SAUDI ARABIA: THE COURTYARD BY MARRIOTT, RIYADH
It was decided that the project shall be supplied with Electrostatic Precipitator, pre-filter, bag filter and UL-certified carbon filter. Fans with AMCA certification and 200 degrees C continuous operation would be the ideal solution to meet the project specification requirements.
Advertisement
The Courtyard is a hotel owned and operated by Marriott International. As one of Marriott’s mid-priced brands, The Courtyard primarily targets business travellers and travelling families. With the quick turnover, the requirement was for reliable we ventilate in the first place. Essentially, we ventilate to:
• Secure fresh air supply for respiration and combustion processes,
• Remove emissions deriving from materials and people,
• Remove dangerous contaminants from indoor spaces, and
• Control temperature and humidity ventilation equipment, ensuring a clean, comfortable and odour-free environment.
Replacing stale “used” air with new, fresh, filtered air is essential to achieving good Indoor Air Quality (IAQ). Defined indoor air climate parameters can also only be guaranteed with a proper mechanical ventilation system. As said, an air conditioner or chiller alone does not provide any fresh air. At best, it recirculates the indoor air.
Systemair supplied the project with:
• MUB EC square duct fans,
• DVN thermo roof fans, and
• DVS direct-driven roof fans
The customer opted for Systemair solutions, as they were the most suitable and reliable fans for staircases, kitchens and toilets. Systemair showed its commitment to ensuring quick and straightforward delivery throughout the project. The solutions were also prioritised for their features, promising ease of installation, maintenance and operations.
A case for and against fresh air ventilation systems
As mentioned, there are some that voice concerns in the market concerning investment in ventilation solutions, stemming from the need for a more precise understanding of what good ventilation has to offer (see the article, titled ‘FAHUs are energy-intensive and are a cause of health issues in buildings’, December 2022 issue of Climate Control Middle East; the e-magazine is available at ccme.news).
Here are a few…
Heat, humidity and mould
The Middle East region is known for its very hot and humid climate, which leads some people to claim that in such an environment, using FAHUs can increase the humidity levels inside the building, pointing to recirculating air.
Fresh air ventilation can, in fact, help achieve relative humidity levels indoors to levels commonly recommended by academics (40-60 %), even in the Middle East’s climatic conditions. Quality fresh air ventilation and air treatment ensure the proper amount of fresh air. It also controls humidity and temperature by operating as a comprehensive and targeted supply air treatment to maintain the best possible IAQ. By bringing in dry outdoor air and removing moisture-laden indoor air, fresh air ventilation improves occupants’ comfort, reduces the risk of mould growth and other moisturerelated problems, and so much more.
Energy consumption
According to sceptics, bringing in fresh air and conditioning it to the required temperature and humidity levels require a significant amount of energy, which can increase the overall energy consumption of the building.
While it is true that fresh air conditioning requires energy, modern HVAC systems with energy-recovery components recover energy from the exhaust air and pre-cool or preheat incoming fresh air. They effectively reduce overall cooling demands, significantly reducing energy consumption while providing fresh air ventilation. Innovative solutions, like enthalpy heat exchangers or sorption rotors, also ensure efficient humidity transfer and recovery. For example, depending on the city and conditions, it is possible to upgrade a unit with an energy efficiency rating of ‘C’ or ‘D’, according to Eurovent’s Summer Energy Efficiency Class Calculation, up to a rating of ‘A’ through only integrating a sorption rotor.
Do remember in this respect that in many buildings across the Middle East, cooling energy is not recovered but merely lost to the environment.
Air quality
As we know and experience everyday, outdoor air quality in the Middle East can be poor, especially in urban areas with high pollution levels. Some people claim that bringing in fresh air from outside would introduce pollutants and allergens into the building. Others state that since the region is prone to frequent dust and sandstorms, the climate will damage FAHU systems and their components, reducing their lifespan and increasing maintenance costs.
Let’s distinguish fact from fiction here. Outdoor air pollution only underlines the need for proper ventilation to ensure optimal IAQ. Remember, the main objectives of ventilation are to introduce fresh, clean air; reduce CO2 levels and to remove particles from outdoor air as well as indoor air to achieve a proper, clean and safe environment for all types of spaces.
Fresh air ventilation can help dilute and remove indoor pollutants, such as carbon dioxide, particulate matter (PM), volatile organic compounds (VOCs) and other contaminants, providing a healthier indoor environment for occupants. Exhausting polluted air outside and bringing in fresh, well-filtered air inside reduces CO2 to minimum levels.
Comfort and compliance
Multiple studies have shown that fresh air ventilation can improve occupant comfort and productivity. By providing a more comfortable and healthier indoor environment to spaces such as offices and schools, it is possible to ensure that people are more alert, focused and productive, which benefits the economy and society as a whole.
Lastly, some building codes and standards stipulate that a certain minimum amount of fresh air ventilation is to be provided in buildings. Using fresh air ventilation in Middle East spaces ensures compliance with these codes and standards.
IAQ-centric designs
The ventilation system must be designed with great care to achieve the required thermal and atmospheric indoor environment. An FAHU must be equipped with the necessary functions for air handling – such as high-level filtration, energy-recovery components, integrated controls – with the required capacity.
The air distribution system must be designed considering sound levels, air velocities and the air volume requirements in the respective rooms. If a clear focus on energy efficiency is
OMAN: MANDARIN ORIENTAL MUSCAT

Systemair delivers ecology units to the hotel to ensure the kitchen is able to maintain a clean and healthy indoor climate, in line with the establishment’s hospitality standards
The Shatti Al Qurum Hotel, also known as Mandarin Oriental Muscat, is a luxury development project, 20 minutes from Muscat International Airport. The main requirement was a ventilation system to help ensure the hygiene and cleanliness of the kitchens within the facilities. The customer highlighted the need to clean greasy and dirty kitchen exhaust air, including Electrostatic Precipitator, pre-filter, bag filter and carbon filter and the motor out of air stream ecology units.

Energy efficiency was also a key priority for the customer to ensure long-term sustainability of operations whilst remaining durable to meet the kitchen’s heavy use.
It was decided that the project shall be supplied with Electrostatic maintained for all design aspects, a balanced, demand-controlled mechanical ventilation system with energy recovery will be the most efficient way of achieving an excellent indoor air climate.
It is also important to remember that the factors for “correct” design will also vary depending on:
• Building size, category and type,
• Occupancy,
• Indoor activities,
• Contamination sources and concentrations,
Precipitator, pre-filter, bag filter and UL-certified carbon filter. Fans with AMCA certification and 200 degrees C continuous operation would be the ideal solution to meet the project specification requirements.
The following model sizes were chosen:
• SYSECO 150,
• SYSECO 50, and
• SYSECO 30
The units, delivered with the support of Systemair’s Oman distributor, M/S. Light House Trading & Engineering Services LLC., IE2 models were delivered, as they met the client’s efficiency requirements. The units play a vital role in maintaining IAQ, which is crucial in environments where grease, smoke and odour particles, emitted from cooking, negatively affect human health and impact comfort conditions in homes, restaurants, hotels, and other sensitive hospitality and entertainment venues.
• Building location, and
• Climate
For ordinary comfort ventilation, the goal is to achieve an excellent thermal and atmospheric indoor environment with a “tolerable” percentage of dissatisfied occupants. People vary regarding temperature preferences, activity level and clothing. Therefore, achieving 100% satisfaction in any given thermal environment is impossible.