F-305B Ultrasonic Massage & Galvanic Machine

Page 1

USER GUIDE Model F�305B

Ultrasonic Massage & Galvanic Machine


PREFACE Congratulations and thank you for purchasing the F-302/5B Ultrasound massage and Galvanic machine. Your choice of machine is a reliable, safe and easy to use piece of professional salon equipment. The F-302/5B is designed for multi-purpose treatment use, only by trained beauty or medical professionals. Although the machine is designed for various (types of) treatment use, it must never be used for any purpose other than its intended design limitations, or by any person unqualified to do so, as per your local or national legislation requirements. It is important that you read and retain this user guide for future reference. Should you need to contact us regarding your purchase of this product at a future date, please make a note (in the space below) of the following information upon arrival, as this information will expedite any communication you may have with us.

SALON NAME _________________________________________________________________

FULL NAME OF PURCHASER __________________________________________________

MODEL OF EQUIPMENT ____________

F-302/5B______________________ ________

DATE OF PURCHASE ___________________________________________________________

INVOICE NUMBER ______________________________________________________________

Contact details Tel

0(044) 1322 290101

Fax 0(044) 1322 290011 Email info@cosmetronic.com


USER GUIDE FOR THE F-305B

Ultrasound & Galvanic Unit . A brief introduction to the machine control panels Front panel:

A. Ultrasound Eye LED (active when lit) B. Ultrasound Function LED (activity Indicator) C. Ultrasound Pulse ‘waveform’ LED (active when lit) D. Ultrasound Function Power Switch (main on/off) E. Ultrasound Function Selector (eye or face active when lit) F. Ultrasound Waveform Selector (pulse or continuous) G. Ultrasound Face LED (active when lit) H. Ultrasound Continuous ‘waveform’ LED (active when lit) I. Ultrasound Intensity Dial (to increase or decrease output energy) J. Galvanic ‘Negative’ polarity LED (active when lit) K. Galvanic ‘Power on’ LED (active when lit) L. Galvanic Polarity Selector Button M. Galvanic Main Power Button (on/off) N. Galvanic ‘Positive’ polarity LED (active when lit) O. Galvanic Intensity Dial (to increase or decrease output energy)


A brief introduction to the back panel Machine inputs/outputs

Back Panel: A. Ultrasound face probe socket B. Ultrasonic eye probe socket C. Galvanic probes socket D. Three-Pin ‘loop’ output socket (if stacking more machines) E. Mains power supply inlet plug socket F. Mains supply On/Off power switch G. Two-Pin output socket (for connecting optional lamp) H. Mains inline fuse holder

Ultrasonic massage An ultrasonic wave (with a frequency higher than 20,000Hz) is a form of ‘sound vibration’ that is inaudible to human hearing. This ‘ultrasound’ may be used on the dermis and epidermis with a wide range of beneficial results. Its main use is prescribed product penetration, where the products are introduced to the tissue with ultrasonic waves. It increases both the uniformity and penetration delivery of prescribed products into the tissue and increase’s its therapeutic effect of the prescribed product accordingly. In the course of ultrasonic therapy, the intensity of the ultrasound is generally between 0.5-1.5W/cm2 (shown on the LED display between the Green & Yellow sections), with a treatment duration of round 10-15 minutes.


1. Mechanica M al function n An ultrasonic wave acts on the body in the fo ollowing way. By stim mulating the body cells and the tiny ge it produces. Expan nsion deve elops within n the space in which the cells exist, e causing miccro-massag movvement of the cytopla asm, the ro otation of mitochondr m ria, and the e vibration of the cell nucleus; which stimulattes and exxpands the cell memb brane. It im mproves loccal blood a and lymph circulation c and also o increasess the pene etration dep pth of prescribed products, and d thus theirr effectiven ness. Ultrrasound alsso helps to o improve the t metabo olism and regeneratio r on of bodyy cells.

2. Warming W a and heatin ng function The e warming and heatin ng action of o ultrasoun nd is one of o its most important ttherapeutic c factors. It iss a kind of internal i he eat, with a temperatur t re increase e of approxx 80%. Thiis heat is dissipated d b by the blood circulation and d is not feltt by the clie ent. This warming w acction can change the blood circculation and d helps to reduce inflammation n of the derrmis. It is of o great ben nefit prior to t plastic surg gery to red duce swelling, and affter the hea aling proce ess has pro ogressed. It is useful in reducing posst surgery puffiness p a scarring. It produces a relax and xing and comforting effect for the client. 3. Chemical C f function The e biochemical function of ultraso ound come es from the e reaction to anabolissm and catabolism. Ana abolism – The proce ess that co onverts sub bstances in nto other co omponentss of the org ganisms che emical struccture. abolic proccess by which cells co onvert sub bstances in nto excreted compoun nds. Cattabolism – The meta i.e. the processs of cell metabolism m m. Small do oses of ultra asound tre eatments ccan help promote the synthesis of proteins p witthin the cells, which can c help to o regenera ate damage ed or woun nded tissue e, thuss promoting the synth hesis of fib bre cells in the body. In the proccess of anabolism an nd cataboliism, the prescribed d product is absorbed d and utilizzed by the cells. The accelerate ed metabolism of the e cells, changess the PH le evel of the skin to an increased alkaline state, which h facilitates s greater abssorption of the prescrribed produ ucts. The skin s lighten ns and is viisibly smoo other, whic ch means this t proccess is parrticularly efffective witth whitenin ng/lightenin ng productss used for all types of o pigmenta ation prob blems. 4. Benefits B • Crreates hea at and warm mth which will relax tiissue and muscles • Brreaks down n molecula ar structure e of prescriibed produ ucts, aiding g penetratio on and abs sorption • Re educes sw welling and puffiness • He elps to smo ooth and soften s fine lines and wrinkles w


Benefits Continued• Exfoliates the top layer of the skin • Improves blood circulation • Increases cellular regeneration • Has a healing and regenerative effect on wounds and inflamed tissue • Increases the moisture retention of the skin • Softens the thrombus (any blood clots within a vessel that partially or totally obstructs circulation.) • Improves acneic skin and reduces pore size • Gives the skin a healthy glow 5. Caution (during use) • Never use on dry skin. A medium must always be applied • Do not use on the stomach area of pregnant women • Do not use on people with pacemakers (any electrical or rhythmic heart regulating device) • Do not use on people with known heart conditions • Always use ultrasonic electrodes with sufficient media (moisturiser or serum on the skin) • Ultrasonic treatment is suitable for all skin types – the massage time and machine settings are varied for each of the different skin types. • For sensitive skins – reduce the treatment time to ‘3-5min’ and ensure the power setting is at its lowest level to start with. 6. Combining ultrasound treatments Ultrasonic exfoliation lends itself perfectly as an after treatment for micro-dermabrasion, glycolic and other peels. It removes dead cells and any leftover crystals, better than most cleansing techniques. You can help to speed up the healing and rejuvenation process of your client’s skin, by inducing water soluble products into the client’s skin with ultrasound after you have completed the cleansing process.

Treatment

(product penetration)

. The treatment of using both ultrasound & cosmetic products consists of, (a) the intensity of the ultrasonic wave, (b) the period of treatment and (c) course of treatment length. Points for attention during the course of the treatment are that the intensity for facial massage should be controlled between 0.5-1.25W/cm2 . . The period of the treatment for the entire face is generally between 5 and 15 minutes per treatment. However, prolonging each treatment will not multiply or improve its effectiveness. . The course length may be decided according to different skin conditions: acne 3-5 times, chronic issues, such as pigmentation or hyper-pigmentation, scars, acne rosacea, darkened eye-rim, eye bags, wrinkles etc, once every 2-3 days. One course usually consists of 10 sessions. Preventative treatment: 1 or 2 times every week. If the patient’s condition worsens during the specific treatment course, reduce the frequency of treatment (extend intervals between treatment) or reduce the intensity and extend the course of treatment. The interval between the each treatment should be 1-2 weeks. If the treatment required is over 3-4 courses, then the interval between treatments may be prolonged after the second treatment session. . The ultrasonic massage instrument has two kinds of wave state. The first is a ‘successive’ (continuous) wave , and the second is a ‘pulse’ (intermittent) wave.


The first is a continuous ultrasound wave; whose intensity has a remarkably beneficial effect on the skin. The second is an intermittent (short) pulsing of ultrasound waves which lasts for a tiny fraction of a second. Therefore the important characteristic’s of these ‘pulse’ waves is that, the heat generated is markedly reduced, so that the ‘mechanical action’ of the ultrasound wave can be brought into full effect without client discomfort. The choice of wave state is as follows: generally, the pulse (intermittent wave form) state is used for the inflamed tissue areas (redness etc.) or for use on dilated capillaries, while the continuous (constant wave form) state is suitable for all other treatment types.

. Method Ultrasonic treatment utilises direct ‘touching’ radiation. During the treatment, the ultrasonic head must be pressed against the surface of the skin. Please note a suitable conductive agent (prescribed product) should always be used between the ultrasound head and the skin. Never use on dry skin only. The ultrasound head (generator) should be gently and slowly moved over the treatment area in circular or linear (back and forth) motion, dependant on the size of area being treated.

. Steps 1. Before treatment, cleanse/tone the treatment area with the prescribed skin type products. 2. Remove any product residue prior to steaming the face for 10 minutes. 3. Cleanse the treatment area again to remove any dirt or debris on the face (milia/porous secretions etc) so as to prevent the ultrasonic waves from pushing it back into the skin. 4. Gently tone over every part of the face (or treatment area) with the correct astringent. 5. After wiping off the astringent, the skin will be thoroughly cleansed for optimum protection. 6. After analysis of the face, carefully select the suitably prescribed product. 7. Apply a sufficient amount of prescribed product to the treatment area. 8. Plug in the machine to the mains and power up the unit. Push the “POWER” button and select the “ULTRASONIC” function; then adjust the intensity of the ‘output’ according to “U/Energy” LED display, generally in the green and the yellow section. Output may vary with skin quality, age, and tolerance of the patient. 9. Select the desired wave state, successive (continuous) wave ( ), or pulse wave ( ) according to the chosen treatment, by switching the “STATE” button. 10. Hold the ultrasonic probe firmly and begin to massage the treatment area to which the prescribed product has been applied. Treatment time should vary dependant on the size of the treatment area in question. A standard (whole) facial area should take 10-15 mins of repetitive massage. 11. Wash and sterilise the ultrasonic head after each and every treatment.

. Notes 2. Always cleanse before treatment. 3. Always ensure adequate product is applied for 15 mins of treatment. 4. The heat output of the ultrasound generator corresponds directly to the power output selected. Generally, lower output is used in facials and higher output for body treatments. Always confirm client comfort to ensure that the output (temperature) is not ‘too high’. 5. If the treatment area is small or sensitive, use the ‘eye’ probe and ensure the energy output should be limited between 0.5-0.75W/cm (the green LED’s on the “ENERGY” display). The treatment time may be reduced to 8-10minutes.


6. A treatment course is generally around 10 sessions in total, with a minimum rest period of 1 day between sessions. If other facial treatments are being conducted to the same area, a minimum rest period of 7 days should be observed between treatments. 7. If the ultrasound generator of choice does not appear to have an output, please check that the correct probe & output socket for the chosen treatment has been selected. 8. The ultrasound probes should be cleaned with clean water (not hot) using a clean soft cloth and then chemically sterilised using the appropriate sterilisation fluid. Dry the probe carefully after sterilisng and store safely in its holder on the trolley in between uses. NOTE: - do not immerse the probe in any fluid! Always sterilize the probes again prior to use with a ‘steri-wipe’ type product of your choice.

. CAUTION (during use) 1. Do not leave any of the ultrasound probes turned on whilst unattended, otherwise ‘over heating’ will occur and this may result in damage to the probe or reduction of its working lifespan. 2. Do not attempt to separate the stainless steel generator from its rubber holder (handle), any attempt to do so, may cause irreparable damage to the generator. Do not attempt to open any attachment or machine. The machine and attachments have no user changeable parts. All items should be returned to your purchasing agent or authorised repair centre

GALVANIC . Contra-indications • Pacemaker (any electrical or rhythmic heart regulating device) • Pregnancy • Thrombosis/Phlebitis • Skin diseases • Operations (within last 6 months) • Silicone implants • Hypersensitive or vascular skins

. Iono theory The galvanic current is a constant and direct current (D.C.) rectified to a safe low – voltage level. This direct current flows in one direction only and has adjustable polarity. When current is flowing, one electrode will always be negatively charged and the other positively. Chemical changes are produced when this current is passed through certain solutions containing acids and salts. Chemical effects are also produced when a galvanic current is passed through the tissue and fluids of the body. The Galvanic machine: The galvanic machine has two important functions during a facial treatment. Its main function is to introduce water soluble products into the skin, and this process is called ionophoresis. When using a galvanic current, there are two poles with a selective negative (-) or positive (+) polarity output to choose from. Positive pole (ANODE) and Negative pole (CATHODE) • Produces acid reaction • Produces alkaline reaction • Soothes nerves • Stimulates nerves • Decreases blood supply • Increases blood supply • Hardens tissue • Softens tissue


The positive pole may be used: • To close the follicles (pores) after the facial treatment • To decrease redness, as in mild acne. • To prevent inflammation after comedone and blemish treatment • To force acid pH solutions, such as astringent, into the skin. The negative pole may be used for the following conditions: • To stimulate the circulation of blood to dry skin. • To force desincrustation lotion (alkaline pH solution) into the skin. Do not use the galvanic current over an area with any broken capillaries.

Desincrustation: describes a process that softens and liquefies grease deposits which are accumulations of sebum in the follicles. This sebum is usually filled with dead cells, makeup and grease. In order to do a desincrustation treatment, an alkaline solution is used to penetrate the follicle and dissolve the debris. It is important to remove all traces of massage cream and cleanser from the skin before starting the desincrustation treatment, as any residual desincrusation lotion will emulsify the products and may force them into the follicles.

Ionisation: is the forcing of a solution or cream into the skin. The ions of electricity from the positive pole will pass through a moisturising cream or lotion that has been applied to the client’s face and assure deeper penetration of the product into the skin. In order for the ionisation to work properly, the cream or lotion applied to the face must be water soluble (o/w), such as moisturiser or ‘vanishing’ type cream. Heavy creams that do not dissolve in water (w/o) and leave an oily film on the skin will not penetrated due to their larger molecular structure.

. Method . Connect the required galvanic probes (roller or ball) to the output lead which is inserted in the galvanic output socket on the rear of the machine. Ensure this is done prior to switching on or powering up the machine. The client then holds the metal pole (where present), and the therapist holds the handle of the roller. . Changing polarity of the probes is done by adjusting leading in (+R) and leading out (-G) button. The treatment area must be cleansed and dried before penetrating any products into the tissue. Turn the electrode button to (+R). Now the probes are positive, whilst the indifferent pole is negative. You can then introduce the chosen product to the treatment area. You may then cover the probe (or face) with a piece of cotton or sponge that has your product on it, or you may use directly, with the probe onto the skins surface which is generously covered with the desired product. Whilst doing desincrustation, you should change the electrode polarity button to (-G), now the probe is negative while the indifferent pole is positive. Cover the probe with a piece of cotton or sponge that has been soaked in the alkaline solution (chosen astringent) before doing this treatment. This is done to balance the skin PH and aid in the breakdown and removal of debris & grease/oil from the skin.

NB: ‘+ & R’ refers to positive and ‘R’ red LED whilst ‘- & G’ refers to negative and ‘G’ Green LED. . Power on “IONOS”, select the operational polarity for the treatment (+ or -), then turn the “I/Energy” level to the minimum. Touch the treatment area with the probes, then slowly adjust the “I/Energy” level to appropriate intensity (usually to the point just before the client feels a mild tingling sensation). Smoothly slide the chosen probes over the treatment area. NB: When using a cotton or linen with the probes (or as a shroud) it should be noted that, the more moisture on the cotton or linen pads/mask, the more effective the treatment will be.


General notes It should be noted that your F-305B series machine is CE approved and only for use by competent or qualified professionals, as per your required regional or country legislation currently in effect. It is recommended that you should annually have your unit checked (PAT tested or equivalent) by a competent technician to ensure continued safe working practices. We recommend that you regularly (minimum of once weekly) inspect all trailing leads and power cables to ensure no accidental damage has occurred during use. By being proactive it this matter, you will help to continue the safe use and longevity of your work station unit and accessories. We recommend that when not in use, your work station has all cables and attachments securely stowed on the trolley unit and were possible, to prevent tripping hazards, and that the unit is stored in a suitable location to prevent accidental damage by other items of salon furniture and equipment. Your F-305B is covered by its manufacturing warranty, against component or material defects and should you encounter any user issues, you should unplug the machine from the mains power supply and immediately contact your sales agent/supplier for further advice. Do not use your machine if you are unsure of any of its operations or features, to prevent any accidental damage or injury. Never under any circumstances try to open or inspect the machines or its accessories. Should an inspection of any item be required, you should contact your supplier or a suitably competent technician to do so. There are no user serviceable parts with your F-305B series Machine. Any repairs or alterations made to your F-305B series machine by unauthorized persons will invalidate your manufacturer’s warranty and will render you liable in full for the cost of any repairs, whether covered by the original warranty period or not. Any machines that are returned and not bearing the original manufacturer’s serial numbers will invalidate their warranty. Where the manufactures warranty has been invalidated for whatsoever reason, any repair costs incurred will be chargeable in full. This will include making ‘whole’ any returned items missing their originally supplied attachments, which will then be charged at the applicable retail rates.


Warranty Procedure 1 - The warranty on all Cosmetronic equipment is 12 months from the date of invoice and covers the products against defects in materials and workmanship or component defect (Unless superseded by an extended warranty agreement). This warranty is non transferable and applies to the original purchaser only. 2 - No product repairs or component replacement will take place unless all/any amounts owed to Cosmetronic for the said goods have been paid for in full, prior to any repairs. 3 - All extended warranty policies must be paid in full prior to dispatch of goods and will extend the above cover (No 1) by a further 2 or 4 years, to a maximum of 5 years including the first free year. 4 - Before returning any product to Cosmetronic UK Ltd for repair or replacement you must first: - Endeavour to establish cause of product fault (e.g.. check fuses etc.). - Notify Cosmetronic of any fault development within 24 hrs of its occurrence. - Contact a member of our technical service dept (95% of faults can be rectified over the telephone). - Obtain an RMA (return material authorisation) from a member of Cosmetronic. - Package the goods to include all parts or accessories received with that item. - Any item received incomplete for repair will be made complete and all relevant parts/accessories charges will be added to the repair cost. - Pack the goods to be returned in sufficient packaging as to prevent any damage occurring in transit, as Cosmetronic will not be held liable for damage to products due to insufficient packaging.

5 - All goods returned to Cosmetronic without the correct RMA authorisation will be refused. 6 - No goods will automatically be replaced, when the faulty item can be repaired within a reasonable time span (except items deemed unserviceable on arrival). Goods will be replaced at the discretion of Cosmetronic when it is deemed that all/any goods are beyond economic repair. Items of loan equipment may be given at the discretion of the management and subject to delivery/collection charges, together with a refundable deposit. 7 - Cosmetronic will not be held liable for any momentary lack of stock, or technical resource, or any other circumstance beyond its control that may delay any component replacement or repair. Cosmetronic will not be held liable for any special, incidental, consequential damages resulting from a breach of warranty, or under any other legal theory, including but not limited to loss of profit or good will, downtime, damage to or any products, treatments used in conjunction with its products. Purchase implies your acceptance of Cosmetronic terms & conditions. 8 - When our service department cannot determine any fault or malfunction with the goods returned, you may be liable for any administration and testing costs. 8a- When goods returned are not in a merchantable (dirty or unhygienic) condition, they will be made to merchantable quality again, and cleaning costs will be charged where necessary. 9 - All goods returned will be at the owner’s risk. Cosmetronic will not be held liable for any damage or loss to goods whilst in transit. 10 - Carriage costs are at the owner’s expense for all collection & return freight costs. All goods will be carried via Cosmetronic nominated couriers unless specified and their terms & conditions of carriage will apply and be accepted by you on application of your collection/delivery request . Any goods in transit insurance required must be requested prior to collection/dispatch. 11 - No repaired goods will be released until any costs relevant to that repair (unless under warranty) have been settled in full, this will include all carriage/freight costs. 12 - Call out/on-site repairs will be carried out as soon as is physically possible and charged at a cost of £ POA. The charge is based on the original delivery address of the product when purchased. This charge is payable in full, prior to any on site attendance. This charge will not include travel expenses (fuel, parking, toll charges etc.) but, will include labour and the parts replacement of electrical or motorised mechanical components, to include electrical motors, foot control boxes, system control boxes but does not include optional extras such as Vibro or Thermo heat functions. The call out repair charge will not cover items deemed as natural “wear & tear” such as upholstery etc. The call out charge will not cover damage by accident, misuse, or misapplication, or if the product has been modified without permission. Any serial numbers removed or displaced will also result in warranty invalidation. Proof of purchase will be required before any repairs carried out. 13 - Warranty call out/ on-site repairs, will be charged (POA), but will be refunded once any warranty claim is validated.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.