SINGLE COMMERCIAL AIR CONDITIONERS 2 0 1 8
LG Electronics http://www.lg.com/global/business http://partner.lge.com/global http://blog.lghvacstory.com/
Copyright © 2018 LG Electronics. All rights reserved.
Distributed by
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CONTENTS
04
05
06
What is Inverter?
Why LG Smart Inverter?
Core Benefits of LG Single Commercial Smart Inverter • Energy Saving
• Comfort
• Reliability
12
14
Line up
Indoor Units • Ceiling Suspended • Ceiling Cassette • Floor Standing • Ceiling Concealed Duct
02 | 03
2018 SINGLE COMMERCIAL AIR CONDITIONERS
WHAT IS INVERTER?
WHY LG SMART INVERTER?
Traditional compressors normally cease operation once the set temperature has been reached, then start again when the room gets warmer. This results in inefficient energy usage that increases energy bills. LG’s Smart Inverter Single Split air conditioners on the other hand, operate much more efficiently, slowly decreasing and increasing output depending on the temperature outside and inside. This ultimately improves energy efficiency, as the air conditioner is able to control operational capacity.
LG Inverter technology is applied to various electronics including refrigerators and washing machines which continuously receive global attention. Their best quality is the excellent level of technology provided by LG, a reputable electronic provider. LG is also known for its comprehensive HVAC provider while continuing innovation in technology. LG’s latest Smart Inverter Single Split solutions are all equipped with the company’s advanced Smart Inverter technology.
The Advantages of Inverter Control Less Cooling Total HVAC Solution
Uncomfortable Maintain optimum temperature steadily
30%
Quick cooling
High Reputation as Inverter Technology
Pressure Controller Temperature Controller
Comfortable
Setting Temperature
Uncomfortable
LG Smart Inverter
Repeat rise and drop of temperature
Over Cooling
Inverter air conditioner
Non - inverter air conditioner
Brain
Dimmable lamp
Non inverter running at constant-speed has only two choices ; RUN or STOP. It runs at single speed without judging the ambient conditions. In contrast, Inverter operating at variable speed, can adjust its pace in the most efficient way.
Constant speed runs only ON/OFF operation, while variable STOP RUN INVERTER RUN FAST speed adjusts its frequency upon external conditions, just like SPURT RUN / STOP VS. its brightness by ambient dimmable lighting can be controlled light. WALKING SPURT
100% STOP
0%
100%
60%
20%
STOP STOP WALKINGRUN RUNWALKING RUN
WALKING
INVERTER INVERTER INVERTER SPURT
RUN / STOP RUN / STOP RUN / STOP
SPURT SPURT RUN FAST RUN FAST RUN FAST
VS. VS.VS.
Constant Compressor
SPURT
SPURT SPURT
Inverter Compressor
Constant Compressor
Energy Saving
Comfort
Reliability
More Efficient 47%
30% Quick Cooling
Wide Operation Range
Inverter Compressor
04 | 05
2018 SINGLE COMMERCIAL AIR CONDITIONERS
ENERGY SAVING Energy Saving Ratio compared to Constant Speed
high
high
More Cooling
Outdoor temp. Rated capacity
middle
Elec.Consumption (W)
External conditions can even change every minute. So LG Smart compressor runs fast during the hottest time of day and slows down when the temperature drops. In this way, it finds the optimal running conditions to save the most energy. Temperature (°C)
LG’s latest Smart Inverter Single Split solutions are all equipped with the company’s advanced Smart Inverter technology. Unlike traditional constant speed compressors, LG’s Smart Inverter compressor brings an entirely different level of intelligence to all air solutions that it is installed in.
middle
CASSETTE Max 24% FLOOR STANDING Max 14%
Constant Speed Compressor
CEILING CONCEALED DUCT Max 47%
ENERGY SAVING
Smart Inverter Compressor
low 1
2
3
4
5
6
7
low 8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Time (min)
CONSTANT SPEED COMPRESSOR
Constant-speed Compressor vs. Inverter Compressor The compressor cleverly adjusts output according to its surroundings, bringing a number of benefits including world-class energy efficiency, improved comfort and sustained reliability.
Supply of energy Waste of energy Required energy
CONSTANT SPEED COMPRESSOR 100% Operation (60Hz) 09:00
12:00
100% Operation (60Hz) 14:00
Wasting energy
Less cooling
Wasting energy
Energy saving
More cooling
Energy saving
LG SMART INVERTER COMPRESSOR
100% Operation (60Hz) 16:00
18:00
Time (min)
LG SMART INVERTER COMPRESSOR
Supply of energy Required energy
30% Operation (30Hz) 09:00
12:00
80% Operation (50Hz) 14:00
30% Operation (30Hz) 16:00
Maximized Energy Efficiency
18:00
Time (min)
06 | 07
2018 SINGLE COMMERCIAL AIR CONDITIONERS
COMFORT While constant speed compressors often create irregular temperature differences due to their stop-start operation nature, LG’s Smart Inverter compressor maximizes user comfort by adjusting output to ensure that room temperature remains at the set temperature. Users will also benefit from the quick-cooling capabilities.
Comfort Cooling Compared to constant speed with irregular temperature difference due to on / off operation, LG Smart Inverter maximizes user comfort with optimal operation adjusted to set temperature. CONSTANT SPEED COMPRESSOR
Room Temp. Target Temp.
SMART INVERTER COMPRESSOR
Room Temp. Target Temp.
Low Noise LG Smart Inverter makes lower noise than constant speed due to adjustable compressor frequency according to the load. CONSTANT SPEED COMPRESSOR
SMART INVERTER COMPRESSOR
Quick Cooling LG Smart Inverter senses not only temperature but also pressure, making precise and quick cooling possible. SMART SENSORS
Temperature Sensor
Maximum Capacity
+
If the temperature outside gets extremely hot, the LG Smart Inverter is capable of maximizing an air conditioner’s performance above its rated in order to cool effectively.
Pressure Sensor Sensing and ready for operation
Quick and reliable operation
* 30% faster than the constant speed
08 | 09
2018 SINGLE COMMERCIAL AIR CONDITIONERS
RELIABILITY Ideal for regions with unstable electricity supply, LG’s Smart Inverter Single Split air conditioners operate at a higher degree of stability and reliability with wide operation range.
High and Low Voltage Protection When abnormal voltage supplied, LG Smart Inverter compressor automatically shuts down and assures its reliability. However, constant-speed compressor has higher risk of damage. HIGH RISK OF COMPRESSOR FAILURE
COMPRESSOR PROTECTION
Corrosion Resistant Heat Exchanger The gold-colored special coating on the fin of the heat exchanger prevents corrosion, extending the life of the unit.
Anticorrosive Layer
Wide Operation Range LG’s superior compressor technologies guarantee stable performance across a wide range of temperatures.
Aluminum Anticorrosive Layer Hydrophilic Layer
Easy Maintenance and Service : LG MV LG MV (Monitoring View) helps engineers to inspect and monitor air conditioning unit easily.
Laptop
Mobile
LG MV provides cycle information with diagrams and the user can check accumulated data on a graph. A technician can easily check the error status by looking at the indicator information. (Troubleshooting guide) 10 | 11
2018 SINGLE COMMERCIAL AIR CONDITIONERS
LINE UP Capacity (Btu/h) Power Supply
18,000
24,000
30,000 1 Phase 220-240V / 50Hz
36,000
48,000
36,000
42,000
48,000
54,000
60,000
100,000
150,000 / 200,000
3 Phase 380-410V / 50Hz
Product
Ceiling Suspended
Ceiling Cassette
Floor Standing
Ceiling Concealed Duct (Low Static)
Ceiling Concealed Duct (Mid Static)
12 | 13
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING SUSPENDED Differentiated Design With its stunning V-shaped design and black vane, LG’s new ceiling-suspended air conditioner exudes modern elegance appropriate for any space. The tasteful aesthetics of the air conditioner helped earn it the iF Design Award.
Powerful Cooling & Heating The new LG Ceiling Suspended Unit is efficient for using in large areas due to its powerful cooling and heating operation. The powerful air speed and volume means the air flow can reach up to 15m away from the air conditioner.
15M 15M With enlarged outlet space, optimized the Air flow Path and improved Heat Exchanger’s performance
Outlet Space New LG
Optimized the Air flow Path Velocity in Stn Frame Contour 1 2,000e+00 1,800e+00 1,600e+00 1,400e+00 1,200e+00 1,000e+00 8,000e+00 6,000e+00 4,000e+00 2,000e+00 0,000e+00 [m s^-1]
Conventional
115% ENLARGED
1 1 1 1 1 1 0 0 0 0 0
Velocity in Stn Frame Contour 1 2,000e+00 1,800e+00 1,600e+00 1,400e+00 1,200e+00 1,000e+00 8,000e+00 6,000e+00 4,000e+00 2,000e+00 0,000e+00 [m s^-1]
1 1 1 1 1 1 0 0 0 0 0
ANSYS R15. 0
ANSYS R15. 0
105% IMPROVED 14 | 15
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING SUSPENDED One Touch & 2 Piece Filter
Specifications
Easy in / out filter structure as well as a simplified two-piece filter, which slides out for easy cleaning and maintenance.
* Wireless Remote Controller Included
Set Condition
Two Thermistors Control Users can purchase an optional control panel that includes a second thermistor, allowing for temperature checks from multiple locations.
Indoor Unit Thermistor
Two
Thermistors
Remote Controller Thermistor
CEILING CEILING & F LOOR E RTIBL &CEILING FCONVE LOOR&RTIBL CONVE E RTIBL E F LOOR CONVE UNIT CEILING SUSPENDED UN SUSPENDED IT UN IT UN IT UNIT CEILING UNITSUSPENDED CEILING
One Touch Filter
Outdoor unit
AVUQ18GM1A1
AVUQ24GM1A1
AVUQ30GM1A1
AVUQ36GM2A1
Indoor unit
AVNQ18GM1A1
AVNQ24GM1A1
AVNQ30GM1A1
AVNQ36GM2A1
Capacity
Cooling
Min/Rated/Max
Power Input
Cooling
Rated
Running Current
Cooling
Rated
1.58 ~ 5.27 ~ 5.95
2.11 ~ 7.03 ~ 7.90
2.64 ~ 8.79 ~ 9.88
3.17 ~ 10.55 ~ 11.67
5,400 ~ 18,000 ~ 20,300
7,200 ~ 24,000 ~ 26,900
9,000 ~ 30,000 ~ 33,700
10,800 ~ 36,000 ~ 39,800
kW
1.50
2.00
2.70
3.20
A
7.50
9.20
12.40
14.70
kW Btu/h
EER / COP
W/W
3.52
3.52
3.25
3.3
SEER
-
19.5
19.5
18.5
18.5
Indoor Unit
AVNQ18GM1A1
AVNQ24GM1A1
AVNQ30GM1A1
AVNQ36GM2A1
V , Ø , Hz
220-240, 1, 50/60
220-240, 1, 50/60
220-240, 1, 50/60
220-240, 1, 50/60
W×H×D
mm
1,200 × 235 × 690
1,200 × 235 × 690
1,200 × 235 × 690
1,600 × 235 × 690
W×H×D
inch
47-1/4 × 9-1/4 × 27-5/32
47-1/4 × 9-1/4 × 27-5/32
47-1/4 × 9-1/4 × 27-5/32
63 × 9-1/4 × 27-5/32
28.0 (61.7)
28.0 (61.7)
28.0 (61.7)
35.0 (77.2)
CFF
CFF
CFF
CFF
Power Supply Dimensions Net Weight
Fan
Body Body
kg (lbs)
Type
-
Air Flow Rate
H/M/L
m3/min
13.5 / 12.5 / 12.0
18.0 / 16.0 / 13.0
20.0 / 18.0 / 16.0
27.0 / 24.0 / 20.0
H/M/L
ft3/min
477 / 441 / 424
636 / 565 / 459
706 / 636 / 565
953 / 848 / 706
1.4 (2.9)
2.4 (5.1)
2.4 (5.1)
2.7 (5.7)
H/M/L
37 / 35 / 33
47 / 44 / 38
48 / 46 / 44
48 / 46 / 44
Liquid
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
4C × 0.75 (18)
4C × 0.75 (18)
4C × 0.75 (18)
4C × 0.75 (18)
AVUQ18GM1A1
AVUQ24GM1A1
AVUQ30GM1A1
AVUQ36GM2A1
220-240, 1, 50/60
220-240, 1, 50/60
220-240, 1, 50/60
220-240, 1, 50/60
3C × 2.5 (12)
3C × 4.0 (10)
3C × 4.0 (10)
3C × 4.0 (10)
Dehumidification Rate Sound Pressure Level
Piping connection
Drain (O.D. / I.D.) mm (inch) No. x mm2 (AWG)
Power and Communication Cable (included Earth)
Outdoor Unit V , Ø , Hz
Power Supply Wiring Connections
Easy Installation
Power Supply Cable (included Earth)
Dimensions
Installation speed and ease is improved by reducing the total number of screws and placing them on the easily accessible front panel.
Corner Installation Possible
4 Screws
2 Screws
W×H×D
mm
770 × 545 × 288
870 × 650 × 330
870 × 650 × 330
950 × 834 × 330
W×H×D
inch
30-5/16 × 21-15/32 × 11-11/32
34-1/4 × 25-19/32 × 13
34-1/4 × 25-19/32 × 13
37-13/32 × 32-27/32 × 13 56.0 (123.5)
Net Weight
Compressor
No. × mm2 (AWG)
kg (lbs) Type
-
Model
Model × No.
33 (72.8)
41.5 (91.5)
41.5 (91.5)
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
GAT156MAD × 1
GKT176MAG × 1
GKT208MAB × 1
GJT325MAA × 1
BLDC
BLDC
BLDC
BLDC
1,500 × 1
1,500 × 1
1,500 × 1
2,137 × 1
Motor type
-
Motor Output
W × No.
Refrigerant
Type
-
R410A
R410A
R410A
R410A
Refrigerant Oil
Type
-
RB68A
FVC68D
FVC68D
FVC68D
Heat Exchanger
(Row × Column × Fins per inch) × No.
(2 × 25 × 21) × 1
(2 × 30 × 21) × 1
(2 × 30 × 21) × 1
(2 × 40 × 21) × 1
Fan
Type
-
Propeller
Propeller
Propeller
Propeller
Fan Motor
Type
-
BLDC
BLDC
BLDC
BLDC
Sound Pressure Level
Cooling
Rated
dB(A)
47
53
53
58
Liquid
Outer Dia.
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
Outer Dia.
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Max.
m (ft)
30 (98.4)
50 (164.0)
50 (164.0)
50 (164.0)
Outdoor Unit Max. ~ Indoor Unit
m (ft)
15 (49.2)
30 (98.4)
30 (98.4)
30 (98.4)
Piping Connections Piping Length Maximum Height Difference
16 | 17
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING SUSPENDED Specifications
Memo
* Wireless Remote Controller Included
Set Condition
Capacity
Outdoor unit
AVUQ36LM2A1
AVUQ48LM2A1
AVUW60LM2A1
Indoor unit
AVNQ36LM2A1
AVNQ48LM2A1
AVNW60LM2A1
Cooling
Min/Rated/Max
kW Btu/h
3.17 ~ 10.55 ~ 11.67
4.22 ~ 14.06 ~ 15.43
4.84 ~ 16.12 ~ 17.73
10,800 ~ 36,000 ~ 39,800
14,400 ~ 48,000 ~ 52,500
16,503 ~ 55,000 ~ 60,510 5.28
Power Input
Cooling
Rated
kW
3.20
4.90
Running Current
Cooling
Rated
A
5.20
8.00
8.4
EER / COP
W/W
3.3
2.87
3.05
SEER
-
18.5
16.3
16.0
Indoor Unit
AVNQ36LM2A1
AVNQ48LM2A1
AVNW60LM2A1
V , Ø , Hz
220-240, 1, 50/60
220-240, 1, 50/60
220-240, 1, 50/60
W×H×D
mm
1,600 × 235 × 690
1,600 × 235 × 690
1,600 × 235 × 690
W×H×D
inch
63 × 9-1/4 × 27-5/32
63 × 9-1/4 × 27-5/32
63 × 9-1/4 × 27-5/32
35.0 (77.2)
35.0 (77.2)
35.0 (77.2)
CFF
CFF
CFF
Power Supply Dimensions Net Weight
Fan
Body Body
kg (lbs)
Type
-
Air Flow Rate
H/M/L
m3/min
27.0 / 24.0 / 20.0
29.0 / 24.0 / 20.0
30.0 / 25.0 / 20.0
H/M/L
ft3/min
953 / 848 / 706
1,024 / 848 / 706
1,059 / 883 / 706
2.7 (5.7)
5.0 (10.5)
6.13 (12.9)
48 / 46 / 44
50 / 47 / 44
50 / 47 / 44
Dehumidification Rate H/M/L
Sound Pressure Level
Piping connection
Liquid
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 19.05 (3/4)
Ø 21.5 (27/32) / 16.0 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
Ø 21.5 (27/32) / 16.0 (5/8)
4C × 0.75 (18)
4C × 0.75 (18)
4C × 0.75 (18)
AVUQ36LM2A1
AVUQ48LM2A1
AVUW60LM2A1
380-415, 3, 50/60
380-415, 3, 50/60
380-415, 3, 50/60
5C × 2.5 (12)
5C × 2.5 (12)
5C × 2.5 (12)
Drain (O.D. / I.D.) mm (inch) Power and Communication Cable (included Earth)
No. x mm2 (AWG)
Outdoor Unit V , Ø , Hz
Power Supply Wiring Connections
Power Supply Cable (included Earth)
Dimensions
W×H×D
mm
950 × 834 × 330
950 × 834 × 330
950 × 1,170 × 330
W×H×D
inch
37-13/32 × 32-27/32 × 13
37-13/32 × 32-27/32 × 13
37-13/32 × 32-27/32 × 13 79.1 (174.4)
kg (lbs)
57.5 (126.8)
67 (147.7)
Type
-
Twin Rotary
Twin Rotary
Twin Rotary
Model
Model × No.
GJT325MAA × 1
GPT442MAB × 1
GPT442MAB x 1
Motor type
-
Motor Output
W × No.
Net Weight
Compressor
No. × mm2 (AWG)
BLDC
BLDC
BLDC
2,137 × 1
4,000 × 1
4,000 × 1
Refrigerant
Type
-
R410A
R410A
R410A
Refrigerant Oil
Type
-
FVC68D
FVC68D
FVC68D
Heat Exchanger
(Row × Column × Fins per inch) × No.
(2 × 40 × 21) × 1
(3 × 40 × 21) × 1
(2 × 32 × 14) × 2
Fan
Type
-
Propeller
Propeller
Propeller
Fan Motor
Type
-
BLDC
BLDC
BLDC
Sound Pressure Level
Cooling
Rated
dB(A)
58
56
55
Liquid
Outer Dia.
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 19.05 (3/4)
Max.
m (ft)
50 (164.0)
50 (164.0)
50 (164.0)
Outdoor Unit Max. ~ Indoor Unit
m (ft)
30 (98.4)
30 (98.4)
30 (98.4)
Piping Connections Piping Length Maximum Height Difference
18 | 19
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CASSETTE High Ceiling Mode High ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.
High Ceiling Mode
4.2 4
General 3
2.7 2.4
2
1
1 (mm)
2
4
3
2
1
0
1
2
3
4
Independent Vane Operation The independent vane operation feature uses separate motors, making it possible to control all four vanes independently. ALL VANE OPERATION
INDEPENDENT VANE CONTROL
Direct Air Flow
Indirect Air Flow
* Wired remote controller PQRCVSL0 (QW) applied
20 | 21
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CASSETTE Compact Size
Quiet Operation with 3D Fan
The indoor unit with slim and compact dimensions has reduced the restriction which enables successful installation in various spaces.
New technology of 3D fan is applied to Inverter cassettes. It increases air flow but reduces noise.
4dB (A) Standard Inverter
Height
18 ~ 24kBtu
204mm
30 ~ 36kBtu
246mm
48kBtu
288mm
46dB (A) 42dB (A)
Length x Width : 840mm x 840mm
Conventional
New
* Cassette 36kBtu
Prevent Ceiling Pollution Coanda design of air outlet can prevent contamination of ceiling. CONVENTIONAL
COANDA DESIGN
Product Product Ceiling Ceiling Louver Louver
Ceiling Ceiling PollutionsPollutions
Product Product Ceiling Ceiling Louver Louver Conventional New
Blade Angle Changed : Increase air flow and decrease noise
Curved Leading Edge : Improve air flow in same RPM of conventional fans
22 | 23
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CASSETTE Specifications
Specifications
* Wireless Remote Controller Included
Combination
* Wireless Remote Controller Included
Outdoor unit Indoor unit kW
ATUQ18GPLE6
ATUQ24GPLE6
ATNQ18GPLE6
ATNQ24GPLE6
1.58 ~ 5.27 ~ 6.01
2.11 ~ 7.03 ~ 7.68
5,400 ~ 18,000 ~ 20,500
7,200 ~ 24,000 ~ 26,200
Capacity
Cooling
Min/Rated/Max
Power Input
Cooling
Rated
kW
1.53
Running Current
Cooling
Rated
A
6.70
W/W
EER / COP
Btu/h
Indoor Unit V , Ø , Hz
Power Supply Dimensions
Body
Net Weight
Body
kg (lbs)
Type
-
Fan
Air Flow Rate
W×H×D
H/M/L
mm
m3/min
Combination
Outdoor unit Indoor unit kW
Power Input
Cooling
Rated
kW
3.50
4.49
Running Current
Cooling
Rated
A
15.10
19.50
3.45
3.24
EER / COP
W/W
3.01
3.01
ATNQ18GPLE6
ATNQ24GPLE6
Indoor Unit
ATNQ36GNLE6
ATNQ48GMLE6
220-240, 1, 50/60
220-240, 1, 50/60
Power Supply
220-240, 1, 50/60
220-240, 1, 50/60
840 × 204 × 840
840 × 204 × 840
Dimensions
Body
840 × 246 × 840
840 × 288 × 840
19.6 (43.2)
19.7 (43.4)
Net Weight
Body
kg (lbs)
23.3 (51.4)
25.5 (56.2)
Turbo Fan
Turbo Fan
Type
-
17.0 / 15.0 / 13.0
18.0 / 16.0 / 14.0
Fan
V , Ø , Hz
Air Flow Rate
W×H×D
H/M/L
mm
m3/min
2.1 (4.5)
2.1 (4.5)
Dehumidification Rate
ℓ/h (pts/h)
40 / 38 / 36
Sound Pressure Level
dB(A)
Liquid
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Drain (O.D. / I.D.)
mm (inch)
Ø 32.0 (1-1/4) / 25.0 (31/32)
Ø 32.0 (1-1/4) / 25.0 (31/32)
PT-UMC1
PT-UMC1
950 × 25 × 950
950 × 25 × 950
5.0 (11.0)
5.0 (11.0)
ATUQ18GPLE6
ATUQ24GPLE6
220-240, 1, 50/60
220-240, 1, 50/60
WxHxD
Net weight
mm kg (lbs)
Outdoor Unit Power Supply
V , Ø , Hz
Wiring Connections
No. × mm2 (AWG)
Power Supply Cable (included Earth) W×H×D
Dimensions
mm kg (lbs)
Net Weight
Decoration Panel
Twin Rotary
Twin Rotary
Compressor
Type
-
R410A
R410A
Heat Exchanger
(Row × Column × Fins per inch) × No.
-
(2 × 25 × 21) × 1
(2 × 30 × 21) × 1
Type
-
Propeller
Hubless
Air Flow Rate
m /min × No.
50 × 1
50 × 1
-
BLDC
External BLDC
47
53
Power Supply Cable (included Earth) W×H×D
mm
950 × 25 × 950
5.0 (11.0)
5.0 (11.0)
ATUQ36GNLE6
ATUQ48GMLE6
220-240, 1, 50/60
220-240, 1, 50/60
3C × 4.0 (10)
3C × 6.0 (6)
950 × 834 × 330
950 × 834 × 330
Refrigerant
Type
-
R410A
R410A
Heat Exchanger
(Row × Column × Fins per inch) × No.
-
(2 × 40 × 21) × 1
(3 × 40 × 21) × 1
Type
-
Propeller
Propeller
Air Flow Rate
m /min × No.
70 × 1
70 × 1
-
BLDC
BLDC
Fan
Outer Dia.
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Gas
Outer Dia.
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Max.
m (ft)
30 (98.4)
50 (164.0)
Piping Length
30 (98.4)
Maximum Height Difference
Note : 1. Wiring cable size must comply with the applicable local and national codes. 2. Due to our policy of innovation some specifications may be changed without notifications. 3. Sound Level Values are measured at Anechoic chamber.Therefore, these values can be increased owing to ambient conditions during operation.
kg (lbs)
PT-UMC1
950 × 25 × 950
67 (147.7)
Liquid
15 (49.2)
mm
Twin Rotary
dB(A)
m (ft)
WxHxD
Twin Rotary
Rated
Max.
Ø 32.0 (1-1/4) / 25.0 (31/32)
PT-UMC1
-
Cooling
Outdoor Unit ~ Indoor Unit
Ø 32.0 (1-1/4) / 25.0 (31/32)
-
Type
Type
Maximum Height Difference
mm (inch)
56.0 (123.5)
Sound Pressure Level
Piping Length
Drain (O.D. / I.D.)
kg (lbs)
Fan Motor
Piping Connections
Ø 9.52 (3/8) Ø 15.88 (5/8)
Wiring Connections
Net Weight
Refrigerant
Ø 9.52 (3/8)
No. × mm2 (AWG)
Dimensions
3.6 (7.7) 44 / 42 / 40
Ø 15.88 (5/8)
V , Ø , Hz
41.5 (91.5)
2.7 (5.7) 42 / 40 / 38
mm (inch)
Power Supply
870 × 650 × 330
32.0 / 30.0 / 28.0
mm (inch)
Outdoor Unit
33 (72.8)
Turbo Fan
23.0 / 21.0 / 19.0
Gas
Net weight
770 × 545 × 288
-
Dimension
Turbo Fan
Liquid
Model Name
3C × 4.0 (10)
Type
3
Piping connection
3C × 2.5 (12)
Compressor
Fan
13,800 ~ 46,000 ~ 49,500
9.50
36 / 34 / 32
Dimension
4.05 ~ 13.5 ~ 14.5
10,800 ~ 36,000 ~ 39,400
2.17
Btu/h
dB(A)
Decoration Panel
ATNQ48GMLE6
3.15 ~ 10.5 ~ 11.55
Min/Rated/Max
ℓ/h (pts/h)
-
ATNQ36GNLE6
Cooling
Sound Pressure Level
Model Name
ATUQ48GMLE6
Capacity
Dehumidification Rate
Piping connection
ATUQ36GNLE6
3
Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
Liquid
Outer Dia.
Gas
Piping Connections
Outdoor Unit ~ Indoor Unit
58
56
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Max.
m (ft)
50 (164.0)
50 (164.0)
Max.
m (ft)
30 (98.4)
30 (98.4)
Note : 1. Wiring cable size must comply with the applicable local and national codes. 2. Due to our policy of innovation some specifications may be changed without notifications. 3. Sound Level Values are measured at Anechoic chamber.Therefore, these values can be increased owing to ambient conditions during operation.
24 | 25
2018 SINGLE COMMERCIAL AIR CONDITIONERS
FLOOR STANDING Energy Efficiency Provides excellent energy saving through LG’s latest Smart Inverter technology.
Payback
4month * Based on LG internal simulation (Conventional 48kBtu vs. New Inverter 48kBtu)
Modern Design Stylish and Blended Design that fits perfectly with Office / Retail / Restaurants. Pure color of indoor unit and hidden display panel makes natural harmony with any kind of interiors.
Powerful Air Flow The new LG floor standing air conditioner is efficient for using in large areas due to its powerful cooling and heating operation. The powerful air speed and volume means the air flow can reach up to 20m away from the air conditioner.
20m 26 | 27
2018 SINGLE COMMERCIAL AIR CONDITIONERS
FLOOR STANDING Strong in Cooling Capacity
Specifications Genuine 5PK Product 5PK * Wireless Remote Controller Included 48kBtu Combination (Rated) 46,000Btu
(Maximum) 49,000Btu
33CMM
Conventional 55dB(A)
Power Input
Cooling
Rated
kW
4.49
Cooling
Rated
A
19.50
W/W
3.01
Btu/h
V , Ø , Hz
Casing Color
-
Dimensions
Body
Net Weight
Body
Sound Pressure Level
Cooling
Piping connection
W×H×D
mm kg (lbs)
SH / H / M / L
dB(A)
New
New
49dB(A)
because it’s Made in KOREA. - All Floor Standing Indoor Unit made in KOREA - Outdoor Unit Compressor made in KOREA * 48kBtu Compressor made in KOREA
47.0 (103.6) 52 / 49 / 47 / 45
mm (inch)
Ø 9.52 (3/8)
mm (inch)
Ø 15.88 (5/8)
Drain (O.D. / I.D.)
mm (inch)
Ø 21.0 / 17.0
-
Power and Communication Cable (included Earth)
No. × mm2 (AWG)
Fuse 4C × 0.75 (18)
APUQ48GT3E3
Power Supply
V , Ø , Hz
Wiring Connections
No. × mm2 (AWG)
Power Supply Cable (included Earth) W×H×D
Net Weight
Guarantee the Quality & Reliability
White 590 × 1,840 × 440
Liquid
Safety Devices
Dimensions
Made in KOREA
220-240, 1, 50/60
Gas
Outdoor Unit
Conventional
13,800 ~ 46,000
APNQ48GT3E3
Power Supply
30CMM
33CMM
4.05 ~ 13.5
Running Current
Indoor Unit
3CMM
APNQ48GT3E3 kW
Min / Rated
Using new technology fan, LG provides strong Air flow rate and Low noise level. Noise Level
Indoor unit Cooling
EER / COP
Airflow Rate
APUQ48GT3E3
Capacity
4Way Auto Swing (New FAN Technology) 4Way Auto Swing
Outdoor unit
mm
220-240, 1, 50/60 3C × 6.0 (6) 950 × 834 × 330
kg (lbs)
67 (147.7) Twin Rotary
Compressor
Type
-
Refrigerant
Type
-
R410A
Heat Exchanger
(Row × Column × Fins per inch) × No.
-
(3 × 40 × 21) × 1
Type
-
Propeller
Air Flow Rate
m3/min × No.
70 x 1
mm (inch)
BLDC
Fan
Fan Motor
Type
Sound Pressure Level
Cooling
Piping Connections
dB(A)
56
Liquid
Outer Dia.
mm (inch)
Ø 9.52 (3/8)
Gas
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Max.
m (ft)
50 (164.0)
Max.
m (ft)
30 (98.4)
Piping Length Maximum Height Difference
Rated
Outdoor Unit ~ Indoor Unit
28 | 29
2018 SINGLE COMMERCIAL AIR CONDITIONERS
FLOOR STANDING Specifications
Specifications
* Wireless Remote Controller Included 48kBtu
* Wireless Remote Controller Included
100kBtu
Combination
Outdoor unit
APUQ48LT3E3
APUQ100LFA0
Indoor unit
APNQ48LT3E3
APNQ100LFA0
Capacity
Cooling
Min / Rated
Power Input
Cooling
Rated
Running Current
Cooling
Rated
EER / COP
4.05 ~ 13.5
14.3 ~ 28.7
13,800 ~ 46,000
49,000 ~ 98,000
kW
4.49
A
6.70
W/W
kW
Outdoor unit
APUQ150LNA0
APUQ200LNA0
Indoor unit
APNQ150LNA0
APNQ200LNA0
18.8 ~ 46.9
23.4 ~ 58.6
64,200 ~ 160,000
79,900 ~ 200,000
kW
16.1
21.0
A
22.0
28.2
W/W
2.91
2.79
Indoor Unit
APNQ150LNA0
APNQ200LNA0
Power Supply
V , Ø , Hz
220-240 , 1 , 50 220 , 1 , 60
220-240 , 1 , 50 220 , 1 , 60
Power Input
W
660
830
Running Current
A
3.0
3.8
1,558 × 1,920 × 700
1,558 × 1,920 × 700
237.0 (522.5)
237.0 (522.5)
Capacity
Cooling
Min / Rated
11.5
Power Input
Cooling
Rated
19.5
Running Current
Cooling
Rated
3.01
2.5
EER / COP
APNQ48LT3E3
APNQ100LFA0
V , Ø , Hz
220-240, 1, 50/60
220-240, 1, 50 220, 1, 60
mm
Btu/h
Indoor Unit Power Supply
Combination
kW Btu/h
Dimensions
Body
590 × 1,840 × 440
1,050 × 1,880 × 495
Net Weight
Body
kg (lbs)
47.0 (103.6)
113.0 (249.0)
Type
-
Sirocco Fan
Sirocco
Dimensions
Body
37.0 / 33.0 / 28.0 / 24.0
68 / 61 / - / 50
Net Weight
Body
kg (lbs)
BLDC
BLDC
Type
-
Sirocco Fan
Sirocco Fan
49 / 45
55 / 51
H/L
m3/min
120.0 / 95.0
130.0 / 95.0
dB(A)
Fan Fan Motor
Air Flow Rate
W×H×D
H/L
m3/min
-
Type
dB(A)
Fan
mm
Sound Pressure Level
H/L Liquid
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Fan Motor
Piping connection
Gas
mm (inch)
Ø 15.88 (5/8)
Ø 22.2 (7/8)
Sound Pressure Level
H/L
mm
Liquid
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Piping connection
Gas
mm (inch)
Ø 28.58 (1-1/8)
Ø 28.58 (1-1/8)
Ø 21.0 / 17.0
Ø 32 / 25
Communication Cable
No. × mm2
4C × 0.75
4C × 1.5
Power Cable (Included Earth)
No. × mm2
-
-
Drain (O.D. / I.D.)
Outdoor Unit
APUQ48LT3E3
APUQ100LFA0
4.05 ~ 13.5
14.3 ~ 28.7
Min.~Rated.
kW
Min.~Rated.
Btu/h
13,800 ~ 46,000
49,000 ~ 98,000
Cooling
Rated
kW
4.49
11.5
Cooling
Rated
A
6.1
19.5
380 - 415, 3, 50/60
380 - 415, 3, 50 380, 3, 60
Capacity
Cooling
Power Input Running Current Power Supply
V , Ø , Hz
Wiring Connections
No. × mm2 (AWG)
Power Supply Cable (included Earth) W×H×D
Dimensions Net Weight
Drain (O.D. / I.D.)
BLDC
BLDC
64 / 57
65 / 57
Ø 21.0 / 17.0
mm
Ø 21.0 / 17.0
No. × mm2
2C × 1.0~1.5 (H07RN-F)
Power Cable (Included Earth)
No. × mm2
3C × 2.5 (H07RN-F)
Outdoor Unit
APUQ150LNA0 Min.~Rated.
kW
Min.~Rated.
Btu/h
APUQ200LNA0
18.8 ~ 46.9
23.4 ~ 58.6
64,200 ~ 160,000
79,900 ~ 200,000
Capacity
Cooling
Power Input
Cooling
Rated
kW
16.1
21.0
Running Current
Cooling
Rated
A
22.0
28.2
380-415 , 3 , 50 / 380 , 3 , 60
380-415 , 3 , 50 / 380 , 3 , 60
5C × 2.5 (12)
5C × 6.0 1,090 × 1,625 × 380
kg (lbs)
67 (147.7)
143.0 (315)
Twin Rotary
BLDC INV Scroll
Dimensions
Power Supply
V , Ø , Hz
Wiring Connections
No. × mm (AWG)
2
Compressor
Type
-
Refrigerant
Type
-
R410A
R410A
Net Weight
Refrigerant Oil
Type
-
FVC68D
FVC68D
Compressor
Heat Exchanger
(Row × Column × Fins per inch) × No.
-
(3 × 40 × 21) × 1
(2 × 38 × 14) × 2
Type
-
Propeller
Propeller
Air Flow Rate
m3/min
70 × 1
190 × 2
Heat Exchanger
BLDC
BLDC
56
58
Fan
-
Type
Communication Cable
950 × 834 × 330
mm
Air Flow Rate
W×H×D
Power Supply Cable (included Earth) W×H×D
mm kg (lbs)
5C x 6.0 (10)
5C x 6.0 (10)
1,240 × 1,680 × 760
1,240 × 1,680 × 760
270.0 (595.2)
270.0 (595.2)
Hermetic Motor Compressor
Hermetic Motor Compressor
Type
-
Refrigerant
Type
-
R410A
R410A
Refrigerant Oil
Type
-
FVC68D (PVE)
FVC68D (PVE)
(Row × Column × Fins per inch) × No.
-
(2 × 58 × 14) × 1
(2 × 58 × 14) × 1
Type
-
Propeller
Propeller
Air Flow Rate
m3/min
Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
Liquid
Outer Dia.
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
64
65
Liquid
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Gas
Outer Dia.
mm (inch)
Ø 28.58 (1-1/8)
Ø 28.58 (1-1/8)
Max.
m (ft)
50 (164.0)
50 (164.0)
30 (98.4)
30 (98.4)
-10 (14.0) ~ 48 (118.4)
-10 (14.0) ~ 48 (118.4)
Piping Connections
Gas
Piping Length Maximum Height Difference Operation Range (Outdoor Temperature)
Outdoor Unit ~ Indoor Unit Cooling
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 22.2 (7/8)
Max.
m (ft)
50 (164.0)
50 (164)
Max.
m (ft)
30 (98.4)
30 (98)
Min. ~ Max.
°CDB (°FDB)
-5 (24.0) ~ 48 (118.4)
-10 (14) ~ 48 (118)
Fan
Piping Connections Piping Length Maximum Height Difference
Outdoor Unit ~ Indoor Unit
Max.
m (ft)
Operation Range (Outdoor Temperature)
Cooling
Min. ~ Max.
°CDB (°FDB)
290
290
BLDC
BLDC
30 | 31
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CONCEALED DUCT E.S.P. (External Static Pressure) Control E.S.P. control function can make air volume controlled easily with remote controller. The BLDC motor can control fan speed and air volume regardless of the external static pressure. No additional accessories are necessary to control air flow. Long Piping
Conventional
Short Piping
Weak Cooling / Heating
Comfort Cooling / Heating
Comfort Cooling / Heating
E.S.P. Control
Over Cooling / Heating
High Head Drain Pump High head drain pump automatically drains water up to 200mm of drain-head height. It provides perfect solution for water drainage. (18, 24kBtu Low Static Duct Drain pump excluded) Fixture
Water drainage up to 700mm
Drain pipe slope (1/50~1/100)
Drain pipe
450mm
300mm
Flexible drain hose
Available for natural drainage Detachable drain pump
32 | 33
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CONCEALED DUCT Two Thermistors Control
Specifications
The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
* Wired Remote Controller Included
Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users.
Indoor Unit Thermistor Set Condition
Low Static
Outdoor unit Indoor unit
ABNQ24GL3A0
2.00 ~ 5.00 ~ 5.75
2.81 ~ 7.00 ~ 8.00
6,800 ~ 17,100 ~ 19,600
9,600 ~ 23,900 ~ 27,300
Min/Rated/Max
Power Input
Cooling
Rated
kW
1.55
2.32
Running Current
Cooling
Rated
A
6.70
10.10
Btu/h · W
11.01
10.30
Indoor Unit
ABNQ18GL2A0
ABNQ24GL3A0
Power Supply
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
Btu/h
V , Ø , Hz A
Dimensions
Body
Net Weight
Body
Sound Pressure Level
Piping connection
W×H×D
mm kg (lbs)
(2 × 11 × 18) × 1
(3 × 11 × 18) × 1
36 / 34 / 31
39 / 35 / 32
Liquid
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Drain (O.D. / I.D.)
mm
Ø 25.4 / 20.4
Ø 25.4 / 20.4
No. x mm2 (AWG)
4C × 0.75 (18)
4C × 0.75 (18)
ABUQ18GL2A0
ABUQ24GL3A0
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
3C × 2.5 (12)
3C × 2.5(12)
770 × 545 × 288
870 × 655 × 320
Power Supply
V , Ø , Hz Power Supply Cable (included Earth)
Dimensions
10.10 43-5/16 × 7-15/32 × 27-9/16
dB(A)
Outdoor Unit
Wiring Connections
6.70 35-7/16 × 7-15/32 × 27-9/16
H/M/L
Power and Communication Cable (included Earth)
Using a spiral duct (embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously.
ABNQ18GL2A0
Cooling
Running Current (Set)
Operation for Multiple Rooms
ABUQ24GL3A0
Capacity
EER
Remote Controller Thermistor
kW
ABUQ18GL2A0
W×H×D
Net Weight
No. × mm2 (AWG) mm kg (lbs)
34.0 (75.0)
44.0 (97.0)
Twin Rotary
Twin Rotary
Compressor
Type
-
Refrigerant
Type
-
R410A
R410A
Refrigerant Oil
Type
-
FVC68D
FVC68D
Heat Exchanger
#1_(Row × Column × Fins per inch) × No. -
(2 × 24 × 20) × 1
(2 × 30 × 21) × 1
Propeller
Propeller
50 × 1
50 × 1
BLDC
BLDC
Fan
Type
-
Air Flow Rate
m /min × No. 3
Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
Liquid
Outer Dia.
Piping Connections
Gas
Piping Length Maximum Height Difference
Outdoor Unit ~ Indoor Unit
Operation Range Cooling (Outdoor Temperature)
47
48
mm (inch)
Ø 6.35 (1/4)
Ø 9.52 (3/8)
Outer Dia.
mm (inch)
Ø 12.7 (1/2)
Ø 15.88 (5/8)
Max.
m (ft)
30 (98.4)
50 (164.0)
Max.
m (ft)
15 (49.2)
30 (98.4)
Min. ~ Max.
°CDB (°FDB)
-5 (23.0) ~ 48 (118.4)
-5 (23.0) ~ 48 (118.4)
34 | 35
2018 SINGLE COMMERCIAL AIR CONDITIONERS
CEILING CONCEALED DUCT Specifications
Specifications
* Wired Remote Controller Included Set Condition
* Wired Remote Controller Included
Mid Static
Outdoor unit Indoor unit kW
ABUQ30GGLA1
ABUQ36GGLA1
ABNQ30GGLA1
ABNQ36GGLA1
4.40 ~ 8.80 ~ 11.72
5.27 ~ 10.60 ~ 12.31
15,000 ~ 30,000 ~ 40,000
18,000 ~ 36,000 ~ 42,000
Capacity
Cooling
Min/Rated/Max
Power Input
Cooling
Rated
kW
2.72
Running Current
Cooling
Rated
A Btu/h · W
Set Condition
Mid Static
Outdoor unit
ABUQ42LRLA1
ABUQ48LRLA1
ABNQ36LGLA1
ABNQ42LRLA1
ABNQ48LRLA1
ABNQ54LRLA1
4.00 ~ 10.60 ~ 11.43
5.00 ~ 12.30 ~ 13.20
5.57 ~ 14.10 ~ 14.95
6.33 ~ 15.80 ~ 16.60
ABUQ36LGLA1
Indoor unit kW
ABUQ54LRLA1
Capacity
Cooling
Min/Rated/Max
13,600 ~ 36,000 ~ 39,000
17,000 ~ 42,000 ~ 45,000
19,000 ~ 48,000 ~ 51,000
21,600 ~ 53,900 ~ 56,600
3.30
Power Input
Cooling
Rated
kW
3.64
3.72
4.66
5.23
12.50
15.20
Running Current
Cooling
Rated
A
5.90
6.00
7.80
9.20
11.03
10.91
EER
Btu/h · W
9.89
11.29
10.30
10.30
Indoor Unit
ABNQ30GGLA1
ABNQ36GGLA1
Indoor Unit
ABNQ36LGLA1
ABNQ42LRLA1
ABNQ48LRLA1
ABNQ54LRLA1
Power Supply
V , Ø , Hz
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
Power Supply
V , Ø , Hz
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
Running Current (Set)
A
12.50
15.20
Running Current (Set)
A
EER
Dimensions
Body
Net Weight
Body
Sound Pressure Level
Piping connection
W×H×D
Btu/h
mm
Dimensions
Body
Net Weight
Body
(3 × 10 × 19) × 1
(3 × 10 × 19) × 1
dB(A)
42 / 39 / 36
42 / 39 / 36
Liquid
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Drain (O.D. / I.D.)
mm
Ø 25.4 / 20.4
Ø 25.4 / 20.4
kg (lbs)
No. x mm2 (AWG)
Outdoor Unit Power Supply
V , Ø , Hz Power Supply Cable (included Earth)
Dimensions
46-15/32 × 11-23/32 × 17-23/32
H/M/L
Power and Communication Cable (included Earth)
Wiring Connections
46-15/32 × 11-23/32 × 17-23/32
W×H×D
Net Weight
No. × mm2 (AWG)
4C × 0.75 (18)
4C × 0.75 (18)
ABUQ30GGLA1
ABUQ36GGLA1
220-240, 1, 50 220, 1, 60
220-240, 1, 50 220, 1, 60
3C × 2.5 (12)
3C × 2.5(12)
Sound Pressure Level
Piping connection
mm
950 × 834 × 330
Dimensions
60.0 (132.3)
67.0 (147.7)
Net Weight
7.80
9.20
48-7/16 × 14-31/32 × 23-7/32
48-7/16 × 14-31/32 × 23-7/32 (3 × 16 × 18) × 1
(3 × 10 × 19) × 1
(3 × 16 × 18) × 1
(3 × 16 × 18) × 1
42 / 39 / 36
46 / 44 / 42
46 / 44 / 42
46 / 44 / 42
Liquid
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 19.05 (3/4)
Drain (O.D. / I.D.)
mm
Ø 25.4 / 20.4
Ø 25.4 / 20.4
Ø 25.4 / 20.4
Ø 25.4 / 20.4
No. x mm2 (AWG)
4C × 0.75 (18)
4C × 0.75 (18)
4C × 0.75 (18)
4C × 0.75 (18)
ABUQ36LGLA1
ABUQ42LRLA1
ABUQ48LRLA1
ABUQ54LRLA1
380-415, 3, 50 380, 3, 60
380-415, 3, 50 380, 3, 60
380-415, 3, 50 380, 3, 60
380-415, 3, 50 380, 3, 60
5C × 2.5 (12)
5C × 2.5 (12)
5C × 2.5 (12)
5C × 2.5 (12)
Power Supply
950 × 834 × 330
6.00 48-7/16 × 14-31/32 × 23-7/32
dB(A)
kg (lbs)
Outdoor Unit
Wiring Connections
5.90 46-15/32 × 11-23/32 × 17-23/32
H/M/L
Power and Communication Cable (included Earth)
kg (lbs)
mm
W×H×D
Btu/h
V , Ø , Hz Power Supply Cable (included Earth) W×H×D
No. × mm2 (AWG)
950 × 834 × 330
950 × 834 × 330
950 × 834 × 330
950 × 1,380 × 330
kg (lbs)
67.0 (147.7)
67.0 (147.7)
67.0 (147.7)
96.0 (211.6) Twin Rotary
mm
Compressor
Type
-
Twin Rotary
Twin Rotary
Compressor
Type
-
Twin Rotary
Twin Rotary
Twin Rotary
Refrigerant
Type
-
R410A
R410A
Refrigerant
Type
-
R410A
R410A
R410A
R410A
Refrigerant Oil
Type
-
FVC68D
FVC68D
Refrigerant Oil
Type
-
FVC68D
FVC68D
FVC68D
FVC68D
(2 × 40 × 21) × 1
(2 × 40 × 21) × 1
Heat Exchanger
Propeller
#1_(Row × Column × Fins per inch) × No.
-
Propeller
(2 × 40 × 21) × 1
(3 × 40 × 21) × 1
(3 × 40 × 21) × 1
(3 × 33 × 21) × 1
Type
-
58 × 1
58 × 1
Propeller
Propeller
Propeller
Propeller
Air Flow Rate
m3/min × No.
BLDC
BLDC
60 × 1
60 × 1
60 × 1
55 × 2
BLDC
BLDC
BLDC
BLDC
48
52
56
56
Heat Exchanger Fan
#1_(Row × Column × Fins per inch) × No. Type
-
Air Flow Rate
m3/min × No.
Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
48
48
Liquid
Outer Dia.
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Gas
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Max.
m (ft)
50 (164.0)
50 (164.0)
Piping Connections Piping Length Maximum Height Difference
Outdoor Unit ~ Indoor Unit
Operation Range Cooling (Outdoor Temperature)
Fan Fan Motor
Type
Sound Pressure Level
Cooling
Rated
dB(A)
Liquid
Outer Dia.
mm (inch)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Piping Connections
Gas
Piping Length Max.
m (ft)
Min. ~ Max.
°CDB (°FDB)
30 (98.4)
30 (98.4)
-5 (23.0) ~ 48 (118.4)
-5 (23.0) ~ 48 (118.4)
Maximum Height Difference
Outdoor Unit ~ Indoor Unit
Operation Range Cooling (Outdoor Temperature)
Outer Dia.
mm (inch)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 19.05 (3/4)
Max.
m (ft)
50 (164.0)
50 (164.0)
50 (164.0)
50 (164.0)
Max.
m (ft)
30 (98.4)
30 (98.4)
30 (98.4)
30 (98.4)
Min. ~ Max.
°CDB (°FDB)
-5 (23.0) ~ 48 (118.4)
-5 (23.0) ~ 48 (118.4)
-5 (23.0) ~ 48 (118.4)
-5 (23.0) ~ 48 (118.4)
36 | 37