THEATRE Concept ASSEMBLY AND CALIBRATION
www.cineversum.com
Ref: T9004000
Rev: 02
Part. No.: R599765
Changes CineVERSUM provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied warranties or merchantability and fitness for a particular purpose. CineVERSUM may make improvements and/or changes to the product(s) and/or the program(s) described in this publication at any time without notice. This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information in this publication; these changes are incorporated in new editions of this publication.
Copyright All right reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior written consent of CineVERSUM.
Guarantee CineVERSUM provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults. CineVERSUM must be informed immediately in writing of any complaints. If the purchaser or third party caries out modifications or repairs on goods delivered by CineVERSUM, or if the goods are handle incorrectly, in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear as well as normal maintenance are not subject to the guarantee provided by CineVERSUM either. The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer.
Trademarks Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders. All brands and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products of their manufactures.
2
R599765 - 2.35 THEATRE Concept
TABLE OF CONTENTS 1.0
2.35 THEATRE Concept .................................................................................................. 4 1.1 1.2 1.3
2.0
Projector-side configuration ............................................................................................ 9 2.1
2.2
2.3
3.0
The optional 2.35 THEATRE Concept (Ref.T9004000) ................................................................... 4 Installing the 2.35 THEATRE Slider ................................................................................................. 4 Anamorphic Lens alignment.............................................................................................................. 5 First install........................................................................................................................... 5 Adjust the 16:9 picture ........................................................................................................ 5 Set the horizontal position of the lens ................................................................................. 6 Set the tilt and vertical position of the lens ......................................................................... 7 Adjust the Anamorphic Lens Focus .................................................................................... 8 Configure the projector THEATRE Mode......................................................................................... 9 Plug the RF-Emitter to the Trigger 2 output of the projector.............................................. 9 Configure Initial Setup Menu -> Trigger 2 to THEATRE .............................................. 9 Select a wide format input: Aspect Ratio to Cinemascope .............................................. 9 Select a different input: Aspect Ratio to Full Screen ....................................................... 9 Using the Remote Control Unit. ...................................................................................................... 10 [ASPECT] button behavior ............................................................................................... 10 Quick Aspect Ratio changes on the same input ................................................................ 11 Using RS-232 protocole................................................................................................................... 11 Communication Specifications ......................................................................................... 11 Command Format.............................................................................................................. 11 Available Lengths and Commands.................................................................................... 12
Miscellaneous .................................................................................................................. 14 3.1 3.2
Dimensions ...................................................................................................................................... 14 Projection distances ......................................................................................................................... 14
R599765 - 2.35 THEATRE Concept
3
1.0 2.35 THEATRE CONCEPT
1.0 2.35 THEATRE CONCEPT 1.1
The optional 2.35 THEATRE Concept (Ref.T9004000) The Blackwing One centralizes the controls and automation commands of the 2.35 THEATRE Concept for a unique, versatile and unexpectedly simple to operate 2.35:1 theatre experience using the THEATRE Anamorphic Lens. The Blackwing One features the exclusive new version of the award-winning THEATRE Mode for a complete and incomparable control over a motorized anamorphic lens. The new THEATRE Mode features:
1.2
•
Integrated CIW system.
•
Dedicated menu to program the 12V Trigger2 output.
•
Direct access button on the Remote Control Unit to switch between Anamorphic and standard formats.
Installing the 2.35 THEATRE Slider a)Fix the Anamorphic lens to the 2.35 THEATRE Slider, double check the horizontal level of the Lens to avoid any picture trapezoidal distortion.
b) Use the 3x M6x15 screws to fix the 2.35 THEATRE Slider at the bottom of the projector.
M6x15 screews
4
R599765 - 2.35 THEATRE Concept
1.0 2.35 THEATRE CONCEPT
1.3
Anamorphic Lens alignment In order to install the 2.35 THEATRE Concept, you can operate the Anamorphic Lens position and setting up the lens alignment by using the RF-RCU to manually control its position. Plug the 2.35 THEATRE Concept to the main power.
First install The 2.35 THEATRE Concept comes with a Radio-Frequency remote control unit (RF-RCU) to operate the position of the Anamorphic Lens. •
Push Button 1 to move the Anamorphic Lens out
•
Push Button 2 to move the Anamorphic Lens in front of the projector beam. Button 1
Button 2
Use the RF-RCU supplied with the 2.35 THEATRE Concept during calibration only.
Adjust the 16:9 picture To obtain a good 2.35 picture, the 16:9 picture should be properly adjusted in the center of the screen fulfilling the available screen height. These adjustment are made by using the Zoom, the vertical shift and horizontal shift features of the projector. When the picture position is correct, adjust the picture focus.
ZOOM
ZOOM
Adjust the Zoom until the 16:9 picture fulfills the screen height.
R599765 - 2.35 THEATRE Concept
5
1.0 2.35 THEATRE CONCEPT
S
FOCU
Adjust the picture Focus
Set the horizontal position of the lens
Press button 2 of the RF-RCU to move the Anamorphic Lens in front of the projector beam to obtain a 2.35 projection.
6
R599765 - 2.35 THEATRE Concept
1.0 2.35 THEATRE CONCEPT
A
A
Adjust the Anamorphic Lens horizontal position to obtain a centered 2.35 picture. Tighten the 2 screws (A) when completed.
Set the tilt and vertical position of the lens
B B
Adjust the Anamorphic Lens tilt and vertical position, so that the projector light beam is centered into the
R599765 - 2.35 THEATRE Concept
7
1.0 2.35 THEATRE CONCEPT Anamorphic Lens. Tighten the 2 screws (B) when completed. You may obtain a residual pincushion effect at the screen when using a throw ratio between 1.5:1 and 1.8:1 or a projection distance shorter than 5 meters. It is recommanded to install your projector at a minimum distance of 5 meters from the screen and using 1.8:1 or higher throw ratio.
Adjust the Anamorphic Lens Focus
The Anamoprhic Lens features a 6-turns focus ring
y x
Not focused Focused The focus adjustment is requiered only on the horizontal x-axis. Turn the focus ring clockwise or anti-clockwise depending on the distance between the projector and the screen to obtain a clear picture. If the picture is not focused on the vertical y-axis, that means that the 16:9 picture, without the Anamorphic Lens, is not focused. Press button 1 on the 2.35 THEATRE Concept RCU to remove the lens and make the adjustments decribed in “Adjust the 16:9 picture�, page 5.
8
R599765 - 2.35 THEATRE Concept
2.0 PROJECTOR-SIDE CONFIGURATION
2.0 PROJECTOR-SIDE CONFIGURATION 2.1
Configure the projector THEATRE Mode Plug the RF-Emitter to the Trigger 2 output of the projector
12V Trigger 1 12V Trigger 2
RF-EMITTER
Connect the RF-Emitter provided with the 2.35 THEATRE Slider to the 12V Trigger 2 output
Configure Initial Setup Menu ⇒ Trigger 2 to “THEATRE” The “Initial Setup ⇒ Trigger 2” menu determines the Trigger 2 output located in the panel input of the Blackwing One this is a global parameter (for all inputs): •
ON: the 12V Trigger 2 is always active when the projector is switched ON.
•
OFF: the 12V Trigger 2 is always switched Off.
•
THEATRE: this option gives to the projector the full control of the Trigger 2 output levels to control the Anamorphic Lens position depending on the selected input and its aspect ratio.
Select a wide format input: Aspect Ratio to “Cinemascope” When selecting a wide format input (2.35:1, 2.37:1 or 2.40:1), the original aspect ratio of the source is larger than 16:9, you can see black bars on the top and the bottom of the screen. •
Select the Cinemascope aspect ratio for this input in the menu “Input Signal ⇒ Aspect Ratio ⇒ Cinemascope”.
Then choose the correct Cinemascope Aspect Ratio in the menu ”Input Signal ⇒ Cinemascope Aspect Ratio ⇒ 2.37” so that the black bars disappear and the active picture fulfills the height of the screen. The Anamorphic Lens is automatically placed in front of the projector to restore the correct picture aspect ratio.
•
Select a different input: Aspect Ratio to “Full Screen” When you switch to a different input, the Anamorphic Lens is automatically removed from the projector if the aspect ratio is not configured in Cinemascope. You can switch back to the previous input, the Anamorphic Lens will be automatically moved in front of the projector.
R599765 - 2.35 THEATRE Concept
9
2.0 PROJECTOR-SIDE CONFIGURATION
2.2
Using the Remote Control Unit.
Select active input
Select the correct Aspect Ratio
Blackwing One RCU and quick access to THEATRE Mode features
[ASPECT] button behavior The [ASPECT] button triggers the 5 aspect ratio modes. Once a given aspect ratios is selected, the order of the next aspect ratio is reversed so that the previous aspect ratio becomes the next aspect ratio as described below.
Full Screen
The 2.35 THEATRE Concept uses Full Screen and Cinemascope aspect ratios.
Cinemascope
Standard
Virtual Wide
Converted 16:9
When you press sequentially the [ASPECT] button, the aspect mode rotation goes clock-wise. Press [ESC] or wait 15 seconds until the message fades out to confirm selection. Next time that you will press the [ASPECT] button, the rotation order is reversed. This behavior ensures a fast switch between different aspect ratios.
10
R599765 - 2.35 THEATRE Concept
2.0 PROJECTOR-SIDE CONFIGURATION
Quick Aspect Ratio changes on the same input If Trigger 2 is set to THEATRE Mode, the 2.35 THEATRE Slider is automatically operated by selecting the “Cinemascope” aspect ratio by pressing sequentially the [ASPECT] button on the RCU. The projector will retain the aspect ratio setting for the selected input. To switch back to 16:9, choose the ”Full Screen“ aspect ratio. You can also use the Remote Control Unit by pressing twice the [ASPECT] button to switch forth and backward from Cinemascope to Fullscreen modes as described below: Full Screen on 2.35 screen
Full Screen
Cinemascope
16:9 format
2.35:1 format
When the source automatically switches format... ... press twice [ASPECT] button on the Remote Control Unit
2.3
Using RS-232 protocole Communication Specifications Control of 2.35 THEATRE Concept is possible using a computer or automation device connected with a RS-232 straight cable connected to the Blackwing One (male - female D-sub 9 pins cable). Communication specifications for this unit are as follows:
Baud Rate
115200 bps
Data Format
Binary
Character Length
8 bits
Parity
None
Stop Bit
1 bit
X on/off
None
Flow Control
None
Command Format When sending a command to this unit, use the following data format:
Header
Length
Command
EoD
1 or 3 bytes
0 or 1 byte
at least 1 byte
1 byte
Header
(00h) for power ON command, (77h 88h 99h) for other commands.
Length
The total bytes of “Length” and “Command”
Command
Designates the command
EoD
Designates the end of the data. Fixed to (FFh)
R599765 - 2.35 THEATRE Concept
11
2.0 PROJECTOR-SIDE CONFIGURATION
Available Lengths and Commands Command Header (00h) Power ON
Length
Command
None
01h
Length
Command
03h
02h 01hh
Switch Input
03h
Blanking
03h
Keypad
03h
12V Trigger #2
03h
Aspect Ratio
03h
Lens Aperture
03h
Picture Mode
03h
Picture Adjust
03h
02h 02h 02h 03h 02h 04h 02h 05h 02h 06h 02h 07h 02h 08h 02h 09h 01h 01h 01h 02h 01h 03h 01h 04h 01h 05h 01h 06h 01h 07h 01h 08h 01h 09h 03h 01h 03h 02h 03h 03h 03h 04h 03h 05h 03h 06h 03h 07h 03h 08h 03h 09h 03h 0Ah 04h 01h 04h 02h 04h 03h 04h 04h 04h 05h 04h 06h 05h 01h 05h 02h 05h 03h 05h 04h 05h 05h 05h 06h 05h 07h
Command Header (77h 88h 99h) Power OFF
12
Description If the projector is in standby mode, this command switch the unit ON. Description If the projector is powered ON, this command switch this unit into Standby Mode. (Directly OFF) Switch active input to Video (Composite) Switch active input to S-Video Switch active input to Component Switch active input to VGA (sD15) Switch active input to HDMI 1 Switch active input to HDMI 2 Toggle projector Blanking ON Toggle projector Blanking OFF MENU: Toggle OSD Menu ON and OFF UP: Uses as up function key for navigation DOWN: Uses as down function key for navigation LEFT: Uses as left function key for navigation RIGHT: Uses as right function key for navigation ENTER: Selects menu item or the next menu EXIT: exits the current menu to the previous one. SOURCE: Switch input source. Power OFF: Turn off the projector (send twice) Switch the trigger to ON. Switch the trigger to OFF Switch the trigger to THEATRE Switch aspect ratio to Standard Switch aspect ratio to Full Screen Switch aspect ratio to Cinemascope Switch aspect ratio to Converted 16:9 Switch aspect ratio to Virtual Wide Open one level up the Lens Aperture Close on level down the Lens Aperture Switch picture mode to Standard Switch picture mode to Dynamic Switch picture mode to Theater Switch picture mode to User 1 Switch picture mode to User 2 Switch picture mode to User 3 Show brightness slider (use left or right to modify) Show contrast slider Show colour slider Show hue slider Show sharpness slider Show black level slider Show white level slider
R599765 - 2.35 THEATRE Concept
2.0 PROJECTOR-SIDE CONFIGURATION Colour Temperature
03h
Gamma
03h
Scaling features
03h
Temporal Noise
03h
Mosquito Noise
03h
Block Artifact
03h
Reset to default
03h
06h 01h 06h 02h 06h 03h 06h 04h 06h 05h 06h 06h 06h 07h 07h 01h 07h 02h 07h 03h 07h 04h 07h 05h 07h 06h 07h 07h 08h 01h 08h 02h 08h 03h 08h 04h 08h 05h 08h 06h 08h 07h 08h 08h 09h 01h 09h 02h 09h 03h 09h 04h 09h 05h 09h 06h 0Ah 01h
Switch colour temperature to Low Switch colour temperature to medium Switch colour temperature to High Switch colour temperature to User 1 Switch colour temperature to User 2 Switch colour temperature to User 3 Switch colour temperature to Medium-high Switch gamma to Gamma 1 Switch gamma to Gamma 2 Switch gamma to Gamma 3 Switch gamma to Gamma 4 Switch gamma to User 1 Switch gamma to User 2 Switch gamma to User 3 Set detail enhancement to Off Set detail enhancement to Low Set detail enhancement to Medium Set detail enhancement to High Set TNR to Off Set TNR to Low Set TNR to Medium Set TNR to High Set MNR to Off Set MNR to Low Set MNR to Medium Set MNR to High Set BAR to Off Set BAR to On Reset settings to default value
Examples You want to... Switch the projector ON Switch the projector OFF Switch the projector OFF with OSD conďŹ rmation Change Active Input to Comp. Switch to 16:9 screen Switch to Cinemascope screen Display On Screen Menu Change aspect ratio to Cinemascope Change aspect ratio to Full Screen
R599765 - 2.35 THEATRE Concept
Command to send 00h 01h FFh 77h 88h 99h 03h 02h 01h FFh 77h 88h 99h 03h 01h 09h FFh 77h 88h 99h 03h 02h 04h FFh 77h 88h 99h 03h 03h 05h FFh 77h 88h 99h 03h 03h 06h FFh 77h 88h 99h 03h 01h 01h FFh 77h 88h 99h 03h 03h 06h FFh 77h 88h 99h 03h 03h 05h FFh
13
3.0 MISCELLANEOUS
3.0 MISCELLANEOUS 3.1
Dimensions
199 mm 7.8’’
691 mm
691 mm 27.2’’
27.2’’
3.2
14
530 mm
530 mm
20.9’’
20.9’’
Projection distances Projection Screen Size Diagonal size (Aspect Ratio 2.35:1)
Projection Screen Base size
Projection Screen Height
Blackwing One
107" (2720 mm)
98.4" (2500 mm)
41.7" (1060 mm)
3310 mm - 4780 mm
128" (3250 mm)
118.1" (3000 mm)
50.4" (1280 mm)
3960 mm - 5720 mm
149" (3780 mm)
137.8" (3500 mm)
58.7" (1490 mm)
4610 mm - 6650 mm
170" (4520 mm)
157.5" (4000 mm)
66.9" (1700 mm)
5260 mm - 7590 mm
200" (5080 mm)
184.3" (4680 mm)
77.5" (1970 mm)
6190 mm - 8930 mm
Projecting Distance minimum - maximum
R599765 - 2.35 THEATRE Concept
Contact Information: TEC - CineVERSUM 7, rue La CAILLE, 75017 Paris - FRANCE Web: www.cineversum.com
Contact information
TEC - CineVERSUM 7, rue La Caille, 75017 Paris, France www.cineversum.com Part. No. R599765