Caledonian Cables IEC60502-1
XLPE Insulation
600/1000V, XLPE Insulated Cables according to IEC 60502-1 Application: These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction: Conductors
Copper conductor, round standed, Class 2 to IEC 60228, BS EN 60228.
Insulation
XLPE material and thickness shall be as per IEC 60502 rated for 90째C continuous operation.
Colour Code
Colour Code (1) : 3 Cores
:
Red, Yellow, Blue
4 Cores
:
Red, Yellow, Blue, Black
Colour Code (2) : 3 Cores
:
Brown, Black, Grey
4 Cores
:
Blue, Brown, Black, Grey
Assembly /
Three or Four insulated conductors are laid-up together with non-hygroscopic fillers
Inner Sheath
(xtruded layer of PVC.
www.caledonian-cables.co.uk
www.caledonian-cables.net
17
Addison Cables IEC60502-1
XLPE Insulation
Armour Galvanized Steel Wires applied helically over the bedding as per IEC 60502 Outer Sheath Extruded PVC Type ST2 as per IEC 60502-1 Fire
Cables can be supplied with special flame retardant PVC outer sheath to comply with
Performance
the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24
f
.
S
Cable Parameters:
XLPE insulation Plain copper conductor PVC jacket
Nominal Cross Section mm² 1x1.5 1x2.5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95
18
Diameter of Conductor (Approx.) mm 1.6 2 2.6 3.1 4 5 6.3 7.4 8.8 10.6 12.4
Nominal Insulation Thickness mm 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1 1.1 1.1
Nominal PVC Sheath Thickness mm 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.5
www.addison-tech.com
Overall Diameter (Approx.) mm 6 6.5 7 7.5 8.5 9.5 11.5 12 13 15 17
Weight of Cable (Approx.) Kg/Km 50 70 80 110 150 215 315 415 555 760 1025
www.addison-cables.com
Addison Cables IEC60502-1
XLPE Insulation
Nominal Cross Section mm²
Diameter of Conductor (Approx.) mm
Nominal Insulation Thickness mm
Nominal PVC Sheath Thickness mm
Overall Diameter (Approx.) mm
Weight of Cable (Approx.) Kg/Km
4x120
14
1.2
2.3
40.5
5320
4x150
15.5
1.4
2.4
44.5
6510
4x185
17.4
1.6
2.6
51
8050
4x240
20.3
1.7
2.8
58.5
10520
4x300
22.7
1.8
3
64.5
13130
4x400
25.4
2
3.3
73.5
16850
Multi-cores(unarmoured) Plain copper conductor XLPE insulation PVC jacket
22
Nominal Cross Section mm²
Diameter of Conductor (Approx.) mm
Nominal Insulation Thickness mm
Nominal PVC Sheath Thickness mm
Overall Diameter (Approx.) mm
Weight of Cable (Approx.) Kg/Km
5x1.5
1.6
0.7
1.4
14
260
7x1.5
1.6
0.7
1.4
15
310
10x1.5
1.6
0.7
1.4
18
395
12x1.5
1.6
0.7
1.4
18.5
440
14x1.5
1.6
0.7
1.4
19
485
19x1.5
1.6
0.7
1.4
21
600
21x1.5
1.6
0.7
1.4
22
650
24x1.5
1.6
0.7
1.4
24
730
30x1.5
1.6
0.7
1.4
25
860
40x1.5
1.6
0.7
1.4
28
1080
48x1.5
1.6
0.7
1.4
30
1250
61x1.5
1.6
0.7
1.4
33
1570
5x2.5
2
0.7
1.4
15
330
7x2.5
2
0.7
1.4
16
400
10x2.5
2
0.7
1.4
19.5
515
12x2.5
2
0.7
1.4
20
580
14x2.5
2
0.7
1.4
21
650
www.addison-tech.com
www.addison-cables.com
Caledonian Cables IEC60502-1
XLPE Insulation Nominal Insulation thickness mm
Nominal bedding thickness mm
Nominal Steel Wire dia. mm
Nominal Sheath thickness mm
Approx. Overall Diameter mm
Approx. Weight
mm²
Approx Conductor Diameter mm
3x1.5
1.6
0.7
1.2
0.9
1.8
15
380
3x2.5
2
0.7
1.2
0.9
1.8
15.5
400
3x4
2.6
0.7
1.2
0.9
1.8
16.5
460
3x6
3.1
0.7
1.2
0.9
1.8
3x10
4
0.7
1.2
0.9
1.8
19.5
750
3x16
5
0.7
1.2
1.25
1.8
22.5
1000
3x25
6.3
0.9
1.2
1.6
1.8
26
1510
3x35
7.4
0.9
1.2
1.6
1.8
28
1950
3x50
8.8
1
1.2
1.6
1.9
32
2350
3x70
10.6
1.1
1.2
2
2
35
3230
3x95
12.4
1.1
1.2
2
2.1
39
4050
3x120
14
1.2
1.2
2
2.3
43
5230
3x150
15.5
1.4
1.4
2.5
2.4
47
6750
3x185
17.4
1.6
1.4
2.5
2.6
52
8230
3x240
20.3
1.7
1.5
2.5
2.7
59
10510
3x300
22.5
1.8
1.6
2.5
2.9
64
13210
3x400
25.4
2
1.6
2.5
3.2
74
16100
Nominal Area
18
Kg/Km
540
Three cores+1(Galvanized steel wire armoured) PVC bedding XLPE insulation Plain copper conductor Galvanized steel wire armour PVC jacket
3x 16/10
Approx Conductor Diameter (3) (1) mm mm 5 4
Nominal Insulation thickness (3) (1) mm mm 0.7 0.7
3x 25/16
6.3
5
0.9
3x 35/16
7.4
5
3x 50/25
8.8
3x 70/35 3x 95/50
Nominal Area mm²
Nominal bedding thickness
Nominal Steel Wire dia.
Nominal Sheath thickness
Approx. Overall Diameter
Approx. Weight
mm
mm
mm
mm
Kg/Km
1
1.6
1.8
25.5
1550
0.7
1
1.6
1.8
27.5
2010
0.9
0.7
1
1.6
1.8
29
2375
6.3
1
0.9
1
1.6
2
33
3100
10.6
7.4
1.1
0.9
1.2
2
2.1
38
4290
12.4
8.8
1.1
1
1.2
2
2.3
43.5
5540
www.caledonian-cables.co.uk
www.caledonian-cables.net
25
Addison Cables IEC60502-1
XLPE Insulation
3x120/70
Approx Conductor Diameter (3) (1) mm mm 14 10.6
Nominal Insulation thickness (3) (1) mm mm 1.2 1.1
3x150/70
15.5
10.6
1.4
3x185/95
17.4
12.4
3x240/120
20.3
3x300/150 3x400/185
Nominal Area mm²
Nominal bedding thickness
Nominal Steel Wire dia.
Nominal Sheath thickness
Approx. Overall Diameter
Approx. Weight
mm
mm
mm
mm
Kg/Km
1.2
2
2.4
49
7150
1.1
1.4
2.5
2.5
52
8330
1.6
1.1
1.4
2.5
2.7
57.2
10110
14
1.7
1.2
1.6
2.5
3
64
12740
22.7
15.5
1.8
1.4
1.6
2.5
3
69.8
15430
25.4
17.4
2
1.6
1.6
3.15
3.3
78.6
19990
Four cores(Galvanized steel wire armoured) PVC bedding Plain copper conductor XLPE insulation Galvanized steel wire armour PVC jacket Nominal Area mm²
26
Approx Nominal Conductor Insulation Diameter thickness mm mm
Nominal bedding thickness mm
Nominal Steel Wire dia. mm
Nominal Sheath thickness mm
Approx. Overall Diameter mm
Approx. Weight Kg/Km
4x1.5
1.6
0.7
1
0.9
1.8
15
415
4x2.5
2
0.7
1
0.9
1.8
17.
490
4x4
2.6
0.7
1
0.9
1.8
19
600
4x6
3.1
0.7
1
0.9
1.8
20
730
4x10
4
0.7
1
1.25
1.8
23
970
4x16
5
0.7
1
1.6
1.8
26
1520
4x25
6.3
0.9
1
1.6
1.8
29
2010
4x35
7.4
0.9
1
1.6
1.9
31
2560
4x50
8.8
1
1
1.6
2.1
36
3350
4x70
10.6
1.1
1.2
2
2.2
40
4680
4x95
12.4
1.1
1.2
2
2.4
44
5710
4x120
14
1.2
1.4
2.5
2.5
50
7500
4x150
15.5
1.4
1.4
2.5
2.6
55
9010
4x185
17.4
1.6
1.4
2.5
2.8
61
10820
4x240
20.3
1.7
1.6
2.5
3.1
69
13630
4x300
22.7
1.8
1.6
2.5
3.2
75
16820
4x400
25.4
2
1.8
3.15
3.4
83
22230
www.addison-tech.com
www.addison-cables.com