Caledonian ULV Cables www.airport-cables.com
-CCTV (Closed Circuit TV)
enquiry@airport-cables.com
Caledonian
CCTV (Closed Circuit TV) Video Cable KX6 LH-FR KX6 LH-FR
LSZH Outer Sheath
m o
Bare Copper PE+Fireproof Tape Insulation
c . s e l b a Bare Copper/Copper Clad Aluminum Screen
APPLICATIONS
The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.
STANDARDS
c rt
Basic design
MIL-C-17
Halogen Free
IEC 60754-1
No corrosive gas emission
IEC 60754-2
Minimum Smoke Emission
IEC 61034-1/2
Reduced Fire Propagation
IEC 60332-3C / NF C 32070-2.2 (C1)
Flame Retardance
IEC 60332-1 / NF C 32-070-2.1 (C2)
Fire Resistance
IEC 60331 / NF C 32070-2.3(CR1)
o p r i a . w
w w
CABLE CONSTRUCTION
Conductors: Bare Copper Insulation: Solid PE+fire resistant tape Screen: Bare copper/copper clad aluminum(CCA)(80% coverage) Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. ELECTRICAL PROPERTIES Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range
75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 87.5 Ohm/Km 21/32.5Ohm/Km 70 °C
ADDISON
21
ADDISON Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30°C - +70°C Temperature range during installation (mobile state): -5ºC - +60ºC Min. Bending Radius: 8 × Overall Diameter ATTENUATION For bare copper braid Frequency Attenuation Attenuation Mhz dB/100 m dB/ft 10 5.0 1.52 50 8.1 2.47 100 13 3.96 200 18.5 5.64 400 22.5 6.86 850 34.5 10.52 950 37.5 11.43 1000 45 13.72
Return Loss Frequency MHz 5-1000
o p r i a . w
w N w Standard
Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4
22
Caledonian
m o
Number & Nominal Diameter of Strands
Nominal Insulation Diameter
Nominal Sheath Thickness
Nominal Overall Diameter
No/mm 7/0.2
mm 3.7
mm 1.0
mm
Halogen Free IEC60754-1
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
KX6 LH-FR MIL-C-17
Attenuation dB/ft 2.47 3.96 5.64 6.86 10.52 11.43 -
c . s e l b a
c rt
Return Loss (dB >=20
CONSTRUCTION PARAMETERS Cable Code
Frequency Mhz 50 100 200 400 850 950 -
For CCA braid Attenuation dB/100 m 8.1 13 18.5 22.5 34.5 37.5 -
Zero
Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1
Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073
6.1
Caledonian ULV Cables www.airport-cables.com
-CCTV (Closed Circuit TV)
enquiry@airport-cables.com
Caledonian
CCTV (Closed Circuit TV) RS485 Data Cable RE-02Y(St)H 1P18A
RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)
LSZH Outer Sheath Fireproof tape
m o
Stranded Tinned Copper PE Insulation
c . s e l b a
Overall AL/Polyester Tape With Tinned Copper Drain Wire
APPLICATIONS
The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.
o p r i a . w
STANDARDS
c rt
Basic design Halogen Free
EIA/TIA 485 IEC 60754-1
No corrosive gas emission
IEC 60754-2
Minimum Smoke Emission
IEC 61034-1/2
w w
Reduced Fire Propagation
IEC 60332-3C / NF C 32070-2.2 (C1)
Flame Retardance
IEC 60332-1 / NF C 32-070-2.1 (C2)
Fire Resistance
IEC 60331-23 / NF C 32-070-2.3(CR1)
CABLE CONSTRUCTION Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Solid or foam PE compound Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Overall screen: Aluminum/ polyester tape with tinned copper drain wire. Fire Barrier: Fireproof Tape Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.
ADDISON
23
ADDISON Electrical Properties Dielectric test
1000 V r.m.s. for 5’ (core-core) 1000 V r.m.s. for 5’ (core-screen)
Impedance
120Ω
Capacitance
45 nF/km conductor to conductor 90 nF/km conductor to shield
CONSTRUCTION PARAMETERS RE-02Y(ST)H 1P18A Number & Nominal Diameter of Strands
Nominal Insulation Thickness
Nominal Sheath Thickness
Nominal Overall Diameter
Approx. Weight
AWG
No/mm
mm
mm
mm
kg/km
1
18
7/0.404
1.15
1.2
10.5
100
1
18
16/0.254
1.15
10.5
100
No.of pair ×
N
EIA/TIA 485
o p r i a . w
Standard
w w
Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4
24
c . s e l b a
m o
Wire Gange
Caledonian
Zero
Halogen Free IEC60754-1/ EN50267-2-1
c rt
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Flame Retardancy Fire Resistance NF C32-070-2.1(C2) IEC 60331 IEC60332-1-2/EN50265-2-1 /NF C 32070-2.3(CR1)
1.2
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073