CANNER SLIPWAY AREA DEVELOPMENT

Page 1

CANNER SLIPWAY AREA DEVELOPMENT

DOTTED RED LINE INDICATES PROPOSED DEVELOPMENT AREA

N

N

NEWLYN HARBOUR AUTHORITY

Tarmac car park area

CLIENT:

RNLI Workshop Building

Concrete slab around RNLI Workshop

Raised concrete quayside

Above: Plan on CANNER SLIPWAY AREA Scale 1:500

A 1

CANNER SLIPWAY BUSINESS PARK - 1. NEWLYN TOWN & EXISTING SITE PLAN Scale: As shown @ A3 Paper size

Mean High Water Spring Level (MHWS)

GENERAL ARRANGEMENT PLANS

Scale 1:5000

DRAWING TITLE:

Mean Low Water Spring Level (MLWS)

Above: Plan on Newlyn Town

DRAWING NAME:

Main road (pavements not shown)

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

RNLI Current workshop building and area for potenJal development

CANNER SLIPWAY AREA DEVELOPMENT

DATE: 23:08:17

Cobbled slipway

DRAWN BY: G Duff

CONSULTANT:

Hardcore compacted rough ground

Sheet 1 of 6 REV: 02


14564 mm

m

Scale 1:1000

Building footprint: 8 x 120m2 = 960m2

Building footprint: 1,713m2 40488 mm

17500 mm

4000 mm

6000 mm 6000 mm

15 62 9 m

60 00 m

5000 mm

m

m

Above: Building option 3 - Single U building Scale 1:5000

A 2

Above: Building option 4 - Single unit sub-divided Scale 1:5000

CANNER SLIPWAY BUSINESS PARK - 2. NEW SLAB & BUILDING OPTIONS Scale: As shown @ A3 Paper size

DRAWING TITLE:

DRAWING NAME:

Vehicle access on waterside front

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

20770 mm

10759 mm

GENERAL ARRANGEMENT PLANS

Building footprint: 1,631m2

Above: Building option 2 - 2 Buildings opposite

DRAWN BY: G Duff

Scale 1:1000

CANNER SLIPWAY AREA DEVELOPMENT

Above: Building option 1 - Single U building

Light vehicle and pedestrian access around building perimeter

DATE: 23:08:17

m 2 m 794

Scale 1:1000

21 49 7 m

31 50 m

m

m

Light vehicle and pedestrian access around building perimeter

m

49 04 8 m

Above: Plan showing proposed new slab area

3150 mm

3150 mm

CLIENT:

14564 mm

CONSULTANT:

Building footprint: 492m2 + 803m2 =1,295m2

64773 mm

Slab area: 2,228m2

Building footprint: 1,582m2

31 50 m

33448 mm

m 47382 m

NEWLYN HARBOUR AUTHORITY

CANNER SLIPWAY AREA DEVELOPMENT

Above: Building option 5 - 7 Units Scale 1:1000

Sheet 2 of 6 REV: 02


CONSULTANT:

CLIENT:

NEWLYN HARBOUR AUTHORITY

CANNER SLIPWAY AREA DEVELOPMENT

Above: Photo of existing area from the top of the slipway viewing towards the marina

DRAWN BY: G Duff

CANNER SLIPWAY AREA DEVELOPMENT GENERAL ARRANGEMENT PLANS

DRAWING TITLE:

DRAWING NAME:

Above: Building option 5 seen from a similar viewpoint

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

DATE: 23:08:17

Not to scale

Not to scale

A 3

CANNER SLIPWAY BUSINESS PARK - 3. VIEW OF EXISTING AREA & OPTION 5 BUILDING FROM TOP OF SLIPWAY Scale: As shown @ A3 Paper size

Sheet 3 of 6 REV: 02


CANNER SLIPWAY AREA DEVELOPMENT VIEW 2

Solar panels on south side of each unit roof

DRAWN BY: G Duff DRAWING TITLE:

DRAWING NAME:

GENERAL ARRANGEMENT PLANS

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

VIEW 3

CANNER SLIPWAY AREA DEVELOPMENT

VIEW 3

DATE: 23:08:17

CONSULTANT:

CLIENT:

NEWLYN HARBOUR AUTHORITY

VIEW 1 (shadows shown on all views as 8th June at 13:30)

VIEW 2

A 4

CANNER SLIPWAY BUSINESS PARK - 4. ALTERNATIVE VIEWS OF OPTION 5 BUILDING LAYOUT Scale: As shown @ A3 Paper size

Above: Plan on site showing Views Not to scale

VIEW 1

Sheet 4 of 6 REV: 02


CANNER SLIPWAY AREA DEVELOPMENT 6796 mm

5000 mm

Longest pile 8100mm

Scale 1:200

10kW of solar on each unit south facing side of roof

Davit crane on corner of pile wall

A 5

CANNER SLIPWAY BUSINESS PARK - 5. ORTHOGRAPHIC ELEVATIONS ON DEVELOPMENT Scale: As shown @ A3 Paper size

CANNER SLIPWAY AREA DEVELOPMENT GENERAL ARRANGEMENT PLANS

Piles shown stepping up in bays along the wall face as the penetraVon required reduces.

DRAWING TITLE:

Scale 1:200

DRAWING NAME:

Above: Elevation on development perpendicular to pile face running alongside the existing slipway

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

6000 mm

DATE: 23:08:17

8 No Total x 120m2 individual factory units Shown with roller shuRers on both ends

DRAWN BY: G Duff

Above: Elevation on development from marina perpendicular to long pile face

CONSULTANT:

CLIENT:

NEWLYN HARBOUR AUTHORITY

1000 mm

Spacings between units to enable vehicle access if necessary

Sheet 5 of 6 REV: 02


1. Project Name confirmed as ‘Canner Slipway Development’. All drawing sheet names and >tles amended to reflect this development name.

2. Various other views on this layout amended appropriately based on new Op>on 5 buildings layout. 3. Solar panels shown on all south facing roofs. Approximately 10kW of solar possible on each unit.

CANNER SLIPWAY AREA DEVELOPMENT

A 6

CANNER SLIPWAY BUSINESS PARK - 6. TRACKING DESIGN CHANGES Scale not applicable

DRAWING TITLE:

DRAWING NAME:

GENERAL ARRANGEMENT PLANS

GD7-NEWLYN-CSW-DRA-001-Rev02

PROJECT:

DATE: 23:08:17

4. Vans shown parked on the south area of the plot. Addi>onal trucks shown on the views to demonstrate space for this vehicle type.

DRAWN BY: G Duff

1. Buildings layout Op>on 5 modified to include 3 separate building blocks made up of the general single 120m2 unit size. Buildings moved around to suit client’s expected use. Vehicle a c c e s s a r o u n d t h e q u a y w a l l maintained.

CLIENT:

REVISION 2 - Following client comments 14:08:17

CONSULTANT:

REVISION 1 - Following client review 13:06:17

NEWLYN HARBOUR AUTHORITY

CANNER SLIPWAY AREA DEVELOPMENT

Sheet 6 of 6 REV: 02


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.