Industrial Cables(Australian Standard Low Voltage)

Page 1

Caledonian Industrial Cables Plain annealed copper conductor PVC insulation

PVC sheath Australian Standard

CaledonianCables CablesLtd Ltd Caledonian Industrial Cables Cables Industrial Australian Standard Low Voltage

Addison

Addison 1


Addison Industrial Cables Australian Standard

Company Profile

Caledonian. established in 1978.offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. . Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Caledonian Cables offers a comprehensive st°Ck of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison. produces a wide range of cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our E commerce technologies. to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design. manufacturing. and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.

2


Caledonian Industrial Cables Our Certificate Australian Standard

3


Addison Industrial Cables Australian Standard

Table of Content V75 PVC Light Duty Flexible Cord, 250/250V.................................................7 V90 PVC Light Duty Flexible Cord, 250/250V.................................................9 V75 PVC Ordinary Duty Flexible Cord, 250/400V........................................ 11 V90 PVC Ordinary Duty Flexible Cord, 250/400V........................................13 V75 PVC Heavy Duty Flexible Cord, 0.6/1kV................................................15 V90 PVC Heavy Duty Flexible Cord, 0.6/1kV................................................18 Single Core Flexible Power Cable, 0.6/1kV .................................................21 Single Core Double Insulated Flexible Power and Welding Cable, 0.6/1kV.................................................23 Flame Retardant Zero Halogen Crosslinked Thermoset Single Core X-HF-110 Flexible Power Cable, 0.6/1kV..................................25 Zero Halogen Flame Retardant 1100C Double Insulated Cable, 0.6/1kV...................................................................27 Single Core V90HT, 0.6/1kV ..........................................................................29 Single core XLPE Insulated, PVC Sheathed Unarmoured Cables, 0.6/1kV.........................................................................31 XLPE Insulated, PVC Sheathed Unarmored Multicore control Cables, 0.6/1kV.............................................34 XLPE Insulated, PVC Sheathed 2 core+E Unarmored Cables, 0.6/1kV...........................................................36 XLPE Insulated, PVC Sheathed 3 core+E Unarmored Cables, 0.6/1kV...........................................................38

4


Caledonian Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 4 core+E Unarmored Cables, 0.6/1kV...........................................................40 XLPE Insulated, PVC Sheathed 2 core+E Armored Cables, 0.6/1kV...............................................................42 XLPE Insulated, PVC Sheathed 3 core+E Armored Cables, 0.6/1kV...............................................................44 XLPE Insulated, PVC Sheathed 4 core+E Armored Cables, 0.6/1kV...............................................................46 PVC Insulated, Single Core Cable, 450/750V...............................................48 PVC Insulated, Round Cables, 450/750V......................................................50 PVC Insulated, PVC Sheathed 2 core+E Round Cables, 450/750V................................................................54 PVC Insulated, PVC Sheathed 3 core+E Round Cables, 450/750V................................................................56 PVC Insulated, PVC Sheathed 4 core+E Round Cables, 450/750V................................................................58 PVC Insulated, 2 Cores Flat Cables, 450/750V............................................60 PVC Insulated, 3 Cores Flat Cables, 450/750V............................................62 PVC Insulated, 4 Cores Flat Cables, 450/750V............................................64 PVC Insulated, 2 Core + E Flat Cables, 450/750V........................................66 PVC Insulated, 3 Core + E Flat Cables, 450/750V........................................68 PVC Insulated, PVC Sheathed 2 core+E Unarmored Cables, 0.6/1kV...........................................................70

5


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 3 core+E Unarmored Cables, 0.6/1kV...........................................................72 PVC Insulated, PVC Sheathed 4 core+E Unarmored Cables, 0.6/1kV...........................................................74 PVC Insulated, PVC Sheathed 2 core+E Armored Cables, 0.6/1kV...............................................................76 PVC Insulated, PVC Sheathed 3 core+E Armored Cables, 0.6/1kV...............................................................78 PVC Insulated, PVC Sheathed 4 core+E Armored Cables, 0.6/1kV...............................................................80 PVC Insulated, PVC Sheathed Multi-core+E Control Cables, 0.6/1kV...........................................................82 PVC Insulated, PVC Sheathed Multicore+E Armored Control Cables, 0.6/1kV............................................84 Flexible VSD/EMC Cables, 0.6/1kV...................................................................86 VSD/EMC Cables (Copper Tape Screened), 0.6/1kV.........................................90

6


Caledonian Industrial Cables Australian Standard V75 PVC Light Duty Flexible Cord, 250/250V Application These cables are suitable for installing in dry applications only. They are use in radios, shavers, desk lamps and small portable equipment or use in office machines, hair dryers etc.and for appliances requiring an earth connection. Also suitable for use with double insulated appliances where the cord is not subject to mechanical stress.

Standard AS/NZS 3191, AS/NZS 1125

Cable Construction Annealed copper conductor PVC insulation

Conductor: Annealed copper conductor to AS/NZS 1125 Maximum operating temperature: 75째C

Insulation: V-75 PVC Colours: 2C Brown, Light Blue 3C Brown, Light Blue, Green/Yellow

Sheath: 4V-75 PVC Colours: Grey, White, Black, Orange

Technical Characteristics Conductor Size mm2

0.5 0.75 1.0 1.5 2.5 4.0

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 째C

39.0 26.0 19.5 13.3 7.98 4.95

Max. AC Resistance Ohm/km @ 90 째C

47.4 31.6 23.7 16.2 9.70 6.02

Single Phase Voltage Drop MV/A.m

94.7 63.2 47.5 32.3 19.4 12.0

7


Addison Industrial Cables Australian Standard Annealed copper conductor PVC insulation PVC outer jacket

Cable Parameter Conductor Size

No.of cores

mm2

0.5 0.5 0.75 0.75 0.5 0.75

8

2 3 2 3 2 2

Nominal Insulation Thickness mm

0.5 0.5 0.5 0.5

Nominal Sheath Thickness mm

Round

Nominal O.D.

Approx.cable weight

mm

kg/100m

5.2 5.5 5.6 5.9

3.7 4.2 4.5 5.4

5.2Ă—2.6 5.6Ă—2.8

2.2 2.7

0.6 0.6 0.6 0.6

Parallel Webbed, Flat, Unsheathed 0.8 0.8

-


Caledonian Industrial Cables Australian Standard V90 PVC Light Duty Flexible Cord, 250/250V Application These cables are suitable for installing in dry applications only. They are use in radios, shavers, desk lamps and small portable equipment or use in office machines, hair dryers etc.and for appliances requiring an earth connection. Also suitable for use with double insulated appliances where the cord is not subject to mechanical stress.

Standard AS/NZS 3191, AS/NZS 1125

Cable Construction Annealed copper conductor PVC insulation

Conductor: Annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 90째C

Insulation: V-90 PVC Colours: 2C Brown, Light Blue 3C Brown, Light Blue, Green/Yellow

Sheath: 5V-90 PVC Colours: Grey, White, Black, Orange

Technical Characteristics Conductor Size mm2

0.5 0.75 1 1.5 2.5 4

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 째C

39 26 19.5 13.3 7.98 4.95

Max. AC Resistance Ohm/km @ 90 째C

49.7 33.2 24.9 17 10.2 6.31

Single Phase Voltage Drop MV/A.m

99.4 66.3 49.8 34 20.3 12.6

9


Addison Industrial Cables Australian Standard PVC outer jacket Annealed copper conductor PVC insulation

Annealed copper conductor PVC insulation PVC outer jacket

Cable Parameter Conductor Size

No.of cores

mm2

mm

0.5 0.75

2 2

0.5 0.5

0.5 0.5 0.75 0.75

2 3 2 3

0.5 0.5 0.5 0.5

0.5 0.75 1.0 1.5 2.5 4

10

Nominal Insulation Thickness

2 2 2 2 2 2

Nominal Sheath Thickness

Nominal O.D.

Approx.cable weight

mm

mm

kg/100m

0.6 0.6

5.2×3.3 5.6×3.5

2.8 3.4

0.6 0.6 0.6 0.6

5.2 5.5 5.6 5.9

3.7 4.2 4.5 5.4

5.2×2.6 5.6×2.8 6.0×3.0 6.6×3.3 7.9×3.9 9.3×4.7

2.2 2.7 3.3 4.5 6.6 11.0

Flat

Round

Parallel Webbed, Flat, Unsheathed 0.8 0.8 0.8 0.8 0.9 1.0

-


Caledonian Industrial Cables Australian Standard V75 PVC Ordinary Duty Flexible Cord, 250/400V Application These cables are suitable for installation in dry applications only, in conduit or enclosures, such as switchboards, control panels, appliances and electrical equipment. such as radios, desk lamps and office machines, etc. Also they are used for extension leads in sizes 1 mm2 and above. Multicore cords containing an E core are suitable for a number of applications in dry and damp conditions, such as domestic appliances (washing machines, dishwashers). Leads for industrial and office equipment requiring a three-phase supply and an earth connection.

Standard PVC outer jacket Annealed copper conductor PVC insulation

AS/NZS 3191 AS/NZS 1125

Cable Construction Annealed copper conductor PVC insulation PVC outer jacket

Conductor: Annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 75째C

Insulation: V-75 PVC Colours: 1C - Red, White, Light Blue, Black 2C - Brown, Light Blue 3C - Brown, Light Blue, Green/Yellow 4C - Brown, Light Blue, White, Green/Yellow 5C - Brown, Light Blue, Orange, White, Green/Yellow

Sheath: 4V-75 PVC Colours: Grey, White, Black, Orange

11


Addison Industrial Cables Australian Standard Technical Characteristics Conductor Size mm2

0.5 0.75 1.0 1.5 2.5 4.0

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 °C

39.0 26.0 19.5 13.3 7.98 4.95

Max. AC Resistance Ohm/km @ 90 °C

47.4 31.6 23.7 16.2 9.70 6.02

Single Phase Voltage Drop MV/A.m

94.7 63.2 47.5 32.3 19.4 12.0

Cable Parameter Conductor Size

No.of cores

mm2

12

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

0.5 0.75 1.0 1.5 2.5 4

1 1 1 1 1 1

0.6 0.6 0.6 0.7 0.8 0.8

0.5 0.75

2 2

0.6 0.6

0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4

2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5

0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8

Round

Flat Round

Nominal O.D.

Approx.cable weight

mm

kg/100m

-

2.2 2.4 2.5 3.0 3.7 4.2

0.9 1.2 1.5 2.1 3.4 4.8

0.8 0.8

6.0×3.9 6.4×4.1

3.6 4.3

0.8 0.8 0.8 1.0 1.0 0.8 0.8 0.9 1.1 1.1 0.8 0.9 1.0 1.1 1.1 0.9 0.9 1.1 1.2 1.3

6.4 6.7 7.7 9.4 10.5 6.8 7.1 8.4 10.2 11.4 7.4 8.0 9.4 11.2 12.5 8.3 8.7 10.5 12.4 14.1

5.7 6.5 8.9 14 18 6.8 7.9 11 17 23 8.2 9.9 14 21 29 10 12 17 26 36


Caledonian Industrial Cables Australian Standard V90 PVC Ordinary Duty Flexible Cord, 250/400V Application These cables are suitable for installation in dry applications only, in conduit or enclosures, such as switchboards, control panels, appliances and electrical equipment. such as radios, desk lamps and office machines, etc. Also they are used for extension leads in sizes 1 mm2 and above. Multicore cords containing an E core are suitable for a number of applications in dry and damp conditions, such as domestic appliances (washing machines, dishwashers). Leads for industrial and office equipment requiring a three-phase supply and an earth connection.

Standard PVC outer jacket Annealed copper conductor PVC insulation

AS/NZS 3191 AS/NZS 1125

Cable Construction Annealed copper conductor PVC insulation PVC outer jacket

Conductor :Annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 90째C

Insulation :V-90 PVC Colours: 1C - Red, White, Light Blue, Black 2C - Brown, Light Blue 3C - Brown, Light Blue, Green/Yellow 4C - Brown, Light Blue, White, Green/Yellow 5C - Brown, Light Blue, Orange, White, Green/Yellow

Sheath: 5V-90 PVC Colours: Grey, White, Black, Orange

13


Addison Industrial Cables Australian Standard Technical Characteristics Conductor Size mm2

0.5 0.75 1 1.5 2.5 4

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 °C

39 26 19.5 13.3 7.98 4.95

Max. AC Resistance Ohm/km @ 90 °C

49.7 33.2 24.9 17 10.2 6.31

Single Phase Voltage Drop MV/A.m

99.4 66.3 49.8 34 20.3 12.6

Cable Parameter Conductor Size

No.of cores

mm2

14

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

0.5 0.75 1.0 1.5 2.5 4

1 1 1 1 1 1

0.6 0.6 0.6 0.7 0.8 0.8

0.5 0.75

2 2

0.6 0.6

0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4 0.75 1.0 1.5 2.5 4

2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5

0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.7 0.8 0.8

Round

Flat Round

Nominal O.D.

Approx.cable weight

mm

kg/100m

-

2.2 2.4 2.5 3.0 3.7 4.2

0.9 1.2 1.5 2.1 3.4 4.8

0.8 0.8

6.0×3.9 6.4×4.1

3.6 4.3

0.8 0.8 0.8 1.0 1.0 0.8 0.8 0.9 1.1 1.1 0.8 0.9 1.0 1.1 1.1 0.9 0.9 1.1 1.2 1.3

6.4 6.7 7.7 9.4 10.5 6.8 7.1 8.4 10.2 11.4 7.4 8.0 9.4 11.2 12.5 8.3 8.7 10.5 12.4 14.1

5.7 6.5 8.9 14 18 6.8 7.9 11 17 23 8.2 9.9 14 21 29 10 12 17 26 36


Caledonian Industrial Cables Australian Standard V75 PVC Heavy Duty Flexible Cord, 0.6/1kV Application These cables are suitable for installation in switchboards and control panels where confined spaces and tortuous routes are encountered, or where flexibility is needed for hinged panels, and for fixed wiring within other enclosures where the cable is not accessible without the use of tools. they are suitable for extension leads in sizes 1 mm2 and above and suitable for supply to small industrial and commercial equipment requiring three phase power. They are also suitable for equipment requiring three phase and single phase supply and an earth connection, for example equipment containing a three phase motor and single phase pilot lights, such as industrial sweepers, vacuum cleaners, welders, etc, also suitable for use with double insulated appliances where the cord is subject to higher mechanical stress, in damp and wet conditions.

Standard AS/NZS 5000.1 AS/NZS 3191 AS/NZS 1125

PVC outer jacket Annealed copper conductor PVC insulation

Cable Construction Conductor: Annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 75°C

Insulation: V-75 PVC Colours: To AS/NZS 3191 (≤4 mm2) 1C - Red, White, Light Blue, Black 2C - Brown, Light Blue 3C - Brown, Light Blue, Green/Yellow 4C - Brown, Light Blue, White, Green/Yellow 5C - Brown, Light Blue, Orange, White, Green/Yellow

15


Addison Industrial Cables Australian Standard To AS/NZS 5000.1 (≥6 mm2) 3C - Red, Black, Green/Yellow 4C - Red, White, Black, Green/Yellow 5C - Red, White, Blue, Black, Green/Yellow

Sheath: 4V-75 PVC Colours: Black, Orange Annealed copper conductor PVC insulation PVC outer jacket

Technical Characteristics Conductor Size mm2

0.5 0.75 1.0 1.5 2.5 4.0

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 °C

39.0 26.0 19.5 13.3 7.98 4.95

Max. AC Resistance Ohm/km @ 90 °C

47.4 31.6 23.7 16.2 9.70 6.02

Single Phase Voltage Drop MV/A.m

94.7 63.2 47.5 32.3 19.4 12.0

Cable Parameter Conductor Size mm

16

No.of cores

2

0.5 0.75 1.0 1.5 2.5 4

1 1 1 1 1 1

0.75 1.0 1.5

1 1 1

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

Round without sheath 0.8 0.8 0.8 0.8 0.9 1.0 Round 0.8 1.3 0.8 1.3 0.8 1.4

Nominal O.D.

Approx.cable weight

mm

kg/100m

2.6 2.8 2.9 3.2 3.9 4.7

1.1 1.4 1.6 2.1 3.3 5.5

5.4 5.6 6.1

3.8 4.2 5.2


Caledonian Industrial Cables Australian Standard Conductor Size mm

No.of cores

2

2.5 4 0.75 1.0 1.5 2.5 4

1 1 2 2 2 2 2

0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 0.75 1.0 1.5 2.5 4

3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

0.9 1.4 1.0 1.5 0.8 1.3 0.8 1.3 0.8 1.5 0.9 1.7 1.0 1.8 Round with ground conductor 0.8 1.4 0.8 1.4 0.8 1.6 0.9 1.8 1.0 1.9 1.0 2.9 1.0 3.1 1.0 3.3 1.2 3.7 1.2 4.0 1.4 4.4 0.8 1.5 0.8 1.5 0.8 1.7 0.9 1.9 1.0 2.0 1.0 3.0 1.0 3.3 1.0 3.5 1.2 3.9 1.2 4.2 1.4 4.7 1.4 5.1 1.6 5.7 1.6 6.1 0.8 1.6 0.8 1.6 0.8 1.8 0.9 2.0 1.0 2.2

Nominal O.D.

Approx.cable weight

mm

kg/100m

8.8 9.2 10.2 12.1 13.9 16.0 20.5 24.1 29.4 32.5 37.7 9.8 10.2 11.3 13.3 15.4 17.6 22.6 26.1 32.0 35.3 41.2 48.3 53.3 60.0 10.8 11.2 12.4 14.6 17.1

10 11 15 21 30 44 69 90 140 181 241 12 14 18 26 38 54 85 122 191 246 332 460 577 731 15 17 21 30 46

6.8 7.7 8.2 8.6 9.5 11.2 13

6.9 9.4 8.4 9.3 12 17 25

17


Addison Industrial Cables Australian Standard V90 PVC Heavy Duty Flexible Cord, 0.6/1kV Application These cables are suitable for installation in switchboards and control panels where confined spaces and tortuous routes are encountered, or where flexibility is needed for hinged panels, and for fixed wiring within other enclosures where the cable is not accessible without the use of tools. they are suitable for extension leads in sizes 1 mm2 and above and suitable for supply to small industrial and commercial equipment requiring three phase power. They are also suitable for equipment requiring three phase and single phase supply and an earth connection, for example equipment containing a three phase motor and single phase pilot lights, such as industrial sweepers, vacuum cleaners, welders, etc, also suitable for use with double insulated appliances where the cord is subject to higher mechanical stress, in damp and wet conditions.

Standard AS/NZS 5000.1 AS/NZS 3191 AS/NZS 1125

Cable Construction Conductor: Annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 90°C

Insulation: V-90 PVC Colours: To AS/NZS 3191 (≤4 mm2) 1C - Red, White, Light Blue, Black 2C - Brown, Light Blue 3C - Brown, Light Blue, Green/Yellow 4C - Brown, Light Blue, White, Green/Yellow 5C - Brown, Light Blue, Orange, White, Green/Yellow

18

PVC outer jacket Annealed copper conductor PVC insulation


Caledonian Industrial Cables Australian Standard To AS/NZS 5000.1 (≥6 mm2) 3C - Red, Black, Green/Yellow 4C - Red, White, Black, Green/Yellow 5C - Red, White, Blue, Black, Green/Yellow

Sheath: 5V-90 PVC Colours: Black, Orange Annealed copper conductor PVC insulation PVC outer jacket

Technical Characteristics Conductor Size mm2

0.5 0.75 1 1.5 2.5 4

Current Carrying Capacity A

3 7.5 10 16 20 25

Max. DC Resistance Ohm/km @ 20 °C

Max. AC Resistance Ohm/km @ 90 °C

39 26 19.5 13.3 7.98 4.95

49.7 33.2 24.9 17 10.2 6.31

Single Phase Voltage Drop MV/A.m

99.4 66.3 49.8 34 20.3 12.6

Cable Parameter Conductor Size mm

No.of cores

2

0.5 0.75 1.0 1.5 2.5 4

1 1 1 1 1 1

0.75 1.0 1.5

1 1 1

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

Nominal O.D.

Approx.cable weight

mm

kg/100m

0.8 0.8 0.8 0.8 0.9 1.0

-

2.6 2.8 2.9 3.2 3.9 4.7

1.1 1.4 1.6 2.1 3.3 5.5

1.3 1.3 1.4

5.4 5.6 6.1

3.8 4.2 5.2

Round without sheath

0.8 0.8 0.8

Round

19


Addison Industrial Cables Australian Standard Conductor Size mm

20

No.of cores

2

2.5 4 0.75 1.0 1.5 2.5 4

1 1 2 2 2 2 2

0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 0.75 1.0 1.5 2.5 4

3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5

Nominal Insulation Thickness mm

0.9 1.0 0.8 0.8 0.8 0.9 1.0

Nominal Sheath Thickness mm

Approx.cable weight

1.4 1.5 1.3 1.3 1.5 1.7 1.8

mm

6.8 7.7 8.2 8.6 9.5 11.2 13

kg/100m

1.4 1.4 1.6 1.8 1.9 2.9 3.1 3.3 3.7 4.0 4.4 1.5 1.5 1.7 1.9 2.0 3.0 3.3 3.5 3.9 4.2 4.7 5.1 5.7 6.1 1.6 1.6 1.8 2.0 2.2

8.8 9.2 10.2 12.1 13.9 16.0 20.5 24.1 29.4 32.5 37.7 9.8 10.2 11.3 13.3 15.4 17.6 22.6 26.1 32.0 35.3 41.2 48.3 53.3 60.0 10.8 11.2 12.4 14.6 17.1

10 11 15 21 30 44 69 90 140 181 241 12 14 18 26 38 54 85 122 191 246 332 460 577 731 15 17 21 30 46

Round with ground conductor 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 0.8 0.9 1.0

Nominal O.D.

6.9 9.4 8.4 9.3 12 17 25


Caledonian Industrial Cables Australian Standard Single Core Flexible Power Cable, 0.6/1kV Application These cables are mainly for use in fixed applications.

Standard AS 5000.1 AS1125

Plain copper conductor

AS3808

PVC insulation

Cable Construction Conductor: Nominal 0.2mm stranded flexible plain copper wire to AS1125 Insulation: V90HT PVC to AS3808 Colours: Black, Red, Blue, White, GreenlYellow

Technical Characteristics

mm2

Electrical Resistance @20.C Ohm/km

Current Ratìng' AMPS 2 single cores

4 6 10 16 25 35 50 70 95 120

4.950 3.300 1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161

40 51 69 92 125 155 185 240 295 345

Conductor Size mm2

Voltage Orop mV 1Am at Max operatíng Temperature Single Phase

Three Phase

11 .20 7.50 4.45 2.80 1.78 1.29 0.96 0.62 0.51 0.41

9.71 6.49 3.86 2.43 1.54 1.12 0.83 0.59 0.44 0.36

21


Addison Industrial Cables Australian Standard Cable Parameter Conductor Size

No.of cores

mm2

4 6 10 16 25 35 50 70 95 120

22

1 1 1 1 1 1 1 1 1 1

mm

Nominal Insulation Thickness mm

128/0.2 192/0.2 322/0.2 511/0.2 784/0.2 1120/0.2 1568/0.2 2240/0.2 3040/0.2 3800/02

1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6

Conductor No./ OD

Nominal O.D.

Approx.cable weight

mm

kg/100m

4.8 5.4 6.3 7.3 8.8 10.2 11 .9 14.0 16.0 17.5

5.30 7.30 11.40 17.10 30.00 37.50 51.00 71 .50 97.00 119.10


Caledonian Industrial Cables Australian Standard Single Core Double Insulated Flexible Power and Welding Cable, 0.6/1kV Application These cables are used for fixed power applications, can be used in power applications,such as switchboards, busbars, transformers, welding applications ,like E and electrode leads,and automotive applications for jumper leads, battery chargers.

Standard AS 5000.1

Plain copper conductor

AS 1995 AS 1125

NBR modified PVC insulation

AS 3808

NBR modified PVC sheath

Cable Construction Conductor: Nominal 0.2mm stranded flexible plain copper wire to AS 1125 Insulation: Nitrile (NBR) Modified PVC to comply with AS3808 V90HT Insulation Colour: White Sheath: Nitrile (NBR) Modified PVC to comply with AS3808 V90HT Sheath Colours: Orange, Black - other colours available by request

Technical Characteristics Conductor Size mm2 mm2

10 16 25 35 50 70 95 120

Electrical Resistance @20.C Ohm/km

1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161

Current RatĂŹng' AMPS 2 single cores

69 92 125 155 185 240 295 345

Voltage Orop mV 1Am at Max operatĂ­ng Temperature Single Phase

4.45 2.80 1.78 1.29 0.96 0.62 0.51 0.41

Three Phase

3.86 2.43 1.54 1.12 0.83 0.59 0.44 0.36

23


Addison Industrial Cables Australian Standard Cable Parameter Conductor Size

No.of cores

mm2

10 16 25 35 50 70 95 120

24

1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6

mm

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

322/0.2 511/0.2 784/0.2 1120/0.2 1568/0.2 2240/0.2 3040/0.2 3800/0.2

1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6

1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6

Conductor No./ OD

Nominal O.D.

Approx.cable weight

mm

kg/100m

9.1 10.1 11.8 13.1 14.9 17.0 19.3 20.8

14.42 20.16 29.14 38.96 52.84 72.34 96.18 117.86


Caledonian Industrial Cables Australian Standard Flame Retardant Zero Halogen Crosslinked Thermoset Single Core X-HF110 Flexible Power Cable, 0.6/1kV Application These power cables are mainly for use in fixed applications.

Standard AS 5000.1, AS 1125, Plain copper conductor

AS 3808

X-HF-110 insulation

Cable Construction Conductor: Nominal 0 .2mm stranded flexible plain copper wire to AS 1125 Insulation: X-HF-110 to AS3808 Colours: Black, Red, Blue, White, Green/Yellow

Technical Characteristics

mm2

Electrical Resistance @20.C Ohm/km

Current RatĂŹng' AMPS 2 single cores

0.5 1.0 1.5 2.5 4.0 6.0 10 16

39 19.500 13.300 7.980 4.950 3.300 1.910 1.210

7 25 32 45 59 75 105 135

Conductor Size mm2

Voltage Drop mV 1Am at Max operating Temperature Single Phase

Three Phase

125 57.4 36.85 20.1 12.5 8.35 4.97 3.13

107 49.70 31 .90 17.40 10.80 7.23 4.30 2.71

25


Addison Industrial Cables Australian Standard

mm2

Electrical Resistance @20.C Ohm/km

Current RatĂŹng' AMPS 2 single cores

25 35 50 70 95 120

0.780 0.554 0.386 0.272 0.206 0.161

185 225 275 350 435 510

Conductor Size mm2

Voltage Drop mV 1Am at Max operating Temperature Single Phase

Three Phase

1.99 1.44 1.07 0.769 0.567 0.465

1.72 1.25 0.929 0.657 0.491 0.403

Cable Parameter Conductor Size

No.of cores

mm2

0.5 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120

26

1 1 1 1 1 1 1 1 1 1 1 1 1 1

mm

Nominal Insulation Thickness mm

16/0.2 32/0.2 30/0.25 50/0.25 12810.2 19210.2 32210.2 511/0.2 78410.2 1120/0.2 1568/0.2 2240/0.2 3040/0.2 3800/0.2

0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2

Conductor No./ OD

Nominal O.D.

Approx.cable weight

mm

kg/100m

2.40 2.80 3.10 3.60 4.20 4.80 5.80 6.90 8.70 9.60 11.20 13.20 15.00 16.70

1.10 1.50 2.00 2.90 4.40 6.60 10.50 16.10 28.80 36.30 49.50 70.10 94.20 116.80


Caledonian Industrial Cables Australian Standard Zero Halogen Flame Retardant 1100C Double Insulated Cable, 0.6/1kV Application These cables are used in power and switchboard fixed applications.

Standard AS 5000.1

Plain copper conductor

AS 1125

R -E-110 insulation

AS 3808

HFS-110-TP sheath

Cable Construction Conductor: Nominal 0 .2mm stranded flexible plain copper wire to AS1125 Insulation: R -E-110 to AS3808 Insulation Colour: White Sheath: HFS-110-TP to comply with AS3808 Sheath Colours: Orange , Black - other colours available by request

Technical Characteristics

mm2

Electrical Resistance @20.C Ohm/km

Current RatĂŹng' AMPS 2 single cores

10 16 25 35 50 70 95 120

1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161

105 135 185 225 275 350 435 510

Conductor Size mm2

Voltage Drop mV 1Am at Max operating Temperature Single Phase

Three Phase

4.97 3.13 1.99 1.44 1.07 0.769 0.567 0.465

4.30 2.70 1.72 1.24 0.92 0.65 0.48 0.39

27


Addison Industrial Cables Australian Standard Cable Parameter Conductor Size

No.of cores

mm2

10 16 25 35 50 70 95 120

28

1 1 1 1 1 1 1 1

mm

Nominal Insulation Thickness mm

Nominal Sheath Thickness mm

322/0.2 511/0.2 784/0.2 1120102 1568/0.2 2240/0.2 3040/0.2 3800/0.2

1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6

1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5

Conductor No./ OD

Nominal O.D.

Approx.cable weight

mm

kg/100m

9.1 10.1 11.8 13.1 14.9 17.0 19.3 20.8

16.30 23.40 33.60 44.60 62.50 81 .80 113.00 137.40


Caledonian Industrial Cables Australian Standard Single Core V90HT 0.6/1kV Application These cables are for electrical Interconnections.

Standard AS 3191, AS 1125, AS 3808

Cable Construction Plain/Tinned copper conductor V90HT PVC insulation

Conductor: Tinned copper wire (TCW) or plain copper wire (PCW) to AS1125 Insulation: V90HT PVC AS3808 Colours: Red, Blue, Green, Yellow, White, Black, Brown, Violet, Orange, Grey

Technical Characteristics Conductor Size mm2

0.5 0.75 1 1.5 2.5 4

Electrical Resistance @20.C Ohm/km(TCW)

40.1 26.7 20 13.7 8.2 5.1

Electrical Resistance @20.C Ohm/km(PCW)

39 26 19.5 13.3 8 5

AMP Rating

3 7.5 10 15 20 25

29


Addison Industrial Cables Australian Standard Cable Parameter Conductor Size No.of cores mm2 0.5 0.75 1 1.5 2.5 4

30

1 1 1 1 1 1 1

Conductor No./ OD

Nominal Insulation Thickness

Nominal O.D.

Approx.cable weight

mm 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3

mm 0.8 0.8 0.8 0.8 0.9 1

mm 2.6 2.8 3 3.3 3.95 4.75

kg/100m 1.1 1.4 1.7 2.2 3.5 5.3


Caledonian Industrial Cables Australian Standard Single core XLPE Insulated, PVC Sheathed Unarmoured Cables, 0.6/1kV Application These cables are used for outdoor and indoor installations in damp and wet applications. They are normally used for power distribution in urban networks, industrial plants and energy distribution. For mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage. Suitable where space is at a premium.

Standard AS/NZS 5000.1

Aluminum/annealed copper conductor

AS/NZS 3008

XLPE X-90 insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Aluminum/plain annealed copper Insulation: XLPE X-90

Insulation colour: black, other colors are available upon request Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor Nominal Area mm2

16 25 35

Current Ratings In conduit In Air A

70 99 116

Buried In Ducts A

74 96 118

In conduit In Air A

74 100 121

Buried In Ducts A

Electrical Characteristics Maximum Maximum DC AC Reactance Resistance Resistance (trefoil) @20째C @90째C Ohm/km Ohm/km Ohm/km

Aluminum 86 1.91 112 1.20 134 0.868

2.45 1.54 1.11

0.106 0.102 0.0982

3 phase Voltage Drop mV/A

4.25 2.67 1.94

31


Addison Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

In conduit In Air A

Buried In Ducts A

In conduit In Air A

50 70 95 120 150 185 240 300 400 500 630

138 176 215 253 286 330 396 457 534 616 726

139 177 209 241 273 310 369 428 487 578 663

149 193 237 281 319 374 440 -

16 25 35 50 70 95 120 150 185 240 300 400 500 630

86 121 138 171 209 253 297 341 391 462 534 616 715 836

95 123 150 182 225 268 310 353 401 471 546 621 717 813

95 127 160 193 242 286 341 385 440 523 -

32

Buried In Ducts A

Electrical Characteristics Maximum Maximum DC AC Reactance Resistance Resistance (trefoil) @20째C @90째C Ohm/km Ohm/km Ohm/km

161 0.641 198 0.443 241 0.320 278 0.253 310 0.206 358 0.164 428 0.125 482 0.100 567 0.0778 653 0.0605 770 0.0469 Copper 112 1.15 144 0.727 171 0.524 209 0.387 257 0.268 310 0.193 358 0.153 401 0.124 465 0.099 546 0.075 621 0.060 717 0.047 813 0.037 952 0.028

3 phase Voltage Drop mV/A

0.822 0.568 0.411 0.325 0.265 0.212 0.162 0.130 0.103 0.0813 0.0649

0.0924 0.0893 0.0868 0.0844 0.0844 0.0835 0.0818 0.0809 0.0802 0.0796 0.0787

1.43 0.997 0.727 0.582 0.482 0.394 0.314 0.266 0.226 0.197 0.177

1.47 0.927 0.668 0.494 0.342 0.247 0.197 0.160 0.129 0.099 0.080 0.065 0.053 0.043

0.106 0.102 0.098 0.092 0.089 0.087 0.084 0.084 0.084 0.082 0.081 0.080 0.080 0.079

2.550 1.620 1.170 0.872 0.615 0.457 0.373 0.316 0.269 0.227 0.202 0.183 0.170 0.159


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Main conductor type

16 25 35 50 70 95 120 150 185 240 300 400 500 630

7/1.70 7strands 19strands 19strands 19strands 19strands 19strands 19strands 36strands 36strands 37strands 60strands 60strands 60strands

16 25 35 50 70 95 120 150 185 240 300 400 500 630

7/1.70 7/2.14 19/1.53 19strands 19strands 19strands 19strands 19strands 36strands 36strands 37strands 60strands 60strands 91strands

Nom. insulation thickness mm

Nom. sheath thickness mm

Aluminium Conductor circular 0.7 compacted 0.9 compacted 0.9 compacted 1.0 compacted 1.1 compacted 1.1 compacted 1.2 compacted 1.4 compacted 1.6 compacted 1.7 compacted 1.8 compacted 2.0 compacted 2.2 compacted 2.4 Copper Conductor circular 0.7 circular 0.9 circular 0.9 compacted 1.0 compacted 1.1 compacted 1.1 compacted 1.2 compacted 1.4 compacted 1.6 compacted 1.7 compacted 1.8 compacted 2.0 compacted 2.2 compacted 2.4

Nom. overall diameter mm

Approx. mass kg/km

1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2 2.2

9.4 11.3 12.5 13.1 15.0 17.0 18.6 20.7 22.7 25.5 28.1 31.8 35.4 39.6

100 160 210 260 330 420 510 640 780 990 1220 1600 2000 2600

1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.2

9.4 11.3 12.5 13.1 15.0 16.8 18.6 20.6 22.7 25.6 28.4 31.7 35.4 42.4

230 320 425 550 760 1040 1305 1585 1980 2610 3340 4245 5500 7220

33


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed Unarmored Multicore control Cables 0.6/1kV Application These cables are used for control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

XLPE X-90 insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: XLPE X-90. Insulation colour: 3C – Red, White, Blue 4C - Red, White, Blue,black

Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Maximum Unenclosed In DC Buried Buried In Nominal Area Air Resistance 2 Direct A Ducts A mm A @20°C Ohm/km

10 16 25

34

68 91 121

91 118 155

68 89 118

1.83 1.15 0.727

Electrical Characteristics Maximum AC Resistance @90°C Ohm/km

Reactance Ohm/km

Three Phase Voltage Drop @90°C mV/Am

2.33 1.47 0.927

0.084 0.081 0.081

4.05 2.55 1.61


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area

Main conductor type

mm2

10 16 25 10 16 25

7/1.35 7/1.70 7/2.14 7/1.35 7/1.70 7/2.14

Nom. insulation thickness

Nom. sheath thickness

Nom. overall diameter

Approx. mass

mm

mm

mm

kg/km

1.4 1.4 1.4

15.3 17.6 21.5

435 625 950

1.4 1.4 1.4

16.7 19.2 23.6

550 800 1250

0.7 0.7 0.9 0.7 0.7 0.9

3 cores

4 cores

35


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 2 core+E Unarmored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

XLPE X-90 insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: XLPE X-90. Insulation colour: 2C + E - Red, Black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Maximum Unenclosed Buried DC Buried Nominal Area In Air In Ducts Resistance Direct A mm2 A A @20째C Ohm/km

36

Electrical Characteristics Maximum AC Resistance @90째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @90째C mV/Am

10 16 25

80 107 143

107 139 182

82 107 139

1.83 1.51 0.727

2.33 1.47 0.927

0.084 0.081 0.081

1.68 2.95 1.86

35

160

130

160

0.524

0.669

0.0786

1.35

50

195

160

190

0.387

0.494

0.0751

1.00


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Maximum Unenclosed Buried DC Buried Nominal Area In Air In Ducts Resistance 2 Direct A mm A A @20째C Ohm/km

70 95 120

250 310 360

200 240 285

235 285 325

0.268 0.193 0.153

Electrical Characteristics Maximum AC Resistance @90째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @90째C mV/Am

0.343 0.248 0.197

0.0741 0.0725 0.0713

0.703 0.520 0.423

Cable Parameter Nom. conductor area mm2

10 16 25 35 50 70 95 120

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94

0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2

4 6 6 10 16 25 25 35

Nom. earth conductor Nom. sheath Nom. overall insulation thickness diameter thickness mm mm mm

0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9

1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.6

14.9 16.6 20.2 23.0 24.1 29.8 31.6 35.5

Approx. mass kg/km

380 520 750 985 1310 1860 2415 3055

37


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 3 core+E Unarmored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1 AS/NZS 3008

Plain annealed copper conductor

AS/NZS 1125

XLPE X-90 insulation PVC sheath

Cable Construction Conductor: Plain annealed copper Insulation: XLPE X-90 Insulation colour: 3C + E – Red, White, Blue, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

10 16 25 35 50

68 91 121 149 187

91 118 155 182 219

68 89 118 144 171

38

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90°C Ohm/km @90°C @20°C Ohm/km mV/Am Ohm/km

1.83 1.15 0.727 0.524 0.387

2.33 1.47 0.927 0.669 0.494

0.084 0.081 0.081 0.079 0.075

4.05 2.55 1.61 1.17 0.868


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

70 95 120 150 185 240

237 292 305 350 405 480

268 321 250 280 325 385

214 257 275 310 355 420

Nom. earth conductor area mm2

4 6 6 10 16 25 25 35 50 70 95

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

0.268 0.193 0.153 0.124 0.0991 0.0754

0.343 0.248 0.197 0.16 0.129 0.0998

0.074 0.073 0.0713 0.0718 0.072 0.0709

0.609 0.450 0.366 0.307 0.259 0.216

Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

10 16 25 35 50 70 95 120 150 185 240

7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7

Nom. earth conductor Nom. sheath Nom. overall insulation thickness diameter thickness mm mm mm

0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 1.0 1.1 1.1

1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.6 1.7 1.8 2.0

16.0 18.3 21.8 26.9 30.7 35.9 38.0 41.8 43.0 48.4 54.5

Approx. mass kg/km

475 690 1020 1400 1900 2600 3050 4200 5250 6620 8720

39


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 4 core+E Unarmored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

XLPE X-90 insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: XLPE X-90. Insulation colour: 4C + E - Red, White, Blue, black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

10 16 25 35 50

68 91 121 149 187

91 118 155 182 219

68 89 118 144 171

40

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

1.83 1.15 0.727 0.524 0.387

2.33 1.47 0.927 0.669 0.494

0.084 0.081 0.081 0.079 0.075

4.05 2.55 1.61 1.17 0.868


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

70 95 120 150 185 240

237 292 305 350 405 480

268 321 250 280 325 385

214 257 275 310 355 420

Nom. earth conductor area mm2

4 6 6 10 16 25 25 35 50 70 95

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

0.268 0.193 0.153 0.124 0.0991 0.0754

0.343 0.248 0.197 0.160 0.129 0.0998

0.074 0.073 0.0713 0.0718 0.0720 0.0709

0.609 0.450 0.366 0.307 0.259 0.216

Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

10 16 25 35 50 70 95 120 150 185 240

7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7

Nom. earth conductor Nom. sheath Nom. overall insulation thickness diameter thickness mm mm mm

0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 1.0 1.1 1.1

1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.6 1.7 1.8 2.0

18.4 21.1 24.7 27.8 29.6 35.1 39.1 41.8 43.0 48.4 54.5

Approx. mass kg/km

620 900 1300 1750 2300 3400 4400 4200 5250 6620 8720

41


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 2 core+E Armored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

XLPE X-90 insulation Plain annealed copper conductor PVC sheath PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper Insulation: XLPE X-90. Insulation colour: 2C + E - Red, Black, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Maximum Unenclosed Buried DC Buried Nominal Area In Air In Ducts Resistance 2 Direct A mm A A @20째C Ohm/km

16 25

42

97 130

130 170

100 130

1.15 0.727

Electrical Characteristics Maximum AC Resistance @90째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @90째C mV/Am

1.47 0.927

0.0805 0.0808

2.95 1.86


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Electrical Characteristics

Maximum Unenclosed Buried DC Nominal Area Buried In Air In Ducts Resistance mm2 Direct A A A @20째C Ohm/km

Maximum AC Resistance @90째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @90째C mV/Am

35

160

205

160

0.524

0.669

0.0786

1.35

50 70 95 120

195 250 310 360

245 300 360 410

190 235 285 325

0.387 0.268 0.193 0.153

0.494 0.343 0.248 0.197

0.0751 0.0741 0.0725 0.0713

1.00 0.703 0.520 0.423

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

16 25 35 50 70 95 120

7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94

0.7 0.9 0.9 1.0 1.1 1.1 1.2

6 6 10 16 25 25 35

0.7 0.7 0.7 0.7 0.9 0.9 0.9

15.3 19.2 21.3 24.1 28.2 31.7 35.4

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

1.25 1.25 1.6 1.6 1.6 2.0 2.0

21.6 25.8 26.8 29.7 33.6 37.7 41.8

1100 1310 1765 2185 2745 3650 4600

43


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 3 core+E Armored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

PVC sheath Plain annealed copper conductor XLPE X-90 insulation PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper Insulation: XLPE X-90 Insulation colour: 3C + E – Red, White, Blue, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

16 25

83 110

110 145

83 110

44

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90°C Ohm/km @90°C @20°C Ohm/km mV/Am Ohm/km

1.15 0.727

1.47 0.927

0.0805 0.0808

2.55 1.61


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

35 50 70 95 120 150 185 240

135 170 215 265 305 350 405 480

170 205 250 300 345 385 435 500

135 160 200 240 275 310 355 420

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

0.669 0.494 0.343 0.248 0.197 0.160 0.129 0.0998

0.0786 0.0751 0.0741 0.0725 0.0713 0.0718 0.0720 0.0709

1.17 0.868 0.609 0.450 0.366 0.307 0.259 0.216

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

16 25 35 50 70 95 120 150 185 240

7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7

6 6 10 16 25 25 35 50 70 95

0.7 0.7 0.7 0.7 0.9 0.9 0.9 1.0 1.1 1.1

17.5 22.2 23.5 26.7 31.7 25.6 39.9 41.1 46.1 52.4

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

1.25 1.6 1.6 1.6 2.0 2.0 2.0 2.5 2.5 2.5

22.8 26.7 28.7 32.0 38.3 43.1 45.4 51.4 56.6 63.3

1285 1845 2315 2935 3880 5250 5765 7560 9220 11740

45


Addison Industrial Cables Australian Standard XLPE Insulated, PVC Sheathed 4 core+E Armored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor XLPE X-90 insulation PVC sheath PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper. Insulation: XLPE X-90. Insulation colour: 4C + E - Red, White, Blue, black, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

16 25

83 110

110 145

83 110

46

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

1.15 0.727

1.47 0.927

0.0805 0.0808

2.55 1.61


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

35 50 70 95 120 150 185 240

135 170 215 265 305 350 405 480

170 205 250 300 345 385 435 500

135 160 200 240 275 310 355 420

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @90째C Ohm/km @90째C @20째C Ohm/km mV/Am Ohm/km

0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

0.669 0.494 0.343 0.248 0.197 0.160 0.129 0.0998

0.0786 0.0751 0.0741 0.0725 0.0713 0.0718 0.0720 0.0709

1.17 0.868 0.609 0.450 0.366 0.307 0.259 0.216

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

16 25 35 50 70 95 120 150 185 240

7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7

6 6 10 16 25 25 35 50 70 95

0.7 0.7 0.7 0.7 0.9 0.9 0.9 1.0 1.1 1.1

19.4 22.7 24.4 27.8 33.4 36.9 38.1 42.2 52.2 58.8

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

1.6 1.6 1.6 2.0 2.0 2.5 2.5 2.5 2.5 2.5

26.3 29.6 31.5 36.5 41.8 45.8 51.7 56.9 63.1 70.1

1725 2335 2605 3860 5135 5900 9090 10410 11600 14700

47


Addison Industrial Cables Australian Standard PVC Insulated, Single Core Cable, 450/750V Application These cables are used for switchboard and control panel wiring, and for fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools.

Standard AS/NZS 5000.2

Plain copper conductor

AS 1125

PVC insulation

AS 3808

Cable Construction Conductor: Plain annealed copper. Maximum operating temperature: 90째C

Insulation: PVC V90 Insulation colour: Red/Black Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

Technical Characteristics Current Ratings Conductor Nominal Unenclosed Surrounded Buried In Area In Air by thermal Ducts mm2 A insulation A A

1 1.5 2.5 4 6 10 16

48

15 18 26 35 46 62 82

26 34 47 62 78 103 132

20 26 36 46 58 78 100

Electrical Characteristics Maximum Maximum AC DC Single Phase Resistance Reactance Resistance Voltage Drop @75째C Ohm/km @20째C mV/Am Ohm/km Ohm/km

18.1 13.6 7.41 4.61 3.08 1.83 1.15

27.0 17.3 9.45 5.88 3.93 2.33 1.47

0.168 0.157 0.143 0.137 0.128 0.118 0.111

54.0 34.6 18.9 11.8 7.86 4.68 2.94


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

1.0

1/1.13

4.1

30

1.5

7/0.50

0.6

0.9

4.4

35

2.5

7/0.67

0.7

1

5.1

55

4

7/0.85

0.8

1.1

6.0

80

6

7/1.04

1.0

1.1

6.6

100

10

7/1.35

1.0

1.2

7.8

145

16

7/1.70

1.0

1.3

9.1

225

0.6

0.9

49


Addison Industrial Cables Australian Standard PVC Insulated, Round Cables, 450/750V Application These cables are used for control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where not subject to mechanical damage.

Standard AS/NZS 5000.2 AS 1125 AS 3808

Cable Construction

Plain annealed copper conductor PVC insulation PVC sheath

Conductor: Plain annealed copper. Maximum operating temperature: 90째C

Insulation: PVC V90. Insulation colour: 2C: Red, Black 3C: Red, White & Blue 4C: Red, White, Blue, & Black 7-37C: White (Numbered)

Sheath: Polyvinylchloride compound PVC 5V90 Sheath colour: Black, other colors are available upon request

50


Caledonian Industrial Cables Australian Standard Technical Characteristics Conductor Nominal Area mm2

Current Ratings Unenclosed In Air A

Maximum Buried DC Buried In direct Resistance Ducts A A @20°C Ohm/km

Electrical Characteristics Maximum AC Resistance @75°C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75°C mV/Am

2 cores

1.5

21

31

24

13.6

16.5

0.111

33.0

2.5

30

44

34

7.41

9.01

0.102

18.0

Conductor Nominal Area mm2

Current Ratings Unenclosed In Air A

Maximum Buried DC Buried In direct Resistance Ducts A A @20°C Ohm/km

Electrical Characteristics Maximum AC Resistance @75°C Ohm/km

Reactance Ohm/km

Three Phase Voltage Drop @75°C mV/Am

3 cores

1.5

17

26

21

13.6

16.5

0.111

28.6

2.5

25

37

29

7.41

9.01

0.102

15.6

4

33

48

37

4.61

5.61

0.102

9.71

6

42

61

47

3.08

3.75

0.097

6.49

4 cores 1.5

17

26

21

13.6

16.5

0.111

28.6

2.5

25

37

29

7.41

9.01

0.102

15.6

4

33

48

37

4.61

5.61

0.102

9.71

6

42

61

47

3.08

3.75

0.097

6.49

7-37 cores 1.0

14

21

17

18.1

25.8

0.119

51.6

1.5

17

26

21

13.6

16.5

0.111

33.0

2.5

25

37

29

7.41

9.01

0.102

18.0

Cable Parameter 2 cores Nom. conductor area mm2

1.5 2.5

Conductor No./ OD

7/0.50 7/0.67

Nom. insulation thickness mm

0.6 0.7

Nom. sheath thickness mm

0.9 1

Nom. overall diameter mm

8.0 9.6

Approx. mass kg/km

95 140

51


Addison Industrial Cables Australian Standard 3 cores Nom. conductor area mm2

Conductor No./ OD

1.5 2.5 4 6

7/0.50 7/0.67 7/0.85 7/1.04

Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

8.5 10.1 11.7 13.2

120 170 240 300

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

9.2 11.4 12.4 13.8

130 210 280 330

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

10.0 11.4 13.3

150 195 300

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

0.6 0.7 0.8 1.0

0.9 1 1.1 1.1

4 cores

1.5 2.5 4 6

7/0.50 7/0.67 7/0.85 7/1.04

Nom. conductor area mm2

Conductor No./ OD

0.6 0.7 0.8 1.0

0.9 1 1.1 1.1

7 cores

1.0 1.5 2.5

1/1.13 7/0.50 7/0.67

0.6 0.6 0.7

0.9 0.9 1

12 cores Nom. conductor area mm2

1.0 1.5 2.5

52

Conductor No./ OD

1/1.13 7/0.50 7/0.67

0.6 0.6 0.7

0.9 0.9 1

12.9 15.0 17.5

240 320 490


Caledonian Industrial Cables Australian Standard 19 cores Nom. conductor area mm2

1.0 1.5 2.5

Conductor No./ OD

1/1.13 7/0.50 7/0.67

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

14.9 16.8 21.0

350 450 760

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

17.9 21.1 24.8

480 670 1030

Nom. insulation thickness mm

Nom. sheath thickness mm

Nom. overall diameter mm

Approx. mass kg/km

0.6 0.6 0.7

0.9 0.9 1

27 cores Nom. conductor area mm2

1.0 1.5 2.5

Conductor No./ OD

1/1.13 7/0.50 7/0.67

0.6 0.6 0.7

0.9 0.9 1

37 cores Nom. conductor area mm2

1.0 1.5 2.5

Conductor No./ OD

1/1.13 7/0.50 7/0.67

0.6 0.6 0.7

0.9 0.9 1

21.2 22.7 27.9

690 840 1380

53


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 2 core+E Round Cables, 450/750V Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

PVC insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 2C + E - Red, Black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Unenclosed Nominal Area In Air 2 mm A

54

1.5

21

2.5

Maximum Buried Buried DC Direct In Ducts Resistance A A @20째C Ohm/km

Electrical Characteristics Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75째C mV/Am

31

24

13.6

16.5

0.111

33.0

30

44

34

7.41

9.01

0.102

18.0

4

39

57

44

4.61

5.61

0.102

11.2

6

50

72

56

3.08

3.75

0.097

7.50


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

Nom. sheath thickness mm

1.5

7/0.50

1.5

0.9

8.5

110

2.5

7/0.67

0.7

2.5

1

10.1

170

4

7/0.85

0.8

2.5

1.1

11.2

220

6

7/1.04

1.0

2.5

1.1

12.3

250

0.6

Nom. overall Approx. mass diameter kg/km mm

55


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 3 core+E Round Cables, 450/750V Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1 AS/NZS 3008

Plain annealed copper conductor

AS/NZS 1125

PVC insulation PVC sheath

Cable Construction Conductor: Plain annealed copper Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 3C + E – Red, White, Blue, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5

17

26

21

2.5

25

37

4

33

6

42

56

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75°C Ohm/km @75°C @20°C Ohm/km mV/Am Ohm/km

13.6

16.5

0.111

28.6

29

7.41

9.01

0.102

15.6

48

37

4.61

5.61

0.102

9.71

61

47

3.08

3.75

0.0967

6.49


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

Nom. sheath thickness mm

1.5

7/0.50

1.5

0.9

9.2

130

2.5

7/0.67

0.7

2.5

1

11.4

210

4

7/0.85

0.8

2.5

1.1

12.4

280

6

7/1.04

1.0

2.5

1.1

13.8

330

0.6

Nom. overall Approx. mass diameter kg/km mm

57


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 4 core+E Round Cables, 450/750V Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

PVC insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 4C + E - Red, White, Blue, black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5

17

26

21

2.5

25

37

4

33

6

42

58

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

13.6

16.5

0.111

28.6

29

7.41

9.01

0.102

15.6

48

37

4.61

5.61

0.102

9.71

61

47

3.08

3.75

0.0967

6.49


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

Nom. sheath thickness mm

1.5

7/0.50

1.5

0.9

10.0

145

2.5

7/0.67

0.7

2.5

1

12.1

230

4

7/0.85

0.8

2.5

1.1

13.6

320

6

7/1.04

1.0

2.5

1.1

15.9

430

0.6

Nom. overall Approx. mass diameter kg/km mm

59


Addison Industrial Cables Australian Standard PVC Insulated, 2 Cores Flat Cables, 450/750V Application These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage. Suitable for lighting and applications not requiring earth.

Standard AS/NZS 5000.2

PVC outer jacket Plain annealed copper conductor PVC insulation

AS 1125 AS 3808

Cable Construction Conductor: Plain annealed copper. Maximum operating temperature: 90째C Insulation: PVC V90

Insulation colour: 2C cable: Red, Black Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

Technical Characteristics Current Ratings Conductor Nominal Area Unenclosed In Air mm2 A

1 1.5 2.5 4 6

60

16 21 30 39 50

Electrical Characteristics Maximum Surrounded Maximum AC Buried In DC by thermal Resistance Reactance Ducts Resistance insulation @75째C Ohm/km A @20째C A Ohm/km Ohm/km

8 10 15 19 25

19 24 34 44 56

18.1 13.6 7.41 4.61 3.08

27.0 17.3 9.45 5.88 3.93

0.119 0.111 0.102 0.102 0.0967

Single Phase Voltage Drop mV/Am

54.0 34.6 18.9 11.8 7.86


Caledonian Industrial Cables Australian Standard Current Ratings Conductor Nominal Area Unenclosed In Air mm2 A

10 16

68 91

Electrical Characteristics Maximum Surrounded Maximum AC Buried In DC by thermal Resistance Reactance Ducts Resistance insulation @75째C Ohm/km A @20째C A Ohm/km Ohm/km

34 46

75 97

1.83 1.15

2.33 1.47

0.0906 0.0861

Single Phase Voltage Drop mV/Am

4.68 2.94

Cable Parameter Nom. conductor area mm2

1.0 1.5 2.5 4 6 10 16

Conductor No./ OD

1/1.13 7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70

Nom. insulation thickness mm

0.6 0.6 0.7 0.8 1.0 1.0 1.0

Nom. sheath thickness mm

0.9 0.9 1 1.1 1.1 1.2 1.3

Nom. overall diameter mm

Min

Max

6.5x4.1 7.2x4.5 8.7x5.4 10.3x6.3 11.5x6.8 14.1x8.3 16.4x9.5

6.9x4.4 7.6x4.8 9.2x5.7 10.9x6.6 12.0x7.2 14.7x8.7 17.1x10.0

Approx. mass kg/km

50 65 105 145 195 295 435

61


Addison Industrial Cables Australian Standard PVC Insulated, 3 Cores Flat Cables, 450/750V Application These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage. Suitable for two way or intermediate switching applications.

Standard AS/NZS 5000.2

PVC insulation Plain annealed copper conductor PVC outer jacket

AS 1125 AS 3808

Cable Construction Conductor: Plain annealed copper. Maximum operating temperature: 90째C

Insulation: PVC V90 Insulation colour: 3C cable: Red, White, Blue Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

Technical Characteristics Current Ratings Electrical Characteristics Conductor Maximum Maximum AC Nominal Unenclosed In Surrounded Buried In DC by thermal Resistance Reactance Area Air Ducts Resistance 2 insulation @75째C Ohm/km mm A A @20째C A Ohm/km Ohm/km

1 1.5 2.5 4

62

14 17 25 33

7 9 13 17

17 21 29 37

18.1 13.6 7.41 4.61

27.0 17.3 9.45 5.85

0.119 0.111 0.102 0.102

Three Phase Voltage Drop mV/Am

54.1 34.7 19.0 11.8


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. sheath thickness mm

1.0

1/1.13

0.6

1.5

7/0.50

2.5 4

Nom. overall diameter mm

Approx. mass kg/km

Min

Max

0.9

8.8x4.1

9.3x4.4

75

0.6

0.9

9.9x4.5

10.4x4.8

95

7/0.67

0.7

1

12.1x5.4

12.7x5.7

145

7/0.85

0.8

1.1

14.7x6.4

15.4x6.7

220

63


Addison Industrial Cables Australian Standard PVC Insulated, 4 Cores Flat Cables, 450/750V Application These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage.

Standard AS/NZS 5000.2 AS 1125 AS 3808

Cable Construction PVC insulation Plain annealed copper conductor PVC outer jacket

Conductor: Plain annealed copper. Maximum operating temperature: 90째C

Insulation: PVC V90 Insulation colour: 4C cable: Red, White, Blue, Black Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

64


Caledonian Industrial Cables Australian Standard Technical Characteristics Current Ratings

Conductor Nominal Area mm2

Unenclosed In Air A

1

14

1.5

Electrical Characteristics

Maximum Surrounded Maximum AC Buried In DC by thermal Resistance Ducts Resistance insulation @75째C A @20째C A Ohm/km Ohm/km

Reactance Ohm/km

Three Phase Voltage Drop mV/Am

7

17

18.1

27.0

0.119

46.8

17

9

21

13.6

17.3

0.111

30.0

2.5

25

13

29

7.41

9.45

0.102

16.4

4

33

17

37

4.61

5.88

0.102

10.2

Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

Nom. sheath thickness mm

1.0

1/1.13

0.6

1.5

7/0.50

2.5 4

Nom. overall diameter mm

Approx. mass kg/km

Min

Max

0.9

11.1x4.1

11.8x4.4

95

0.6

0.9

12.6x4.5

13.3x4.8

120

7/0.67

0.7

1

15.6x5.4

16.4x5.7

190

7/0.85

0.8

1.1

18.8x6.4

19.7x6.7

290

65


Addison Industrial Cables Australian Standard PVC Insulated, 2 Core + E Flat Cables, 450/750V Application These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage. Suitable for single phase applications requiring neutral and E.

Standard PVC insulation Plain annealed copper conductor PVC outer jacket

AS/NZS 5000.2, AS 1125, AS 3808

Cable Construction Conductor: Plain annealed copper Maximum operating temperature: 90째C

Insulation: PVC V90 Insulation colour: Red, Black, Green/yellow Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

Technical Characteristics Current Ratings

Conductor Nominal Area mm2

Unenclosed In Air A

1 1.5 2.5 4 6 10 16

16 21 30 39 50 68 91

66

Electrical Characteristics

Surrounded Maximum Maximum AC Buried In by thermal DC Resistance Resistance Reactance Ducts insulation @20째C @75째C Ohm/km A A Ohm/km Ohm/km

8 10 15 19 25 34 46

19 24 34 44 56 75 97

18.1 13.6 7.41 4.61 3.08 1.83 1.15

27.0 17.3 9.45 5.88 3.93 2.33 1.47

0.119 0.111 0.102 0.102 0.0967 0.0906 0.0861

Single Phase Voltage Drop mV/Am

54.1 34.7 19.0 11.8 7.9 4.7 2.95


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

1.0

1/1.13

1.5

7/0.50

2.5

Nom. insulation thickness mm

0.6

earth Nom. sheath conductor thickness area mm 2 mm

Nom. overall diameter mm Min

Max

Approx. mass kg/km

1.0

0.9

8.8x4.1

9.3x4.4

75

0.6

1.5

0.9

10.0x4.5

10.0x4.5

95

7/0.67

0.7

2.5

1

12.1x5.4

12.7x5.7

145

4

7/0.85

0.8

2.5

1.1

13.7x6.3

14.4x6.6

220

6

7/1.04

1.0

2.5

1.1

14.9x6.9

15.6x7.3

290

10

7/1.35

1.0

4

1.2

18.9x8.3

19.0x8.7

440

16

7/1.70

1.0

6

1.3

21.0x9.5

22.0x10.0

645

67


Addison Industrial Cables Australian Standard PVC Insulated, 3 Core + E Flat Cables, 450/750V Application These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial installations where not subject to mechanical damage. Suitable for balanced three phase applications with E.

Standard AS/NZS 5000.2,

PVC insulation Plain annealed copper conductor PVC outer jacket

AS 1125, AS 3808

Cable Construction Conductor: Plain annealed copper Maximum operating temperature: 90째C

Insulation: PVC V90 Insulation colour: Red, White, Blue, Green/yellow Sheath: Polyvinylchloride compound PVC 3V90 Sheath colour: White, other colors are available upon request

Technical Characteristics Current Ratings

Conductor Nominal Area mm2

Unenclosed In Air A

1 1.5 2.5 4 6 10 16

14 17 25 33 42 58 78

68

Maximum Surrounded Buried DC by thermal In Ducts Resistance insulation A @20째C A Ohm/km

7 9 13 17 22 29 39

17 21 29 37 47 63 81

18.1 13.6 7.41 4.61 3.08 1.83 1.15

Electrical Characteristics Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

27.0 17.3 9.45 5.88 3.93 2.33 1.47

0.119 0.111 0.102 0.102 0.0967 0.0906 0.0861

Three Phase Voltage Drop mV/Am

46.8 30.0 16.4 10.2 6.8 4.05 2.55


Caledonian Industrial Cables Australian Standard Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

earth conductor area mm2

Nom. sheath thickness mm

1.0

1/1.13

1.5

7/0.50

0.6

2.5

7/0.67

4

Nom. overall diameter mm Min

Max

Approx. mass kg/km

0.9

11.1x4.1

11.8x4.4

95

1.5

0.9

12.6x4.5

13.3x4.8

120

0.7

2.5

1

15.6x5.4

16.4x5.7

190

7/0.85

0.8

2.5

1.1

17.7x6.2

18.6x6.7

290

6

7/1.04

1.0

2.5

1.1

19.5x6.9

20.4x7.3

370

10

7/1.35

1.0

4

1.2

24.0x8.2

24.5x8.7

540

16

7/1.70

1.0

6

1.3

27.8x9.5

29.1x10.0

820

0.6

1.0

69


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 2 core+E Unarmored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

PVC insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 2C + E - Red, Black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

1.5 2.5 4

18 26 34

6 10

70

Maximum Buried Buried DC Direct In Ducts Resistance A A @20째C Ohm/km

Electrical Characteristics Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75째C mV/Am

14 20 26

22 31 40

13.6 7.41 4.61

16.5 9.01 5.61

0.111 0.102 0.102

33.0 18.0 11.2

44

34

51

3.08

3.75

0.0967

7.50

60

47

68

1.83

2.23

0.0906

4.46


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Unenclosed Nominal Area In Air 2 mm A

16 25 35 50 70 95

80 105 130 160 200 250

Maximum Buried Buried DC Direct In Ducts Resistance A A @20째C Ohm/km

63 88 105 125 155 190

88 115 140 165 205 250

Electrical Characteristics Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75째C mV/Am

1.15 0.727 0.524 0.387 0.268 0.193

1.40 0.884 0.638 0.471 0.327 0.236

0.0861 0.0853 0.0826 0.0797 0.0770 0.0766

2.81 1.78 1.28 0.957 0.673 0.498

Nom. earth conductor area mm2

1.5 2.5 2.5 2.5 4 6 6 10 16 25 25

Nom. earth conductor insulation thickness mm

Cable Parameter Nom. conductor area mm2

Conductor No./ OD

Nom. insulation thickness mm

1.5 2.5 4 6 10 16 25 35 50 70 95

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6

0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.2 1.2

Nom. overall Approx. mass diameter kg/km mm

10.6 11.6 13.1 14.2 15.9 17.9 21.6 22.8 25.8 30.4 34.8

160 220 295 335 440 620 840 1090 1465 1900 2500

71


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 3 core+E Unarmored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1 AS/NZS 3008

Plain annealed copper conductor

AS/NZS 1125

PVC insulation PVC sheath

Cable Construction Conductor: Plain annealed copper Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 3C + E – Red, White, Blue, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5 2.5 4 6 10

15 22 29 37 51

13 18 24 31 42

19 26 34 43 57

72

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75°C Ohm/km @75°C @20°C Ohm/km mV/Am Ohm/km

13.6 7.41 4.61 3.08 1.83

16.5 9.01 5.61 3.75 2.23

0.111 0.102 0.102 0.0967 0.0906

28.6 15.6 9.71 6.49 3.86


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

16 25 35 50 70 95 120 150 185 240

68 91 110 135 170 215 245 280 325 385

56 79 92 110 140 165 195 225 260 305

74 96 115 140 175 210 240 270 310 370

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

1.40 0.884 0.638 0.471 0.327 0.236 0.188 0.153 0.123 0.0955

0.0861 0.0853 0.0826 0.0797 0.0770 0.0766 0.0743 0.0745 0.0744 0.0735

2.43 1.54 1.11 0.829 0.583 0.431 0.351 0.296 0.251 0.210

Cable Parameter Nom. conductor area mm2

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2

1.5 2.5 2.5 2.5 4.0 6.0 6.0 6.0 16 25 25 35 50 70 95

Nom. earth conductor insulation thickness mm

0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6

Nom. overall Approx. mass diameter kg/km mm

11.5 12.6 14.2 15.4 17.5 19.8 23.5 25.0 30.4 33.0 38.4 40.6 45.2 50.3 57.2

190 250 350 400 605 825 1190 1535 2175 2870 3880 4640 5500 6930 9170

73


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 4 core+E Unarmored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

PVC insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 4C + E - Red, White, Blue, black, Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Black, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5 2.5 4 6 10

15 22 29 37 51

13 18 24 31 42

19 26 34 43 57

74

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

13.6 7.41 4.61 3.08 1.83

16.5 9.01 5.61 3.75 2.23

0.111 0.102 0.102 0.0967 0.0906

28.6 15.6 9.71 6.49 3.86


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

16 25 35 50 70 95 120 150 185 240

68 91 110 135 170 215 245 280 325 385

56 79 92 110 140 165 195 225 260 305

74 96 115 140 175 210 240 270 310 370

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

1.40 0.884 0.638 0.471 0.327 0.236 0.188 0.153 0.123 0.0955

0.0861 0.0853 0.0826 0.0797 0.0770 0.0766 0.0743 0.0745 0.0744 0.0735

2.43 1.54 1.11 0.829 0.583 0.431 0.351 0.296 0.251 0.210

Cable Parameter Nom. conductor area mm2

1.5 2.5 4 6 10 16 25 35* 50* 70* 95* 120* 150* 185* 240*

Conductor No./ OD

Nom. insulation thickness mm

Nom. earth conductor area mm2

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2

1.5 2.5 2.5 2.5 4.0 6.0 6.0 10 16 25 25 35 50 70 95

Nom. earth conductor insulation thickness mm

0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6

Nom. overall Approx. mass diameter kg/km mm

12.4 13.7 15.6 16.8 20.3 22.9 26.9 27.7 33.5 37.0 44.8 48.5 51.0 56.7 64.6

225 280 400 510 730 1015 1540 1930 2470 3710 5025 5870 7150 8990 11910

75


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 2 core+E Armored Cables, 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

PVC insulation Plain annealed copper conductor PVC sheath PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper Insulation: Polyvinylchloride compound PVC V-90. Insulation colour: 2C + E - Red, Black, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Unenclosed Nominal Area In Air 2 mm A

1.5 2.5

76

18 26

Maximum Buried Buried DC Direct In Ducts Resistance A A @20째C Ohm/km

28 40

22 31

13.6 7.41

Electrical Characteristics Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75째C mV/Am

16.5 9.01

0.111 0.102

33.0 18.0


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

4

34

6 10 16 25 35 50 70 95

44 60 80 105 130 160 200 250

Electrical Characteristics

Maximum Buried Buried DC Direct In Ducts Resistance A A @20째C Ohm/km

Maximum AC Resistance @75째C Ohm/km

Reactance Ohm/km

Single Phase Voltage Drop @75째C mV/Am

52

40

4.61

5.61

0.102

11.2

65 87 115 145 180 210 260 310

51 68 88 115 140 165 205 250

3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193

3.75 2.23 1.40 0.884 0.638 0.471 0.327 0.236

0.0967 0.0906 0.0861 0.0853 0.0826 0.0797 0.0770 0.0766

7.50 4.46 2.81 1.78 1.28 0.957 0.673 0.498

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

1.5 2.5 4 6 10 16 25 35 50 70 95

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6

1.5 2.5 2.5 2.5 4.0 6.0 6.0 10 16 25 25

0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.2 1.2

9.0 10.0 11.4 12.5 14.2 16.3 20.0 21.7 24.7 28.7 32.6

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

0.9 0.9 0.9 0.9 1.25 1.25 1.6 1.6 1.6 2.0 2.0

14.5 15.6 16.9 18.0 20.5 22.5 27.0 28.1 31.3 35.1 40.4

470 490 690 765 937 1295 1600 1775 2215 2880 3910

77


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 3 core+E Armored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

PVC sheath Plain annealed copper conductor PVC insulation PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper Insulation: Polyvinylchloride compound PVC V-90 Insulation colour: 3C + E – Red, White, Blue, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5 2.5

15 22

24 34

19 26

78

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75°C Ohm/km @75°C @20°C Ohm/km mV/Am Ohm/km

13.6 7.41

16.5 9.01

0.111 0.102

28.6 15.6


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

4 6 10 16 25 35 50 70 95 120 150 185 240

29 37 51 68 91 110 135 170 215 245 280 325 385

44 55 74 96 125 150 180 220 265 300 335 380 440

34 43 57 74 96 115 140 175 210 240 270 310 370

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75C @20째C Ohm/km mV/Am Ohm/km

4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

5.61 3.75 2.23 1.40 0.884 0.638 0.471 0.327 0.236 0.188 0.153 0.123 0.0955

0.102 0.0967 0.0906 0.0861 0.0853 0.0826 0.0797 0.0770 0.0766 0.0743 0.0745 0.0744 0.0735

9.71 6.49 3.86 2.43 1.54 1.11 0.829 0.583 0.431 0.351 0.296 0.251 0.210

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2

1.5 2.5 2.5 2.5 4.0 6.0 6.0 10 16 25 25 35 50 70 95

0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6

9.8 10.9 12.5 13.7 15.8 18.1 21.8 23.8 26.7 31.4 35.9 39.5 43.2 48.0 54.9

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

0.9 0.9 1.25 1.25 1.25 1.6 1.6 1.6 2.0 2.0 2.5 2.5 2.5 2.5 2.5

15.4 16.5 18.8 20.0 22.1 25.1 28.8 30.3 34.1 39.8 43.9 47.5 53.4 58.7 66.0

400 545 770 880 1160 1560 2100 2480 3140 4455 5520 6790 7970 9660 12330

79


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed 4 core+E Armored Cables 0.6/1kV Application These cables are used for mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor PVC insulation PVC sheath PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90. Insulation colour: 4C + E - Red, White, Blue, black, Green/yellow Bedding: Polyvinylchloride compound PVC 5V-90 Bedding colour: Black Armour: Galvanised Steel Wire Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor

Current Ratings

Electrical Characteristics

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

1.5 2.5

15 22

24 34

19 26

80

Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

13.6 7.41

16.5 9.01

0.111 0.102

28.6 15.6


Caledonian Industrial Cables Australian Standard Conductor

Current Ratings

Nominal Area mm2

Unenclosed In Air A

Buried Direct A

Buried In Ducts A

4 6 10 16 25 35 50 70 95 120 150 185 240

29 37 51 68 91 110 135 170 215 245 280 325 385

44 55 74 96 125 150 180 220 265 300 335 380 440

34 43 57 74 96 115 140 175 210 240 270 310 370

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754

5.61 3.75 2.23 1.40 0.884 0.638 0.471 0.327 0.236 0.188 0.153 0.123 0.0955

0.102 0.0967 0.0906 0.0861 0.0853 0.0826 0.0797 0.0770 0.0766 0.0743 0.0745 0.0744 0.0735

9.71 6.49 3.86 2.43 1.54 1.11 0.829 0.583 0.431 0.351 0.296 0.251 0.210

Cable Parameter Nom. earth Nom. Nom. Nom. Nom. earth conductor diameter conductor Conductor insulation conductor insulation over area No./ OD thickness area thickness bedding 2 2 mm mm mm mm mm

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240

7/0.50 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.65 19/1.89 19/2.24 19/2.65 19/2.94 19/3.28 37/2.65 37/2.94

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2

1.5 2.5 2.5 2.5 4.0 6.0 6.0 10 16 25 25 35 50 70 95

0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6

10.7 12.0 13.9 15.9 17.5 21.2 24.4 26.1 30.4 35.1 39.6 43.9 48.5 54.3 61.6

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

0.9 0.9 1.25 1.25 1.6 1.6 1.6 1.6 2.0 2.0 2.5 2.5 2.5 2.5 3.15

16.3 17.6 20.2 22.2 24.5 28.2 32.2 33.3 38.8 43.7 49.6 54.1 59.1 65.4 74.7

545 635 900 1050 1490 1810 2530 2990 4140 5470 7250 9090 9900 12110 16320

81


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed Multi-core+E Control Cables 0.6/1kV Application These cables are used for control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where not subject to mechanical damage.

Standard AS/NZS 5000.1

Plain annealed copper conductor

AS/NZS 3008

PVC insulation

AS/NZS 1125

PVC sheath

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90. Insulation colour: White(black letter numbered), Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor Nominal Area mm2

Current Ratings Unenclosed In Air A

Buried Direct A

Buried In Ducts A

2C+E 3-50C+ E

18 15

14 13

22 19

2C+E 3-50C+ E

26 22

20 18

31 26

82

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

1.5mm2 2.5mm2

13.6 13.6

16.5 16.5

0.111 0.111

33.0 33.0

7.41 7.41

9.01 9.01

0.102 0.102

18.0 18.0


Caledonian Industrial Cables Australian Standard Cable Parameter No. of Cores

Conductor No./ OD

Nom. insulation thickness mm

2C+ E 3C+ E 4C+ E 6C+ E 8C+ E 10C+ E 12C+ E 15C+ E 20C+ E 25C+ E 30C+ E 40C+ E 50C+ E

7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

2C+ E 3C+ E 4C+ E 6C+ E 8C+ E 10C+ E 12C+ E 15C+ E 20C+ E 25C+ E 30C+ E 40C+ E 50C+ E

7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Nom. earth conductor area mm2

1.5mm2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5mm2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5

Nom. earth conductor insulation thickness mm

Nom. overall Approx. mass diameter kg/km mm

0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6

10.6 11.5 12.4 13.4 16.6 16.9 17.9 18.9 20.7 22.9 25.8 28.0 30.8

165 190 215 275 340 375 435 525 680 785 845 1190 1290

0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7

11.6 12.6 13.7 14.8 18.4 19.9 20.0 21.0 25.7 26.3 28.3 33.5 35.0

210 250 285 365 455 530 605 715 950 1095 1200 1565 1925

83


Addison Industrial Cables Australian Standard PVC Insulated, PVC Sheathed Multicore+E Armored Control Cables 0.6/1kV Application These cables are used for control circuits unenclosed, enclosed in conduit, buried direct or in underground ducts for commercial, industrial, mining and electricity authority systems where mechanical damage may occur.

Standard AS/NZS 5000.1

Plain annealed copper conductor PVC insulation PVC sheath PVC bedding Galvanised steel wire armour

AS/NZS 3008 AS/NZS 1125

Cable Construction Conductor: Plain annealed copper. Insulation: Polyvinylchloride compound PVC V-90. Insulation colour: White(black letter numbered), Green/yellow Sheath: Polyvinylchloride compound PVC 5V-90 Sheath colour: Orange, other colors are available upon request

Technical Characteristics Conductor Nominal Area mm2

Current Ratings Unenclosed In Air A

Buried Direct A

Buried In Ducts A

2C+E 3-50C+ E

18 15

14 13

22 19

2C+E 3-50C+ E

26 22

20 18

31 26

84

Electrical Characteristics Maximum Maximum AC Three Phase DC Resistance Reactance Voltage Drop Resistance @75째C Ohm/km @75째C @20째C Ohm/km mV/Am Ohm/km

1.5mm2 2.5mm2

13.6 13.6

16.5 16.5

0.111 0.111

33.0 33.0

7.41 7.41

9.01 9.01

0.102 0.102

18.0 18.0


Caledonian Industrial Cables Australian Standard Cable Parameter No. of Cores

Nom. earth Nom. Nom. Nom. earth conductor diameter Conductor insulation conductor insulation over No./ OD thickness area thickness bedding mm mm2 mm mm

2C+ E 3C+ E 4C+ E 6C+ E 8C+ E 10C+ E 12C+ E 15C+ E 20C+ E 25C+ E 30C+ E 40C+ E 50C+ E

7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

2C+ E 3C+ E 4C+ E 6C+ E 8C+ E 10C+ E 12C+ E 15C+ E 20C+ E 25C+ E 30C+ E 40C+ E 50C+ E

7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5

1.5mm2 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 2.5mm2 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7

Armour diameter mm

Nom. overall diameter mm

Approx. mass kg/km

9.0 9.8 10.7 11.7 13.6 14.9 16.2 17.1 19.0 21.7 23.5 26.4 28.9

0.90 0.90 0.90 0.90 1.25 1.25 1.25 1.60 1.60 1.60 1.60 1.60 1.60

14.5 15.4 16.3 17.3 19.9 21.2 22.5 23.4 26.0 28.7 30.4 34.8 36.1

405 440 550 690 770 920 1010 1110 1535 1670 1840 2260 2400

10.0 10.9 12.0 13.1 15.3 16.8 18.3 19.3 21.5 24.6 26.6 30.4 33.3

0.90 0.90 0.90 1.25 1.25 1.25 1.60 1.60 1.60 1.60 1.60 2.0 2.0

11.6 12.6 13.7 14.8 18.4 19.9 20.0 21.0 25.7 26.3 28.3 33.5 35.0

210 250 285 365 455 530 605 715 950 1095 1200 1565 1925

85


Addison Industrial Cables Australian Standard Flexible VSD/EMC Cables, 0.6/1kV Application These cables are used for applications that require Electromagnetic Compatibilit (EMC), to minimise any interference or disturbance, propagation and reception of electromagnetic energy with reference to unwanted effects, and suitable for Variable Speed Drive equipment or other application requiring screened cable.

Standard AS/NZS 5000.1, AS 1125, AS 3808

Cable Construction TYPE 1 Tinned copper braid Non-hygroscopic material filler Earth conductor PVC insulation Plain annealed copper conductor PVC bedding PVC outer sheath

Conductor: Plain annealed copper, class 5 strands Insulation: Flame retardant polyvinyl chloride PVC V75 Insulation colour: 3 cores + E: Red, White, Blue + Green/Yellow 4 cores + E: Red, White, Blue, Black + Green/Yellow

Filler: Non-hygroscopic material Bedding: Flame retardant polyvinyl chloride PVC V75 Screen: Tinned annealed copper braid Sheath: Flame retardant polyvinyl chloride PVC V75 Sheath colour: Transparent

86


Caledonian Industrial Cables Australian Standard TYPE 2 Plain copper braid Non-hygroscopic material filler Earth conductor XLPE insulation Plain annealed copper conductor TPE bedding TPE outer sheath

Conductor: Plain annealed copper, class 5 strands Insulation: Cross -linked polyethylene (XLPE) Insulation colour: 3 cores + E: Red, White, Blue + Green/Yellow 4 cores + E: Red, White, Blue, Black + Green/Yellow

Filler: Non-hygroscopic material Bedding: Thermoplastic elastomer (TPE) Screen: Plain annealed copper braid Sheath: Thermoplastic elastomer (TPE) Sheath colour: Black

Technical Characteristics ELECTRICALCHARACTERISTICS Nom. Max. wires DC AC AC conductor Dia. Fine- resistance resistance resistance area wire strand at 20ºC at 75ºC at 90ºC mm² mm Ohm/km Ohm/km Ohm/km

3-Phase at 75ºC Voltage Drop mV/A.m

3-Phase at 90ºC Voltage Drop mV/A.m

29.4

0.118

0.118

28.0

Reactance Reactance Type 1 Type 2 cable cable Ohm/km Ohm/km

1.5

0.25

13.3

16.2

17.0

2.5

0.25

7.98

9.7

10.2

16.8

17.6

0.112

0.112

4

0.30

4.95

6.02

6.31

10.4

10.9

0.108

0.108

6

0.30

3.30

4.01

4.21

6.95

7.29

0.104

0.104

10

0.40

1.91

2.41

2.52

4.17

4.38

0.0982

0.102

16

0.40

1.21

1.47

1.54

2.55

2.68

0.0937

0.0970

25

0.40

0.780

0.889

0.932

1.55

1.62

0.0895

0.0921

35

0.40

0.554

0.652

0.684

1.14

1.19

-

0.0895

50

0.40

0.386

0.490

0.513

0.862

0.902

-

0.0893

70

0.50

0.272

0.325

0.340

0.581

0.608

-

0.0859

87


Addison Industrial Cables Australian Standard CURRENT RATING Nom. conductor area

2 core a nd Earth Protected from sun

Exposed to sun

3 core and earth,

4 core and earth

Protected from sun

Exposed to sun

V75

XLPE

V75

XLPE

V75

XLPE

V75

XLPE

mm²

A

A

A

A

A

A

A

A

6

44

54

34

43

38

46

29

37

10

60

74

46

58

52

63

39

50

16

81

99

60

77

70

85

51

66

25

110

135

80

105

95

115

68

88

35

135

165

95

125

115

140

81

105

50

160

195

110

145

140

165

96

125

70

205

250

140

185

175

215

120

155

Cable Parameter TYPE 1 Nom. conductor area mm²

Core diameter mm

Earth conductor area mm²

Earth core diameter mm

Over bedding diameter mm

Cable diameter mm

Approx. mass kg/km

1.5

3.2

1.5

3.2

9.8

14.48

220

2C+E

2.5

3.7

2.5

3.7

11.0

15.85

272

3C+E

1.0

2.9

1.0

2.7

9.1

13.62

205

3C+E

1.5

3.2

1.5

3.0

9.8

14.48

238

3C+E

2.5

3.7

2.5

3.5

11.0

15.85

299

3C+E

4

4.7

4

4.7

13.3

18.58

417

3C+3E

6

5.3

1.5

3.0

13.4

16.86

478

3C+3E

10

6.2

1.5

3.0

15.5

19.07

636

3C+3E

16

7.4

2.5

3.5

18.4

22.10

908

3C+3E

25

9.1

4

4.7

22.3

29.12

1357

3C+3E

35

10.3

6

5.3

25.3

32.71

1794

3C+3E

50

12.3

10

6.2

29.5

37.67

2480

3C+3E

70

14.0

10

6.2

33.5

42.75

3323

4C+E

1.5

3.2

1.5

3.0

9.2

13.79

239

4C+E

2.5

3.7

2.5

3.5

10.5

15.21

309

4C+E

4

4.7

2.5

3.5

12.4

17.49

415

4C+E

6

5.3

2.5

3.5

13.6

18.92

516

No. of Core

2C+E

88


Caledonian Industrial Cables Australian Standard Nom. conductor area mm²

Core diameter mm

Earth conductor area mm²

Earth core diameter mm

Over bedding diameter mm

Cable diameter mm

Approx. mass kg/km

10

6.2

4

4.7

16.1

21.87

753

4C+E

16

7.4

6

5.3

18.7

24.89

1054

4C+E

25

9.1

6

5.3

22.2

29.03

1499

4C+E

35

10.3

10

6.2

25.2

32.51

1987

4C+E

50

12.3

16

7.4

29.6

37.80

2766

4C+E

70

14.0

25

9.1

34.0

43.37

3877

Nom. conductor area mm²

Core diameter mm

Earth core diameter mm

Approx. mass kg/km

3.2

1.5

3.0

Over bedding diameter mm

Cable diameter mm

1.5

Earth conductor area mm²

8.8

12.26

201

3C+E

2.5

3.7

2.5

3.5

10.1

13.56

260

3C+3E

4

4.7

1.5

3.0

10.4

13.89

311

3C+3E

6

5.3

1.5

3.0

11.7

15.34

393

3C+3E

10

6.2

1.5

3.0

13.9

17.64

563

3C+3E

16

7.4

2.5

3.5

16.4

20.34

808

3C+3E

25

9.1

4

4.1

20.3

24.53

1206

3C+3E

35

10.3

6

4.7

23.1

27.49

1608

3C+3E

50

12.3

10

5.6

27.0

31.70

2248

3C+3E

70

14.0

10

5.6

31.4

36.84

3118

4C+E

1.5

3.2

1.5

3.0

9.4

12.65

222

4C+E

2.5

3.7

2.5

3.5

10.5

13.89

288

4C+E

4

4.7

2.5

3.5

11.6

15.05

362

4C+E

6

5.3

2.5

3.5

12.8

16.30

455

4C+E

10

6.2

4

4.7

15.2

18.88

676

4C+E

16

7.4

6

5.3

18.0

21.95

980

4C+E

25

9.1

6

5.3

21.6

25.78

1405

4C+E

35

10.3

10

6.2

24.9

29.25

1900

4C+E

50

12.3

16

7.4

28.8

33.46

2618

4C+E

70

14.0

25

9.1

33.6

38.97

3740

No. of Core

4C+E

TYPE 2 No. of Core

3C+E

89


Addison Industrial Cables Australian Standard VSD/EMC Cables (Copper Tape Screened), 0.6/1kV Application These cables are used to supply motors from variable speed controls unenclosed, enclosed in conduit, mounted on tray, or in underground ducts for industrial plants, where not subject to mechanical damage. They are designed to significantly reduce radiated interference from electrical noise by using symmetrical, balanced and screened construction.

Standard AS/NZS 5000.1, AS 1125, AS 3808

Cable Construction Copper tape screen Non-hygroscopic material laying up Earth conductor XLPE insulation Plain annealed copper conductor PVC bedding PVC outer sheath

Conductor: Plain annealed copper, class 2 strands Insulation: XLPE, X-90 Insulation colour: Red, White, Blue & Green/Yellow Laying up: Non-hygroscopic material(optional) Bedding: Flame retardant polyvinyl chloride PVC V90 Screen: Plain annealed copper tape with 100% coverage Sheath: Flame retardant polyvinyl chloride PVC V90 Sheath colour: Black

90


Caledonian Industrial Cables Australian Standard Technical Characteristics Conductor Nominal Area mm2

2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

Current Ratings Unenclosed Unenclosed Touching In Air A A

29 39 50 68 91 121 149 187 237 292 336 385 446 528 605

Buried In Ducts A

24 32 42 58 77 108 127 154 193 231 275 308 358 424 -

32 41 51 68 89 118 144 171 214 257 294 332 380 449 508

Core diameter mm

Earth conductor area mm²

Electrical Characteristics Maximum Maximum AC DC Three Phase Resistance Reactance Resistance Voltage Drop @90°C Ohm/km @20°C mV/Am Ohm/km Ohm/km

7.41 4.61 3.08 1.83 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641

9.45 5.88 3.93 2.33 1.54 0.932 0.684 0.513 0.340 0.266 0.206 0.162 0.134 0.105 0.0836

0.0988 0.0930 0.0887 0.0840 0.0805 0.0808 0.0786 0.0751 0.0741 0.0725 0.0713 0.0718 0.0720 0.0709 0.0704

16.4 10.2 6.80 4.05 2.68 1.62 1.19 0.902 0.608 0.485 0.387 0.317 0.275 0.233 0.205

Earth core diameter mm

Over bedding diameter mm

Cable diameter mm

Approx. mass kg/km

15.0 15.3 16.9 17.8 21.0 24.4 27.2 30.8 35.7 39.9 43.8 48.4 54.1 60.2 66.3

330 375 415 550 760 1130 1480 2110 2740 3590 4400 5450 6760 8600 10640

Cable Parameter No. of Core

3C+E 3C+E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E 3C+3E

Nom. conductor area mm²

2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

3.7 4.7 5.3 6.2 7.4 9.1 10.3 12.3 14.0 15.3 17.1 19.2 21.5 24.2 26.8

2.5 4 1.5 1.5 2.5 4 6 10 10 16 16 25 25 35 50

3.5 4.7 3.0 3.0 3.5 4.7 5.3 6.2 6.2 7.4 7.4 9.1 9.1 10.3 12.3

10.9 13 13.8 14.8 17 19.2 21.9 25.1 28.1 33.9 38.9 42.6 47.5 53.6 59.6

91


Addison Industrial Cables Australian Standard

92


Caledonian Industrial Cables Australian Standard