
24.3dB 24.3dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Attenuation (dB/100ft) 3.07 3.25 3.34 3.43 3.52 3.69 3.85 4.09 4.82 5.49 6.12 7.26 7.70
Wideband Coaxial Cables RF8(3/8″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper clad Aluminium Foam PE Corrugated copper PE/LSOH
Φ3.05 mm Φ8.64 mm Φ9.65 mm Φ11.18 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
& n
d d A
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 3.48 Ohm/Km 2.85 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 120 kg/km 1 – 13 GHz >120dB PE/LSOH sheath Copper clad Aluminum inner conductor Foam PE dielectric Corrugated copper tube
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700 1800
Attenuation (dB/100m) 1.06 3.42 4.22 4.90 6.06 7.51 7.95 9.52 10.23 10.87 11.55 14.45 15.49 15.99
Attenuation (dB/100ft) 0.32 1.04 1.29 1.49 1.85 2.29 2.42 2.90 3.12 3.31 3.52 4.41 4.72 4.88
Frequency (MHz) 2000 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800 10000 12000
Attenuation (dB/100m) 16.97 17.44 17.91 18.37 19.26 20.12 21.38 25.26 28.81 32.12 38.24 40.55 43.89 49.21
Attenuation (dB/100ft) 5.17 5.32 5.46 5.60 5.87 6.13 6.52 7.70 8.78 9.79 11.66 12.36 13.38 15.00
Return Loss 806-960 MHz 1700-2000 MHz
www.addison-cables.net
23dB 23dB
www.addison-cables.com
175
Wideband Coaxial Cabless RF6(1/4″) Construction Inner conductor Dielectric Outer conductor Sheath
Copper clad Aluminium Foam PE Corrugated copper PE/LSOH
Φ2.54 mm Φ6.89 mm Φ7.87 mm Φ8.89 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Test voltage Cable weight (approx.) Operating Frequency Band Screening effectiveness
Attenuation Frequency (MHz) 10 100 150 200 300 450 500 700 800 900 1000 1500 1700 1800 2000
Attenuation (dB/100m) 1.25 4.05 4.99 5.80 7.17 8.88 9.39 11.24 12.08 12.84 13.64 17.04 18.27 18.86 20.00
50±3 Ohm 76.8 pF/m 86% >5000 Mohm.Km 5.15 Ohm/Km 4.00 Ohm/Km -40°C - +60 °C -55°C - +85°C 4 KV 90 kg/km 1 – 15.8 GHz >120dB
n a i n
o d le
Ca
PE/LSOH sheath Copper clad Aluminum inner conductor Foam PE dielectric Corrugated copper tube
Attenuation (dB/100ft) 0.38 1.23 1.52 1.77 2.19 2.71 2.86 3.43 3.68 3.91 4.16 5.20 5.57 5.75 6.10
Frequency (MHz) 2100 2200 2300 2500 2700 3000 4000 5000 6000 8000 8800 10000 12000 140000 158000
Attenuation (dB/100m) 20.56 21.10 21.64 22.69 23.70 25.17 29.72 33.87 37.74 44.89 47.58 51.48 57.66 63.55 68.65
Return Loss 806-960 MHz 1700-2000 MHz
176
www.caledonian-cables.co.uk
23dB 23dB
www.caledonian-cables.net
Attenuation (dB/100ft) 6.27 6.43 6.60 6.92 7.23 7.67 9.06 10.33 11.51 13.69 14.51 15.70 17.58 19.38 20.93
Wideband Coaxial Cables
50Ohm Leaky Coaxial Cables n o
& n
s i d
d A
LCX42(1-5/8″)R LCX32(1-1/4″)R LCX22(7/8″)R LCX12(1/2″)R LCX42(1-5/8″) L LCX32(1-1/4″) L LCX22(7/8″) L LCX12(1/2″) L LCX8(3/8″) L
www.addison-cables.net
www.addison-cables.com
177
Leaky Coaxial Cabless LCX42(1-5/8″) R Construction Inner conductor Dielectric Outer conductor Sheath
Helical copper tube Foam PE Overlapping copper foil PE/LSOH
Φ17.4 mm Φ43.0 mm Φ43.8 mm Φ48.3 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.85 Ohm/Km 1.0 Ohm/Km -40°C - +60 °C -55°C - +85°C 1000kg/km/1150kg/km
n a i n
o d le
Ca
PE/LSHF sheath Physical foamed dielectric Helical copper tube inner conductor Overlapping copper foil
Attenuation Frequency(MHz) 75 150 450 800 900
178
Attenuation (dB/100 m) 0.83 0.95 1.90 2.80 3.20
www.caledonian-cables.co.uk
Attenuation (dB/100 ft) 0.25 0.29 0.58 0.85 0.98
www.caledonian-cables.net
Leaky Coaxial Cables LCX32(1-1/4″) R Construction Inner conductor Dielectric Outer conductor Sheath
Smooth copper tube Foam PE Overlapping copper foil PE/LSOH
Φ13.0mm Φ32.8 mm Φ33.6 mm Φ38.2 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
& n
d d A
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.7 Ohm/Km 1.7 Ohm/Km -40°C - +60 °C -55°C - +85°C 840kg/km/970kg/km
PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Overlapping copper foil
Attenuation Frequency(MHz) 75 150 450 800 900
Attenuation (dB/100 m) 1.00 1.35 2.30 4.00 4.35
www.addison-cables.net
Attenuation(dB/100ft) 0.30 0.41 0.70 1.22 1.33
www.addison-cables.com
179
Leaky Coaxial Cabless LCX22(7/8″) R Construction Inner conductor Dielectric Outer conductor Sheath
Smooth copper tube Foam PE Overlapping copper foil PE/LSOH
Φ9.0 mm Φ22.5 mm Φ22.8 mm Φ27.2 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
50±3 Ohm 76 pF/m 89% >5000 Mohm.Km 1.2 Ohm/Km 2.8 Ohm/Km -40°C - +60 °C -55°C - +85°C 420kg/km/480kg/km
n a i n
o d le
Ca
PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Overlapping copper foil
Attenuation Frequency(MHz) 75 150 450 800 900
180
Attenuation (dB/100 m) 1.20 1.80 3.30 5.10 5.50
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 0.37 0.55 1.01 1.55 1.68
www.caledonian-cables.net
Leaky Coaxial Cables LCX12(1/2″) R Construction Inner conductor Dielectric Outer conductor Sheath
Copper-clad Aluminium or copper Foam PE Overlapping copper foil PE/LSOH
Φ4.8 mm Φ12.3 mm Φ13.8 mm Φ15.7 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
& n
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 3.40 Ohm/Km -40°C - +60 °C -55°C - +85°C 190kg/km/230kg/km
PE/LSHF sheath Physical foamed dielectric Copper-clad AL inner conductor Overlapping copper foil
Attenuation Frequency(MHz) 150 450 800 900
Attenuation (dB/100 m) 3.3 5.9 8.4 9.1
www.addison-cables.net
Attenuation(dB/100ft) 1.01 1.80 2.56 2.77
www.addison-cables.com
181
Leaky Coaxial Cabless LCX42(1-5/8″) L Construction Inner conductor Dielectric Outer conductor Sheath
Helical copper tube Foam PE Corrugated copper tube and slot PE/LSOH
Φ17.4 mm Φ42.8 mm Φ46.5 mm Φ49.5 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 0.85 Ohm/Km 0.60 Ohm/Km -40°C - +60 °C -55°C - +85°C 1290kg/km/1430kg/km
n a i n
o d le
Ca
PE/LSHF sheath Physical foamed dielectric Helical copper tube inner conductor Corrugated copper tube and slot
Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400
182
Attenuation (dB/100 m) 0.6 0.8 1.9 2.6 2.7 4.4 5.1 5.5
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 0.18 0.24 0.58 0.79 0.82 1.34 1.55 1.68
www.caledonian-cables.net
Leaky Coaxial Cables LCX32(1-1/4″) L Construction Inner conductor Dielectric Outer conductor Sheath
Smooth copper tube Foam PE Corrugated copper tube and slot PE/LSOH
Φ13.0 mm Φ33.0 mm Φ36.0 mm Φ38.6 mm
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
& n
d d A
50±3 Ohm 76 pF/m 89% >5000 Mohm.Km 0.7 Ohm/Km 0.7 Ohm/Km -40°C - +60 °C -55°C - +85°C 1050kg/km/1150kg/km
PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Corrugated copper tube and slot
Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400
Attenuation (dB/100 m) 0.8 1.1 2.5 3.3 3.5 5.0 5.9 6.5
www.addison-cables.net
Attenuation(dB/100ft) 0.24 0.34 0.76 1.01 1.07 1.52 1.80 1.98
www.addison-cables.com
183
Leaky Coaxial Cabless LCX22(7/8″) L Construction Inner conductor Dielectric Outer conductor Sheath
Smooth copper tube Foam PE Corrugated copper tube and slot PE/LSOH
Φ9.0 mm Φ22.5 mm Φ24.9 mm Φ27.7 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.0 Ohm/Km 1.2 Ohm/Km -40°C - +60 °C -55°C - +85°C 520kg/km/570kg/km
n a i n
o d le
Ca
PE/LSHF sheath Physical foamed dielectric Smooth copper tube inner conductor Corrugated copper tube and slot
Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400
184
Attenuation (dB/100 m) 1.2 1.7 3.1 4.3 4.6 4.9 7.8 8.6
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 0.37 0.52 0.95 1.31 1.40 1.49 2.38 2.62
www.caledonian-cables.net
Leaky Coaxial Cables LCX12(1/2″) L Construction Inner conductor Dielectric Outer conductor Sheath
Coppe clad Aluminium or copper Foam PE Corrugated copper tube and slot PE/LSOH
Φ4.8 mm Φ12.3 mm Φ13.8 mm Φ15.7 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
& n
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 1.48 Ohm/Km 2.10 Ohm/Km -40°C - +60 °C -55°C - +85°C 230kg/km/260kg/km
PE/LSHF sheath Physical foamed dielectric Copper clad AL inner conductor Corrugated copper tube and slot
Attenuation Frequency(MHz) 75 150 450 800 900 1800 2200 2400
Attenuation (dB/100 m) 2.0 2.9 5.3 7.3 7.9 12.0 13.5 14.1
www.addison-cables.net
Attenuation(dB/100ft) 0.61 0.88 1.62 2.23 2.41 3.66 4.12 4.30
www.addison-cables.com
185
Leaky Coaxial Cabless LCX8(3/8″) L Construction Inner conductor Dielectric Outer conductor Sheath
Copper clad Aluminium or copper Foam PE Corrugated copper tube and slot PE/LSOH
Φ3.1 mm Φ8.35 mm Φ9.5 mm Φ11.2 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Cable weight (approx.)
50±3 Ohm 76 pF/m 88% >5000 Mohm.Km 3.1 Ohm/Km 3.1 Ohm/Km -40°C - +60 °C -55°C - +85°C 140kg/km /160kg/km
n a i n
o d le
Ca
PE/LSHF sheath Physical foamed dielectric Copper clad AL inner conductor Corrugated copper tube and slot
Attenuation Frequency(MHz) 75 150 450 800 900 1800
186
Attenuation (dB/100 m) 3.3 4.5 7.5 10.5 11.0 15.8
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 1.01 1.37 2.29 3.20 3.35 4.82
www.caledonian-cables.net
Leaky Coaxial Cables
75Ohm Trunk Coaxial Cables n
& n
d A
o s di
AQR1125 AQR860 AQR715 AQR540 AQR320
www.addison-cables.net
www.addison-cables.com
187
Trunk Coaxial Cabless AQR1125 Construction Inner conductor Dielectric Outer conductor Sheath Messager
Copper-clad Aluminium wire Foam PE Welding solid aluminum tube PE/LSOH
Φ6.68 mm Φ25.58 mm Φ27.46 mm Φ31.12 mm optional
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)
75±5 Ohm 50 pF/m 87% >5000 Mohm.Km 0.76 Ohm/Km 0.61 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 506 kg/km
n a i n
o d le
PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube
Attenuation Frequency(MHz) 5 55 250 300 350 400 450 500 550 600 750 865 1000
Ca
Attenuation (dB/100 m) 0.23 0.76 1.77 1.94 2.13 2.30 2.46 2.62 2.76 2.96 3.31 3.64 3.94
Attenuation(dB/100ft) 0.07 0.23 0.54 0.59 0.65 0.70 0.75 0.80 0.84 0.90 1.01 1.11 1.20
Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz
188
>30dB >30dB >30dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Trunk Coaxial Cables AQR860 Construction Inner conductor Dielectric Outer conductor Sheath Messager
Copper-clad Aluminium wire Foam PE Welding smooth aluminum tube PE/LSOH
Φ5.16 mm Φ20.03 mm Φ21.84 mm Φ24.38 mm optional
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)
& n
75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 1.90 Ohm/Km 1.06 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 316 kg/km
PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube
Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000
Attenuation (dB/100 m) 0.30 1.05 2.30 2.49 2.72 2.89 3.12 3.28 3.48 3.61 4.07 4.36 4.72
Attenuation(dB/100ft) 0.09 0.32 0.70 0.76 0.83 0.88 0.95 1.00 1.06 1.10 1.24 1.33 1.44
Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz
www.addison-cables.net
>30dB >30dB >30dB
www.addison-cables.com
189
Trunk Coaxial Cabless AQR715 Construction Inner conductor Dielectric Outer conductor Sheath Messager
Copper-clad Aluminium wire Foam PE Welding smooth aluminum tube PE/LSOH
Φ4.22 mm Φ17.42 mm Φ18.16 mm Φ19.94 mm optional
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)
75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 1.91 Ohm/Km 1.37 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 215 kg/km
n a i n
o d le
PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube
Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000
Ca
Attenuation (dB/100 m) 0.36 1.18 2.66 2.92 3.18 3.44 3.67 3.90 4.10 4.30 4.89 5.31 5.74
Attenuation(dB/100ft) 0.11 0.36 0.81 0.89 0.97 1.05 1.12 1.19 1.25 1.31 1.49 1.62 1.75
Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz
190
>30dB >30dB >30dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Trunk Coaxial Cables AQR540 Construction Inner conductor Dielectric Outer conductor Sheath Messager
Copper-clad Aluminium Foam PE Welding solid aluminum tube PE/LSOH
Φ3.15 mm Φ13.05 mm Φ13.72 mm Φ15.49 mm optional
n o is
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)
& n
d d A
75±5 Ohm 50 pF/m 88% >5000 Mohm.Km 3.43 Ohm/Km 1.92 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 136 kg/km
PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube
Attenuation Frequency(MHz) 5 50 250 300 350 400 450 500 550 600 750 865 1000
Attenuation (dB/100 m) 0.46 1.54 3.38 3.71 4.03 4.33 4.59 4.89 5.12 5.38 6.07 6.56 7.12
Attenuation(dB/100ft) 0.14 0.47 1.03 1.13 1.23 1.32 1.40 1.49 1.56 1.64 1.85 2.00 2.17
Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz
www.addison-cables.net
>30dB >30dB >30dB
www.addison-cables.com
191
Trunk Coaxial Cabless AQR320 Construction Inner conductor Dielectric Outer conductor Sheath Messager
Copper-clad Aluminium wire Foam PE Welding solid aluminum tube PE/Flame retardant PE
Φ1.80 mm Φ7.47 mm Φ8.13 mm Φ10.03 mm optional
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Installation temperature range Operating temperature range Screening effectiveness Cable weight (approx.)
75±5 Ohm 50 pF/m 87% >5000 Mohm.Km 10.6 Ohm/Km 3.25 Ohm/Km -40°C - +85°C -40°C - +85°C 135 dB 70 kg/km
n a i n
o d le
PE/LSOH sheath Foam dielectric Copper clad AL inner conductor Welding solid aluminum tube
Attenuation Frequency(MHz) 5 55 250 300 350 400 450 500 550 600 750 865 1000
Ca
Attenuation (dB/100 m) 0.79 2.76 6.10 6.69 7.38 7.81 8.27 8.92 9.35 9.78 10.96 11.87 12.76
Attenuation(dB/100ft) 0.24 0.84 1.86 2.04 2.25 2.38 2.52 2.72 2.85 2.98 3.34 3.62 3.89
Return Loss 5-30 MHz 30-470 MHz 470-1000 MHz
192
>30dB >30dB >30dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Trunk Coaxial Cables
& n
BT3002 Coaxial Cables
n o is
d d A
BT3002 Single Core BT3002 8 Core BT3002 16 Core
www.addison-cables.net
www.addison-cables.com
193
BT 3002 Coaxial Cabless BT3002 Single Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper Solid PE Tinned copper braid Tinned copper braid PVC/LSOH
Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ3.55 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)
75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 28.4kg/km
n a i n
o d le
Ca
PVC sheath Tinned copper shield 1 Bare copper inner conductor Solid PE dielectric Tinned copper shield 2
Attenuation Frequency(MHz) 1 4 5 17 70 100 200
194
Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8
www.caledonian-cables.net
BT 3002 Coaxial Cables BT3002 8 Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Inner sheath Outer sheath
Bare copper Solid PE Tinned copper braid
Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ13.45 mm Φ16.0 mm
Tinned copper braid
n o is
d d A
PVC(8 x single core) PVC
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)
75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 335kg/km
BT3002 single core Reininforcement PVC sheath
Attenuation Frequency(MHz) 1 4 5 17 70 100 200
Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0
www.addison-cables.net
Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8
www.addison-cables.com
195
BT 3002 Coaxial Cabless BT3002 16 Core Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Inner sheath Outer sheath
Bare copper Foam/Solid PE Tinned copper braid Tinned copper braid PVC(16 x single core) PVC
Φ0.31 mm Φ1.95 mm Φ2.35 mm 91% Φ2.75 mm 90% Φ16.8 mm Φ21.0 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Max. conductor resistance Rated temperature Cable weight (approx.)
75±5 Ohm 66 pF/m 67% >5000 Mohm.Km 236 Ohm/Km 70°C 500kg/km
n a i n
o d le
Ca
BT3002 single core
PVC sheath
Attenuation Frequency(MHz) 1 4 5 17 70 100 200
196
Attenuation (dB/100 m) 2.3 4.5 4.8 9.2 18.7 22.5 32.0
www.caledonian-cables.co.uk
Attenuation(dB/100ft) 0.7 1.4 1.5 2.8 5.7 6.9 9.8
www.caledonian-cables.net
BT 3002 Coaxial Cables
& n
CT Series Coaxial Cables n o Type s iBritish
d d A
CT 100 CT 125 CT 165
www.addison-cables.net
www.addison-cables.com
197
CT Series Coaxial Cabless CT 100 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper Foam PE Copper Foil
Φ1.00 mm Φ4.60 mm Φ4.75 mm Φ100% 96x0.10 mm 55% Φ6.55 mm
Bare copper braid PVC/LSOH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness
75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 21.4 Ohm/Km - Ohm/Km 70°C 30 V 57 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz)
n a i n
o d le
Ca
PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2
Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150
Attenuation (dB/100 m) 4.6 6.5 9.5 15.0 19.5 21.5 29.0 32.5
Attenuation (dB/100 ft) 1.40 1.98 2.90 4.57 5.95 6.55 8.84 9.91
Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz
198
>23dB >20dB >18dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
n
CT Series Coaxial Cables CT 125 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper Foam PE Copper Foil Bare copper braid
n o is
dd
PVC/LSOH
Φ1.25 mm Φ5.50 mm Φ5.65 mm 100% 96x0.10 mm 60% Φ7.80 mm
Electrical & Mechanical Characteristics
A &
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness
75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 12.8 Ohm/Km - Ohm/Km 70°C 30 V 65 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz) PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2
Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150
Attenuation (dB/100 m) 3.5 5.0 7.5 11.5 15.5 17.0 22.0 26.0
Attenuation (dB/100 ft) 1.07 1.52 2.29 3.51 4.73 5.18 6.71 7.93
Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz
www.addison-cables.net
>23dB >20dB >18dB
www.addison-cables.com
199
CT Series Coaxial Cabless CT 165 Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper Foam PE Copper Foil
Φ1.63 mm Φ7.20 mm Φ7.39 mm 100% 96x0.10 mm 55% Φ10.10 mm
Bare copper braid PVC/LSOH
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Operating voltage Cable weight (approx.) Screening effectiveness
75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 8.45 Ohm/Km - Ohm/Km 70°C 30 V 116 kg/km >75 dB (30-1000MHz) >65 dB (1000-2150MHz)
n a i n
o d le
Ca
PVC/LSOH sheath Bare copper foil shield 1 Bare copper inner conductor Foam PE dielectric Bare copper braid shield 2
Attenuation Frequency(MHz) 50 100 200 460 860 1000 1750 2150
Attenuation (dB/100 m) 3.0 4.0 6.0 9.0 12.5 13.5 19.0 22.0
Attenuation (dB/100 ft) 0.91 1.22 1.83 2.74 3.81 4.12 5.79 6.71
Return Loss 5-470 MHz 470-860 MHz 860-2150 MHz
200
>23dB >20dB >18dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
CT Series Coaxial Cables
& n
TV Coaxial Cables n o Type s iFrance
d d A
19 VATC 17 VATC KX 6 KX 8
www.addison-cables.net
www.addison-cables.com
201
TV Coaxial Cabless 19 VATC Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper/Copper clad steel(CCS) Foam PE Aluminum Foil Aluminum wire braid (Type 1) Aluminum wire braid (Type 2) PVC/FR-PVC
Φ1.02 mm Φ4.60 mm Φ4.75 mm 100% 64x0.12 mm 45% 48x0.12 mm 35% Φ6.80 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Cable weight (approx.) Screening effectiveness
75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 21.4 Ohm/Km - Ohm/Km 70°C - kg/km >70 dB (5-1000MHz)
n a i n
o d le
Ca
PVC or FR-PVC sheath Aluminum foil shield 1 Bare copper inner conductor Foam PE dielectric
Attenuation
Aluminum braid shield 2
Frequency(MHz) 50 100 200 400 800 950 1350 1750 2150 3000
Attenuation (dB/100 m) 4.6 7.1 9.0 13.0 19.0 20.9 25.5 29.6 33.4 40.6
Attenuation (dB/100 ft) 1.40 2.16 2.74 3.96 5.79 6.37 7.77 9.02 10.18 12.38
Return Loss 5-1000 MHz 1000-2000 MHz
202
>22dB >20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
TV Coaxial Cables 17 VATC Construction Inner conductor Dielectric Outer conductor (shield 1) Shield coverage 1 Outer conductor (shield 2) Shield coverage 2 Outer conductor (shield 2) Shield coverage 2 Sheath
Bare copper/Copper clad steel(CCS) Foam PE Aluminum Foil Aluminum wire braid (Type 1)
n o is
d d A
Aluminum wire braid (Type 2) PVC/FR-PVC
Φ1.13 mm Φ4.80 mm Φ4.95 mm 100% 64x0.12 mm 45% 48x0.12 mm 35% Φ6.80 mm
Electrical & Mechanical Characteristics
& n
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Cable weight (approx.) Screening effectiveness
75±5 Ohm 50 pF/m 85% >5000 Mohm.Km 16.8 Ohm/Km - Ohm/Km -25°C - 75°C - kg/km >70 dB (5-1000MHz)
PVC or FR-PVC sheath Aluminum foil shield 1 Bare copper inner conductor Foam PE dielectric
Attenuation
Aluminum braid shield 2
Frequency(MHz) 50 100 200 400 800 950 1350 1750 2150 3000
Attenuation (dB/100 m) 3.7 5.5 8.1 11.7 17.0 18.7 22.8 26.4 29.8 36.2
Attenuation (dB/100 ft) 1.13 1.68 2.47 3.57 5.18 5.70 6.95 8.05 9.09 11.04
Return Loss 5-470 MHz 470-3000 MHz
www.addison-cables.net
>25dB >20dB
www.addison-cables.com
203
TV Coaxial Cabless KX 6 Construction Inner conductor Dielectric Outer conductor shield Shield coverage Sheath
Bare copper Solid PE Bare copper /Copper clad Aluminum(CCA) PVC/FR-PVC
7 x 0.2 mm Φ3.70 mm 96x0.10 mm 80% Φ10.10 mm
Electrical & Mechanical Characteristics Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Rated temperature Cable weight (approx.)
75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 87.5 Ohm/Km 21.0 / 32.5 Ohm/Km 70°C - kg/km
n a i n
o d le
Ca
Bare copper outer conductor Solid PE dielectric
Bare copper inner conductor PVC or FR-PVC sheath
Attenuation
For bare copper braid Frequency Attenuation Attenuation (MHz) (dB/100 m) (dB/100 ft) 1.52 10 5.0 50 8.1 2.47 100 13.0 3.96 200 18.5 5.64 400 22.5 6.86 850 34.5 10.52 950 37.5 11.43 1000 45.0 13.72
Frequency (MHz) 50 100 200 400 850 950 -
For CCA braid Attenuation (dB/100 m) 8.1 13.0 18.5 22.5 34.5 37.5 -
Return Loss 5-1000 MHz
204
>20dB
www.caledonian-cables.co.uk
www.caledonian-cables.net
Attenuation (dB/100 ft) 2.47 3.96 5.64 6.86 10.52 11.43 -
TV Coaxial Cables KX 8 Construction Inner conductor Dielectric Outer conductor shield Shield coverage Sheath
Bare copper Solid PE Bare copper /Copper clad Aluminum(CCA) PVC/FR-PVC
7 x 0.4 mm Φ7.25 mm 192 x 0.10 mm 80% Φ10.20 mm
n o is
Electrical & Mechanical Characteristics
d d A
Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range Screening effectiveness Cable weight (approx.)
& n
75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 22.2 Ohm/Km 15.5 / 16.5 Ohm/Km -25°C - 75°C 65dB(100-3000MHz) - kg/km
Bare copper outer conductor Solid PE dielectric Bare copper inner conductor PVC or FR-PVC sheath
Attenuation For bare copper braid Frequency Attenuation Attenuation (MHz) (dB/100 m) (dB/100 ft) 10 2.9 0.88 50 4.5 1.37 100 6.6 2.01 200 10.9 3.32 400 13.8 4.21 850 23.6 7.20 950 26.8 8.17 1000 27.5 8.38
Frequency (MHz) 10 50 100 200 400 850 950 1000
For CCA braid Attenuation (dB/100 m) 2.9 4.5 6.6 11.9 14.8 24.6 27.8 28.5
Attenuation (dB/100 ft) 0.88 1.37 2.01 3.63 4.51 7.50 8.48 8.69
Return Loss 5-470 MHz 470-3000 MHz
www.addison-cables.net
>25dB >20dB
www.addison-cables.com
205
TV Coaxial Cabless
Reference Notes
n a i n o d e l Ca
Ordering Code
Insulation & Sheath Material Options Amouring Options
Fire Performance Standard
206 206
www.caledonian-cables.co.uk
www.caledonian-cables.net
TV Coaxial Cables Coaxial Cables Ordering Code CCA â&#x20AC;&#x201C; B-CD-EFGH-IJ A - Cable Series. FCX = FIRECOAX B - Standard RG6 = RG 6 equivalent; FRRG6 = Fire Resistant RG 6 equivalent
n o s i d d A
C - Screen Type BC = Bare Copper Braided; TC = Tinned Copper Braid; Aluminium= Aluminium/Polyester Tape; D - Screen Level 60 = 60%; 80 = 80%
& n
E- Bedding/Inner Jacket Y = PVC; 2Y = PE; H = LSOH;
F - Armouring SWA = Steel Wire Armouring; STA = Steel Tape Armouring; SWB = Steel Wire Braiding; DSTA = Double Steel Tape Armouring G - Sheathing Y = PVC; Yu = Flame Retardant PVC; Yv = PVC with reinforced sheath; 2Y = PE; H = LSOH; H - Conductor Construction 7(0.14) = 7/0.14mm I - Fire Propagation Level ( Option ) 1 = IEC 332-1; 3C = IEC 60332 = 3C; 3A = 60332-3A J - Fire Resistant Level ( Option ) 331 = IEC 331; 6386CWZ = BS 6387 CWZ
For Example: CCFCX-RG6-Aluminium100/TC61-H(SWA)H-1/0.95-3A FIRECOAX Series, RG6, 100% Aluminium/Polyester tape + 61% Tinned Copper Braid, LSOH Bedding, Steel Wire Armoured, LSOH Sheathed, 1/0.95mm, fire propagation to IEC 332-3A
www.addison-cables.net
www.addison-cables.com
207 207
Coaxial Cabless Insulation & Sheath Material Options Polyvinyl Chloride(PVC) PVC is the most widely used material throughout the cable industry because of its good mechanical and electrical properties, combined with cheap cost. The three most common materials used are PVC(-20°C to 80℃), PVC105℃(-20℃ to 105℃), PVCAF which is flame retardant (oxygen index>32% and halogen content<18 %.)
Polyethylene (PE) PE has excellent insulation characteristics and is used for data and RF transmission. It is very resistant to water penetration and thus used as sheath for outdoor/underground cables. It has three major types, ie. Low, (LDPE) medium (MDPE) and high (HDPE). Generally speaking, the higher the density, the better the mechanical performance. Cellular polyethylene has even lower Nominal capacitance than solid PE and is used for low loss data cable.
n a ni
Fluoropolymer (PTFE/FEP/PFA/ETFE)
o d le
The three most common materials used are Polytetrafluorethylene (PTFE) (-80℃ to 260℃),
Flurethylene-propylene (FEP)(-80℃ to 260℃), Polyfluoroalkoxy (PFA)(-80°C to 260°C) and Eth
Ca
ylenetetraflurorethylene(ETFE)(-80°C to 155°C),These materials are usually used in aerospace industry where wide temperature range is required.
Low Smoke Halogen Free(LSOH)
It is a flame retardant compound designed to reduce both the spread of fire and the volume of toxic gas and smoke during a fire. It is usually used in Mass Transit Railway, banking and high rise building.
208
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables Armouring Options Metallic armour are used when cables have to be installed direct buried, or if mechanical protection is required.Following points must be considered: ■■ Required tensile load ■■ Expected pressure on cable during service ■■ Protection against rodent ■■ Protection against accidental damage ■■ Minimum required bending radius
n o is
d d A SWA
& n
GSWB
SWA: single layer of galvanized steel wires, with diameters according to relevant standards, coverage min. 90%. This armour assures a very good mechanical protection and tensile strength. An additional counterspiral tape increases solidity, if required. GSWB: galvanized steel wire braid, diameter of wire: 0.20 – 0.25 – 0.30 – 0.40 mm, with coverage of > 80%. It assures a good mechanical resistance, allowing a lower bending radius compared to other armour. It is preferable when there is movement or vibration. For special application is possible to use stainless steel, tinned copper or special alloy wires.
GSTA
GSFA
GSTA: galvanized steel tape armour, composed by two tapes with overlapped edge; thickness of each tape: 0.20 – 0.30 – 0.40 mm, according to cable diameter. It grants a coverage > 100%. Very good crush resistance, but fair tensile strength. Brass tape of minimum thickness 0.075 mm can be used for special applications. GSFA: galvanized steel flat armour. It is composed by flat wire of thickness 0.6 mm or 0.8 mm, it is similar to SWA, but with higher mechanical protection.
www.addison-cables.net
www.addison-cables.com
209
Coaxial Cabless Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables.
◎ Flame Retardant
Fire retardant cables are designed for use in fire situations where the spread of flames along a cable route needs to be retarded. Due to relative low cost, fire retardant cables are widely used as fire survival cables. No matter the cables are installed in single wire or in bundles, during a fire, the flame spread will be retarded and the fire will be confined to a small area, thus reducing the fire hazard due to fire propagation.
◎ Low Smoke & Halogen Free & Fire retardant ( LSZH)
LSZH cables are not only characterized by the fire retardant performance but also by the halogen free properties, thus offering low corrosivity and toxicity. During a fire, the LSZH cables will emit less smoke and acid gases which may damage the human being and expensive equipment. Compared with normal PVC cables, LSZH cables outperform by their fire retardancy, low corrosivity and low smoke emission properties, however, normal PVC cables have better mechanical and electrical properties.
n a ni
o d le
◎ Low Smoke Fume (LSF)
The low halogen content and low corrosivity of low smoke fume cables lies somewhat in between their of fire retardant cables and LSZH cables. LSF cables also contain halogen but the content is much less than that of PVC cables. LSF cables are designed to reduce the spread of fire, toxic gases and smoke during fire. The LSF cables are usually manufactured from flame retardant PVC blended with HCL additive and smoke absorbent. These materials help improve the fire performance of the LSF cables.
◎ Fire Resistant (FR)
Ca
Fire resistant cables are designed to maintain circuit integrity of those vital emergency services during the fire. The individual conductors are wrapped with a layer of fire resisting mica/glass tape which prevents phase to phase and phase to earth contact even after the insulation has been burnt away. The fire resistant cables exhibit same performance even under fire with water spray or mechanical shock situation.
◎ Fire Performance Class
The main concerns for the cables in their fire survival properties are their flame spread, smoke characterization and gas toxicity. In American fire standard, the concern lies more on the first two and it differs from the European standard which concerns all these aspects. In USA, it is believed that the fire hazard is mainly due to CO toxic gas emitted and the heat release during the conversion of CO to CO2 during the fire. Therefore, to control the heat release is the most important concern for reducing the fire hazard. However, in European countries, halogen content, the corrosivity of the gases, the smoke density and the toxicity of the gas are equally important factors affecting the safety and survival of human during a fire.
210
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables IEC Standard for Flame Retardancy The European Electrical Committee categorizes the fire performance of the cables into three classes, namely IEC 60332-1, IEC 60332-2, IEC 60332-3. IEC 60332-1 and IEC 60332-2 are used to assess the flame propagation characteristics of a single wire. IEC 60332-3 is used to assess the flame propagation characteristics of bundled cables. Comparatively speaking, IEC 60332-3 for bundled cables is more demanding than IEC 60332-1 for single wires.
â&#x2014;&#x17D; IEC 60332-1/BS 4066-1 (Flame Test On Single Vertical Insulated Wires/Cables)
n o is
This test details a method of test for the assessment of the flame propagation characteristics of a single wire or cable. In this test, a 60cm cable sample is fixed vertically inside a metallic box and a 175mm long flame is applied at 45mm from a gas burner placed at 450mm from the top at the upper portion. The specimen is deemed to have passed this test, if after burning has ceased, the charred or affected position does not reach within 50mm of the lower edge of the top clamp which is equivalent to 425mm above the point of flame application. The test method is not suitable for the testing of some small wires due to the melting of the conductors during the time of application of the flame.
& n
d d A
â&#x2014;&#x17D; IEC 60332-3/BS 4066-3 (Flame Test On Bunched Wires/Cables) IEC60332-3C describes a method of type approval testing to define the ability of bunched cables to resist fire propagation. In this test, a cable specimen, consisting of number of 3.5m length of cables are fixed to a vertical ladder tray where they are applied with a flame from a gas burner for a specified times under controlled air flow. Four categories (A, B, C & D) are defined and distinguished by test duration and the volume of non metallic material of the sample under test. The cable specimen is deemed to have met the requirements of the standard if, after burning has ceased, the extent of charred or affected portion does not reach a height exceeding 2.5m above the bottom edge of the burner.
www.addison-cables.net
www.addison-cables.com
211
Coaxial Cabless UL Standard for Fire Retardancy ◎ CMP (Plenum Flame Test/ Steiner Tunnel Test)
Plenum rated cables meet the NFPA -262 standard (formerly known as UL910) which provides the most stringent requirement of all the tests. Cable samples on a horizontal tray in a tunnel type of chamber are burned at 87.9KW (300,000 BTU/Hr) for 20 minutes. To qualify for a plenum rating the cable specimen must have the flame spread of less than 5 feet or 1.5 meters with a smoke density during the test of (a) 0.5 peak and 0.15 maximum average. The CMP cables are usually installed in air ventilation ducts and air returns widely used in Canada and USA. The fire retardant properties of CMP cables are much better than that of normal LSZH cables complying with IEC 60332-1 and IEC 60332-3.
◎ CMR (Riser Flame Test)
Riser rated cables meets UL1666. Cable samples on a vertical shaft are burned at 154.5KW (527,500 BTU/Hr) for 30 minutes. To qualify for a riser rating, cable specimen must have the flame spread of less than 12 feet beyond the ignition point. This test does not look at the smoke density or toxicity. Riser rated cables are suitable for vertical shafts not defined as an environmental air plenum.
◎ CM (Vertical Tray Flame Test)
n a ni
o d le
General purpose cables meet UL 1581. Cable samples on a 8 feet vertical tray are burned at 20KW (70,000 BTU/Hr) for 20 minutes. The cable specimen is deemed to pass the test if the flame spread will not extend to the upper portion and extinguish by itself. UL 1581 is similar to IEC 60332-3C except for that the number of testing samples is different. This test does not look at the smoke density or toxicity. The CMG cables are usually used in runs penetrating single floor. These cables cannot be installed in vertical pathways.
Ca
◎ CMG (Vertical Tray Flame Test)
These general purpose cable also meet UL1581. CM and CMG are similar and both are recognized in Canada and USA. This test does not look at the smoke density or toxicity. The CMX cables are usually used in runs penetrating single floor. The cables cannot be installed in vertical pathways.
◎ CMX (Vertical Wire Flame Test) The restricted cables meet UL1581 Limited-use. The test consists of 25 feet long ventilated tunnel. The cable specimen is placed on a ladder inside the tunnel and the flame of 30,000 BTU/ Hr is applied to the cable 15 seconds on and 15 seconds off five times for a total exposure to the flame of 1 minute and 15 seconds. To qualify for this test, after the test flame is removed the cable specimen can flame for not more than 60 seconds and the charred portion will not exceed by 25%. UL 1581 VW-1 is similar to IEC 60332-1 except for the difference in the time for flame applied. This test does not look at the smoke density or toxicity. The CMG cables are suitable for use in dwellings and for use in raceway. These cables cannot be installed in bundles and must be protected in metal conduit. This type of cable is chosen as the minimum requirement for commercial installations.
212
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables Standard for Fire Resistance Fire resistant cables are designed for maintaining circuit integrity during a fire. The IEC and the BS adopted two different standards, namely the IEC 60331 and BS 6387.Comparatively speaking, the fire performance requirement for BS 6387 is more demanding.
◎ IEC60331 Fire Resistance Test A cable sample is placed over a gas burner and connected to an electrical supply at its rated voltage. Fire is applied for a period of 3 hours. The temperature on the cable is between 750°C and 800°C. After 3 hours, the fire and the power is switched off. 12 hours later, the cable sample is reenergized and must maintain its circuit integrity.
n o is
d d A
◎ BS6387 Fire Resistance Test
& n
BS6387 specifies the performance requirements for cables required to maintain circuit integrity under fire conditions. It details the following methods to categorize the cables according to cable withstand capacities. Resistance to fire alone - the cables is tested by gas burner flame while passing a current at its rate voltage. Four survival categories are defined Cat A (3 hours at 650°C) ,Cat B (3 hours at 750°C), Cat C (3 hours at 950°C), and Cat S (20 minutes at 950°C). Resistance to fire with water spray - a new sample of cable is exposed to flame at 650°C for 15 minutes while passing a current at its rated voltage and then the spray is turned on to give exposure to both fire and water for a further 15 minutes. A single survival category W is defined if the cables surpassed the testing requirement. Resistance to fire with mechanical shock - the final requirement is mechanical shock damage. A fresh sample is mounted on a backing panel in an S bend and is exposed to flames while the backing panel is stuck with a steel bar with the same diameter as the cables under test every 30 seconds for 15 minutes. The cables will be tested under the following temperatures: X ( 650°C/15min ), Y( 750°C/15min ) and Z ( 950°C/15min ). The highest standard for BS 6387 is CWZ.
www.addison-cables.net
www.addison-cables.com
213
Coaxial Cabless Standard for Halogen & Smoke Emission, Corrosivity & Toxicity ◎ IEC 60754-1/BS6425-1 (Emission Of Halogens) This specifies a test for determination of the amount of halogen acid gas other than the hydrofluoric acid evolved during combustion of compound based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. Halogen includes Florine, Chlorine, Bromine, Iodine and Astatine. All these elements are toxic by their nature. In this test, when the burner is heated to 800℃,1g sample is placed inside and the HCL is absorbed into water inside the chamber fed with air flow. The water is then tested with its acidity. If the hydrochloric acid yield is less than 5 mg/g, the cable specimen is categorized as LSZH. If the hydrochloric acid yield lies between 5mg/g to 15mg/g, the cable specimen is categorized as LSF. IEC60754-1 cannot be used for measuring the exact HCL yield if the yield is less than 5mg/g. This test cannot determine if the cable is 100% halogen free or not. To determine if the cable specimen is 100% halogen free or not, IEC60754-2 has to be employed.
n a ni
◎ IEC 60754-2 (Corrosivity)
o d le
This test specifies a method for the determination of degree of acidity of gases evolved during combustion of the cable specimen by measuring its pH and conductivity. The specimen is deemed to pass this test if the pH value is not less than 4.3 when related to 1 litre of water and conductivity is less than 10us/min. When the HCL yield lies between 2mg/g and 5mg/g, a cable specimen can pass IEC 60754-1 but its pH value will likely be less than 4.3 and therefore cannot pass the IEC 60754-2 test.
Ca
◎ IEC 61034-1/ASTM E662 (Emission of Smoke) This specifies a test for determination of smoke density. The 3 metre cube test measures the generation of smoke from electric cables during fire. A light beam emitted from a window is projected across the enclosure to a photo cell connected to a recorder at the opposite window. The recorder is adjusted to register from 0% for complete obscuration to 100% luminous transmissions. A 1 metre cable sample is placed in the centre of the enclosure and is applied with a fire. The minimum light transmission is recorded. The result is expressed as percentage of light transmitted. The specimen is deemed to pass this test (IEC61034-1 & 2) if the value is greater than 60% .The higher the light transmittance, the less smoke emitted during a fire.
214
www.caledonian-cables.co.uk
www.caledonian-cables.net
Coaxial Cables ◎ ISO4589-2/BS2863 (Oxygen Index LOI)
This is a test for assessing the oxygen index of the material in accordance with the test method specified in ASTM D2863-95(Measuring the minimum oxygen concentration to support candlelike combustion of plastics). At room temperature when the oxygen content in the air exceeds the oxygen index, the material will burn by itself automatically. The higher the oxygen index, the more retardant the cable will be. For example, if the oxygen index of a material is 21%, it means that the material will burn by itself even at room temperature because at room temperature the normal oxygen content is 21%. In general, the oxygen index of a LSZH cables ranges from 33% to 42%.
◎ ISO4589-3/BS2782.1 (Temperature Index TI)
n o is
This is a test for assessing the performance of a material when it is tested in accordance with BS2782 Part 1 Method 143A and 143B. The oxygen index of a material will drop when the temperature rises. When the temperature rises and the oxygen index drops to 21%, the material will burn automatically. This temperature is defined as temperature index. For example, the temperature index of coal is 50%. When the temperature climbs to 150℃, its oxygen index drop to 21% and the coal will burn by itself automatically. The temperature index of the coal will then be defined as 150℃. In general, the temperature index of LSZH cables ranges from 250℃ to 300℃.
& n
d d A
◎ ES713 (Toxicity Index)
This is a test defined by Naval Engineering Standard which is a directed at the analysis of a specified set of gaseous species which are commonly present in the combustion products of materials used in military application and which may cause lethality at the time of a fire. In this test a 1g cable specimen is completely burnt inside a sealed chambers of volume 0.7-1m3 using a burner fed with air and gas to give a non-luminous flame. The resulting chamber atmosphere is quantitatively analysed for a specified set of gases. For each gas, the measured concentration (Ci) is scaled up for 100g and the concentration is recalculated as though the combustion products is diffused into a volume of exactly 1m3. The resulting concentration (C8) is expressed as the ratio of critical factor (Cf) which is equal to the concentration of this gas considered fatal to human for 30 minutes exposure. The ratio C8/Cf are summed for all gases detected to give the toxicity index .The higher the toxicity index, the more toxic the cable materials are. In general, the toxicity index of LSZH materials are less than 5. LSZH cable will also emit toxic CO and if the cable materials contains P, N and S, the toxic gases generated will even be greater. Thus LSZH cables cannot be categorized as toxic free. CM, CMR and CMP cables in general contains halogen elements which are essential for passing the strict fire retardancy testing. For example, CMP cables are made from FEP which contains Flourine and are much toxic than normal LSZH cables.
www.addison-cables.net
www.addison-cables.com
215
Coaxial Cabless
o d le
n a ni
Ca
216
www.caledonian-cables.co.uk
www.caledonian-cables.net
Caledonian Coaxial Cables Cables Ltd Merchant Ind. Centre Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ England United Kingdom Tel: 44- 207- 4195087 Fax: 44- 207- 8319489 Email: sales@caledonian-cables.com sales@caledonian-cables.co.uk uk@addison-tech.com
& n
n o is
d d A
Addison
www.addison-cables.net
www.addison-cables.com
217