CME M-Key User's Manual

Page 1

CMG M-Key Ultra-thin MIDI Keyboard User's manual Model: M-Key Read "Precautions" onibaqe 5 before use

(VerO4)

Please read this manual carefully before use. Please keep this manual for reference.


Thank you for choosing CME M-Key — Ultra-thin MIDI Keyborad

Please keep all the important information here Attach your invoice or receipt here

..(_r_.cf.r.D.?...._ i Purchase

I Dealer's [Dealer's tel.

date [ Serialfon

name

the

back

angj

of

the

keyboard) !

addr.! 1

Warning: •

Improper connection may cause damage to the device.

Copyright

Copyright of the manual belongs to Central Music Co. Anyone must get a written permission from Central Music Co. before copying any part of the manual to any kind of media.

© Central Music Co. 2007

Package list Please check all the items in the product package: • • •

Ultra-thin MIDI keyboard 1 pcs USB cable 1 pcs User's manual 1 pcs


Special Message Section This product utilizes batteries or an external power supply (adapter). Do NOT connect this product to any power supply or adapter other than one described in the manual, on the product, or specifically recommended by CME.

WARNING: Do not place this product in a position where anyone could walk on, trip over, or roll anything over power or connecting cords of any kind. The use of an extension cord is not recommended I If you must use an extension cord, make sure that the cord has the ability to handle maximum current needed by this product. Please consult a local electrician when possible.

This product should be used only with the components CME.

When

supplied used

or with

recommended any

by

components,

please observe all safety markings and instructions that accompany the accessory product. SPECIFICATIONS SUBJECT TO CHANGE: The information contained in this manual is believed to be correct at the time of printing. However, CME reserves the right to change or modify any of the specifications without notice or obligation to update existing units. This product, either alone or in combination with an amplifier and headphones or speakers), may be capable of producing sound levels that could cause permanent hearing loss. Do NOT operate for long periods of time at a high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult an audiologist. IMPORTANT: The louder the sound, the shorter the time period before damage occurs.

Some CME products may have stands and/or accessory mounting fixtures that are either supplied with the product or as optional accessories. Some of these items are designed to be dealer assembled or installed. Please make sure that stands are stable and any optional fixtures (where applicable) are well secured BEFORE using.

Stands supplied by CME are designed for the respect products recommended.

only.

No

other

uses

are

NOTICE:

Service charges incurred due to a lack of knowledge relating to how a function or effect works (when the unit is operating as designed)

are not covered by the manufacturer's warranty, and are therefore the owners responsibility. Please study this manual carefully and consult your dealer before requesting service. ENVIRONMENTAL ISSUES: CME strives to produce products that are both user safe and environmentally friendly. We sincerely believe that our products and the production methods used to produce them, meet these goals. In keeping with both the letter and the spirit of the law, we want you to be aware of the following:

Battery Notice: This product MAY contain a small non-rechargeable battery which (if applicable) is soldered in place. The average life span of this type of battery is approximately five years. When replacement becomes necessary, contact a qualified service representative to perform the replacement. This product may also use "household" type batteries. Some of these may be rechargeable. Make sure that the battery being charged is a rechargeable type and that the charger is intended for the battery being charged.

When installing batteries, do not mix batteries with new, or with batteries of different type. Batteries MUST be installed correctly. Mismatches of incorrect installation may result in overheating and battery case rupture. Warning:

Do not attempt to disassemble, or incinerate any battery. Keep all batteries away from children. Dispose of used batteries promptly and as regulated by the laws in your area. Note: Check with any retailer of household type batteries in your area for battery disposal information. Disposal Notice:

Should this product become damaged beyond repair, or for some reason its useful life is considered to be at an end, please observe all local, state, and federal regulations that relate to the disposal of products that contain lead, batteries, plastics, etc. If your dealer is unable to assist you, please contact CME directly.


FCC INFORMATION (U.S.A) 1.

IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual,

meets FCC requirements. Modifications not expressly approved by CME may void your authority, granted by the FCC, to use the product. 2.

IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable(s) supplied with this product MUST be

used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA. 3.

NOTE: This product has been tested and found to comply with the limits for a Class B Digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide

reasonable

protection

against

harmful

interference

in

a

residential

environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur

in all installations. If this product is found to be the source of interference, which can

be determined by turning the unit "OFF" and "ON", please try to eliminate the problems by using one of the following measures:

Relocate either this product or the device that is being affected by the interference.

Utilize power outlets that are on different branch (circuit breaker or fuse) circuits or install AC line filter(s).

In the case of radio or TV interference, relocate/reorient the antenna. If the antenna

lead-in is 300 ohm ribbon lead, change the lead-in to co-axial type cable.

if these corrective measures do not produce satisfactory results, please contact the local retailer authorized to distribute this type of product. If you cannot locate the appropriate retailer, please contact CME.

The above statements apply ONLY to those products distributed in the USA.


PRECAUTIONS IMPORTANT

Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, damages, fire or other hazards. These precautions

include, but are not limited to, the follows: 1.

Read and understand all the instructions.

2.

Always follow the instructions on the instrument.

3.

Before cleaning the instrument, always remove the electric plug from the outlet as well as the USB cable. When cleaning, use a soft and dry cloth. Do not use gasoline, alcohol, acetone, turps or any other organic solutions; do not use liquid cleaner, spray

cleaner or too wet cloth. 4.

Do not use the instrument near water or moisture, such as bathtub, washbasin,

washing poor in the kitchen or similar places. 5.

Do not place the instrument in an unstable position where it might accidentally fall over.

6.

Do not jam sinks or holes of the instrument; those sinks of holes are used for air

circulation to prevent the instrument from overheating. Do not place the instrument near heat sink or any places with poor air circulation. 7.

Do not place anything on the power cord. Make sure the power cord is set on a safe

place, so nobody will step on it and no body will

trip over it.

8.

Do not overload the outlet and the AC cable to avoid fire or electrical shock.

9.

Do not insert anything in the instrument, which may cause fire or electrical shock. Do not splash any kind of liquid to the instrument.

10. Do not disassemble the instrument in case of accidental electrical shock.

11. Always take the instrument to a qualified service center in need of repair. You will cause yourself in danger if you open or remove the cover, and improper assembly may cause electrical shock in the future use.

12. Unplug all the connectors and take the instrument to a qualified service center if anything in the below listed happens:

A. The power cord or connector get hurt or worn out. B.

Any liquid get in the instrument.

C. The instrument gets rain or water splash.

D. The instrument does not work properly after following all the instructions regarding to the trouble shootings.

E.

The instrument falls down or gets broken.

F.

The instrument functions poorly.

13. Do not use the instrument when thundering; otherwise the thundering may cause long-distance electrical shock.

14. Do not use the instrument when there is a gas leak nearby. Keep this manual in safe place


CAUTION: Setting up

Do not connect the instrument when thundering.

Do not set up the cord or outlet to a moist place, except for that the outlet is specially designed for moist places.

When the power cord is connected to the AC outlet, do not touch the naked part of the cord or the connector.

Always follow the instructions carefully when setting up the product.

Avoid using any extending USB cable with poor quality or too long extending USB cable.

Do not use USB HUB to connect the product.

Make sure the computer USB port has adequate power supply, otherwise the product does not work properly.

WARNING: •

Do not expose the instrument to rain or moisture, to avoid fire or electrical shock.

Other precautions: •

Keep the instrument away from electrical interface sources, such as fluorescent light and electrical motors.

Keep the instrument away from dust, heat and vibration.

Do not expose the instrument to sunlight.

Do not place heavy objects on the instrument; do not place containers with liquid on the instrument.

Do not touch the connectors with wet hands

Central Music Co. is not responsible for any damage or data loss caused by improper operation to the instrument.

All the pictures in the manual are used for demonstration; they may be different from the real product.

Trade marks

CME and M-key are CME trade marks. Other brands and names belong to the respective owners.

Features M-key

49 notes ultra-thin full action semi-weighted keyboard, velocity sensitive

Assignable faders, joystick, pedal and other function buttons.

USB MIDI, class-compliant with Windows XP/Vista and Mac OS X


Content 1

General view 1.1 1.2

9

Front panel Rear panel

9 10

2

Installation guide 2.1 Power supply 2.2 Power on order

11 11 11

3 4

Connections Turning on 4.1 Normally turning on

12 13

4.2

5

4.3 Turning on with initialization Basic functions 5.1 Adjusting volume 5.2 Transpose and octave 5.3 Working with the joystick 5.4

5.5

6

13 14 14 14 15

,

Pedal

15

Selecting a voice 5.5.1 Bank MSB Select

15 15

5.5.2 5.5.3

15 16

Bank LSB Select Program Change

5.6

Keyboard Channel

16

5.7

Reset

16

8

ASSIGNING..... 6.1 Assigning Joystick 6.2 Assigning Slider 6.3 Assigning Pedal 6.4 Assigning DATA Button SYSTEM settings 7.1 Velocity Curve 7.2 Pedal Polarity 7.3 Pedal Type 7.4 USB to MIDI Out Appendix

9 10 11

8.1 Assignable controller list 8.2 GM voice list 8.3 Velocity curve list 8.4 MIDI route Troubleshooting Specifications MIDI Implementation Chart

7

13 13

Driver installation

17 17 17 17 17 18 18 18 18 18 19

*

19 21 ..22 22

23 24 25


This page was intentionally left blank.


2 Installation guide 2.1 Power supply A%

1. 2. Bs

Use USB Power:

Make sure the power switch is set to OFF. Connect the product to the computer via USB cable. Use AC adapter Power:

1. Make sure the power switch is set to OFF. 2. Connect the AC adapter (optional) to the POWER IN port in the rear panel. 3. Make sure the AC requirement of the AC adapter is compliant with the local AC supply, then connect the AC adapter to the power supply outlet.

Make sure the AC requirement of the AC adapter is compliant with the local AC supply, otherwise it will cause severe damage to the AC adapter or the instrument, and it may cause electrical shock! Only the AC adapter designed for this product should be used. If you cannot find the right adapter or the adapter does not work, please contact local CME dealers. The usage of an improper adapter may cause fire or electrical shock! The AC adapter varies from country to country. If you take the product from one country to another, please make sure your AC adapter compliant with the local power supply. If you are not sure about the technical information for the power supply or the adapter, you can consult a qualified local electrical engineer.

2.2 Power on order When you have this product connected to a system, please set all the volume to minimum then follow the proper order to turn all the devices on: master MIDI device (which sends out MIDI data), slave MIDI device (which receives MIDI data), audio devices (mixer, amplifier, speakers). When you follow this order, all the signals (MIDI and audio) will go properly from the beginning to the end. If you will turn off the system, please follow the reverse order (turn off the audio devices first, then the MIDI deivces).

n


3 Connections Before you make these connections, please turn off all devices to avoid possible damage.

Please refer to the fig. below to make connections:

POWER

SOUND MODULE

PEDAL COMPUTER

12

PEDAL


4 luriiitig fri 4.1 Normally turning on Set the power switch on the rear panel to ON to turn on this product. By default, this product is set to work with WINDOWS XP / Mac OSX. To make it work with WINDOWS VISTA, please press down and hold the joystick and turn iton, and you will see the DATA button flashes for 5 times. To make it work with WINDOWS XP / Mac OSX again, please do the above operation again, and you will see the SHIFT button flashes for 5 times.

4.2 Driver installation After you connect this product to your computer via USB and turn the product on, the computer will find it device and install the driver automatically. You can plug and play this product on WINDOWS XP/VISTA or Mac OSX. When the driver installation is finished, this product will be recognized as the "USB Audio Device" or "CME M-KEY". The MIDI driver offers 1 USB IN and 1 USB OUT.

Sometimes you may need to restart your computer during the installation. Please follow the on-screen instructions.

driver

4.3 Turning on with initialization If you press and hold both [- DATA] and [DATA +] buttons while turning on this product, it will enter the initialization process and return to the normal mode after the initializing is finished.

The initializing operation will clear all the user settings, please be careful!

13


5 Basic functions 5.1 Adjusting volume You can use the slider to send the volume control message CC#7 to adjust volume. You can change the function of the slider by assigning it to another kind of MIDI message. (6.2)

5.2 Transpose and octave •

Octave

By default, you can use the [- DATA +] button for octave shift.

When the octave is shifted, the related button indicator will be on.

The octave shift range is -03~00~03. Press the two DATA buttons at the same time will set the octave shift to 00, and the indicator will be off.

You can use the keyboard function [Data Transpose],

[Data Bank MSB],

[Data Bank LSB], [Data Program], [Data Channel] to define the [- DATA +] buttons. •

Transpose:

Press and hold down the SHIFT button while use the [- DATA +] buttons,

can shift the keyboard pitch in semi-notes. When the transpose value is changed, the related button indicator will flash

You

slowly.

The transpose range is -12~00~12 semi-notes. Hold the SHIFT button and press the two DATA buttons at the same time will set the transpose to 00, and the indicator will be off. When both octave and transpose values are changed, the related buttons will flash quickly.

You can also use the keyboard function [Data Octave] and [Data Transpose] to set the octave/transpose value.

The default keyboard ranges of M-Key are listed below: Middle C

(C3 or MIDI note number 60)

14


5.3 Working with the joystick • • •

Move the joystick to the left/right to send the PITCHBEND message. Move the joystick upward to send CC#1 (MODULATION) message. Move the joystick downward to send the AFTER TOUCH message.

You can use the fASSIGN JOYSTICKJ command to define the downward joystick message. (6.1).

5.4 Pedal For the two pedal jacks, each one can be used for continuouls pedal (e.g volume pedal) or switch pedal (e.g sustain pedal). By default, PEDAL A is for sustain pedal and send CC#64 message, the data value is either 0 or 127(switch data); PEDAL B is for volume pedal and send CC#11 message, the data range is 0-127(continuous data). To change pedal type or polarity, please use the system settings function (7.2-7.3).

You can customize the MIDI data to be sent using the fASSIGN PEDAL J command (6.3).

5.5 Selecting a voice

5.5.1

Bank MSB Select

Operation: [SHIFT] oGl [Bank MSB Select] o [Set value] o [ENTER] MIDI message sent: CC#0 + CC#32 + Program Default value: 0

Value range: 0-127

In the above operation, ISHIFTJ means press the [SHIFTJ button and its indicator is on; G1_ [Bank MSB Select J means press the G1 key in the keyboard; fSet value Jmeans using the number keys in the keyboard to enter the value; fENTER J means press the ENTER key in the keyboard.

Before use the

{ENTER J key to confirm the operation, you can press the

fSHIFTJ button again to turn off its indicator, and the operation is cancelled. During the operation, the [SHIFT] indicator will flash to show the operation status: one time flash means data changed; two times flash means data

out-of-range and not changed; three times flash means data confirmed or sent.

5.5.2 Bank LSB Select •

Operation: [SHIFT] =>A1 [Bank LSB Select] => [Set value] ■* [ENTER] 15


MIDI message sent: CC#O + CC#32 + Program

Default value: 0

Value range: 0-127

5.5.3 Program Change •

Operation: [SHIFT] ■=>£! [Program Change] ■=> [Set value] ■=> [ENTER]

MIDI message sent: CC#0 + CC#32 + Program

Default value: 1

Value range:

1-128

You can finish setting all the three values then press fENTER Jto send the data.

5.6 Keyboard Channel •

Operation: [SHIFT] <>AM [Keyboard Channel] o [Set value] ■=> [ENTER]

Default value:

Value range:

1 1-16

The keyboard channel also affect the MIDI channel of the joystick, pedals and slider.

5.7 Reset •

You can reset the external MIDI device by sending a MIDI reset message. MIDI message sent Key Name GMOn

B2

F0 7E 7F 09 01 F7

GM2On Reset All Control

C3 C#3

CC#121

GSOn

D3

F0 41 10 42 12 40 00 7F 00 41 F7

All Notes Off

D#3

CC#123

XGOn

E3

F0 4310 4C00 00 7E00F7

CMEOn

F3

F0 00 20 63 00 00 00 00 7F F7

•\

F0 7E 7F 09 03 F7

Please make sure your MIDI device support the related MIDI reset message before using this function.

16


8 Appendix 8.1 Assignable controller list Gontf

Name

000

Bank Select

067

Soft pedal on/off

001

Modulation wheel

068

Legato Footswitch

002

Breath control

069

Hold 2

003

Undefined

070

Sound Variation

004

Foot controller

071

Timbre/Harmonic Intens.

005

Portamento time

072

Release Time

006

Data Entry

073

Attack Time

007

Channel Volume

074

Brightness

008

Balance

075

Decay Time

009

Undefined

076

Vibrato Rate)

010

Pan

077

Vibrato Depth

011

Expression

078

Vibrato Delay

012

Effect control 1

079

Sound Cont.

013

Effect control 2

080-083

General Purpose

014-015

Undefined

084

Portamento Control

016-019

General Purpose

085-090

Undefined

020-031

Undefined

091

Reverb Send Level

032

Bank Select

092

Tremolo Depth

033

Modulation wheel

093

Chorus Send Level

034

Breath control

094

Celeste/Detune Depth

035

Undefined

095

Phaser Depth

036

Foot controller

096

Data entry +1

037

Portamento time

097

Data entry -1

038

Data entry

098

NRPN LSB

039

Channel Volume

099

NRPN MSB

040

Balance

100

RPN LSB

041

Undefined

101

RPN MSB

042

Pan

102-119

Undefined

043

Expression

120

All Sound Off

044

Effect control 1

121

Reset All Controllers

045

Effect control 2

122

Local control on/off

046-047

Undefined

123

All notes off

048-051

General Purpose

124

Omni mode off

052-063

Undefined

125

Omni mode on

064

Damper pedal

126

Poly mode off

065

Portamento on/off

127

Poly mode on

066

Sustenuto on/off

. :i.:;

;,\;\:-:-,'r-':;.'â– >::'*

19


146

**

163

After Touch

145

**

162

EG Release Time

144

**

161

EG Decay Time

143

••

160

EG Attack Time

142

**

159

EQ High Frequency

141

**

158

EQ Low Frequency

140

EQ High Gain

139

EQ Low Gain

138

High Pass Filter Cutoff Frequency

137

Low Pass Filter Resonance

136

Low Pass Filter Cutoff Frequency

135

Vibrato Delay

134

Vibrato Depth

133

Vibrato Rate

132

Coarse Tuning

131

148

Fine Tuning

130

147

Pitch Bend Sensitivity

129

Pitch Bend

128

149

**

*#

**

**

157

**

156

##

155

**

154

**

153

**

152

**

151

**

150

ProgramChange

Start (MTC) Continue (MTC)

Stop (MTC) System Reset (MTC)

Stop (MMC) PLAY (MMC) DEFERRED PLAY

FORWARD (MMC) REWIND (MMC) RECORD STROBE (MMC) RECORD EXIT (MMC)

RECORD PAUSE (MMC)

PAUSE (MMC) EJECT (MMC) CHASE (MMC) COMMAND ERROR RESET (MMC) MMC RESET (MMC)

* Those controllers cannot be assigned to the joystick. ** Those controllers cannot be assigned to the joystick or faders.

20


8.2 GM voice list Volce#

Name

Voice*

Name

VoIcg#

Name

Voice*

Name

001

GrandPno

033

Aco.Bass

065

SprnoSax

097

Rain

002

BritePno

034

FngrBass

066

Alto Sax

098

SoundTrk Crystal

003

EI.Grand

035

PickBass

067

TenorSax

099

004

HnkyTonk

036

Fretless

068

Bari.Sax

100

Atmosphr

005

E.Pianoi

037

SlapBasi

069

Oboe

101

Bright

006

E.Piano2

038

SlapBas2

070

Eng.Horn

102

Goblins

103

Echoes

007

Harpsi.

039

SynBassi

071

Bassoon

008

Clavi

040

SynBass2

072

Clarinet

104

Sd-Fi

009

Celesta

041

Violin

073

Piccolo

105

Sitar

010

Glocken

042

Viola

074

Flute

106

Banjo

011

MusicBox

043

Cello

075

Recorder

107

Shamisen

012

Vibes

044

Contrabs

076

PanFlute

108

Koto

013

Marimba

045

Trem.Str

077

Bottle

109

Kalimba

Shakhchi

110

Bagpipe

014

Xylophon

046

Pizz.Str

078

015

TubulBel

047

Harp

079

Whistle

111

Fiddle

016

Dulcimer

048

Timpani

080

Ocarina

112

Shanai

017

DrawOrgn

049

Stringsi

081

SquareLd

113

TnklBell

082

Saw Lead

114

Agogo

018

PercOrgn

050

Strings2

019

RockOrgn

051

SynStri

083

CaliopLd

115

SteelDrm

020

ChrchOrg

052

SynStr2

084

ChiffLd

116

WoodBlok

021

ReedOrgn

053

ChiorAah

085

CharanLd

117

TaikoDrm

022

Acordion

054

VoiceOoh

086

Voice Ld

118

MelodTom

023

Harmnica

055

SynVoice

087

Fifth Ld

119

Syn Drum

024

TangoAcd

056

Orch.Hit

088

Bass&Ld

120

RevCymbl FretNoiz

025

NylonGtr

057

Trumpet

089

NewAgePad

121

026

SteelGtr

058

Trombone

090

Warm Pad

122

BrthNoiz

027

Jazz Gtr

059

Tuba

091

PolySyPd

123

Seashore

028

CleanGtr

060

Mute Trp

092

ChoirPad

124

Tweet

Telphone

029

Mute.Gtr

061

Fr. Horn

093

BowedPad

125

030

Ovrdrive

062

BrasSect

094

MetalPad

126

Helicptr

031

Dist.Gtr

063

SynBrssi

095

Halo Pad

127

Applause

032

GtrHarmo

064

SynBrss2

096

SweepPad

128

Gunshot

21

I


8.3 Velocity curve list Velocity Curve 1 (Normal)

Velocity Curve (Soft) 127

. •

084

000

000

127

084

Velocityf Curve 3 (Hard)

(:!:! 1. .i. w H4- ■

px:

lit: i' ■■

Velocity Curve 4 (Expand)

■ I-..

tftr

J^'i.;j; ;■; /r::::

jiTrr: :r:r:::::;:: r:;-

064

'• • ■

i-t — '''" ! » I ..:

000 000

■ f

" ■ ! : ' i ' r ■ -

084

-

127

000

084

8.4 MIDI route "1

MIDI IN(To Sequencer) USB PORT A

KEYBOARD

16 CHANNELS

MIDI OUT(From Sequencer) USB PORT 16 CHANNELS

22


9 Troubleshooting Trouble with possible reasons and solution •

After turning on the power switch, the instrument is not powered on: 1.

Make sure the USB connection is made the the computer is on.

2.

Make sure the power connector is firmly connected to the power outlet.

3.

Check the power connectors.

No sound when playing the instrument

1.

Check the volume settings of the tone generator and speaker system

2.

Check the MIDI connection and the audio cable

3.

Check Master and Channel Volume faders

4.

Check Channel Expression Knobs

5.

Check the attack time of the filter

6.

Make sure you have the right settings in you music software

7.

Check the MIDI route settings

Continuous long sound:

1.

Check Sustain pedal (Damper pedal)

2.

Check the release time of the filter

3.

Use All notes off or Reset

Improper voice

1.

Tone generator not set properly, please Initialize or Reset..

Wrong pitch

1.

Check the transpose or octave settings.

2.

MIDI pitch is tuned.

3.

Pitch bend message not returned to default, please reset.

Some functions do not work 1.

Check the parts assigning.

2.

It is possible that your tone generator or music software does not support those

functions •

Cannot select voice Read the data list of your tone generator for voice select detail, and properly set the tone BANK MSB and LSB

23


10

Specifications

Keyboard 4-

M-Key: 49 keys(C1 - C5), (velocity sensitive)

Functions -0Basic functions: USB MIDI, Octave shift, Transpose, Joystick, Pedals, Breath control, MIDI OUT, Slider, Function buttons -> MIDI Data: Bank select, Program change, GM System On, GS System on, XG System On, Control change, All Notes Off, etc. 4Parameters: Transose, Octave, MIDI out channels, Velocity curve, Pitch bend, Moulation, Brightness, etc. Panel Controls and Indicators 4Function buttons with light x 2 <• Slider x 1, SHIFT button with light x 1 ■♦■ Joystick x 1 Display 4LED indicator for power/signal Input/Output Terminals 4 POWER ON/OFF switch x 1 <• POWER IN connector x 1 <«► USB port x1 <► PEDAL jack x 2 4MIDI OUT port x 1 Power Supply

4■♦•

USB bus power or AC Power Adapter (Optional) AC Power Adapter requirement: 9V 500mA

Dimensions (WxDxH) and Weight: <-

M-Key: 726.5 x 210x58.3 mm, 3.2 kg

* Specifications and appearance are subject to change without notice. 24


11

MIDI Implementation Chart

CME M-Key (MIDI KEYBOARD) Model: M-Key MIDI Implementation chart Function

Basic Channel

Default Changed

1 1-16

Mode

Default Messages Altered

X

X

***********

Number:

True voice

***********

Velocity

Note ON

ov=0~127

Note OFF

o v=0~127

Key's Ch's

X

Aftertouch

X X X

o

X X

Pitch Bend

o

X

Control Change

0-127

X

Prog Change:

o

X

True #

***********

o

o

System Real Time

Clock Commands

X o

X X

System command

Song position

X

X

Aux

Active Sense

X

X

System Exclusive

^j

X

0-127

Note

Ver. 1.0

Recognized

Transmitted

:

Messages o:Yes

X:No

CME is continually improving its products, and every attempt is made to ensure the information in the user's manual is current and accurate. However, CME will not be responsible for possible discrepancies between the manual and the real product.

25


CMG 2007-06

Central Music Co. Tel:+86-10-8580 1115 Fax:+86-10-85801114

Web: www.cme-pro.com E-mail for support: support@cme-pro.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.