Caledonian Windmill Cables

>> Power Cables >> Control Cables >> Data Cables >> Communica�on Cables >> Fiber Op�c Cables

www.addison-cables.com


Caledonian Windmill Cables

COMPANY PROFILE Table of Content

Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison, produces a wide range of cables for communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.


TABLE OF CONTENT

»» Power Cable LSOH Torsion Resistant Power Cable 0.6/1kV ��������������������������������������������������������������������������������1 LSOH Screened Torsion Resistant Loop Cable 0.6/1kV ������������������������������������������������������������������3 AL Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90°C ����������������������������������������������������������5 AL Conductor HEPR/PO 0.6/1kV LSOH Power Cable 90°C �������������������������������������������������������������7 H07BN4-F 450/750V Torsion Resistant Cable ��������������������������������������������������������������������������������9 H07BN4-F & UL/CSA 600V 90°C Torsion Resistant Cable ������������������������������������������������������������12 H07BN4-F & UL/CSA 1000V 90°C Torsion Resistant Cable ����������������������������������������������������������14 H07ZZ-F 450/750V Torsion Resistant Cable ���������������������������������������������������������������������������������16 H07ZZ-F & UL/CSA 600V EPR/XLEVA Torsion Resistant Cable ������������������������������������������������������19 H07ZZ-F & UL/CSA 1000V EPR/XLEVA Torsion Resistant Cable ����������������������������������������������������21 PVC/PVC to UL/CSA 600V Torsion Resistant Cable �����������������������������������������������������������������������23 UL/CSA 600V PVC/PVC Screened Torsion Resistant Cable �����������������������������������������������������������26 UL/CSA 1000V PVC/PVC Torsion Resistant Cable 90°C ����������������������������������������������������������������29 UL/CSA 1000V PVC/PVC Screened Torsion Resistant Cable 90°C �������������������������������������������������33 DLO 2kV Torsion Resistant Cable to UL 44 �����������������������������������������������������������������������������������36 NYY 0.6/1kV Power Cable ������������������������������������������������������������������������������������������������������������38 NAYY 0.6/1kV Power/Control Cable ���������������������������������������������������������������������������������������������42 N2XY 0.6/1kV Power Cable ����������������������������������������������������������������������������������������������������������44 N2XH 0.6/1kV LSOH Power Cable ������������������������������������������������������������������������������������������������46 NA2XH 0.6/1kV LSOH Power Cable ����������������������������������������������������������������������������������������������47 H05BQ-F/H07BQ-F ����������������������������������������������������������������������������������������������������������������������49


Caledonian Windmill Cables

Table of Content H05V-K/H07V-K Internal Wiring Cable �����������������������������������������������������������������������������������������51 S-3GSHXOEU HFFR 0.6/1kV & UL 1000V 90°C �����������������������������������������������������������������������������53 S-3GSHCOEU 0.6/1kV & UL 1000V 90°C ��������������������������������������������������������������������������������������55 Halogen Free Torsion Resistant Fire Alarm Cable 24V �����������������������������������������������������������������56 High Temperature Resistant Cables +145°C 0.6/1kV �������������������������������������������������������������������57 EPR/HFXLEVA Medium Voltage Torsion Resistant Cable ��������������������������������������������������������������59 NTSCGEWOEU Medium Voltage Torsion Resistant Cable 3.6/6kV �����������������������������������������������61 N2XS2Y Medium Voltage Power Cable ����������������������������������������������������������������������������������������62 NA2XS(F)2Y RE/RM Medium Voltage Power Cable ����������������������������������������������������������������������65 NTSCGEWOEU Medium Voltage Torsion Resistant Cable 12~35kV ���������������������������������������������68 (N)TSCGEHXOEU Medium Voltage LSOH Torsion Resistant Cable �����������������������������������������������70 Medium Voltage High Temperature Resistant Cables +180°C �����������������������������������������������������72

»» Control Cable H07RN-F 450/750V ����������������������������������������������������������������������������������������������������������������������75 H07RN-F & UL/CSA 600V 90°C �����������������������������������������������������������������������������������������������������78 (H)07RN-F HFFR & UL/CSA 600V 90°C �����������������������������������������������������������������������������������������80 H05VV5-F 300/500V ��������������������������������������������������������������������������������������������������������������������82 H05VVC4V5-K 300/500V ��������������������������������������������������������������������������������������������������������������84 Halogen Free Grounding Cable 0.6/1kV ��������������������������������������������������������������������������������������86 Y 300/500V ���������������������������������������������������������������������������������������������������������������������������������88 CY 300/500V ��������������������������������������������������������������������������������������������������������������������������������93 YCY 300/500V ������������������������������������������������������������������������������������������������������������������������������96 Halogen Free Control Cable 300/500V ����������������������������������������������������������������������������������������99 Halogen Free, Screened Control Cable 300/500V ���������������������������������������������������������������������104


Caledonian Windmill Cables

Table of Content Y 0.6/1kV �����������������������������������������������������������������������������������������������������������������������������������108 YCY 0.6/1kV ��������������������������������������������������������������������������������������������������������������������������������114 Halogen Free Control Cable 0.6/1 kV �����������������������������������������������������������������������������������������117 Halogen Free, Screened Control Cable 0.6/1 kV ������������������������������������������������������������������������120 Halogen Free, Screened Control Cable 0.6/1 kV 90°C ���������������������������������������������������������������123 Y 0.6/1kV UL/CSA �����������������������������������������������������������������������������������������������������������������������125 YCY 0.6/1kV UL/CSA �������������������������������������������������������������������������������������������������������������������128 Y UL/CSA 600V 90°C �������������������������������������������������������������������������������������������������������������������131 YCY UL/CSA 600V 90°C ���������������������������������������������������������������������������������������������������������������134 Wind Turbine Tray cable (WTTC) ������������������������������������������������������������������������������������������������137

»» Data Cable LiYCY Data Cable �����������������������������������������������������������������������������������������������������������������������141 LiYCY Twisted Pair Data Cable ���������������������������������������������������������������������������������������������������146 LiHH Multicore Halogen-free Data Cable ����������������������������������������������������������������������������������150 LiHCH Multicore Halogen-free Data Cable ��������������������������������������������������������������������������������153 LiHCH Twisted Pair Halogen-free Data Cable ����������������������������������������������������������������������������156 LiYY Data Cable UL ���������������������������������������������������������������������������������������������������������������������159 LiYCY Data Cable UL �������������������������������������������������������������������������������������������������������������������162 LiYY Twisted Pair Data Cable UL �������������������������������������������������������������������������������������������������165 LiYCY Twisted Pair Data Cable UL �����������������������������������������������������������������������������������������������168 PUR Sheathed, Halogen Free Data Cable ����������������������������������������������������������������������������������171 PUR Sheathed, Screened, Halogen Free Data Cable �����������������������������������������������������������������173 PUR Sheathed, Screened, Halogen Free, Twisted Pair Data Cable ��������������������������������������������175


Caledonian Windmill Cables

Table of Content »» Communication Cable PUR Sheathed, Halogen Free CAN BUS 2×2×0.22mm² ��������������������������������������������������������������178 PUR Sheathed CAN BUS 2×2×0.25mm² �������������������������������������������������������������������������������������180 Indoor/Outdoor PROFIBUS ��������������������������������������������������������������������������������������������������������181 PUR Sheathed, Halogen Free PROFIBUS ������������������������������������������������������������������������������������183 PROFInet AWG 22/1 ������������������������������������������������������������������������������������������������������������������185 PROFInet AWG 22/7 ������������������������������������������������������������������������������������������������������������������187 PROFInet AWG 22/19 ����������������������������������������������������������������������������������������������������������������189 PUR Sheathed, Halogen Free S-FTP Cat5 �����������������������������������������������������������������������������������191

»» Fibre Optic Cable A-V(ZN)11Y Fibre Optic Cable ����������������������������������������������������������������������������������������������������193 I-V(ZN)Y11Y Fibre Optic Breakout Cable ������������������������������������������������������������������������������������194 I-V(ZN)H11Y Fibre Optic Breakout Cable �����������������������������������������������������������������������������������195 I-V(ZN)YY Fibre Optic Breakout Cable ����������������������������������������������������������������������������������������196 I-V(ZN)HH Fibre Optic Breakout Cable ���������������������������������������������������������������������������������������197 I-V2Y POF Cord ���������������������������������������������������������������������������������������������������������������������������199 I-V2Y(ZN)11Y/I-V2Y(ZN)2Y POF Breakout Cable �������������������������������������������������������������������������200 A-DQ(ZN)BH/I-DQ(ZN)BH Fibre Optic Cables �����������������������������������������������������������������������������201 A-DQ(ZN)B2Y Fibre Optic Cables ������������������������������������������������������������������������������������������������203 QFCI �������������������������������������������������������������������������������������������������������������������������������������������204


Caledonian Windmill Cables

Power Cable LSOH Torsion Resistant Power Cable 0.6/1kV »» Application These cables with increased tolerance to torsion application, UV and ozone resistant, good bending and halogen free are specifically designed for the torsion applications in wind turbines, suitable for transmit energy from the generator to the transformer.

»» Standards IEC 60502

»» Construction

Stranded Copper Conductor EPR/HFXLPE Insulation HFXLEVA Sheath

Conductor: Stranded tinned copper, class 5/class 6 according to IEC 60228. Insulation: EPR/HFXLPE. Sheath: HFXLEVA.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Ozone Resistant

0.6/1kV -40℃~+90℃ 6×OD +/-144°/m IEC 60332-3 IEC 60754 IEC 60754 IEC 61034 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

1


Caledonian Windmill Cables

Power Cable UV Resistant Cold Resistant

Yes CSA C 22.2

»» Dimensions and Weight

2

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

3×25 3×35 3×50 3×70 3×95 3×120 4×25 4×35 4×50 4×70 4×95 4×120

27.5 31.0 36.0 40.5 46.5 50.5 30.5 34.5 39.0 43.5 51.5 56.0

1500 1960 2640 3150 4575 5490 1870 2320 3100 4240 5716 6950

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable LSOH Screened Torsion Resistant Loop Cable 0.6/1kV »» Application These cables are designed for special application condition in wind turbines, special for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.

»» Standards IEC 60502 EN 50363 HD 22.13

»» Construction Stranded Copper Conductor Halogen Free Insulation Tinned Copper Braid Halogen Free EVA Sheath

Conductor: Stranded bare copper conductor. Insulation: Extruded halogen free rubber compound EI8. Screen: Tinned wire copper braid. Sheath: Extruded halogen free EVA compound EM8.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radii Torsion Application Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Halogen Free Smoke Density

0.6/1 kV flexing: -35℃~+90℃; fixed: -40℃~+90℃ flexing: 6×OD; fixed: 4×OD ± 100 °/m 15 N/mm² (in operation) 250℃ EN 50265-2-1 IEC 60754 IEC 61034

www.caledonian-cables.co.uk www.addison-cables.com

3


Caledonian Windmill Cables

Power Cable Oil Resistant Ozone Resistant Silicone Free

Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 25×0.75 25×1 4×1.5 12×1.5 32×1.5 42×1.5 12×2.5 5×2.5 4×4

4

Nominal Overall Diameter mm 18.0 20.0 10.0 16.0 26.0 35.0 23.0 15.0 13.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 500 550 150 400 950 1700 620 300 300


Caledonian Windmill Cables

Power Cable AL Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90°C »» Application These durable, high temperature resistant LSOH cables are designed for wind turbines and dedicated for fixed installation inside the tower.

»» Standards IEC 60502-1

»» Construction Aluminium Conductor XLEPR Insulation XLEVA Sheath

Conductor: Aluminium conductor, class 2 according to IEC 60228/EN 60228. Insulation: Special cross-linked halogen free rubber EPR for high temperatures. Sheath: Special cross-linked synthetic halogen free rubber EM8 (XLEVA). CPE can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radii Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Ozone Resistant

0.6/1kV -40℃~+ 90℃ 6×OD 15N/mm² 250℃ IEC 60332-1/ IEC 60332-3 IEC 60754 IEC 60754 IEC 61034 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

5


Caledonian Windmill Cables

Power Cable UV Resistant Water Resistant

Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×150 1×185 1×240 1×300 1×400

6

Nominal Overall Diameter mm 22.5 25.0 27.8 30.5 35.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 640 770 980 1210 1550


Caledonian Windmill Cables

Power Cable AL Conductor HEPR/PO 0.6/1kV LSOH Power Cable 90°C »» Application These cables are designed for main power lines of permanent routing in wind tower installation.

»» Standards IEC 60502

»» Construction Stranded Aluminium Conductor HEPR/XLPE Insulation Polyolefin Sheath

Conductor: Aluminium conductor, class 2 to IEC 60228. Insulation: HEPR. XLPE can be offered upon request. Inner Covering: rubber compound type GM1b. Sheath: Compound based on polyolefin, type HXM1.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Flame Retardant Halogen Free Gases Corrosively Smoke Density Oil Resistant Ozone Resistant UV Resistant

0.6/1kV -40℃~+ 90℃ 4×OD 250℃ IEC 60332-1 IEC 60754 DIN EN 50267-2/ IEC 60754 IEC 61034 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

7


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 3×150 4×150

8

Nominal Overall Diameter mm 13.0 15.0 16.5 18.0 20.0 22.5 26.0 29.0 32.5 44.0 49.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 266 352 450 556 686 842 1076 1299 1680 2756 3367


Caledonian Windmill Cables

Power Cable H07BN4-F 450/750V Torsion Resistant Cable »» Application These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines and to be used for the loop.

»» Standards DIN VDE 0282.12 HD 22.12

»» Construction Stranded Copper Conductor EPR Insulation CM/CR Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/HD 383/ IEC 60228. Insulation: Cold and heat resistant EPR. Special cross-linked EI7 rubber for high temperatures can be offered upon request. Sheath: Ozone, UV-resistant, oil and cold-resistant special compound based on CM (chlorinated polyethylene)/CR (chloroprene rubber). Special cross-linked EM7 rubber can be offered upon request.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Maximum Permissible Tensile Load Torsion Application Short-circuit Temperature Flame Retardant Oil Resistant

450/750V -40℃~+90℃ 6×OD 15 N/mm² +/-150°/m 250℃ EN 50265-1/EN 50265-2-1/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com

9


Caledonian Windmill Cables

Power Cable Ozone Resistant UV Resistant

Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×25 1×35 1×50 1×70 1×95 1×(G)10 1×(G)16 1×(G)25 1×(G)35 1×(G)50 1×(G)70 1×(G)120 1×(G)150 1×(G)185 1×(G)240 1×300 1×400 10G1.5 12G1.5 12G2.5 18G1.5 18G2.5 2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 24G1.5 24G2.5 3×25 3×35 3×50 3×70

10

Nominal Overall Diameter mm 13.5 15.0 17.3 19.3 22.7 28.6 28.6 28.6 28.6 17.9 28.6 24.7 27.1 29.5 32.8 36.0 40.2 19.0 19.3 22.6 22.6 26.5 28.6 28.6 12.9 14.1 19.4 21.9 26.2 26.4 31.4 28.6 32.2 37.3 43.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 371 482 667 888 1160 175 245 365 470 662 880 1430 1740 2160 2730 3480 4510 470 500 670 725 980 110 160 235 275 530 730 1060 980 1390 1345 1760 2390 3110


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 3×95 3×(G)1.5 3×(G)2.5 3×(G)4 3×(G)6 3×(G)10 3×(G)16 3×120 3×150 4G1.5 4G2.5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 5G1.5 5G2.5 5G4 5G6 5G10 5G16 5G25 5G35 5G50 5G70 5G95 6G1.5 6G2.5 7G1.5 7G2.5 8×1.5

Nominal Overall Diameter mm 47.2 10.1 12.0 13.9 15.6 21.1 23.9 51.7 57.0 11.2 13.6 15.5 17.1 23.5 25.9 31.0 35.3 40.5 46.4 52.2 56.5 12.2 14.7 17.1 19.0 25.0 28.7 35.0 38.4 43.9 50.5 57.8 14.7 16.9 16.5 18.5 17.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 4170 130 195 285 340 650 910 5060 6190 160 240 350 440 810 1150 1700 2170 3030 3990 5360 6480 230 295 430 540 1020 1350 2080 2650 3750 4950 6700 295 390 350 460 400

11


Caledonian Windmill Cables

Power Cable H07BN4-F & UL/CSA 600V 90°C Torsion Resistant Cable »» Application These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.

»» Standards HD 22.12 UL/CSA 22.2 UL 758

»» Construction Stranded Copper Conductor EPR/EPDM Insulation CPE Sheath

Conductor: Flexible annealed bare copper, class 5 according to IEC/EN 60228. Insulation: Special cross-linked EI7 rubber for high temperatures (EPDM class 28). Special thermoset EPR for high temperature can be offered upon request. Sheath: High mechanical performance special cross-linked EM7 rubber (CPE class 42). Special thermoset CPE improved for low temperature behaviour (-40°C) can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Oil Resistant 12

600V -40℃~+90℃ flexing: 6×OD; fixed: 4×OD +/-150°/m 15 N/mm² 250℃ EN 50265-1/EN 50265-2-1/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Ozone Resistant UV Resistant Water Resistant Impact Resistant

Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×120(4/0AWG) 1×150(250MCM) 1×185(350MCM) 1×240(450MCM) 1×300(550MCM) 1×400(750MCM) 1×50(1 AWG) 1×95(3/0 AWG) 3×120(4/0 AWG) 3×150(250MCM) 3×240(450MCM) 3×25(4 AWG) 3×35(2 AWG) 3×50(1 AWG) 3×70(2/0 AWG) 3×95(3/0 AWG) 4G50(1 AWG) 4G70(2/0 AWG) 4G95(3/0 AWG) G: with green-yellow earth core

Nominal Overall Diameter mm 25.5 28.8 31.4 33.8 37.7 41.4 18.7 23.0 56.0 61.5 72.0 30.0 35.3 39.8 43.8 49.0 42.5 48.2 53.5

Nominal Weight kg/km 1540 1810 2210 2750 3520 4510 730 1220 5200 6400 9780 1420 1850 2480 3180 4260 3150 4240 5480

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

13


Caledonian Windmill Cables

Power Cable H07BN4-F & UL/CSA 1000V 90°C Torsion Resistant Cable »» Application These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.

»» Standards HD 22.12 UL/CSA 22.2 UL 758

»» Construction Stranded Copper Conductor EPR/EPDM Insulation CPE Sheath

Conductor: Flexible annealed bare copper, class 5 according to IEC/EN 60228. Insulation: Special cross-linked EI7 rubber for high temperatures (EPDM class 28). Special thermoset EPR for high temperature can be offered upon request. Sheath: High mechanical performance special cross-linked EM7 rubber (CPE class 42). Special thermoset CPE improved for low temperature behaviour (-40°C) can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Oil Resistant 14

1000V -40℃~+90℃ flexing: 6×OD; fixed: 4×OD +/-150°/m 15 N/mm² 250℃ EN 50265-1/EN 50265-2-1/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Ozone Resistant UV Resistant Water Resistant Impact Resistant

Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×120(4/0 AWG) 1×150(250MCM) 1×185(350MCM) 1×240(450MCM) 1×300(550MCM) 1×400(750MCM) 1×50(1 AWG) 1×95(3/0 AWG) 3×120(4/0 AWG) 3×150(250MCM) 3×240(450MCM) 3×25(4 AWG) 3×35(2 AWG) 3×50(1 AWG) 3×70(2/0 AWG) 3×95(3/0 AWG) 4G50(1 AWG) 4G70(2/0 AWG) 4G95(3/0 AWG) G: with green-yellow earth core

Nominal Overall Diameter mm 25.5 28.8 31.4 33.8 37.7 41.4 18.7 23.0 56.0 61.5 72.0 30.0 35.3 39.8 43.8 49.0 42.5 48.2 53.5

Nominal Weight kg/km 1540 1810 2210 2750 3520 4510 730 1220 5200 6400 9780 1420 1850 2480 3180 4260 3150 4240 5480

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

15


Caledonian Windmill Cables

Power Cable H07ZZ-F 450/750V Torsion Resistant Cable »» Application These cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines and to be used for the loop.

»» Standards HD 22-13

»» Construction Stranded Copper Conductor EPDM Insulation CPE Sheath

Conductor: Stranded bare copper, fine wire class 5 according to DIN VDE 0295/HD 383/ IEC 60228. Insulation: Special cross-linked EPDM rubber (type EI7) for high temperatures. Sheath: Special cross-linked CPE (type EM7).

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Maximum Permissible Tensile Load Minimum Bending Radius Torsion Application Short-circuit Temperature Flame Retardant Smoke Density Oil Resistant Ozone Resistant 16

450/750V -40℃~+90℃ 15 N/mm² flexing: 6×OD; fixed: 4×OD +/-150°/m 250℃ EN 50265-1/EN 50265-2-1/IEC 60332-1/IEC 60332-3 LSF EN 61034 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable UV Resistant Water Resistant Impact Resistant

Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×(G)10 1×(G)16 1×(G)25 1×(G)35 1×(G)70 1×(G)120 1×(G)150 1×(G)185 1×(G)240 1×50 1×95 1×300 1×400 2×1.5 2×10 2×16 2×2.5 2×4 2×6 2×25 3×25 3×35 3×50 3×70 3×95 3×(G)1.5 3×(G)2.5 3×(G)4 3×(G)6 3×(G)10 3×(G)16 3×120 3×150 4G1.5

Nominal Overall Diameter mm 10.3 11.7 13.9 15.7 20.3 24.7 27.1 29.5 32.8 17.9 22.7 36.0 40.2 9.4 19.4 21.9 11.2 12.9 14.1 26.2 28.6 32.2 37.3 43.0 47.2 10.1 12.0 13.9 15.6 21.1 23.9 51.7 57.0 11.2

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 175 245 365 470 880 1430 1740 2160 2730 662 1160 3480 4510 110 530 730 160 235 275 1060 1345 1760 2390 3110 4170 130 195 285 340 650 910 5060 6190 160

17


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 4G2.5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 5G1.5 5G2.5 5G4 5G6 5G10 5G16 5G25 5G35 5G50 5G70 5G95 6G1.5 6G2.5 7G1.5 7G2.5 8×1.5 10G1.5 12G1.5 12G2.5 18G1.5 18G2.5 24G1.5 24G2.5 G: with green-yellow earth core

Nominal Overall Diameter mm 13.6 15.5 17.1 23.5 25.9 31.0 35.3 40.5 46.4 52.2 56.5 12.2 14.7 17.1 19.0 25.0 28.7 35.0 38.4 43.9 50.5 57.8 14.7 16.9 16.5 18.5 17.0 19.0 19.3 22.6 22.6 26.5 26.4 31.4

×: without green-yellow earth core

18

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 240 350 440 810 1150 1700 2170 3030 3990 5360 6480 230 295 430 540 1020 1350 2080 2650 3750 4950 6700 295 390 350 460 400 470 500 670 725 980 980 1390


Caledonian Windmill Cables

Power Cable H07ZZ-F & UL/CSA 600V EPR/XLEVA Torsion Resistant Cable »» Application These halogen free cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.

»» Standards UL/CSA 22.2 UL 758 HD 22.13

»» Construction Stranded Copper Conductor EPR/EPDM Insulation Halogen Free XLEVA/XLCPE Sheath

Conductor: Stranded annealed bare copper, class 5 according to DIN VDE 0295/HD 383/IEC 60228. Insulation: Special thermoset EPR for high temperature. Special cross-linked improved for EI8 and EI7 base on EPDM can be offered upon request. Sheath: Special halogen free thermoset XLEVA. High mechanical performance special crosslinked EM8 synthetic halogen free rubber based on CPE can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Maximum Permissible Tensile Load Minimum Bending Radius Torsion Application Short-circuit Temperature

CENELEC 450/750V; UL/CSA 600V -40℃~+90℃ 15 N/mm² flexing: 6×OD; fixed: 4×OD +/-150°/m 250℃

www.caledonian-cables.co.uk www.addison-cables.com

19


Caledonian Windmill Cables

Power Cable Flame Retardant Halogen Free Smoke Density Oil Resistant Ozone Resistant UV Resistant Water Resistant Impact Resistant

IEC 60332-1/IEC 60332-3 IEC 60754 LSF EN 61034/IEC 61034 Yes Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 3×120 3×150 3×240 3×25 3×35 3×50 3×70 3×95 3×120 4G25 4G35 4G50 4G70 4G95 4G120 G: with green-yellow earth core

Nominal Overall Diameter mm 13.5 15.0 18.7 19.3 23.0 25.5 28.8 31.4 33.8 37.7 41.4 56.0 61.5 72.0 30.0 35.3 39.8 43.8 49.0 52.8 32.8 36.3 42.5 48.2 53.5 58.3

×: without green-yellow earth core

20

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 371 482 730 888 1220 1540 1810 2210 2750 3520 4510 5200 6400 9780 1420 1850 2480 3180 4260 5490 1870 2320 3150 4240 5480 6950


Caledonian Windmill Cables

Power Cable H07ZZ-F & UL/CSA 1000V EPR/XLEVA Torsion Resistant Cable »» Application These halogen free cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.

»» Standards UL/CSA 22.2 UL 758 HD 22.13

»» Construction Stranded Copper Conductor EPR/EPDM Insulation Halogen Free XLEVA/XLCPE Sheath

Conductor: Stranded annealed bare copper, class 5 according to DIN VDE 0295/HD 383/IEC 60228. Insulation: Special thermoset EPR for high temperature. Special cross-linked improved for EI8 and EI7 EPDM can be offered upon request. Sheath: Special halogen free thermoset XLEVA. High mechanical performance special crosslinked EM8 synthetic halogen free rubber based on CPE can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Maximum Permissible Tensile Load Minimum Bending Radius Torsion Application Short-circuit Temperature

CENELEC 450/750V; UL/CSA 1000V -40℃~+90℃ 15 N/mm² flexing: 6×OD; fixed: 4×OD +/-150°/m 250℃

www.caledonian-cables.co.uk www.addison-cables.com

21


Caledonian Windmill Cables

Power Cable Flame Retardant Halogen Free Smoke Density Oil Resistant Ozone Resistant UV Resistant Water Resistant Impact Resistant

IEC 60332-1/IEC 60332-3 IEC 60754 LSF EN 61034/IEC 61034 Yes Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 3×120 3×150 3×240 3×25 3×35 3×50 3×70 3×95 3×120 4G25 4G35 4G50 4G70 4G95 4G120 G: with green-yellow earth core

Nominal Overall Diameter mm 13.5 15.0 18.7 19.3 23.0 25.5 28.8 31.4 33.8 37.7 41.4 56.0 61.5 72.0 30.0 35.3 39.8 43.8 49.0 52.8 32.8 36.3 42.5 48.2 53.5 58.3

×: without green-yellow earth core

22

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 371 482 730 888 1220 1540 1810 2210 2750 3520 4510 5200 6400 9780 1420 1850 2480 3180 4260 5490 1870 2320 3150 4240 5480 6950


Caledonian Windmill Cables

Power Cable PVC/PVC to UL/CSA 600V Torsion Resistant Cable »» Application These cables with increased tolerance to Torsion Application, UV and oil resistant are specifically designed for the torsion applications in wind turbines.

»» Standards UL 758

»» Construction Stranded Copper Conductor Special PVC Insulation Special PVC Sheath

Conductor: Stranded bare copper according to DIN VDE 0295. Insulation: Special PVC flexible at low temperatures. Sheath: Special PVC flexible at low temperatures.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant UV Resistant

600V flexing: -40℃~+80℃; fixed: -40℃~+80℃ flexing:10×OD; fixed: 4×OD +/-140°/m CSA C 22.2 IEC 60811-2-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com

23


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 4×0.34 4×0.5 6×0.5 10×0.5 12×0.5 3×0.75 4×0.75 5×0.75 7×0.75 10×0.75 12×0.75 14×0.75 16×0.75 18×0.75 21×0.75 25×0.75 32×0.75 36×0.75 40×0.75 41×0.75 50×0.75 4×1 5×1 7×1 10×1 12×1 14×1 16×1 18×1 21×1 25×1 32×1 36×1 40×1 41×1 50×1 2×1.5 3×1.5 4×1.5 5×1.5 7×1.5 10×1.5 24

AWG /MCM 22 20 20 20 20 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 16 16 16 16 16 16

Nominal Overall Diameter mm 7.1 7.4 8.6 10.8 11.1 7.3 7.9 8.6 10.0 11.0 11.8 12.5 13.2 13.9 15.2 16.9 18.2 19.1 20.5 20.8 23.5 8.3 9.0 10.5 13.0 13.2 13.4 14.1 15.1 16.7 18.4 19.8 20.6 22.4 22.4 24.6 7.9 8.0 8.9 9.7 12.0 13.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 86 99 121 165 208 77 100 120 170 200 220 238 271 310 380 490 560 620 729 729 990 100 110 140 220 240 280 310 360 410 500 590 700 800 810 980 75 110 131 165 210 270


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 12×1.5 14×1.5 16×1.5 18×1.5 21×1.5 25×1.5 32×1.5 36×1.5 40×1.5 41×1.5 50×1.5 3×2.5 4×2.5 5×2.5 7×2.5 10×2.5 12×2.5 19×2.5 3×4 4×4 5×4 7×4 12×4 3×6 4×6 5×6 7×6 4×10 5×10 7×10 4×16 5×16 4×25 5×25 4×35 5×35 4×50 1×35 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400

AWG /MCM 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 12 12 12 12 12 10 10 10 10 8 8 8 6 6 4 4 2 2 1 2 2/0 3/0 4/0 300 350 500 600 750

Nominal Overall Diameter mm 14.3 14.9 15.7 16.8 17.8 20.6 22.2 23.1 25.0 25.0 27.7 8.9 9.7 10.9 14.4 15.8 16.3 20.4 10.8 12.0 13.6 15.9 19.6 13.1 14.6 16.3 19.6 17.4 20.1 23.5 22.6 25.4 26.5 28.2 31.4 35.4 36.7 12.9 17.9 21.9 23.1 27.2 28.0 31.2 35.0 39.3

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 360 420 450 510 590 700 900 980 1030 1050 1200 151 230 250 360 480 580 690 250 270 370 530 740 340 460 550 780 670 870 1150 1000 1250 1580 1900 2100 2600 2800 460 880 1230 1540 1870 2300 2970 3730 4500 25


Caledonian Windmill Cables

Power Cable UL/CSA 600V PVC/PVC Screened Torsion Resistant Cable »» Application These cables with increased tolerance to torsion application, UV and oil resistant are specifically designed for wind power applications.

»» Standards UL 758

»» Construction Stranded Copper Conductor Special PVC Insulation Tinned Copper Wire Screen Special PVC Sheath

Conductor: Stranded bare copper according to DIN VDE 0295. Insulation: Special PVC flexible at low temperatures. Screen: Tinned copper wire wrapped. Sheath: Special PVC flexible at low temperatures.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant UV Resistant

26

1000V -40℃~+80℃ 10×OD +/-90°/m FT1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 2×2×0.25 4×2×0.25 5×2×0.25 4×0.34 2×2×0.34 4×2×0.34 4×0.5 6×0.5 10×0.5 12×0.5 2×2×0.5 4×2×0.5 3×0.75 4×0.75 5×0.75 7×0.75 8×0.75 12×0.75 18×0.75 25×0.75 32×0.75 41×0.75 50×0.75 2×2×0.75 4×2×0.75 8×2×0.75 12×2×0.75 4×1.0 6×1.0 8×1.0 12×1.0 2×1.5 3×1.5 4×1.5 5×1.5 7×1.5 12×1.5 2×2×1.5

AWG /MCM 24 24 24 22 22 22 20 20 20 20 20 20 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 18 18 18 18 16 16 16 16 16 16 16

Nominal Overall Diameter mm 8.9 9.9 11.1 7.7 9.6 11.0 8.0 9.2 11.4 11.7 9.8 11.3 7.7 8.3 9.0 9.7 10.7 12.2 14.4 17.8 18.8 21.2 23.5 10.4 12.7 17.1 17.6 8.7 10.2 11.7 13.3 6.8 8.8 9.4 10.3 11.9 14.7 12.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 90 115 130 91 110 130 105 130 170 220 115 150 97 122 145 200 220 258 400 552 610 795 900 130 211 410 520 110 150 210 280 86 133 159 195 247 410 180 27


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 3×2×1.5 4×2×1.5 3×2.5 4×2.5 5×2.5 7×2.5 12×2.5 5×4 7×4 12×4 5×6 4×10 5×10 4×16 5×16 4×25 5×25 4×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300

28

AWG /MCM 16 16 14 14 14 14 14 12 12 12 10 8 8 6 6 4 4 1 2/0 3/0 4/0 300 350 500 600

Nominal Overall Diameter mm 14.0 14.6 10.4 10.6 12.3 14.8 18.2 13.6 16.3 20.0 17.4 17.8 19.8 21.1 26.2 26.0 28.6 37.0 19.8 22.5 25.0 24.9 27.8 32.5 39.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 235 210 210 264 288 411 638 382 582 806 640 727 935 1072 1330 1664 2014 3200 950 1200 1400 2000 2340 3150 3920


Caledonian Windmill Cables

Power Cable UL/CSA 1000V PVC/PVC Torsion Resistant Cable 90°C »» Application These cables with increased tolerance to torsion application, UV and oil resistant are specifically designed for wind power applications.

»» Standards UL 758

»» Construction Stranded Copper Conductor Heat Resistant PVC Insulation Heat Resistant PVC Sheath

Conductor: Stranded bare copper according to DIN VDE 0295. Insulation: Special heat resistant PVC. Sheath: Special heat resistant PVC.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant UV Resistant

1000V flexing: -35℃~+90℃; fixed: -40℃~+90℃ 10×OD +/-140°/m FT1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

29


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 4×0.34 4×0.5 6×0.5 10×0.5 12×0.5 3×0.75 4×0.75 5×0.75 7×0.75 10×0.75 12×0.75 14×0.75 16×0.75 18×0.75 21×0.75 25×0.75 32×0.75 36×0.75 40×0.75 41×0.75 50×0.75 4×1 5×1 7×1 10×1 12×1 14×1 16×1 18×1 21×1 25×1 32×1 36×1 40×1 41×1 50×1 2×1.5 3×1.5 30

AWG /MCM 22 20 20 20 20 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 16 16

Nominal Overall Diameter mm 7.1 7.4 8.6 10.8 11.1 7.3 7.9 8.6 10.0 11.0 11.8 12.5 13.2 13.9 15.2 16.9 18.2 19.1 20.5 20.8 23.5 8.3 9.0 10.5 13.0 13.2 13.4 14.1 15.1 16.7 18.4 19.8 20.6 22.4 22.4 24.6 7.9 8.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 86 99 121 165 208 77 100 120 170 200 220 238 271 310 380 490 560 620 729 750 990 100 110 140 220 240 280 310 360 410 500 590 700 800 810 980 75 110


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 4×1.5 5×1.5 7×1.5 10×1.5 12×1.5 14×1.5 16×1.5 18×1.5 21×1.5 25×1.5 32×1.5 36×1.5 40×1.5 41×1.5 50×1.5 3×2.5 4×2.5 5×2.5 7×2.5 10×2.5 12×2.5 19×2.5 3×4 4×4 5×4 7×4 12×4 3×6 4×6 5×6 7×6 4×10 5×10 7×10 4×16 5×16 4×25 5×25 4×35 5×35 4×50

AWG /MCM 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 12 12 12 12 12 10 10 10 10 8 8 8 6 6 4 4 2 2 1

Nominal Overall Diameter mm 8.9 9.7 12.0 13.1 14.3 14.9 15.7 16.8 17.8 20.6 22.2 23.1 25.0 25.0 27.7 8.9 9.7 10.9 14.4 15.8 16.3 20.4 10.8 12.0 13.6 15.9 19.6 13.1 14.6 16.3 19.6 17.4 20.1 23.5 22.6 25.4 26.5 28.2 31.4 35.4 36.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 131 165 210 270 360 420 450 510 590 700 900 980 1030 1050 1200 151 230 250 360 480 580 690 250 270 370 530 740 340 460 550 780 670 870 1150 1000 1250 1580 1900 2100 2600 2800

31


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400

32

AWG /MCM 2 1 2/0 3/0 4/0 300 350 500 600 750

Nominal Overall Diameter mm 12.9 15.6 17.9 21.9 23.1 27.2 27.5 31.2 34.2 39.3

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 460 630 880 1230 1540 1870 2300 2970 3730 4500


Caledonian Windmill Cables

Power Cable UL/CSA 1000V PVC/PVC Screened Torsion Resistant Cable 90°C »» Application These cables with increased tolerance to torsion application, UV and oil resistant are specifically designed for wind power applications.

»» Standards UL 758

»» Construction Stranded Copper Conductor Heat Resistant PVC Insulation Tinned Copper Wire Screen Heat Resistant PVC Sheath

Conductor: Stranded bare copper according to DIN VDE 0295. Insulation: Special heat resistant PVC. Screen: Tinned copper wire wrapped. Sheath: Special heat resistant PVC.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant UV Resistant

1000V flexing: -35℃~+90℃; fixed: -40℃~+90℃ 10×OD +/-90°/m FT1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

33


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 2×2×0.25 4×2×0.25 5×2×0.25 4×0.34 2×2×0.34 4×2×0.34 4×0.5 6×0.5 10×0.5 12×0.5 2×2×0.5 4×2×0.5 3×0.75 4×0.75 5×0.75 7×0.75 8×0.75 12×0.75 18×0.75 25×0.75 32×0.75 40×0.75 41×0.75 50×0.75 2×2×0.75 3×2×0.75 4×2×0.75 8×2×0.75 12×2×0.75 4×1.0 6×1.0 8×1.0 12×1.0 2×1.5 3×1.5 4×1.5 5×1.5 7×1.5 34

AWG /MCM 24 24 24 22 22 22 20 20 20 20 20 20 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 18 18 18 18 16 16 16 16 16

Nominal Overall Diameter mm 8.9 9.9 11.1 7.7 9.6 11.0 8.0 9.2 11.4 11.7 9.8 11.3 7.7 8.3 9.0 9.7 10.7 12.2 14.4 17.8 18.8 21.2 21.2 23.5 10.4 11.5 12.7 17.1 17.6 8.7 10.2 11.7 13.3 6.8 8.8 9.4 10.3 11.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 90 115 130 91 110 130 105 130 170 220 115 150 97 122 145 200 220 258 400 552 610 805 795 900 130 172 211 410 520 110 150 210 280 86 133 159 195 247


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 12×1.5 2×2×1.5 3×2×1.5 4×2×1.5 3×2.5 4×2.5 5×2.5 7×2.5 12×2.5 5×4 7×4 12×4 5×6 4×10 5×10 4×16 5×16 4×25 5×25 4×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500

AWG /MCM 16 16 16 16 14 14 14 14 14 12 12 12 10 8 8 6 6 4 4 1 2/0 3/0 4/0 300 350 500 600 750 1000

Nominal Overall Diameter mm 14.7 12.1 14.0 14.6 10.4 10.6 12.3 14.8 18.2 13.6 16.3 20.0 17.4 17.8 19.8 21.1 26.2 26.0 28.6 37.0 19.8 22.5 25.0 24.9 27.8 33.0 39.0 43.0 46.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 410 180 210 235 210 264 288 411 638 382 582 806 640 727 935 1072 1330 1664 2014 3200 950 1280 1570 2000 2340 3150 3920 5100 6200

35


Caledonian Windmill Cables

Power Cable DLO 2kV Torsion Resistant Cable to UL 44 »» Application These cables are used for main power layout from the nacelle to the base of the wind tower.

»» Standards UL 44 ICEA S-68-516/NEMA WC-8

»» Construction Stranded Copper Conductor Special EPR Insulation Special CPE Sheath

Conductor: Stranded tinned copper according to ASTM B-172/ ASTM B-33. Insulation: Special EPR. XLPO can be offered upon request. Sheath: Special CPE. XLPO can be offered upon request.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant UV Resistant Cold Resistant

36

2000V -40℃~+90℃ flexing: 6×OD; fixed: 4×OD +/-180°/m IEEE 1202/CSA FT4 FT1 Yes Yes CSA C 22.2

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×AWG/MCM 1×14 1×12 1×10 1×8 1×6 1×4 1×2 1×1 1×1/0 1×2/0 1×3/0 1×4/0 1×262 1×313 1×373 1×444 1×535 1×646 1×777 1×929 1×1111

Nominal Overall Diameter mm 5.9 6.3 7.2 8.2 10.1 11.5 12.6 16.1 17.5 18.5 20.2 21.7 24.8 26.4 28.2 30.0 32.2 34.8 37.0 39.5 44.4

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 37 69 100 142 200 286 370 637 715 830 1104 1298 1590 1872 2176 2570 3046 3600 4290 5144 6070

37


Caledonian Windmill Cables

Power Cable NYY 0.6/1kV Power Cable »» Application These cables are designed for power lines of fixed routing in wind tower installation, also used as energy supply cables installed in underground, water, cable ducts, power stations, outdoors, indoors, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not expected.

»» Standards IEC 60502 DIN VDE 0276 part 603

»» Construction Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded copper conductor according to IEC60228/VDE 0295. Insulation: PVC. Filling: Filling compound over the core assembly. Sheath: PVC.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Silicone Free

38

0.6/1kV flexing: -5℃~+50℃; fixed: -40℃~+70℃ Single Core: 15×OD; Multicore:12×OD 50N/mm² 160℃ IEC 60332-1/VDE 0482-332-1-2 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight NYY-J Construction No. of cores×mm² 1×25 rm 1×35 rm 1×50 rm 1×70 rm 3×1.5 re 4×1.5 re 5×1.5 re 7×1.5 re 10×1.5 re 12×1.5 re 14×1.5 re 16×1.5 re 19×1.5 re 24×1.5 re 30×1.5 re 3×2.5 re 4×2.5 re 5×2.5 re 7×2.5 re 10×2.5 re 12×2.5 re 14×2.5 re 19×2.5 re 24×2.5 re 30×2.5 re 3×4 re 4×4 re 5×4 re 3×6 re 4×6 re 5×6 re 3×10 re 4×10 re 5×10 re 3×16 re 4×16 re 5×16 re

Nominal Overall Diameter mm 13 14 15 17 12 13 14 15 18 19 20 21 22 24 26 13 14 15 16 20 20 21 23 26 28 15 16 17 16 17 19 18 19 21 20 22 23 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 380 447 650 864 223 256 293 360 520 560 620 680 760 900 1100 272 316 323 450 630 680 790 990 1300 1400 373 439 510 466 547 640 629 743 899 850 1039 1240 39


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 3×25 rm/16 re 4×25 rm 3×35 sm/16 re 4×35 sm 3×50 sm/25 sm 4×50 sm 3×70 sm/35 sm 4×70 sm 3×95 sm/50 sm 4×95 sm 3×120 sm/70 sm 4×120 sm 3×150 sm/70 sm 4×150 sm 3×185 sm/95 sm 4×185 sm 3×240 sm/120 sm 4×240 sm

Nominal Overall Diameter mm 25 27 27 27 31 31 33 35 38 40 41 43 46 48 50 53 57 60

Nominal Weight kg/km 1595 1620 1718 1916 2383 2639 3196 3576 4271 4746 5281 5813 6408 7263 7909 8905 10162 11430

Nominal Overall Diameter mm 10 11 13 14 15 17 19 21 22 24 27 30 39 11 12 14 14 16 15 17

Nominal Weight kg/km 176 239 380 447 650 864 1132 1405 1710 2086 2669 3305 5400 210 250 316 360 439 400 547

NYY-O Construction No. of cores×mm² 1×10 re 1×16 re 1×25 re 1×35 re 1×50 rm 1×70 rm 1×95 rm 1×120 rm 1×150 rm 1×185 rm 1×240 rm 1×300 rm 1×500 rm 2×1.5 re 2×2.5 re 4×2.5 re 2×4 re 4×4 re 2×6 re 4×6 re 40

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 2×10 re 4×10 re 4×16 re 4×25 rm 4×35 sm 4×50 sm 4×70 sm 4×95 sm

Nominal Overall Diameter mm 17 19 22 27 27 31 35 40

Nominal Weight kg/km 500 743 1039 1620 1916 2639 3576 4746

re: round conducter, single wire rm: round conducter, multi wire sm: sectional conductor

www.caledonian-cables.co.uk www.addison-cables.com

41


Caledonian Windmill Cables

Power Cable NAYY 0.6/1kV Power/Control Cable »» Application These cables are designed for power lines of fixed routing in wind tower installation, also used as energy supply cables installed in underground, water, cable ducts, power stations, outdoors, indoors, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not expected.

»» Standards IEC 60502-1 DIN VDE 0276 part 603

»» Construction Solid Aluminium Conductor PVC Insulation Extruded Inner Covering PVC Sheath

Conductor: Solid aluminium wires, round or sector shape according to VDE 0295/IEC 60228. Insulation: PVC. Inner Covering: Extruded inner covering. Sheath: PVC.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Silicone Free

42

0.6/1kV flexing: -5℃~+50℃; fixed: -40℃~+70℃ 12×OD 30N/mm² 160℃ VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 1×25 re 1×50 rm 1×70 rm 1×95 rm 1×120 rm 1×150 rm 1×185 rm 1×240 rm 1×300 rm 1×400 rm 1×500 rm 1×630 rm 4×25 re 4×35 re 4×50 se 4×70 se 4×120 se 4×150 se 4×185 se 4×240 se 4G25 re 4G35 re 4G50 se 4G70 se 4G95 se 4G120 se 4G150 se 4G185 se 4G240 se 4G240 sm 4G150 se+1×1.5 re 4G150 se+2×1.5 re G: with green-yellow earth core

Nominal Overall Diameter mm 13.0 16.5 18.5 21.0 22.5 23.5 25.5 28.5 31.5 35.5 39.0 43.0 27.0 29.0 30.5 34.5 42.5 45.5 50.5 54.0 27.0 29.0 30.5 34.5 38.5 42.5 45.5 50.5 54.0 55.5 45.5 45.5

Nominal Weight kg/km 200 310 400 520 600 700 870 1090 1335 1685 2075 2540 1000 1200 1350 1750 2630 3000 3780 4740 1000 1200 1350 1750 2250 2750 3200 3950 4700 4960 3010 3020

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

43


Caledonian Windmill Cables

Power Cable N2XY 0.6/1kV Power Cable »» Application These cables are designed for energy supply, suitable for installed in underground, water, cable ducts, power stations, outdoors, indoors, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not expected.

»» Standards IEC 60502 DIN VDE 0276 part 603

»» Construction Stranded Copper Conductor XLPE Insulation PVC Sheath

Conductor: Stranded bare copper conductor according to VDE 0295/IEC 60228. Insulation: Cross-linked polyethylene (XLPE). Inner Covering: Extruded inner covering. Sheath: PVC.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Silicone Free

44

0.6/1kV -40℃~+ 70℃ 15×OD 50N/mm² 250℃ VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 1×95 1×150 1×185 1×240 1×300 1×400 1×500 4G35 4G50 4G75 4G95 4G120 4G150 4G185 4G240 G: with green-yellow earth core

Nominal Overall Diameter mm 21.0 25.0 27.0 30.0 32.0 36.0 40.0 31.0 33.0 38.0 42.0 46.0 50.0 55.0 70.0

Nominal Weight kg/km 1200 1800 2200 2800 3300 4200 5400 2200 2400 3100 4200 5100 6300 8000 10000

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

45


Caledonian Windmill Cables

Power Cable N2XH 0.6/1kV LSOH Power Cable »» Application These cables are designed for energy supply, suitable for fixed installation in dry, damp or wet environments; in, above, on and beneath plaster as well as in masonary walls and in concrete, also suitable for outdoor applications and in underground by using in conduits or tubes.

»» Standards

Stranded Copper Conductor XLPE Insulation

DIN VDE 0276 part 604

Thermoplastic polyolefin Sheath

»» Construction Conductor: Bare copper conductor wire according to VDE 0295/IEC 60228. Insulation: Halogen free cross-linked polyethylene (XLPE), Type 2XI1. Inner Covering: Overall filled inner sheath covered by filling compound or wrapped tape. Sheath: Thermoplastic polyolefin, Type HM4.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Corrosive Gases Smoke Density

0.6/1kV -30℃~+ 90℃ 15×OD DIN VDE 0482 part 266-2/BS 4066 part 3/EN 50266-2/IEC 60332-3 DIN VDE 0482 part 267/EN 50267-2-1/IEC 60754 DIN VDE 0482 part 267/EN 50267-2-2/IEC 60754 DIN VDE 0482 part 268/HD 606/EN 50268-1+2/ IEC 61034/BS 7622 part 1+2

»» Dimensions and Weight Construction No. of cores×mm² 1×185 rm 1×240 rm 1×300 rm rm: round conducter, multi wire

46

Nominal Overall Diameter mm

25.0 28.0 30.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 1910 2370 2970


Caledonian Windmill Cables

Power Cable NA2XH 0.6/1kV LSOH Power Cable »» Application These cables are designed for energy supply in tower, suitable for outdoors, in concrete, indoors and in cable ducts where no mechanical damage is to be expected.

»» Standards DIN VDE 0276 part 604

»» Construction Aluminium Conductor XLPE Insulation Polyolefin Sheath

Conductor: Sector-shaped solid or round solid/stranded aluminium wire. Insulation: Cross-linked polyethylene (XLPE). Filling: Extruded halogen-free filling compound. Sheath: Polyolefin, Type HM4. PVC sheath can be offered upon request (NA2XY).

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Flame Retardant Halogen Free Corrosive Gases Smoke Density

0.6/1kV -40℃~+ 90℃ 15×OD 250℃ DIN VDE 0482 Part 266-2/BS 4066 Part 3/EN 50266-2/IEC 60332-1 DIN VDE 0482 Part 267/EN 50267-2-1/IEC 60754 VDE 0482 Part 267/DIN EN 50267-2-2/IEC 60754 DIN VDE 0482 Part 268/HD 606/EN 50268-12/IEC 61034

www.caledonian-cables.co.uk www.addison-cables.com

47


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×95 3×120 3×150 3×185 3×240 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240 G: with green-yellow earth core

Nominal Overall Diameter mm 18.0 19.5 20.5 22.5 25.0 27.5 30.5 34.5 38.5 31.0 34.5 37.5 41.0 45.0 26.0 27.5 31.5 34.5 38.5 43.5 46.5 50.5

×: without green-yellow earth core

48

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 405 490 580 700 880 1080 1370 1760 2200 1300 1620 1930 2380 2970 890 1030 1350 1710 2120 2600 3160 3950


Caledonian Windmill Cables

Power Cable H05BQ-F/H07BQ-F »» Application These cables are used as power cables for high mechanical stresses, in particular for abrasion and grinding stresses, suitable for use in dry, damp and wet rooms and outdoors, for connecting electric tools and lamps also on construction sites.

»» Standards HD 22.10 S1

»» Construction

Stranded Copper Conductor EPR Insulation PUR Sheath

Conductor: Stranded bare copper, class 5 according to HD 383. Insulation: EPR compound type EI6. Sheath: Polyurethane.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius

300/500V (H05BQ-F);450/750V (H07BQ-F) -40℃~+90℃ fixed: 4×OD; flexing: 6×OD

www.caledonian-cables.co.uk www.addison-cables.com

49


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight H05BQ-F Construction No. of cores×mm² 2×0.75 3G0.75 4G0.75 5G0.75 2×1 3G1 4G1 5G1

Nominal Overall Diameter mm 6.6 7.2 7.8 8.8 7.1 7.5 8.2 9.2

Nominal Weight kg/km 50 60 80 100 60 70 90 110

Nominal Overall Diameter mm 8.7 9.2 10.3 11.3 10.3 11.0 12.3 13.6 12.2 12.9 14.5 16.0 13.5 14.6 16.2 17.9 17.8 19.1 21.1 23.2 20.4 22.1 24.2 26.9

Nominal Weight kg/km 90 110 130 170 120 160 200 250 170 230 280 360 220 300 380 470 380 520 650 800 540 750 950 1160

H07BQ-F Construction No. of cores×mm² 2×1.5 3G1.5 4G1.5 5G1.5 2×2.5 3G2.5 4G2.5 5G2.5 2×4 3G4 4G4 5G4 2×6 3G6 4G6 5G6 2×10 3G10 4G10 5G10 2×16 3G16 4G16 5G16 G: with green-yellow earth core ×: without green-yellow earth core

50

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable H05V-K/H07V-K Internal Wiring Cable »» Application These cables are designed for the intenal wiring of devices, distributor and switchboards and also for protective laying to the lightings, suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits.

»» Standards DIN VDE 0281 part 3 HD 21.3 S3 IEC 60227-3

»» Construction

Stranded Copper Conductor PVC Insulation

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/HD 383/ IEC 60228. Insulation: PVC.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Silicone Free

300/500V(H05V-K); 450/750V(H07V-K) flexing: -5℃~+70℃; fixed: -30℃~+80℃ 15×OD VDE 0482-332-1-2/IEC 60332-1 Yes

www.caledonian-cables.co.uk www.addison-cables.com

51


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight H05V-K Construction No. of cores×mm² 1×0.5 1×0.75 1×1

Nominal Overall Diameter mm 2.1 2.4 2.6

Nominal Weight kg/km 9 12 15

Nominal Overall Diameter mm 3.0 3.7 4.3 4.9 6.5 8.0 9.8 11.0 13.0 15.5 17.0 19.7 21.3 23.5 27.4

Nominal Weight kg/km 24 35 51 71 118 180 278 375 560 780 952 1200 1505 1845 2400

H07V-K Construction No. of cores×mm² 1×1.5 1×2.5 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

52

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable S-3GSHXOEU HFFR 0.6/1 kV & UL 1000V 90°C »» Application These cables are designed for use at medium mechanical stresses in wind turbines.

»» Standards UL 758 DIN VDE 0250 DIN VED 0282

»» Construction Stranded Copper Conductor Rubber Insulation EVA Sheath

Conductor: Stranded bare copper, fine wire class 5 according to IEC 60228 / DIN EN 60228. Insulation: Rubber compound. Sheath: EVA.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Cooling Fluid Resistance Ozone Resistant UV Resistant

600/1000V (DIN VDE 0250)/ 1000V (AWM 758) -40℃~+90℃ flexing: 6×OD; fixed: 4×OD 250℃ IEC 60332-1 EN 50267-2-1/IEC 60754 DIN EN 50267-2 IEC 61034 Yes Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

53


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 3×1.5 4×1.5 5×1.5 3×2.5 4×2.5 5×2.5 3×4 4×4 3×6 4×6 2×10 3×10 4×10 5×10 3×16 4×16 5×16 1×25 3×25 4×25 5×25 1×35 3×35 4×35 5×35 1×50 3×50 4×50 5×50 1×70 3×70 4×70 5×70 1×95 3×95 1×120 3×120

54

Nominal Overall Diameter mm 10.3 11.3 12.5 12.5 13.0 14.5 14.5 15.5 15.5 17.5 18.5 20.0 22.0 25.5 23.0 26.0 28.5 13.0 28.0 30.5 34.0 15.0 31.5 34.5 38.0 17.0 36.0 40.0 44.0 19.5 41.5 46.5 51.0 21.5 47.5 24.0 51.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 142 182 224 217 265 326 313 383 407 514 560 688 642 1095 946 1242 1501 364 1416 1746 2173 491 1894 2338 2849 682 2564 3236 3941 936 3466 4504 5515 1209 4580 1487 5517


Caledonian Windmill Cables

Power Cable S-3GSHCOEU 0.6/1 kV & UL 1000V 90°C »» Application These cables are designed for use at medium mechanical stresses in wind turbines.

»» Standards UL 758 DIN VDE 0250

Stranded Copper Conductor Rubber Insulation Tinned Copper Braid Screen

»» Construction

CPE Sheath

Conductor: Stranded bare copper, class 5 according to IEC 60228/DIN EN 60228. Insulation: Rubber compound. Screen: Tinned copper wires. Mixed braid of tinned copper wires and polyester yarn can be offered upon request. Sheath: CPE.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Maximum Permissible Tensile Load Minimum Bending Radius Short-circuit Temperature Flame Retardant Oil Resistant Ozone Resistant UV Resistant

600/1000V (DIN VDE 0250)/ 1000V (AWM 758) -40℃~+90℃ 15 N/mm² flexing: 10×OD; fixed: 6×OD 250℃ IEC 60332-1 Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×95 1×120 1×185 1×240

Nominal Overall Diameter mm 23.0 26.0 30.5 34.0 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 1120 1607 2341 2953 55


Caledonian Windmill Cables

Power Cable Halogen Free Torsion Resistant Fire Alarm Cable 24V »» Application These fire alarm cables are designed for the torsion applications in the loop section of wind turbines.

»» Standards

Stranded Copper Conductor Fluorine Polymer Insulation

IEC 60502 DIN VDE 0250

Tinsel Braid or Spiral Shield Halogen Free TPU Sheath

»» Construction Conductor: Stranded copper wires, class 6 according to DIN VDE 0295/ IEC 60228. Insulation: Fluorine polymer. Screen: Tinsel braid or spiral shield. Sheath: Flame retardant halogen-free TPU.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Halogen Free Oil Resistant Abrasion Resistant

24V -50℃~+90℃ 7.5×OD +/-1080°/5m IEC 60332-3 IEC 60754 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 4×0.75

56

Nominal Overall Diameter mm 6.6

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 82


Caledonian Windmill Cables

Power Cable High Temperature Resistant Cables +145°C 0.6/1kV »» Application These cables are specifically designed for connecting generator output of thermal class (B), motors, transformers and relays requiring for high temperature resistant.

»» Standards IEC 60502

»» Construction Stranded Copper Conductor Halogen Free XLPO Insulation

Conductor: Stranded tinned copper wires, class 5/class 6 according to DIN VDE 0295/ IEC 60228. Insulation: Halogen-free XLPO.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Ozone Resistant UV Resistant Cold Resistant

0.6/1kV -55℃~+145℃ 6×OD IEC 60332-3 IEC 60754 IEC 60754 IEC 61034 Yes Yes Yes CSA C 22.2

www.caledonian-cables.co.uk www.addison-cables.com

57


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight Construction No. of cores×mm² 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400

58

Nominal Overall Diameter mm 5.4 6.8 8.5 10.3 11.8 13.9 16.0 18.5 20.5 22.1 24.8 27.7 37.8 38.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 70 119 180 270 373 528 728 966 1230 1530 1880 2500 3910 4870


Caledonian Windmill Cables

Power Cable EPR/HFXLEVA Medium Voltage Torsion Resistant Cable »» Application These cables having torsion resistant, good bending and halogen free are specifically designed for the torsion applications in wind turbines, suitable for transmit energy from the generator to the transformer, which is usually located at the base of the tower.

»» Standards IEC 60502

»» Construction Stranded Copper Conductor EPR Insulation HFXLEVA Sheath

Conductor: Stranded tinned copper, class 5/class 6 according to IEC 60228. Insulation: EPR. Sheath: HFXLEVA.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Ozone Resistant UV Resistant Cold Resistant

1.8/3kV -40℃~+125℃ 6×OD +/-180°/m IEC 60332-3 IEC 60754 IEC 60754 IEC 61034 Yes Yes Yes CSA C 22.2

www.caledonian-cables.co.uk www.addison-cables.com

59


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight 1.8/3kV Construction No. of cores×mm² 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400

60

Nominal Overall Diameter mm 12.9 14.3 16.5 18.6 21.6 23.7 26.2 29.9 32.1 34.5 39.3

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 516 670 840 1112 1520 1880 2513 3272 3534 4020 5640


Caledonian Windmill Cables

Power Cable NTSCGEWOEU Medium Voltage Torsion Resistant Cable 3.6/6kV »» Application These medium-voltage cables are designed for energy transmission, also for loop applications.

»» Standards

Stranded Copper Conductor Special EPR Insulation

DIN VDE 0250-813

CR/CM Sheath

»» Construction Conductor: Stranded tinned copper wires according to DIN VDE 0295. Insulation: Special EPR with inner and outer conducting layer. Sheath: CM/CR.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Oil Resistant Ozone Resistant UV Resistant

3.6/6kV -40℃~+90℃ 10×OD +/-100°/m Yes Yes Yes

»» Dimensions and Weight 3.6/6kV Construction No. of cores×mm² 3×35/35 3×50/50 3×70/70 3×95/95 1×240 1×300

Nominal Overall Diameter mm 61.0 69.0 73.0 80.0 42.8 44.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 5723 6596 7881 10612 3100 3800

61


Caledonian Windmill Cables

Power Cable N2XS2Y Medium Voltage Power Cable »» Application These cables are commonly used in wind parks, suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

»» Standards IEC 60502 DIN VDE 0276 part 620 HD 620 S1

»» Construction XLPE Insulation Insulation Screen Stranded Copper Conductor Conductor Screen Copper Wires + Copper Tape Screen PE Sheath

Conductor: Stranded bare copper conductor according to HD 383. Conductor Screen: Semiconducting compound. Insulation: XLPE, PE-compound DIX8 to HD 620.1. Insulation Screen: Semiconducting compound. Tape: Conductive material. Screen: Braiding of copper wires with one or two tapes applied helically. Tape: Separation tape. Sheath: PE, compound DMP2 to HD 620.1.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures

62

6/10 kV, 12/20 kV, 18/30 kV -20℃~+90℃

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Minimum Bending Radius Short-circuit Temperature

15×OD 250℃

»» Dimensions and Weight 6/10 kV Construction No. of cores×mm² 1×35 rm/16 1×50 rm/16 1×70 rm/16 1×95 rm/16 1×120 rm/16 1×150 rm/16 1×150 rm/25 1×185 rm/16 1×185 rm/25 1×240 rm/16 1×240 rm/25 1×300 rm/25 1×400 rm/35 1×500 rm/35

Nominal Overall Diameter mm 25.5 26.5 28.5 29.5 31.5 32.5 32.5 34.5 34.5 36.5 36.5 38.5 42.5 45.5

Nominal Weight kg/km 910 990 1205 1520 1760 2020 2130 2360 2470 2960 3020 3630 4560 5580

Nominal Overall Diameter mm 27.5 28.5 30.5 31.5 33.5 34.5 34.5 36.5 36.5 39.0 39.0 41.0 44.5 47.5

Nominal Weight kg/km 960 1160 1410 1670 1960 2220 2310 2620 2670 3160 3270 3880 4820 5860

12/20 kV Construction No. of cores×mm² 1×35 rm/16 1×50 rm/16 1×70 rm/16 1×95 rm/16 1×120 rm/16 1×150 rm/16 1×150 rm/25 1×185 rm/16 1×185 rm/25 1×240 rm/16 1×240 rm/25 1×300 rm/25 1×400 rm/35 1×500 rm/35

www.caledonian-cables.co.uk www.addison-cables.com

63


Caledonian Windmill Cables

Power Cable 18/30 kV Construction No. of cores×mm² 1×50 rm/16 1×70 rm/16 1×95 rm/16 1×120 rm/16 1×150 rm/25 1×185 rm/25 1×240 rm/25 1×300 rm/25 1×400 rm/25 1×500 rm/25

64

Nominal Overall Diameter mm 35.5 37.5 38.5 40.5 41.5 43.5 45.5 48.5 51.5 54.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 1410 1660 1970 2220 2650 2980 3570 4220 5170 6260


Caledonian Windmill Cables

Power Cable NA2XS(F)2Y RE/RM Medium Voltage Power Cable »» Application These cables are commonly used in wind turbines, suitable for indoor installation and in cable ducts, outdoors, underground and in water.

»» Standards IEC 60502-2 DIN VDE 0276 part 620

»» Construction XLPE Insulation Insulation Screen Solid/Stranded Aluminium Conductor Conductor Screen Copper Wires + Copper Tape Screen PE Sheath

Conductor: Circular solid (RE) or stranded (RM) aluminium conductor. Conductor Screen: Semiconducting compound. Insulation: XLPE. Insulation Screen: Semiconducting compound. Tape: Semiconducting swellable tape. Screen: Braiding of copper wires with copper tape. Tape: Separation tape. Sheath: PE.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Longitudinally Water-Tight Halogen Free

6/10 kV, 12/20 kV, 18/30 kV -40℃~+90℃ 15×OD 250℃ Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

65


Caledonian Windmill Cables

Power Cable Lead Free

Yes

»» Dimensions and Weight 6/10 kV Construction No. of cores×mm² 1×70 re 1×95 re 1×120 re 1×150 re 1×185 re 1×240 re 1×300 re 1×400 re 1×500 re 1×630 re 1×800 re 1×1000 re 1×35 rm 1×50 rm 1×70 rm 1×95 rm 1×120 rm 1×150 rm 1×185 rm 1×240 rm 1×300 rm 1×400 rm 1×500 rm 1×630 rm 1×800 rm 1×1000 rm

Nominal Overall Diameter mm 26.5 26.5 28.5 29.5 31.5 33.5 36.5 40.5 43.5 45.5 49.5 53.5 25.5 26.5 28.5 29.0 31.0 32.0 34.0 36.0 38.5 42.5 45.5 47.5 52.5 56.5

Nominal Weight kg/km 760 860 930 1130 1230 1470 1670 2060 2400 2790 3340 4000 600 670 770 880 950 1150 1250 1500 1700 2100 2450 2850 3490 4080

Nominal Overall Diameter mm 30.5 31.5 32.5 33.5 35.5 38.5 40.5 43.5 46.5

Nominal Weight kg/km 910 1030 1130 1320 1470 1720 1960 2300 2740

12/20 kV Construction No. of cores×mm² 1×70 re 1×95 re 1×120 re 1×150 re 1×185 re 1×240 re 1×300 re 1×400 re 1×500 re

66

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 1×630 re 1×800 re 1×1000 re 1×50 rm 1×70 rm 1×95 rm 1×120 rm 1×150 rm 1×185 rm 1×240 rm 1×300 rm 1×400 rm 1×500 rm 1×630 rm 1×800 rm 1×1000 rm

Nominal Overall Diameter mm 49.5 53.5 57.5 30.5 32.5 33.5 35.0 36.0 38.0 41.0 43.0 46.0 49.0 51.5 57.5 60.5

Nominal Weight kg/km 3070 3680 4360 820 930 1050 1150 1350 1500 1750 2000 2350 2800 3140 3840 4460

Nominal Overall Diameter mm 34.5 35.5 37.5 38.5 40.5 42.5 45.5 48.5 51.5 55.5 59.5 63.5 35.0 37.0 38.0 40.0 41.0 43.0 45.0 48.0 51.0 54.0 57.5 62.5 66.5

Nominal Weight kg/km 1180 1320 1420 1670 1810 2010 2300 2740 3140 3480 4100 4800 1100 1200 1350 1450 1700 1850 2050 2350 2800 3200 3570 4280 4970

18/30 kV Construction No. of cores×mm² 1×70 re 1×95 re 1×120 re 1×150 re 1×185 re 1×240 re 1×300 re 1×400 re 1×500 re 1×630 re 1×800 re 1×1000 re 1×50 rm 1×70 rm 1×95 rm 1×120 rm 1×150 rm 1×185 rm 1×240 rm 1×300 rm 1×400 rm 1×500 rm 1×630 rm 1×800 rm 1×1000 rm

www.caledonian-cables.co.uk www.addison-cables.com

67


Caledonian Windmill Cables

Power Cable NTSCGEWOEU Medium Voltage Torsion Resistant Cable 12~35kV »» Application These cables are specifically designed for carrying medium voltage energy from the transformer in the nacelle to the bottom of the tower.

»» Standards DIN VDE 0250 Part 813

»» Construction Stranded Tinned Copper Conductor Inner Conductor Layer Heat Resistant EPR Insulation Outer Conductor Layer Heat & Cold Resistant CM/CR Sheath

Conductor: Stranded tinned copper, class 5 according to DIN VDE 0295/IEC 60228. Inner Conductor Layer: Semiconductive rubber compound. Insulation: Heat resistant EPR. Outer Conductor Layer: Semiconductive rubber compound. Sheath: Heat and cold resistant special rubber compound based on CM (Chlorinated synthetic rubber) or CR (Chloroprene rubber).

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Oil Resistant Ozone Resistant UV Resistant 68

12/20kV, 18/30kV, 20/35kV -40℃~+90℃ 10×OD +/100°/m 20N/mm² 200℃ DIN EN 502652-1/IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight 12/20kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70

Nominal Overall Diameter mm 61.2 65.9 69.5 73.5

Nominal Weight kg/km 4780 5700 6630 7840

Nominal Overall Diameter mm 79.1 80.5 83.1 89.0

Nominal Weight kg/km 7520 8050 8920 10600

Nominal Overall Diameter mm 86.2 90.8 93.0 96.1

Nominal Weight kg/km 8820 10000 10830 12050

18/30kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70 20/35kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70

www.caledonian-cables.co.uk www.addison-cables.com

69


Caledonian Windmill Cables

Power Cable (N)TSCGEHXOEU Medium Voltage LSOH Torsion Resistant Cable »» Application These LSOH cables are specifically designed for special application condition in wind turbines, used for economical transmission of large energy rates with medium voltage.

»» Standards DIN VDE 0250 Part 813

»» Construction Stranded Copper Conductor Inner Conductor Layer Heat Resistant HFEPR Insulation Outer Conductor Layer Optional Inner Sheath Heat & Cold Resistant HFEVA Sheath

Conductor: Stranded tinned/bare copper, class 5 according to DIN VDE 0295 IEC 60228. Inner Conductor Layer: Semiconductive halogen free rubber compound. Insulation: Halogen free, heat resistant insulation based on EPR. Outer Conductor Layer: Semiconductive rubber compound. Optional Inner Sheath: Extruded special rubber compound. Sheath: Halogen free special rubber compound based on EVA.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Torsion Application Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant Halogen Free Corrosive Gases 70

8.7/15 kV, 12/20 kV,18/30 kV,20/35 kV -40℃~+90℃ 10×OD +/100°/m 15N/mm² 250℃ DIN EN 60332-1 IEC 60754 DIN EN 50267-2-3

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable Smoke Density Oil Resistant Ozone Resistant UV Resistant Silicone Free

DIN EN 50268-2 Yes Yes Yes Yes

»» Dimensions and Weight 8.7/15kV Construction No. of cores×mm² 3×50/50 3×70/70 3×95+3×16.7

Nominal Overall Diameter mm 51.5 57.5 57.5

Nominal Weight kg/km 4050 5250 5600

Nominal Overall Diameter mm 51.5 54.5 56.5 59.0 65.5

Nominal Weight kg/km 3400 4000 4700 5700 6900

Nominal Overall Diameter mm 67.5 67.5 69.5 71.5 76.5

Nominal Weight kg/km 5300 5600 6300 7100 8500

Nominal Overall Diameter mm 73.0 73.0 73.0 76.0 78.0

Nominal Weight kg/km 6100 6500 6800 7900 9100

12/20kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70 3×95/95 18/30kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70 3×95/95 20/35 kV Construction No. of cores×mm² 3×25/25 3×35/35 3×50/50 3×70/70 3×95/95

www.caledonian-cables.co.uk www.addison-cables.com

71


Caledonian Windmill Cables

Power Cable Medium Voltage High Temperature Resistant Cables +180°C »» Application These cables are specifically designed for applications requiring for high temperature and oil resistant, suitable used for linking generators to transformers positioned up in the nacelle.

»» Standards IEC 60092

»» Construction Stranded Copper Conductor Silicone Insulation PUR Varnished Synthetic Yarn Braid

Conductor: Stranded tinned copper wires, class 5 according to IEC 60228. Tape: Polyester tape (up 16 mm²), Semi-conductive layer (only for 6.6 and 13.8 kV). Insulation: Silicone rubber insulation. Braid: PUR varnished synthetic yarn braid.

»» Technical Data Rated Voltage U0/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Corrosive Gases Smoke Density Oil Resistant Ozone Resistant UV Resistant Cold Resistant 72

1.1kV-15kV -55℃~+180℃ 6×OD (1.1kV); 12×OD (>=1.1kV) IEC 60332-1/IEC 60332-3 IEC 60754 IEC 60754 IEC 61034 Yes Yes Yes CSA C 22.2

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Power Cable »» Dimensions and Weight 1.1kV Construction No. of cores×mm² 1×2.5 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

Nominal Overall Diameter mm 4.5 5.0 5.4 6.4 8.6 10.3 11.6 13.6 15.7 17.9 19.8 21.9 24.3 26.9

Nominal Weight kg/km 36 52 69 111 177 267 365 510 701 926 1154 1432 1761 2284

Nominal Overall Diameter mm 6.3 7.3 8.2 10.4 12.0 13.2 15.4 17.5 19.5 21.4 23.1 25.1 27.5

Nominal Weight kg/km 54 90 135 208 302 401 559 775 981 1215 1481 1798 2314

Nominal Overall Diameter mm 7.6 8.0

Nominal Weight kg/km 81 99

3.3-4.2kV Construction No. of cores×mm² 1×2.5 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 6.6-7.2kV Construction No. of cores×mm² 1×4 1×6

www.caledonian-cables.co.uk www.addison-cables.com

73


Caledonian Windmill Cables

Power Cable Construction No. of cores×mm² 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

Nominal Overall Diameter mm 9.0 11.3 12.9 14.1 16.3 18.3 20.2 22.0 24.1 26.1 28.3

Nominal Weight kg/km 145 225 322 423 584 785 1006 1238 1525 1844 2355

Nominal Overall Diameter mm 12.1 14.0 15.5 16.7 18.5 20.6 22.4 24.2 26.5 28.5 30.7

Nominal Weight kg/km 205 288 390 497 655 864 1093 1332 1637 1966 2486

13.8-15.0kV Construction No. of cores×mm² 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

74

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable H07RN-F 450/750V »» Application These cables are designed for use at medium mechanical stresses in wind turbines. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground.

»» Standards DIN VDE 0282 part 4 HD 22.4 S4 HD 22.1 BS 7919 IEC 60245-4

»» Construction Stranded Copper Conductor EI4 Insulation Rubber Sheath

Conductor: Stranded bare copper conductor, class 5 acc. to IEC 60228/DIN VDE 0295. Insulation: Rubber type EI4 according to HD 22.1/DIN VDE 0282 part 1. Sheath: Rubber compound according to HD 22.1/DIN VDE 0282 part 1.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Maximum Permissible Tensile Load Short-circuit Temperature Flame Retardant

450/750V -30℃~+60℃ flexing:7.5×OD; fixed: 4×OD 15 N/mm² 250℃ IEC 60332-1/DIN VDE 0472 part 804

www.caledonian-cables.co.uk www.addison-cables.com

75


Caledonian Windmill Cables

Control Cable Oil Resistant Ozone Resistant Weather Resistant

Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 1×1.5 1×2.5 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 2×1 2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 3G1 3G1.5 3G2.5 3G4 3G6 3G10 3G16 3G25 3G35 3G50 3G70 3G95

76

Nominal Overall Diameter mm 6.4 7.1 8.1 8.9 10.7 12.1 14.3 16.1 18.6 21.0 23.4 25.7 28.3 31.0 34.5 37.7 42.1 46.7 8.9 9.8 11.7 13.5 15.0 20.2 23.0 27.5 9.5 10.6 12.5 14.5 16.1 21.7 24.7 29.6 33.2 38.5 43.4 48.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 58 71 100 130 230 290 420 530 750 960 1250 1560 1900 2300 2950 3600 4600 6000 98 135 193 280 330 586 810 1160 130 165 235 320 420 810 1050 1250 1900 2600 3400 4450


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 3G120 3G150 3G185 3G240 3G300 4G1 4G1.5 4G2.5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 4G150 4G185 4G240 4G300 5G1.5 5G2.5 5G4 5G6 5G10 5G16 5G25 5G35 5G50 5G70 7G1.5 7G2.5 7G4 12G1.5 12G2.5 18G2.5 19G1.5 19G2.5 24G1.5 24G2.5 G: with green-yellow earth core

Nominal Overall Diameter mm 53.7 59.0 64.5 73.5 81.0 10.6 11.7 13.8 16.0 17.9 23.7 27.0 32.8 36.8 42.6 48.4 54.7 59.5 65.5 72.0 81.5 90.5 12.8 15.2 17.8 19.9 26.0 29.9 36.2 41.3 45.4 48.9 16.0 18.3 21.4 20.0 23.4 27.7 23.5 28.3 27.5 32.6

Nominal Weight kg/km 5180 6500 7860 10224 12620 150 200 290 395 540 950 1260 1860 2380 3190 4260 5600 6830 8320 9800 12100 15200 240 345 485 650 1200 1550 2250 2750 3950 4740 375 520 681 460 760 850 810 1075 1015 1390

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

77


Caledonian Windmill Cables

Control Cable H07RN-F & UL/CSA 600V 90°C »» Application These cables are designed for use at medium mechanical stresses in wind turbines. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground.

»» Standards HD 22.4 S4 UL 758

»» Construction Stranded Copper Conductor EPR Insulation CPE Sheath

Conductor: Stranded bare copper, fine wire class 5 according to IEC 60228/DIN VDE 0295/HD 383. Insulation: EPR class 28. Sheath: CPE class 42.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Flame Retardant Oil Resistant Ozone Resistant UV Resistant

78

600V(UL/CSA) -40℃~+90℃ flexing: 6×OD; fixed: 4×OD 250℃ DIN EN 60332-1-2/IEC 60332-1-2 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 1G25 1×50 1G95 1×150 1×240 1×300 1×400 3G1 3G1.5 3G2.5 3G4 3G6 3G10 3×35 3×50 3×70 3×95 3×240 4G1.5 4G2.5 4G4 4G6 4G10 5G1.5 5G2.5 5G4 5G6 7G1.5 7G2.5 G: with yellow/green earth core

Nominal Overall Diameter mm 13.9 17.8 22.4 27.1 32.1 35.0 40.0 9.6 9.8 11.5 16.0 17.1 22.9 31.5 35.5 41.0 46.0 70.5 10.5 12.5 14.5 18.4 25.0 11.5 13.5 18.7 20.1 13.5 15.5

Nominal Weight kg/km 385 680 1142 1845 2820 3390 4370 130 160 220 320 420 810 1850 2590 3560 4500 10260 200 280 380 540 950 250 350 485 650 400 540

×: without yellow/green earth core

www.caledonian-cables.co.uk www.addison-cables.com

79


Caledonian Windmill Cables

Control Cable (H)07RN-F HFFR & UL/CSA 600V 90°C »» Application These cables are designed for use at medium mechanical stresses in wind turbines. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground.

»» Standards HD 22.4 UL 758

»» Construction Stranded Copper Conductor EPR Insulation EVA Sheath

Conductor: Stranded bare copper, fine wire class 5 according to DIN VDE 0295. Insulation: EPR class 28. Sheath: EVA.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Short-circuit Temperature Flame Retardant Corrosive Gases Smoke Density Oil Resistant UV Resistant 80

600V(UL/CSA) -40℃~+90℃ flexing: 6×OD; fixed: 4×OD 250℃ EN 50265-2-1/IEC 60332-1 EN 50267-2 EN 50268-2 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 1G25 1×50 1G95 1×150 1×240 1×300 3G1.5 3G2.5 3×25 3×50 3×70 3×95 3×240 4G1.5 4G2.5 4G4 5G1.5 5G2.5 7G1.5 7G2.5 G: with yellow/green earth core

Nominal Overall Diameter mm 13.9 17.8 22.4 27.1 32.1 35.0 9.8 11.5 27.5 35.5 41.0 46.0 70.5 10.5 12.5 14.5 11.5 13.5 13.5 15.5

Nominal Weight kg/km 420 790 1145 1845 2820 3390 165 227 1435 2598 3570 4510 10280 208 289 394 258 362 412 554

×: without yellow/green earth core

www.caledonian-cables.co.uk www.addison-cables.com

81


Caledonian Windmill Cables

Control Cable H05VV5-F 300/500V »» Application These cables are used as supply or interconnecting cables for measuring, controlling and regulating for light and medium mechanical stresses.

»» Standards HD 21.13 S1 DIN VDE 0281 Part. 13/5/96

»» Construction Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded bare copper, class 5/class 6 according to IEC 60228. Insulation: PVC Type YI 4. Sheath: PVC oil resistant Type YM 5.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Ozone Resistant Silicone Free

82

300/500 V flexing: -15℃~+80℃; fixed: -40℃~+80℃ flexing: 10×OD; fixed: 6×OD IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 41G0.75 50G0.75 2×1 3G1 4G1 5G1 7G1 12G1 14G1 18G1 25G1 34G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 34G1.5 50G1.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 18G2.5 25G2.5

Nominal Overall Diameter mm 6.5 7.0 7.8 9.4 11.5 13.8 16.8 21.5 23.6 6.2 6.7 7.5 8.0 9.6 12.3 13.9 14.4 17.5 21.4 7.7 7.9 8.9 10.3 11.9 14.3 17.2 21.2 24.5 30.3 9.4 10.8 11.8 14.0 17.3 20.5 25.5

Nominal Weight kg/km 57 70 89 130 174 259 362 602 723 54 66 82 105 149 210 267 302 418 622 75 93 117 143 220 292 435 620 842 1305 144 180 229 300 453 684 943

G: with yellow/green earth core ×: without yellow/green earth core www.caledonian-cables.co.uk www.addison-cables.com

83


Caledonian Windmill Cables

Control Cable H05VVC4V5-K 300/500V »» Application These screened cables are used as supply or interconnecting cable for measuring, controlling and regulating for light and medium mechanical stresses.

»» Standards HD 21.13 S1 DIN VDE 0281 Part. 13/5/96

»» Construction Stranded Copper Conductor PVC Insulation PVC Inner Sheath Tinned Copper Braid PVC Outer Sheath

Conductor: Stranded bare copper, class 5/class 6 according to IEC 60228. Insulation: PVC Type YI 4. Inner Sheath: PVC. Screen: Tinned copper braid. Outer Sheath: PVC oil resistant Type YM 5.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Ozone Resistant Silicone Free

84

300/500 V flexing: -15℃~+80℃; fixed: -40℃~+80℃ flexing: 20×OD; fixed: 10×OD IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 25G0.75 3G1 4G1 5G1 7G1 12G1 18G1 25G1 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 47G1.5 3G2.5 4G2.5 5G2.5 G: with yellow/green earth core

Nominal Overall Diameter mm 8.6 9.5 10.0 11.9 14.7 19.5 9.3 9.9 11.0 12.6 15.1 17.9 21.7 10.1 11.1 12.5 14.5 17.6 21.2 24.7 32.0 11.6 12.9 14.4

Nominal Weight kg/km 108 123 147 189 296 529 130 150 191 223 322 455 668 146 179 221 303 448 637 845 1480 207 247 309

×: without yellow/green earth core

www.caledonian-cables.co.uk www.addison-cables.com

85


Caledonian Windmill Cables

Control Cable Halogen Free Grounding Cable 0.6/1 kV »» Application These cables with reduced fire hazard and higher safety performance are designed for control and power systems, used as connecting cable for earthing or grounding of trays, cubicle and other conductive parts.

»» Standards DIN VDE 0295

»» Construction Stranded Copper Conductor Halogen Free Insulation

Conductor: Stranded bare copper, class 5/class 2 according to IEC 60228. Insulation: Halogen free compound HM4 according to IEC 60092-353.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Smoke Density Ozone Resistant Silicone Free

86

0.6/1kV flexing: -5℃~+85℃; fixed: -35℃~+85℃ flexing: 16×OD; fixed: 8×OD IEC 60332-3 Cat. A IEC 60754 IEC 60754 IEC 61034 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 1G1.5 1G2.5 1G4 1G6 1G16 1G25 1G35 1G50 1G70 1G95 1G120 1G6 1G10 1G16 1G25 1G70

Nominal Overall Diameter mm Class 2 Stranded 2.9 3.3 3.8 4.4 6.2 7.9 8.9 10.3 12.2 14.0 15.8 Class 5 Stranded 4.4 5.4 6.6 8.4 12.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 20 31 46 68 169 264 364 516 720 967 1220 68 109 170 266 728

87


Caledonian Windmill Cables

Control Cable Y 300/500V »» Application These cables are designed for flexible use for mechanical stresses as measuring, control and regulating cables in tool machines, conveyor belts, and production lines in machinery production, in air-conditioning and in steel production, suitable for dry, moist and wet rooms.

»» Standards DIN VDE 0245

»» Construction

Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC Type YI 2. Sheath: PVC Type YM 2/TM 2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Ozone Resistant Silicone Free Lead Free

88

300/500V flexing: -15℃~+70℃; fixed: -40℃~+70℃ flexing: 20×OD; fixed: 10×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 4G0.5 5G0.5 6G0.5 7G0.5 8G0.5 10G0.5 12G0.5 16G0.5 18G0.5 21G0.5 25G0.5 30G0.5 34G0.5 40G0.5 42G0.5 50G0.5 65G0.5 80G0.5 100G0.5 2×0.75 3×0.75 3G0.75 4G0.75 5G0.75 6G0.75 7G0.75 8G0.75 9G0.75 10G0.75 12G0.75 14G0.75 15G0.75 16G0.75 18G0.75 21G0.75 25G0.75

Nominal Overall Diameter mm 4.7 5.1 5.4 6.2 7.2 6.6 7.0 8.4 8.6 10.1 10.1 11.4 12.5 13.2 13.8 14.8 15.4 17.4 19.4 21.2 23.4 5.1 5.4 5.4 5.9 6.7 6.9 7.1 7.4 8.1 9.1 9.4 9.9 10.6 10.8 11.1 12.4 13.4 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 32 39 46 57 64 70 77 97 110 148 160 188 219 264 283 333 353 441 556 680 844 39 50 50 60 72 81 90 100 128 124 146 166 182 215 211 254 289 89


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 32G0.75 34G0.75 41G0.75 42G0.75 50G0.75 61G0.75 65G0.75 80G0.75 100G0.75 2×1 3×1 3G1 4×1 4G1 5G1 6G1 7G1 8G1 9G1 10G1 12G1 14G1 15G1 16G1 18G1 21G1 25G1 34G1 41G1 42G1 50G1 61G1 65G1 80G1 100G1 2×1.5 3×1.5 3G1.5 4×1.5 4G1.5 5G1.5

90

Nominal Overall Diameter mm 14.9 15.1 16.0 16.0 18.1 19.8 20.7 22.1 24.6 5.3 5.8 5.6 6.1 6.5 6.7 7.0 7.5 8.0 9.9 9.9 9.9 10.6 11.1 11.1 11.7 13.1 14.3 16.3 17.7 17.9 19.1 20.5 21.5 24.3 27.5 6.2 6.7 6.5 7.2 7.4 7.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 380 378 452 461 559 673 774 879 1084 49 57 60 69 69 83 101 104 120 161 161 174 202 215 226 252 305 346 477 566 578 682 883 949 1092 1398 61 78 79 97 92 109


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 6G1.5 7G1.5 8G1.5 9G1.5 10G1.5 12G1.5 14G1.5 16G1.5 18G1.5 21G1.5 25G1.5 32G1.5 34G1.5 42G1.5 50G1.5 61G1.5 65G1.5 80G1.5 100G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 8G2.5 12G2.5 18G2.5 25G2.5 34G2.5 50G2.5 3G4 4G4 5G4 7G4 3G6 4G6 5G6 7G6 3G10 4G10 5G10

Nominal Overall Diameter mm 8.6 9.0 9.5 10.5 11.3 11.6 12.0 12.9 13.7 14.9 16.9 18.1 18.8 20.5 22.2 23.7 24.7 28.3 30.1 7.3 7.7 8.5 9.7 10.1 11.3 13.9 17.1 20.7 21.7 28.7 9.3 10.2 11.6 12.8 11.0 12.3 13.5 14.9 14.0 15.0 17.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 133 147 169 185 210 237 271 310 347 403 490 606 642 798 926 1119 1020 1545 1808 92 119 148 180 232 274 377 575 786 1080 1566 176 219 269 356 255 323 391 519 411 513 650

91


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 7G10 3G16 4G16 5G16 7G16 4G25 5G25 7G25 4G35 5G35 7G35 4G50 5G50 4G70 5G70 4G95 5G95 4G120 4G150 4G185 G: with green-yellow earth core

Nominal Overall Diameter mm 18.8 18.2 19.2 21.3 23.8 23.0 25.8 28.5 26.7 29.5 38.0 31.5 34.7 35.7 40.0 41.1 45.6 45.1 62.3 67.0

×: without green-yellow earth core

92

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 844 653 844 1012 1367 1252 1548 2078 1658 2029 3156 2360 2920 3201 4011 4259 5292 5263 8340 9904


Caledonian Windmill Cables

Control Cable CY 300/500V »» Application These screened cables are designed for use as a data cable in control circuits, in tool-making and machine industries as well as a signal cable in computer systems and electronics. PVC inner sheath has been replaced in these cables by a stabilising foil separator, thus reducing the total diameter of the cables considerably and thereby reducing the bending radius, total weight etc..

»» Standards DIN VDE 0245

»» Construction Stranded Copper Conductor PVC Insulation Al Coated Tape Tinned Copper Braid PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC Type YI 2. Separator: Al coated tape. Screen: Tinned copper braid. Sheath: PVC Type YM 2/TM 2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Ozone Resistant Silicone Free Lead Free

300/500V flexing: -15℃~+70℃; fixed: -40℃~+70℃ flexing: 20×OD; fixed: 10×OD IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

93


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of coresGmm² 2×0.5 3G0.5 4G0.5 5G0.5 6G0.5 7G0.5 8G0.5 12G0.5 18G0.5 25G0.5 2G0.75 3G0.75 4G0.75 5G0.75 6G0.75 7G0.75 8G0.75 12G0.75 18G0.75 25G0.75 34G0.75 50G0.75 2×1 3G1 4G1 5G1 6G1 7G1 8G1 12G1 18G1 25G1 34G1 50G1 2×1.5 3G1.5 4G1.5 5G1.5 94

Nominal Overall Diameter mm 5.4 5.8 6.3 6.7 7.2 7.3 7.7 9.2 10.2 13.3 6.0 6.3 6.8 7.3 7.8 7.8 8.3 10.1 11.6 13.9 15.6 19.0 6.2 6.5 7.0 7.6 8.2 8.4 9.0 10.4 12.4 14.9 16.6 19.6 6.8 7.2 7.8 8.4 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 45 53 63 76 87 107 109 140 179 256 54 65 77 91 102 115 137 177 250 326 406 576 60 73 89 105 110 139 157 207 295 384 530 1020 70 90 108 125


Caledonian Windmill Cables

Control Cable Construction No. of coresGmm² 7G1.5 8G1.5 12G1.5 18G1.5 25G1.5 34G1.5 42G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 2×4 4G4 5G4 7G4 2×6 3G6 4G6 5G6 7G6 2×10 3G10 4G10 5G10 7G10 4G16 5G16 4G25 5G25 4G35 5G35 4G50 G: with green-yellow earth core

Nominal Overall Diameter mm 9.3 10.0 11.8 14.0 16.9 18.9 20.1 8.0 8.6 9.4 10.0 10.8 14.6 9.8 11.1 12.1 14.0 11.7 12.5 12.8 14.2 16.9 14.7 15.7 17.3 19.2 21.4 20.8 22.6 24.9 27.8 28.4 31.6 34.6

Nominal Weight kg/km 160 204 279 350 530 720 820 104 140 173 206 267 432 185 236 288 500 268 330 339 416 672 425 500 783 856 1305 880 1295 1570 1965 2070 2690 3015

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

95


Caledonian Windmill Cables

Control Cable YCY 300/500V »» Application These screened cables are designed for use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics.

»» Standards DIN VDE 0245

»» Construction Stranded Copper Conductor PVC Insulation PVC Inner Sheath Tinned Copper Braid PVC Outer Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC Type YI 2. Inner Sheath: PVC. Screen: Tinned copper braid. Outer Sheath: PVC Type YM 2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Ozone Resistant Silicone Free Lead Free

96

300/500V flexing: -15℃~+70℃; fixed: -40℃~+70℃ flexing: 20×OD; fixed: 10×OD IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of coresGmm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 12G0.5 18G0.5 2×0.75 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 2×1 3G1 4G1 5G1 7G1 12G1 18G1 25G1 34G1 41G1 50G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 3G2.5 4G2.5 5G2.5 7G2.5

Nominal Overall Diameter mm 5.6 6.6 7.6 8.3 9.3 11.0 12.0 7.1 7.4 7.9 8.4 9.0 11.2 12.7 16.0 7.3 7.6 8.1 8.7 9.3 11.7 13.5 16.6 19.5 20.4 22.9 7.9 8.3 9.1 9.7 10.2 13.3 16.4 18.6 9.5 10.3 11.5 12.3 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 65 72 77 90 114 160 216 71 82 94 109 122 192 261 388 78 90 106 121 144 225 315 455 657 698 918 94 112 133 148 183 295 451 599 158 191 213 274 97


Caledonian Windmill Cables

Control Cable Construction No. of coresGmm² 12G2.5 3G4 4G4 5G4 4G6 5G6 4G10 5G10 4G16 5G16 4G25 5G25 4G35 5G35 4G50 5G50 4G70 5G70 4G95 5G95 4G120 5G120 4G150 5G150 G: with green-yellow earth core

Nominal Overall Diameter mm 13.3 10.7 12.2 12.7 14.0 16.4 17.9 19.4 21.5 23.2 25.2 28.2 29.9 32.0 34.4 43.0 46.8 51.8 51.0 56.0 56.0 63.0 63.5 69.5

×: without green-yellow earth core

98

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 530 218 274 317 378 493 636 760 953 1130 1401 1935 1886 2268 2674 4150 4600 5750 6060 7580 7315 9150 9680 10170


Caledonian Windmill Cables

Control Cable Halogen Free Control Cable 300/500 V »» Application These halogen-free, flame retardant cables are designed for use as measuring and control cable in machinery and plant construction, in building and air-conditioning systems, in warehousing and conveying systems, in ship-building and for renewable energy such as in the construction of wind turbines.

»» Standards DIN VDE 0281 part 14

»» Construction Stranded Copper Conductor Halogen Free Insulation Halogen Free Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC 60228. Insulation: Halogen-free compound special polymer. Sheath: Halogen-free compound special polymer.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Smoke Density Oil Resistant Ozone Resistant

300/500V flexing: -30℃~+90℃; fixed: -40℃~+90℃ flexing: 10×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 NF X 10-702 VDE 0482 part 1034-1+2/IEC 61034-1+2/DIN EN 61034-1+2/BS 7622 part 1+2 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

99


Caledonian Windmill Cables

Control Cable Silicone Free UV Resistant

Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 3×0.5 4G0.5 4×0.5 5G0.5 5×0.5 7G0.5 8G0.5 10G0.5 12G0.5 16G0.5 18G0.5 20G0.5 25G0.5 30G0.5 34G0.5 37G0.5 41G0.5 42G0.5 50G0.5 61G0.5 65G0.5 2×0.75 3G0.75 3×0.75 4G0.75 4×0.75 5G0.75 5×0.75 7G0.75 7×0.75 8G0.75 10G0.75 12G0.75

100

Nominal Overall Diameter mm 4.8 5.1 5.1 5.7 5.7 6.2 6.2 7.4 8.0 8.8 9.1 10.0 10.7 11.2 12.7 13.5 14.5 15.0 15.8 15.8 17.3 19.4 19.4 5.2 5.5 5.5 6.2 6.2 6.8 6.8 8.1 8.1 8.9 9.6 9.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 43 50 50 60 60 71 71 84 101 121 142 183 204 227 283 324 367 381 417 454 519 635 694 47 56 56 69 69 83 83 114 114 136 172 183


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 16G0.75 18G0.75 20G0.75 25G0.75 30G0.75 34G0.75 37G0.75 41G0.75 42G0.75 50G0.75 61G0.75 65G0.75 2×1 3G1 3×1 4G1 4×1 5G1 7G1 8G1 10G1 12G1 16G1 18G1 20G1 25G1 34G1 37G1 41G1 42G1 50G1 61G1 65G1 2×1.5 3G1.5 3×1.5 4G1.5 5G1.5 7G1.5 8G1.5 10G1.5

Nominal Overall Diameter mm 11.5 11.9 12.6 14.1 15.4 16.4 17.2 17.6 17.6 19.8 20.9 21.5 5.5 6.0 6.0 6.6 6.6 7.2 8.6 9.4 10.4 10.7 12.0 12.7 13.5 15.2 17.4 18.4 18.9 18.9 21.0 22.2 22.8 6.3 6.7 6.7 7.3 8.2 9.8 10.6 11.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 241 266 291 374 450 517 541 611 621 742 853 909 63 74 74 90 90 109 151 184 224 243 314 361 387 496 670 713 784 824 952 1140 1201 70 94 94 112 141 191 224 282

101


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 12G1.5 16G1.5 18G1.5 20G1.5 25G1.5 34G1.5 37G1.5 50G1.5 61G1.5 65G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 8G2.5 10G2.5 12G2.5 16G2.5 18G2.5 20G2.5 25G2.5 30G2.5 2×4 3G4 4G4 5G4 7G4 8G4 10G4 12G4 16G4 18G4 2×6 3G6 4G6 5G6 7G6 2×10 3G10 4G10

102

Nominal Overall Diameter mm 12.1 13.6 14.5 15.2 17.8 19.8 20.2 23.7 25.3 26.0 7.6 8.3 9.1 10.2 12.1 13.2 14.7 15.2 17.5 18.1 18.7 22.2 23.7 9.2 9.9 11.0 12.1 13.3 15.9 17.3 18.3 20.2 21.8 10.8 11.7 13.0 14.5 16.0 14.0 15.0 16.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 311 392 450 497 630 842 897 1277 1460 1612 118 151 181 224 316 370 451 499 720 769 911 1047 1280 199 247 299 369 463 601 698 790 1130 1280 266 360 429 529 631 440 550 708


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 5G10 7G10 2×16 3G16 4G16 5G16 7G16 3G25 4G25 5G25 3G35 4G35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 3G120 4G120 3G150 4G150 G: with green-yellow earth core

Nominal Overall Diameter mm 18.7 20.6 16.5 17.6 19.7 21.9 24.4 22.5 25.2 27.9 25.2 28.0 31.0 29.5 33.4 37.2 37.0 41.2 46.0 41.0 46.0 50.5 45.7 50.3 52.2 57.0

Nominal Weight kg/km 862 1124 642 830 1060 1270 1794 1190 1594 2014 1590 2200 2693 2571 3087 3980 3207 4077 5501 4708 5590 6972 5515 7100 6279 7781

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

103


Caledonian Windmill Cables

Control Cable Halogen Free, Screened Control Cable 300/500 V »» Application These screened, halogen-free, flame retardant cables are designed for use as measuring and control cable in machinery and plant construction, in building and air-conditioning systems, in warehousing and conveying systems, in ship-building and for renewable energy such as in the construction of wind turbines.

»» Standards DIN VDE 0281 part 14

»» Construction Stranded Copper Conductor Halogen Free Insulation Al Coated Tape Tinned Copper Braid Halogen Free Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC 60228. Insulation: Halogen-free compound special polymer. Separator: Al coated tape. Screen: Tinned copper braid. Sheath: Halogen-free compound special polymer.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Smoke Density

104

300/500V flexing: -30℃~+80℃; fixed: -40℃~+80℃ flexing: 10×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 NF X 10-702 VDE 0482 part 1034-1+2/IEC 61034-1+2/DIN EN 61034-1+2/BS 7622 part 1+2

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable Oil Resistant Ozone Resistant Silicone Free UV Resistant

Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 3×0.5 4G0.5 4×0.5 5G0.5 5×0.5 7G0.5 8G0.5 10G0.5 12G0.5 16G0.5 18G0.5 20G0.5 25G0.5 2×0.75 3G0.75 3×0.75 4G0.75 4×0.75 5G0.75 5×0.75 7G0.75 7×0.75 8G0.75 10G0.75 12G0.75 16G0.75 18G0.75 20G0.75 25G0.75 2×1 3G1

Nominal Overall Diameter mm 5.7 6.0 6.0 6.5 6.5 7.0 7.0 7.9 8.5 9.3 9.6 10.7 11.2 11.9 13.4 6.1 6.4 6.4 6.9 6.9 7.4 7.4 8.6 8.6 9.4 10.0 10.4 11.6 12.4 12.9 14.8 6.4 6.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 46 56 56 62 62 75 75 98 116 135 158 210 216 240 315 60 68 68 78 78 95 95 130 130 145 180 203 275 290 320 413 66 80

105


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 3×1 4G1 4×1 5G1 7G1 8G1 10G1 12G1 16G1 18G1 20G1 25G1 2×1.5 3G1.5 3×1.5 4G1.5 5G1.5 7G1.5 8G1.5 10G1.5 12G1.5 16G1.5 18G1.5 25G1.5 2×2.5 3G2.5 4G2.5 5×2.5 7G2.5 8G2.5 10G2.5 12G2.5 2×4 3G4 4G4 5G4 7G4 2×6 3G6 4G6 5G6

106

Nominal Overall Diameter mm 6.7 7.3 7.3 7.8 9.1 9.9 10.8 11.2 12.3 13.2 13.8 15.8 6.6 6.9 6.9 7.5 8.4 10.0 11.1 12.0 12.1 14.3 14.6 17.6 8.3 9.0 9.8 10.9 12.9 13.1 15.2 15.9 9.8 10.6 11.5 12.7 14.0 11.5 12.4 13.8 15.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 80 100 100 130 160 197 232 260 346 382 440 540 88 100 100 125 158 210 244 315 340 424 480 702 132 168 195 256 345 390 482 572 220 251 305 388 504 270 351 464 546


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 7G6 2×10 3G10 4G10 5G10 7G10 2×16 3G16 4G16 5G16 7G16 3G25 4G25 5G25 3G35 4×35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 3G120 4G120 4G150 G: with green-yellow earth core

Nominal Overall Diameter mm 16.6 14.9 15.9 17.8 19.6 21.6 17.2 19.0 20.8 22.9 25.0 23.5 26.2 29.7 26.0 30.4 34.1 30.3 34.6 39.1 37.9 41.3 46.4 41.5 46.2 51.5 46.8 51.0 59.2

Nominal Weight kg/km 670 461 574 785 914 1308 670 911 1105 1293 2149 1432 1911 2414 1914 2542 3180 3080 3550 4753 3840 4939 6572 5651 6690 8370 6342 8453 9104

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

107


Caledonian Windmill Cables

Control Cable Y 0.6/1kV »» Application These cables are designed for flexible use for medium mechanical stresses as measuring and control cables in tool machines, conveyor belts, production lines; for plant installations, air conditioning, in steel production plants and rolling mills, suitable for dry, moist and wet rooms as well as outside (fixed installation).

»» Standards DIN VDE 0262/12.95 DIN VDE 0281 part 13

»» Construction Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC Type TI 2/YI 2. Sheath: PVC Type TM 2/YM 2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free UV Resistant

108

600/1000V flexing: -5℃~+80℃; fixed: -40℃~+80℃ flexing: 7.5×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 3×0.5 4G0.5 4×0.5 5G0.5 5×0.5 6G0.5 7G0.5 7×0.5 8G0.5 8×0.5 10G0.5 12G0.5 12×0.5 14G0.5 16G0.5 18G0.5 20G0.5 21G0.5 25G0.5 30G0.5 32G0.5 34G0.5 40G0.5 42G0.5 50G0.5 52G0.5 61G0.5 65G0.5 80G0.5 100G0.5 2×0.75 3G0.75 3×0.75 4G0.75 4×0.75 5G0.75

Nominal Overall Diameter mm 6.3 6.7 6.7 7.2 7.2 8.0 8.0 8.9 8.9 8.9 10.2 10.2 11.2 11.4 11.4 12.3 12.9 13.8 14.4 14.4 16.4 17.2 18.0 18.7 20.2 20.2 22.1 22.1 23.6 25.0 27.2 30.2 6.6 7.0 7.0 7.6 7.6 8.4 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 56 68 68 100 100 117 117 126 138 138 150 150 176 200 200 230 250 276 293 305 335 348 355 520 590 595 715 740 840 880 960 1050 66 74 74 126 126 140 109


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 5×0.75 6G0.75 6×0.75 7G0.75 7×0.75 8G0.75 8×0.75 9G0.75 10G0.75 12G0.75 12×0.75 14G0.75 15G0.75 18G0.75 20G0.75 21G0.75 25G0.75 32G0.75 34G0.75 37G0.75 40G0.75 41G0.75 42G0.75 50G0.75 61G0.75 65G0.75 80G0.75 100G0.75 2×1 3G1 3×1 4G1 4×1 5G1 5×1 6G1 7G1 7×1 8G1 9G1 10G1

110

Nominal Overall Diameter mm 8.4 9.3 9.3 9.3 9.3 10.9 10.9 11.8 11.8 12.3 12.3 12.9 13.8 14.5 15.4 16.1 17.4 19.1 19.9 19.9 21.5 21.5 21.5 23.5 25.3 26.9 28.9 32.1 7.0 7.3 7.3 8.2 8.2 9.2 9.2 9.9 9.9 9.9 11.6 12.8 12.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 140 170 170 190 190 212 212 227 238 257 257 286 319 362 394 422 486 595 638 696 726 750 770 895 1070 1110 1500 1889 80 96 96 100 100 130 130 150 170 170 230 250 270


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 10×1 12G1 12×1 14G1 16G1 18G1 18×1 20G1 21G1 24G1 25G1 25×1 26G1 30×1 34G1 36G1 40G1 40×1 41G1 42G1 50G1 56G1 61G1 65G1 80G1 100G1 3G16 2×1.5 3G1.5 3×1.5 4G1.5 4×1.5 5G1.5 5×1.5 6G1.5 7G1.5 7×1.5 8G1.5 9G1.5 10G1.5 11G1.5

Nominal Overall Diameter mm 12.8 13.0 13.0 14.0 14.8 15.7 15.7 16.7 17.4 18.4 18.8 18.8 18.8 19.9 21.5 21.5 23.2 23.2 23.2 23.2 25.6 26.4 27.3 29.0 31.4 34.8 20.5 8.2 8.6 8.6 9.6 9.6 10.7 10.7 11.6 11.6 11.6 13.8 15.2 15.2 15.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 270 290 290 320 360 405 405 450 510 550 570 570 590 650 750 790 850 850 890 900 1100 1190 1266 1560 1810 1950 700 95 112 112 139 139 170 170 190 225 225 250 280 300 330

111


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 12G1.5 12×1.5 14G1.5 16G1.5 18G1.5 19G1.5 20G1.5 21G1.5 25G1.5 32G1.5 34G1.5 40G1.5 42G1.5 50G1.5 56G1.5 61G1.5 65G1.5 80G1.5 100G1.5 2×2.5 3G2.5 3×2.5 4G2.5 4×2.5 5G2.5 5×2.5 7G2.5 7×2.5 8G2.5 12G2.5 14G2.5 18G2.5 21G2.5 25G2.5 34G2.5 42G2.5 50G2.5 61G2.5 100G2.5 2×4 3G4

112

Nominal Overall Diameter mm 15.5 15.5 16.6 17.5 18.6 18.6 19.7 20.6 22.5 24.5 25.6 27.6 27.6 30.4 31.5 32.6 34.8 37.4 41.6 9.4 10.1 10.1 11.2 11.2 12.5 12.5 13.8 13.8 16.1 18.3 19.4 22.0 25.0 26.7 30.4 33.0 36.2 38.8 49.5 11.4 12.3

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 370 370 400 450 520 550 600 600 730 880 950 990 1120 1400 1530 1700 1900 2300 2700 160 175 175 203 203 251 251 330 330 400 553 630 795 930 1110 1450 1750 2100 2540 3850 180 230


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 4G4 5G4 7G4 8G4 12G4 3G6 4G6 5G6 7G6 3G10 4G10 5G10 7G10 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 3G35 4G35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 4G120 4G150 4G185 G: with green-yellow earth core

Nominal Overall Diameter mm 13.7 15.2 16.7 19.9 22.6 14.0 15.5 17.3 19.2 16.4 18.2 20.4 22.4 20.5 22.6 25.4 27.8 24.8 27.6 30.3 33.6 27.5 30.5 34.1 33.5 37.2 41.8 38.7 42.7 47.6 43.3 48.0 52.8 52.6 61.3 67.1

Nominal Weight kg/km 310 410 540 710 860 370 430 650 860 660 790 960 1300 700 1100 1600 1890 1450 1600 2050 2900 1900 2400 2900 2700 3400 4361 3300 4400 5807 5050 6010 7752 7500 8640 10380

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

113


Caledonian Windmill Cables

Control Cable YCY 0.6/1kV »» Application These screened cables are designed for flexible use for medium mechanical stresses as measuring and control cables in tool machines, conveyor belts, production lines; for plant installations, air conditioning, in steel production plants and rolling mills, suitable for dry, moist and wet rooms as well as outside (fixed installation).

»» Standards DIN VDE 0262/12.95 DIN VDE 0281 part 13

»» Construction Stranded Copper Conductor PVC Insulation PVC Inner Sheath Tinned Copper Braid PVC Outer Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC Type TI 2 Inner Sheath: PVC. Screen: Tinned copper braid. Outer Sheath: PVC Type TM 2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free UV Resistant 114

600/1000V flexing: -5℃~+80℃; fixed: -40℃~+90℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of coresGmm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 12G0.5 18G0.5 25G0.5 2×0.75 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 2×1 3G1 4G1 5G1 7G1 12G1 18G1 25G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 18G2.5 25G2.5

Nominal Overall Diameter mm 8.5 8.8 9.6 10.2 11.1 14.0 16.2 19.2 8.8 9.3 9.9 10.8 11.5 14.6 17.1 20.3 9.4 9.8 10.4 11.4 12.5 15.7 18.4 21.8 10.4 11.1 11.8 13.1 14.2 18.4 21.5 25.6 11.8 12.7 13.8 15.1 16.3 21.3 25.4 30.0 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 129 150 170 199 235 320 428 503 143 155 190 228 323 410 560 730 150 163 200 239 289 464 628 855 162 187 240 289 383 592 806 1241 272 298 345 427 561 857 1355 1995 115


Caledonian Windmill Cables

Control Cable Construction No. of coresGmm² 2×4 3G4 4G4 5G4 7G4 12G4 2×6 3G6 4G6 5G6 7G6 2×10 3G10 4G10 5G10 7G10 2×16 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 3G35 4G35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 3G120 4G120 4G150 4G185 G: with green-yellow earth core

Nominal Overall Diameter mm 14.2 15.1 16.2 18.0 19.8 25.8 15.9 16.9 18.7 20.4 22.2 18.3 19.2 21.2 23.2 26.8 22.8 24.7 27.0 30.0 32.2 29.2 32.0 35.7 39.0 32.3 35.8 39.5 39.7 43.4 47.8 44.9 49.1 53.8 49.6 54.1 57.7 51.5 59.4 67.9 74.0

×: without green-yellow earth core

116

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 306 391 527 700 920 1510 420 629 731 1105 1465 845 1125 1345 1635 2210 1150 1395 1870 2720 3213 2465 2750 3490 4980 3230 4100 4950 4590 5780 7210 5610 7480 9390 8585 10220 13800 11105 13750 15990 18470


Caledonian Windmill Cables

Control Cable Halogen Free Control Cable 0.6/1 kV »» Application These halogen-free, flame retardant cables are designed for use as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant installations, in air-conditioning and steel production works, suitable for the application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in direct laying in vibration, compacted or compressed concrete.

»» Standards DIN VDE 0281 part 14 DIN VDE 0281 part 13 IEC 60092-351

»» Construction Stranded Copper Conductor Halogen Free Insulation Halogen Free Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC 60228. Insulation: Halogen-free compound TI6/XLPE compound Type HF Sheath: Halogen-free sheath compound TM7/HM4.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Smoke Density

600/1000V flexing: -15℃~+70℃; fixed: -40℃~+70℃ 15×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754 VDE 0482 part 1034-1+2/IEC 61034-1+2/DIN EN 61034-1+2/BS 7622 part 1+2

www.caledonian-cables.co.uk www.addison-cables.com

117


Caledonian Windmill Cables

Control Cable Oil Resistant Silicone Free

Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 3×0.5 4G0.5 4×0.5 5G0.5 5×0.5 7G0.5 10G0.5 12G0.5 18G0.5 25G0.5 2×0.75 3G0.75 3×0.75 4G0.75 4×0.75 5G0.75 5×0.75 7G0.75 10G0.75 12G0.75 18G0.75 25G0.75 2×1 3G1 3×1 4G1 4×1 5G1 5×1 7G1 10G1 12G1 18G1 25G1 2×1.5 3G1.5 3×1.5

118

Nominal Overall Diameter mm 6.4 6.8 6.8 7.6 7.6 8.2 8.2 9.8 11.6 12.2 14.4 17.2 6.8 7.2 7.2 8.0 8.0 8.8 8.8 10.7 12.7 13.1 15.6 18.9 7.4 8.0 8.0 8.8 8.8 9.8 9.8 11.7 14.1 14.5 17.3 21.1 8.4 9.1 9.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 57 69 69 104 104 121 121 145 186 224 292 357 68 77 77 136 136 152 152 208 250 271 387 498 82 99 99 140 140 160 160 217 271 301 417 576 97 119 119


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 4G1.5 4×1.5 5G1.5 5×1.5 7G1.5 10G1.5 12G1.5 18G1.5 25G1.5 2×2.5 3G2.5 3×2.5 4G2.5 4×2.5 5G2.5 5×2.5 7G2.5 10G2.5 12G2.5 18G2.5 25G2.5 3G4 4G4 5G4 3G6 4G6 5G6 3G10 4G10 5G10 3G16 4G16 5G16 3G25 4G25 5G25 3G35 4G35 5G35 4G50 4G70 4G95 4G120 G: with green-yellow earth core

Nominal Overall Diameter mm 9.9 9.9 11.0 11.0 13.3 15.9 16.6 19.7 23.9 9.4 9.9 9.9 11.1 11.1 12.4 12.4 15.0 18.4 22.0 24.6 26.9 12.3 13.8 15.3 14.1 15.6 17.3 16.5 18.4 20.5 19.1 21.2 23.6 24.0 26.9 29.3 26.2 29.4 32.8 34.2 41.0 46.2 50.3

Nominal Weight kg/km 148 148 172 172 243 311 392 529 741 160 177 177 209 209 272 272 340 561 799 940 1121 255 319 423 380 441 657 668 796 972 832 1122 1604 1457 1611 2070 1914 2424 2970 3467 4491 6170 7618

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

119


Caledonian Windmill Cables

Control Cable Halogen Free, Screened Control Cable 0.6/1 kV »» Application These screened, halogen-free, flame retardant cables are designed for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works, suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry and concrete walls except for direct embedding in vibrated, compacted or tamped concrete.

»» Standards DIN VDE 0281 part 14 DIN VDE 0281 part 13

»» Construction Stranded Copper Conductor Halogen Free Insulation Halogen Free Inner Sheath Tinned Copper Braid Halogen Free Outer Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC 60228. Insulation: Halogen-free compound TI6. Inner Sheath: Halogen-free compound. Screen: Tinned copper braid. Outer Sheath: Halogen-free compound TM7.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant

120

600/1000V flexing: -5℃~+70℃; fixed: -40℃~+70℃ 15×OD DIN VDE 0482 Part 265-2-1/ EN 50265-2-1/IEC 60332-1

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable Halogen Free Gases Corrosively Smoke Density Oil Resistant Silicone Free

VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754 VDE 0482 part 1034-1+2/IEC 61034-1+2/DIN EN 61034-1+2/BS 7622 part 1+2 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 3G0.5 4G0.5 5G0.5 7G0.5 12G0.5 18G0.5 25G0.5 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 3G1 4G1 5G1 7G1 12G1 18G1 25G1 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 3G2.5 4G2.5 5G2.5

Nominal Overall Diameter mm 8.6 9.4 10.1 12.1 14.7 17.3 20.6 9.0 9.9 10.8 13.0 15.8 17.9 22.8 9.8 10.8 12.1 14.5 17.4 20.7 24.8 10.9 12.2 13.3 16.0 19.6 23.4 28.2 12.2 13.4 14.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 150 170 199 235 320 428 503 155 190 228 323 410 560 730 163 200 239 289 464 628 855 187 240 289 383 592 806 1241 298 345 427

121


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 7G2.5 12G2.5 18G2.5 25G2.5 3G4 4G4 5G4 3G6 4G6 5G6 3G10 4G10 5G10 4G16 5G16 7G16 3G25 4G25 5G25 3G35 4G35 5G35 4G50 4G70 4G95 4G120 4G150 G: with green-yellow earth core

Nominal Overall Diameter mm 17.9 21.9 26.1 31.9 15.1 16.7 18.6 17.0 18.7 20.7 19.6 21.9 24.1 23.5 26.4 28.8 28.0 32.5 35.7 32.7 35.7 40.0 41.1 48.0 51.2 56.0 64.5

×: without green-yellow earth core

122

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 561 857 1355 1995 391 527 700 629 731 1105 1125 1345 1635 1395 1870 2720 2465 2750 3490 3230 4100 4950 5780 7480 10220 13750 15900


Caledonian Windmill Cables

Control Cable Halogen Free, Screened Control Cable 0.6/1 kV 90°C »» Application These halogen-free, flame retardant cables are designed for frequency converter controlled AC drives, suitable for xed installation and occasional free exing indoors in dry, damp and wet conditions, as well as outdoors for low mechanical stress.

»» Standards DIN VDE 0250 IEC 60092-353

»» Construction Stranded Copper Conductor Halogen Free XLPE Insulation Aluminium/Polyester Tape Tinned Copper Braid Halogen Free Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC 60228. Protective Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC 60228. For cross sections > 16mm² the protective conductor is divided into 3 cores. Insulation: Halogen free special XLPE according to IEC 60502-4. Screen: Al coated tape + tinned copper wires braid. Sheath: Halogen free compound HM4. Halogen free PUR can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Ozone Resistant UV Resistant

600/1000V -5℃~+90℃ flexing: 20×OD; fixed: 10×OD IEC 60332-3 IEC 60754 IEC 60754 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

123


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 4×1.5 4×2.5 4×4 4×6 4×10 3×16+3×2.5 3×25+3×4 3×35+3×6 3×50+3×10 3×70+3×10 3×95+3×16 3×120+3×16 3×150+3×25 3×185+3×35 3×240+3×50 3×300+3×50

124

Nominal Overall Diameter mm 11.0 12.5 15.5 17.5 19.5 22.5 26.0 29.5 35.0 38.5 44.0 48.0 53.0 58.0 66.0 73.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 230 300 390 420 780 820 1150 1550 2400 3100 4200 4630 5880 7200 9600 11530


Caledonian Windmill Cables

Control Cable Y 0.6/1kV UL/CSA »» Application These cables are designed for flexible use for medium mechanical stresses as measuring and control cables in tool machines, conveyor belts, production lines; for plant installations, air conditioning, in steel production plants and rolling mills, suitable for dry, moist and wet rooms as well as outside (fixed installation).

»» Standards VDE 0276 part 627 DIN VDE 0281 part 13 UL 758 IEC 60502

»» Construction Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: Special PVC type TI2 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581. Sheath: Special PVC.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free UV Resistant

600/1000V flexing: -5℃~+80℃; fixed: -40℃~+80℃ flexing: 7.5×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1/VW1/FT1 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

125


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 12G0.5 18G0.5 25G0.5 2×0.75 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 2×1 3G1 4G1 5G1 7G1 12G1 18G1 25G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 126

Nominal Overall Diameter mm 6.4 6.8 7.6 8.2 9.8 12.2 14.4 17.2 6.8 7.2 8.0 8.8 10.7 13.1 15.6 18.9 7.4 8.0 8.8 9.8 11.7 14.5 17.3 21.1 8.4 9.1 9.9 11.0 13.3 16.6 19.7 23.9 9.4 9.9 11.1 12.4 15.0 18.4 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 56 68 100 117 138 200 276 335 66 74 126 140 190 257 362 486 80 96 100 130 170 290 405 570 95 112 139 170 225 370 520 730 160 175 203 251 330 553


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 18G2.5 25G2.5 2×4 3G4 4G4 5G4 7G4 12G4 3G6 4G6 5G6 7G6 3G10 4G10 5G10 7G10 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 G: with green-yellow earth core

Nominal Overall Diameter mm 22.0 26.9 11.4 12.3 13.8 15.3 16.8 22.9 14.1 15.6 17.3 19.3 16.5 18.4 20.5 22.5 19.6 21.7 24.2 25.7 24.0 26.9 29.3 32.6

Nominal Weight kg/km 795 1110 180 230 310 410 540 860 370 430 650 860 660 790 960 1300 760 1100 1600 1890 1450 1600 2050 2900

×: without green-yellow earth core

www.caledonian-cables.co.uk www.addison-cables.com

127


Caledonian Windmill Cables

Control Cable YCY 0.6/1kV UL/CSA »» Application These screened cables are designed for flexible use for medium mechanical stresses as measuring and control cables in tool machines, conveyor belts, production lines; for plant installations, air conditioning, in steel production plants and rolling mills, suitable for dry, moist and wet rooms as well as outside (fixed installation) .

»» Standards VDE 0276 part 627 DIN VDE 0281 part 13 UL 758 IEC 60502

»» Construction Stranded Copper Conductor PVC Insulation PVC Inner Sheath Tinned Copper Braid PVC Outer Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC type TI2 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581. Inner Sheath: PVC type TM 2 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581. Screen: Tinned copper braid. Outer Sheath: PVC type TM 2 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant

128

600/1000V flexing: -5℃~+80℃; fixed: -40℃~+90℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1/VW 1/FT1

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable Oil Resistant Silicone Free UV Resistant

Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 12G0.5 18G0.5 25G0.5 2×0.75 3G0.75 4G0.75 5G0.75 7G0.75 12G0.75 18G0.75 25G0.75 2×1 3G1 4G1 5G1 7G1 12G1 18G1 25G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 18G1.5 25G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5

Nominal Overall Diameter mm 8.3 8.6 9.4 10.1 12.1 14.7 17.3 20.6 8.7 9.0 9.9 10.8 13.0 15.8 17.9 22.8 9.4 9.8 10.8 12.1 14.5 17.4 20.7 24.8 10.2 10.9 12.2 13.3 16.0 19.6 23.4 28.2 11.5 12.2 13.4 14.9 17.9 21.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 129 150 170 199 235 320 428 503 143 155 190 228 323 410 560 730 150 163 200 239 289 464 628 855 162 187 240 289 383 592 806 1241 272 298 345 427 561 857

129


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 18G2.5 25G2.5 2×4 3G4 4G4 5G4 7G4 3G6 4G6 5G6 7G6 3G10 4G10 5G10 7G10 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 G: with green-yellow earth core

Nominal Overall Diameter mm 26.1 31.9 14.3 15.1 16.7 18.6 20.0 17.0 18.7 20.7 23.0 19.6 21.9 24.1 26.8 23.5 26.4 28.8 31.9 28.0 32.5 35.7 39.0

×: without green-yellow earth core

130

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 1355 1995 306 391 527 700 920 629 731 1105 1465 1125 1345 1635 2210 1395 1870 2720 3213 2465 2750 3490 4980


Caledonian Windmill Cables

Control Cable Y UL/CSA 600V 90°C »» Application These flexible control cable rated at 600V are used in machine tools, control systems, connection between control panels and machines, assembly lines and other industrial equipment, suitable for installation in dry, moist or wet environment and moderate flexing applications.

»» Standards UL AWM I/II A/B Style 2587 CSA

»» Construction Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC60228. Insulation: PVC Type TI3 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581. PVC TI1 can be offered upon request. Sheath: PVC Type YM5 according to DIN VDE 0207 part 5, class 43 UL-Std. 1581. PVC TM5 can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

600V flexing: -5℃~+90℃; fixed: -40℃~+90℃ flexing: 7.5×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

131


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 8G0.5 9G0.5 12G0.5 18G0.5 25G0.5 34G0.5 41G0.5 2×1 3×(G)1 4G1 5G1 7G1 8G1 9G1 12G1 18G1 25G1 34G1 41G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 9G1.5 12G1.5 18G1.5 25G1.5 34G1.5 41G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 132

Nominal Overall Diameter mm 5.9 6.3 6.7 7.3 8.5 9.6 10.4 10.9 12.9 15.5 17.7 19.9 6.3 6.7 7.3 7.9 9.2 10.0 11.1 11.8 14.1 17.1 19.3 21.2 6.9 7.5 8.1 8.7 10.6 12.8 13.4 15.8 18.9 21.7 23.7 8.2 8.7 10.1 10.9 13.1 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 49 58 69 84 123 140 177 192 256 358 487 580 53 61 74 90 130 144 180 198 274 384 494 508 73 94 117 140 186 244 319 451 625 840 1032 115 143 185 221 293


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 9G2.5 12G2.5 18G2.5 19G2.5 25G2.5 3G4 4G4 5G4 7G4 3G6 4G6 5G6 7G6 3G10 4G10 5G10 7G10 2×16 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 3G35 4G35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 3G120 4G120 5G120 G: with green-yellow earth core

Nominal Overall Diameter mm 15.6 16.7 19.6 19.7 24.0 11.2 12.5 13.8 16.3 12.9 14.2 15.9 19.4 16.9 18.5 20.3 22.3 19.4 20.7 23.2 25.7 28.4 25.0 28.1 30.9 35.5 28.6 31.7 35.2 31.2 35.8 38.7 39.2 41.6 48.4 42.1 46.0 51.2 47.8 52.8 59.0

Nominal Weight kg/km 429 563 854 914 1188 232 298 358 460 360 402 484 630 535 653 786 1100 640 810 1045 1260 1760 1180 1507 1858 2830 1590 2123 2612 2652 3058 4093 3307 4254 5661 4867 5762 7208 5580 7280 8692

×: without green-yellow earth core.

www.caledonian-cables.co.uk www.addison-cables.com

133


Caledonian Windmill Cables

Control Cable YCY UL/CSA 600V 90°C »» Application These flexible control cable rated at 600V are used in machine tools, control systems, connection between control panels and machines, assembly lines and other industrial equipment, suitable for installation in dry, moist or wet environment and moderate flexing applications.

»» Standards UL Style 10012 Style 2587 CSA

»» Construction Stranded Copper Conductor PVC Insulation PVC Inner Sheath Tinned Copper Braid PVC Outer Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/BS 6360/IEC60228. Insulation: PVC Type TI3 according to DIN VDE 0281 part 1, class 43 UL-Std. 1581. PVC TI1 can be offered upon request. Inner Sheath: PVC Type YM5 according to DIN VDE 0207 part 5. PVC TM5 can be offered upon request. Screen: Tinned copper braid. Outer Sheath: PVC Type YM5 according to DIN VDE 0207 part 5, class 43 UL-Std. 1581. PVC TM5 can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free 134

600V flexing: -5℃~+90℃; fixed: -40℃~+90℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.5 3G0.5 4G0.5 5G0.5 7G0.5 9G0.5 12G0.5 18G0.5 25G0.5 34G0.5 41G0.5 2×1 3G1 4G1 5G1 7G1 9G1 12G1 18G1 25G1 34G1 41G1 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 9G1.5 12G1.5 18G1.5 25G1.5 34G1.5 41G1.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 9G2.5

Nominal Overall Diameter mm 7.8 8.1 8.7 9.3 10.6 12.4 13.1 15.7 18.3 20.2 22.4 8.2 8.5 9.2 10.1 11.4 13.4 13.9 16.3 19.6 22.6 24.4 8.8 9.3 10.1 10.9 13.0 14.9 15.7 18.4 22.4 25.3 27.5 10.4 10.9 11.9 13.3 15.7 18.2

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 93 124 133 153 191 243 322 374 436 560 663 107 130 155 181 209 321 341 473 650 781 892 136 165 192 224 273 340 461 674 950 1203 1588 173 220 270 329 428 580

135


Caledonian Windmill Cables

Control Cable Construction No. of cores×mm² 12G2.5 18G2.5 25G2.5 2×4 3G4 4G4 5G4 7×4 2G6 3G6 4G6 5G6 7G6 3G10 4G10 5G10 7G10 3G70 3G16 4G16 5G16 7G16 3G25 4G25 5G25 7G25 3G35 4G35 5G35 3G50 4G50 5G50 3G70 4G70 5G70 3G95 4G95 5G95 3G120 4G120 5G120 G: with green-yellow earth core

Nominal Overall Diameter mm 19.3 23.2 28.5 12.6 13.2 14.6 15.9 19.1 14.3 15.3 16.7 18.5 22.2 19.2 21.3 23.9 26.7 41.4 24.4 27.4 30.8 33.8 30.4 33.5 40.0 40.8 34.0 37.9 41.7 35.0 40.5 44.4 41.4 46.1 50.6 46.2 50.7 56.1 52.0 57.0 62.7

×: without green-yellow earth core. 136

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 761 1140 1551 209 310 456 532 737 318 411 572 732 961 741 988 1202 1743 3647 1088 1662 2021 2720 1947 2591 3197 4530 2701 3277 4530 2870 3960 4371 3647 4882 5876 4751 6368 7843 5899 8010 9205


Caledonian Windmill Cables

Control Cable Wind Turbine Tray cable (WTTC) »» Application These cables are intended to be installed in cable trays or raceways within wind turbine generators.

»» Standards UL Type WTTC UL: TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12) UL Type MTW, UL 1277

»» Construction Stranded Copper Conductor PVC/Nylon Insulation PVC Sheath

Conductor: Stranded copper conductor. Insulation: Special PVC core insulation with transparent nylon skin. XLPE/EPR can be offered upon request. Screen (optional): Tinned copper braid can be offered upon request. Sheath: Special PVC. Special XL compound can be offered upon request.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free UV Resistant

600V (TC), 1000V (AWM), 1000 V (WTTC) -40℃~+90℃ 5×OD FT4, IEEE 1202/383 Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

137


Caledonian Windmill Cables

Control Cable »» Dimensions and Weight Construction No. Of Cores 2 3 4 5 7 9 10 12 15 16 18 19 25 27 34 37 41 50 61 2 3 4 5 6 7 8 9 10 12 14 15 16 18 19 20 25 138

Nominal Overall Diameter mm 18AWG 7.0 7.1 8.0 8.6 9.3 10.7 11.6 11.9 13.2 13.3 14.6 14.7 17.0 17.4 19.3 19.8 20.7 23.5 24.9 16AWG 7.5 7.8 8.5 9.3 10.0 10.1 10.9 11.7 12.4 12.9 14.5 15.0 15.2 15.9 16.0 16.5 18.6 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 68 88 98 116 149 186 199 245 292 306 366 384 451 521 625 684 744 933 1095 80 86 115 126 164 171 201 237 259 301 365 379 405 443 458 491 564


Caledonian Windmill Cables

Control Cable Construction No. Of Cores 27 30 34 40 41 50 61 2 3 4 5 6 9 10 12 16 18 19 25 2 3 4 5 6 7 9 12 16 19 20 25 2 3 4 5 7 9 12

Nominal Overall Diameter mm 19.0 19.6 20.5 22.9 23.4 25.1 27.2 14AWG 8.6 8.9 9.8 10.6 11.6 13.5 15.5 15.9 17.6 18.3 18.5 21.6 12AWG 9.5 10.0 10.9 11.9 13.0 13.1 15.9 17.8 19.8 20.8 21.9 25.3 10AWG 11.9 12.6 14.7 16.0 17.4 20.4 23.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 629 701 775 946 967 1137 1345 100 112 141 152 205 312 378 434 550 616 634 817 132 177 201 274 315 353 476 613 783 918 961 1236 213 283 387 473 607 771 1061

139


Caledonian Windmill Cables

Control Cable Construction No. Of Cores 19 4 5 3 4 5 3 4 5 3 4 5 4 4 4 4 4 4 4 4

140

Nominal Overall Diameter mm 27.9 8AWG 19.7 21.7 6AWG 19.5 21.9 24.0 4AWG 24.3 27.1 29.3 2AWG 27.9 31.4 34.0 1AWG 34.8 1/0MCM 37.9 2/0MCM 41.3 3/0MCM 48.6 4/0MCM 51.2 250MCM 55.0 350MCM 63.5 500MCM 73.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 1528 662 784 701 908 1149 1060 1366 1631 1480 1922 2363 2397 2938 3559 4181 5747 7591 8299 10549


Caledonian Windmill Cables

Data Cable LiYCY Data Cable »» Application These screened cables are designed for special purpose of data transmission in wind turbines, suitable for in dry, moist and wet rooms.

»» Standards DIN VDE 0245, 0812

»» Construction

Stranded Copper Conductor PVC Insulation Tinned Copper Braid PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228. Insulation: PVC type TI2. Drain Wire: Tinned copper conductor. Screen: Tinned copper wire braid. Sheath: PVC type TM2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

350V (<0.25 mm²); 500V (≥0.25 mm²) flexing: -5℃~+80℃; fixed: -40℃~+80℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

141


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 1×0.14 2×0.14 3×0.14 4×0.14 5×0.14 6×0.14 7×0.14 8×0.14 10×0.14 12×0.14 14×0.14 16×0.14 18×0.14 20×0.14 21×0.14 24×0.14 25×0.14 27×0.14 30×0.14 32×0.14 36×0.14 40×0.14 42×0.14 44×0.14 48×0.14 52×0.14 56×0.14 61×0.14 80×0.14 100×0.14 1×0.25 2×0.25 3×0.25 4×0.25 5×0.25 6×0.25 7×0.25 8×0.25 10×0.25 12×0.25 14×0.25 16×0.25

142

Nominal Overall Diameter mm 2.5 3.7 3.9 4.1 4.4 4.9 4.9 5.2 6.2 6.2 6.6 6.9 7.2 7.7 7.9 8.3 8.5 8.5 9.3 9.6 9.9 10.2 10.5 11.2 11.3 11.8 12.1 12.4 14.1 15.5 2.9 4.2 4.3 4.7 5.3 5.7 5.7 6.6 7.2 7.3 7.9 8.3

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 16 20 27 32 37 42 48 55 65 77 79 89 103 116 120 131 136 142 157 163 182 209 217 226 240 270 320 370 510 580 27 31 36 40 51 58 64 82 85 90 110 142


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 18×0.25 19×0.25 20×0.25 21×0.25 24×0.25 25×0.25 27×0.25 30×0.25 32×0.25 36×0.25 37×0.25 40×0.25 42×0.25 44×0.25 48×0.25 52×0.25 56×0.25 61×0.25 80×0.25 100×0.25 1×0.34 2×0.34 3×0.34 4×0.34 5×0.34 6×0.34 7×0.34 8×0.34 10×0.34 12×0.34 14×0.34 16×0.34 18×0.34 19×0.34 20×0.34 21×0.34 24×0.34 25×0.34 27×0.34 30×0.34 32×0.34 36×0.34 37×0.34 40×0.34 42×0.34 44×0.34

Nominal Overall Diameter mm 8.9 9.1 9.4 9.4 10.0 10.1 10.1 11.1 11.1 11.9 11.9 12.4 12.8 12.8 13.5 14.1 14.5 14.9 17.1 19.6 3.2 4.8 5.2 5.5 6.0 6.7 6.7 7.8 8.4 8.5 9.0 9.4 9.8 9.9 10.1 10.7 10.7 12.0 12.1 12.1 12.6 12.6 13.7 13.7 14.6 14.6

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 144 146 150 152 163 169 176 189 204 219 230 247 269 292 317 330 343 365 480 605 24 30 37 48 54 61 67 81 103 110 153 159 172 181 191 199 229 241 258 290 305 330 348 364 389 414

143


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 48×0.34 52×0.34 56×0.34 61×0.34 80×0.34 100×0.34 1×0.5 2×0.5 3×0.5 4×0.5 5×0.5 6×0.5 7×0.5 8×0.5 10×0.5 12×0.5 14×0.5 16×0.5 18×0.5 19×0.5 20×0.5 24×0.5 25×0.5 27×0.5 30×0.5 32×0.5 34×0.5 36×0.5 37×0.5 40×0.5 50×0.5 61×0.5 80×0.5 100×0.5 1×0.75 2×0.75 3×0.75 4×0.75 5×0.75 6×0.75 7×0.75 8×0.75 10×0.75 12×0.75 14×0.75 16×0.75

144

Nominal Overall Diameter mm 14.6 14.6 16.2 16.6 17.1 19.4 3.4 5.3 5.6 6.0 6.7 7.3 7.3 8.5 9.2 9.5 10.0 10.6 10.7 11.2 11.9 12.6 12.7 12.7 14.0 14.5 15.3 15.3 16.3 16.3 18.0 19.1 21.8 24.3 3.8 6.0 6.2 6.7 7.3 8.1 8.2 9.0 10.3 10.4 11.2 11.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 420 450 480 520 580 694 40 45 55 61 76 89 98 117 135 157 190 210 217 246 275 337 351 373 396 431 440 445 458 470 570 650 780 990 41 59 66 77 93 113 130 145 180 202 225 275


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 18×0.75 19×0.75 20×0.75 24×0.75 25×0.75 27×0.75 30×0.75 32×0.75 34×0.75 36×0.75 37×0.75 40×0.75 42×0.75 61×0.75 80×0.75 100×0.75 2×1 3×1 4×1 5×1 6×1 7×1 8×1 10×1 12×1 14×1 16×1 19×1 24×1 27×1 37×1 2×1.5 3×1.5 4×1.5 5×1.5 6×1.5 7×1.5 8×1.5 10×1.5 12×1.5 14×1.5 16×1.5 19×1.5 24×1.5 27×1.5 37×1.5

Nominal Overall Diameter mm 12.6 12.6 13.1 14.1 14.3 14.3 15.7 16.3 17.1 17.1 17.6 17.8 18.4 21.5 24.5 27.2 6.4 6.7 7.2 8.0 8.6 8.6 10.0 11.2 11.4 12.0 12.8 13.4 15.2 15.4 18.9 7.3 7.6 8.2 9.1 9.9 9.9 10.8 13.2 13.2 13.9 14.8 15.6 17.6 17.9 21.9

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 292 322 362 415 435 467 486 530 570 600 640 680 714 900 1200 1440 65 80 98 127 144 158 197 232 260 302 346 412 493 562 790 88 100 126 160 192 208 244 315 338 383 424 506 690 781 941

145


Caledonian Windmill Cables

Data Cable LiYCY Twisted Pair Data Cable »» Application These screened cables are designed for special purpose of data transmission in wind turbines, suitable for in dry, moist and wet rooms.

»» Standards DIN VDE 0812, 0814

»» Construction Stranded Copper Conductor PVC Insulation Twisted Pair Tinned Copper Braid PVC Sheath

Conductor: Stranded bare copper, class 5 according to DIN VDE 0295/IEC60228.. Insulation: PVC Type YI2. Cable Element: Twisted pairs. Screen: Tinned copper wire braid. Sheath: PVC Type YM2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

146

350V flexing: -5℃~+80℃; fixed: -30℃~+80℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 1×2×0.14 2×2×0.14 3×2×0.14 4×2×0.14 5×2×0.14 6×2×0.14 7×2×0.14 8×2×0.14 10×2×0.14 12×2×0.14 14×2×0.14 15×2×0.14 16×2×0.14 18×2×0.14 20×2×0.14 22×2×0.14 24×2×0.14 25×2×0.14 26×2×0.14 27×2×0.14 28×2×0.14 30×2×0.14 32×2×0.14 34×2×0.14 36×2×0.14 38×2×0.14 40×2×0.14 44×2×0.14 46×2×0.14 50×2×0.14 52×2×0.14 55×2×0.14 1×2×0.25 2×2×0.25 3×2×0.25 4×2×0.25 5×2×0.25 6×2×0.25 7×2×0.25

Nominal Overall Diameter mm 3.5 5.6 5.6 6.0 6.7 7.2 7.2 8.4 9.1 9.2 9.9 10.4 10.4 11.0 11.5 12.3 12.3 12.5 12.5 12.5 13.7 13.7 14.2 14.7 14.9 15.6 16.1 16.8 17.0 17.7 17.7 18.2 4.1 6.3 6.6 7.0 7.8 8.6 8.6

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 34 40 49 55 66 86 91 97 109 141 148 152 155 171 183 205 228 239 245 251 258 270 284 300 316 350 370 390 430 440 460 480 45 53 65 80 98 114 121

147


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 8×2×0.25 10×2×0.25 12×2×0.25 14×2×0.25 15×2×0.25 16×2×0.25 18×2×0.25 20×2×0.25 22×2×0.25 24×2×0.25 25×2×0.25 26×2×0.25 27×2×0.25 28×2×0.25 30×2×0.25 32×2×0.25 34×2×0.25 36×2×0.25 38×2×0.25 40×2×0.25 44×2×0.25 46×2×0.25 50×2×0.25 52×2×0.25 55×2×0.25 1×2×0.34 2×2×0.34 3×2×0.34 4×2×0.34 5×2×0.34 6×2×0.34 7×2×0.34 8×2×0.34 9×2×0.34 10×2×0.34 12×2×0.34 14×2×0.34 16×2×0.34 18×2×0.34 21×2×0.34 25×2×0.34 27×2×0.34 30×2×0.34

148

Nominal Overall Diameter mm 9.8 11.0 11.2 12.2 12.8 12.8 13.5 14.1 14.9 15.3 15.5 15.5 15.5 17.0 17.0 17.6 18.2 18.2 19.0 19.7 20.5 20.7 21.5 21.5 22.1 5.4 7.0 7.3 8.1 8.8 9.8 9.8 11.2 12.6 12.6 12.8 13.3 14.3 15.2 15.9 17.5 17.5 19.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 129 157 189 213 225 237 248 275 303 330 343 345 350 360 375 400 410 420 450 485 500 540 550 580 630 58 65 78 90 110 130 145 150 170 190 220 245 250 275 300 400 410 440


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 34×2×0.34 37×2×0.34 40×2×0.34 44×2×0.34 50×2×0.34 52×2×0.34 56×2×0.34 61×2×0.34 1×2×0.5 2×2×0.5 3×2×0.5 4×2×0.5 5×2×0.5 6×2×0.5 8×2×0.5 10×2×0.5 12×2×0.5 16×2×0.5 20×2×0.5 25×2×0.5 1×2×0.75 2×2×0.75 3×2×0.75 4×2×0.75 5×2×0.75 6×2×0.75 8×2×0.75 10×2×0.75 12×2×0.75 16×2×0.75 20×2×0.75 25×2×0.75 1×2×1 2×2×1 3×2×1 4×2×1 1×2×1.5 2×2×1.5 3×2×1.5 4×2×1.5

Nominal Overall Diameter mm 20.8 21.5 22.4 23.6 24.8 24.8 25.4 26.2 4.9 7.8 8.2 9.1 9.9 10.7 12.8 14.0 14.3 16.1 17.2 17.9 5.2 8.4 8.9 9.8 10.8 12.1 13.4 15.5 15.8 18.0 19.2 21.8 5.3 8.9 9.4 10.4 5.8 10.2 10.8 12.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 510 550 590 600 650 680 750 840 60 89 104 126 148 171 290 320 361 421 580 740 71 105 128 156 189 216 309 355 405 565 700 950 75 116 140 191 84 122 194 240

149


Caledonian Windmill Cables

Data Cable LiHH Multicore Halogen-free Data Cable »» Application These halogen-free cables are designed for special purpose of data transmission in wind turbines, suitable for indoor and outdoor installation.

»» Standards VDE 0812

»» Construction Stranded Copper Conductor Halogen Free Insulation Halogen Free Sheath

Conductor: Stranded bare copper. Insulation: Halogen free compound. Sheath: Halogen free compound.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Gases Corrosively Halogen Free Oil Resistant

150

250V flexing: -5℃~+70℃; fixed: -40℃~+70℃ flexing: 10×OD; fixed: 7.5×OD DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-3 VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 5×0.14 6×0.14 7×0.14 8×0.14 10×0.14 12×0.14 20×0.14 25×0.14 2×0.25 3×0.25 4×0.25 5×0.25 6×0.25 7×0.25 8×0.25 10×0.25 12×0.25 16×0.25 2×0.34 3×0.34 4×0.34 5×0.34 7×0.34 10×0.34 12×0.34 3×2×0.34 4×2×0.34 2×0.5 3×0.5 4×0.5 5×0.5 7×0.5 12×0.5 21×0.5 2×0.75

Nominal Overall Diameter mm 3.4 3.6 3.8 4.1 4.4 4.4 5.1 5.4 5.8 7.2 8.0 4.0 4.2 4.5 4.9 5.3 5.3 6.4 7.0 7.2 7.9 4.4 4.6 5.0 5.7 6.1 7.8 8.0 7.4 8.1 4.9 5.2 5.8 6.3 7.0 9.1 11.5 5.3 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 12 15 17 22 25 26 29 35 43 71 91 22 25 28 34 39 42 50 60 67 85 28 30 40 44 60 80 97 49 60 31 37 45 58 72 117 176 41 151


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 4×0.75 5×0.75 7×0.75 12×0.75 3×1 4×1 3×1.5 4×1.5 5G1.5 7G1.5 5G2.5

152

Nominal Overall Diameter mm 6.3 7.1 7.7 10.4 6.1 6.6 7.4 8.0 8.4 9.1 10.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 60 70 85 165 57 67 72 87 118 150 198


Caledonian Windmill Cables

Data Cable LiHCH Multicore Halogen-free Data Cable »» Application These screened, halogen-free cables are designed for special purpose of data transmission in wind turbines, suitable for indoor and outdoor installation.

»» Standards VDE 0812

»» Construction

Stranded Copper Conductor Halogen Free Insulation Tinned Copper Braid Halogen Free Sheath

Conductor: Stranded bare copper. Insulation: Halogen free compound. Screen: Tinned copper wire braid. Sheath: Halogen free compound.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively Oil Resistant

250V flexing: -5℃~+70℃; fixed: -40℃~+70℃ flexing: 10×OD; fixed: 7.5×OD DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754 Yes

www.caledonian-cables.co.uk www.addison-cables.com

153


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 6×0.14 7×0.14 8×0.14 12×0.14 16×0.14 25×0.14 2×0.25 3×0.25 4×0.25 6×0.25 7×0.25 8×0.25 10×0.25 25×0.25 2×0.34 3×0.34 4×0.34 5×0.34 7×0.34 8×0.34 10×0.34 16×0.34 25×0.34 2×0.5 3×0.5 4×0.5 5×0.5 6×0.5 7×0.5 8×0.5 10×0.5 12×0.5 18×0.5 25×0.5 2×0.75 154

Nominal Overall Diameter mm 4.1 4.3 4.5 5.1 5.1 6.0 6.5 7.2 8.7 4.7 4.9 5.2 6.2 6.2 7.3 7.7 10.9 5.1 5.3 5.9 6.4 7.0 8.0 8.5 9.6 12.1 5.8 6.1 6.5 7.2 7.8 7.8 8.9 9.5 9.8 11.7 13.9 6.2 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 22 25 29 35 38 41 78 90 149 25 30 35 49 52 58 81 172 30 35 42 53 73 84 101 160 259 38 47 67 76 84 91 131 135 177 239 352 45


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 3×0.75 4×0.75 5×0.75 7×0.75 12G0.75 18G0.75 2×1 3×1 4×1 7×1 10×1 12G1 16×1 19G1 2×1.5 3×1.5 5×1.5 12G1.5 18G1.5 15G2.5

Nominal Overall Diameter mm 6.5 7.2 7.8 8.3 10.7 12.4 6.5 7.0 7.5 8.8 11.2 11.3 12.5 13.1 7.7 8.1 9.5 13.0 15.5 19.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 69 80 99 120 168 237 72 90 109 171 184 205 250 291 90 115 176 271 400 587

155


Caledonian Windmill Cables

Data Cable LiHCH Twisted Pair Halogen-free Data Cable »» Application These screened flexible cables are designed for special purpose of data transmission in wind turbines, suitable for indoor and outdoor installation.

»» Standards DIN VDE 0812

»» Construction Stranded Copper Conductor PE Insulation Twisted Pair Tinned Copper Braid Halogen Free Sheath

Conductor: Stranded bare copper. Insulation: PE compound type 2YJ1. Cable Element: Twisted pairs. Screen: Tinned copper wire braid. Sheath: Halogen free compound type HM2.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Gases Corrosively

156

350V (≤0.14 mm²); 500V (>0.14 mm²) flexing: -5℃~+70℃; fixed: -40℃~+70℃ flexing: 10×OD; fixed: 7.5×OD DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1 VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×2×0.14 3×2×0.14 4×2×0.14 5×2×0.14 6×2×0.14 7×2×0.14 10×2×0.14 12×2×0.14 15×2×0.14 18×2×0.14 2×2×0.25 3×2×0.25 4×2×0.25 5×2×0.25 6×2×0.25 7×2×0.25 10×2×0.25 12×2×0.25 15×2×0.25 18×2×0.25 2×2×0.34 3×2×0.34 4×2×0.34 5×2×0.34 6×2×0.34 7×2×0.34 10×2×0.34 12×2×0.34 15×2×0.34 18×2×0.34 2×2×0.5 3×2×0.5 4×2×0.5 5×2×0.5 6×2×0.5 7×2×0.5 10×2×0.5 12×2×0.5

Nominal Overall Diameter mm 5.2 6.2 6.4 7.2 8.2 8.7 9.9 10.0 11.3 12.5 6.1 7.0 7.5 8.2 9.3 9.4 10.6 11.4 12.9 13.7 7.3 8.6 9.6 10.1 10.6 11.0 13.1 14.4 15.2 16.9 7.6 9.0 10.3 10.8 11.4 11.8 14.3 15.1

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 37 47 66 76 87 94 119 135 157 190 44 66 81 98 116 120 153 175 213 248 68 92 110 128 147 154 209 245 279 363 76 107 134 150 176 185 275 330 157


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 15×2×0.5 18×2×0.5 2×2×0.75 3×2×0.75 4×2×0.75 5×2×0.75 6×2×0.75 7×2×0.75 10×2×0.75 12×2×0.75 15×2×0.75 18×2×0.75

158

Nominal Overall Diameter mm 17.0 18.3 9.0 10.1 11.5 12.4 12.5 13.6 15.7 17.8 19.3 20.6

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 380 450 105 137 166 200 236 255 363 434 500 580


Caledonian Windmill Cables

Data Cable LiYY Data Cable UL »» Application These data cables are designed for use as measuring and control cables in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries.

»» Standards UL Style 2464 UL Style 1061/1729 UL Style 1007/1569

»» Construction

Stranded Copper Conductor PVC Insulation PVC Sheath

Conductor: Stranded tinned copper, according to ASTM-B. Insulation: PVC class 43. Sheath: PVC class 43.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

300V flexing: -10℃~+80℃; fixed: -20℃~+80℃ flexing: 15×OD; fixed: 6×OD UL VW-1/CSA FT-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

159


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 6×0.14 10×0.14 12×0.14 16×0.14 18×0.14 24×0.14 27×0.14 30×0.14 2×0.23 3×0.23 4×0.23 6×0.23 10×0.23 12×0.23 16×0.23 18×0.23 24×0.23 27×0.23 30×0.23 2×0.34 3×0.34 4×0.34 6×0.34 10×0.34 12×0.34 16×0.34 18×0.34 24×0.34 27×0.34 30×0.34 2×0.56 160

Nominal Overall Diameter mm 26AWG 3.6 3.7 4.0 4.6 5.6 5.8 6.3 6.6 7.5 7.8 8.1 24AWG 3.8 4.0 4.2 4.9 6.0 6.1 6.7 7.1 8.2 8.5 8.8 22AWG 4.2 4.3 4.6 5.5 6.8 7.0 7.8 8.3 9.6 10.0 10.5 20AWG 4.6

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 13 15 18 25 38 46 56 62 82 97 110 16 19 23 32 55 60 75 82 116 140 150 25 30 45 60 80 105 130 140 190 207 225 30


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 3×0.56 4×0.56 6×0.56 10×0.56 12×0.56 16×0.56 18×0.56 24×0.56 27×0.56 30×0.56 2×0.82 3×0.82 4×0.82 6×0.82 10×0.82 12×0.82 16×0.82 18×0.82 24×0.82 27×0.82 30×0.82 2×1.3 3×1.3 4×1.3 6×1.3 10×1.3 12×1.3 16×1.3 18×1.3 24×1.3 27×1.3 30×1.3

Nominal Overall Diameter mm 4.8 5.2 6.1 7.6 8.0 8.8 9.4 11.0 11.3 11.8 18AWG 6.1 6.4 6.9 8.1 10.4 10.9 12.2 13.0 15.2 15.8 16.3 16AWG 6.9 7.3 7.9 9.6 12.4 12.8 14.6 15.5 18.1 18.7 19.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 33 41 65 102 120 152 168 224 260 300 50 62 72 100 180 182 240 270 370 400 470 70 90 110 160 250 300 400 450 650 680 750

161


Caledonian Windmill Cables

Data Cable LiYCY Data Cable UL »» Application These screened data cables are suitable for use as flexible connector cables in the fields of electronics, control and command technology as well as for measuring, signal and impulse transfer.

»» Standards UL Style 2464 UL Style 1061/1729 UL Style 1007/1569

»» Construction

Stranded Copper Conductor PVC Insulation Tinned Copper Braid PVC Sheath

Conductor: Stranded tinned copper, according to ASTM-B. Insulation: PVC class 43. Drain Wire: Tinned copper conductor. Screen: Tinned copper wire braid. Sheath: PVC class 43.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

162

300V flexing: -10℃~+80℃; fixed: -20℃~+80℃ flexing: 15×OD; fixed: 6×OD UL VW-1/CSA FT-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 6×0.14 10×0.14 12×0.14 16×0.14 18×0.14 24×0.14 27×0.14 30×0.14 2×0.23 3×0.23 4×0.23 6×0.23 10×0.23 12×0.23 16×0.23 18×0.23 24×0.23 27×0.23 30×0.23 2×0.34 3×0.34 4×0.34 6×0.34 10×0.34 12×0.34 16×0.34 18×0.34 24×0.34 27×0.34 30×0.34 2×0.56

Nominal Overall Diameter mm 26AWG 4.1 4.3 4.5 5.1 6.1 6.3 6.8 7.0 8.1 8.3 8.6 24AWG 4.3 4.5 4.8 5.4 6.5 6.7 7.4 7.7 8.8 9.0 9.3 22AWG 4.7 4.9 5.5 6.0 7.4 7.6 8.3 8.7 10.0 10.2 10.5 20AWG 5.1 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 20 25 28 30 50 53 60 70 100 105 110 20 25 30 40 60 70 90 123 131 160 170 40 50 60 80 130 140 160 170 220 250 280 50 163


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 3×0.56 4×0.56 6×0.56 10×0.56 12×0.56 16×0.56 18×0.56 24×0.56 27×0.56 30×0.56 2×0.82 3×0.82 4×0.82 6×0.82 10×0.82 12×0.82 16×0.82 18×0.82 24×0.82 27×0.82 30×0.82 2×1.3 3×1.3 4×1.3 6×1.3 10×1.3 12×1.3 16×1.3 18×1.3 24×1.3 27×1.3 30×1.3

164

Nominal Overall Diameter mm 5.3 5.6 6.5 8.2 8.4 9.3 9.7 11.3 11.5 12.3 18AWG 6.5 6.8 7.4 8.8 10.9 11.2 12.9 13.5 15.6 15.9 16.6 16AWG 7.0 7.4 8.1 9.5 12.4 12.8 14.0 14.8 17.2 18.0 18.7

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 55 61 90 133 151 190 216 339 374 397 60 75 90 125 180 220 290 300 450 470 490 90 160 200 290 450 600 650 680 900 990 1050


Caledonian Windmill Cables

Data Cable LiYY Twisted Pair Data Cable UL »» Application These twisted pair control cables are suitable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries.

»» Standards UL Style 2464 UL Style 1061/1729

»» Construction Stranded Copper Conductor PVC Insulation Twisted Pair PVC Sheath

Conductor: Stranded tinned copper, according to ASTM-B. Insulation: PVC class 43. Cable Element: Twisted pairs. Sheath: PVC class 43.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

300V flexing: -10℃~+80℃; fixed: -20℃~+80℃ flexing: 15×OD; fixed: 6×OD UL VW-1/CSA FT-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

165


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 1×2×0.14 2×2×0.14 3×2×0.14 4×2×0.14 5×2×0.14 6×2×0.14 7×2×0.14 8×2×0.14 10×2×0.14 12×2×0.14 14×2×0.14 15×2×0.14 16×2×0.14 18×2×0.14 20×2×0.14 22×2×0.14 24×2×0.14 25×2×0.14 1×2×0.23 2×2×0.23 3×2×0.23 4×2×0.23 5×2×0.23 6×2×0.23 7×2×0.23 8×2×0.23 10×2×0.23 12×2×0.23 14×2×0.23 15×2×0.23 16×2×0.23 18×2×0.23 20×2×0.23 22×2×0.23 24×2×0.23 25×2×0.23 166

Nominal Overall Diameter mm 26AWG 3.6 5.1 5.3 5.8 6.2 6.8 6.8 7.3 7.4 9.1 9.8 10.6 10.6 11.1 11.9 12.4 13.1 13.4 24AWG 3.8 4.0 5.7 6.0 6.6 7.2 7.2 7.8 9.2 9.7 10.2 10.9 10.9 11.5 12.2 13.0 13.7 14.2 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 20 24 30 38 44 51 57 64 76 93 103 109 112 119 130 150 169 178 32 36 48 56 71 80 89 98 111 135 160 171 185 209 230 248 279 292


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 1×2×0.34 2×2×0.34 3×2×0.34 4×2×0.34 5×2×0.34 6×2×0.34 7×2×0.34 8×2×0.34 10×2×0.34 12×2×0.34 14×2×0.34 15×2×0.34 16×2×0.34 18×2×0.34 20×2×0.34 22×2×0.34 24×2×0.34 25×2×0.34 1×2×0.56 2×2×0.56 3×2×0.56 4×2×0.56 5×2×0.56 6×2×0.56 7×2×0.56 8×2×0.56 10×2×0.56 12×2×0.56 14×2×0.56 15×2×0.56 16×2×0.56 18×2×0.56 20×2×0.56 22×2×0.56 24×2×0.56 25×2×0.56

Nominal Overall Diameter mm 22AWG 4.2 5.9 6.3 7.0 7.6 8.2 8.2 9.0 10.7 11.3 12.1 12.7 12.7 13.6 14.4 15.1 16.2 16.7 20AWG 4.6 6.5 7.1 7.8 8.6 9.6 9.6 12.1 12.5 13.1 13.8 14.7 14.7 15.7 16.7 17.2 18.6 19.2

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 38 44 60 79 92 119 128 139 171 194 222 231 240 264 291 300 359 381 60 80 94 104 130 151 174 262 298 302 327 370 402 480 551 621 703 721

167


Caledonian Windmill Cables

Data Cable LiYCY Twisted Pair Data Cable UL »» Application These twisted pair control cables are suitable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries.

»» Standards UL Style 2464 UL Style 1061/1729

»» Construction Stranded Copper Conductor PVC Insulation Twisted Pair Tinned Copper Braid PVC Sheath

Conductor: Stranded tinned copper, according to ASTM-B. Insulation: PVC class 43. Cable Element: Twisted pairs. Drain Wire: Tinned copper conductor. Screen: Tinned copper wire braid. Sheath: PVC class 43.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Silicone Free

168

300V flexing: -10℃~+80℃; fixed: -20℃~+80℃ flexing: 20×OD; fixed: 10×OD UL VW-1/CSA FT-1 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 1×2×0.14 2×2×0.14 3×2×0.14 4×2×0.14 5×2×0.14 6×2×0.14 7×2×0.14 8×2×0.14 10×2×0.14 12×2×0.14 14×2×0.14 15×2×0.14 16×2×0.14 18×2×0.14 20×2×0.14 22×2×0.14 24×2×0.14 25×2×0.14 1×2×0.23 2×2×0.23 3×2×0.23 4×2×0.23 5×2×0.23 6×2×0.23 7×2×0.23 8×2×0.23 10×2×0.23 12×2×0.23 14×2×0.23 15×2×0.23 16×2×0.23 18×2×0.23 20×2×0.23 22×2×0.23 24×2×0.23 25×2×0.23

Nominal Overall Diameter mm 26AWG 4.0 5.6 5.8 6.3 6.7 7.3 7.3 7.8 9.1 9.8 10.5 11.1 11.1 11.8 12.4 13.1 13.6 15.1 24AWG 4.2 5.9 6.2 6.7 7.2 7.7 7.7 8.4 9.9 10.2 10.9 11.4 11.4 12.2 12.7 13.5 14.5 14.8 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 32 39 47 55 68 86 92 97 111 141 150 154 155 170 183 207 228 239 46 53 65 79 98 114 121 129 152 189 213 225 227 238 270 300 321 340 169


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 1×2×0.34 2×2×0.34 3×2×0.34 4×2×0.34 5×2×0.34 6×2×0.34 7×2×0.34 8×2×0.34 10×2×0.34 12×2×0.34 14×2×0.34 15×2×0.34 16×2×0.34 18×2×0.34 20×2×0.34 22×2×0.34 24×2×0.34 25×2×0.34 1×2×0.56 2×2×0.56 3×2×0.56 4×2×0.56 5×2×0.56 6×2×0.56 7×2×0.56 8×2×0.56 10×2×0.56 12×2×0.56 14×2×0.56 15×2×0.56 16×2×0.56 18×2×0.56 20×2×0.56 22×2×0.56 24×2×0.56 25×2×0.56

170

Nominal Overall Diameter mm 22AWG 4.6 6.4 6.9 7.5 8.1 8.8 8.8 9.7 11.5 12.0 12.6 13.4 13.4 14.4 15.0 15.9 17.0 17.3 20AWG 5.0 7.0 7.6 8.3 9.1 10.1 10.1 12.7 13.2 13.6 14.4 15.5 15.5 16.3 17.1 18.0 19.4 19.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 58 65 78 88 110 126 140 148 184 210 241 245 251 275 300 320 371 402 70 89 102 119 140 162 198 272 307 318 342 381 417 494 570 643 724 740


Caledonian Windmill Cables

Data Cable PUR Sheathed, Halogen Free Data Cable »» Application These halogen free cables are used as drag chain cables for frequent and quick lifting and bending stresses in machine engineering and construction, in robot technology and on permanently moving machine components.

»» Standards UL AWM Style 20233 CSA AWM I/II A/B

»» Construction

Stranded Copper Conductor Polyolefin Insulation PUR Sheath

Conductor: Stranded bare copper, class 6 according to VDE 0295/BS 6360. Insulation: Polyolefin. Sheath: Full polyurethane sheath TMPU.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Oil Resistant Ozone, Oxygen Resistant Silicone Free UV Resistant Abrasion Resistance

300V flexing: -40℃~+80℃; fixed: -50℃~+80℃ flexing: 5×OD; fixed: 3×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

171


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 5×0.14 7×0.14 10×0.14 12×0.14 14×0.14 18×0.14 24×0.14 25×0.14 2×0.25 3×0.25 4×0.25 5×0.25 7×0.25 10×0.25 12×0.25 14×0.25 18×0.25 24×0.25 25×0.25 2×0.34 3×0.34 4×0.34 5×0.34 7×0.34 10×0.34 12×0.34 14×0.34 18×0.34 24×0.34 25×0.34

172

Nominal Overall Diameter mm 26AWG 3.9 4.0 4.3 4.7 5.3 6.1 6.2 6.5 7.2 8.2 8.6 24AWG 4.3 4.5 4.8 5.2 6.0 6.9 7.1 7.4 8.2 9.6 10.1 22AWG 4.6 4.8 5.2 5.6 6.5 7.5 7.7 8.1 9.2 10.7 11.2

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 22 24 29 33 47 57 63 72 80 110 115 26 30 39 44 52 70 84 97 114 157 160 31 38 51 54 77 104 122 140 162 204 229


Caledonian Windmill Cables

Data Cable PUR Sheathed, Screened, Halogen Free Data Cable »» Application These halogen free cables are used as drag chain cables for frequent and fast lifting and bending stresses in machines and tool building, robot systems and constantly moving machine components.

»» Standards UL AWM Style 20233 CSA AWM I/II A/B

»» Construction

Stranded Copper Conductor Polyolefin Insulation Tinned Copper Braid PUR Sheath

Conductor: Stranded bare copper, class 6 according to VDE 0295/BS 6360. Insulation: Polyolefin. Screen: Tinned copper wire braid. Sheath: Full polyurethane sheath TMPU.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Oil Resistant Halogen Free Ozone, Oxygen Resistant Silicone Free UV Resistant Abrasion Resistance

300V flexing: -40℃~+80℃; fixed: -50℃~+80℃ flexing: 7.5×OD; fixed: 4×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

173


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 2×0.14 3×0.14 4×0.14 5×0.14 7×0.14 10×0.14 12×0.14 14×0.14 18×0.14 24×0.14 25×0.14 2×0.25 3×0.25 4×0.25 5×0.25 7×0.25 10×0.25 12×0.25 14×0.25 18×0.25 24×0.25 25×0.25 2×0.34 3×0.34 4×0.34 5×0.34 7×0.34 10×0.34 12×0.34 14×0.34 18×0.34 24×0.34 25×0.34

174

Nominal Overall Diameter mm 26AWG 4.3 4.6 4.8 5.1 5.8 6.8 7.4 7.4 7.8 8.8 9.2 24AWG 5.0 5.2 5.6 5.9 6.8 8.3 8.4 8.9 9.5 10.8 11.3 22AWG 5.4 5.7 6.0 6.5 7.7 9.1 10.0 10.0 10.6 12.1 12.8

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 32 35 40 45 66 86 94 102 118 149 156 38 44 51 68 82 110 124 135 150 194 204 45 60 76 82 110 148 166 185 216 291 305


Caledonian Windmill Cables

Data Cable PUR Sheathed, Screened, Halogen Free, Twisted Pair Data Cable »» Application These halogen free cables are used as drag chain cables for permanent flexible stresses in machineries, machines and tool building, robot systems, constantly moving machine components and multi-shift-operation.

»» Standards UL AWM Style 20233 CSA AWM I/II A/B

»» Construction Stranded Copper Conductor Polyolefine Insulation Twisted Pair Tinned Copper Braid PUR Sheath

Conductor: Stranded bare copper, class 6 according to VDE 0295/BS 6360/IEC 60228. Insulation: Polyolefin. Screen: Tinned copper wire braid. Sheath: Full polyurethane sheath TMPU.

»» Technical Data Rated Voltage Uo/U (Um) Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Oil Resistant Ozone Resistant Silicone Free UV Resistant Abrasion Resistance

350V flexing: -40℃~+80℃; fixed: -50℃~+80℃ flexing: 10×OD; fixed: 5×OD VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1 Yes Yes Yes Yes Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

175


Caledonian Windmill Cables

Data Cable »» Dimensions and Weight Construction No. of cores×mm² 1×2×0.25 2×2×0.25 3×2×0.25 4×2×0.25 5×2×0.25 6×2×0.25 8×2×0.25 10×2×0.25 14×2×0.25 1×2×0.34 2×2×0.34 3×2×0.34 4×2×0.34 5×2×0.34 6×2×0.34 8×2×0.34 10×2×0.34 14×2×0.34 1×2×0.5 2×2×0.5 3×2×0.5 4×2×0.5 5×2×0.5 6×2×0.5 8×2×0.5 10×2×0.5 14×2×0.5 1×2×0.75 2×2×0.75 3×2×0.75 4×2×0.75 5×2×0.75 6×2×0.75 8×2×0.75 176

Nominal Overall Diameter mm 24AWG 4.8 6.7 7.1 7.6 8.3 8.9 9.3 11.7 12.7 22AWG 5.1 7.2 7.6 8.2 9.0 9.7 10.3 12.8 13.8 20AWG 5.6 8.4 8.9 9.7 10.7 11.7 12.4 15.6 17.1 19AWG 6.1 9.1 9.6 10.7 11.7 12.9 13.7 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 26 61 70 82 99 126 147 179 210 35 80 100 118 134 162 214 270 304 47 100 131 149 169 181 274 332 390 56 102 144 160 193 216 327


Caledonian Windmill Cables

Data Cable Construction No. of cores×mm² 10×2×0.75 14×2×0.75 1×2×1 2×2×1 3×2×1 4×2×1 5×2×1

Nominal Overall Diameter mm 17.2 18.8 18AWG 6.5 10.0 10.6 11.7 13.2

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 451 521 64 120 160 184 217

177


Caledonian Windmill Cables

Communication Cable PUR Sheathed, Halogen Free CAN BUS 2×2×0.22mm² »» Application These cables with its oil-resistant PUR sheath and increased temperature resistance are employed in the wind turbine area and similar sectors for monitoring wind speed, temperature and performance parameters.

»» Standards ISO 11898-2

»» Construction Stranded Copper Conductor TPE Insulation Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid PUR Sheath

Conductor: Stranded bare copper 7×0.203 mm (Section 0.22 mm²) Insulation: TPE compound. Center Filler: Fibrillated polypropylene ller. Cable Element: Star quad. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape (Aluminium outside). Overall Screen: Tinned copper braid. Sheath: PUR compound.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance Maximum Conductor Resistance @20°C

178

-25℃~+100℃ flexing: 10×OD; fixed installation: 5×OD 120Ohm +/-15% 98Ohm/km

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Communication Cable Nominal Mutual Capacitance Minimum Insulation resistance Flame Retardant Halogen Free Gases Corrosively Smoke Density Oil Resistant Ozone Resistant UV Resistant

41nF/km 1GOhm×km EN 50265-2-1/IEC 60332-1 HD22.13/EN50267-1/IEC 60754 HD22.13/EN50267-2/IEC 60754 EN50268/IEC 61034 Yes Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×2×0.22

Nominal Overall Diameter mm 6.4

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 60

179


Caledonian Windmill Cables

Communication Cable PUR Sheathed CAN BUS 2×2×0.25mm² »» Application These cables with its oil-resistant PUR sheath and increased temperature resistance is employed in the wind turbine area and similar sectors for monitoring wind speed, temperature and performance parameters.

»» Standards

XLPE Insulation Stranded Copper Conductor Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid PUR Sheath

UL/CSA 21223 DIN 19245 T3 EN 50170

»» Construction Conductor: Stranded bare copper 19×24AWG (Section 0.25 mm²). Insulation: Irradiated cross-linked PE. Cable Element: Double core. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Sheath: PUR compound.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance Maximum Conductor Resistance @20°C Nominal Mutual Capacitance Minimum Insulation resistance Oil Resistant UV Resistant

-40℃~+105℃ 126mm 120Ohm +/-10% 87Ohm/km 42nF/km 1GOhm×km Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×2×0.25 180

Nominal Overall Diameter mm 8.4 www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 80


Caledonian Windmill Cables

Communication Cable Indoor/Outdoor PROFIBUS »» Application These cables are used in the cell and field area, suitable for indoor or outdoor installation and are equipped with special PVC or PE sheath.

»» Standards DIN 19245 T3 EN 50170

»» Construction Solid Copper Conductor Foam Skin PE Insulation Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid PVC/PE Sheath

Conductor: Bare copper 1×22AWG. Insulation: Foam skin PE. Cable Element: Two cores with filler. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Sheath: PVC/PE.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance Maximum Conductor Resistance @20°C Nominal Mutual Capacitance Minimum Insulation Resistance

-40℃~+70℃ 120mm 150Ohm +/-10% 55Ohm/km 35nF/km 1GOhm×km

www.caledonian-cables.co.uk www.addison-cables.com

181


Caledonian Windmill Cables

Communication Cable Attenuation @9.6kHz Attenuation @38.4kHz Attenuation @4kHz Attenuation @16kHz Flame Retardant UV Resistant

<2.5dB/km <4dB/km <22dB/km <42dB/km IEC 60332-1/FT 1/FT 4 Yes

»» Dimensions and Weight Construction No. of cores×mm 1×2×0.64 (PVC Sheath) 1×2×0.64 (PE Sheath)

182

Nominal Overall Diameter mm 8.0 8.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 75 65


Caledonian Windmill Cables

Communication Cable PUR Sheathed, Halogen Free PROFIBUS »» Application These cables are used to interconnect Profibus BUS components for the information exchange between different automation systems as well as for communication with the connected decentralized field units.

»» Standards DIN 19245 T3 EN 50170

»» Construction Stranded/Solid Copper Conductor Foam Skin PE Insulation Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid PUR Sheath

Conductor: Bare copper 1×22AWG (0.64mm) or 19×22AWG (0.8mm). Insulation: Foam skin PE. Cable Element: Two cores with filler. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Sheath: PUR.

»» Technical Data 1×2×0.64mm Operating Temperatures Minimum Bending Radius Impedance Maximum Conductor Resistance @20°C Nominal Mutual Capacitance

1×2×0.8mm -40℃~+70℃ 120mm 150Ohm +/-10%

55Ohm/km 35nF/km

www.caledonian-cables.co.uk www.addison-cables.com

49Ohm/km 29nF/km 183


Caledonian Windmill Cables

Communication Cable Minimum Insulation Resistance Attenuation @9.6kHz Attenuation @38.4kHz Attenuation @4kHz Attenuation @16kHz Flame Retardant Halogen Free Oil Resistant UV Resistant

1GOhm×km <2.5dB/km <4dB/km <22dB/km <42dB/km

1GOhm×km <3dB/km <5dB/km <25dB/km <51dB/km IEC 60332-1 IEC 60754 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm 1×2×0.64 1×2×0.8

184

Nominal Overall Diameter mm 8.0 8.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 71 66


Caledonian Windmill Cables

Communication Cable PROFInet AWG 22/1 »» Application These cables are designed especially for extreme industrial applications, suitable for Ethernet applications.

»» Standards PROFInet Draft

»» Construction Tinned Copper Braid Solid Copper Conductor PE Insulation Polyester Tape Aluminium/Polyester Tape PVC Inner Sheath PVC/PUR Outer Sheath

Conductor: Bare copper 1×22AWG. Insulation: PE. Cable Element: Star quad. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Inner Sheath: PVC. Outer Sheath: PVC/PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance @1~100MHz Maximum Conductor Resistance @20°C Nominal Mutual Capacitance Minimum Insulation Resistance Attenuation @10MHz

-40℃~+70℃ 100mm 100Ohm +/-15% 62Ohm/km 50nF/km 0.5GOhm×km 5.2dB/100m

www.caledonian-cables.co.uk www.addison-cables.com

185


Caledonian Windmill Cables

Communication Cable Attenuation @16MHz Attenuation @62.5MHz Attenuation @100MHz Next @10MHz Next @16MHz Next @62.5MHz Next @100MHz ACR @10MHz ACR @16MHz ACR @62.5MHz ACR @100MHz Flame Retardant Silicone Free UV Resistant

6.9dB/100m 15dB/100m 19.5dB/100m 70dB 65dB 55dB 50dB 64.8dB 58.1dB 40dB 30.5dB IEC 60332-1 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm 2×2×0.64 (PVC outer sheath) 2×2×0.64 (PUR outer sheath)

186

Nominal Overall Diameter mm 6.5 6.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 67 64


Caledonian Windmill Cables

Communication Cable PROFInet AWG 22/7 »» Application These cables with oil-resistant FRNC sheath and increased temperature resistance are designed for extreme industrial applications in the wind turbine area and similar sectors.

»» Standards PROFInet Draft

»» Construction Stranded Copper Conductor XLPE Insulation Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid Cross-linked FRNC Sheath

Conductor: Tinned copper AWG 22/7 (Section 0.34 mm²). Insulation: XLPE. Cable Element: Star quad. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Sheath: Cross-linked FRNC.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance @1~100MHz Maximum Conductor Resistance @20°C Nominal Mutual Capacitance Minimum Insulation Resistance Attenuation @10MHz Attenuation @16MHz

-40℃~+105℃ 46mm 100Ohm +/-15% 60Ohm/km 57nF/km 0.5GOhm×km 6.3dB/100m 8dB/100m

www.caledonian-cables.co.uk www.addison-cables.com

187


Caledonian Windmill Cables

Communication Cable Attenuation @62.5MHz Attenuation @100MHz Next @10MHz Next @16MHz Next @62.5MHz Next @100MHz ACR @10MHz ACR @16MHz ACR @62.5MHz ACR @100MHz Flame Retardant Halogen Free Oil Resistant UV Resistant

16.5dB/100m 21.3dB/100m 70dB 65dB 55dB 50dB 63.7dB 57dB 38.5dB 28.7dB IEC 60332-1 IEC 60754 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm² 2×2×0.34

188

Nominal Overall Diameter mm 6.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 64


Caledonian Windmill Cables

Communication Cable PROFInet AWG 22/19 »» Application These cables are designed especially for extreme industrial applications, suitable for Ethernet applications.

»» Standards PROFInet Draft

»» Construction Stranded Copper Conductor Foam Skin PE Insulation Polyester Tape Aluminium/Polyester Tape Tinned Copper Braid PUR Sheath

Conductor: Tinned copper AWG 22/19. Insulation: Foam skin PE. Cable Element: Star quad. Screen 1: Polyester tape over stranded bundle. Screen 2: Aluminium/Polyester tape. Overall Screen: Tinned copper braid. Sheath: PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance @1~100MHz Maximum Conductor Resistance @20°C Nominal Mutual Capacitance Minimum Insulation Resistance Attenuation @10MHz Attenuation @16MHz

-40℃~+80℃ 46mm 100Ohm +/-15% 60Ohm/km 52nF/km 0.5GOhm×km 7.6dB/100m 10dB/100m

www.caledonian-cables.co.uk www.addison-cables.com

189


Caledonian Windmill Cables

Communication Cable Attenuation @62.5MHz Attenuation @100MHz Next @10MHz Next @16MHz Next @62.5MHz Next @100MHz ACR @10MHz ACR @16MHz ACR @62.5MHz ACR @100MHz Flame Retardant Halogen Free Oil Resistant UV Resistant

26.5dB/100m 41dB/100m 50.3dB 47.3dB 38.4dB 35.3dB 42.7dB 37.3dB 11.9dB 5.7dB IEC 60332-1 IEC 60754 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm 2×2×0.64

190

Nominal Overall Diameter mm 6.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 54


Caledonian Windmill Cables

Communication Cable PUR Sheathed, Halogen Free S-FTP Cat5 »» Application These cables are designed for the most extreme requirements in the industry and other heavy-duty environments in torsion applications.

»» Standards ISO/IEC 11801 EN 50173 EIA/TIA 568-A, Category 5

»» Construction Stranded Copper Conductor Polyolefine Insulation Polyester Foil Polyester Foil Copper Copper Braid PUR Sheath

Conductor: Bare copper 19×26AWG. Insulation: PO. Cable Element: Double core. Shielding: Polyester tape over stranded bundle. Screen 1: Polyester foil copper, bare. Screen 2: Copper braid. Sheath: PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Impedance @1~100MHz Nominal Mutual Capacitance Attenuation @10MHz Attenuation @16MHz

-20℃~+80℃ 80mm 100Ohm +/-15% 50nF/km <1.3dB/100m <1.6dB/100m

www.caledonian-cables.co.uk www.addison-cables.com

191


Caledonian Windmill Cables

Communication Cable Attenuation @62.5MHz Attenuation @100MHz Next @10MHz Next @16MHz Next @62.5MHz Next @100MHz ACR @10MHz ACR @16MHz ACR @62.5MHz ACR @100MHz Flame Retardant Halogen Free Smoke Density Oil Resistant UV Resistant

<3.2dB/100m <4dB/100m 47dB 44dB 35dB 32dB 45.7dB 42.4dB 31.8dB 28dB IEC 60332-1 IEC 60754 IEC 61034 Yes Yes

»» Dimensions and Weight Construction No. of cores×mm 4×2×0.64

192

Nominal Overall Diameter mm 7.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 79


Caledonian Windmill Cables

Fibre Optic Cable A-V(ZN)11Y Fibre Optic Cable »» Application These cables are designed for mobile and flexible use, suitable for use in drag chains.

»» Standards IEC 60794

Optical Fibre Aramid Yarns

»» Construction

Buffer Coating PUR Sheath

Core Type: Tight buffer. Strain Relief: Aramid yarns. Sheath: PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant Ozone Resistant UV Resistant Longitudinally Water-tight Hammer Impact Resistant

-30℃~+70℃ 90mm 110°/m IEC 60332-1 Yes Yes Yes Yes Yes

»» Dimensions and Weight Construction No. of fibres 2 2 4 4 4 8 8

Fibre Type Multimode G50/125 Multimode G62.5/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125

Nominal Overall Diameter mm 5.0 5.0 6.0 6.0 6.0 7.0 7.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 20 20 31 31 31 47 47

193


Caledonian Windmill Cables

Fibre Optic Cable I-V(ZN)Y11Y Fibre Optic Breakout Cable »» Application These flexible and robust cables are designed for industrial use, can use in wind turbines, medium distance communication, factory automation, etc. It contains two break-out units Ø2.2mm, each with a large core step index multi mode fibre.

»» Standards IEC 60794

»» Construction Optical Fibre Aramid Yarns Filler Cord Sheath PUR Sheath

Core Type: Tight buffer. Strain Relief: Aramid yarns. Outer Sheath: PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Torsion Application Oil Resistant

-40℃~+80℃ 50mm 180°/m Yes

»» Dimensions and Weight Construction No. of fibres 2

194

Core/Cladding Diameter Nominal Overall Diameter μm mm 200/230 7.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 43


Caledonian Windmill Cables

Fibre Optic Cable I-V(ZN)H11Y Fibre Optic Breakout Cable »» Application These cables are designed for wind turbine control or LAN backbone, suitable for indoor installation or outdoor installation in ducts.

»» Standards DIN VDE 0888 IEC 60794

»» Construction Optical Fibre Aramid Yarns FRP Strength Member Filler LSZH Sheath PUR Sheath

Core Type: Tight buffer. Strain Relief: Aramid yarns. Break-out Unit Sheath: LSZH. Central Strength Member: Dielectric Material. Outer Sheath: PUR.

»» Technical Data Operating Temperatures Minimum Bending Radius Torsion Application

-40℃~+70℃ 20×OD +/-180° 500 times/2m; +/-360° 5 times/2m

»» Dimensions and Weight Construction No. of fibres 2 2 2

Fibre Type Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125

Nominal Overall Diameter mm 7.5 7.5 7.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 45 45 45

195


Caledonian Windmill Cables

Fibre Optic Cable I-V(ZN)YY Fibre Optic Breakout Cable »» Application These flexible and robust cables are designed for industrial use, suitable for fixed and normal flexible installations.

»» Standards DIN VDE 0888 IEC 60794

Optical Fibre Aramid Yarns PVC Sheath PVC Sheath

»» Construction Core Type: Tight buffer. Strain Relief: Aramid yarns. Break-out Unit Sheath: PVC. Outer Sheath: PVC.

»» Technical Data Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Oil Resistant Ozone Resistant UV Resistant

-40℃~+80℃ During Installation: 60mm; Installation: 45mm 180°/m IEC 60332-1/IEC 60332-3/UL 1685 FT1+FT4 Yes Yes Yes

»» Dimensions and Weight Construction No. of fibres 2

196

Fibre Type HCS 200/230

Nominal Overall Diameter mm 7.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 68


Caledonian Windmill Cables

Fibre Optic Cable I-V(ZN)HH Fibre Optic Breakout Cable »» Application These flexible and robust cables are designed for industrial use, suitable for fixed and normal flexible installations.

»» Standards EN 187000 IEC 60794-2 IEC 60794-2-20 ISO 11801 EN 50173-1

»» Construction Optical Fibre Aramid yarns Central Strength Member LSZH Sheath LSZH Sheath

Core Type: Tight buffer. Strain Relief: Aramid yarns. Break-out Unit Sheath: LSZH. Central Strength Member: FRP strength member, covered with LSZH material as appropriate. Outer Sheath: LSZH.

»» Technical Data Operating Temperatures Minimum Bending Radius Torsion Application Flame Retardant Halogen Free No Acid Matters

-20℃~+70℃ 75~175mm depend on No. of fibres 5 cycles +/- 1 turn IEC 60332-1/IEC 60332-3 IEC 60754 IEC 60754

www.caledonian-cables.co.uk www.addison-cables.com

197


Caledonian Windmill Cables

Fibre Optic Cable Smoke Density UV Resistant

IEC 61034 Yes

»» Dimensions and Weight Construction No. of fibres 2 4 6 8 12 16 24

198

Tight Buffer Fiber Diameter μm 900+/-50 900+/-50 900+/-50 900+/-50 900+/-50 900+/-50 900+/-50

Nominal Overall Diameter

Nominal Weight

mm 7.5 7.5 8.5 10.0 12.5 12.0 14.5

kg/km 60 60 75 100 160 145 210

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian Windmill Cables

Fibre Optic Cable I-V2Y POF Cord »» Application These flexible and robust cables are used in mechanical engineering, both in mobile and fixed applications, suitable for applications where trouble-free data transmission in necessary under heavyduty conditions.

»» Standards DIN VDE 0888 IEC 60794

»» Construction POF

PE Sheath

Fibre Type: POF 980/1000. Sheath: PE.

»» Technical Data Operating Temperatures Minimum Bending Radius

-20℃~+80℃ 25mm

»» Dimensions and Weight Construction No. of POF element 1 2

Core/Cladding Diameter Nominal Overall Diameter μm mm 980/1000 2.2 980/1000 2.2×4.4

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 4 8

199


Caledonian Windmill Cables

Fibre Optic Cable I-V2Y(ZN)11Y/I-V2Y(ZN)2Y POF Breakout Cable »» Application These flexible and robust cables are used in mechanical engineering, both in mobile and fixed applications, suitable for applications where trouble-free data transmission in necessary under heavyduty conditions.

»» Standards POF Cu Element PE Sheath PE/PUR Sheath

DIN VDE 0888 IEC 60794

»» Construction Fibre Type: POF 980/1000. Strain Relief: Aramid yarns. Break-out Unit Sheath: PE. Outer Sheath: PE/PUR. Optional Element: Copper element or dummy element.

»» Technical Data Operating Temperatures Minimum Bending Radius Oil Resistant

-20℃~+80℃ 30~95mm depend on cable construction Yes

»» Dimensions and Weight Construction

Copper Element

No. of POF element 1 2 4 2 2 4

No. of cores×mm² 2×1 3×1.5 19×1

200

Core/Cladding Diameter μm 980/1000 980/1000 980/1000 980/1000 980/1000 980/1000

Nominal Overall Diameter mm 5.8 6.0 7.1 7.8 11.0 16.0

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 30 36 65 60 132 440


Caledonian Windmill Cables

Fibre Optic Cable A-DQ(ZN)BH/I-DQ(ZN)BH Fibre Optic Cables »» Application These cables are used either as central bundle core cable or as stranded versions, suitable for indoor and outdoor cabling of buildings and facilities.

»» Standards DIN VDE 0888 EN 187000 IEC 60794 ISO 11801 EN 50173-1

»» Construction

Fibre Type: Loose Tube. Strain Relief: Aramid. Armour: Glass yarns. Sheath: FRNC.

»» Technical Data Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Corrosive Gases Smoke Density UV Resistant Longitudinally Water-tight

-20℃~+60℃ 150mm IEC 60332-1/IEC 60332-3 IEC 60754 EN 50267-2/ IEC 60754 IEC 61034 Yes Yes

www.caledonian-cables.co.uk www.addison-cables.com

201


Caledonian Windmill Cables

Fibre Optic Cable »» Dimensions and Weight A-DQ(ZN)BH, Central bundle Construction No. of fibres 4~12 4~12 4~12 16~24 16~24 16~24

Fibre Type Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125

Nominal Overall Diameter mm 10.0 10.0 10.0 10.0 10.0 10.0

Nominal Weight kg/km 125 125 125 145 145 145

A-DQ(ZN)BH, Stranded Construction

Fibre Type

No. of fibres 6~36 6~36 6~36 8~48 8~48 8~48 12~72 12~72 12~72 42~48 42~48 42~48 56~64 56~64 56~64 84~96 84~96 84~96

Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125

202

No. of Fibres Per Core 6 6 6 8 8 8 12 12 12 6 6 6 8 8 8 12 12 12

Nominal Overall Diameter mm 13 13 13 13 13 13 13 13 13 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 160 160 160 160 160 160 160 160 160 210 210 210 210 210 210 210 210 210


Caledonian Windmill Cables

Fibre Optic Cable A-DQ(ZN)B2Y Fibre Optic Cables »» Application These cables are easy to mount and rodent-protected, suitable for underground, tubes and channel areas, where normal tensile stresses and/or transverse compressions occur and rodent infestation is to be expected.

»» Standards DIN VDE 0888 IEC 60794

PE Sheath Optical Fibre Loose Tube Glass Yarns

»» Construction Fibre Type: Loose Tube. Strain Relief: Glass yarns. Armour: Glass yarns. Sheath: PE.

»» Technical Data Operating Temperatures Minimum Bending Radius Corrosive Gases UV Resistant Longitudinally Water-tight

-20℃~+60℃ 150mm EN 50267-2 Yes Yes

»» Dimensions and Weight Construction No. of fibres 2~12 2~12 2~12 24 24 24

Fibre Type Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125 Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125

Nominal Overall Diameter mm 7.5 7.5 7.5 8.5 8.5 8.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 40 40 40 60 60 60 203


Caledonian Windmill Cables

Fibre Optic Cable QFCI »» Application These cables are designed for data transmission in the Tower.

»» Standards Loose Tube Optical Fibre Central Strength Member LSZH Inner Sheath Galvanized Steel Wire Braid LSZH/SHF1 Outer Sheath

IEC 60794

»» Construction Fibre Type: Loose Tube. Support Element: Central strength member. Inner Sheath: LSZH. Armour: Galvanized steel wire braid (GSWB). Outer Sheath: SHF1/LSZH.

»» Technical Data Operating Temperatures Minimum Bending Radius Flame Retardant Halogen Free Smoke Density Fire Resistant No-Fire Propagation

-40℃~+70℃ 350mm IEC 60332-3 IEC 60754 IEC 61034 IEC 60331-25 IEC 60331-3-24

»» Dimensions and Weight Construction No. of fibres 2~48 2~48 2~48

204

Fibre Type Multimode G50/125 Multimode G62.5/125 Single-Mode E9/125

Nominal Overall Diameter mm 16.5 16.5 16.5

www.caledonian-cables.co.uk www.addison-cables.com

Nominal Weight kg/km 350 350 350