Caledonian ULV Cables-PAS (Public Address System) www.airport-cables.com

enquiry@airport-cables.com

Caledonian

PAS (Public Address System)

Loudspeaker Cable FFX200 05mRZ1-R/F 2G1.0 FFX200 05mRZ1-R 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 2) FFX200 05mRZ1-F 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 5)

m o

Plain Annealed Copper

c . s e l b a Mica+XLPE Insulation LSZH Outer Sheath

APPLICATIONS

The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings.

o p r i a . w

STANDARDS

c rt

Basic design

BS 7629-1

Halogen Free

IEC 60754-1

No corrosive gas emission

IEC 60754-2

Minimum Smoke Emission

IEC 61034-1/2

Reduced Fire Propagation

IEC 60332-3C / NF C 32070-2.2 (C1)

Flame Retardance

IEC 60332-1 / NF C 32-070-2.1 (C2)

Fire Resistance

IEC 60331 / NF C 32070-2.3(CR1)

w w

VOLTAGE RATING 300/500V

CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Mica glass tape covered by extruded cross-linked XLPE compound. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

25


ADDISON Electrical PROPERTIES Dielectric test:

2000 V r.m.s. x 5’ (core/core)

Insulation resistance

1000 MΩ x km (at 20°C)

Short circuit temperature

250°C

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30°C – +90°C Temperature range during installation (mobile state): -20°C – +50°C Minimum bending radius: 8 × Overall Diameter

FFX200 05mRZ1-R 2G1.0 FFX200 05mRZ1-F 2G1.0 Nominal Cross No.of core Sectional Area mm2

Number & Nominal Diameter of Strands No/mm

o p r N .ai w w w 2

1.0

7/0.44

2

1.0

32/0.2

BS 7629-1

Zero

Standard

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

26

Caledonian

Halogen Free IEC60754-1

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Nominal Insulation Thickness

c rt mm 0.5 0.5

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

m o

c . s e l b a

CONSTRUCTION PARAMETERS

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

mm

mm

kg/km

0.5

5.3

47

0.5

5.3

47

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073


Caledonian ULV Cables-PAS (Public Address System) www.caledonian-cables.co.uk

www.addison-cables.com

Caledonian

PAS (Public Address System)

RS485 Data Cable RE-02Y(St)H 1P18A RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

LSZH Outer Sheath Fireproof tape

m o

Stranded Tinned Copper PE Insulation

c . s e l b a

Overall AL/Polyester Tape With Tinned Copper Drain Wire

APPLICATIONS

c rt

The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

o p r i a . w

STANDARDS Basic design Halogen Free

EIA/TIA 485 IEC 60754-1

No corrosive gas emission

IEC 60754-2

Minimum Smoke Emission

IEC 61034-1/2

Reduced Fire Propagation

IEC 60332-3C / NF C 32070-2.2 (C1)

Flame Retardance

IEC 60332-1 / NF C 32-070-2.1 (C2)

Fire Resistance

IEC 60331-23 / NF C 32-070-2.3(CR1)

w w

CABLE CONSTRUCTION Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Solid or foam PE compound Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Overall screen: Aluminum/ polyester tape with tinned copper drain wire. Fire Barrier: Fireproof Tape. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

27


ADDISON Electrical Properties Dielectric test

1000 V r.m.s. for 5’ (core-core) 1000 V r.m.s. for 5’ (core-screen)

Impedance

120Ω

Capacitance

45 nF/km conductor to conductor 90 nF/km conductor to shield

m o

Physical AND THERMAL PROPERTIES

c . s e l b a

Temperature range during operation (fixed state): -30°C – +90°C Temperature range during installation (mobile state): -20°C – +50°C Minimum bending radius: 8 × Overall Diameter CONSTRUCTION PARAMETERS RE-02Y(ST)H 1P18A

c rt

Wire Gange

Number & Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

AWG

No/mm

mm

mm

mm

kg/km

1

18

7/0.404

1.15

1.2

10.5

100

1

18

16/0.254

1.15

1.2

10.5

100

No.of pair

o p r i a . Nw w w EIA/TIA 485

Zero

Standard

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

28

Caledonian

Halogen Free IEC60754-1

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073