Cat6a4p22

Page 1

IEC Standard Caledonian Offshore & Marine Cables MariLan Marine Lan Data & Communication Cables www.caledonian-cables.co.uk

Armoured Cat 6 S/FTP 22AWG Application These Cat6 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class E applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 250MHz.

Standards EN 50288  ISO 11801  IEC 61156-5  IEC 60332-1  IEC 60754-1/2  IEC 61034  IEC 60092-359  UL1581 

LSOH (SHF1) Outer Sheath Solid Copper Conductor PE Insulation Al/polyester Tape Tinned Copper Braid LSOH Inner Sheath Tinned Copper Braid Armour

Construction Conductors: Solid bare copper conductor.  Insulation: PE.  Twinning: Two coloured insulated conductors twisted together to form a pair.  Individual Screen: Al/polyester tape.  Overall Screen: Tinned copper braid.  Inner Sheath: LSOH.  Armour: Tinned copper wire braid.  Outer Sheath: LSOH (SHF1). 

Core Identification Pair 1: White,Blue Pair 2: White,Orange Pair 3: White,Green Pair 4: White,Brown

104 ADDISON

www.addison-cables.com


IEC Standard Caledonian Offshore & Marine Cables MariLan Marine Lan Data & Communication Cables www.caledonian-cables.co.uk

Electrical Properties Maximum DC Loop Resistance Maximum Resistance Unbalance Minimum Insulation Resistance Nominal Capacitance @800Hz Maximum Capacitance Unbalance (pair to ground) Characteristic Impedance @1-100MHz Nominal Velocity of Propagation Maximum Propagation Delay Maximum Delay Skew Maximum Transfer Impedance @1MHz Maximum Transfer Impedance @10MHz Maximum Transfer Impedance @30MHz Maximum Transfer Impedance @100MHz

Ω/km

165 2% 1000 43 1500 100 ± 15 79% 427 12 5 10 30 100

MΩ.km nF/km pF/km Ω ns/100 m ns/100 m mΩ /m mΩ /m mΩ /m mΩ /m

Nominal Transmission Characteristics @20°C F MHz 1 4 10 16 20 31.25 62.50 100 155 200 250 300 400

Attenuation dB/100m 2.0 3.6 5.7 7.2 8.1 10.2 14.7 18.9 24.0 27.0 31.4 34.8 38.1

NEXT dB 90 90 90 90 90 90 90 90 88 88 86 86 86

PS-NEXT dB 87 87 87 87 87 87 87 87 85 85 83 83 83

ACR dB/100m 88 86 84 83 82 80 75 71 64 61 55 51 48

PS-ACR dB/100m 85 83 81 80 79 77 72 68 61 58 52 48 45

ELFEXT dB/100m 85 85 79 75 73 69 63 59 55 53 51 49 44

PS-ELFEXT Return Loss dB/100m dB 82 82 27 76 30 72 30 70 30 66 30 60 30 56 30 52 26 50 25 48 25 46 23 41 23

Mechanical and Thermal Properties Bending Radius: 8×OD (during installation); 4×OD (fixed installed) Temperature Range: -20°C~ +60°C

Dimensions and Weight Part No. MLN-S/FTPCAT6A4P22

Construction No. of elements×No. of cores in element×Cross section(mm²) 4×2×22AWG

Nominal Insulation Thickness mm 0.578

Nominal Sheath Thickness mm Inner

Outer

0.60

1.09

www.addison-cables.com

Nominal Overall Diameter mm 11.20

Nominal Weight kg/km 198

ADDISON 105