Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
flame Retardant Profibus DP IEC 61158 / EN 50170 SINEC L2(Siemens Profibus)
m o .c
s e l b a -c
aPPlIcaTIon:
Profibus DP cables are designed for field networks requiring fast, cyclic data exchange between controllers and field devices. This cable is usually referred as siemens profibus. This Profibus modification optimized with respect to velocity and low installation cost, Profibus DP is used as a replacement for conventional parallel data transmission with 24 V or 0 - 20 mA. With special design for the outer jacket, the cables are flexible and are suitable for operation at high temperature, protecting this cables from premature aging, while LSZH properties assure low smoke and corrosive gas in the event of a fire.
t r o
p r i a . w
fIRe PeRfoRMance
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
w w
Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; Halogen Free CEI 20-37/2-1 ; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; No Corrosive Gas Emission CEI 20-37/2-2 ; BS 6425-2* IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; Minimum Smoke Emission CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454
note: asterisk * denotes superseded standard.
ADDISON
121
ADDISON sTaTIc cables consTRUcTIon: Type Inner Conductor Inner Conductor Diameter Conductor Insulation Conductor Colors Stranding Element Shielding 1 Shielding 2
Static cables Plain copper 0.64mm (22AWG) Foam with a hard skin Red & green Synthetic bedding Aluminium foil
Shielding 3
Tinned copper wire braid – 60% optical coverage
Outer Jacket Material
PUR thermoplastic or thermosetting/ PVC/ PE/ LSHF
Outer Jacket Color
Violet/ Black
s e l b a -c
elecTRIcal DaTa: Characteristic Impedance @ 3-20MHz Conductor Resistance Test Voltage Operate Voltage Effective capacitance @ 1khz
w w
Data Rate
Attenuation:
122
t r o
p r i a . w
Caledonian
m o .c
9.6 Kbit/s 19.2 Kbit/s 93.75 Kbit/s 187.5 Kbit/s 500 Kbit/s 1.5 Mbit/s 12.0 Mbit/s 4MHz 9.6MHz 16MHz
150 Ω ± 10 Ω
57.1 Ohm/km max. 1.5KV Max: 350V 28.5nF/m 1200m 1200m 1200m 1000m 400m 200m 100m 22dB/100m 2.5dB/100m 42dB/100m
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
DynaMIc cables consTRUcTIon: Type
Dynamic cables
Inner Conductor:
Plain copper, 0.25mm²
Conductor Insulation
Foamed PE with a hard skin
Conductor Colors
Red & green
Stranding Element
Cores laid up with fillers
Core Wrapping
Polyester taped
Shielding 1
Aluminium foil
Shielding 2
Tinned copper wire braid – 60% optical coverage
Drain Wire
-
Outer Jacket Material
Polyurethane (PUR) sheath
Outer Jacket Color
Violet/ Black
s e l b a -c
elecTRIcal DaTa:
t r o
Characteristic Impedance @ 3-20MHz Conductor Resistance Test Voltage Working Voltage
a . w
Effective capacitance @ 1khz
w w
Data Rate
Attenuation
ri p
m o .c
150 Ω ± 10 Ω
84.0 Ohm/km max. 1.5KV
Max: 350V 28.5nF/m
9.6 Kbit/s
1200m
19.2 Kbit/s
1200m
93.75 Kbit/s
1200m
187.5 Kbit/s
1000m
500 Kbit/s
400m
1.5 Mbit/s
200m
12.0 Mbit/s
100m
4MHz
25dB/100m
9.6MHz
3dB/100m
16MHz
53dB/100m
ADDISON
123
ADDISON PHysIcal anD THeRMal PRoPeRTIes Temperature Range During operation (fixed state): -30°C - +70°C Temperature Range During Installation (Mobile state): -5°C - +60°C Minimum bending Radius: 8 X Overall Diameter
TecHnIcal DaTa: Static
Dynamic
Min. Bending Radius (Laying)
12 x OD mm
12 x OD mm
Operating Temp.Range, min.
-30 °C
-5 °C
Operating Temp.Range, max.
+70 °C
+70 °C
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1 EN 50268-1&2/NF C32-073
t r o
p r i a . w Zero
Low Toxicity NES 02-713/NF C 20-454
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
s e l b a -c
Halogen Free IEC60754-1 EN50267-2-1
w w
124
Caledonian
m o .c
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
flame Retardant Foundation Fieldbus ISA/SP-50 Profibus PA Type A
m o .c
s e l b a -c
aPPlIcaTIon
FoundationTM Field bus is used in intrinsically area,especially in the field of Process Automation. A single pair 18AWG Bi-Directional digital Fieldbus cable for type A applications (31.25 KBits/sec) available in PVC, LSHF and SWA versions. Anti-termite and anti-vermin foundation fieldbus cable is also available. With special design for the outer jacket, the cables are flexible and are suitable for operation at high temperature, protecting this cables from premature aging, while LSZH properties assure low smoke and corrosive gas in the event of a fire.
t r o
p r i a . w
fIRe PeRfoRMance
w w
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases
NES 02-713; NF C 20-454
note: asterisk * denotes superseded standard.
ADDISON
125
ADDISON consTRUcTIon: Foundation Fieldbus ISA/SP-50 Profibus PA Type A Tinned copper conductors 18(7)AWG 0.88mm² Polyolefin/Foamed PE with skin PE Aluminium /polyester foil (20AWG) tinned copper PVC White & Black Orange
Type Inner Conductor Conductor Insulation Stranding Element Shielding Drain Wire Outer Jacket Material Core Identification Sheath Colour
m o .c
PHysIcal anD THeRMal PRoPeRTIes Temperature Range During operation (fixed state): -30°C - +70°C Temperature Range During Installation (Mobile state): -5°C - +60°C Minimum bending Radius: 8 X Overall Diameter
s e l b a -c
elecTRIcal DaTa: Characteristic Impedance@31.25KHz Conductor resistance Working Voltage Test Voltage Nominal attenuation
t r o
p r i a . w
TecHnIcal DaTa:
Weight: Min. Bending Radius (Laying) Operating Temp.Range, min. Operating Temp.Range, max.
w w
100 Ω±20 Ω 24 Ohm/km @ 20°C Max: 300V 1.5KV 39 MHz<3 dB/km
approximately 85 kg/km/ 246 kg/km(SWA) 15 x OD mm - 25 °C +80 °C
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1 EN 50268-1&2/NF C32-073
Zero
Low Toxicity NES 02-713/NF C 20-454
126
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Caledonian
Halogen Free IEC60754-1 EN50267-2-1
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
flame Retardant foundation fieldbus Isa/sP-50 Type b bus cables
m o .c
s e l b a -c
aPPlIcaTIon
: FoundationTM Field bus is used in intrinsically area,especially in the field of Process Automation.A single pair 22AWG Bi-Directional digital Fieldbus cable for type B applications (31.25 KBits/sec) are available in PVC, LSHF and SWA versions. Anti-termite and anti-vermin foundation fieldbus cable is also available. With special design for the outer jacket, the cables are flexible and are suitable for operation at high temperature, protecting this cables from premature aging, while LSZH properties assure low smoke and corrosive gas in the event of a fire.
t r o
p r i a . w
fIRe PeRfoRMance
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
w w
Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases
NES 02-713; NF C 20-454
note: asterisk * denotes superseded standard.
cable consTRUcTIon
ADDISON
127
ADDISON Foundation Fieldbus ISA/SP-50 Type B Tinned copper conductors 22AWG 0.34mm² Polyolefin/Foamed PE with skin PE Aluminium /polyester foil (22AWG) tinned copper PVC White & Black Orange
Type Inner Conductor Conductor Insulation Stranding Element Shielding Drain Wire Outer Jacket Material Core Identification Sheath Colour
m o .c
PHysIcal anD THeRMal PRoPeRTIes Temperature Range During operation (fixed state): -30°C - +70°C Temperature Range During Installation (Mobile state): -5°C - +60°C Minimum bending Radius: 8 X Overall Diameter
s e l b a -c
elecTRIcal DaTa: Characteristic Impedance@31.25Hz Conductor resistance
130 Ω±20 Ω
t r o
Working Voltage Test Voltage
p r i a . w
Nominal attenuation
TecHnIcal DaTa: Weight:
56.0Ohm/km @ 20°C 300V
1.5KV
39 MHz
approximately 53 kg/km/ 213 kg/km(SWA)
w w
Min. Bending Radius (Laying)
15 x OD mm
Operating Temp.Range, min.
- 25 °C
Operating Temp.Range, max.
+80 °C
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) EN 50268-1&2/NF C32-073 IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1
Zero
Low Toxicity NES 02-713/NF C 20-454
128
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Caledonian
<3 dB/km
Halogen Free IEC60754-1 EN50267-2-1
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
flame Retardant foundation fieldbus Isa/sP-50 High speed bus cables
m o .c
s e l b a -c
aPPlIcaTIon
FoundationTM Field bus is used in intrinsically area,especially in the field of Process Automation. A high speed single pair 22AWG Bi-Directional digital Fieldbus cable for 1.0 & 2.5MBit/sec applications available in PVC, LSHF and SWA versions. Anti-termite and anti-vermin foundation fieldbus cable is also available. With special design for the outer jacket, the cables are flexible and are suitable for operation at high temperature, protecting this cables from premature aging, while LSZH properties assure low smoke and corrosive gas in the event of a fire.
fIRe PeRfoRMance
t r o
p r i a . w
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; Halogen Free CEI 20-37/2-1 ; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; No Corrosive Gas Emission CEI 20-37/2-2 ; BS 6425-2* IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; Minimum Smoke Emission CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454
w w
note: asterisk * denotes superseded standard.
cable consTRUcTIon Type Inner Conductor Conductor Insulation Stranding Element Shielding
Foundation Fieldbus ISA/SP-50 High Speed Tinned copper conductors 22(7)AWG 0.34mm² Foamed polyolefin Aluminium /polyester foil
ADDISON
129
ADDISON Drain Wire Outer Jacket Material Core Identification Sheath Colour
(22AWG) tinned copper PVC White & Black Orange
elecTRIcal DaTa: Characteristic Impedance@31.25Hz Conductor resistance Working Voltage Test Voltage
150 Ω±10 Ω 56.0 Ohm/km @ 20°C 300V 1.5KV
m o .c
39 MHz<3 dB/100m
Attenuation
PHysIcal anD THeRMal PRoPeRTIes
s e l b a -c
Temperature Range: -30°C - +75°C Minimum bending Radius: 815 X Overall Diameter
TecHnIcal DaTa:
approximately 65 kg/km/ 287 kg/km(SWA)
t r o
Weight Min. Bending Radius (Laying) Operating Temp.Range, min.
p r i a . w
Operating Temp.Range, max.
w w
15 x OD mm
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1 EN 50268-1&2/NF C32-073
Low Toxicity NES 02-713/NF C 20-454
130
Zero
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Caledonian
Halogen Free IEC60754-1 EN50267-2-1
enquiry to sales@airport-cables.com
- 25 °C +80 °C
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
flame Retardant asI bus cables
Plain Copper Wire Braid Screen PE Tinned Copper Binder LSZH Outer Sheath
m o .c
s e l b a -c
aPPlIcaTIon
: ASI is standardized Europe-wide in EN 50295 and internationally in IEC 62026-2.Network system for the lowest field level (binary sensors and actuators). Data and energy are transmitted between control unit and peripherals via an unscreened, geometrically coded two-core flat cable (pole safe). The conductor is contacted by piercing technology within the ASI-modules. With special design for the outer jacket, the cables are flexible and are suitable for operation at high temperature, protecting this cables from premature aging, while LSZH properties assure low smoke and corrosive gas in the event of a fire.
t r o
p r i a . w
fIRe PeRfoRMance
w w
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases
NES 02-713; NF C 20-454
note: asterisk * denotes superseded standard.
ADDISON
131
ADDISON cable consTRUcTIon Type/Area of Application
Actuator Sensor Interface
Cable Construction
2x1.5 mm2
Inner Conductor Diameter
Copper, tinned
Conductor Insulation
Rubber Compound /TPE
Conductor Colors
Blue, brown
Stranding Element
-
Shielding
-
Shielding 2
-
Total Shielding
-
Outer Jacket Material
EPDM/PUR/ PVC/PE
Outer Jacket Color
Yellow /Black
elecTRIcal DaTa:
p r i a . w
Insulation Resistance Working Voltage Test Voltage
s e l b a -c
t r o
Conductor Resistance:
w w
m o .c
27.4 Ohm/km max.
1.00 GOhm x km min. Max: 300 V 1.0 KV at 15 min.
TecHnIcal DaTa:
approximately 57.0 kg/km
Weight
132
Min. Bending Radius (Laying)
6 x OD mm
Operating Temp.Range, min.
- 40 째C
Operating Temp.Range, max.
+85 째C
Caledonian
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
PHysIcal anD THeRMal PRoPeRTIes Temperature Range During operation (fixed state): -30째C - +70째C Temperature Range During Installation (Mobile state): -5째C - +60째C Minimum bending Radius: 8 X Overall Diameter
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1 EN 50268-1&2/NF C32-073
m o .c
Zero
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Low Toxicity NES 02-713/NF C 20-454
s e l b a -c
Halogen Free IEC60754-1 EN50267-2-1
t r o
p r i a . w
w w
ADDISON
133
ADDISON flame Retardant communication Plastic optical fiber cables
LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper
LSZH Inner Sheath
m o .c
Tinned Copper Drain Wire Braid or Wire Armoured
s e l b a -c
aPPlIcaTIon
1. Signal transmission of sensors; 2. High speed data transmission; 3. Industrial control data links; 4. Military communication; 5. Proprietary LANs or Access Network; 6. Multi-media data link and plant control in vehicles and airplanes;
t r o
p r i a . w
fIRe PeRfoRMance
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
w w
Reduced Fire Propagation EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free
No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* NES 02-713; NF C 20-454
note: asterisk * denotes superseded standard.
cable consTRUcTIon Plastic Optical Fiber Cable, also named polymer optical fiber, which is used for lighting and communications: Cladding Material: Fluorinated Polymer
134
Caledonian
enquiry to sales@airport-cables.com
Caledonian
flame Retardant bus cables www.airport-cables.com
www.caledonian-tech.net
Jacketing Material: PE or PVC Optical Instruction: Step Index Model Numerical Aperture: 0.5 Allowable Bend Radius: No less than ten times of optical fiber diameter Core Refractive Index: 1.492
elecTRIcal PRoPeRTIes 1. Attenuation <0.18dB/m @ 650nm; 2. Theoretic bandwidth of 10~20MHz. 50m(Numerical aperture 0.5), 100~200MHz. 50m(Numerical aperture 0.3); 3. Diameter allowance ± 3% in actual production; 4. Working temperature: --454~80 Celsius Degrees; 5. Jacketing material: PE or PVC
m o .c
s e l b a -c
PHysIcal anD THeRMal PRoPeRTIes
Temperature range during operation (fixed state): -30°C - +75°C Minimum bending radius: 15 x Overall Diameter
t r o
TecHnIcal DaTa:
Model
Fiber Dia. (mm)
Jacketing Materials
Max. Attenuation (dB/m)
Working Dia. Spool Length N. A Temperature Allowance (m) (Celsius Degrees) (± %)
CC2-500 CC2-750 CC2-1000
0.5 0.75 1.0
PE PE PE
0.18 0.18 0.18
0.5 0.5 0.5
w w
p r i a . w
-45~80 -45~80 -45~80
1000/6000 2700 1500/2500
± 3% ± 3% ± 3%
Low Smoke Emission Flame Retardancy Reduced Fire Propagation IEC 61034-1&2 NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24/EN50266-2-4IEC60332-1-2/EN50265-2-1 EN 50268-1&2/NF C32-073
Zero
Low Toxicity NES 02-713/NF C 20-454
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074
Halogen Free IEC60754-1 EN50267-2-1
ADDISON
135