DRAWING REGISTER Subset Name
Sheet No. ID Layout
Drawing Scales
Drawing Layout Name
COVER PAGES
A00
DRAWING REGISTER
1:1
COVER PAGES
A01
GENERAL NOTES
1:50
SITE & LOCALITY
A102
SITE & SETOUT PLAN
1:200
GENERAL ARRANGEMENT
A200
EXISTING CONDITION & DEMOLITION PLAN
1:500
GENERAL ARRANGEMENT
A201
SLAB SET DOWN & PENETRATIONS -GROUND FLOOR
1:100
GENERAL ARRANGEMENT
A202
SLAB SET DOWN & PENETRATIONS -FIRST FLOOR
1:100
GENERAL ARRANGEMENT
A203
TYPICAL SLAB SET DOWN SECOND TO FIFTH FLOOR
1:100
GENERAL ARRANGEMENT
A204
GROUND FLOOR PLAN
1:100, 1:50
GENERAL ARRANGEMENT
A205
PARTITION PLAN -GROUND FLOOR
1:100, 1:50
GENERAL ARRANGEMENT
A206
REFLECTED CEILING PLAN -GROUND FLOOR
1:100
GENERAL ARRANGEMENT
A207
FIRST FLOOR PLAN
1:100, 1:50
GENERAL ARRANGEMENT
A208
PARTITION PLAN -FIRST FLOOR
1:100, 1:50
GENERAL ARRANGEMENT
A209
LEVEL 02-05 TYPICAL FLOOR PLAN
1:100, 1:50
GENERAL ARRANGEMENT
A210
TYPICAL PARTITION PLAN -SECOND TO FIFTH FLOOR
1:100
GENERAL ARRANGEMENT
A211
TYPICAL REFLECTED CEILING PLAN -FIRST TO FIFTH FLOOR
1:100
GENERAL ARRANGEMENT
A212
ROOF PLAN
1:100
ELEVATIONS & SECTIONS
A300
ELEVATION 01
1:100
ELEVATIONS & SECTIONS
A301
ELEVATION 02
1:100
ELEVATIONS & SECTIONS
A302
ELEVATION 03
1:100
ELEVATIONS & SECTIONS
A303
ELEVATION 04
1:100
ELEVATIONS & SECTIONS
A304
SECTION LATERAL
1:100
ELEVATIONS & SECTIONS
A305
SECTION LONGITUDINAL
1:100
ELEVATIONS & SECTIONS
A306
STAIR PLAN
1:50, 1:10
DETAILS
A400
SECTION DETAILS
1:10, 1:50
DETAILS
A401
SECTION & PLAN DETAILS
1:10, 1:50
WET AREAS
A420
GROUND FLOOR WET AREAS
1:50
WET AREAS
A421
TYPICAL APARTMENT WET AREAS
1:50
WET AREAS
A422
TYPICAL KITCHEN JOINERY
1:50
SCHEDULES
A700
WINDOW SCHEDULE
1:50 1:1
SCHEDULES
A701
DOOR SCHEDULE
1:50 1:1
3D PERSPECTIVE NORTH EAST VIEW OF PROJECT
3D PERSPECTIVE NORTH WEST VIEW OF PROJECT
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
DRAWING REGISTER
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:1
Date:
Project No:
Drawing No.:
02COMS4
A00
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 H:\2016\WORK DRAW S4\a19_S4_DES_02COMST4_16.3.23 -wed class print.pln
23/03/2016
PLUMMER STREET DEVELOPMENT, LOT SEVEN CONSTRUCTION ISSUE
Subset Name
DRAWING REGISTER Layout ID
Layout Name
COVER PAGES
A00
DRAWING REGISTER
COVER PAGES
A01
GENERAL NOTES
SITE & LOCALITY
A102
SITE & SETOUT PLAN
200 GENERAL ARRANGEMENT
A200
EXISTING CONDITION & DEMOLITION PLAN
200 GENERAL ARRANGEMENT
A201
SLAB SET DOWN & PENETRATIONS -GROUND FLOOR
200 GENERAL ARRANGEMENT
A202
SLAB SET DOWN & PENETRATIONS -FIRST FLOOR
200 GENERAL ARRANGEMENT
A203
TYPICAL SLAB SET DOWN SECOND TO FIFTH FLOOR
200 GENERAL ARRANGEMENT
A204
GROUND FLOOR PLAN
200 GENERAL ARRANGEMENT
A205
FIRST FLOOR PLAN
200 GENERAL ARRANGEMENT
A206
SECOND TO FIFTH TYPICAL FLOOR PLAN
200 GENERAL ARRANGEMENT
A207
PARTITION PLAN -GROUND FLOOR
200 GENERAL ARRANGEMENT
A208
SECOND TO FIFTH FLOORS TYPICAL PARTITION PLAN
200 GENERAL ARRANGEMENT
A209
REFLECTED CEILING PLAN -GROUND FLOOR
200 GENERAL ARRANGEMENT
A210
SECOND TO FIFTH FLOORS TYPICAL REFLECTED CEILING PLAN
200 GENERAL ARRANGEMENT
A211
ROOF PLAN
ELEVATIONS & SECTIONS
A300
ELEVATION 01
ELEVATIONS & SECTIONS
A301
ELEVATION 02
ELEVATIONS & SECTIONS
A302
ELEVATION 03
ELEVATIONS & SECTIONS
A303
ELEVATION 04
ELEVATIONS & SECTIONS
A304
SECTION LATERAL
ELEVATIONS & SECTIONS
A305
SECTION LONGITUDINAL
ELEVATIONS & SECTIONS
A306
STAIR PLAN
DETAILS
A400
SECTION DETAILS
DETAILS
A401
SECTION & PLAN DETAILS
WET AREAS
A500
GROUND FLOOR WET AREAS
WET AREAS
A501
TYPICAL APARTMENT WET AREAS
WET AREAS
A502
TYPICAL KITCHEN JOINERY
600 SCHEDULES
A600
WINDOW SCHEDULE
600 SCHEDULES
A601
DOOR SCHEDULE 01
600 SCHEDULES
A602
DOOR SCHEDULE 02
3D PERSPECTIVE MODEL NORTH WEST VEIW
3D PERSPECTIVE MODEL NORTH EAST VEIW
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
DRAWING REGISTER
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:1
Date:
Project No:
Drawing No.:
02COMS4
A00
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
GENERAL NOTES All materials and work practices shall comply with, but not limited to the Building Regulations 2006, the National C0onstruction Code Series 2015 Building Code of Australia Volume 1 and all relevant current Australian standards (as amended) referred to therein. Unless otherwise specified, the term BCA shall refer to National Construction Code Series 2015 Building Code of Australia Volume 1. All materials and construction practice shall meet the Performance Requirements of the Building Code of Australia. Where an alternative solution is proposed then prior to implementation or installation it first must be assessed and approved by the Relevant Building Surveyor as meeting the Performance Requirements of the Building Code of Australia. Step sizes (other than for spiral stairs) to be: –– Risers (R) 190mm maximum and 115mm minimum –– Going (G) 355mm maximum and 250mm minimum for Public stairways and 355mm maximum and 240mm minimum for Private stairways –– 2R + 1G = 700mm maximum and 550mm minimum –– Constructed with a less than 125mm gap to open treads All treads, landings and the like to have a slip-resistance classification of P3 or R10 for dry surface conditions and P4 or R11 for wet surface conditions, or a nosing strip with a slip-resistance classification of P3 for dry surface conditions and P4 for wet surface conditions.
Provide barriers where change in level exceeds 1000mm above the surface beneath landings, ramps and/or treads. Barriers (other than tensioned wire barriers) to be: –– 1000mm minimum above finished surface level of balconies, landings or the like, and
Authorities List: Municipality_ _________________________________________________________________ Sewerage authority___________________________________________________________ Drainage authority____________________________________________________________ Relevant Building Surveyor_____________________________________________________ Relevant Fire Authority_ _______________________________________________________ Relevant Electrical Supply Authority____________________________________________
The Client and/or the Client’s Builder shall not modify or amend the plans without the knowledge and consent of [building designer’s name] except where a Registered Building Surveyor makes minor necessary changes to facilitate the Building Permit application and that such changes are promptly reported back to [building designer’s name]. The approval by this office of a substitute material, work practice, variation or the like is not an authorisation for its use or a contract variation. All variations must be accepted by all parties to the agreement and where applicable the Relevant Building Surveyor prior to implementing any variation.
Planning Permit: Planning Permit No___________________________________________________________ Issue Date____________________________________________________________________ Builder to allow for all works to comply and include all required conditions in accordance with the Planning Permit and shall be responsible for compliance with all Planning Conditions at the completion of works.
Refer to Civil Engineers design and details for all storm water, car parking and driveway construction requirements. Refer to fire services design for all hydrant, hose reels and extinguisher details. . Electrical switchboards located in the path of travel to exits to be enclosed in a metal or other non combustible cabinet with smoke proof doors. Significant switchboards shall be provided with a 5kg carbon dioxide extinguisher or another type of extinguisher with a minimum classification of 1A:E and fitted with a hose complete with extinguisher identification signage and shall be located between 2m and 20m from the significant switchboard.
Project Consultants List: Consulting Structural Engineer_________________________________________________ Consulting Civil Engineer_ _____________________________________________________ Consulting Fire Service Design_ ________________________________________________ Consulting Land Surveyor______________________________________________________ Consulting Geotechnical Engineer_____________________________________________ Consulting Landscape Designer_ ______________________________________________ Consulting Mechanical Services Engineer______________________________________ Consulting Electrical Engineer_________________________________________________ Consulting Hydraulic Engineer_________________________________________________ Consulting Lighting Designer___________________________________________________
Fire hazard properties of materials and assemblies to comply with BCA Specification C1.10. Mechanical ventilation or air-conditioning of rooms to be provided with a system complying with AS1668.2 and AS/ NZS 3666.1 as amended. Exhaust outlets to be located no closer than 6.0m to fresh air inlets. Sediment pollution control: –– A site management plan is to be implemented during construction to control sediment runoff in accordance with EPA Victoria publication #275 ‘construction techniques for sediment pollution control’. –– Provide ‘propex’ or written approved equivalent silt fences to the low side of the allotment and around all soil stockpiles and storm water inlet pits / sumps and install ‘silt stop’ filter bags over all storm water entry pits during construction works. –– ‘Supergro’ or written approved equivalent erosion control fabric to be placed over garden beds to prevent surface erosion during re vegetation period.
Site geotechnical investigation: Refer to geotechnical investigation report no__________________________________ By ___________________________________________________________________________
–– 865mm minimum above finished surface level of stair nosing or ramp, and –– Vertical with a less than 125mm gap between, and –– Any horizontal element within the barrier between 150mm and 760mm above the floor must not facilitate climbing where changes in level exceeds 4000mm above the surface beneath landings, ramps and/or treads.
WALL TYPES SCHEDULE
Top of hand rails to be minimum 865mm vertically above stair nosing and floor surface of ramps.
NOTE: REFER TO GENERAL NOTES REFER TO MANUFACTURES SPEC AND SHOP DRAWINGS
All measurements and levels in millimetres unless noted otherwise. Figured dimensions take precedence over scaled dimensions. The builder shall take all steps necessary to ensure the stability and general water tightness of all new and/ or existing structures and all essential services to be maintained during all works. The builder and subcontractors shall check and verify all dimensions, setbacks, levels and specifications and all other relevant documentation prior to the commencement of any works. Report all discrepancies to this office for clarification.
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
50 70 130 116
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT RIGID INSULATION & EXTERNAL CONCRETE LAYER INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
PLASTERBOARD 10mm STEEL STUD 92mm
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WALL TYPE 3 CURTAIN WALL
200
drawings/details and specifications and with any other written instructions issued in the course of the contract.
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
150
All storm water to be taken to the legal point of discharge to the relevant authorities’ approval. These drawings shall be read in conjunction with all architectural specifications, relevant structural and all other consultants’
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
PRECAST AS PER ENG SPEC.NATURAL FINISH.
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
50
Window sizes nominated are nominal only. Actual size may vary according to manufacturer. Windows to be flashed all around. Waterproofing of wet areas to comply with BCA Part F1.7 Buildings in marine or other exposure environments shall have masonry units, mortar and all built in components and the like complying with the durability requirements of AS3700-2011 Masonry structures.
SCALE 1:50
KINGSPAN INSULATED WALL PANEL 0.5mm STEEL MICRO RIB EXTERNAL FINSIH
Installation of all services shall comply with the respective Supply Authority requirements. The builder and subcontractor shall ensure that all storm water drains, sewer pipes and the like are located at a sufficient distance from any buildings footing and/or slab edge beams so as to prevent general moisture penetration, dampness, weakening and undermining of any building and its footing system. These plans have been prepared for the exclusive use by the client of [insert Building Designer] (‘the Designer’) for the purpose expressly notified to the Designer. Any other person who uses or relies on these plans without the Designer’s written consent does so at their own risk and no responsibility is accepted by the Designer for such use and/or reliance. THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
GENERAL NOTES
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:50
Date:
Project No:
Drawing No.:
02COMS4
A01
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
LOT 6/8 (KARAVE)
PROPOSED 6 STOREY RESIDENTAL BUILDING AND MIXED USE COMMERCIAL: RTO LEARNING CENTRE; RESTAURANT.
O/HO/H W W
CURTAIN WALL; PRECAST CONCRETE 25M HIGH FFL 4.5
1
2
3
8,000
8,000
4
5
8,000
6
8,000
PEDESTRIAN AND SLOW VEHICLE LANEWAY 6M WIDE ASPHALT RL 4.0
55.50 M
8,000
8,000
158º 58' 0" 4,000
ES 1 -RES ENTRY
LOT 7/8
GF PODIUM TRAFFICABLE GREEN ROOF AND COMMUNAL GARDEN AREA 260M2
≈25M HIGH
FFL 8.5
FFL 8.5 DP
LPOD
55.50 M
158º 58' 0"
DP
4,000
DP
DP
3 CONCRETE RAIN WATER TANKS LOCATED UNDERGROUND; 3450 DIA - REFER TO SPECIFICATION
1270M2
EXTERNAL STAIR
LOT 8/8
ES 1: 2R+G =640
(JOHN)
ES2: 2R+G =640
VEHICLE ROADWAYAND CARPARK ACCESS 15M WIDE ASPHALT
LEGEND
PROPOSED 6 STOREY RESIDENTIAL BUILDING AND MIXED USE COMMERCIA: CAFE; GROCER;CHILDCARE FACILITY
LP
CONCRETE KERB RL 4.00
A
PROPOSED FOOTPROINT 1100M2
ES 1 ES 2 ER 1 LPOD SP TP LP O/HW
SET OUT
DP
AREA ANALYSIS TOTAL SITE
GF ROOF TO BE LANDSCAPED WITH INDIGENOUS PLANTING 160M2
8,000
LANDSCAPING AREA (1200M WIDTH) TO NORTH EASTERN BOUNDARY WITH INDIGENOUS PLANTS
No. 345 EXISTING COMMERCIAL BUILDING CLUSTER DARK BLUE GLAZED CURTAIN WALL 5M HIGH;
22.89 M
DP
FFL 4.50
CARPARK FOR CAR AND MOTORCYCLE PARKING LOCATED WITHIN GROUND FLOOR OF BUILDING FOOTPRINT (G 08)
CONCRETE LANDING FFL 4.50
PROPOSED 6 STOREYMIXED USE COMMERCIAL AND RESIDENTAL BUILDING CURATIN WALL; PRECAST CONCRETE
EXISTING NATURE STRIP WITH PLANTED TREES TO REMAIN NGL 4.00
2000
1,500
68º 58' 0"
BIN COLLECTION AREA
O/H W
1,200
248º 58' 0"
320 -332 PLUMMER ST, PORT MELBOURNE
22.89 M
RAINWATER TANKS: TAYLEX PRECAST CONCRETE RAINWATER TANKS; INDIVIDUAL CAPACITY 22.5KL; WITH LIGHT TRAFFICABLE LID AND RISER FOR MAINTENENCE/INSPECTION
B
BICYCLE PARKING AREA
CONCRETE PAVED FOOTPATH TO BOUNDARY RL 4.00
8,000 7.5M EASEMENT
STORM WATER DRAINAGE SHALL BE CONNECTED TO THE LEGAL POINT OF DISCHARGE TO THE SATISFACTION OF ALL RELEVANT AUTHORITIES.
ES 2 -RETAIL ENTRY UA RAMP 1
DP
GENERAL NOTES
UP
PLUMMER ST
4.500
1,200
8,740
C
CROSS OVER
4,790
3 2 1
UP
PARALLEL STREET PARKING
3 2 1
D
LP
7
CURTAIN WALL, PRECAST CONCRETE 25M HIGH
RL 4.00
EXTERNAL STAIR 1 EXTERNAL STAIR 2 EXTERNAL RAMP LEGAL POINT OF DISCHARGE STORMWATER PIT TELECOM PIT (EXISTING) LIGHT POLE/POWER POLE OVER HEAD WIRES (EXISTING)
FFL 4.50 O/H W
No. 351 EXISTING BUILDING BRICK AND METAL SAW TOOTH ROOF; OPEN WORK YARD: 5M HIGH
CONCRETE PAVED FOOTPATH TO BOUNDARY RL 4.00
EXISTING NATURE STRIP WITH PLANTED TREES TO REMAIN NGL 4.00
LP
O/H W
O/H W
LP
LP
TP
CONCRETE KERB RL 4.00
SMITH ST OFF STREET PARKING
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SITE & SETOUT PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:200
Date:
Project No:
Drawing No.:
02COMS4
A102
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
PROHASKY ST PARALLEL STREET PARKING
O/H W
LP
O/H W
LP
O/H W
LP
NATURE STRIP CONCRETE FOOTPATH
63.0 M
NATURE STRIP
LP
158º 58' 0"
4.00
LP
74.18 M
74.18 M
No. 320 -LOT 1
No. 319 EXISTING COMMERCIAL BUILDING RENDERED CONCRETE 8M HIGH; SINGLE STOREY
NATURE STRIP
248º 58' 0"
68º 58' 0"
CONCRETE FOOTPATH
O/H W
EXISTING COMMERCIAL BUILDING TO BE REMOVED TO GROUND LEVEL AND CLEARED 20M HIGH 4454m2 BRICK, METAL CLAD, SAW TOOTH METAL ROOF EXISTING OPEN WORKYARD & CARPARK TO REMAIN
No. 327 EXISTING COMMERCIAL BUILDING RENDERED BLACK FACADE WALL & METAL PROFILED SHEET CLAD 8M HIGH; SINGLE STOREY
4.00
FENCED: METAL MESH WIRE WITH METAL BARS AND POSTS -2.5M HIGH
LP
NATURE STRIP
158º 58' 0"
63.0 M
ALL DEMOLITION AND REMOVAL WORKS ARE TO BE CARRIED OUT BY A LICENSED CONTRACTOR. CONTRACTOR IS TO REVIERW AND WHERE NECESSARY REVISE THE ASBESTOS REGISTER IF APPLICABLE. DEMOLITION MUST NOT BE COMMENCED UNITL THE PRECAUTIONARY MEASURES HAVE BEEN INSPECTED AND APPROVED BY THE RELEVANT BUILDING SURVEYOR; PRECAUTIONS MUST BE TAKEN BEFORE AND DURING DEMOLITION IN ACCORDANCE WITH AS 2601-2001.
O/H W
No. 332 -LOT 2
BRICK, METAL CLAD, SAW TOOTH METAL ROOF
68º 58' 0"
8062m2
O/H W LP
126.99 M
248º 58' 0"
20M HIGH
126.99 M
STORMWATER PIT TELECOM PIT (EXISTING) LIGHT POLE/POWER POLE OVER HEAD WIRES (EXISTING)
No. 343 EXISTING COMMERCIAL BUILDING RENDERED CONCRETE 5M HIGH
EXISTING COMMERCIAL BUILDING TO BE REMOVED TO GROUND LEVEL AND CLEARED
3.9 218 º 7 M 54'
LEGEND SP TP LP O/HW
NATURE STRIP
CONCRETE FOOTPATH
LP
GRASS TO BUILDING LINE
THE SITE AREA MUST BE CLEARED OF DEBRIS, TO GROUND LEVEL. ELEMENTS NOTED TO REMAIN, MUST BE PROTECTED.
PARALLEL STREET PARKING
DURING SITE WORKS STORMWATER MUST NOT BE CONCENTRATED ON TO AN ADJACENT PROPERTY/SITE AT ANY TIME.
TARVER ST
ALL EARTHWORKS SHALL BE CARRIED OUT IN ACCORDANCE WITH THE PROJECT GEOTECHNICAL REPRT AND RELEVANT AS AND NCC-2015.
No. 335 EXISTING COMMERCIAL BUILDING/WORKSHOP METAL PROFILED SHEET CLAD 10M HIGH; SINGLE STOREY
PLUMMER ST
No. 21 SMITH ST EXISTING COMMERCIAL BUILDING TO REMAIN 51.37 M 248º 58'
BRICK; METAL PROFILE SHEET CLAD 10M HIGH
4.00
PARALLEL STREET PARKING
THE BUILDER AND SUBCONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS, SETBACKS, LEVELS AND SPECIFICATIONS AND ALL OTHER RELEVANT DOCUMENTATION PRIOR TO THE COMMENCEMENT OF ANY WORKS.
NATURE STRIP
DEMOLITION NOTES
No. 345 EXISTING COMMERCIAL BUILDING CLUSTER DARK BLUE GLAZED CURTAIN WALL 5M HIGH;
LP
17.39 M 248º 58'
2.0 233 º 9 M 25'
F. HYDRANT
EASEMENT LP
O/H W No. 351 EXISTING BUILDING BRICK AND METAL SAW TOOTH ROOF; OPEN WORK YARD: 5M HIGH
4.00 63.0 M O/H W
158º 58' 0"
NATURE STRIP TP
LP
LP
SMITH ST OFF STREET PARKING
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
EXISTING CONDITION & DEMOLITION PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:500
Date:
Project No:
Drawing No.:
02COMS4
A200
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
5,500
8,000
8,000
8,000
5,130
5,390
4,130
2,870 225
775
1,974
450
BICYCLE ACCESS FROM LANEWAY TO CARPARK PEDESTRIAN FOOTPATH
896
1,250
3,175
DG.22
DG.21
900
DG.23
1,118
900
1,500
CC.D5
CC.D6
20
20
DG.02
WT 1
CC.C7
FW
1,547 494
2,060
LIFT VOID
OT
1,094 120
640
WG.01
R
CC.C7
WG.02
618
50 R FW
552
3,820
OT
R
DG.03
SSL 4.5
OT
3,600
R
8,000
OT
50
OT OT
FW 88
DG.15
SSL 4.0
5,940
3,690
CC.C5
CC.C7
2,060
8,000
STRIP DRAIN TRENCH DEPTH 300mm
650
3,132
CC.C3
STRIP DRAIN TRENCH DEPTH 300mm
2,731
SSL 4.5
DG.16
OT
350
20
SSL 4.0 CC.C2
196 90
3,714
STRIP DRAIN TRENCH DEPTH 300mm
500
124
DG.17
1,369294
2,101
182 1,648
1,617
OT
4,670
DG.19
CC.C1
480
DG.20
FIRE RATED MAINS RISER
SSL 4.5
OT
3,700
FIRE RATED COMMS RISER
500
CC.D3
2,083
450
CC.D2
6,750
201
FIRE RATEED GAS RISER DG.18
8,000
8,000
6,460
WT 4
1,090
570 3,700 520
4,790
C
CC.D1
3,970
1,540
7
8,000
4,030
DG.35
D
6
200
110
8,000
5
582 1,508
115
5,500
4
3,696
535
3
124
2
1,076
1
CC.B4
OT
OT
FW
CC.B7
50
OT
1,180
R
WG.03
CC.B6
R OT
3,175
CC.B2
2,021
CC.B1
CC.B3
1,455 427
B
CC.B5
1,930
618
DG.04 OT
DG.13
20
SSL 4.0
SSL 4.5
500
1,830
1,649
WG.04
600
50
FW
FW
CC.A5
R
1,280
GENERAL NOTES REFER TO GENERAL NOTES (A100).
3,062
548
91
CC.A6
CC.A7
450
130
CC.A3
200
345
CC.A1
CC.A2
300
WT 1
LEGEND R
MECHANICAL RISER
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS.
FW
FLOOR WASTE PENETRATION
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS
OT
OUTLET PENETRATION
50
50mm STEP DOWN
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
N
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
450
600
CC.A4
A
4,240
R
785
FW
600
4,330
OT
4,825
R 1,585
4,000
1,085
2,456
1,467
DG.12
435
8,000
8,000
DG.05
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SLAB SET DOWN & PENETRATIONS -GROUND FLOOR
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A201
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
5
FIRE RATEED GAS RISER
WT 4
FIRE RATED COMMS RISER
FIRE RATED MAINS RISER
2,050
SSL 8.5
1,800
300 1,200
470
1,195
50 OT
90 1,370 250 240 1,185
150
1,175 90
1,700
50
50
1,125
R
1,000 1,390
2,325
R 4,965
1,000
50
OT
OT
R 3,749 COL.B6
CC.B5
2,275 1,619
R
R 2,617
R 1,460
R
OT
1,240
1,485 450
50
3,900
100
520 1,310
2,190
249
1,485
R
SSL 8.5
R 2,598
100
1,077
90
2,835 2,925
1,488
3,265 OT
1,592
1,160
240
RAD. DIM GUIDE
4,200
1,600
REFER TO GENERAL NOTES (A100).
925
245 1,730
R 5,896
GENERAL NOTES
OT R
SSL 8.5
FW
R 5,559
OT
A
R 2,617
R 5,780
R
855
50
1,559
COL.B7
1,770
110
50 90
FW
50
OT
500
540
FW
2,150
2,800 2,270
R
WT 22,690
1,005
500
675 155 90 855 90
2,940
OT
OT
50
R
250
R
R
500
90240
1,870
50
2,515
FW
R
3,155
CC.B4
105
100
90 215 250 460 420
500
1,540
LIFT VOID
50
CHUTE PENETRATION
2,135
FW
COL.B7
500 715 500 2,625
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH FLOORS 2-5
1,315
740 COL.B7
1,660
1,315
R 4,965
COL.B7
150
600
COL.D7
150
SSL 8.5
COL.D6
2,610
FW
3,970 1,800
R
505
308
165
2,740
940
150
600
1,095
R
D1.02 D1.02 2,781
1,330 620 500 270
STAIR VOID
C
240 790
5,800
920 1,000
CC.D5
2,870
B
7
498
450
D
6
2,175
2,900
LEGEND R
MECHANICAL RISER
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS.
FW
FLOOR WASTE PENETRATION
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS
OT
OUTLET PENETRATION
50
50mm STEP DOWN
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
N
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
RAD. DIM GUIDE
4
RAD. DIM GUIDE
3
1,240
2
205 445
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SLAB SET DOWN & PENETRATIONS -FIRST FLOOR
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A202
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
5
FIRE RATEED GAS RISER
WT 4
FIRE RATED COMMS RISER
FIRE RATED MAINS RISER
2,050
SSL 8.5
300 1,200
1,800
470
1,195
50 OT
90 1,370 250 240 1,185
150
1,175 90
50
1,770
1,125
245
R 3,900
1,000 1,390
2,325
R 4,965
1,000
OT
1,240
R 2,617
R 3,749 COL.B6
2,275 1,619
520 1,310
2,190
249
R 5,559
3,265 OT
SSL 8.5
R 2,598
100
1,077
90
2,835 2,925
1,488
240
1,592
1,160
1,390
RAD. DIM GUIDE
2,760
1,485
R
1,600
REFER TO GENERAL NOTES (A100).
925
R 1,460
OT
OT
R
OT R
SSL 8.5
100
R 5,896
GENERAL NOTES
R 2,617
R 5,780
FW
CC.B5
4,200
OT
A
50
50 50
110
5,830
50
R
855
50
2,150
1,730
50
50
OT
500
540
FW
1,559
2,800 2,270
R
COL.B7
R
2,250
1,700
90
FW
1,005
500
WT 22,690
ATRIUM VOID
675 155 90 855 90
2,940
OT
OT
500
R
250
R
R
1,485 450
90240
1,870
50
2,515
FW
R
3,155
CC.B4
105
100
90 215 250 460 420
500
1,540
LIFT VOID
50
CHUTE PENETRATION
2,135
FW
COL.B7
500 715 500 2,625
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH FLOORS 2-5
1,315
740 COL.B7
1,660
1,315
R 4,965
COL.B7
150
600
COL.D7
150
SSL 8.5
COL.D6
2,610
FW
3,970 1,800
R
505
308
165
2,740
940
150
600
1,095
R
D1.02 D1.02 2,781
1,330 620 500 270
STAIR VOID
C
240 790
5,800
920 1,000
CC.D5
2,870
B
7
498
450
D
6
2,175
2,900
LEGEND
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS.
FW
MECHANICAL RISER FLOOR WASTE PENETRATION
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS
OT
OUTLET PENETRATION
R
50
50mm STEP DOWN
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
N
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
RAD. DIM GUIDE
4
RAD. DIM GUIDE
3
1,240
2
205 445
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
TYPICAL SLAB SET DOWN SECOND TO FIFTH FLOOR
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A203
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
8,000
8,000
6,700
18,720 840
18,865
FFL 4500
1
3 - RETAIL DESIGNATED
A1 A #LayID A305
G12
BICYC. STORE
PLANT ROOM
PC FFL 4.0
PC FFL 4.0
CC.B3
WT 1
1,100
2,400
470
FFL 4.5
RETAIL TENANT -NEWS AGENCY PC FFL 4.5
FW
G11
CC.B7
WT 2
FFL 4.0
DMT
TL FFL 4.5
FFL 4.5
UA RAMP 2
UP
501
502
503
401
402
403
303
1,200
DG.06
PC FFL 4.0
101
102
103
G02
DG.09
G06 WITH LOCKERS TL FFL 4.5
201
202
203
301
302 CC.A5
CC.A4 CC.A2
DG.07
RETAIL TENANT-CLOTHING BOUTIQUE PC FFL 4.5
G05
DG.10
CLEANERS ROOM PC FFL 4.5
DG.11
CC.A6
CC.A7
250
CC.A3 DP
WG.07
WG.08
WG.09
WG.06
DP
DP
WG.05
DP
WT 1
B A304
#LayID C
E 02 A06
1,200
1,700
1,200
1,700
1,200
1,740
800
2,670
1,200
250
18,355 32,485
116
50 70 130
40,000
GENERAL NOTE
LEGEND
REFER TO GENERAL NOTES (A100)
INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
DOOR MAT SIZE 1200X900mm
PLASTERBOARD 10mm STEEL STUD 92mm
CARPARK CONCRETE FLOOR FINISH TO BE FLOWCRETE DECKSHEILD ID LOW VOC POLYURETHANE COATING AND DEMARCATION SYSTEM; REFER TO MANUFACUTRER SPEC.
CC.D4 PC TL CPT TGSI D1.01 WG.01 WT 1 G 01 FW DP RCSS DMT MC
CONCRETE COLUMN D4 POLISHED CONCRETE TILE CARPET TACTILE GROUND SURAFCE INDICATOR DOOR -GROUND LEVEL -01, 02... WINDOW -GROUND FLOOR -01, 02... WALL TYPE 1, 2... GROUND FLOOR ROOM NUMBER 01, 02... FLOOR WASTE DOWN PIPE RESIDENTIAL CAR STACKER CAR SPACE DOOR MAT MOTOR CYCLE
RPB
RAISED PLANTER BED
TACTILE GROUND SURFACE GROUND INDICATORS TO BE DTAC STANLESS STEEL CLASSIC TGSI INSTALLED AT BOTTOM OF STAIR AND ON LANDING AT BEGGING OF FLIGHT AS PER AS 1428.1; SIZE 300XWIDTH OF RELEVANT STAIR
200
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS. WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
5,865
RIGID INSULATION & EXTERNAL CONCRETE LAYER
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
PRECAST AS PER ENG SPEC.NATURAL FINISH.
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS REFER TO DRAWING A520 FOR WET AREA PLANS & ELEVATIOINS
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
N
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
250
WT 3
CHANGE ROOM
RES STORAGE ROOM
MC
MC
WALL TYPE 3 CURTAIN WALL
250 E 01 A05
DG.32
DG.08
DG.12
2,985
1- RCSS
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
WG.03
CC.B6
F TOILET
G07
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
A1 A #LayID A305
DG.04
DG.05
TOTAL RES PARKING FOR 12 CARS
1,200
PIGMENTED CONCRETE LANDING
G04
DG.31
DG.14
DG.13
HERCULES SEMI-AUTO LIFT/SLIDE CAR 3 LEVEL STACKER
CC.A1
DG.03
WT 2
DG.30
WG.04
2- RCSS
A
DG.33
FW
CC.B4
DISABLED PARKING SHARED ZONE
2,500
3- RCSS
PC FFL 4.5
TL FFL 4.5
G09
CC.B5 CC.B2
RETAIL TENANT -HAIR SALON
12,469
G11
G03
DG.34
SHWR CURTAIN
3,967
2,400
DG.28
U/A RAMP 1
WG.02
TL FFL 4.5
5,325
20,790 6,035
4- RCSS
CC.B1
8,000
WT 4
M TOILET
CARPARK
CC.C7
UA
FW
G08 CONC FFL 4.0
CC.C7
FW
250
4,410
2,000 1,600
8,000
B
PC FFL 4.0
1 - RETAIL DESIGNATED
G11
LIFT
1,540
CC.C7
UP
WG.01
1,245
G10
2 - RETAIL DESIGNATED
BIN COLLECTION AREA
UP
WT 1
DG.29
CC.C5
DG.15
E 03 A07
POL. CONC FFL 4.5
A00 1
BIN ROOM EXIT
PC FFL 4.5
FFL 4.5
RES LETTERBOX INSTALLATION
CC.C3
CC.C2
G 00 RES ENTRY
FFL 4.0
UP
1,540
2
3
4
5
6
7
FFL 4.5
G01 RESIDENTIAL LOBBY
DG.02
3,927
5,400
DG.27
DG.01
4,825
CC.C1
326 3
25
24
23
22
21
20
19
18
17
16
13
UP
DG.26
FIRE ISOLATED EXIT
CARPARK ACCESS
FFL 4.0
DG.25
DMT
CC.D6
DG.19
3
8
2
9
11
DMT DG.17
10
UP 1
4,390
611 950
DG.24
3
DG.16
1,600
4,790
C
FIRST FLOOR OVER DASHED
DG.23 DMT
CC.D5
2
STRIP DRAIN WITH ALUMINIUNM GRATING CONNECTED TO LPOD
6,530
DG.22
DG.21
1
12
CONCRETE KERB RL 4.2
DG.20
DG.18
CC.D3
ENTER
LASER CUT ALUMINIUM SCREEN FIXED TO PRECAST CONCRETE WALL
3,896
B A304
CC.D2
A00 1
12,140
250
CC.D1
700
970
E 04 A08
WT 4
15
PLD 01 A401
14
#LayID C
BICYCLE ACCESS FROM LANEWAY TO CARPARK PEDESTRIAN FOOTPATH DG.35
D
700
1,220
200
700
940 494 750 700 840
250
3,446
5,415
1,250
2,470
250
LASER CUT ALUMINIUM SCREEN FIXED TO STEEL FRAME AROUND GF CARPARK
8,000
TITLE BOUNDARY
19,367
7
1,100
8,000
6
1
8,000
5
3
5,500
4
2
3
1
2
2
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
GROUND FLOOR PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A204
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
1
2
3
5,500
4
8,000
5
8,000
6
8,000
8,000
1,340
#LayID C
8,000 14,927
20
19
18
17
16
15
14
13
12
RISERS SERVICES
FIRE ISOLATED STAIR
10
WT 3
SERVICES CABINETS
CC.D5
COL.D6
FIRE HYDRANT
D1.02
1
2
3
4
5
6
7
8
9
20 x 170 = 3,400
1.01.1 BED 1
1.01.2 ENS
1.01.3 BED 2
1.01.4 LIVING
CPT
TL
CPT
WV
D1.05
D1.30
BIN ROOM POL. CONC.
COL.B7
DP
RPB
TL
D1.10
LIFT
D1.09
COL.B7
1.02.1 BATHROOM
DR
W
D1.12
WT 2
WV
CC.B4
D1.07 1.01.7 WC
TL
TL
WT 2
1.02.2 LAUNDRY
1.02.3 STORAGE
TL
TL
1.03.1 BATHROOM
WT 6
WV
P
W1.01
WV
APT 1.02
1.04 ATRIUM AND COMMUNAL AREA POL. CONC
D1.21
1.03.2 WC TL
1.02.10 BED 1
1.02.9 ENS
CPT
TL
1.02.8 ENS
1.02.7 BED 2
TL
CPT
COL.B6
CC.B5
W1.03
1.02.5 BALCONY
D1.14 D1.13
D1.16
FG
WT 6 DW
D1.15
BIR
TL
D1.22
COL.B7
1.01.6 KITCHEN & DINING
1.02.4 KITCHEN & DINING
FFL 8.5
APT FFL 8.5
1.03.9 LIVING
1.01.8 BATHROOM
D1.17
1.03
W1.04
800
W
D1.11
D1.29
A1 A #LayID A305
DR
COL.B7
TL
CPT
RPB
D1.08
1.01.9 LAUNDRY TL
WT 2
SUSTAINABLE FOOD GARDEN BEDS & RECYCLED 'PEZZI' TILE CONCRETE ROOF DECK WITH FALLS TO DRAINAGE OUTLETS SHOWN RL 8.5
A00 1 DW
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH FLOORS 2-5
1.03.10 BED 1
COMMUNAL TRAFFICABLE GREEN ROOF
RPB
APT 1.01 FFL 8.5
D1.18
W1.05
RPB
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
E 03 A07
D1.20
DP
OT
800
WT 3
FG
TL
1.02.6 LIVING
A1 A #LayID A305
FG
WV
E 01 A05
D1.23
DP DP
1.03.3 LAUNDRY
D1.28
W
1,500
1.01.5 BALCONY
TITLE BOUNDARY
1.05
FIRST FLOOR GREEN ROOF
1,090
L1 LOBBY SPACE CPT FFL 8.5
W1.06
RPB
D1.03
1.06
DMT
3,400
800 160 900
A00 1
1,200
13,240
D1.06
D1.01
OT
8,000
COL.D7
D 04
D1.04
B
2,853
A08
11
2,920 2,500
6,660
VOID FOR SERVICE E 04 RISERS
WT 4
D
4,790
8,000
5,310 B A304
6,900
C
7
FG
D1.24
TL
DANPALON CLEAR GLAZED PANELS FIXED TO
DR
4,590
WT 6
1.03.8 ENS
ALUMINUM FRAME AS CANOPY
WT 6
TL
1400X2300
1.03.4 KITCHEN & DINING
D1.27
8,000 8,000
FG
WV
OT W1.02
1.03.7 BED 1
FIRST FLOOR GREEN ROOF
DW
1.03.6 LIVING WV
1.03.5 BALCONY
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
TL
D1.26
CPT
1,100
WT 3 DP
A
3ยบ
3ยบ
3ยบ
DP
DP
3ยบ
DP
DP
LASER CUT ALUMINIUM SCREEN FIXED TO STEEL FRAME AROUND GF CARPARK
B A304
#LayID C
E 02 A06
8,000
2,935
5,065
5,658
2,342 285
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
116
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
50 70 130
13315
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT RIGID INSULATION & EXTERNAL CONCRETE LAYER INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
PLASTERBOARD 10mm STEEL STUD 92mm
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WALL TYPE 3 CURTAIN WALL
GENERAL NOTE
LEGEND
REFER TO GENERAL NOTES (A100)
CC.D4 PC TL CPT TGSI D1.01 WG.01 WT 1 G 01 FW DP RCSS DMT MC
CONCRETE COLUMN D4 POLISHED CONCRETE TILE CARPET TACTILE GROUND SURAFCE INDICATOR DOOR -GROUND LEVEL -01, 02... WINDOW -GROUND FLOOR -01, 02... WALL TYPE 1, 2... GROUND FLOOR ROOM NUMBER 01, 02... FLOOR WASTE DOWN PIPE RESIDENTIAL CAR STACKER CAR SPACE DOOR MAT MOTOR CYCLE
RPB
RAISED PLANTER BED
DOOR MAT SIZE 1200X900mm CARPARK CONCRETE FLOOR FINISH TO BE FLOWCRETE DECKSHEILD ID LOW VOC POLYURETHANE COATING AND DEMARCATION SYSTEM; REFER TO MANUFACUTRER SPEC. TACTILE GROUND SURFACE GROUND INDICATORS TO BE DTAC STANLESS STEEL CLASSIC TGSI INSTALLED AT BOTTOM OF STAIR AND ON LANDING AT BEGGING OF FLIGHT AS PER AS 1428.1; SIZE 300XWIDTH OF RELEVANT STAIR
200
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS. WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
150
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS REFER TO DRAWING A520 FOR WET AREA PLANS & ELEVATIOINS
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
50
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
PRECAST AS PER ENG SPEC.NATURAL FINISH.
KINGSPAN INSULATED WALL PANEL 0.5mm STEEL MICRO RIB EXTERNAL FINSIH
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
2,809 2,809
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
FIRST FLOOR PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A205
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
1
2 8,000
3 8,000
4
5
8,000
6
8,000
8,000
1,340 6,900
8,000
6,660
8,000
5,310
15,160
2,620
VOID FOR SERVICE RISERS
B A304
#LayID C
7
20
19
18
17
16
15
14
13
11
D
12
E 04 A08
RISERS SERVICES
SERVICES CABINETS
STAIR VOID
10
D 04
FIRE HYDRANT
1
2
3
4
5
6
7
8
D2.02
4,790
9
20 x 170 = 3,400
2.01.1 BED 1
2.01.2 ENS
CPT
TL
BIR
2.01.4 LIVING
CPT
WV
2.01.5 BALCONY
D1.05
D1.04
BIR
2.01.3 BED 2
TL
2.06
A00 1
C
2.05 13,240
BIN ROOM POL. CONC.
SELECTED FLOORING D1.10
D1.09
LIFT 2.02.1 BATHROOM
D2.20
2.02
8,000
E 03 A07
SUSTAINABLE FOOD GARDEN BEDS & TIMBER FLOOR DECKING RL 8.5
DR
W
DR
W
D1.11
2.01.8 BATHROOM
D1.07 2.01.7 WC
TL
TL
2.01.6 KITCHEN & DINING WV
P
D1.12
APT
2.03.10 BED 1
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
D1.08
2.01.9 LAUNDRY
TL
DP
COMMUNAL TRAFFICABLE GREEN ROOF
DW
TL
DP
FIRST FLOOR GREEN ROOF
A00 1
APT
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH
D1.30
2.01
D1.03
L1 LOBBY SPACE CPT
2.02.2 LAUNDRY
2.02.3 STORAGE
TL
TL
2.02.4 KITCHEN & DINING WV
FG
SELECTED FLOORING
CPT
DW BIR
D1.29 2.03.1 BATHROOM
2.03 A1 A #LayID A305
SELECTED FLOORING
WV
ATRIUM
2.02.10 BED 1
2.02.9 ENS
CPT
TL
BIR
D1.16
2.03.2 WC
D2.22
FG
TL
2.04
D2.21
2.02.5 BALCONY
D2.14
D2.15
BIR
TL
APT
2.03.9 LIVING
D2.17
2.02.8 ENS
2.02.7 BED 2
2.02.6 LIVING
TL
CPT
WV
A1 A #LayID A305
FG
TL
B E 01 A05
D1.28
2.03.3 LAUNDRY
W
DP
TL
DR
D2.23
DP
FG
2.03.8 ENS
FG
TL
2.03.4 KITCHEN & DINING
8,000
8,000
D1.27
WV
DW
2.03.6 LIVING 2.03.7 BED 1 CPT
FIRST FLOOR GREEN ROOF 2.03.5 BALCONY
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
TL
WV
BIR
DP
A
3ยบ
3ยบ
3ยบ
DP
DP
3ยบ
DP
DP
B A304
#LayID C
E 02 A06
8,000
2,935
5,065
8,000
250
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
116
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
50 70 130
13315
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT
GENERAL NOTE
LEGEND
RIGID INSULATION & EXTERNAL CONCRETE LAYER
REFER TO GENERAL NOTES (A100)
INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
DOOR MAT SIZE 1200X900mm
CC.D4 PC TL CPT TGSI D1.01 WG.01 WT 1 G 01 FW DP RCSS DMT MC
CONCRETE COLUMN D4 POLISHED CONCRETE TILE CARPET TACTILE GROUND SURAFCE INDICATOR DOOR -GROUND LEVEL -01, 02... WINDOW -GROUND FLOOR -01, 02... WALL TYPE 1, 2... GROUND FLOOR ROOM NUMBER 01, 02... FLOOR WASTE DOWN PIPE RESIDENTIAL CAR STACKER CAR SPACE DOOR MAT MOTOR CYCLE
RPB
RAISED PLANTER BED
PLASTERBOARD 10mm STEEL STUD 92mm
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WALL TYPE 3 CURTAIN WALL
CARPARK CONCRETE FLOOR FINISH TO BE FLOWCRETE DECKSHEILD ID LOW VOC POLYURETHANE COATING AND DEMARCATION SYSTEM; REFER TO MANUFACUTRER SPEC. TACTILE GROUND SURFACE GROUND INDICATORS TO BE DTAC STANLESS STEEL CLASSIC TGSI INSTALLED AT BOTTOM OF STAIR AND ON LANDING AT BEGGING OF FLIGHT AS PER AS 1428.1; SIZE 300XWIDTH OF RELEVANT STAIR
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
200
REFER TO SPECFICATION, RELEVANT MANUFACTUREERS SPEC AND SHOP DRAWINGS.
150
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
PRECAST AS PER ENG SPEC.NATURAL FINISH.
REEFR TO DRAWING A307 FOR STAIR CONSTRUCTION DETAILS REFER TO DRAWING A520 FOR WET AREA PLANS & ELEVATIOINS
2,845 2,845
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECOND TO FIFTH TYPICAL FLOOR PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A206
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
4
5 90
WT 4
DG.28
90
PLANT ROOM
PC FFL 4.0
PC FFL 4.0
1,917
CC.B3
90
DISABLED PARKING SHARED ZONE
G04
DG.31
RETAIL TENANT -NEWS AGENCY PC FFL 4.5
FW
G11
CC.B7
WG.03
CC.B6
TL FFL 4.5
DG.32
DG.08 501
502
503
401
402
403
303
1- RCSS
WITH LOCKERS TL FFL 4.5
PC FFL 4.0
MC
101
102
103
201
202
203
301
302 CC.A5
CC.A4 CC.A2
G02
DG.09 DG.07
CHANGE ROOM
RES STORAGE ROOM
MC
G06
RETAIL TENANT-CLOTHING BOUTIQUE PC FFL 4.5
G05
DG.10
CLEANERS ROOM PC FFL 4.5
DG.11
CC.A6
WG.06
DP
WG.05
DP
DP
2,620
950
6,700 7,465
116
50 70 130
6,617
INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
3,568 1,132
WT 1
350 2,620
200
WG.07
WG.08
WG.09
E 02 A06
RIGID INSULATION & EXTERNAL CONCRETE LAYER
CC.A7
CC.A3 DP
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT
800
DG.12
TOTAL RES PARKING FOR 12 CARS
DG.06
90
DG.05
HERCULES SEMI-AUTO LIFT/SLIDE CAR 3 LEVEL STACKER
CC.A1
WT 3
252
FFL 4.5
UA RAMP 2
UP
3,810
FFL 4.0
DMT
DG.13
2- RCSS
5,380
4,426 1,100 90 1,293 907 90
3,525 2,600
1,761
90
1,723
8,000
2,975
125 950 1,010 1,826 90 300 90 2,110
90
1,723
NOTES REFER TO GENERAL NOTES REFER TO PROJECT SPECIFICATION FOR WALL FINISHES SCHEDULE.
PLASTERBOARD 10mm STEEL STUD 92mm
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
200
WALL TYPE 3 CURTAIN WALL
PRECAST AS PER ENG SPEC.NATURAL FINISH.
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
N
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
90
E 01 A05
F TOILET
WT 2
DG.14
DG.04
1,827
1,650 4,253 200
PIGMENTED CONCRETE LANDING FFL 4.5
FW
CC.B4
WT 1
DG.03
WT 2
DG.30
WG.04
90
1,266 3,644 880 800 535 800 75
200
BICYC. STORE
CC.B5
3- RCSS
DG.33
TL FFL 4.5
G07
200
1,917 4,253
90
1,650
90
3 - RETAIL DESIGNATED
CC.B2
PC FFL 4.5
90
3,600
5,940
90 1,167
4- RCSS
RETAIL TENANT -HAIR SALON
M TOILET
CARPARK CONC FFL 4.0
G03
DG.34
SHWR CURTAIN
G11 G12
U/A RAMP 1
WG.02
TL FFL 4.5
DG.15
G09
4,107
UA
FW
G08
CC.C7
90
EXIT
CC.C7
FW
2,952
PC FFL 4.0
1 - RETAIL DESIGNATED
G11
LIFT
3,248
CC.C7
WG.01
3,860
G10
CC.C3
CC.C2
BIN ROOM
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
UP
WT 1
800
CC.C1
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
POL. CONC FFL 4.5
DG.29
CC.C5
DG.16
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
PC FFL 4.5
FFL 4.5
RES LETTERBOX INSTALLATION
CC.B1
A
G 00 RES ENTRY
FFL 4.0
UP
4,662
FFL 4500
FFL 4.5
G01 RESIDENTIAL LOBBY
DG.02
1,132
1
2
3
4
5
6
7
UP
DG.27
FIRE ISOLATED EXIT
CARPARK ACCESS
FFL 4.0
DG.26
DG.19
3
8
2
9
11
1
DMT DG.17
10
UP
DG.25
DMT DG.01
600
DG.24
CC.D6
4,958
3
25
24
23
22
21
20
19
18
16
15
14
13
DMT CC.D5
2 3
FIRST FLOOR OVER DASHED
DG.23
1
STRIP DRAIN WITH ALUMINIUNM GRATING CONNECTED TO LPOD
2,975
388 1,525 800 627
DG.22
DG.21
90 5,837
B
LASER CUT ALUMINIUM SCREEN
9,723 FIXED TO PRECAST CONCRETE WALL
DG.20
DG.18
CONCRETE KERB RL 4.2
BIN COLLECTION AREA
90
5,594
2 - RETAIL DESIGNATED E 03 A07
6,500
4,453
90 3,053 133
90
3,442
3,338
6,850 2,073
90 987
200
274 950 1,826
4,950
90
4,468
200
WT 4
12
C
90
4,553
E 04 A08
CC.D3
ENTER
950 145
8,426
90
1,997
3,954
CC.D2
90
236
BICYCLE ACCESS FROM LANEWAY TO CARPARK PEDESTRIAN FOOTPATH
1,572
3
CC.D1
5,365
90
7,697
DG.35
D
1,540
17
LASER CUT ALUMINIUM SCREEN FIXED TO STEEL FRAME AROUND GF CARPARK
2,620
90
9,830
5,380
1,398
7
1
6,121
6
2
3
1
2
2
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
PARTITION PLAN -GROUND FLOOR
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A207
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
2,870
5
366
6,264
230 2,087
4,030
90
800
6
340
2,953
345 905
1,794
3,970
90 700 87 1,348 90
2,180
1,340
880
3,057
90
20
19
18
17
16
15
14
13
12
10
SERVICES CABINETS
COL.D6
FIRE HYDRANT
1
2
3
4
5
6
7
8
9
4,293
1.01.1 BED 1
1.01.2 ENS
1.01.3 BED 2
1.01.4 LIVING
CPT
TL
CPT
WV
D1.05
D1.06
1.01.5 BALCONY TL
WV
APT 1.02
FG
WT 6
1.03 APT FFL 8.5
1.04
TL
ATRIUM AND COMMUNAL AREA POL. CONC
D1.21
1.03.2 WC
D1.22
TL
1.02.10 BED 1
1.02.9 ENS
CPT
TL
1.02.5 BALCONY
D1.14
D1.15
BIR
D1.13
D1.16
1.02.8 ENS
1.02.7 BED 2
TL
CPT
COL.B6
CC.B5
FG
TL
1.02.6 LIVING
WT 3
FG
WV
D1.23
DP DP
1.03.3 LAUNDRY
D1.28
FG
D1.24
TL
WT 6
240 90 90 1.03.4
1.03.8 ENS TL
D1.27
3,480
1685
W1.01
1.02.4 KITCHEN & DINING
1,200 90
TL
90
1.03.1 BATHROOM
90 663 950
1,709
TL
P
590
240 90 90
2,257
240 90 90
1.02.3 STORAGE
D1.17
W1.03
90
D1.12
1.02.2 LAUNDRY
WT 6
WV
3,265
90 855
WT 2
1.01.6 KITCHEN & DINING
FFL 8.5
D1.29
CC.B4
90
TL
3675
D1.11
WT 2
WV
TL
TL
CPT
1.03.9 LIVING
D1.07 1.01.7 WC
1.02.1 BATHROOM
WT 2
1.03.10 BED 1
W1.04
B
TL
1.01.8 BATHROOM
E 01 A05
950
SUSTAINABLE FOOD GARDEN BEDS & RECYCLED 'PEZZI' TILE CONCRETE ROOF DECK WITH FALLS TO DRAINAGE OUTLETS SHOWN RL 8.5
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH FLOORS 2-5
D1.08
1.01.9 LAUNDRY
500
E 03 A07
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
LIFT
D1.09
COL.B7
D1.18
W1.05
COMMUNAL TRAFFICABLE GREEN ROOF
D1.10
1,290 1,099
D1.20
DP
COL.B7 COL.B7
450
90
DP
APT 1.01 FFL 8.5
340
COL.B7
D1.03
240 90 90
2,073
D1.30
BIN ROOM POL. CONC.
FIRST FLOOR GREEN ROOF
240 90 90
L1 LOBBY SPACE CPT FFL 8.5
W1.06
5,837
D1.02
1.06
DMT
340 231 90 687 950 2,034
COL.D7
D1.01
1.05
2,806
6,970
D 04
D1.04
C
2425
1,915
WT 3
CC.D5
20 x 170 = 3,400
90
880
6,969
240 90 90
RISERS SERVICES
FIRE ISOLATED STAIR
880 90
90 90 240 1,500 2,800 90
A08
11
90 407
D
90
2,205
VOID FOR SERVICE E 04 RISERS
WT 4
2,969
7
450
4
2,850
3
2,741
2
375
1
WT 6
FG
KITCHEN & DINING WV
4,723
4,623
FIRST FLOOR GREEN ROOF
W1.02
1.03.7 BED 1
1.03.6 LIVING
1.03.5 BALCONY
WV
TL
D1.26
VEGETATED SPACE WITH INDIGENOUS PLANTING RL 8.5
CPT
WT 3
A
930
DP
221 2,870 465 880 2,174 LASER CUT ALUMINIUM SCREEN 90 90 FIXED 50 TO STEEL FRAME AROUND GF CARPARK 2,742 1450 1870
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
116
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
50 70 130
2,870
200 150
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
90 160 1,267 1,905 90
3220
1,927 1,370
700 1530
90 740 1990
325 2,400 715 1665
5,822
1,629 740 1,455 780 930
90 1,310 90 2,800 90
2,884
90
4900
6,601
NOTES REFER TO GENERAL NOTES REFER TO PROJECT SPECIFICATION FOR WALL FINISHES SCHEDULE.
PLASTERBOARD 10mm STEEL STUD 92mm
PRECAST AS PER ENG SPEC.NATURAL FINISH.
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
50
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
RIGID INSULATION & EXTERNAL CONCRETE LAYER
2890
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WALL TYPE 3 CURTAIN WALL
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT
199 1,251
E 02 A06
KINGSPAN INSULATED WALL PANEL 0.5mm STEEL MICRO RIB EXTERNAL FINSIH
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECOND TO FIFTH FLOORS TYPICAL PARTITION PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A208
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
3
4
5
6
7
B A304
2
E 04 A08
BICYCLE ACCESS FROM LANEWAY TO CARPARK PEDESTRIAN FOOTPATH
25
24
23
22
21
20
19
18
17
16
15
14
13
3
D
1
PLD 01 A401
2
#LayID C
1
1 2
STAIR VOID
1
G 00
3
1
2
3
4
5
6
7
G01
3
8
2
1
9
10
11
UP
2
UP
3
12
UP UP
A00 1
A00 1
C
G10 G02
G11
G11
E 03 A07
G08
A1 A #LayID A305
G09
G12
A1 A #LayID A305
G03
B G11
E 01 A05
UP
G04 G07
G06 G05
A
B A304
#LayID C
E 02 A06
GEN NOTES REFER TO SPECIFICATION FOR CEILING AND LIGHTING FIXTURES/FINISHES
ROOM
E 05 A502
G 01
RES LOBBY
G 02
RETAI L TENANT (SALON)
G 03
RETAIL TENANT (NEWAGENCY)
G 04
RETAIL TENANT (BOUTIQUE)
G 05
CLEANERS ROOM
G 06
CHANGE ROOM
AIR RETURN VENT LOCATION
G 07
RES STORAGE ROOM
SMOKE DETECTOR LOCATION
G 08
CARPARK
G 09
BICYCLE STORAGE
G 10
BIN ROOM
G11
PUBLIC TOILET
CEILING LED PANEL LIGHT 1200X300mm EXHAUST VENT HVAC DUCT LOCATION
FIRE ALARM UNIT RECESSED CEILING SPOT LIGHT WALL MOUNTED LED LIGHT
J03 A502
CEILING FINISH
CEILING HEIGHT
Flush Plasterboard
+3000
No Ceiling
+6000
Metal Mesh Ceiling Panels
+3000
No Ceiling
+6000
Metal Mesh Ceiling Panels
+3000
SERVICE CORRIDOR CEILING ALSO TO BE METAL MESH CEILING PANELS
+5000
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Client
NORTH
N
SUSPENDED LED PANEL LIGHT 1200X300mm
E 08 A502 J03 A502
ROOM LEGEND J01 A502
LEGEND
E 07 A502 J02 A502
E 06 A502
J02 A502
J01 A502
FOR HVAC, LIGHTING AND EXHAUST VENTS REFER TO SPECIFICATIONA DN MANUFACTURERS SOPECIFICATION
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
REFLECTED CEILING PLAN -GROUND FLOOR
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A209
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
4
5
6
1,580
1,630
3,420
1.01.3 BED
1,600
1,203
1.02.1 BATHROOM
810 500mm HIGH
B/H
1.03.08 STUDY
ATRIUM VOID
1.02.6 ENS
1.03.03 WC
1.02.5 BED
1,897 157
1.02.7 BED
1.04
APT
1.02.3 LIVING/ KIT 1.02.4 BED
A1 A #LayID A305
500mm HIGH
1,800
520
B
500mm HIGH
1.02.2 LAUNDRY
1.03.02 BATHROOM
1,000
A1 A #LayID A305
B/H
1,424
RPB
1.01.7 WC
1.02 APT 1.03
500
RPB
1.01.5 LAUNDRY
1.03.01 BED 1
2,050
E 03 A07
1.01.6 BATHROOM
596 676
LIFT VOID
STAINLESS STEEL FRAMED GLASS BALUSTRADE 1M HIGH FLOORS 2-5
500
2,900
1.05
1,050
RPB
A00 1
FCL +3.4M
OT
OT
1,002
1.01 APT
C
RPB
218
1.01.4 LIVING/ KIT
1.06
RPB
1,500
20
19
18
17
16
15
14
13
12
11
4,000
440 815
1.01.2 ENS
1.01.1 BED
1
2
3
4
5
6
7
8
1575
2,500
500mm HIGH
20 x 170 = 3,400 9
620
325
1,945
10
A00 1
960
4,000
E 04 A08
D
1,590
7
2,366
3
B A304
2
#LayID C
1
1.03.04 LAUNDRY
550 800 505
655
2,300 2,800
2,700 2,345
750 985
1,980 1,100
2,720 1,800
3,300
1,800
500mm HIGH
B/H
2,150
300
1,200
1.03.07 ENS
1,216
1,450
E 01 A05
1.03.06 BED
2,550
OT
500mm HIGH
A
#LayID C
6,750
750 500 740
1,160
B A304
E 02 A06 2,100
2,500
1,500
GEN NOTES REFER TO ROOM LEGEND FOR CEILING HEIGHT INFORMATION REFER TO SPECIFICATION FOR CEILING AND LIGHTING FIXTURES FOR HVAC, LIGHTING AND EXHAUST VENTS REFER TO SPECIFICATIONA DN MANUFACTURERS SOPECIFICATION
LEGEND
ROOM LEGEND SUSPENDED LED PANEL LIGHT 1200X300mm
J02 A502
AIR RETURN VENT LOCATION
05 WALL CAVITY AIR RETURNEVENT A502
CEILING HEIGHT
LOBBY
No Ceiling
+3400
Flush Plasterboard
+2700
Metal Mesh Ceiling Panels
+3000
APARTMENT 1
1.02
APARTMETN 2
1.03
APARTMENT 3
J03 A502
1.01
1.05 BIN ROOM
E 07
HVAC DUCT LOCATION A502 J01 A502
E 06 A502
CEILING FINISH
E 08 A502 J03 A502
EXHAUST VENT
J02 A502
J01 A502
CEILING LED PANEL LIGHT 1200X300mm
ROOM
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
SMOKE DETECTOR LOCATION
RECESSED CEILING SPOT LIGHT WALL MOUNTED LED LIGHT
GSEducationalVersion
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
N
FIRE ALARM UNIT
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECOND TO FIFTH FLOORS TYPICAL REFLECTED CEILING PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A210
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
A1 A #LayID A305
3ยบ
FG
CONCRETE ROOF 1:100 FALL TO PARAPET GUTTER FFL 25.5
12,793
PB
TSW
1,800
2,050 410 640 1,690
2100
4,530
ROOM 6.01 A211
ROOF TOP ACCESS ROOM FLOOR PLAN
FG PB
E 01 A05
FG
TSW
TSW
TSW
DP
DANPALON CLEAR GLAZED PANELS FIXED TO
8,000
COLOURBOND STEEL BOX GUTTER 600M WIDE 3O SLOPE TO SUMP
METAL SHADE SCREEN FIXED TO CURTAIN WALL -SHOWN DASHED
ยบ
3
ALUMINUM FRAME AS CANOPY FG
1400X2300
GF ROOF BELOW (SEE A205)
1,200
3ยบ
DP
A
B A304
#LayID C
E 02 A06
152 600
3,699
500 9,590
1,568 500
1,566
2,284 480
889
6,911
1,005
5,755
2,626
METAL SHADE SCREEN FIXED TO CURTAIN WALL -SHOWN DASHED
GENERAL NOTES
LEGEND
TSW: LYSAGHJT ZINCFORM TRAFFICABLE WALLKWAYS -REFER TO SPECIFICATION
DP RWH TSW PB
DOWN PIPE RAIN WATER HEAD TRAFFICABLE STEEL WALKWAYS PLANTER BOX SPLIT SYSTEM UNIT
RAH OT
ROOF ACCESS HATCH OUTLET
FLASHING TO BE CONSTRUCTED AT PARAPET, ALL ROOF JUNCTIONS AND PROJECTION -REFER TO SPECIFICATION SPLIT UNITS & HVAC SYSTEM TO BE INSTALLED AS PER MANUFACTURERES SPEC; AND HOUSED ON STEEL PLATFORMS EACH KARRA-260 60 CELL PV PANEL PRODUCE MAX 260KwP. ARRAY INSTALLED AS PER MANUFACTURERES SPEC WATER STORAGE TANK LOCATED -SEE A102. LOCATION AND CONSTRUCTION OF EXAHUST COWLS AND FLUES TO MECHANICAL & ELECTRICAL ENG. DETIALS
GORTER ROOF ACCESS HATCH TO BE INSTALLED AS PER MANUFACTURERS SPEC
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Client
NORTH
N
LOCATION OF ANCHORAGE POINTS AND ROOF PLATFORMS ACCORDING TO ENG. SPEC. ALL ROOF ANCHORS ARE TO BE COMPLIANT WITH AS/NZS 5532:2013; USE AND MAINTENANCE ARE TO COMPLY WITH AS 1891.4
2,150
1
2
2,635
21
20
19
2,820
5250
A1 A #LayID A305
DP 11,450
1,160 940
6,165
TSW
8,000
FG OT
3ยบ
40 TINDO KARRA-250 PHOTOVOLTAIC PANELS WITH TILT SUPPORTS ON STEEL PLATFORMS
WT 6
D6.03
TSW
TITLE BOUNDARY
TSW
TSW
E 03 A07
LIFT
PB
DP
18
CPT FFL 23.50
2,790
WT5 DP
GF ROOF BELOW (SEE A205)
1,555
2,100 2,690
1M HIGH BALUSTRADE TO INNER EDGE OF PLANTER BOX
LIFT OVER RUN
D6.02
ENCLOSED ROOFTOP ACCESS AREA
410
2,740
4,869
6.01
FFL 27.50 20 FALL
B
A00 1
OT
COLOURBOND KLIP LOK STEEL CLASSIC-700 ROOF SHEETING
D6.01
OT PB
3ยบ
21 x 181 = 3,800
2,439 2,105
4,790
TL ON PAVING SUPPORTS
A00 1
FIRE ISOLATED EXIT STAIR
11
10
1:100 FALL TO RAINWATER OUTLETS FFL 25.5
2,500
2,050
2,500
TRAFFICABLE CONCRETE ROOF RAH
C
12
PB
D
16
6,900
15
#LayID C
2,676
METAL SHADE SCREEN FIXED TO CURTAIN WALL -SHOWN DASHED
E 04 A08
ROOM 6.01 A211
503
3
5,250
17
9,374
4
2,602
8,000
B A304
6,900
8,000
5
8,000
7
6
8,000
6
14
8,000
5
7
5,500
4
13
3
8
2
9
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
ROOF PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A211
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
FCL 28.10
SUS. CEILING
D6.02
FFL 25.5 FCL 24.80
FFL 22.10
SUS. CEILING
FCL 21.4
FG
SL
FG
FG
FG
FCL 18.0
2,700
FG
FCL 14.6
FG
FG
FG
FCL 11.2
FG
FG
FG
FG
FG
FG
FG
SL
FG
W3.01
FG
FG
SL
FG
FG
D3.06
D3.13
FG
2,700
SL
FG
FG
FG
FLOORS 2-5 APARTMEN 1 GLASS BALCONY BALUSTRADES 1.5M HIGH
FG
SL
FG
FG
FG
W2.01
SL
FG
FG
D2.06
D2.13
D1.26
FFL 4.5
SL
2,700
FG
FG
FG
FG
D1.26
CURTAIN WALL SYSTEM; FIXED PANELS; REFER TO SHOP DRAWING COLOURBOND STEEL RWH AND DP; EVENING HAZE FINSH
FG
FLOOR 1 APARTMEN 1 BALCONY BALUSTRADES 1.5M HIGH ALUCOBOND DESSERT GOLD SPECTRA FINISH
FG
SL
FG
FG
FG
W1.01
SL
FG
D1.13
D1.24
FG
D1.06
FG
FG
FG
FG
FG
FG
FG
PT 1
PT 1
PT 1
PT 1
PT 1
PT 1
PT 1
ELMICH GREEN WALL SYSTEM FIXED TO PRECAST CONCRETE WALL
500sq CONCRETE COLUMN; CLAD IN ALUCOBOND DESSERT GOLD SPECTRA FINISH
WG.01
3,000
FCL 7.5
SL
D4.06
FG
SL
D3.26
FG
1,000
3,400 SUS. CEILING
4,000
FFL 8.5
FG
D4.13
FG
LEVEL 01
W4.01
FG
700
SUS. CEILING
FG
FULL HEIGHT WALL CLAD IN ALUCOBOND DESSERT GOLD SPECTRA FINISH
3,400 FFL 11.9
FG
SL
D4.26
AWS ALUMINIUM FRAMED SLIDING DOOR AND WINDOW; NATURAL FINISH
FG
LEVEL 02
FG
700
SUS. CEILING
FG D5.06
FG
SL
2,700
3,400 FFL 15.3
SL
D5.13
FG
LEVEL 03
FG
W5.01
700
SUS. CEILING
FG
AWS ALUMINIUM FRAMED SLIDING DOOR AND WINDOW; NATURAL FINISH
3,400 FFL 18.7
FG
D5.26
FG
LEVEL 04
FG
SL
700
LEVEL 05
FG
2,700
3,400
FG
GROUND FLOOR
D
700
ROOF
C
2,600
RL 28.5
SUS. CEILING
3,000
PARAPET
B
400
A
SL FG
FG
FG
FG
FG
FG
FG
PT 1
PT 1
PT 1
PT 1
PT 1
PT 1
PT 1
ES 1 RES ENTRY STAIRS TO CONCRETE LANDING
DG.02 3 2 1
3 2 1
ES 2 RETAIL ENTRY STAIRS TO CONCRETE LANDING
500
NGL 4.0
A
B
C
E 01 A03
D
ELEVATION 01 North View
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
ELEVATION 01
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A300
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
1
RL 28.5 FCL 28.10
5
6
7
D6.03
FCL 24.80
FCL 18.0
SUS. CEILING
FCL 14.6
SUS. CEILING
FCL 11.2
LEVEL 01
FFL 8.5
SUS. CEILING
FCL 7.5
700
ELMICH GREEN WALL SYSTEM FIXED TO KINGSPAN WALL ON STEEL CHANNELS
LASER CUT METAL MESH SCREEN FORMING CARPARK WALLS; LIGHT BRONZE METALLIC FINISH
700
FFL 11.9
1,000
3,400
LEVEL 02
LASER CUT METAL MESH SCREEN FIXED TO CURTAIN WALL; LIGHT BRONZE METALLIC FINISH
700
FFL 15.3
3,400
LEVEL 03
ELMICH GREEN WALL SYSTEM FIXED TO KINGSPAN WALL ON STEEL CHANNELS
COLOURBOND RWH AND DP; EVENING HAZE FINISH
7,700
SUS. CEILING
700
FFL 18.7
3,400
LEVEL 04
TYPICAL APARTMENT RENDERED CONCRETE BALUSTRADE;
CURTAIN WALL SYSTEM; CLEAR GLASS
2,700
FCL 21.4
2,700
SUS. CEILING
TYPICAL APARTMENT CURVED GLASS BALUSTRADE
2,700
FFL 22.10
3,400
LEVEL 05
2,700
700
FFL 25.5
3,400
SUS. CEILING
4
2,700
ROOF
3
ROOFTOP ROOM 6.01 RENDERED FINISH CONCRETE WALL
2,600
3,000
400
PARAPET SUS. CEILING
2
ELMICH GREEN WALL SYSTEM FIXED TO PRECAST CONCRETE WALL
5, 490
WG.09
WG.08
WG.07
WG.06
PRECAST CONCRETE PANEL RECKLI 'RIO BRAVO' FINISH
3,000
4,000
WG.05
ES 1 RES ENTRY STAIRS TO CONCRETE LANDING
GROUND FLOOR
FFL 4.5
ES 2 RETAIL ENTRY STAIRS TO CONCRETE LANDING 500
500
NGL 4.0
1
2
3
4
5
6
7
E 02 A03
ELEVATION 02 East View
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
ELEVATION 02
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A301
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
D
RL 28.5
SUS. CEILING
FCL 28.10
B
A
3,000
PARAPET
C
ROOF
FCL 24.80
FULL HEIGHT WALL CLAD IN ALUCOBOND DESSERT GOLD SPECTRA FINISH
3,400
SUS. CEILING
FFL 25.5
FFL 22.10
SUS. CEILING
FCL 21.4
3,400
LEVEL 05
FFL 18.7
SUS. CEILING
FCL 18.0
LEVEL 03
FFL 15.3
SUS. CEILING
FCL 14.6
AWS ALUMINIUM FRAMED AWNING WINDOW; NATURAL FINISH
PRECAST CONCRETE PANEL RECKLI 'RIO BRAVO' FINISH
3,400
3,400
LEVEL 04
AWS ALUMINIUM FRAMED AWNING WINDOW; NATURAL FINISH
FFL 11.9
SUS. CEILING
FCL 11.2
LEVEL 01
FFL 8.5
SUS. CEILING
FCL 7.5
GROUND FLOOR
FFL 4.5
4,000
3,400
LEVEL 02
PRECAST CONCRETE PANEL RECKLI 'RIO BRAVO' FINISH
PERFORATED METAL MESH SCREEN FORMING CARPARK WALLS; LIGHT BRONZE METALLIC FINISH
SECURE GROUND LEVEL ACCESS TO CARPARK; PORTION OF SCREENING MECHANICALLY OPENABLE -OUTLINE ONLY SHOWN FOR CLARITY
500
NGL 4.0
4,790
D
8,000
C
8,000
B
E 03 A03
A
ELEVATION 03 South View
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
ELEVATION 03
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A302
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
7
RL 28.5
SUS. CEILING
FCL 28.10
5
4
3
ROOF
LASER CUT METAL MESH SCREEN FIXED TO CURTAIN WALL; LIGHT BRONZE METALLIC FINISH
FCL 24.80
FFL 22.10
SUS. CEILING
FCL 21.4
CURTAIN WALL SYSTEM; CLEAR GLASS
3,400
LEVEL 05
1
COLOURBOND STEEL RWH & DP; EVENING HAZE FINISH
FFL 25.5
3,400
SUS. CEILING
2
ROOFTOP ROOM 6.01 RENDERED CONCRETE WALL; FINISH ?
3,000
PARAPET
6
FFL 18.7
SUS. CEILING
FCL 18.0
3,400
LEVEL 04
TYPICAL APARTMENT CURVED GLASS BALUSTRADE
FFL 15.3
SUS. CEILING
FCL 14.6
3,400
LEVEL 03
FFL 11.9
SUS. CEILING
FCL 11.2
TYPICAL APARTMENT RENDERED FINISH CONCRETE BALUSTRADE
ELMICH GREEN WALL SYSTEM FIXED TO KINGSPAN WALL ON STEEL CHANNELS
RECKLI PRECAST CONCRETE 'RIO BRAVO' FINISH
SECURE GROUND LEVEL ACCESS TO CARPARK FOR BICYCLE STORAGE FACILITY
3,400
LEVEL 02
ELMICH GREEN WALL SYSTEM FIXED TO PRECAST CONCRETE WALL & KINGSPAN METAL CLAD WALL
LEVEL 01
FFL 8.5
CURTAIN WALL SYSTEM; CLEAR GLASS
FCL 7.5
4,000
SUS. CEILING
LASER CUT METAL MESH SCREEN FORMING CARPARK WALLS; LIGHT BRONZE METALLIC FINISH
ELMICH GREEN WALL SYSTEM FIXED TO PRECAST CONCRETE WALL DG.23 DG.05
GROUND FLOOR
DG.22
DG.21
DG.20
DG.18 DG.35
FFL 4.5
500
NGL 4.0
7
6
5
4
3
2
E 04 A03
1
ELEVATION 04
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
GSEducationalVersion
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
West View
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
ELEVATION 04
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A303
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
A
B
C
D
COLOURBOND KLIP LOK STEEL CLASSIC-700 ROOF SHEETING
PARAPET
KINGSPAN AWP VERTICALLY LAID PANEL; WT6 REFER TO WALL TYPE SCHED. RL 28.5
GORTER ROOF ACCESS HATCH WITH SCISSORS STAIRS AS PART OF ASSEMBLY; POWDER COATED ALUMINIUM FINSIH
400
SUS. CEILING
2,600
6.01 ROOFTOP ROOM
FFL 25.5
700
ROOF
PHOTOVOLTAIC PANELS ON STEEL PLATFORMS
LASER CUT METAL MESH SCREEN FORMING CARPARK WALLS; LIGHT BRONZE METALLIC FINISH
CURTAIN WALL SYSTEM; CLEAR GLASS; REFER TO SHOP DRAWINGS
2,700
SUS. CEILING
APT 5.03 LIVING
D5.23
D5.22
5.06 LOBBY
D5.21
FG FG
FFL 22.10
APT4.03 LIVING
2,700
SUS. CEILING
D4.23
D4.22
4.06 LOBBY
D4.21
2,700
APT 3.03 LIVING
D3.23
D3.22
3.06 LOBBY
D3.21
2,700
RONDO SUSPENSION ROD BRACKETS FIXED TO CONCRETE AS PER MANUFACTURERS SPEC.
APT 2.03 LIVING
D2.23
D2.22
2.06 LOBBY
D2.21
700
FFL 11.9
LAUNDRY
BATHROOM
D1.23
D1.22
D1.21
1.06 LOBBY
FG
5,500
G07 RES STORAGE ROOM
COLOURBOND STEEL RWH AND DP; EVENING HAZE FINISH
G12 PLANT ROOM
SERVICE CORRIDOR
DG.12
D1.01
FG
7,700
1,000 3,000
APT 1.03 LIVING
SCD06 A401
FFL 8.5
SUS. CEILING
W2.06
WC
2,700
SUS. CEILING
GROUND FLOOR FIRE ISOLATED STAIR; WALL TYPE 4 REFER TO WALL TYPE SCHEDULE
FG FG
GROUND FLOOR
W3.06
700
FFL 15.3
SUS. CEILING
LEVEL 01
CONCRETE STAIR; ALUMINIUM HANDRAILS AND BALUSTRADES -REFER TO STAIR PLAN AND DETAILS
FG FG
LEVEL 02
W4.06
700
FFL 18.7
SUS. CEILING
LEVEL 03
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC AS INTERMEDIATED FLOOR SLABS
FG FG
LEVEL 04
W5.06
700
LEVEL 05
G01 RES GF LOBBY
DG.13
W1.06
CARPARK ACCESS
DG.17
FFL 4.5 GROUND SLABS AND FOOTINGS TO ENG. SPEC.
500
NGL 4.0
A
B
C
B A03
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
D
LATERAL SECTION BB
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECTION LATERAL
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A304
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
PARAPET
RL 28.5 FCL 28.10
3
4
2,600
SUS. CEILING
2
FFL 25.5 FCL 24.80
COLOURBOND STEEL RWH AND DP; EVENING HAZE FINISH STUDY/LOUNGE
BED 1
ENS
D5.17
SELECTED FINISH 3.2X1..6M
BED 2
D5.15
BED 2
D4.15
D5.14
BED 3
D4.14
BED 3
KITCHEN & DINING
BALCONY
KITCHEN & DINING
BALCONY
FCL 21.4
SUS. CEILING
FCL 18.0
RONDO SUSPENSION ROD BRACKETS FIXED TO CONCRETE AS PER MANUFACTURERS SPEC. KINGSPAN AWP VERTICALLY LAID PANEL; WT6 REFER TO WALL TYPE SCHED.
SUS. CEILING
FCL 14.6
FCL 11.2
LASER CUT METAL MESH SCREEN FORMING CARPARK WALLS; LIGHT BRONZE METALLIC FINISH
FCL 7.5
BATHROOM
BED 1
200mm REINFORCED CONCRETE SLAB 1:100 FALL TO DRAINAGE OUTLET TO ENG SPEC
STUDY/LOUNGE
BATHROOM
D3.17
SCD02 A400
BED 1
ENS SELECTED FINISH 3.2X1..6M
BED 2
D3.15
D3.14
KITCHEN & DINING
BED 3
BALCONY
ENS SELECTED FINISH 3.2X1..6M
D2.20
BED 2
KITCHEN & DINING
BED 3
D2.15
D2.17
BALCONY
NON-TRAFFICABLE GREEN TOOF ON 200mm REINFORCED CONCRETE SLAB DECK
SCD04 A400
D2.14 SCD03 A400
BATHROOM
R
D1.20
1.04
BED 1
D1.17
ENS SELECTED FINISH 3.2X1..6M
BED 2
D1.15
D1.14
KITCHEN & DINING
BED 3
BALCONY
SCD05 A401
ATRIUM
CARPARK
DG.35
G09
G12
BICYCLE STORAGE
PLANT ROOM
CORRIDOR
G11
FG
G04
FG
F TOILET DG.28
EXTERNAL RETAIL LANDING
CURTAIN WALL SYSTEM; CLEAR GLASS
RETAIL TENANT -NEWS AGENCY DG.29
ES 1 RES ENTRY STAIRS TO CONCRETE LANDING
FFL 4.5
ES 2 RETAIL ENTRY STAIRS TO CONCRETE LANDING
500
NGL 4.0
GROUND SLABS AND FOOTINGS TO ENG. SPEC.
1
2
3
4
5
6
7
A A03
LONGTITUDNIAL SECTION AA
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
GSEducationalVersion
ALUMINIUM FRAMED DANPALON MULTICELL 12mm THICK GLAZED PANEL FIXED TO PRECAST WALL AND CURTAIN WALL
G08
6,500
SUS. CEILING
D3.20
STUDY/LOUNGE
1,000
FFL 8.5
SELECTED FINISH 3.2X1..6M
REINFORCED CONCRETE BALCONY SLAB 150mm SET DOWN 100mm AS PER ENG. SPEC
3,000
LEVEL 01
ENS
D4.17
2,000
SUS. CEILING
STUDY/LOUNGE
SCD01 A400 700
FFL 11.9
BED 1
KINGSPAN AWP VERTICALLY LAID PANEL; WT6 REFER TO WALL TYPE SCHED.
2,700
LEVEL 02
BATHROOM
D4.20
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC
700
FFL 15.3
2,700
LEVEL 03
STUDY/LOUNGE
SINGLE PLASTERBOARD CEILING LINING 10mm FIXED TO FURRING CHANNEL; WITH SHADOWLINE TO WALL
2,700
FFL 18.7
700
FFL 22.10
LEVEL 04
GROUND FLOOR
BATHROOM
D5.20
2,700
SUS. CEILING
1M PARAPET TO BE KINGSPAN AWP VERTICALLY LAID PANEL; WT6 REFER TO WALL TYPE SCHED.
700
LEVEL 05
7
D6.03
2,700
SUS. CEILING
6
700
ROOF
5
400
1
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECTION LONGITUDINAL
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:100
Date:
Project No:
Drawing No.:
02COMS4
A305
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
PARAPET RL 28.5 GORTER ROOF ACCESS HATCH WITH SCISSORS STAIRS AS PART OF ASSEMBLY; POWDER COATED ALUMINIUM FINSIH
50
1,215
3,250
300 LINE OF LEVEL O1 LANDING OVER SHOWN DASHED
3,000
ST01
DG.07
TGSI
300
24
23
22
21
20
19
18
17
16
15
14
25
3
FFL 8500
930
930
ST02
1,090
TGSI
S A306
DG.30
1,000
FFL 4500
1
TGSI
3,400
50
1,215
2,750
300
300
950 TGSI
TGSI
50 D5.02
STD01 A306
500
50
+4,500 1 GROUND FLOOR
165
2
3
4
5
6
7
8
9
10
11
300
1,250 UP
930
S A306
70
ROOF FFL 25.5
1
12
170
2,030
50
2
1,000
D1.02
13
50
FFL 4000
STPL1 A204
970
50
S3 STPL2
FIRE STAIR PLAN GF
STAIR EXIT SECTION S3
LEVEL 05 FFL 22.10 300 300
2,100
950
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC WITH ABLEFLEX SEALED EXP. JOINT STEP FOOTING AS PER ENG SPEC.
1
2
3
4
5
6
7
8
D1.02
STEEL REINFORCING AND REBARS WITHIN CONCRETE STAIR
50
9
UP
150
50 950
LEVEL 04 FFL 18.7
FFL 8.5
10
975
50
50
D4.02
165
20
19
18
17
300
16
15
14
13
11
30mm GREY NON-SLIP NOSING STRIP TO BE APPLIED TO TREADS
950
12
2,500
50
3,400
1,300
2,100
RISER
3,825
3,400
CONCRETE STAIR; ALUMINIUM HANDRAILS AND BALUSTRADES -REFER TO STAIR PLAN AND DETAILS
50
700 50
675
2,250
300
5,650
940
STPL 03 A205
D3.02
310
FIRST FLOOR STAIR PLAN
LEVEL 03 FFL 15.3
300
900
50mm CHS STEEL HANDRAIL WITH RETURNS WELDED TO STEEL POSTS
300
STAIR BASE DETAIL 1:10
D2.02
STD02 A306
GROUND FLOOR FIRE ISOLATED STAIR; WALL TYPE 4 -REFER TO WALL TYPE SCHEDULE
LEVEL 02 FFL 11.9
CONTINUOUS 40mm CHS STAINLESS STEEL HANDRAIL 1M HIGH; FIXED TO WALL
TGSI
1,400
FFL 4,000
1,470
3
UP
50mm CHS STEEL POST BOLTED TO CONCRETE FLOOR. 20mm RAILINGGS WELDED TO CHS POST FRAME; SPACING TO BE MAX 100mm
S3 A306
FFL 4,500
300
300 TGSI
STPL2 A204
2
RISER: 165 GOING: 300 2R+G= 630 (MAX 700 MIN 500)
50
3,400
S3 A306
1
50
TGSI
STD01 A306
TGSI
TYPICAL STAIR PLAN ST02 150mm PAINTED STEEL BASE PLATE WITH 58mm OD TUBE SECURE TO CHS POST
GENERAL NOTES: 3,400
CONCRETE LANDING SLABS DOWL FIXED TO REINFORCED PRECAST CONCRETE WALLS WITH EPOXY SEALED JOINT D1.02
LEVEL 01 FFL 8.5
CONCRETE LANDING TOP AND BOTTOM REINFORCEMENT TO EXTEND/OVERLAP WITH STAIR REINFORCMENT 30mm GREY NON-SLIP NOSING STRIP TO BE APPLIED TO TREADS
STEEL REINFORCING AND REBARS WITHIN STAIRS
4,000
30mm GREY NON-SLIP NOSING STRIP TO BE APPLIED TO TREADS
GROUND FLOOR FFL 4.5 500
GROUND SLABS AND FOOTINGS TO ENG. SPEC.
STAIR EXIT SECTION SS
STD02 A306
CONTINUOUS 40mm CHS STAINLESS STEEL HANDRAIL 1M HIGH; WITH STEEL RAILS AS BALUSTRADE THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
S STPL1
STAIR TO LANDING DETAIL 1:10
Client
NORTH
Holmesglen City Institute
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
200mm REINFORCED CONCRETE BASE AS PER ENG. SPEC; WITH STEEL REINFORCEMENT MESH AND REBARS
TGSI: TACTILE GROUND SURFACE GROUND INDICATORS DTAC STANLESS STEEL CLASSIC TGSI INSTALLED AT BOTTOM OF STAIR AND ON LANDING AT BEGGING OF FLIGHT AS PER AS 1428.1 DG.19
NGL 4.0
STAIR CALCULATIONS IN ACCORDANCE WITH NCC AND RELEVANT AS. ST01 RISER: 160 GOING: 250 2R+G= 570 (MAX 700 MIN 500) STO2 RISER: 165 GOING: 300 2R+G= 630 (MAX 700 MIN 500)
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
STAIR PLAN
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:50, 1:10
Date:
Project No:
Drawing No.:
02COMS4
A306
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
COLOURBOND STEEL DP; EVENING HAZE FINISH
CONTINUOUS STEEL CHANNEL ANCHORED TO CONCRETE SLAB
KINGSPAN AWP VERTICALLY LAID PANEL; WT? REFER TO WALL TYPE SCHED. CUT END COVER FLASHING
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC
FIRE RATED CANISTER INSULATION APPLIED AS PANEL IS LAID 0.5mm COIL COATED DRIP FLASHING SEALED TO FACE OF PANEL WITH 6X4mm BUYTL SEALANT
SUSPENSION ROD BRACKET FIXED TO CONCRETE AS PER MANUFACTURERS SPEC. RONDO SUSPENDED CEILING KIT; 25mm TOP CROSS TAIL (0.55BMT), 28mm FURRING CHANNEL, 310mm SECTION JOINER, ALUMINIUM SHADOW LINE BEAD 10mm SECTION JOINER FIXED TO STEEL FRAMED WALL TO PROVIDE STABILITY SINGLE PLASTERBOARD CEILING LINING 10mm FIXED TO FURRING CHANNEL; WITH SHADOWLINE TO WALL
300X600mm PORCELAIN TILE NATURAL FINISHED & SEALED
REMOVABLE GALVINISED DUCTILE IRON FLAT GRATE WATER SEEPAGE FROM OUTLET PUDDLE FLANGE TO DISCHARGE THROUGH BUILT IN WEEPHOLES TO OUTLET
TILE ON PAVING SUPPORTS
PROSPECT PA 20+ POLYMIDE PAVING SUPPORTS; WITH LEVELING SHIMS
BITUMEN MEMBRANE TO EXTEND OUTLET PENETRATION
BITUMEN MEMBRANE TO EXTEND WALL EDGE
THERMAL INSULATION
THERMAL INSULATION
OUTLET EXTENSION
INSITU CONCRETE SCREED 50mm TO FALL TO DRAINAGE OUTLET; LIQUID WATERPROOFING MEMBRANE OVER SCREED 200mm REINFORCED CONCRETE SLAB TO FALL AS PER ENG. SPEC
100mm PVC OUTLET
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC
SCD02 A305 SCD01 A305
SLAB TO WALL CONNECTION DETAIL 1:10
TYPICAL ROOF OUTLET DETAIL
50mm DIA STAINLESS STEEL EXTRUDED HANDRAIL SILCONE FIXED TO GLASS 12mm TOUGHENED CLEAR GLASS AS PER ENG SPEC.
GENERAL NOTES
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
116
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
50 70 130
WALL TYPE SCHEDULE SCALE 1:50
DETAILS TO BE READ IN CONJUCTION WITH SECTIONS DRAWINGS, PROJECT SPECIFICATION AND STRUCTURAL ENGINEERS DRAWINGS AND SPECIFICATION
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT RIGID INSULATION & EXTERNAL CONCRETE LAYER INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
VERIFY ALL DIMENSIONS ON SITE PRODUCTS & MATERIALS SPECIFIED TO BE INSTALLED AND MAINTAINED AS PER THE MANUFACTURERS SPECIFICATIONS
ALUMINIUM TOP COVER (FLASHING) AND SEALANT TO WALL AND GLASS
PLASTERBOARD 10mm STEEL STUD 92mm
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WATERPROOFING MEMBRANE TO EXTEND TO TOP COVER (FLASHING) AND SEALANT
300X600mm PORCELAIN TILE NATURAL FINISHED & SEALED
PROSPECT PA 20+ POLYMIDE PAVING SUPPORTS; WITH LEVELING SHIMS
WALL TYPE 3 CURTAIN WALL
CONTINUOUS SILICONE BED TO 12mm GLASS AS PER MANUFACT. SPEC;
100mm STEEL GRATE DRAIN CLASP FIXED TO TILE EDGE
WATERPROOFING MEMBRANE APPLIED TO SCREED
INSITU CONCRETE SCREED 50mm
WATERPROOFING MEMBRANE TO BE APPPLIED TO BALCONY SLAB BEFORE SCREED POUR
300X600mm PORCELAIN TILE ON POLYMIDE PAVING SUPPORTS;
10mm ABLEFLEX JOINT AND MASTIC SEALANT
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
200
REINFORCED CONCRETE BALCONY SLAB 150mm 1:100 FALL TO GUTTER;
150
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
50
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
PRECAST AS PER ENG SPEC.NATURAL FINISH.
CAST INSITU CONCRETE WALL REINFORCED CONCRETE BALCONY SLAB 150mm; WITH APPLIED WATERPROOFING SHOWN DASHED
DRAINAGE OUTLET SHOWN DASHED CONNECTED TO DP
SCD03 A305
BALCONY SLAB DETAIL 1:10
SCD04 A305
BALCONY BALUSTRADE DETAIL 1:10
KINGSPAN INSULATED WALL PANEL 0.5mm STEEL MICRO RIB EXTERNAL FINSIH
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECTION DETAILS
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:10, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A400
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
THERMAL INSULATION
SS COLOURBOND PARAPET FLASHING CAPPING
LASER CUT ALUMINUM SCREENING PANELS
WATERPROOFING MEMBRANE
CURTAIN WALL SYSTEM- REFER TO MANUFACTURERS SHOP DRAWINGS
CAPPING FLASHING TO TOP OF PRECAST PANEL WITH TIMBER INFILL BLOCK
100X100 SHS BRACKET FIXED TO CURTAIN WALL MULLION; ALLOW FOR EXPANSION AT CONNECTION 100X50 RHS AS BASE FRAME FIXED TO ALUMINUM SCREEN; WELDED TO SHS; 200mm CLEARNACE TO SLAB
FLASHING OVER GUTTER EDGE 60X40mm DANPALON ALUMINIUM CONNECTOR FRAMING SECTION REFER TO MANUFACTURERS SPEC.
RL 8.50
APRON FLASHING TO WALL AND SLAB DANPALON 14mm ALUMINIUM FRAMING F SECTION AT 900mm C/C (PANEL WIDTH)
GREEN ROOF SYSTEM: ·GROWING MEDIA
INSITU CONCRETE SCREED; WATERPROOFING MEMBRANE OVER SCREED
LYSAGHT SPANDEK STEEL SUPPORT SHEET (TCT 0.42) WITH LYSAGHT ADJUSTABLE SUPPORT BRACKET FIXED TO CONC. BEAM AND WALL
·VEGETATION MAT
RL 8.50
·GEOTEXTILE FILTER LINING
SS COLOURBOND BOX GUTTER 300mm 100mm DEPTH
·DRAINAGE TRAY ·PROTECTION MAT (POLYETHELENE SHEET)
200mm REINFORCED CONCRETE SLAB AS PER ENG. SPEC 1:100 FALL TO GUTTER;
·THERMAL INSULATION ·LIQUID WATERPROOFING & ROOT RETARDANT
BITUMEN MEMBRANE TO EXTEND OVER SLAB EDGE; APPLIED OVER THERMAL INSULATION
SS COLOURBOND RWH & DP; EVENING HAZE FINISH CONTINUOUS STEEL ANGLE BRACKET FIXED TO DANPALON CONNECTOR FRAMING SECTION; BOLTED TO FERRULE IN PRECAST PANEL AS PER ENG SPEC
REINFORCED CONCRETE SLAB AS PER ENG. SPEC. WITH TYPICAL WATERPROOFING APPLIED
REINFORCED CONCRETE BEAM AS PER ENG. SPEC
DANPALON MULTICELL 12mm THICK GLAZED PANEL
STEEL DOWEL CONNECTION AS PER ENGINEER SPEC REINFORCED CONCRETE COLUMN EXTEND TO CONCRETE BEAM PRECAST CONCRETE PANEL
SCD05 A305
ENTRY CANOPY DETAIL 1:10
SCD06 A304
TYPICAL BOX GUTTER & FACADE DETAIL
LASER CUT ALUMINUM SCREENING PANELS FIXED TO 100X50mm RHS 100X100 SHS STEEL COLUMNS WELDED TO STELL BASE PLATE; BOLTED TO CONCRETE SLAB @ 1200mm C/C;
30mm CLEARANCE BETWEEN SHS AND CONCRETE COLUMN
RHS BRACKET FIXED TO SHS COLUNN @ 1200mm C/C
GENERAL NOTES
WALL TYPE 2 STEEL STUD WALL;PLASTER FINISH
116
WALL TYPE 1 PRECAST CONCRETE SANDWICH LOADBEARING PANEL
50 70 130
WALL TYPE SCHEDULE SCALE 1:50
200 150
WALL TYPE 5 REINFORCED IN-SITU CONCRETE
RIGID INSULATION & EXTERNAL CONCRETE LAYER INTERNAL & EXTERNAL NATURAL GREY OFF FORM FINISH
VERIFY ALL DIMENSIONS ON SITE PRODUCTS & MATERIALS SPECIFIED TO BE INSTALLED AND MAINTAINED AS PER THE MANUFACTURERS SPECIFICATIONS
PLD 01 A204
FACADE PLAN DETAIL 1:10
PLASTERBOARD 10mm STEEL STUD 92mm
PRECAST AS PER ENG SPEC.NATURAL FINISH.
CAST IN-SITU AS PER ENG SPEC.NATURAL FINISH.
PLASTERBOARD 10mm FIXED TO 92mm STEEL WALL FRAMING
50
WALL TYPE 6 KINSPAN INSULATED WALL PANEL; FIXED TO LIGHT STEEL FRAME WALL; PLASTERBOARD FINISH
LOADBEARING INTERNAL CONCRETE LAYER; WITH REINFORCEMENT
REINFORCED CONCRETE COLUMN D3 AS PER ENG. SPEC & AS 3600;
REFER TO MANUFACTURERS DRAWING & SPECIFICATIONS
WALL TYPE 3 CURTAIN WALL
WALL TYPE 4 REINFORCED PRECAST CONCRETE WALL
DETAILS TO BE READ IN CONJUCTION WITH SECTIONS DRAWINGS, PROJECT SPECIFICATION AND STRUCTURAL ENGINEERS DRAWINGS AND SPECIFICATION
KINGSPAN INSULATED WALL PANEL 0.5mm STEEL MICRO RIB EXTERNAL FINSIH
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
SECTION & PLAN DETAILS
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:10, 1:50
Date:
Project No:
Drawing No.:
02COMS4
A401
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
1,691
530 40 68 760
CL CL
82 1,252
100
141
924
372
79
SHD
WF 04
WF 03
WF 04
WF 04
WF 04
SHD
300
WC
BA
700
WC
BA
TYPICAL BATHROOM PLAN
IE05 A501
IE05.01 TYPICAL BATHROOM
100
B V
750 50
2,400
2,390
500
B
750 50 900 100
175
V
100
IEO5 A205
700
SF
440
800
D1.11
150
550 115
BA
600
FFL
TR
450
691
1,100
308
D1.11
TR
2,025 525
2,700
WC
CL
374
357
C
WF 03
780 1,425
SF
2,632
3
WF 03
1,095 600
WF 03
310
SK
CL
1,335
1 IE05 4 2 A501
IE05 A501
IE05 A501
IE05.02 TYPICAL BATHROOM
IE05.03 TYPICAL BATHROOM
IE05 A501
IE05.04 TYPICAL BATHROOM
2,115 1,011
IE06 2 A501
WF 03
WF 04
IE06.02 TYPICAL LAUNDRY
200 100 770 30
IE06 A501
IE06.04 TYPICAL LAUNDRY
WF 04
2,000
2,000
TYPICAL WC PLAN
465
260
FFL WC
WC
235
244
D1.07
445
404
2,700
2,440
689
WC CL
IEO7 A205
IE06.03 TYPICAL LAUNDRY
CP
1,915
IE07 2 A501
322
WM
WF 04
3
294
2,400
IE06 A501
WF 04
260
1
457
DR
CP
700
1,226
IE06 A501
IE06.01 TYPICAL LAUNDRY
LS
WM
149
D1.07
4
540 220 50
FFL
IE06 A501
620
160
419 830
TYPICAL LAUNDRYPLAN
92
2,400
CP
100
IEO6 A205
LS
90
415 600
D1.09
2,000
2,400
658
600
CL 681
WF 04
WF 04
BI
SK
58
W
WF 03
WF 04
WF 04
3
DR
WF 03 WF 03
60
1,915
4
WF 03
731
1,257
1
300
300
BIC
D1.09
1,000
110
780 30
253
300
620
500 26
121
IE07 A501
IE07.01 TYPICAL WC
IE07 A501
IE07 A501
IE07.02 TYPICAL WC
IE07 A501
IE07.03 TYPICAL WC
IE07.04 TYPICAL WC
NOTES REFER TO GENERAL NOTES REFER TO PROJECT SPECIFICATION FOR WALL FINISHES SCHEDULE.
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
TYPICAL APARTMENT WET AREAS
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:50
Date:
Project No:
Drawing No.:
02COMS4
A501
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
TYPIVAL PLASTERBOARD PAINT FINSIH WALLS FACINGOPEN KITCHEN 960
610
600
580
425
1,800 725
760 50 90
540
750
IE08.02 TYPICAL KITCHEN
CP CP
DW
DR
IE08 A502
IE08.03 TYPICAL KITCHEN
IE08 A502
IE08.04 TYPICAL KITCHEN
600
CAESAR STONE CAESAR STONE
J01 TYPICAL JOINERY ELEVATION
20 50 FFL
LAMINATE SILK FINISH LAMINATE SKIRTING
100
LAMINATE SKIRTING
LAMINATE SKIRTING
J02 TYPICAL JOINERY ELEVATION
J02 TYPICAL JOINERY ELEVATION
LAMINATE SILK FINISH
750
750
FFL
CAESAR STONE
920
50
LAMINATE SILK FINISH
550 75 60 70
LAMINATE SILK FINISH
100
100
CAESAR STONE
J03 TYPICAL JOINERY ELEVATION
J03 TYPICAL JOINERY ELEVATION
16MM HMR PARTICLE BOARD LAMINATE FINISH
50
CAESAR STONE
100
100
FFL
J01 TYPICAL JOINERY SECTION
16MM HMR PARTICLE BOARD LAMINATE FINISH
750
16MM HMR PARTICLE BOARD LAMINATE FINISH
J02 TYPICAL JOINERY SECTION
100
FFL
450
FFL
750
50
CAESAR STONE
450
465
610
J01 TYPICAL JOINERY ELEVATION
FFL
115 100
FFL LAMINATE SKIRTING
920
50
20 50
LAMINATE SILK FINISH
750
2,000 1,400
FFL 100
LAMINATE SKIRTING
LAMINATE SILK FINISH
100
FFL
BT
CP
IE08 A502
IE08.01 TYPICAL KITCHEN
LAMINATE SILK FINISH
860
LAMINATE SILK FINISH
BT
SK
90
IE08 A502
TYPICAL KITCHEN PLAN
LAMINATE SILK FINISH
CP
90
600
250 250 250 330 320 300
IEO8 A205
1,508
SK
755 55
FFL
DR
90
O
WF 05 P
85
WF 05
DR 292
WF 03
760 50
P
OHC
725 60
C L
FV
2,010
220 600
DW
2,700
380
3
RH 2,380
IE08 4 2 A502
BT
WF 03
OHC SK
1
WF 03
1,015
600
200
CT
WF 03
580 100
500
445
RH
P
600
1,180
600
55
300
135
65 760
790 1,800
2,690
650
900
3,175
J03 TYPICAL JOINERY SECTION
NOTES REFER TO GENERAL NOTES REFER TO PROJECT SPECIFICATION FOR WALL FINISHES SCHEDULE.
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
GSEducationalVersion
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
TYPICAL KITCHEN JOINERY
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:50
Date:
Project No:
Drawing No.:
02COMS4
A502
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
Window List
W1.03
W1.04
W1.05
W1.06
W2.01
W2.06
W3.01
W3.06
W4.01
W4.06
Type
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING Rw41
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Series 467 Architectural Awning Window Maximum Panel Dimensions 2022mm x 1400mm; Maximum Glass Thickness =24mm Frame Sashes fabricated for high wind load; Transoms located 500mm or greater above floor line. GLAZING 6.50mm VLam Hush glass; RATING37
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Series 467 Architectural Awning Window Maximum Panel Dimensions 2022mm x 1400mm; Maximum Glass Thickness =24mm Frame Sashes fabricated for high wind load; Transoms located 500mm or greater above floor line. GLAZING 6.50mm VLam Hush glass; RATING37
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Series 467 Architectural Awning Window Maximum Panel Dimensions 2022mm x 1400mm; Maximum Glass Thickness =24mm Frame Sashes fabricated for high wind load; Transoms located 500mm or greater above floor line. GLAZING 6.50mm VLam Hush glass; RATING37
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Series 467 Architectural Awning Window Maximum Panel Dimensions 2022mm x 1400mm; Maximum Glass Thickness =24mm Frame Sashes fabricated for high wind load; Transoms located 500mm or greater above floor line. GLAZING 6.50mm VLam Hush glass; RATING37
Finsih & Hardware
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with winders and side latches; Truth™ hardware resists wind load
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with winders and side latches; Truth™ hardware resists wind load
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with winders and side latches; Truth™ hardware resists wind load
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with winders and side latches; Truth™ hardware resists wind load
Height Width Window sill height
2,000 900 700
1,800 1,100 500
1,800 800 200
1,800 800 200
2,100 1,200 200
2,000 800 400
2,000 900 700
2,000 800 400
2,000 900 700
2,000 800 400
2,000 900 700
2,000 800 400
900
900 1,100
900
800 800
800
2,000
2,000
2,000
2,000
2,100
1,800
1,800
1,800
2,000
Elevation
2,000
W1.02
2,000
W1.01
2,000
ID
900
800
800
800
1,200
Window List
W5.01
W5.06
WG.01
WG.02
WG.03
WG.04
WG.05
WG.06
WG.07
WG.08
WG.09
Type
AWS Elevate™ Series 466 Architectural Awning Window Maximum Panel Dimensions 1800mm x 1200mm; Maximum Glass Thickness =24mm FRAME 102mm thick commercial grade aluminium GLAZING 8.5mm VLam Hush glass /10mm air gap / 6.50mm VLam Hush glass; RATING ion.
AWS Series 467 Architectural Awning Window Maximum Panel Dimensions 2022mm x 1400mm; Maximum Glass Thickness =24mm Frame Sashes fabricated for high wind load; Transoms located 500mm or greater above floor line. GLAZING 6.50mm VLam Hush glass; RATING37
AWS Series 607 FaceLINE™ framing system Shopfront framing 150mm x 50mm with the glazing pocket close to the front face Various Panel Dimensions; Maximum Glass Thickness 10.38mm GLAZING 6.38mm Laminated glass; RATING Rw32
AWS Series 607 FaceLINE™ framing system Shopfront framing 150mm x 50mm with the glazing pocket close to the front face Various Panel Dimensions; Maximum Glass Thickness 10.38mm GLAZING 6.38mm Laminated glass; RATING Rw32
AWS Series 607 FaceLINE™ framing system Shopfront framing 150mm x 50mm with the glazing pocket close to the front face Various Panel Dimensions; Maximum Glass Thickness 10.38mm GLAZING 6.38mm Laminated glass; RATING Rw32
AWS Series 607 FaceLINE™ framing system Shopfront framing 150mm x 50mm with the glazing pocket close to the front face Various Panel Dimensions; Maximum Glass Thickness 10.38mm GLAZING 6.38mm Laminated glass; RATING Rw32
AWS Series 525 LouvreMASTER™ Maximum Panel Dimensions 3014mm x 900mm; Maximum Glass Thickness = 6.38mm 131mm Overall frame with full height extruded aluminium 152mm blades (fixed position); 3° Fall in sill guides water, dust and salt out of the window.
AWS Series 525 LouvreMASTER™ Maximum Panel Dimensions 3014mm x 900mm; Maximum Glass Thickness = 6.38mm 131mm Overall frame with full height extruded aluminium 152mm blades (fixed position); 3° Fall in sill guides water, dust and salt out of the window.
AWS Series 525 LouvreMASTER™ Maximum Panel Dimensions 3014mm x 900mm; Maximum Glass Thickness = 6.38mm 131mm Overall frame with full height extruded aluminium 152mm blades (fixed position); 3° Fall in sill guides water, dust and salt out of the window.
AWS Series 525 LouvreMASTER™ Maximum Panel Dimensions 3014mm x 900mm; Maximum Glass Thickness = 6.38mm 131mm Overall frame with full height extruded aluminium 152mm blades (fixed position); 3° Fall in sill guides water, dust and salt out of the window.
AWS Series 525 LouvreMASTER™ Maximum Panel Dimensions 3014mm x 900mm; Maximum Glass Thickness = 6.38mm 131mm Overall frame with full height extruded aluminium 152mm blades (fixed position); 3° Fall in sill guides water, dust and salt out of the window.
Finsih & Hardware
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with cam handles, manual chain winders or concealed electric winders.
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze HARDWARE Awning sashes can be fitted with winders and side latches; Truth™ hardware resists wind load
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
Height Width Window sill height
2,000 900 700
2,000 800 400
2,700 1,200 200
2,700 1,200 200
2,700 1,200 200
2,700 1,200 200
600 1,200 3,000
600 800 3,000
600 1,200 3,000
600 1,200 3,000
600 1,200 3,000
600
ID
1,200
600
1,200
1,200
2,700
2,700
2,700
2,510
2,000
2,000
Elevation
2,700
800
600
600
600
40
1,200
800
150
900
1,200
1,200
1,200
1,200
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
WINDOW SCHEDULE
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:1
Date:
Project No:
Drawing No.:
02COMS4
A600
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 C:\Users\Charlottes_Web\Desktop\a19_S4_DES_02COMST4_16.3.23.pln
23/03/2016
Door Schedule ID Type
Finish
D1.01
AWS Series 51 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 900mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door stiles with 115mm midrail; removable snap-on 19mm high glazing beads on stiles with security glazing
D1.02
Access Industries Fire Doors Standard Panel Dimensions 2040 x 820; 2040 x 870; 2040 x 920; 2040 x 1020 FRAME two As per Manufacturer hour rated Frame throat is specfication. 145mm; Doors are 48mm HARDWARE Flush panic bolts; Mortise locks machined by manufacturer
R1
Width
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced 2,040 820 polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
D1.03
D1.03
Height
R1
Door Schedule ID Type
D1.07
R1
Finish
R1
Height
Width
2,440 700
Door Schedule ID Type
D1.14
2,100 900
D1.08
R1
R1
2,440 700
D1.15
2,400 950
D1.09
R1
R1
2,440 700
D1.16
2,100 900
D1.10
R1
R1
2,400 800
R1
R2
Finish
R1
Height
Width
2,400 700
Door Schedule ID Type
D1.22
R1
Finish
R1
Height
Width
2,400 700
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
D1.30
AWS Series 51 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 900mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door stiles with 115mm midrail; removable snap-on 19mm high glazing beads on stiles with security glazing
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced 2,040 820 polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
D2.17
2,400 700
D3.13
2,400 2,200
D3.23
2,400 900
AWS Series 51 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 900mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door stiles with 115mm midrail; removable snap-on 19mm high glazing beads on stiles with security glazing
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced 2,100 900 polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
D2.20
2,400 800
D3.14
2,400 700
D3.26
2,400 2,700
R
2,400 700
D1.23
R2
R2
2,400 900
D1.30
R2
2,100 800
D1.24
R1
R1
2,400 950
D2.02
2,100 900
D2.21
2,400 700
D3.15
2,400 700
D4.02
2,100 900
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,400 2,700 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
D2.06
2,400 2,700
D2.22
2,400 700
D3.17
2,400 700
D4.06
2,400 2,700
D1.17
R1
R1
2,400 700
D1.26
AWS Elevate™ Series 471 Apartment Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; fixed light highlights with run through jambs Panel configuration ‘x-f’. GLAZING 10.5mm Rw33
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced 2,012 894 polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
D1.27
R2
R2
2,100 900
D2.13
2,400 2,200
D2.23
2,400 900
D3.20
2,400 800
D4.13
2,400 2,200
D1.04
R1
R1
2,400 800
D1.11
R1
R1
2,400 700
D1.18
AWS Series 51 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 900mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door stiles with 115mm midrail; removable snap-on 19mm high glazing beads on stiles with security glazing
D1.05
R1
R1
2,400 800
D1.12
R2
R2
2,100 2,400
D1.20
R1
R1
2,400 800
D1.28
R1
R1
2,400 800
D2.14
2,400 700
D3.02
2,100 900
D3.21
2,400 700
D4.14
2,400 700
D1.06
AWS Elevate™ Series 471 Apartment Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; fixed light highlights with run through jambs Panel configuration ‘x-f’. GLAZING 10.5mm Rw33
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,400 2,700 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
D1.13
AWS Elevate™ Series 471 Apartment Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; fixed light highlights with run through jambs Panel configuration ‘x-f’. GLAZING 10.5mm Rw33
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,400 2,200 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
D1.21
R1
R1
2,400 700
D1.29
R1
R1
2,400 800
D2.15
2,400 700
D3.06
2,400 2,700
D3.22
2,400 700
D4.15
2,400 700
GENERAL NOTE DOOR ELEVATIONS HAVE NOT BEEN SHOWN FOR DRAWING CLARITY- REFER TO REFER TO MANUFACTURERS SPECFICATION & PRODUCT DETAILS REFER TO PROJECT SPECIFICATION FOR DOOR TYPE ('R1, C1..) SPECIFICATION
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
DOOR SCHEDULE 01
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:1
Date:
Project No:
Drawing No.:
02COMS4
A601
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016
Door Schedule ID Type
D4.17
D4.20
D4.21
D4.22
D4.23
D4.26
D5.02
Finish
Height
Width
2,400 700
2,400 800
2,400 700
2,400 700
2,400 900
2,400 2,700
2,100 900
Door Schedule ID Type
Finish
D5.06
D5.13
D5.14
D5.15
D5.17
D5.20
D5.21
Height
Width
2,400 2,700
2,400 2,200
2,400 700
2,400 700
2,400 700
2,400 800
2,400 700
Door Schedule ID Type
Finish
D5.22
Width
2,400 700
D5.23
2,400 900
D5.26
2,400 2,700
D6.02
2,100 1,500
D6.03
2,100 900
AWS Series 52 Commercial Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; GLAZING 10.5mm VLam Hush; RATING Rw33
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
Door Schedule ID Type
Finish
Height
Width
DG.02
AWS Series 52 Commercial Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; GLAZING 10.5mm VLam Hush; RATING Rw33
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,100 1,100 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
DG.09
C1
C1
2,400 800
DG.14
C1
C1
2,700 950
DG.21
C1
C1
2,100 700
DG.28
C1
C1
2,400 950
DG.03
AWS Series 50 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 1000mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door WRAP AROUND stiles with 115mm deep midrail; removable 19mm high glazing beads on stiles with security glazing
Cutsom door panel with fixed light glazing cut outs; (captive external glazing wedge) FINISH Qualicoatapproved powder Coat 2,100 1,500 (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
DG.10
C
C1
2,400 800
DG.15
C2
C2
2,400 1,500
DG.22
C1
C1
2,100 700
DG.29
C1
C1
2,400 950
DG.04
AWS Series 50 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 1000mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door WRAP AROUND stiles with 115mm deep midrail; removable 19mm high glazing beads on stiles with security glazing
Cutsom door panel with fixed light glazing cut outs; (captive external glazing wedge) FINISH Qualicoatapproved powder Coat 2,100 1,500 (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
DG.11
C1
C1
2,400 800
DG.16
C2
2,400 1,500
DG.23
C1
C1
2,100 700
DG.30
C1
C1
2,100 800
DG.05
AWS Series 50 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 1000mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door WRAP AROUND stiles with 115mm deep midrail; removable 19mm high glazing beads on stiles with security glazing
Cutsom door panel with fixed light glazing cut outs; (captive external glazing wedge) FINISH Qualicoatapproved powder Coat 2,100 1,500 (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
DG.24
C1
C1
2,100 700
DG.31
C1
2,100 800
C1
2,400 800
C1
2,400 800
C3
2,400 1,200
DG.06
C1
CC1
2,100 800
DG.12
2,700 950
DG.17
AWS Series 51 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 900mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door stiles with 115mm midrail; removable snap-on 19mm high glazing beads on stiles with security glazing
DG.18
Access Industries Fire Doors Standard Panel Dimensions 2040 x 820; 2040 x 870; 2040 x 920; 2040 x 1020 FRAME two AS PER MANUFACTURER hour rated Frame throat is 145mm; Doors are 48mm HARDWARE Flush panic bolts; Mortise locks machined by manufacturer
2,100 900
DG.25
C1
C1
2,100 700
DG.32
2,100 800
DG.26
C1
C1
2,100 700
DG.33
2,100 700
DG.27
C1
C1
2,100 700
DG.34
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced 2,788 950 polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
DG.12
AWS Series 50 Commercial Hinged Door Maximum Panel Dimensions 3000mm x 1000mm; Maximum Glass Thickness = 10.38mm FRAME 50mm Thick door WRAP AROUND stiles with 115mm deep midrail; removable 19mm high glazing beads on stiles with security glazing
Cutsom door panel with fixed light glazing cut outs; (captive external glazing wedge) FINISH Qualicoatapproved powder Coat 2,400 1,200 (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR Colourbond Evening Haze
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,400 1,100 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
DG.19
Access Industries Fire Doors Standard Panel Dimensions 2040 x 820; 2040 x 870; 2040 x 920; 2040 x 1020 FRAME two AS PER MANUFACTURER hour rated Frame throat is 145mm; Doors are 48mm HARDWARE Flush panic bolts; Mortise locks machined by manufacturer
C1
DG.20
C
2,100 800
DG.07
C1
C1
2,700 950
DG.13
AWS Series 52 Commercial Sliding Door Maximum Panel Dimensions 2700mm x 1500mm; Maximum Glass Thickness =20mm FRAME 101.60mm frame, with Subsills; GLAZING 10.5mm VLam Hush; RATING Rw33
FINISH Qualicoat-approved powder Coat (Duratec® thermosetting advanced polyester resin TGIC free powder coating); COLOUR 2,100 1,100 Colourbond Evening Haze HARDWARE Doors to be fitted with standard slimline ANDO surface mounted door lock
DG.08
C2
C2
2,150 1,100
DG.14
C1
D 04
DG.01
Height
2,100 900
C1
C1
C
GENERAL NOTE DOOR ELEVATIONS HAVE NOT BEEN SHOWN FOR DRAWING CLARITY- REFER TO REFER TO MANUFACTURERS SPECFICATION & PRODUCT DETAILS REFER TO PROJECT SPECIFICATION FOR DOOR TYPE ('R1, C1..) SPECIFICATION
THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND VERIFY ALL ERRORS AND REVISIONS OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DATE REV ISSUED BY THE DESIGNER FOR CONSTRUCTION.
Client
NORTH
Project Name
REV NOTES
GSEducationalVersion
N
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. STUDENT DECLARES THAT THIS ASSESMENT TASK IS THEIR OWN WORK UNLESS OTHERWISE ACKNOWLEDGED AND IS IN ACCORDANCE WITH THE INSTITUTE'S PLAGIARISM POLICY.
Holmesglen City Institute
23 MILL STREET EAST MELBOURNE VIC 3002 CMYDS@WEB.COM.AU 03-9887 3513
Drawing Title:
DOOR SCHEDULE 02
BUILDING 7, PLUMMER ST DEVELOPMENT
Scale @ A1
Status: CONSTRUCTION
Site Address:
1:1
Date:
Project No:
Drawing No.:
02COMS4
A602
320-332 PLUMMER St, PORT MELBOURNE DRAWN BY:
CHARLOTTE M 100502978 F:\Charlotte M 100502978\a19_S4_DES_02COMST4_16.3.23.pln
24/03/2016