R
OSWORLD Experiment With The Truth
Autoclave Steam Sterilizer
R
OSWORLD Experiment With The Truth
CONTENTS Osworld Timeline
03
What Is An Autoclave?
04
Autoclave Sterilization Graph
05
Autoclave Steam Sterilizer
06
Osworld Portable Autoclave: Model No OAT-P
06
Osworld Standard Model Autoclave: Model OAT S Wingnut Type
06
Osworld Fully Automatic Or Gmp Model Autoclave – Model OAT E/S
07
Osworld Premium Model Autoclave – Single Handle – Internal/external Reservoir – Model OAT – SHI/SHE
08
Osworld Horizontal Autoclave – Model OAT – H
09
Osworld Range of Products
10
Clientele
11
R
OSWORLD OSWORLD TIMELINE …………………Character in Osworld is not automatic, it has been worked at. The benefit however is well worth the time and effort invested. 1972: Joseph D’Souza founded the business, and started by manufacturing and selling Oven, Incubator, Heating Mantle, Water Bath, and Hot Plate during the first years. The key factors behind company growth and continuance is his persistence and a strong sense of determination. As the organizations founder he values high morals and injected them strategically in to the ground work.
Experiment With The Truth
PROFILE At Osworld,
1988: Osbert D’Souza his son joins the business; the product range is further increased with additional products such as Autoclaves, Stability Chamber, BOD Incubator, Cooling Incubator and Vacuum Oven.
“Perseverance is the hard work we do after we get tired of doing the hard work we already did”
1990: Osworld executes its first export order of 50 Water baths and 30 Autoclaves. 1994: Oswin D’Souza his youngest son joins business. In the following year Osworld for the first time participates in a trade exhibition and displays its products at the Chemtech exhibition held at Nehru Centre, Mumbai. 1997: With the enforcement of GMP regulatory compliance in the pharmaceutical sector. Osworld takes proactive steps in implementing the guidelines to comply to the provisions of the new ruling 21 CFR Part 11 from the Food & Drug Administration (FDA). 2000: Company moves its registered office and assembly area to a new location in view of increased admin staff and marketing executives. 2003: A new manufacturing facility with increased production capabilities is built. The additional space with sophisticated machinery provides for increased production to cope with the sales demand. 2004: ISO 9000: 2000 quality assurance system is adopted, with Bureau Veritas, (formerly BVQI), worlds leading certifying body as the auditing agency. 2007: CE certification for Stability Chamber and BOD Incubator was effectively completed. This involves compliance to safety electrical requirements which were tested and assessed by a regulatory governing institute. 2008: The essential stringent compliance to the provisions of ruling 21 CFR Part 11 and its firm enforcement by the FDA led to Osworld outsourcing the development of new data storage software. Godrej & Boyce Mfg. Co. Ltd, one of India’s most trusted, reputed brands, having entered in to an agreement with Osworld, took over the task of developing the 21 CFR Part 11 software. A reliable well equipped software team at Godrej ensured the software was developed in a compliant way.
Recognition in the form of “Lifetime Achievement Award” received by Founder of Osworld group, Mr. Joseph D’Souza from his Excellency, Governor of Maharashtra at the Pharmaceutical Leadership Summit 2010 held on 26th June 2010 at Mumbai, India.
2010 Osworld filed its first Patent (Patent Pending Application No. 2075/MUM/2010) for Oslog Data Storage Device, a device used to interface varous Osworld equipments to a PC using Oslog 21 CFR Part 11 compliant software. Osworld also launched its Premium Model Autoclave Steam Sterilizer. ISO 9001:2000 certification was enhanced to ISO 9001:2008 certification.”
ISO 9001: 2008 Certified Organization
R
OSWORLD Experiment With The Truth
What is an Autoclave? An autoclave is a device to sterilize equipment and supplies by subjecting them to high pressure saturated steam at 121 째C or more, typically for 15-20 minutes. In its most basic form the autoclave is a pressure cooker. Water is heated in a pressurized environment to create steam. Using pressure makes it possible to heat to higher temperatures with less energy. Autoclaves are usually made of steel and have various configurations for removing air prior to pressurization. Downward displacement autoclaves use gravity to remove air. Steam pulsing autoclaves use pulses of steam along with pressurizing and depressurizing to reach optimum pressure. Vacuum pump autoclaves suck air out for pressurization. Superatmospheric autoclaves are a combination of steam pulsing and vacuum pump techniques. Autoclaves are widely used in microbiology, medicine, tattooing, body piercing, veterinary science, mycology, dentistry, chiropody and prosthetic fabrication. Typical loads include laboratory glassware, surgical instruments, medical waste, patient care utensils, animal cage bedding, and Lysogeny broth. A notable growing application of autoclaves is in the pre-disposal treatment and sterilization of waste material, such as pathogenic hospital waste. Machines in this category largely operate under the same principles as the original autoclave in that they are able to neutralize potentially infectious agents by utilizing pressurized steam and superheated water.
How Does an Autoclave Work? An autoclave sterilizes items by heating them with steam to a very high temperature. Some common temperatures at which autoclaves operate are: 115 degrees C/10 p.s.i., 121 degrees C/15 p.s.i., and 134 degrees C/30 p.s.i. (p.s.i.=pounds per square inch). The temperature, pressure and time of operation depend on the degree of sterilization needed.
What Does an Autoclave Kill? An autoclave using standard settings can kill most bacteria, spores, viruses and fungi (all models of Osworld Autoclaves). Most doctor's offices, tattoo parlors, dentist offices and other places where instruments might come in contact with contaminants have a small autoclave on site for disinfection (Osworld Portable Autoclave). Hospitals use larger autoclaves that look similar to industrial dishwashers to sterilize many items at once (Osworld Rectangular/Cylindrical Horizontal Autoclave). Heat kills microorganisms by causing vital proteins to coagulate. The proteins stick together causing fatal damage to the microorganism. An autoclave cooks microorganisms in the same way a pressure cooker cooks food, but at a higher temperature. Autoclaves use steam instead of dry heat because steam can more effectively transmit heat to the microorganisms.
Air Removal It is very important to ensure that all of the trapped air is removed, as hot air is very poor at achieving sterility. Steam at 134 째C can achieve in 3 minutes the same sterility that hot air at 160 째C takes two hours to achieve. Methods of achieving air removal include: Downward displacement (or gravity type) - As steam enters the chamber, it fills the upper areas as it is less dense than air. This compresses the air to the bottom, forcing it out through a drain. Often a temperature sensing device is placed in the drain. Only when air evacuation is complete should the discharge stop. Flow is usually controlled through the use of a steam trap or a solenoid valve, but bleed holes are sometimes used, often in conjunction with a solenoid valve. As the steam and air mix it is also possible to force out the mixture from locations in the chamber other than the bottom. Steam pulsing - Air dilution by using a series of steam pulses, in which the chamber is alternately pressurized and then depressurized to near atmospheric pressure. Vacuum pumps - Vacuum pumps to suck air or air/steam mixtures from the chamber.
R
OSWORLD Experiment With The Truth
• +ve Chamber Pressure (mbar)
Autoclave Sterilization Graph
• Chamber -ve Pressure (mbar)
x
Pre vac Drying Cycle
-ve Pressure Pulsing
+ve Pressure Pulsing
Sterilization
Exhaust
Post Drying Auto Exhaust Vac Cycle & cycle complete
End Cycle Buzer ON & Cooling Cycles ON
Autoclave Quality Assurance Sterilization bags/pads often have a "sterilization indicator mark" that typically darkens when the bag/pad has been processed. Comparing the mark on an unprocessed bag to a bag that has been properly cycled will show an obvious visual difference. There are physical, chemical, and biological indicators that can be used to ensure an autoclave reaches the correct temperature for the correct amount of time. Chemical indicators can be found on medical packaging and autoclave tape, and these change color once the correct conditions have been met. This color change indicates that the object inside the package, or under the tape, has been processed. Some computer-controlled autoclaves use an F0 (F-nought) value to control the sterilization cycle. F0 values are set as the number of minutes of equivalent sterilization at 121 °C (250 °F) at 15 psi (100 kPa) above atmospheric pressure for 15 minutes . Since exact temperature control is difficult, the temperature is monitored, and the sterilization time adjusted accordingly.
Types of Sterilizers a) Clinical Sterilizer: Designed to process medical devices or medicinal products. b) Laboratory Sterilizers: are designed to process laboratory goods and materials that are neither medical devices nor medicinal products and are not intended for use in the clinical care of patients.
Sterilants: Sterilizers can also be classified according to the sterilant used to effect sterilization. The commonly used sterilants are: a) high-temperature steam. b) dry heat (hot air). c) low-temperature steam and formaldehyde (LTSF). d) ethylene oxide (EO). The High-Temperature Steam is the sterilant of choice because of its superior sterilizing qualities. The various High Temperature Steam Sterilizers that Osworld manufactures is shown herein.
R
OSWORLD
Autoclave Steam Sterilizer
Experiment With The Truth
Osworld offers various types of Autoclaves (High Temperature Steam Sterilizers):
Vertical Top Loading Autoclaves • • • • •
Portable Autoclave – small desktop autoclave Standard model Autoclave – Wingnut type Fully Automatic Autoclave – Wingnut type (available only in GMP Model) Premium Model – Single Handle Autoclave with Internal Reservoir (Available in Standard as well as GMP model) Premium Model – Single Handle Autoclave with External Reservoir (Available in Standard as well as GMP model)
Horizontal Front Loading Autoclaves • Horizontal Autoclave – Cylindrical or Rectangular Autoclaves (Available in Standard as well as GMP model)
Vertical Top Loading Autoclaves Osworld Portable Autoclave: Model No OAT-P • Desktop Autoclave, available in small capacities of 21 litres. • Single Drum with heater and stand inside. • Entirely made of Stainless Steel 304 grade, mirror finish. • Standard size available: 300mm dia x 300 mm height.
Osworld Standard Model Autoclave: Model OAT S Wingnut Type Application: For use in Microbiology, QC & Research laboratories - Pharma Industry. • Vertical type, Double wall design has single chamber for steam and water. • Inner chamber/Outer cover made of SS 304 grade. • Lid, flange & bottom sheet also made of stainless steel. All joints argon welded. • Pressure range: 15 PSI. Temperature Range: 121°C to 125°C. • Lid fitted pressure gauge, safety spring loaded pressure valve, and steam release valve. • Electrical: 230V / 15A / 50 Hz. • Temperature Control: controls pressure and temperature with digital temperature indication, factory set at 121°C (15 PSI), along with built in adjustable digital timer for maintaining sterilization cycle time with auto cut off. Size of Useable Chamber
Overall Dimension
Capacity
Rating
Foot Lifting Arrangement
Standard Model
in cms Dia x Ht 30 x 50 35 x 55 45 x 60 45 x 75 55 x 75
in cms LxWxH 45 x 66 x 106 51 x 71 x 117 72 x 78 x 122 72 x 78 x 137 82 x 92 x 135
Litres
KW
To Lift Lid
Model No
35 52 95 125 175
2.0 3.0 4.0 4.0 3.0x2
No No Yes Yes Yes
OAT S – 35 OAT S – 52 OAT S – 95 OAT S – 125 OAT S – 175
Optional Accessories offered by Standard model: Basket, Printer Interface, High Temp Safety Controller
R
OSWORLD Experiment With The Truth
Vertical Top Loading Autoclaves
Osworld Fully Automatic or GMP Model Autoclave – Model OAT E/S Application: For use in Microbiology, QC & Research laboratory – Pharma Industry.? • Double wall design has single chamber for steam and water. • Fully Automatic operation; cycle begins by press of the START button. • Initial air purging cycle; at the beginning air is automatically removed from the chamber. • Microprocessor based Digital Temperature Indicator Controller. Controls temperature / pressure precisely at set value. • In built adjusted digital timer; programmable as per sterilization load requirement. • Automatic steam exhaust at the end of cycle. • Electrical Low water level heater safeguard. • All parts of stainless steel 304 grade. All joints argon welded. • Jointless silicon gasket. Heavy duty industrial flange heater. • Pressure range: 15 PSI. Temperature Range: 121°C to 125°C. • Lid fitting pressure gauge, safety spring loaded pressure valve, steam release valve. • Hydraulically tested at 60PSI. • Foot lifting arrangement included for capacity 95ltrs and above. • Electrical: 230V / 15A / 50 Hz. • Calibration certificate by ERTL – Mumbai with traceability to NPL – New Delhi. Provided with DQ, IQ, OQ, documentation.
Size of Useable Chamber
Overall Dimension
Capacity
Rating
Foot Lifting Arrangement
GMP
in cms Dia x Ht 30 x 50 35 x 55 45 x 60 45 x 75 55 x 75
in cms LxWxH 45 x 64 x 92 51 x 69 x 102 62 x 73 x 110 62 x 73 x 125 82 x 92 x 125
Litres
KW
To Lift Lid
Model No
35 52 95 125 175
2.0 3.0 4.0 4.0 3.0x2
No No Yes Yes Yes
OAT G - 35 OAT G - 52 OAT G - 95 OAT G – 125 OAT G – 175
Optional Accessories offered by Fully Automatic model: Basket Printer Interface (1 Temp + 1 Pressure printing or 3 Temp + 1 Pressure Printing) High Temp Safety Controller
Printer Interface
PC Software
Fo printing PC software 21CFR Part 11 compliant
PLC Based System
Basket
R
OSWORLD Experiment With The Truth
Vertical Top Loading Autoclaves
Osworld Premium Model Autoclave – Single Handle – Internal / External Reservoir – Model OAT – SHI / SHE Application: For use in Microbiology, QC & Research laboratory – Pharma Industry • Double wall type design however has inner chamber for steam, outer as cover. • Choose from 2 models Internal Reservoir or External Reservoir. • Fully Automatic operation; cycle begins by press of the START button. • Initial air purging cycle; at the beginning air is automatically removed from the chamber. • Microprocessor based Digital Temperature Indicator Controller Controls temperature / pressure precisely at set value. • Temperature Sensor: PT – 100. • In built digital timer; timer can be adjusted as per sterilization load requirement, 1 to 99minutes. • Automatic steam exhaust at the end of cycle. • Low water level heater safeguard. • Safety high pressure release valve. • Safety high temperature cut off. • Working chamber made of stainless steel LM 304 grade. • Outer cover made of Mild Steel for Standard model duly powder coated and stainless steel 1mm thick for GMP model, however, inner frame structure of solid chrome plated finish. • Lid, flange & bottom sheet also made of stainless steel SS 304. All joints argon welded. • Silicon gasket. Heavy duty industrial flange heater. • Pressure range: 15 to 30 PSI, factory set at 15 PSI, 15 minutes ster. Cycle time. • Temperature Range: 121°C to 134°C. • Temperature Resolution: 0.1°C / Temperature Accuracy: ±0.5°C. • Pressure gauge 0-50 PSI, safety spring loaded pressure valve, steam release valve. • Hydraulically tested at 75PSI. • Additional Safety: i) Pressure Switch made in Europe, CE certified for additional safety. Factory set at 30PSI. ii) Vacuum breaker cum lid locking arrangement for locking lid above 80degC. iii) Multiple micro-switches to sense lid closure, lid proper latching such that heating won't start if parameters not satisfied. • Electrical: 230V / 15A / 50 Hz. • Calibration certificate by ERTL – Mumbai with traceability to NPL – New Delhi. • Provided with DQ, IQ, OQ, documentation. Size of Useable Chamber
Overall Dimension
Capacity
Rating
Model No For Standard Model
Model No For GMP Model
in cms Dia x Ht
in cms LxWxH
Litres
KW
Outer Mild Steel and Inner S.S.
Complete Unit of SS 304 Grade
35 x 55 35 x 66 35 x 75 45 x 60 45 x 75 55 x 75
45 x 64 x 92 51 x 69 x 102 62 x 73 x 110 62 x 73 x 115 62 x 73 x 125 82 x 92 x 125
52 65 75 95 125 175
3.0 3.0 4.0 4.0 4.0 3.0x2
OAT – SHI/E*-S 52 OAT – SHI/E*-S 65 OAT – SHI/E*-S 75 OAT – SHI/E*-S 95 OAT – SHI/E*-S 125 OAT – SHI/E*-S 175
OAT – SHI/E*-/G 52 OAT – SHI/E*-/G 65 OAT – SHI/E*-/G 75 OAT – SHI/E*-/G 95 OAT – SHI/E*-/G 125 OAT – SHI/E*-/G 175
* I/E for Internal or External Reservoir model
Optional Accessories offered by Premium Model: • Basket • Printer Interface (1 Temp + 1 Pressure printing or 3 Temp + 1 Pressure Printing). • High Temp Safety Controller. • Fo printing. • PC software 21CFR Part 11 compliant. • Electrical actuator to ensure lid doesn't open under pressure. • Electromagnetic door lock for locking lid under pressure. Imported from Europe, patented design, CE marked. Can keep door locked upto 300 Newton pressure. • PLC based system with 5.7” HMI Touch Screen display: - Pressure Pulsing: both +ve and –ve pressure pulsing is programmable. - Assisted Air Cooling: for quick cooling of chamber. - Vacuum Pump system for automatic pre/post vacuuming with pulsing. - Drying cycle. - Automatic Water Fill – automatic water filling in reservoir.
R
OSWORLD Osworld Horizontal Autoclave
Experiment With The Truth
Osworld Horizontal Autoclave – Front Loading– Cylindrical / Rectangular Model Model OAT-H Opening: Front opening Working pressure: 1.2 to 1.7 kgf / cm2g Working temperature: 121°C to 134°C Material of Construction: Inner and outer Inner working chamber: Stainless steel 316 grade of 6mm thickness Chamber flange: Stainless steel 304 grade of 10mm thickness Steam jacket: MS Boiler / SS 304 of 10 mm thickness Door :Thick Stainless Steel door of 15mm thick For Double Door Option: two thick SS doors of 15mm thickness, one opening in sterile area and the other opening in non sterile area Outer cabinet: Stainless steel 304 grade of 1mm thick - mirror finish Other fittings: Piping: Stainless steel 316 grade good quality seamless Fittings: Stainless steel 316 grade with B.S.P thread Radial locking assembly: MS chrome plated or SS with CI lock with radial arm or Sliding Door arrangement. Stand: MS / SS round pipe Insulation: Rock wool slabs 50mm thick Gasket: Silicon jointless
Stainless steel carriage being half way in the rectangular sterilizer with easily maneuverable trolley
Horizontal cylindrical sterilizer with an electric steam generator resting on a robust stand
Optional Accessories : • S.S. Loading carriage (1 no.) & S.S. Transfer trolley (2 Nos). • Vacuum Pump water immersion type. • Semi-Automatic model with Printing facility (date, time, temperature and pressure) on EPSON 80 column dot matrix printer (printer not supplied). • Datalogger: 8 channel with Printer Interface/PC software. • Thermograph Circular type, single channel. • Interlocking system for Double Door models: When one door opened the other cannot be opened. • Flush mounting system: Increases the aesthetics of the equipment by having a Stainless Steel Sheet on the Sterile side of the equipment flushed with the wall. • Fully automatic cycle through PLC (PLC with computer based system with Printer). Technical Details: The system is equipped with a PC based Controlled Process Management System. The process is programmable for selecting: - Number of pulses, vacuum strength for pulse, sterilization time, operating temperature & pressure, drying time & post vacuum strength- all these parameters selectable & programmable as per requirement. - Fully Automatic operation. - Self diagnostic system is incorporated in microprocessor programming & fault / error message with indication & alarm on system failure. - Manual operating arrangement is also provided in case of auto system failure for emergency use. - Equipped with a printer for printing key process parameters like name of organization, batch no., date, time, no. of pulsing time of pulsing, temperature sterilization holding period, pressure, post vacuum & cycle over for every sterilization process and periodically at an interval of one minutes (variable) using a dot-matrix printer.
R
OSWORLD Experiment With The Truth
Osworld Range of Products
Stability Chamber BOD Incubator
ty
ili Walk-in-Stab
Oven Gravity Convection
Autoclave Steam Sterilizer Bacteriological Incubator BOD Incubator Cooling Incubator Deep Freezer Muffle Furnace
Oven Photostability Chamber Stability Chamber Vacuum Oven Walk in Stability Chamber
ISO 9001: 2008 Certified Organization
R
OSWORLD Experiment With The Truth
Clients International Clients • Access Industrial Systems Pvt. Ltd., Sri Lanka • Al Bayan Technical Equipment Est., U.A.E • Al Razi ChemicalInd’s Trading LLC, U.A.E • Alco Pharmaceuticals Ltd., Bangladesh • Alive Pharmaceuticals Pvt. Ltd., Nepal • Amulet Pharmaceuticals Ltd., Bangladesh • Apex Pharmaceuticals Pvt. Ltd., Nepal • Asian Pharmaceuticals Pvt. Ltd., Nepal • Bio Pharm Industries, Algerie • Chemi Drug Industries Pvt. Ltd., Nepal • Consolidated Pharma Industries, Sudan • Crystal Pharmaceuticals, Bangladesh • CTL Pharmaceuticals , Nepal • Curex Pharmaceuticals Pvt. Ltd., Nepal • Deurali Janta Pharmaceuticals Pvt. Ltd., Nepal • Delta Pharmaceuticals Ltd., Bangladesh • Elder Universal Pharmaceuticals (Nepal) Pvt. Ltd., Nepal • Eskay Therapeutics Ltd., Ghana • Everest Pharmaceuticals Pvt. Ltd., Nepal • G D Pharmaceuticals Pvt. Ltd., Nepal
• IBN Sina Pharmaceuticals Ltd., Bangladesh • Mark Formulations Pvt. Ltd., Nepal • Maks Pharmaceuticals Ltd., Bangladesh • Medivet Pharmaceuticals Pvt. Ltd., Nepal • National Healthcare Pvt. Ltd., Nepal • Nepal Pharmaceuticals Laboratory Pvt. Ltd., Nepal • Product Proforma, Czech Republic • Premier Pharmaceuticals Ltd., Bangladesh • Quest Pharmaceuticals Pvt. Ltd., Nepal • Red River Pharma, U.S.A • S N Pharmaceuticals Ltd., Bangladesh • S R Drugs Pvt. Ltd. , Nepal • Shiba Pharmaceuticals, Yemen • Syarikat Bumi Sains, West Malaysia • Time Pharmaceuticals Pvt. Ltd., Nepal • Unimed Pharmaceuticals Ltd., Bangladesh • Unique Pharmaceuticals (P) Ltd., Nepal • Universal Pharmaceuticals Pvt. Ltd., Nepal • Vijayadeep Laboratories Ltd., Nepal • Yemen Egyptian Pharma, Yemen
Domestic Clients • Alkem Laboratories Ltd., Mumbai • Aurobindo Pharma Ltd., Hyderabad • Bhabha Automic Research Centre, Mumbai • Cadila Healthcare Ltd., Ahmedabad, Sikkim • Central Drug Testing Laboratory, Mumbai • Cipla Ltd., Mumbai • Concept Pharmaceuticals Ltd., Aurangabad • Defence Research & Development Estt, Gwalior • Dr. D.Y. Patil Institute, Mumbai • Dr. Reddy's Laboratories Ltd., Hyderabad • Dr. Sabharwal's Wound Care, Baddi • E.I. Dupont Ltd., Hyderabad • Fritolay India Ltd., Pune • Glaxo Smithkline Ltd., Hyderabad • Glenmark Pharmaceutical Ltd., Mumbai, Pune, Nashik, Goa • Godfrey Philips India Ltd., Mumbai • Glochem Industries Ltd., Hyderabad/Vishakapatnam • Haffkine Pharmaceuticals, Pune, Mumbai • Hindustan Unilever Ltd., Mumbai • Incozen Therapeutics Pvt. Ltd., Hyderabad • Indian Drugs & Pharmaceuticals Ltd., Rishikesh • Indian Institute of Technology, Mumbai • Indoco Remedies Ltd., New Mumbai • Ipca Laboratories Ltd., Silvassa, Ratlam, Indore • Lilavati Hospital, Mumbai • Lupin Ltd., Tarapur, Mumbai • Macleod Pharma Ltd., Mumbai • Maneesh Pharmaceuticals Ltd, Baddi
• Manipal Accadimy of Higher Education, Mangalore • Merck Specialties Pvt. Ltd., Mumbai • MSN Laboratories Ltd., Hyderabad • Nicholas Piramal Ltd., Mumbai • Orchid Chemicals & Pharmaceuticals Ltd., Chennai • Orient Fans Ltd., Kolkata • Parle Agro Pvt. Ltd., Mumbai • Pfizer Ltd., New Mumbai • Pharmasolve Specialities India Pvt. Ltd., Mumbai • Pidilite Industries Ltd., Mumbai, Vapi • Piramal Healthcare Ltd., Mumbai • Ranbaxy Laboratories Ltd., Mumbai • Raptakos Brett & Company Ltd., Mumbai • Reliance Life Sciences Pvt. Ltd., New Mumbai • Richer Themis Ltd., Vapi • S. Kant Healthcare Ltd., Vapi • Sandoz Private Ltd., Thane • Sarvotherm Healthcare Pvt. Ltd., Baddi • Sun Pharmaceuticals Industries Ltd., Baroda • Themis Medicare Ltd., Vapi • Unichem Laboratories Ltd., Goa • Unimark Remedies Ltd., Ahmedabad • US Vitamin Ltd., Mumbai • Vet India Pharmaceuticals, Hyderabad • Wallace Pharmaceuticals Ltd., Goa, Baddi • Wockhardt Ltd., Aurangabad, Baddi • Zydus Cadila Ltd., Ahmedabad, Goa • Zenotech Laboratories Ltd., Hyderabad Ane Many More...
R
OSWORLD Experiment With The Truth
Admin Office: B-44, New Empire Industrial Premises, Kondivita Road, J.B. Nagar, Andheri (E), Mumbai - 400 059, India. Phone : +91-22-28320880 / 28390487, Fax : +91-22-66916595 Email : info@osworldindia.com Website : www.osworldindia.com Factory: Olympus Industrial Estate, Off Layoff Road, Mahakali Caves Road, Andheri - (East), Mumbai - 400 093, India.
ISO 9001: 2008 Certified Organization