HANDICAP ACCESSIBILITY DIAGRAMS - DOORS X
6" MAX.
CLEAR FLOOR SPACE AT LAVATORIES
66" MIN.
40" MAX.
34" MAX.
29" MIN.
Clear Floor Space
Protected Piping
48" MIN.
LAVATORY CLEARANCES
18" (24" pref'd)
60" min
30" MIN.
27" MIN.
9"
Clear Floor Space
48" MIN.
17" MIN.
4. Accessible routes to be provided between facilities, providing a minimum of 36 inches in width along the accessible route, and a minimum of 32 inches in width at doorways.
Note: Y=48" minimum if door has both a closer and a latch.
Note: X=12" if door has both a closer and a latch.
Lav.
19" MAX.
Lav.
3. Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist.
CLEAR FLOOR SPACE AT WATER CLOSETS
24" min Push Side
PLUMBING NOTES 1. 2. 3. 4.
PLUMBING FIXTURE SCHEDULE
All plumbing and gas piping work shall be installed in strict accordance with the requirements of Article 16 and Reference Standard RS 16 of the 2014 NYC Building Code.
1.
Plumbing fixtures shall be of type and manufacture approved for use in New York City, and shall bear BSA approval.
2.
All gas-fired equipment to be A.G.A. or M.E.A. approved. Plumbing Contractor to examine proposed layout with regard to existing field conditions, and shall notify Architect of any discrepancies between assumed field conditions and those encountered during construction. Plumbing contractor shall inform Architect of any revisions to plan which shall be necessary, based on conditions uncovered in the field, in order to install all fixtures, equipment and piping in strict accordance with the requirements of the NYC Building and Plumbing codes.
5.
Plumbing Contractor shall arrange and obtain inspections and required sign-offs.
6.
Remove or relocate all plumbing as required. Removed pipes shall be cut to a point of concealment behind or below finish surfaces, and shall be properly capped or plugged.
7.
All soil & vent piping shall be "no hub" cast iron.
8.
All branch piping of 4" Ø or greater shall be pitched 1/8" per foot or less than 1/4" per foot. All vent piping shall be pitched to drain.
9.
All hot and cold water piping shall be copper tubing type "L" with 95-5 soldered joints.
X
Above Finished Floor Access Panel Adjacent Air Conditioner Air Handling Unit Aluminum Architectural Block Bottom of Building Cabinet Ceiling Ceiling Height Centerline Ceramic Tile Closet Column Concrete Concrete Masonry Unit Continuous Control Joint Diameter Drinking Fountain Down Elevation Equal Existing Expansion Joint Exterior Fire Extinguisher Fire Extinguisher Cabinet
Reference A-500 for Plumbing Fixture tags. P.1
KOHLER WIDESPREAD BATHROOM SINK FAUCET (K-14406-4)
P.2
KOHLER WALL-MOUNTS BATHROOM SINK (K-2053)
P.3
KOHLER ONE-PIECE TOILET (K-3828)
P.4
FIAT MOP SINK (TSB-100)
P.5
AMERICAN STANDARD UTILITY FAUCET (8344.212)
PLUMBING RISER DIAGRAMS
Pull Side
24" min Pull Side
4"
TO GO
2.
2"
101
WC (ADA)
103
BAR
1 - 1/2" 2"
1 - 1/2" W.C.
2" 3"
3.
1 - 1/2" W.C.
LAV.
UNDERMOUNT SINK
2"
3"
4"
C01
104
2"
1 - 1/2"
LAV.
UNDERMOUNT SINK
CLEANOUT
WC (ADA)
2"
1 - 1/2"
FIRST FLOOR
102
2" 3"
3"
2" 3"
2"
CLOSET
C03
2"
1 - 1/2" NOTE: PLUMBING FIXTURES AT PREP AREA TO BE CONFIRMED BY KITCHEN CONSULTANT
1 - 1/2" W.C.
LAV.
MOP SINK
CELLAR TO SEWER AT SMITH STREET
3"
CLEANOUT 2"
3"
2"
CLEANOUT
CLEANOUT
3"
Scope of Work:
A new stair, new walls, new doors, new plumbing fixtures and fitting, new electrical work (including new lighting fixtures), a new finishes.
Location:
191 Smith Street, Brooklyn, NY 11231
Tax Block and Lot:
Block: 397, Lot: 07
Landmark:
NO
Zoning District: Overlay(s):
R6B Residential C2-4
Zoning Map:
16c 30132806F
Note: X=36" minimum if Y=60" X=42" minimum if Y=54"
Note: Y=54" minimum if door has a closer.
HINGE SIDE APPROACHES - SWING DOORS
LATCH SIDE APPROACHES - SWING DOORS
Certificate of Occupancy:
Plastic Laminate Plywood Quantity Radius Required Reinforcing Right Hand Roof Drain Rough Opening Schedule Section Similar Square Foot Stainless Steel Steel Structural / Structure Suspended Telephone Top of Top of Catch Basin Top of Curb Typical Verify In Field Vertical Vinyl Composite Tile Utility Water Closet With Without Wood
INTERIORS
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
DRAWING INDEX A.F.F. A.P. ADJ. A.C. A.H.U. ALUM. ARCH. BLK. B.O. BLDG. CAB. CLG. CLG. HT. C.L. C.T. CL. COL. CONC. C.M.U. CONT. C.J. DIA. D.F. DN ELEV. EQ. EX'G. E.J. EXT. F.E. F.E.C.
Finish Finish Floor Floor Floor Drain Fluorescent Foot / Feet Galvanized Gypsum Wall Board Hardware Height Hollow Metal Horizontal Insulation Laminated Lavatory Left Hand Masonry Opening Maximum Mechanical Metal Minimum Mounted Necessary Nominal Not in Contract Not to Scale On Center Opposite Painted Pair Perforated
FIN. FIN. FL. FL. F.D. FLUOR. FT. GALV. G.W.B. HDWR. HT. H.M. HORIZ. INSUL. LAM. LAV. L.H. M.O. MAX. MECH. MTL. MIN. MTD. NEC. NOM. N.I.C. N.T.S. O.C. OPP. PTD. PR. PERF.
P.LAM. PLYWD. QTY. RAD. REQ'D. REINF. R.H. R.D. R.O. SCHED. SECT. SIM. S.F. ST. STL. STL. STRUCT. SUSP. TEL. T.O. T.C.B. T.O.C. TYP. V.I.F. VERT. V.C.T. UTIL. W.C. W/ W/O WD.
PROJECT NOTES 1.
RENOVATION OF A CAFE/BAR IN AN EXISTING ONE-STORY BUILDING PROJECT DATA
ABBREVIATIONS
Plumbing Fixture models are provided to establish a quality of fixture and an operational standard. Equivalent manufacturers are acceptable upon review and approval of Interior Designer.
10. Minimum supply to each fixture shall be 1/2" Ø. All fixtures shall have a shut-off valve at all fixture groups at the risers; provide stops at each fixture.
KITCHEN
Push Side
Note: Y=48" minimum if door has a closer.
Pull Side
FRONT APPROACHES - SWING DOORS
Y 42" min
Push Side
18"
Mirror Lever Valve
Y 42" min
36" MIN. 18"
a. Fixtures to be provided with the required clear floor space.
Y
2. Proposed bathrooms to comply with the applicable requirements of ICC A117.1-2009 for handicapped access, including:
191 SMITH STREET BROOKLYN, NY 11201
54" min
48" min
1. Proposed work to comply with applicable requirements of ICC A117.1-2009.
Y 48" min
HANDICAP ACCESSIBILITY DIAGRAMS AND NOTES - BATHROOMS
All work shall conform with the Contract and with the Project Manual included as part of these Construction Documents. Before commencing work, the Contractor shall file all required Certificates of Insurance with the Department of Buildings, obtain all required permits, and pay all fees required by governing New York City agencies. No work is to begin without proper permits. Examination of the site and portions thereof which will affect this work shall be made immediately by the Contractor, who shall compare existing conditions with the Drawings and satisfy him/herself as to the conditions under which work is to be performed. Contractor shall notify the Designer of any conditions requiring modification before proceeding with the work. Contractor shall at such time ascertain and check locations of existing structure. Contractor's bid shall be based upon this examination.
INTERIORS CONTINUED
T-100
PROJECT INFO & GENERAL NOTES
A-900 PARTITION SCHEDULE
A-050
REMOVALS FLOOR PLANS
A-910
A-100
CELLAR & FIRST FLOOR PLANS
DOOR SCHEDULE, DOOR TYPES, AND TYPICAL DETAILS
A-110
CELLAR & FIRST FLOOR POWER & SIGNAL PLANS
A-920
FINISH SCHEDULE
A-300 A-301
BUILDING SECTIONS BUILDING SECTIONS
A-500 A-501
INTERIOR BATHROOM PLANS INTERIOR ELEVATIONS
A-700 A-701
ENLARGED STAIR PLANS & SECTION ENLARGED STAIR SECTION
A-800 A-801
MILLWORK - SEATING MILLWORK - SEATING
PROJECT:
LEA
SYMBOL LEGEND 12. Contractor shall protect area and new or existing materials and finishes from damage which may occur from construction, demolition, dust, water, etc., and shall provide and maintain temporary barricades, closure walls, etc., as required to protect the public during the period of construction. Damage to new and existing materials, finishes, structures, and equipment shall be repaired or replaced to the satisfaction of the Client at no additional expense to the Client. 13. All work listed, shown, or implied on any Construction Document shall be supplied and installed by the Contractor, except where noted otherwise.
14. Contractor shall notify Designer immediately of all utilities determined in the course of construction as being necessary to be removed which have not otherwise been noted for removal in the Construction Documents. Contractor shall remove such utilities only after consultation with the Designer and Client. Whether predetermined in the Construction Documents 4. Contractor shall verify all dimensions, elevations and or determined in the field, disconnect, cut back to conditions at the site, confirm that the work is buildable as source, and cap all utility services removed. Seal all shown, and notify Designer in writing of any penetrations created by the removal of utilities to match discrepancies prior to proceeding with the work in adjacent construction and finishes. question. 15. All manufactured articles, materials, and equipment 5. All dimensions are to finish face of masonry, centerline of shall be installed, connected, erected, cleaned, and steel, face of finish or casework unless otherwise noted. conditioned per the manufacturer's instructions. In case Dimensions noted as "CLR" are not adjustable without of differences between manufacturer's instructions and Designer's review. Dimensions are not adjustable without the Contract Documents, the Contractor shall notify the Designer's approval unless noted as "+/-". Field Designer before proceeding with the work in question. determine dimensions marked "V.I.F." prior to commencement of construction, and notify any variances 16. All work noted "By Others" or "N.I.C." shall be provided to Designer for resolution. by the Client or under separate contract. Submit to the Designer and Client schedule requirements for this 6. "Align" shall mean to accurately locate finish faces in the "other" work in the construction progress schedule and same plane. coordinate as required to assure orderly sequence of installation. 7. The Contract Documents are complementary. What is shown or referred to on any shall be provided as though 17. The Contractor shall remove all rubbish and waste shown on all. materials of all Subcontractors and trades on a daily basis and shall exercise strict control over job cleaning 8. Do not scale drawings. Dimensions and notes shall to prevent any dirt, debris, or dust from affecting any govern. Drawings at a large scale shall take precedence finished areas in or outside the job site. Burning of over drawings of a small scale. Details shall govern over debris on site shall not be permitted. plans and elevations. 18. Upon completing the job, the Contractor shall leave the 9. Repetitive features not shown on Drawings shall be premises and all affected areas clean and in an orderly completely provided as if drawn in full. manner ready for move-in. This is to include cleaning of all glass (including inside of exterior glass) and frames, 10. Contractor to verify layout of partitions, doors, electrical both new and existing. outlets, data and telephone outlets, light fixtures, and switches with Designer prior to proceeding with 19. Plumbing and electrical work shall be performed by construction. Contractor to verify that no conflicts exist in persons licensed in their trades, who shall arrange for locations of any mechanical, telephone, data, electrical, and obtain inspections and required sign-offs. lighting and plumbing equipment (including all piping, ductwork and conduit) and that all required clearances for 20. The Contractor shall be responsible for the protection installation and maintenance are provided. of all conditions and materials within the proposed construction area. The Contractor shall design and 11. Visits to the site by the Designer are only intended to install adequate shoring and bracing for all structural or ensure compliance with the design intent and should not removal tasks. The Contractor shall have sole be construed as being related to site safety. responsibility for any damage or injuries caused by or during the execution of the work.
DOOR NUMBER
100
ROOM NAME
ROOM INFO
CONF. RM. 100
ROOM NUMBER
WINDOW NUMBER
1
WALL TYPE BUILDING ELEVATION
BUILDING SECTION
1
ELEVATION NUMBER
A-200
SHEET NUMBER
SECTION NUMBER
1 A-300
SHEET NOTE TAG ALIGN FINISHES
1
B
A-500
ELEVATION NUMBER SHEET NUMBER
RATED PARTITION
A
2
NEW GYP. BD. WALLS DRAWING:
SHEET NUMBER
A
INTERIOR ELEVATION D
REVISION
191 SMITH STREET BROOKLYN, NEW YORK 11201
EXISTING WALLS TO REMAIN
LEVEL CHANGE
1
NOT IN PROJECT SCOPE
PROJECT INFORMATION AND GENERAL NOTES
ALIGN
8"
EXISTING SWING DOOR TO REMAIN ISSUE DATE :
C
DETAIL TAG
1
DETAIL NUMBER
A-800
SHEET NUMBER
Z
COLUMN LINE
+ 8'-0"
CENTERLINE
CL
DRAWN BY :
CELINE LUI
NORTH ARROW PROJECT NUMBER :
COLUMN NUMBER
NEW SWING DOOR
INTERMEDIATE LANDING
ELEVATION HEIGHT
03.12.2020
NEW SLIDING DOOR
DRAWING :
2000 SEAL :
VICINITY MAP
NO SCALE
DOB JOB NUMBER :
DOCUMENT :
01
SITE DRAWING NUMBER:
T-100.00 S SCAN STICKER:
GENERAL NOTES
A
B
NO ATTEMPT IS MADE TO MENTION EVERY ITEM OF REMOVAL OR ALTERNATION WORK REQUIRED. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK NECESSARY TO COMPLETE THE PROJECT IN FULL COMPLIANCE WITH THE INTENDED RESULTS AND DESIGN INTENT DESCRIBED BY THE DRAWINGS.
C
90'-541" 55'-441"
1.
ALL SURFACES DESIGNATED TO REMAIN SHALL BE PROTECTED TO ASSURE THAT THEY ARE NOT DAMAGED IN REMOVALS PROCESS. ANY ITEMS THAT ARE DAMAGED SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE CLIENT. AVOID UNNECESSARY CUTTING AND PATCHING.
2.
DIMENSION INFORMATION IS SHOWN TO FACILITATE THE RENOVATION OF THESE SPACES. ALL REMOVALS WORK MUST BE COORDINATED WITH THE ARCHITECTURAL DRAWINGS. COORDINATE AND VERIFY SCOPE OF ELECTRICAL REMOVALS WITH THE DESIGNER AND ENGINEER PRIOR TO COMMENCEMENT WITH WORK
3.
IF THE GENERAL CONTRACTOR DISCOVERS DISCREPANCIES, OMISSIONS, OR HIDDEN CONDITIONS DIFFERING FROM REMOVALS INFORMATION, GENERAL CONTRACTOR NOTIFY THE INTERIOR DESIGNER BEFORE PROCEEDING WITH WORK.
4.
PRIOR TO COMMENCEMENT OF REMOVALS, GENERAL CONTRACTOR TO SCHEDULE ON-SITE MEETING WITH THE INTERIOR DESIGNER AND BUILDING MANAGEMENT TO REVIEW EXTENT OF REMOVALS WORK.
5.
PROVIDE TEMPORARY DUST CONTROL BARRIERS BETWEEN AREAS OF WORK AND OCCUPIED AREAS. CAP VENTS AND TAKE MEASUREMENTS FOR DUST CONTROL.
6.
ALL WORK TO BE DONE IN ACCORDANCE WITH OSHA STANDARDS
35'-1"
1
9'-334"
10'-434"
10
3'-4"
3 12
2
12'-103 8"
7'-034"
5 25'-0"
9
3" 20'-28
7
4
5
4
5
7
TYP.
6
6
3
11
TYP.
4
TYP.
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
3
8'-721"
7 4
5
5
TYP.
1 4
10 SHEET NOTES
4
4
1 A-050
FIRST FLOOR REMOVALS PLAN
3/16" = 1'-0"
A
B
1
REMOVE EXISTING STAIR AND HANDRILS
2
REMOVE PORTION OF EXISTING FLOOR AND FLOOR FRAMING. SHORE AS REQUIRED.
3
REMOVE EXISTING EXTERIOR WALL; SHORE AS REQUIRED
4
REMOVE EXISTING INTERIOR NON-LOADBEARING PARTITION
5
REMOVE EXISTING DOOR AND FRAME
6
REMOVE EXISTING PLUMBING FIXTURES AND FINISHES
7
REMOVE EXISTING FINISH FLOORING AND SUB-FLOORING BELOW
8
REMOVE PORTION OF EXISTING COLUMNS
9
FACE OF EXISTING CELLAR WALL BELOW
10
EXCAVATE FOR FUTURE WATERPROOFING AND TRENCH DRAIN ALONG EXISTING FOUNDATION WALL
11
REMOVE EXISTING PAVERS AND SETTING MATERIAL
12
EXISTING DOOR TO REMAIN; SCOPES OF WORK TO BE DETERMINED
C
PROJECT:
LEA 191 SMITH STREET BROOKLYN, NEW YORK 11201 BLOCK: 397
90'-541" 55'-441"
BIN:3336059
CELLAR AND FIRST FLOOR REMOVALS FLOOR PLANS
35'-1"
ISSUE DATE :
1
03.12.2020
14
9'-334"
LOT: 07
DRAWING:
PROJECT NUMBER :
DRAWN BY :
CELINE LUI DRAWING :
2000
8
8
8
SEAL :
25'-0"
7'-034"
2
5
5
8
8
5
8 4
4
CRAWLSPACE (N.I.C.)
5
CONSTRUCTION LEGEND NOT IN PROJECT SCOPE
3
8'-721"
EXISTING PARTITION TO REMAIN
4
4
4
4
4
4
4
EXISTING SWING DOOR TO REMAIN
1 4
DOB JOB NUMBER :
4
01
NEW GYPSUM BOARD PARTITION
DRAWING NUMBER:
A-050.00
NEW SLIDING DOOR
NEW SWING DOOR S SCAN STICKER:
2 A-050
CELLAR REMOVALS PLAN
DOCUMENT :
RATED SEPARATION
FIRE ALARM PULL STATION FIRE ALARM HORN/STROBE
3/16" = 1'-0"
EXIT SIGN
F.A.
OCCUPANCY NOTES
A
1 A-300
B
C
CELLAR AREA: DOMINANT OCCUPANCY: OCCUPANT LOAD FACTOR: SECONDARY OCCUPANCY: OCCUPANT LOAD FACTOR: TOTAL OCCUPANTS:
D 1 A-800
100'-0"
24'-341"
31'-1"
SEATING 1
9'-634"
35'-1"
BAR
105
102
FIRST FLOOR AREA: DOMINANT OCCUPANCY: OCCUPANT LOAD FACTOR: TOTAL OCCUPANTS:
1,215G.S.F ASSEMBLY(A-2 KITCHEN) 100 NET ASSEMBLY(A-2 CAFE) 15 NET (UNCONCENTRATED) 30 1,215G.S.F ASSEMBLY(A-2 CAFE) 15 NET (UNCONCENTRATED) 30
SEATING 2 106
1 GENERAL NOTES 1 A-700
9'-134"
F
D
11 16
F
8
D
1
1. ALL GYPSUM BOARD PARTITIONS SHALL BE COVERED BY LATEX PRIMER AND THREE COATS OF ACRYLIC LATEX PAINT(SEMI-GLOSS); TYPICAL UNLESS OTHERWISE NOTED
6
2. ROUTING OF ALL EXPOSED CONDUIT, JUNCTION BOXES, ETC., IS TO BE COORDINATED TO ENSURE CLEAN INSTALLATION. THIS INCLUDES METHODS OF ATTACHMENT
12
2 1 A-301
6'-534"
25'-0"
100
ENTRY
100
TO GO
101
11
DN
F
3 109
3
9'-421"
15
15 11
E
F F
11
E
E
B
E
B
103
F
104
15 11
SEATING 5 109
E D
E
4 SEATING 3 107
SEATING 4 108
STAIR
WC (ADA)
S1 1 A-500
1 A-100
DESIGN
SHEET NOTES
14
13
CELINE CAROL LUI
FIRST FLOOR PLAN
WC (ADA)
7
103
NEW STAIR WITH CONTINUOUS STEEL HANDRIL AND GUARDRAIL
2
NEW BUILT-IN MILLWORK AT GARDEN
3
NEW COUNTERTOP
4
EQUIPMENT AND FIXTURES AT PREP AREA TO BE CONFIRMED BY KITCHEN CONSULTANT
5
NEW GREEN WALL PARTITION
6
NEW BUILT-IN MILLWORK
7
NEW BUILT-IN BANQUETTE
8
NEW BUILT-IN TABLE
9
NEW FINISH FLOOR OVER NEW SUB-FLOOR SHEATHING
10
104
3/16" = 1'-0"
36 BOND ST, BROOKLYN, NY 11230
1
CCL@GMAIL.COM 408 578 9091
NEW BUILT-IN BAR COUNTERTOP
11
NEW TILE FLOORING
12
EXISTING DOOR; SCOPE OF WORK TO BE DETERMINED
13
REPLACE DOOR WITH NEW WINDOW
14
NEW BUILT-IN STONE AT RECEPTION
15
NEW PLUMBING FIXTURES
PROJECT:
LEA
A
1 A-300
B
2 A-700
2 A-500
C
191 SMITH STREET BROOKLYN, NEW YORK 11201
D
DRAWING:
90'-541" 24'-341"
31'-1"
SEATING 2 C02
CELLAR AND FIRST FLOOR CONSTRUCTION PLANS
35'-1"
CLOSET
SEATING 3 C03
C03 ISSUE DATE :
1
03.12.2020 C
9'-134"
UP
F
E F
C01
E
C
15
B
7
PROJECT NUMBER :
11
6'-534"
25'-0"
4
C02
1 A-700
F
E
SEAL :
11
1
3
CRAWLSPACE (N.I.C.)
EXISTING PARTITION TO REMAIN
11
UP B
CONSTRUCTION LEGEND NOT IN PROJECT SCOPE
F
C04
2
DRAWING :
2000
2 C
CELINE LUI
C03
UP
1 A-301
DRAWN BY :
E
9'-421"
6 C
F
EXISTING SWING DOOR TO REMAIN
E
F F
15
DOB JOB NUMBER :
E
4
01
NEW GYPSUM BOARD PARTITION
KITCHEN
C01
SEATING 4 C04
WC
DRAWING NUMBER:
A-100.00
NEW SLIDING DOOR
C04
NEW SWING DOOR S SCAN STICKER:
2 A-100
CELLAR FLOOR PLAN
DOCUMENT :
RATED SEPARATION
FIRE ALARM PULL STATION FIRE ALARM HORN/STROBE
3/16" = 1'-0"
EXIT SIGN
F.A.
GENERAL NOTES
A
B
C
D
1.
ROUTING OF ALL EXPOSED CONDUIT, JUNCTION BOXES,ETC. IS TO BE COORDINATED TO ENSURE CLEAN INSTALLATION, THIS INCLUDES METHODS OF ATTACHMENT.
90'-541" 24'-341"
31'-1"
SEATING 1
35'-1"
105
BAR
102
SEATING 2 106
9'-134"
1
CELINE CAROL LUI
2
DESIGN
6'-534"
25'-0"
SHEET NOTES ENTRY
100
TO GO
101
1
DN
36 BOND ST, BROOKLYN, NY 11230
POWER AND SIGNAL REQUIREMENTS FOR PREP AREA TO BE CONFIRMED BY KITCHEN CONSULTANT.
CCL@GMAIL.COM 408 578 9091
9'-421"
3
4 SEATING 3 107
1 A-110
SEATING 4 108
STAIR
S1
FIRST FLOOR POWER AND SIGNAL PLAN
WC (ADA)
103
WC (ADA)
104
3/16" = 1'-0"
PROJECT:
LEA
A
B
C
191 SMITH STREET BROOKLYN, NEW YORK 11201
D
DRAWING:
90'-541" 24'-341"
31'-1"
SEATING 2 C02
CELLAR AND FIRST FLOOR POWER AND SIGNAL PLANS
35'-1"
SEATING 3 C03
CLOSET
C05 ISSUE DATE :
1
9'-134"
03.12.2020 UP
PROJECT NUMBER :
CELINE LUI DRAWING :
2000 UP
6'-534"
2
25'-0"
DRAWN BY :
SEAL :
CRAWLSPACE (N.I.C.)
1
ELECTRICAL SYMBOL LEGEND WAP
WIRELESS ACCESS POINT (WAP) COMPUTER DATA OUTLET
3
TELEPHONE JACK
UP
COMPUTER DATA OUTLET AT THE FINISH FLOOR TELEPHONE JACK AT THE FINISH FLOOR
9'-421"
TV
SATELLITE TELEVISION OUTLET DIGITAL CABLE OUTLET
T
DOB JOB NUMBER :
DOCUMENT :
WALL MOUNTED DUPLEX RECEPTACLE OUTLET THERMOSTAT
01
WALL MOUNTED QUADRUPLEX RECEPTACLE OUTLET
4
DRAWING NUMBER:
RECESSED DUPLEX OUTLET AT THE FINISH FLOOR
KITCHEN
C01
SEATING 4 C04
WC
C06
RECESSED DOUBLE DUPLEX OUTLET AT THE FINISH FLOOR RECESSED DUPLEX OUTLET AT THE CEILING
GFI K.P.
2 A-110
CELLAR POWER AND SIGNAL PLAN
3/16" = 1'-0"
A-110.00
GROUND FAULT INTERRUPTION SECURITY ALARM KEYPAD
S SCAN STICKER:
GENERAL NOTES
1
2
3
1.
ALL GYPSUM BD. PARTITIONS SHALL BE COVERED BY LATEX PRIMER AND THREE (3) COATS OF ACRYLIC LATEX PAINT (SEMI-GLOSS); TYPICAL UNLESS OTHERWISE NOTED
2.
ROUTING OF ALL EXPOSED CONDUIT, JUNCTION BOXES, ETC., IS TO BE COORDINATED TO ENSURE CLEAN INSTALLATION. THIS INCLUDES MEATHODS OF ATTACHMENT
4
1 A-701
2 A-800
ENTRY
100
TO GO
101
BAR
102
SEATING 1 105
SHEET NOTES
1
ROOF
+ 15'-3 1/4"
NEW STAIR WITH CONTINUOUS STEEL HANDRIL AND GUARDRAIL
2
NEW GREEN GARDEN MILLWORK
3
NEW SLIDING ALUMINUM AND GLASS DOORS AND INSECT SCREENS
4
EQUIPMENTS AND FIXTURES AT PREP AREA TO BE CONFIRMED BY KITCHEN CONSULTANT
5
NEW GREEN WALL PARTITION
CELINE CAROL LUI
6
NEW BUILT-IN MILLWORK
DESIGN
7
NEW BUILT-IN BANQUETTE
8
NEW BUILT-IN TABLE
9
NEW FINISH FLOOR OVER NEW SUB-FLOOR SHEATHING
15'-341"
Beer
leoville
HENKE
干红葡
萄酒
8
15
14
10
5
3 13
36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
1
1ST FLR. FIN. FLR.
10'-821"
+ 0'-0"
7
4
2
CELLAR
-10'-8 1/2"
1 A-300
BUILDING SECTION (LOOKING NORTH)
3/16" = 1'-0"
PROJECT:
LEA
1
2
3
191 SMITH STREET BROOKLYN, NEW YORK 11201
4
DRAWING:
2 A-701
BUILDING SECTIONS
ISSUE DATE :
DRAWN BY :
CELINE LUI
ROOF
+ 15'-3 1/4" PROJECT NUMBER :
15'-341"
3
DRAWING :
SEAL :
Beer
leoville
HENKE
6 102
BAR
WC (ADA)
103
1ST FLR. FIN. FLR.
10'-821"
+ 0'-0"
DOB JOB NUMBER :
1 C03
CLOSET
WC
DOCUMENT :
C04 DRAWING NUMBER:
A-300.00
CELLAR
-10'-8 1/2"
S SCAN STICKER:
2 A-300
BUILDING SECTION (LOOKING EAST)
3/16" = 1'-0"
C
5'-734"
8'-0"
CELINE CAROL LUI
8'-0"
DESIGN
3" 18
2'-11"
36 BOND ST, BROOKLYN, NY 11230
3
CCL@GMAIL.COM
1'-6"
408 578 9091 H.3
B
A
CL
P.3
P.3
H.1
G
5'-0" DIA. CLR
5'-0" DIA. CLR
J.2
8'-0"
CLR
8'-0" CLR
J
H.2
C
1 A-501
B
1'-6"
C
WC (ADA)
30" X 48" CLR
P.1 P.2
D
A E
F
D
2 A-501
B
P.1 P.2
CL
A
C
103
WC (ADA)
104
PROJECT:
LEA 1 A-500
ENLARGED FLOOR PLAN - GENDER NEUTRAL ACCESSIBLE BATHROOMS
1/2" = 1'-0"
191 SMITH STREET BROOKLYN, NEW YORK 11201
DRAWING:
ENLARGED FLOOR PLANS BATHROOMS AND JAN. CLOSET P.4 P.5 ISSUE DATE :
A D
3 A-501
03.12.2020
DRAWN BY :
CELINE LUI
B PROJECT NUMBER :
C
DRAWING :
2000 SEAL :
CLOSET
2 A-500
C03
ENLARGED FLOOR PLAN - JANITORS CLOSET
DOB JOB NUMBER :
DOCUMENT :
1/2" = 1'-0"
01 DRAWING NUMBER:
A-500.00 S SCAN STICKER:
C
GYP. BD. WALL. PTD. (TYP.)
E
H3
C
C
CELINE CAROL LUI
H3
H3
F
WALL MTD. HAND DRYER
G
D
DESIGN
G
WALL MTD. TOILET SEAT COVER DISPENSER
H1 H2
36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM
H2
408 578 9091
WALL MTD. LAVATORY CERAMIC TILE WALL BASE
B
H1
A
A NORTH
1 A-501
B EAST
C SOUTH
GENDER NUETRAL ACCESSIBLE BATHROOMS 103 - INTERIOR ELEVATIONS CL
6"
D WEST
1/2" = 1'-0"
CL
CL
3'-0" GRAB BAR
PROJECT:
LEA
4"
3'-434"
INTERIOR ELEVATIONS
2'-5"
2'-915 16"
DRAWING:
1'-45 8"
1'-10"
3" 3'-716
3'-3"
5'-4"
6'-1115 16"
15" 6'-1116
191 SMITH STREET BROOKLYN, NEW YORK 11201
A NORTH
B EAST
C SOUTH
D WEST
ISSUE DATE :
03.12.2020
2 A-501
GENDER NUETRAL ACCESSIBLE BATHROOM 104 - INTERIOR ELEVATIONS
PROJECT NUMBER :
1/2" = 1'-0"
DRAWN BY :
CELINE LUI DRAWING :
2000 SEAL :
WOOD DOOR AND STL. FRAME. PTD.
GYP. BD. WALL. PTD. (TYP.)
WALL MOUNTED FAUCET
DOB JOB NUMBER :
01
4'-013 16"
DRAWING NUMBER:
3'-0"
CERAMIC TILE WALL BASE
A-501.00
FLR. MTD. MOP SINK
A NORTH
B EAST
C SOUTH
D WEST S SCAN STICKER:
3 A-501
JANITOR'S CLOSET- INTERIOR ELEVATIONS
DOCUMENT :
1/2" = 1'-0"
2 A-701
B
9'-078"
DIM. (LOWER STAIR RUN)
3'-0"
1'-11"
7 EQ. TREADS
LANDING
2'-915 16"
3'-8"
1'-0"
121"
121"
2
CELINE CAROL LUI STAIR
DESIGN
S1 4'-3"
36 BOND ST, BROOKLYN, NY 11230
DN
1 A-701
CCL@GMAIL.COM 408 578 9091
TO GO
3'-8"
3 101
DIM. (UPPER STAIR RUN)
3'-11" LANDING
1 A-700
8 EQ. TREADS
ENLARGED STAIR PLAN - FIRST FLOOR
1/2" = 1'-0"
B
2 A-701
9'-078"
PROJECT:
LEA
DIM. (LOWER STAIR RUN)
3'-0"
1'-11"
191 SMITH STREET BROOKLYN, NEW YORK 11201
7 EQ. TREADS
LANDING 1'-0"
UP
S1 2'-915 16"
DRAWING:
3'-8"
STAIR
ENLARGED STAIR PLANS
2 ISSUE DATE :
DRAWN BY :
CELINE LUI DRAWING :
4'-3"
PROJECT NUMBER :
1 A-701
SEAL :
UP
3'-8"
3
DOB JOB NUMBER :
SEATING 3 C03
DOCUMENT :
DRAWING NUMBER:
A-700.00 2 A-700
ENLARGED STAIR PLAN - CELLAR
S SCAN STICKER:
1/2" = 1'-0"
2 A-300
B
C
2
1 A-300
3
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
SECOND FLOOR
SECOND FLOOR
14'-241"
+ 14'-2"
14'-241"
+ 14'-2"
PROJECT:
191 SMITH STREET BROOKLYN, NEW YORK 11201
3'-6"
7" 3'-216
7'-0"
LEA
DRAWING:
FIRST FLOOR
FIRST FLOOR
+ 0'-0"
ENLARGED STAIR SECTIONS
+ 0'-0"
03.12.2020
5'-1015 16"
5'-1015 16"
ISSUE DATE :
CELINE LUI DRAWING :
2000
7 3'-216 "
7 3'-216 "
3'-615 16"
1" 3'-116
9" 3'-416
PROJECT NUMBER :
DRAWN BY :
SEAL :
FIRST LANDING
FIRST LANDING
3'-0"
9" 4'-916
- 5'-11"
9" 4'-916
- 5'-11"
DOB JOB NUMBER :
CELLAR
DOCUMENT :
CELLAR
- 10'-8"
01
- 10'-8" DRAWING NUMBER:
A-701.00 1 A-701
ENLARGED STAIR SECTION
2 1/2" = 1'-0"
A-702
ENLARGED STAIR SECTION
S SCAN STICKER:
1/2"
1
2
1 A-801
C 7" 18'-1116 7" 4'-716
FIXED SHELF
OAK SHELVING
STONE COUNTERTOP
9" 1'-616
2'-041"
1" 1'-516
ELEVATED STONE SERVICE DESK
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM
OAK BAR SHELVING
408 578 9091
1'-415 16"
8'-881"
2"
4 A-800
1'-421"
2"
3 A-800
2"
Beer
HENKE
1'-421"
WOODEN BAR COUNTER
leoville
11'
2"
STONE COUNTERTOP
9" 1'-716
2
5" 78
1 A-800
1
ENLARGED BAR PLAN
3/4" = 1'-0" 881"
A-800
3'-881"
WOODEN BAR COUNTER
C
3 A-800
BAR ELEVATION (LOOKING WEST)
3/4" = 1'-0"
PROJECT:
LEA 191 SMITH STREET BROOKLYN, NEW YORK 11201
DRAWING:
MILLWORK- BAR
ISSUE DATE :
1'-415 16"
2"
03.12.2020 PROJECT NUMBER :
2"
Beer
leoville
DRAWN BY :
CELINE LUI DRAWING :
Beer
leoville
HENKE
HENKE
2000
1'-421"
FIXED SHELF
1'-421"
2"
SEAL :
葡萄
STONE COUNTERTOP
干红
葡萄
酒
酒
9" 1'-716
11'
2"
干红
5" 78
3 A-801
DOB JOB NUMBER :
3'-881"
RANGE
DOCUMENT :
01
881"
DRAWING NUMBER:
A-800.00 S SCAN STICKER:
2 A-800
BAR ELEVATION (LOOKING NORTH)
4 3/4" = 1'-0"
A-800
BAR ELEVATION (LOOKING NORTH)
3/4" = 1'-0"
LED STRIP LIGHT RECESSED INTO 15 DEGREE ANGLED GROOVE ALONG REAR OF SHELF TO FULL LENGTH OAK SHELF WITH STAINED FINISH CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
2 A-801
INVISIBLE BRACKET AND CONCEALED FASTENERS
RECESSED DOWNLIGHT (TYP.)
FIXED SHELF (TYP.) 2 A-801
SHELF DETAIL
ELEVATED SERVICE DESK BEYOND
3"=1'-0"
STONE COUNTERTOP PROJECT:
LEA 191 SMITH STREET BROOKLYN, NEW YORK 11201
STONE COUNTERTOP WOODBLOCKING
DRAWING:
STEEL PLATE
3"
PLYWOOD
4"
2"
BRACKET
HOOK
ISSUE DATE :
03.12.2020 1 2"
THREADED ROD AND NUTS SECURED ON BOTH ENDS
3" 1'-916 8"
3'
4'
STONE FACING
4"
MILLWORK BAR DETAILS
PROJECT NUMBER :
DRAWN BY :
CELINE LUI DRAWING :
2000 SEAL :
ADJUSTABLE SHELVING UNITS STONE COUNTERTOP
FOOT REST
DOB JOB NUMBER :
BOTTOM RACK
DOCUMENT :
01 DRAWING NUMBER:
1 A-801
BAR SECTION
1/2" = 1'-0"
3 A-801
COUNTER DETAIL
A-801.00 3"=1'-0"
S SCAN STICKER:
PARTITION TYPES
PARTITION NOTES
UNDERSIDE OF STRUCTURE
UNDERSIDE OF STRUCTURE
FIRE-RATED SEALANT
FIRE-RATED SEALANT
SLOTTED TOP TRACK (TYP.)
SLOTTED TOP TRACK (TYP.)
SLOTTED TOP TRACK (TYP.)
FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
FINISHES CEILING REFER TO R.C.P.
CLG.
UNDERSIDE OF STRUCTURE
FINISHES CEILING REFER TO R.C.P.
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
FINISHES CEILING REFER TO R.C.P.
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
CLG.
GENERAL PARTITION NOTES: 1. Partition assemblies and associated fire resistance ratings are taken from RS-5-1B of the Gypsum Associations' "Fire Resistance Design Manual, 15th Edition." They were adopted under NYC Building Code Revision 262-86, dated 04/22/86.
CLG.
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
2. Drywall and masonry construction shall include continuous firestopping at all duct, fire-rated partitions.
pipe and conduit penetrations through
3. Seal the entire perimeter of fire-rated partitions airtight with fire rated sealant. 4. All fire-resistive partitions shall be constructed in compliance with testing requirements and manufacturer's recommendations for conditions as required. Construction of all systems will be equal to that tested assembly. 5. All non-load bearing material stud partitions are to extend to underside of structure, typical unless otherwise noted. 6. Provide moisture-resistant gypsum board of damp areas. 7. Provide Durock Cement Board at wet areas. 8. Tap and bed any corners and joints ready for finish.
INSULATION AS SCHEDULED
INSULATION AS SCHEDULED
INSULATION AS SCHEDULED
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
TWO(2) LAYERS 58" TYPE X GYP. BD. BOTH SIDES
5 8"
5 8"
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
PLAN
PLAN
TYPE X GYP. BD. BOTH SIDES
PLAN
MAXIMUM STUD SPACING = 16" ON CENTER ALLOWABLE DEFLECTION = L / 240
BASE AS SCHEDULED
BASE AS SCHEDULED
BASE AS SCHEDULED
CONTINUOUS METAL RUNNER
CONTINUOUS METAL RUNNER
CONTINUOUS METAL RUNNER
FIRE-RATED SEALANT
FIRE-RATED SEALANT
ACOUSTICAL SEALANT
TOP OF STRUCTURE
TOP OF STRUCTURE
TOP OF STRUCTURE
FASTENER
FASTENER
BASE
C
TYPE X GYP. BD. BOTH SIDES
FASTENER
BASE
2-HR RATED PARTITION
3" = 1'-0"
B
BASE
NON-LOADBEARING PARTITION 3" = 1'-0" 1-HR WHERE INDICATED
A
NON-LOAD-BEARING PARTITION
3" = 1'-0" PROJECT:
LEA
UNDERSIDE OF STRUCTURE
UNDERSIDE OF STRUCTURE
UNDERSIDE OF STRUCTURE
ACOUSTIC SEALANT
ACOUSTIC SEALANT
FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
SLOTTED TOP TRACK (TYP.)
FINISHES CEILING REFER TO R.C.P.
FINISHES CEILING REFER TO R.C.P. 1"
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
CLG.
CLG.
INSULATION AS SCHEDULED
INSULATION AS SCHEDULED
STONE AS SCHEDULED
STONE AS SCHEDULED
5 8"
5 8"
TYPE X GYP. BD. BOTH SIDES
DRAWING:
PARTITION SCHEDULE
FINISHES CEILING REFER TO R.C.P.
PROVIDE MIN 1" OVERLAP AT TRANSITION TO 58" MOISTURE RESISTANT GYP. BD.
PLASTER SPOTS AS REQUIRED
CLG.
ACOUSTICAL SEALANT
SLOTTED TOP TRACK (TYP.) FINISHED CEILING-REFER TO REFLECTED CEILING PLANS
SLOTTED TOP TRACK (TYP.)
191 SMITH STREET BROOKLYN, NEW YORK 11201
TAPE AND COMPOUND EXPOSED JOINTS AT GYPSUM BOARD CEILING OR SOFFIT (TYP.)
ISSUE DATE :
03.12.2020 PROJECT NUMBER :
INSULATION AS SCHEDULED
TYPE X GYP. BD. BOTH SIDES
5 8"
DRAWN BY :
CELINE LUI DRAWING :
2000
TYPE X GYPSUM BOARD SEAL :
PLASTER SPOTS AS REQUIRED
PLAN
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
WALL FINISH AS SCHEDULED
WALL FINISH AS SCHEDULED
PLAN
ROOM SIDE
METAL STUD @ 16 O.C. MAX. (20 GAUGE MIN.)
ADDITIONAL LAYERS OF GYP. BD AS SCHEDULED
PLAN
ROOM SIDE
FACE OF EXISTING WALL OR STRUCTURE BASE AS SCHEDULED DOB JOB NUMBER :
CONTINUOUS METAL RUNNER
CONTINUOUS METAL RUNNER
PLASTER SPOTS AS REQUIRED
PLASTER SPOTS AS REQUIRED TOP OF STRUCTURE
FASTENER
TOP OF STRUCTURE
FASTENER
BASE
A-900.00
FASTENER
BASE
01 DRAWING NUMBER:
ACOUSTICAL SEALANT TOP OF STRUCTURE
BASE S SCAN STICKER:
F
WET WALL PARTITION (STONE)
3" = 1'-0"
E
WET WALL PARTITION (TILE)
3" = 1'-0"
DOCUMENT :
CONTINUOUS METAL RUNNER
D
FURRED PARTITION
3" = 1'-0"
DOOR TYPES
DOOR SCHEDULE
FLOOR
DOOR NO.
CELLAR
CL
DOOR LEAF & WINDOW
EQ
FRAME ROOM NAME
TYPE
C01
KITCHEN/ C01
V.I.F.
C02
KITCHEN/ C01
B
C03
CLOSET/ C03
A
C04
WC/ C04
A
MATERIAL
HARDWARE REMARKS
THICK. SIZE (W X H)
OPERATION
RATING
MATERIAL TYPE
SET
V.I.F.
V.I.F.
V.I.F.
SWING
-
V.I.F.
-
-
EXISTING DOOR
STL / TGL
1-3/4"
3'-0" x 7'-0"
SWING
-
STL
DR
-
-
STL
1-3/4"
3'-0" x 7'-0"
SWING
-
STL
DR
-
-
STL
1-3/4"
3'-0" x 7'-0"
SWING
-
STL
DR
-
-
EQ
WINDOW
CELINE CAROL LUI DESIGN
CL
36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM
LEVER
408 578 9091
3'-2" TYP.
5'-0" TYP.
CL
DOOR LEVER (TYP.)
TYPE A
TYPE B
FIRST FLOOR
100
ENTRY/ 100
V.I.F.
V.I.F.
V.I.F.
SWING
-
V.I.F.
-
-
EXISTING ENTRY DOOR (PAIR)
103
WC (ADA)/ 103
A
STL
1-3/4"
3'-0" x 7'-0"
SWING
-
STL
DR
-
-
104
WC (ADA)/ 104
A
STL
1-3/4"
3'-0" x 7'-0"
SWING
-
STL
DR
-
-
109
SEATING 5/109
C
ALUM/ TGL
1-3/8"
(2)3'-0" x 7'-0"
SWING
-
ALUM
DR
-
EXTERIOR GLASS DOOR (PAIR)
V.I.F.
PROJECT:
LEA
CL
LEVER
191 SMITH STREET BROOKLYN, NEW YORK 11201
3'-2"
DRAWING:
DOOR SCHEDULE, DOOR TYPES, AND TYPICAL DETAILS
ISSUE DATE :
TYPE C
03.12.2020 PROJECT NUMBER :
DRAWN BY :
CELINE LUI DRAWING :
2000 SEAL :
HOLLOW METAL DOOR; REFERENCE DOOR SCHEDULE FOR TYPE AND RATING 1 TYP. 516"
PROVIDE CONTINUOUS PLASTER GROUT AT HOLLOW METAL DOOR FRAME (TYP.).
JAMB ANCHOR AS REQ.
GENERAL DOOR NOTES
NUMBER OF HINGES PER DOOR
1. Reference A-100 series Floor Plans for door tags.
Provide 3 hinges for all doors up to 7'-6" in height.
63 TYP. 8"
63 8" TYP.
1'-8 5 16" TYP.
CONTINUOUS CHANNEL HEADER AS REQUIRED
REFERENCE PARTITION SCHED.
1'-8 5 TYP. 16"
PROVIDE CONTINUOUS PLASTER GROUT AT HOLLOW METAL DOOR FRAME (TYP.). CONTINUOUS DOUBLE STUDS AT JAMB (TYP.)
1 TYP. 516"
F.O. WALL BASE BELOW WHERE SCHEDULED
PROVIDE UNDERCUT AT DOOR SILL AS SCHEDULED (TYP.)
GYPSUM BOARD PARTITION: REFERENCE A-100 SERIES PLANS FOR TYPES AND A-400 FOR PARTITION SCHEDULE FOR ASSEMBLIES
UNDERCUT (TYP.). AS SCHEDULED
F.O. FLOOR FINISH
2 A-910
HEAD & SILL DETAILS H.M. DOOR (TYP.)
1 3" = 1'-0"
A-910
JAMB DETAIL H.M. DOOR (TYP.)
3" = 1'-0"
Provide 4 hinges for doors greater than 7'-6" in height.
DOB JOB NUMBER :
DOCUMENT :
01
Provide 5 hinges for doors greater than 10'-0" in height. DRAWING NUMBER:
ABBREVIATIONS
AL DR HM SCW SR STL S.STL TGL TYP. U.O.N.
Aluminum Double Rabbet Hollow Metal Solid Core Wood Single Rabbet Steel Stainless Steel Tempered Glazing Typical Unless Otherwise Noted
A-901.00 S SCAN STICKER:
FINISH SCHEDULE
REMARKS
EXISTING TO REMAIN
STONE
B.O. EX'G STRUCTURE
SUSP. ACOUSTIC PLANKS
SUSP. GYPSUM BOARD
EXISTING TO REMAIN
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
ACOUSTIC PLANKS
STONE
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
WEST
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
ACOUSTIC PLANKS
STONE
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
ACOUSTIC PLANKS
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
STONE
CERAMIC TILE
GYPSUM BOARD
NO WALL BASE
EXISTING TO REMAIN
ACOUSTIC PLANK
CERAMIC TILE, COVERED
VINYL, STRAIGHT
VINYL, COVERED
EXISTING TO REMAIN
PRECAST CONC. PAVERS
STEEL & ALUMINUM COUNTERTOP
STONE COUNTERTOP
CONCRETE FLOORING
ENGINEERED WOOD PLANKS
SOUTH
C01
KITCHEN
PATCH, SKIM COAT, AND PAINT EXISTING GYPSUM BOARD SHEATHING AT CEILING OF KITCHEN AREA
SEATING 2
-
C03
SEATING 3
-
C04
SEATING 4
-
C05
CLOSET
-
C06
WC
PATCH, SKIM COAT, AND PAINT GYPSUM BOARD SHEATHING OF WC AREA
WALLS
CEILING
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
REMARKS
EXISTING TO REMAIN
B.O. EX'G STRUCTURE
STONE
SUSP. ACOUSTIC PLANKS
SUSP. GYPSUM BOARD
EXISTING TO REMAIN
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
ACOUSTIC PLANKS
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
WEST
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
ACOUSTIC PLANKS
STONE
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
SOUTH
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
CERAMIC TILE
GYPSUM BOARD
EXISTING TO REMAIN
EAST
ALUMINUM & GLASS DOORS ENGINEERED WOOD PLANKS
ACOUSTIC PLANKS
CERAMIC TILE
GYPSUM BOARD
NO WALL BASE
EXISTING TO REMAIN
ACOUSTIC PLANK
CERAMIC TILE, COVERED
VINYL, STRAIGHT
VINYL, COVERED
EXISTING TO REMAIN
PRECAST CONC. PAVERS
STEEL & ALUMINUM COUNTERTOP
CERAMIC MOSAIC DIAMOND TILES
STONE
NORTH
STONE
BASE
ACOUSTIC PLANKS
FLOOR ROOM NAME
STONE
ROOM NO.
FIRST FLOOR
CEILING
EAST
C02
STONE COUNTERTOP
FLOOR
WALLS NORTH
CONCRETE FLOORING
CELLAR
BASE
ACOUSTIC PLANKS
FLOOR ROOM NAME
CERAMIC MOSAIC DIAMOND TILES
NO.
STONE
ROOM
ENGINEERED WOOD PLANKS
FLOOR
PROJECT:
100
ENTRY
-
101
TO GO
-
102
BAR
REFERENCE MILLWORK DRAWINGS FOR ADDITION INFORMATION AND DETAILS
103
WC (ADA)
-
104
WC (ADA)
-
105
SEATING 1
-
106
SEATING 2
-
107
SEATING 3
-
108
SEATING 4
-
109
SEATING 5
-
LEA 191 SMITH STREET BROOKLYN, NEW YORK 11201
DRAWING:
FINISH SCHEDULE
ISSUE DATE :
03.12.2020 PROJECT NUMBER :
DRAWN BY :
CELINE LUI DRAWING :
2000 SEAL :
GENERAL FINISH NOTES
FINISH ABBREVIATIONS
1. Reference the Interior Elevations for additional finish information.
FLOOR
2. Clear Sealer to be applied at all concrete slabs exposed to view.
LCT CARP CT CRK EX'G RF WD
3. All gypsum board partitions and ceilings shall be covered by latex primer and three(3) coats of acrylic latex paint (semi-gloss); typical unless otherwise noted.
BASE Lightweight Concrete Topping Carpet Ceramic Tile, Thinset Cork Flooring Existing to Remain Resilient Flooring Wood Flooring
CT SRWB S.STL VBC VBS WB
WALLS Ceramic Tile, Coved Semi-Recessed Wood Base Stainless Steel Base Vinyl Base, Cove Vinyl Base, Straight Surface Applied Wood Base
BPG CT EX'G GL GWB HOM P-LAM
CEILINGS Back Painted Glass Ceramic Tile Existing to Remain Glass Gypsum Wall Board Homasote, Sanded Plastic Laminate
BOS SAC SAP GWB
Bottom of Structure Suspended Acoustic Ceiling Suspended Acoustic Plank Ceiling Suspended Gypsum Board Ceiling
DOB JOB NUMBER :
DOCUMENT :
01 DRAWING NUMBER:
A-920.00 S SCAN STICKER: