Caledonian Airport Cables Closed circuit tv

Page 1

Caledonian ULV Cables www.airport-cables.com

-CCTV (Closed Circuit TV)

enquiry@airport-cables.com

Caledonian

CCTV (Closed Circuit TV) Video Cable KX6 LH-FR KX6 LH-FR

LSZH Outer Sheath

m o

Bare Copper PE+Fireproof Tape Insulation

c . s e l b a Bare Copper/Copper Clad Aluminum Screen

APPLICATIONS

The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.

STANDARDS

c rt

Basic design

MIL-C-17

Halogen Free

IEC 60754-1

No corrosive gas emission

IEC 60754-2

Minimum Smoke Emission

IEC 61034-1/2

Reduced Fire Propagation

IEC 60332-3C / NF C 32070-2.2 (C1)

Flame Retardance

IEC 60332-1 / NF C 32-070-2.1 (C2)

Fire Resistance

IEC 60331 / NF C 32070-2.3(CR1)

o p r i a . w

w w

CABLE CONSTRUCTION

Conductors: Bare Copper Insulation: Solid PE+fire resistant tape Screen: Bare copper/copper clad aluminum(CCA)(80% coverage) Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. ELECTRICAL PROPERTIES Impedance Nominal capacitance Velocity of propagation Insulation resistance Inner conductor resistance Outer conductor resistance Operating temperature range

75±5 Ohm 67 pF/m 66% >5000 Mohm.Km 87.5 Ohm/Km 21/32.5Ohm/Km 70 °C

ADDISON

21


ADDISON Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30°C - +70°C Temperature range during installation (mobile state): -5ºC - +60ºC Min. Bending Radius: 8 × Overall Diameter ATTENUATION For bare copper braid Frequency Attenuation Attenuation Mhz dB/100 m dB/ft 10 5.0 1.52 50 8.1 2.47 100 13 3.96 200 18.5 5.64 400 22.5 6.86 850 34.5 10.52 950 37.5 11.43 1000 45 13.72

Return Loss Frequency MHz 5-1000

o p r i a . w

w N w Standard

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

22

Caledonian

m o

Number & Nominal Diameter of Strands

Nominal Insulation Diameter

Nominal Sheath Thickness

Nominal Overall Diameter

No/mm 7/0.2

mm 3.7

mm 1.0

mm

Halogen Free IEC60754-1

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

KX6 LH-FR MIL-C-17

Attenuation dB/ft 2.47 3.96 5.64 6.86 10.52 11.43 -

c . s e l b a

c rt

Return Loss (dB >=20

CONSTRUCTION PARAMETERS Cable Code

Frequency Mhz 50 100 200 400 850 950 -

For CCA braid Attenuation dB/100 m 8.1 13 18.5 22.5 34.5 37.5 -

Zero

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

6.1


Caledonian ULV Cables www.airport-cables.com

-CCTV (Closed Circuit TV)

enquiry@airport-cables.com

Caledonian

CCTV (Closed Circuit TV) RS485 Data Cable RE-02Y(St)H 1P18A

RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

LSZH Outer Sheath Fireproof tape

m o

Stranded Tinned Copper PE Insulation

c . s e l b a

Overall AL/Polyester Tape With Tinned Copper Drain Wire

APPLICATIONS

The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

o p r i a . w

STANDARDS

c rt

Basic design Halogen Free

EIA/TIA 485 IEC 60754-1

No corrosive gas emission

IEC 60754-2

Minimum Smoke Emission

IEC 61034-1/2

w w

Reduced Fire Propagation

IEC 60332-3C / NF C 32070-2.2 (C1)

Flame Retardance

IEC 60332-1 / NF C 32-070-2.1 (C2)

Fire Resistance

IEC 60331-23 / NF C 32-070-2.3(CR1)

CABLE CONSTRUCTION Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Solid or foam PE compound Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Overall screen: Aluminum/ polyester tape with tinned copper drain wire. Fire Barrier: Fireproof Tape Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

23


ADDISON Electrical Properties Dielectric test

1000 V r.m.s. for 5’ (core-core) 1000 V r.m.s. for 5’ (core-screen)

Impedance

120Ω

Capacitance

45 nF/km conductor to conductor 90 nF/km conductor to shield

CONSTRUCTION PARAMETERS RE-02Y(ST)H 1P18A Number & Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

AWG

No/mm

mm

mm

mm

kg/km

1

18

7/0.404

1.15

1.2

10.5

100

1

18

16/0.254

1.15

10.5

100

No.of pair ×

N

EIA/TIA 485

o p r i a . w

Standard

w w

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

24

c . s e l b a

m o

Wire Gange

Caledonian

Zero

Halogen Free IEC60754-1/ EN50267-2-1

c rt

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Flame Retardancy Fire Resistance NF C32-070-2.1(C2) IEC 60331 IEC60332-1-2/EN50265-2-1 /NF C 32070-2.3(CR1)

1.2

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.