CMG M-Key Ultra-thin MIDI Keyboard User's manual Model: M-Key Read "Precautions" onibaqe 5 before use
(VerO4)
Please read this manual carefully before use. Please keep this manual for reference.
Thank you for choosing CME M-Key — Ultra-thin MIDI Keyborad
Please keep all the important information here Attach your invoice or receipt here
..(_r_.cf.r.D.?...._ i Purchase
I Dealer's [Dealer's tel.
date [ Serialfon
name
the
back
angj
of
the
keyboard) !
addr.! 1
Warning: •
Improper connection may cause damage to the device.
Copyright
•
Copyright of the manual belongs to Central Music Co. Anyone must get a written permission from Central Music Co. before copying any part of the manual to any kind of media.
© Central Music Co. 2007
Package list Please check all the items in the product package: • • •
Ultra-thin MIDI keyboard 1 pcs USB cable 1 pcs User's manual 1 pcs
Special Message Section This product utilizes batteries or an external power supply (adapter). Do NOT connect this product to any power supply or adapter other than one described in the manual, on the product, or specifically recommended by CME.
WARNING: Do not place this product in a position where anyone could walk on, trip over, or roll anything over power or connecting cords of any kind. The use of an extension cord is not recommended I If you must use an extension cord, make sure that the cord has the ability to handle maximum current needed by this product. Please consult a local electrician when possible.
This product should be used only with the components CME.
When
supplied used
or with
recommended any
by
components,
please observe all safety markings and instructions that accompany the accessory product. SPECIFICATIONS SUBJECT TO CHANGE: The information contained in this manual is believed to be correct at the time of printing. However, CME reserves the right to change or modify any of the specifications without notice or obligation to update existing units. This product, either alone or in combination with an amplifier and headphones or speakers), may be capable of producing sound levels that could cause permanent hearing loss. Do NOT operate for long periods of time at a high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult an audiologist. IMPORTANT: The louder the sound, the shorter the time period before damage occurs.
Some CME products may have stands and/or accessory mounting fixtures that are either supplied with the product or as optional accessories. Some of these items are designed to be dealer assembled or installed. Please make sure that stands are stable and any optional fixtures (where applicable) are well secured BEFORE using.
Stands supplied by CME are designed for the respect products recommended.
only.
No
other
uses
are
NOTICE:
Service charges incurred due to a lack of knowledge relating to how a function or effect works (when the unit is operating as designed)
are not covered by the manufacturer's warranty, and are therefore the owners responsibility. Please study this manual carefully and consult your dealer before requesting service. ENVIRONMENTAL ISSUES: CME strives to produce products that are both user safe and environmentally friendly. We sincerely believe that our products and the production methods used to produce them, meet these goals. In keeping with both the letter and the spirit of the law, we want you to be aware of the following:
Battery Notice: This product MAY contain a small non-rechargeable battery which (if applicable) is soldered in place. The average life span of this type of battery is approximately five years. When replacement becomes necessary, contact a qualified service representative to perform the replacement. This product may also use "household" type batteries. Some of these may be rechargeable. Make sure that the battery being charged is a rechargeable type and that the charger is intended for the battery being charged.
When installing batteries, do not mix batteries with new, or with batteries of different type. Batteries MUST be installed correctly. Mismatches of incorrect installation may result in overheating and battery case rupture. Warning:
Do not attempt to disassemble, or incinerate any battery. Keep all batteries away from children. Dispose of used batteries promptly and as regulated by the laws in your area. Note: Check with any retailer of household type batteries in your area for battery disposal information. Disposal Notice:
Should this product become damaged beyond repair, or for some reason its useful life is considered to be at an end, please observe all local, state, and federal regulations that relate to the disposal of products that contain lead, batteries, plastics, etc. If your dealer is unable to assist you, please contact CME directly.
FCC INFORMATION (U.S.A) 1.
IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual,
meets FCC requirements. Modifications not expressly approved by CME may void your authority, granted by the FCC, to use the product. 2.
IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable(s) supplied with this product MUST be
used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA. 3.
NOTE: This product has been tested and found to comply with the limits for a Class B Digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable
protection
against
harmful
interference
in
a
residential
environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur
in all installations. If this product is found to be the source of interference, which can
be determined by turning the unit "OFF" and "ON", please try to eliminate the problems by using one of the following measures:
Relocate either this product or the device that is being affected by the interference.
Utilize power outlets that are on different branch (circuit breaker or fuse) circuits or install AC line filter(s).
In the case of radio or TV interference, relocate/reorient the antenna. If the antenna
lead-in is 300 ohm ribbon lead, change the lead-in to co-axial type cable.
if these corrective measures do not produce satisfactory results, please contact the local retailer authorized to distribute this type of product. If you cannot locate the appropriate retailer, please contact CME.
The above statements apply ONLY to those products distributed in the USA.
PRECAUTIONS IMPORTANT
Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, damages, fire or other hazards. These precautions
include, but are not limited to, the follows: 1.
Read and understand all the instructions.
2.
Always follow the instructions on the instrument.
3.
Before cleaning the instrument, always remove the electric plug from the outlet as well as the USB cable. When cleaning, use a soft and dry cloth. Do not use gasoline, alcohol, acetone, turps or any other organic solutions; do not use liquid cleaner, spray
cleaner or too wet cloth. 4.
Do not use the instrument near water or moisture, such as bathtub, washbasin,
washing poor in the kitchen or similar places. 5.
Do not place the instrument in an unstable position where it might accidentally fall over.
6.
Do not jam sinks or holes of the instrument; those sinks of holes are used for air
circulation to prevent the instrument from overheating. Do not place the instrument near heat sink or any places with poor air circulation. 7.
Do not place anything on the power cord. Make sure the power cord is set on a safe
place, so nobody will step on it and no body will
trip over it.
8.
Do not overload the outlet and the AC cable to avoid fire or electrical shock.
9.
Do not insert anything in the instrument, which may cause fire or electrical shock. Do not splash any kind of liquid to the instrument.
10. Do not disassemble the instrument in case of accidental electrical shock.
11. Always take the instrument to a qualified service center in need of repair. You will cause yourself in danger if you open or remove the cover, and improper assembly may cause electrical shock in the future use.
12. Unplug all the connectors and take the instrument to a qualified service center if anything in the below listed happens:
A. The power cord or connector get hurt or worn out. B.
Any liquid get in the instrument.
C. The instrument gets rain or water splash.
D. The instrument does not work properly after following all the instructions regarding to the trouble shootings.
E.
The instrument falls down or gets broken.
F.
The instrument functions poorly.
13. Do not use the instrument when thundering; otherwise the thundering may cause long-distance electrical shock.
14. Do not use the instrument when there is a gas leak nearby. Keep this manual in safe place
CAUTION: Setting up
Do not connect the instrument when thundering.
Do not set up the cord or outlet to a moist place, except for that the outlet is specially designed for moist places.
When the power cord is connected to the AC outlet, do not touch the naked part of the cord or the connector.
Always follow the instructions carefully when setting up the product.
Avoid using any extending USB cable with poor quality or too long extending USB cable.
Do not use USB HUB to connect the product.
Make sure the computer USB port has adequate power supply, otherwise the product does not work properly.
WARNING: •
Do not expose the instrument to rain or moisture, to avoid fire or electrical shock.
Other precautions: •
Keep the instrument away from electrical interface sources, such as fluorescent light and electrical motors.
•
Keep the instrument away from dust, heat and vibration.
•
Do not expose the instrument to sunlight.
•
Do not place heavy objects on the instrument; do not place containers with liquid on the instrument.
•
Do not touch the connectors with wet hands
•
Central Music Co. is not responsible for any damage or data loss caused by improper operation to the instrument.
•
All the pictures in the manual are used for demonstration; they may be different from the real product.
Trade marks
CME and M-key are CME trade marks. Other brands and names belong to the respective owners.
Features M-key
•
49 notes ultra-thin full action semi-weighted keyboard, velocity sensitive
•
Assignable faders, joystick, pedal and other function buttons.
•
USB MIDI, class-compliant with Windows XP/Vista and Mac OS X
Content 1
General view 1.1 1.2
9
Front panel Rear panel
9 10
2
Installation guide 2.1 Power supply 2.2 Power on order
11 11 11
3 4
Connections Turning on 4.1 Normally turning on
12 13
4.2
5
4.3 Turning on with initialization Basic functions 5.1 Adjusting volume 5.2 Transpose and octave 5.3 Working with the joystick 5.4
5.5
6
13 14 14 14 15
,
Pedal
15
Selecting a voice 5.5.1 Bank MSB Select
15 15
5.5.2 5.5.3
15 16
Bank LSB Select Program Change
5.6
Keyboard Channel
16
5.7
Reset
16
8
ASSIGNING..... 6.1 Assigning Joystick 6.2 Assigning Slider 6.3 Assigning Pedal 6.4 Assigning DATA Button SYSTEM settings 7.1 Velocity Curve 7.2 Pedal Polarity 7.3 Pedal Type 7.4 USB to MIDI Out Appendix
9 10 11
8.1 Assignable controller list 8.2 GM voice list 8.3 Velocity curve list 8.4 MIDI route Troubleshooting Specifications MIDI Implementation Chart
7
13 13
Driver installation
17 17 17 17 17 18 18 18 18 18 19
*
19 21 ..22 22
23 24 25
This page was intentionally left blank.
2 Installation guide 2.1 Power supply A%
1. 2. Bs
Use USB Power:
Make sure the power switch is set to OFF. Connect the product to the computer via USB cable. Use AC adapter Power:
1. Make sure the power switch is set to OFF. 2. Connect the AC adapter (optional) to the POWER IN port in the rear panel. 3. Make sure the AC requirement of the AC adapter is compliant with the local AC supply, then connect the AC adapter to the power supply outlet.
Make sure the AC requirement of the AC adapter is compliant with the local AC supply, otherwise it will cause severe damage to the AC adapter or the instrument, and it may cause electrical shock! Only the AC adapter designed for this product should be used. If you cannot find the right adapter or the adapter does not work, please contact local CME dealers. The usage of an improper adapter may cause fire or electrical shock! The AC adapter varies from country to country. If you take the product from one country to another, please make sure your AC adapter compliant with the local power supply. If you are not sure about the technical information for the power supply or the adapter, you can consult a qualified local electrical engineer.
2.2 Power on order When you have this product connected to a system, please set all the volume to minimum then follow the proper order to turn all the devices on: master MIDI device (which sends out MIDI data), slave MIDI device (which receives MIDI data), audio devices (mixer, amplifier, speakers). When you follow this order, all the signals (MIDI and audio) will go properly from the beginning to the end. If you will turn off the system, please follow the reverse order (turn off the audio devices first, then the MIDI deivces).
n
3 Connections Before you make these connections, please turn off all devices to avoid possible damage.
Please refer to the fig. below to make connections:
POWER
SOUND MODULE
PEDAL COMPUTER
12
PEDAL
4 luriiitig fri 4.1 Normally turning on Set the power switch on the rear panel to ON to turn on this product. By default, this product is set to work with WINDOWS XP / Mac OSX. To make it work with WINDOWS VISTA, please press down and hold the joystick and turn iton, and you will see the DATA button flashes for 5 times. To make it work with WINDOWS XP / Mac OSX again, please do the above operation again, and you will see the SHIFT button flashes for 5 times.
4.2 Driver installation After you connect this product to your computer via USB and turn the product on, the computer will find it device and install the driver automatically. You can plug and play this product on WINDOWS XP/VISTA or Mac OSX. When the driver installation is finished, this product will be recognized as the "USB Audio Device" or "CME M-KEY". The MIDI driver offers 1 USB IN and 1 USB OUT.
Sometimes you may need to restart your computer during the installation. Please follow the on-screen instructions.
driver
4.3 Turning on with initialization If you press and hold both [- DATA] and [DATA +] buttons while turning on this product, it will enter the initialization process and return to the normal mode after the initializing is finished.
The initializing operation will clear all the user settings, please be careful!
13
5 Basic functions 5.1 Adjusting volume You can use the slider to send the volume control message CC#7 to adjust volume. You can change the function of the slider by assigning it to another kind of MIDI message. (6.2)
5.2 Transpose and octave •
Octave
■
By default, you can use the [- DATA +] button for octave shift.
■
When the octave is shifted, the related button indicator will be on.
■
The octave shift range is -03~00~03. Press the two DATA buttons at the same time will set the octave shift to 00, and the indicator will be off.
You can use the keyboard function [Data Transpose],
[Data Bank MSB],
[Data Bank LSB], [Data Program], [Data Channel] to define the [- DATA +] buttons. •
Transpose:
■
Press and hold down the SHIFT button while use the [- DATA +] buttons,
■
can shift the keyboard pitch in semi-notes. When the transpose value is changed, the related button indicator will flash
You
slowly.
■
The transpose range is -12~00~12 semi-notes. Hold the SHIFT button and press the two DATA buttons at the same time will set the transpose to 00, and the indicator will be off. When both octave and transpose values are changed, the related buttons will flash quickly.
You can also use the keyboard function [Data Octave] and [Data Transpose] to set the octave/transpose value.
The default keyboard ranges of M-Key are listed below: Middle C
(C3 or MIDI note number 60)
14
5.3 Working with the joystick • • •
Move the joystick to the left/right to send the PITCHBEND message. Move the joystick upward to send CC#1 (MODULATION) message. Move the joystick downward to send the AFTER TOUCH message.
You can use the fASSIGN JOYSTICKJ command to define the downward joystick message. (6.1).
5.4 Pedal For the two pedal jacks, each one can be used for continuouls pedal (e.g volume pedal) or switch pedal (e.g sustain pedal). By default, PEDAL A is for sustain pedal and send CC#64 message, the data value is either 0 or 127(switch data); PEDAL B is for volume pedal and send CC#11 message, the data range is 0-127(continuous data). To change pedal type or polarity, please use the system settings function (7.2-7.3).
You can customize the MIDI data to be sent using the fASSIGN PEDAL J command (6.3).
5.5 Selecting a voice
5.5.1
Bank MSB Select
Operation: [SHIFT] oGl [Bank MSB Select] o [Set value] o [ENTER] MIDI message sent: CC#0 + CC#32 + Program Default value: 0
Value range: 0-127
In the above operation, ISHIFTJ means press the [SHIFTJ button and its indicator is on; G1_ [Bank MSB Select J means press the G1 key in the keyboard; fSet value Jmeans using the number keys in the keyboard to enter the value; fENTER J means press the ENTER key in the keyboard.
Before use the
{ENTER J key to confirm the operation, you can press the
fSHIFTJ button again to turn off its indicator, and the operation is cancelled. During the operation, the [SHIFT] indicator will flash to show the operation status: one time flash means data changed; two times flash means data
out-of-range and not changed; three times flash means data confirmed or sent.
5.5.2 Bank LSB Select •
Operation: [SHIFT] =>A1 [Bank LSB Select] => [Set value] ■* [ENTER] 15
•
MIDI message sent: CC#O + CC#32 + Program
•
Default value: 0
•
Value range: 0-127
5.5.3 Program Change •
Operation: [SHIFT] ■=>£! [Program Change] ■=> [Set value] ■=> [ENTER]
•
MIDI message sent: CC#0 + CC#32 + Program
•
Default value: 1
•
Value range:
1-128
You can finish setting all the three values then press fENTER Jto send the data.
5.6 Keyboard Channel •
Operation: [SHIFT] <>AM [Keyboard Channel] o [Set value] ■=> [ENTER]
•
Default value:
•
Value range:
1 1-16
The keyboard channel also affect the MIDI channel of the joystick, pedals and slider.
5.7 Reset •
You can reset the external MIDI device by sending a MIDI reset message. MIDI message sent Key Name GMOn
B2
F0 7E 7F 09 01 F7
GM2On Reset All Control
C3 C#3
CC#121
GSOn
D3
F0 41 10 42 12 40 00 7F 00 41 F7
All Notes Off
D#3
CC#123
XGOn
E3
F0 4310 4C00 00 7E00F7
CMEOn
F3
F0 00 20 63 00 00 00 00 7F F7
•\
F0 7E 7F 09 03 F7
Please make sure your MIDI device support the related MIDI reset message before using this function.
16
8 Appendix 8.1 Assignable controller list Gontf
Name
000
Bank Select
067
Soft pedal on/off
001
Modulation wheel
068
Legato Footswitch
002
Breath control
069
Hold 2
003
Undefined
070
Sound Variation
004
Foot controller
071
Timbre/Harmonic Intens.
005
Portamento time
072
Release Time
006
Data Entry
073
Attack Time
007
Channel Volume
074
Brightness
008
Balance
075
Decay Time
009
Undefined
076
Vibrato Rate)
010
Pan
077
Vibrato Depth
011
Expression
078
Vibrato Delay
012
Effect control 1
079
Sound Cont.
013
Effect control 2
080-083
General Purpose
014-015
Undefined
084
Portamento Control
016-019
General Purpose
085-090
Undefined
020-031
Undefined
091
Reverb Send Level
032
Bank Select
092
Tremolo Depth
033
Modulation wheel
093
Chorus Send Level
034
Breath control
094
Celeste/Detune Depth
035
Undefined
095
Phaser Depth
036
Foot controller
096
Data entry +1
037
Portamento time
097
Data entry -1
038
Data entry
098
NRPN LSB
039
Channel Volume
099
NRPN MSB
040
Balance
100
RPN LSB
041
Undefined
101
RPN MSB
042
Pan
102-119
Undefined
043
Expression
120
All Sound Off
044
Effect control 1
121
Reset All Controllers
045
Effect control 2
122
Local control on/off
046-047
Undefined
123
All notes off
048-051
General Purpose
124
Omni mode off
052-063
Undefined
125
Omni mode on
064
Damper pedal
126
Poly mode off
065
Portamento on/off
127
Poly mode on
066
Sustenuto on/off
. :i.:;
;,\;\:-:-,'r-':;.'â&#x2013; >::'*
19
146
•
**
163
After Touch
145
**
162
EG Release Time
144
**
161
EG Decay Time
143
••
160
EG Attack Time
142
**
159
EQ High Frequency
141
**
158
EQ Low Frequency
140
EQ High Gain
139
EQ Low Gain
138
High Pass Filter Cutoff Frequency
137
Low Pass Filter Resonance
136
Low Pass Filter Cutoff Frequency
135
Vibrato Delay
134
Vibrato Depth
133
Vibrato Rate
132
Coarse Tuning
131
148
Fine Tuning
130
147
Pitch Bend Sensitivity
129
Pitch Bend
128
149
**
*#
**
**
157
**
156
##
155
**
154
**
153
**
152
**
151
**
150
ProgramChange
Start (MTC) Continue (MTC)
Stop (MTC) System Reset (MTC)
Stop (MMC) PLAY (MMC) DEFERRED PLAY
FORWARD (MMC) REWIND (MMC) RECORD STROBE (MMC) RECORD EXIT (MMC)
RECORD PAUSE (MMC)
PAUSE (MMC) EJECT (MMC) CHASE (MMC) COMMAND ERROR RESET (MMC) MMC RESET (MMC)
* Those controllers cannot be assigned to the joystick. ** Those controllers cannot be assigned to the joystick or faders.
20
8.2 GM voice list Volce#
Name
Voice*
Name
VoIcg#
Name
Voice*
Name
001
GrandPno
033
Aco.Bass
065
SprnoSax
097
Rain
002
BritePno
034
FngrBass
066
Alto Sax
098
SoundTrk Crystal
003
EI.Grand
035
PickBass
067
TenorSax
099
004
HnkyTonk
036
Fretless
068
Bari.Sax
100
Atmosphr
005
E.Pianoi
037
SlapBasi
069
Oboe
101
Bright
006
E.Piano2
038
SlapBas2
070
Eng.Horn
102
Goblins
103
Echoes
007
Harpsi.
039
SynBassi
071
Bassoon
008
Clavi
040
SynBass2
072
Clarinet
104
Sd-Fi
009
Celesta
041
Violin
073
Piccolo
105
Sitar
010
Glocken
042
Viola
074
Flute
106
Banjo
011
MusicBox
043
Cello
075
Recorder
107
Shamisen
012
Vibes
044
Contrabs
076
PanFlute
108
Koto
013
Marimba
045
Trem.Str
077
Bottle
109
Kalimba
Shakhchi
110
Bagpipe
014
Xylophon
046
Pizz.Str
078
015
TubulBel
047
Harp
079
Whistle
111
Fiddle
016
Dulcimer
048
Timpani
080
Ocarina
112
Shanai
017
DrawOrgn
049
Stringsi
081
SquareLd
113
TnklBell
082
Saw Lead
114
Agogo
018
PercOrgn
050
Strings2
019
RockOrgn
051
SynStri
083
CaliopLd
115
SteelDrm
020
ChrchOrg
052
SynStr2
084
ChiffLd
116
WoodBlok
021
ReedOrgn
053
ChiorAah
085
CharanLd
117
TaikoDrm
022
Acordion
054
VoiceOoh
086
Voice Ld
118
MelodTom
023
Harmnica
055
SynVoice
087
Fifth Ld
119
Syn Drum
024
TangoAcd
056
Orch.Hit
088
Bass&Ld
120
RevCymbl FretNoiz
025
NylonGtr
057
Trumpet
089
NewAgePad
121
026
SteelGtr
058
Trombone
090
Warm Pad
122
BrthNoiz
027
Jazz Gtr
059
Tuba
091
PolySyPd
123
Seashore
028
CleanGtr
060
Mute Trp
092
ChoirPad
124
Tweet
Telphone
029
Mute.Gtr
061
Fr. Horn
093
BowedPad
125
030
Ovrdrive
062
BrasSect
094
MetalPad
126
Helicptr
031
Dist.Gtr
063
SynBrssi
095
Halo Pad
127
Applause
032
GtrHarmo
064
SynBrss2
096
SweepPad
128
Gunshot
21
I
8.3 Velocity curve list Velocity Curve 1 (Normal)
Velocity Curve (Soft) 127
. •
084
000
000
127
084
Velocityf Curve 3 (Hard)
(:!:! 1. .i. w H4- ■
px:
lit: i' ■■
Velocity Curve 4 (Expand)
■ I-..
tftr
J^'i.;j; ;■; /r::::
jiTrr: :r:r:::::;:: r:;-
064
'• • ■
i-t — '''" ! » I ..:
000 000
■ f
" ■ ! : ' i ' r ■ -
084
-
127
000
084
8.4 MIDI route "1
MIDI IN(To Sequencer) USB PORT A
KEYBOARD
16 CHANNELS
MIDI OUT(From Sequencer) USB PORT 16 CHANNELS
22
9 Troubleshooting Trouble with possible reasons and solution •
•
•
•
•
•
After turning on the power switch, the instrument is not powered on: 1.
Make sure the USB connection is made the the computer is on.
2.
Make sure the power connector is firmly connected to the power outlet.
3.
Check the power connectors.
No sound when playing the instrument
1.
Check the volume settings of the tone generator and speaker system
2.
Check the MIDI connection and the audio cable
3.
Check Master and Channel Volume faders
4.
Check Channel Expression Knobs
5.
Check the attack time of the filter
6.
Make sure you have the right settings in you music software
7.
Check the MIDI route settings
Continuous long sound:
1.
Check Sustain pedal (Damper pedal)
2.
Check the release time of the filter
3.
Use All notes off or Reset
Improper voice
1.
Tone generator not set properly, please Initialize or Reset..
Wrong pitch
1.
Check the transpose or octave settings.
2.
MIDI pitch is tuned.
3.
Pitch bend message not returned to default, please reset.
Some functions do not work 1.
Check the parts assigning.
2.
It is possible that your tone generator or music software does not support those
functions •
Cannot select voice Read the data list of your tone generator for voice select detail, and properly set the tone BANK MSB and LSB
23
10
Specifications
Keyboard 4-
M-Key: 49 keys(C1 - C5), (velocity sensitive)
Functions -0Basic functions: USB MIDI, Octave shift, Transpose, Joystick, Pedals, Breath control, MIDI OUT, Slider, Function buttons -> MIDI Data: Bank select, Program change, GM System On, GS System on, XG System On, Control change, All Notes Off, etc. 4Parameters: Transose, Octave, MIDI out channels, Velocity curve, Pitch bend, Moulation, Brightness, etc. Panel Controls and Indicators 4Function buttons with light x 2 <• Slider x 1, SHIFT button with light x 1 ■♦■ Joystick x 1 Display 4LED indicator for power/signal Input/Output Terminals 4 POWER ON/OFF switch x 1 <• POWER IN connector x 1 <«► USB port x1 <► PEDAL jack x 2 4MIDI OUT port x 1 Power Supply
4■♦•
USB bus power or AC Power Adapter (Optional) AC Power Adapter requirement: 9V 500mA
Dimensions (WxDxH) and Weight: <-
M-Key: 726.5 x 210x58.3 mm, 3.2 kg
* Specifications and appearance are subject to change without notice. 24
11
MIDI Implementation Chart
CME M-Key (MIDI KEYBOARD) Model: M-Key MIDI Implementation chart Function
Basic Channel
Default Changed
1 1-16
Mode
Default Messages Altered
X
X
***********
Number:
True voice
***********
Velocity
Note ON
ov=0~127
Note OFF
o v=0~127
Key's Ch's
X
Aftertouch
X X X
o
X X
Pitch Bend
o
X
Control Change
0-127
X
Prog Change:
o
X
True #
***********
o
o
System Real Time
Clock Commands
X o
X X
System command
Song position
X
X
Aux
Active Sense
X
X
System Exclusive
^j
X
0-127
Note
Ver. 1.0
Recognized
Transmitted
:
Messages o:Yes
X:No
CME is continually improving its products, and every attempt is made to ensure the information in the user's manual is current and accurate. However, CME will not be responsible for possible discrepancies between the manual and the real product.
25
CMG 2007-06
Central Music Co. Tel:+86-10-8580 1115 Fax:+86-10-85801114
Web: www.cme-pro.com E-mail for support: support@cme-pro.com