Bms Century 1000

Page 1

Century 1000

Holter Analysis System Affordable and easy-to-use Holter analysis software designed by the company that's been scanning Holters for more than thirty years. Biomedical Systems has been providing Holter analysis services for more than 30 years. Having scanned more than 2 million Holter tests during that time, we've learned quite a bit about what makes a great Holter System. All of our knowledge and real-world experience have come together in the Century 1000 Holter analysis software, our solution designed for facilities with smaller Holter volumes.

The Century 1000 provides a suite of retrospective editing tools including page displays with color highlighting of abnormalities.

Comprehensive editing and validation tools After the system has analyzed the digital data, a number of tools are available to the analyst to quickly edit and print an accurate Holter report. Beat templates can be reviewed and edited using pointand-click commands. Validation mode provides a fast and easy method of viewing and documenting the most significant findings for each scan. The convenient page mode allows the operator to quickly view sections of the recording and verify the accuracy of the analysis via color-coding of detected abnormal beats. Analysis setup lets the user preview the normal template selected for arrhythmia analysis, and select a new normal if necessary.

Automated analysis with user input The Century 1000 system features automated arrhythmia analysis augmented with input from the user. Upon initiating a scan, the system prompts the operator to validate the normal template that the algorithm has chosen. The operator can accept the algorithm's choice, or choose another more appropriate normal template. The system then quickly processes the digital recording, comparing all beats with the normal template, and creating new template categories for each beat that differs from the normal waveform.

Validation provides rapid access to all examples of significant events for verification of analysis accuracy and documentation.

77 progress parkway st. louis, mo 63043 p: 1-800-877-6334 p: 1-314-576-6800 f: 1-314-576-1664 e: cardiology@biomedsys.com


Century 1000

Holter Analysis System Features and Specifications Analysis Tools and Capabilities

Software Features

• 2 channel arrhythmia analysis, either userselectable or automatic • 3 channel ST segment analysis • QT analysis on any single channel • Time-domain Heart Rate Variability • Supports sampling rates from 128 to 1024

• Automated arrhythmia analysis including retrospective editing tools • Page-mode display with color-coded beat highlighting • Template Editing with the ability to superimpose within any individual templates • RR Interval histograms and scatter plots • Validation Display for rapid identification of significant events • On-screen display of all analysis tables with editing capabilities • Point-and-Click Beat Editing

Holter Recorder Compatibility • Datrix VX3 Digital Holter recorders • Braemar DL and DXP series Digital Holter Recorders • ELA SpiderView™ Digital Holter Recorder • Cassette Recorders (system option) Final Report Options* • • • • • • • • • • • • • •

Cover Page (Paragraph or Tabular) General Table Supraventricular Ectopy Table Ventricular Ectopy Table Bradycardia Table Pacemaker Activity Table ST and Heart Rate Trend Ectopy Histograms Heart Rate Variability Strip List Summary Diagnostic Strips Patient Event Strips Significant Event Strips Full Disclosure

Template editing provides quick access to review, validate, or possibly edit QRS waveform classifications made by the system.

*Reports can be customized to include any or all of the sections listed above. The cover page can be customized with your logo and paragraph text that is specific to your facility or to individual referring physicians.

Century 1000 Configurations The system is available as software-only (includes flash card reader or recorder interface cable) or can be furnished as a complete solution including computer hardware and printer.

www.biomedsys.com

77 progress parkway st. louis, mo 63043 p: 1-800-877-6334 p: 1-314-576-6800 f: 1-314-576-1664 e: cardiology@biomedsys.com

CAR-013-507