Eaton Series 5900 Chopper Plasma Power Supply

Built for rugged conditions. The Eaton Chopper Plasma Power Supplies 5900 Series are high performance sources for powering plasma torches and DC arc furnaces. Dependability is achieved through the use of conservatively rated magnetics and power modules. Faster system response achieved by switching power modules results in greater arc stability and an increase of efficiency, high power factor, low line harmonics and low maintenance. With different preferences, this product can be customer specified to exact system requirments.

High performance

Multiple torch configurations

Faster system response

Greater arc stability

Economically advantageous

otal system power can be T limited to the maximum acceptable load power

Reduces the overall installation footprint

Energy efficient When compared to traditional phase controlled topologies. •

Reduced transformer harmonics

igher operating H power factor

Industrial construction With rugged enclosures, this product is built with a sturdy base for fork or overhead lifting. •

Typically single piece construction for systems under 5MW reduces on site assembly time and expense

Dust tight liquid cooled construction enables the power supply to be installed in harsh environments

Considerable system savings

High track record Our team of engineers and technicians have over a century of combined experience with plasma power supplies.


Customer Specification Sheet Access this sheet online at http://www.eaton.com/5900 System Inputs

Physical Constraints (if Any)

3 Phase Line Voltages

________ V nom.

Width ________ in./mm

Line Voltage Variance

________ %+/-

Height ________ in./mm

Ground Neutral Supply

________ Yes/No

Depth ________ in./mm

Frequency

________ Hz.

Enclosure Type

Max. 3 Phase Fault

________ MVA

Outdoor

Min. 3 Phase Fault

________ MVA

Weight ________

Maximum VTHD

________ IEEE519 STD

Color ________

Rectification Pulse #

________ 6,12,18,24…

Amb. Temp. Range

Auxiliary Power Voltage

________ V

Input Switchgear Required ________ Yes/No

Indoor

________

Transformer Primary BIL

________ kV

Winding Temp Rise

________ °C

Core and Coil Cooling:

System Outputs Application ________

Convection

Outputs per Transformer

________

Heat Exchanger:

Max. Current

________ Amps

Max. Voltage

________ Volts

Elevation ________ m.

Air

Forced

Water

Convection

Forced

Min. Voltage @ Max. Current________ Volts

Atmosphere/Contaminates ____________________

Max. Power ( all outputs ) ________ Watts

Temperature:

Load Curves Attached

________ Yes/No

Regulation loop

________ Current/Power

Min.

Max.

________ Ave.

Instrumentation

Semiconductor Redundancy ________ Yes/No

Primary Protection CT’s

________ Yes/No

Chopper Input Isolation Sw. ________ Yes/No

Primary Metering CT’s

________ Yes/No

Output Isolation Switch

________ Yes/No

Meter and Protection Relay ________ Yes/No Temp. Gauges and Sw.’s

Water System

Flow (Minimum)

Other Required Features

Min. Differential Pressure ________ Max. Input Pressure

________

Test Pressure

________

Temperature Range

________ °C

Water Source

________

Fouling Factor

________

Freeze Protection

________ Yes/No

Water System Redundancy Pump

________ Yes/No

________ Yes/No

Heat Exch.

© 2012 Eaton Corporation All Rights Reserved Printed in USA Publication Number PA04001002E / 3PC August 2012