Cat5

Page 1

ADDISON Fire Resistant UTP CAT5 Data Cables FFX-CAT5UTP4P24FR

LSZH Sheath Plain Annealed Copper PE Insulation

t e

Fire Barrier

n . h

c e -t

APPLICATION

The cables are desgined for structure wiring, compatible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in four pair cable that will continue to transmit data even when being directly attacked by fire.

n o d le

STANDARDS Basic design to EN50173

a c .

Fire Performance

w w w

Circuit Integrity

System circuit integrity

Flame Retardance (Single Vertical Wire Test) Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) Halogen Free No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases

n ia

IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) DIN 4102-12, E30 depending on lay system EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

128

Caledonian


Caledonian

Fire Resistant Coaxial Cables www.caledonian-teh.net

VOLTAGE RATING 80V CABLE CONSTRUCTION Conductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1. Insulation: High density polyethylene (HDPE). Fire Barrier: Fire resistance tape wrapped around the individual pairs. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two-pair cable had four cores laid in quad formation. Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Temperature range during operation (fixed state): -20°C - +60°C Temperature range during installation (mobile state): -5°C - +50°C Minimum bending radius: 10 x Overall Diameter

n o d le

Characteristic Impedance

c e -t

n ia

Electrical Properties

100 Ohm±15%

Nominal Velocity of Propagation (NVP)

69%

Max. DC Resistance

9.38 Ohm/100m

a c .

Max. Resistance Unbalance Max. Mutual Capacitance:

w w w

t e

n . h

Physical AND THERMAL PROPERTIES

5%

5.6 nF/100m

Max. Capacitance Unbalance

330 pF/100m

Max. Propagation Delay Skew

30 ns/100m

Max. Propagation Delay

536 ns/100m@100 mhz

Max. Pulling Load

80N

Transmission Properties Frequency (MHz) 0.722 1 4 8 10 16 20 25

Min.RL (dB) 20.6 18.2 21 22.5 23 23 23 22.3

Max.Attenuation (dB/100m) 0.82 1.0 3.1 4.8 5.5 7.2 8.3 9.4

NEXT (dB) 67 65.3 56.3 51.8 50.3 47.3 45.8 44.3

PSNEXT (dB) 64 62.3 53.3 49.8 47.3 44.3 42.8 41.3

ADDISON

129


ADDISON Frequency (MHz) 31.25 62.5 100

Min.RL (dB) 21.6 19.5 18.1

Frequency (MHz) 0.722 1 4 8 10 16 20 25 31.25 62.5 100

Max.Attenuation (dB/100m) 10.7 16 21

ELFEXT (dB) 66 63.8 51.7 45.7 43.8 39.7 37.7 35.8 33.9 27.8 23.8

PSELFEXT (dB) 63 60.8 48.7 42.7 40.8 36.7 34.7 32.8 30.9 24.8 20.8

n o d le

a c . w N w w

FFX-CAT5UTP4P24FR 80V

EN 50173

W

Rated Voltage

Standard

mm

Nominal Overall Diameter mm

0.51

0.25

7.3Âą1.0

E

Circuit Integrity IEC 60331/BS 6387 NF C32-070-2.3(CR1)

Flame Retardancy Reduced Fire Propagation NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-3-24/EN50266-2-4 IEC60332-1-2/EN50265-2-1

Zero

Low Toxicity NES 02-713/NF C 20-454

130

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Caledonian

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

Halogen Free IEC60754-1 EN50267-2-1

W

ACR (dB) 65 63.3 52.2 46 43.8 39.1 36.5 33.9 31.2 21.4 13.3

t e

n . h

Nominal Insulation Thickness mm

Conductor Diameter

PSNEXT (dB) 39.9 35.4 32.3

c e -t

n ia

CONSTRUCTION PARAMETERS Cable Code

NEXT (dB) 42.9 38.4 35.3

E

Functional Integrity DIN 4102-12

Approx. Weight kg/km 50